Vent a Hood Ventilation Hood SLH6 K User Manual

Read and Save These Instructions  
All Hoods Must Be Installed By A Qualified Installer  
INSTALLATION INSTRUCTIONS  
SLH6-K UNDER CABINET HOOD  
Read All Instructions Thoroughly Before Beginning Installation  
WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK,  
OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:  
A. Installation work and electrical wiring must be done by qualified  
person(s) in accordance with all applicable codes and standards,  
including fire-rated construction. Switch power off at service panel  
and lock the service disconnecting means to prevent power from  
being switched on accidentally during installation.  
B. When cutting or drilling into wall or ceiling, do not damage  
electrical wiring and other hidden utilities.  
C. Ducted fans must always be vented to the outdoors.  
D. Sufficient air is needed for proper combustion and exhausting of  
gases through the flue (chimney) of fuel burning equipment to  
prevent back drafting. Follow the heating equipment  
manufacturer’s guideline and safety standards such as those  
published by the National Fire Protection Association (NFPA), and  
the American Society for Heating, Refrigeration and Air  
Conditioning Engineers (ASHRAE), and local code authorities.  
WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL  
DUCTWORK  
U
Page 1  
(Rev. 04/08)  
C
US  
R
L
L114A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation Details  
1) Read all instructions thoroughly before beginning installation.  
2) When installing the SLH6-K under cabinet hood, it is recommended that the bottom edge of the hood be located no  
more than 21” - 24” from the cooking surface. Exceeding recommended mounting height may compromise performance.  
Soffit  
Cabinets  
6”  
21”-24”  
36”  
3) Inspect the underside of the cabinet for a flush mounting surface. If the underside of the cabinet is recessed, install  
wood strips to provide a flush surface for the hood mounting screws to engage.  
4) Determine whether the hood will discharge horizontally or vertically. The hood is shipped to discharge vertically but is  
easily converted to horizontal discharge by exchanging the discharge adapter on top of the hood (4 screws) with the  
discharge cover on the back of the hood (2 screws). Use duct tape to seal the discharge adapter and discharge cover  
to the hood.  
5) IF THE HOOD IS TO BE “BACK VENTED”, PROCEED DIRECTLY TO STEP 6.  
Install the duct from the outside of the home down to the location of the hood exhaust outlet allowing room for the  
VP521 transition on the top of the hood (if applicable). If a VP521 transition is used, install the duct down to the location  
of the transition outlet plus 1”. This will allow the transition to engage 1” inside of the duct. Consult the connection  
diagram (below) for further details on exhaust outlet placement.  
Use duct tape to seal all joints. A complete listing of available Vent-A-Hood ducting materials is provided on the back  
page of this instruction sheet.  
Transition height: 3 1/4” x 10” duct will connect directly to the exhaust outlet of the hood. Optional VP521 transition to  
7” round (sold separately) is 7 1/2” tall.  
Ceiling Cutout for Vertical Ducting  
Viewed from Above  
7⁄8"  
2 5⁄8"  
Back of Cabinet  
3 ½"  
5 1⁄8"  
5 1⁄8"  
6 ¼"  
Electrical  
C
L
Page 3  
(Rev. 04/08)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
L114A  
Installation Details Continued  
6) Remove the hood from its packaging and place on the floor or countertop in front of the cabinet where it will hang.  
Warning: Make sure power is off and locked at the service disconnecting  
means on the service panel during installation.  
7) Determine whether the electrical wire will enter from the top or the back of the hood. Remove the electrical enclosure  
cover (1 screw) and the top or back electrical enclosure knockout from the hood. Install an appropriate 1/2” UL listed  
electrical wire clamp through the electrical knockout. Install electrical wiring from the electrical panel to the hood  
location.  
CFM  
CFM  
CFM  
CFM  
Minimum Round Square  
Model  
K250 (Top Vent - High)  
Volts  
Amps  
RPM  
Equivalent CFM#  
Duct Size  
Inches  
115  
115  
115  
115  
3.2  
3.2  
3.2  
3.2  
1550  
1200  
1550  
1200  
240  
170  
220  
175  
360  
255  
330  
265  
225  
170  
215  
170  
215  
160  
195  
160  
200  
155  
180  
145  
7” (or equivalent)  
7” (or equivalent)  
7” (or equivalent)  
7” (or equivalent)  
38  
38  
38  
38  
K250 (Top Vent - Low)  
K250 (Back Vent - High)  
K250 (Back Vent - Low)  
All K-Series hoods have two halogen lights.  
Because the Magic Lung® uses centrifugal filtration rather than conventional baffle or mesh filters, the Magic Lung® blower can handle cooking equipment with higher cubic feet per minute (CFM) requirements and can deliver equivalent CFM much more efficiently  
than other filtration systems. When comparing the Magic Lung® with other blower units made by other manufacturers, use the “Equivalent CFM”.  
#
8) Insert the electrical wire through the electrical wire clamp allowing 3” - 4” of wire inside the enclosure for hookup.  
Tighten the electrical wire clamp.  
9) From inside the hood, using UL listed wire nuts, attach the “neutral” wire to the white lead, the “hot” wire to the black  
lead, and the ground wire to the green lead inside the junction box. Replace the electrical cover previously removed in  
Step 7.  
Warning: Do not operate hood without proper ground connection.  
10) FOR BACK VENTING APPLICATIONS ONLY. IF YOU ARE NOT BACK VENTING, PROCEED DIRECTLY TO STEP 12.  
Note: Wall studs may interfere with back venting installations.  
Additional framing may be required. It is necessary to cut a  
duct access hole in the wall prior to installing the hood. Starting  
2 1/8” above the bottom edge of the hood, cut a hole 3 1/2”  
Wall Cutout for Horizontal Ducting  
Viewed from Front  
3⁄8"  
high x 10 1/4” wide (see diagram at right).  
1 1⁄8"  
Bottom of  
Cabinet  
11) Install the duct from the outside of the home to the duct access  
hole in the wall. Where possible, use duct tape to seal joints.  
3 ½"  
12) While aligning the duct and guiding the wires, position the  
hood under the cabinet. The duct should connect together as  
the hood is located in place. Note: Unless using the VP521  
transition, the duct work must fit inside the exhaust collar. If  
using the VP521, 7” round duct should be placed with the non-  
crimped end on the outside of the collar of the VP521 exhaust  
outlet. Using the four screws provided, attach the hood to the  
bottom of the cabinet.  
Electrical  
5 1⁄8"  
5 1⁄8"  
6 ¼"  
C
L
14) Refer to the Owner Maintenance Guide Operating Instructions for proper hood operation. Test all blower and light  
functions to ensure they are operating properly.  
Page 4  
L114A  
(Rev. 04/08)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VENTING CCESSORIES  
A
WALL LOUVER  
WALL LOUVER  
WALL LOUVER  
RECTANGULAR WALL LOUVER  
8 5⁄8”  
13”  
11”  
8 ½”  
10”  
Back  
View  
Back  
View  
Back  
View  
6”  
7”  
8”  
11”  
3 ¼”  
13”  
6”  
FLANGE  
2”  
1 ½Flange  
1 ½Flange  
1 ½Flange  
FLANGE  
½”  
1
MODEL  
VP526  
VP527  
DIM  
MODEL  
VP554  
DIM  
MODEL  
VP555  
DIM  
MODEL  
DIM  
6Round  
10Round  
12Round  
VP538  
6x 8 ½“  
7Round  
VP560  
3 ¼x 10”  
VP528  
8Round  
LOW PROFILE ROOF JACK  
LOW PROFILE ROOF JACK  
ADJUSTABLE ELBOW  
BACK/SIDE VENT ELBOW  
(MAXIMUM 4/12 PITCH)  
(MAXIMUM 4/12 PITCH)  
12”  
8 ½”  
6”  
7”  
8”  
VP513 - 8 ½”  
VP514 - 9 916”  
VP515 - 10 5⁄8”  
6”  
16 ¾”  
6 ½”  
10 ½”  
22 ½”  
16”  
16 ¾”  
20 ¾”  
8Round  
MODEL  
VP539  
VP540  
DIM  
MODEL  
VP552  
VP553  
DIM  
MODEL  
DIM  
MODEL  
DIM  
6Round  
7Round  
8Round  
10Round  
VP513  
6Round  
7Round  
8Round  
VP561  
8to 6x 8 ½”  
12Round  
VP514  
VP515  
VP541  
3 ¼x 10BACK VENT ELBOW  
MULTI-BLOWER TRANSITION  
“Y”TRANSITION  
3 ¼x 10”TO 7”TRANSITION  
10”  
10”  
7”  
14”  
12”  
12”  
3 ¼”  
VP562 - 17 ½”  
VP563 - 16 ½”  
7 ½”  
18”  
4 ¼”  
10”  
3 ¼”  
VP562 - 23 ¼”  
VP563 - 30 ½”  
10”  
3 ¼”  
MODEL  
VP559  
DIM  
MODEL  
DIM  
MODEL  
DIM  
MODEL  
DIM  
3 ¼x 10”  
VP562  
6& 8to 10”  
VP517  
8& 8to 12”  
6& 8to 12”  
6& 8to 10”  
VP521  
3 ¼x 10to 7”  
VP563  
8& 8to 12”  
VP518  
VP551  
OFFSET KIT - ROUND  
OFFSET KIT - RECTANGULAR  
STANDARD ISLAND TRANSITION CLUSTER BLOWER TRANSITION  
12”  
8”  
3 ¼”  
7”  
10”  
9”  
10 ½”  
11”  
11”  
11”  
11 ¼”  
6”  
16”  
16”  
6”  
16”  
5”  
18 ½”  
MODEL  
VP529  
DIM  
6Rnd to 7Rnd  
MODEL  
VP550  
DIM  
6Rnd to 3 ¼x 10”  
MODEL  
VP565  
DIM  
MODEL  
VP564  
DIM  
8& 8to 12”  
5x 16to 8”  
OFFSET L & R TRANSITION  
SIDE VENT TRANSITION L & R  
FOR ISLAND BLOWERS  
19”  
6& 8COLLAR  
6x 8 ½COLLAR  
FOR ISLAND BLOWERS  
8”  
6Dia.  
8Dia.  
2Larger  
Than Cutout  
6x 8 ½”  
Opening  
9”  
8”  
12”  
16”  
2Larger  
Than Cutout  
16”  
5”  
5”  
11 ½”  
MODEL  
VP542  
VP543  
DIM  
MODEL  
VP544  
VP545  
DIM  
MODEL  
DIM  
MODEL  
VP537  
DIM  
Top Left  
Left Side  
VP533  
VP535  
6Round  
6x 8 ½”  
Top Right  
Right Side  
8Round  
ROUND DUCT PIPE  
3 ¼RECTANGULAR DUCT PIPE  
6RECTANGULAR DUCT PIPE  
6”  
7”  
8”  
3 ¼”  
6”  
10”  
12”  
30”  
½”  
8
16”  
36”  
24”  
MODEL  
VP500  
VP501  
DIM  
MODEL  
VP504  
VP505  
VP506  
DIM  
MODEL  
DIM  
6Round  
3 ¼x 10”  
3 ¼x 12”  
3 ¼x 16”  
VP507  
6x 8 ½”  
7Round  
8Round  
VP502  
L114A  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Rev. 04/08  

Toshiba Laptop U900 User Manual
TRENDnet Network Card TE100 P11 User Manual
Turtle Beach Computer Hardware DSS User Manual
Ultimate Ears Headphones 200vi User Manual
Vermont Casting Ventilation Hood DVRS3 User Manual
ViewSonic Computer Monitor VA1931WM User Manual
Viking Cooktop F21208 User Manual
Vinotemp Refrigerator VT 45 User Manual
Vizio Flat Panel Television XMA500 User Manual
VTech Cordless Telephone CS6409 User Manual