FIREPLACE & CHIMNEY COMPONENT SPECIFICATIONS
PERFECTVIEW 33LDVT TOP VENT
578mm
908mm
152mm
368mm
356mm
851mm
806mm
733mm
753mm
794mm
838mm
466mm
51mm
118mm
86mm
162mm
162mm
225mm
118mm
VENT SECTIONS and OFFSETTING ELBOWS
64"
1626mm
48"
1219mm
36"
914mm
7"
178mm
35"
889mm
18"
457mm
24"
610mm
12"
305mm
12"
305mm
8"
203mm
7TDVP24
7TDVP36
7TDVP48
7TDVP8
7TDVP1218
7TDVP3564
7TDVP12
NOTE: THE INSTALLED LENGTH OF ANY VENTING SECTION IS 11/2” LESS THAN ITS TOTAL
LENGTH, EXCEPT FOR THE LAST SECTION INSTALLED.
Download from Www.Somanuals.com. All Manuals Search And Download.
CONTEMPORARY TERMINATIONS
FIREPLACE FACTS
9³⁄₄"
PerfectView 33LDVT
33” PerfectView Direct Vent Gas Appliance
32"
813mm
FEATURES:
12¹³⁄₁₆"
7"
• 33 PerfectView Direct Vent Gas Appliance
”
• 11,200 to 16,000 BTU/hr. input
• Patented Insta-Flame TM Ceramic Burner System with 4-piece
Split Oak Ceramic Fiber Log Set
• Tempered Glass Panel Assembly
• Adjustable Flame and Heat Output
• Wall Switch
5"
165
127mm
61/2"
16"
19"
mm
406mm
13³⁄₁₆"
• 18 Flex Connector with Shutoff and EB1 electrical box installed
”
• Wall Firestop, Zero Clearance Sleeve (Rear vent models only)
• Rated as Fireplace Heater (AFUE)
• Uses 4”/7” Majestic (Direct Vent) Venting Components.
482mm
9¹⁄₂"
7TDVSKS
BURNER SYSTEM:
• Capacity
– Natural:
– Propane:
• Fuel - Natural or Propane Gas
16,000 BTU/HR Max.
11,200 BTU/HR Min.
16,000 BTU/HR Max.
12,000 BTU/HR Min.
7"
7TDVSKV
• Ignition System - Standing Pilot With Piezo Ignitor, A Low Voltage,
Self-Generating Power Pile System (mV)
– No Outside Electrical Power Needed OR
ELBOWS
– Electronic ignition that requires 120 VAC Electrical hook up
• Gas Supply Line - Consult Gas Code Book for Correct Sizing
• Gas Inlet and Manifold Pressures
7"
OFFSET w/2-90°
178mm
Back to Back
91/4"
Natural
5.5” w.c.
14” w.c.
3.5” w.c.
Propane
11.0” w.c.
14.0” w.c.
10.0” w.c.
335mm
17
"
Minimum Inlet Pressure
Maximum Inlet Pressure
Manifold Pressure
OFFSET
71/4"
184mm
90°
91/4"
13"
330mm
235mm
13"
MINIMUM FLOOR AREA:
330mm
• 33” W X 14” D
235mm
91/4"
71/4"
184mm
HEARTH EXTENSION:
A Hearth Extension Is Recommended But Not Required
90°
13"
330mm
ACCESSORIES:
33LDVTCR - 33” LDV Ceramic Refractory - Top
FP889
FK12
FK24
IMTFK
- Fan and Cord (160cfm) (for RN/RP only)
- Variable Speed Heat-Activated Fan Kit
- IMT Thermostat w/ Face Kit
7TDVRT90
45°
OFFSET w/2-45°
Back to Back
73/8"
Minimum Mantel Clearances
45°
Clearance From Top
of Combustion Chamber Opening
To Bottom of Mantel
Mantel Depth
188mm
45°
8
1/2”
2”
4”
6”
8”
10”
10 1/2”
12 1/2”
14 1/2”
16 1/2”
11"
73/8"
188mm
73/8"
188mm
The Fireplace Facts Information Sheets are for
quick reference only and are subject to change with-
out notice. Actual fireplace instructions must abide
by specifications provided with each product.
7TDV45
FP890
REV. 10/07
Download from Www.Somanuals.com. All Manuals Search And Download.
|