Vector Power Supply VEC025MB User Manual

VEC025MB  
VEC025MY  
START-IT  
JUMPSTART SYSTEM & POWER SUPPLY  
PORTABLE, CORDLESS, RECHARGEABLE 12 volt DC POWER SUPPLY  
PORTABLE,  
SAFE AND  
CONVENIENT  
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS  
PRODUCT. BEFORE USE, READ AND UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S  
BATTERY MANUFACTURER GUIDELINES. FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE.  
OWNER’S MANUAL  
4140 S.W. 28th Way  
Ft. Lauderdale, FL 33312  
4140 S.W. 28th Way, Ft. Lauderdale, FL 33312  
Tel: (954) 584-4446 • Fax: (954) 584-5556  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
WARNINGS  
3 YEAR EXTENDED WARRANTY REGISTRATION FORM  
JUMPSTART PROCEDURES SHOULD ONLY BE PERFORMED IN A SAFE, DRY, WELL  
VENTILATED AREA OR COMPARTMENT. ANY HATCH OR ENGINE COMPARTMENT  
SHOULD BE OPEN AND OR WELL VENTILATED TO REDUCE RUSK OF FIRE, ELECTRIC  
SHOCK, EXPLOSION OR INJURY.  
Certain Vector Manufacturing, Ltd. products are eligible to be covered to the original purchaser only, for three  
(3) years from the date of purchase, to be free of defects in materials or workmanship. Vector Manufacturing,  
Ltd. disclaims any liability for consequential damages. In no event will Vector Manufacturing, Ltd. be responsible  
for any amount of damages beyond the amount paid for the product at retail. In the event of a defective item,  
please ship the item to us, prepaid, with an explanation of the problem, your name, address and daytime tele-  
phone number. Vector Manufacturing, Ltd. will, at its option, replace or repair the defective part.  
WHEN WORKING WITH LEAD ACID BATTERIES, ALWAYS MAKE SURE IMMEDIATE ASSISTANCE IS  
AVAILABLE IN CASE OF ACCIDENT OR EMERGENCY.  
ALWAYS USE PROTECTIVE EYEWEAR WHEN USING THIS PRODUCT: CONTACT WITH BATTERY ACID MAY  
CAUSE BLINDNESS AND/OR SEVERE BURNS. BE AWARE OF FIRST AID PROCEDURES IN CASE OF  
ACCIDENTAL CONTACT WITH BATTERY ACID.  
THERE IS A RISK OF EXPLOSIVE GASES BEING RELEASED WHEN LEAD ACID BATTERIES ARE BEING  
CHARGED OR DISCHARGED. FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE PROPERTY DAMAGE,  
EXPLOSIVE HAZARD AND/OR PERSONAL INJURY.  
WHEN CHARGING UNIT FROM A 110 VOLT AC ELECTRICAL OUTLET IN ANY WET OR DAMP AREA,  
MAKE SURE THAT THE OUTLET USED IS PROTECTED BY A GROUND FAULT INTERRUPT (GFI) SWITCH.  
WHEN CHARGING THE UNIT NEAR WATER, DO NOT ALLOW THE ELECTRICAL CORDS AND OUTLETS TO  
GET WET OR COME NEAR WATER—ELECTRICAL SHOCK COULD RESULT!  
ALWAYS STORE BATTERY CLAMPS IN BUILT-IN HOLSTERS WHEN NOT IN USE. NEVER TOUCH BATTERY  
CLAMPS TOGETHER—THIS CAN CAUSE DANGEROUS SPARKS, POWER ARCING AND/OR EXPLOSION.  
WHEN USING THIS UNIT IN PROXIMITY TO THE VESSEL'S OR VEHICLE’S BATTERY AND ENGINE, STAND THE  
UNIT ON AC FLAT, STABLE SURFACE, AND BE SURE TO KEEP ALL CLAMPS, CORDS, CLOTHING AND BODY  
PARTS AWAY FROM MOVING VEHICLE COMPONENTS.  
The following situations are not covered under this warranty:  
Cost of shipment to Vector Manufacturing, Ltd.  
Normal wear and tear, including chips, scratches, abrasions, discoloration or fading due to usage or  
exposure to sunlight.  
Damage caused by misuse, abuse, neglect, alterations, repairs by unauthorized persons, or failure to  
follow recommended care and use instructions.  
Bulbs, fuses and batteries.  
Please activate my Extended Warranty for Model VEC025MB or VEC025MY  
Name ________________________________________________________________________________________________  
Street Address _________________________________________________________________________________________  
City________________________________________  
State______________________ Zip code___________________  
Phone________________________  
Fax___________________________ E-mail ______________________________  
DO NOT WEAR VINYL CLOTHING WHEN JUMPSTARTING A VESSEL OR VEHICLE—FRICTION CAN CAUSE  
DANGEROUS STATIC ELECTRICITY SPARKS. REMOVE ALL JEWELRY OR METAL OBJECTS THAT COULD  
CAUSE SHORT CIRCUITS OR REACT WITH BATTERY ACID.  
Item Purchased _________________________________  
Store Where Purchased __________________________  
Date of Purchase _____________________________________  
UPC Number from package (12 digits)___________________  
ALWAYS DISCONNECT THE NEGATIVE (BLACK) JUMPER CABLE FIRST: FOLLOWED BY THE POSITIVE (RED)  
JUMPER CABLE.  
Form of Payment (VEC025MB or VEC025MY US$25)  
Check  
Money Order  
NEVER ALLOW RED AND BLACK CLAMPS TO TOUCH EACH OTHER OR ANOTHER COMMON METAL  
CONDUCTORTHIS COULD CAUSE DAMAGE TO THE UNIT AND/OR CREATE SPARKING/EXPLOSION  
HAZARD. ALWAYS STORE BATTERY CLAMPS IN BUILT-IN HOLSTERS WHEN NOT IN USE.  
DO NOT EXPOSE BATTERY TO FIRE OR INTENSE HEAT AS IT MAY EXPLODE. BEFORE DISPOSING OF THE  
BATTERY, PROTECT EXPOSED TERMINALS WITH HEAVY-DUTY ELECTRICAL TAPE TO PREVENT SHORTING  
(SHORTING CAN RESULT IN INJURY OR FIRE).  
DO NOT SMOKE OR USE INFLAMMABLE ITEMS (MATCHES, CIGARETTE LIGHTERS, ETC.) WHILE WORKING  
ON A VEHICLES BATTERY SYSTEM.  
KEEP UNIT OUT OF REACH OF CHILDREN (WHETHER STORED OR IN USE).  
All Vector Manufacturing, Ltd. products must be registered within (10) days of purchase to activate this warranty.  
Mail the completed registration form, along with a copy of the original sales receipt, and a check or money order  
for US$25 made payable to Vector Manufacturing, Ltd., to:  
ATTN: CUSTOMER SERVICE  
VECTOR MANUFACTURING, Ltd.  
4140 S.W. 28th WAY  
FT. LAUDERDALE, FL 33312  
WARRANTY MUST BE PURCHASED WITHIN 90 DAYS OF PRODUCT PURCHASE DATE.  
WARRANTY IS NON-TRANSFERABLE AND NON-REFUNDABLE.  
FIRST AID:  
SKIN: IF BATTERY ACID COMES IN CONTACT WITH SKIN, RINSE IMMEDIATELY WITH WATER, THEN WASH  
THOROUGHLY WITH SOAP AND WATER. IF REDNESS, PAIN, OR IRRITATION OCCURS, SEEK  
IMMEDIATE MEDICAL ATTENTION.  
EYES: IF BATTERY ACID COMES IN CONTACT WITH EYES, FLUSH EYES IMMEDIATELYFOR MINIMUM OF  
15 MINUTESSEEK IMMEDIATE MEDICAL ATTENTION.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
CAUTIONS  
120 DAY LIMITED WARRANTY REGISTRATION FORM  
CAUTION STATEMENTS ADVISE AGAINST CERTAIN CONDITIONS AND  
PRACTICES THAT MAY RESULT IN DAMAGE TO VEHICLES, APPLIANCES  
AND/OR THE START-IT™ JUMPSTART SYSTEM.  
All Vector Manufacturing, Ltd. products are warranted to the original purchaser only, for 120 days from the date of  
purchase, to be free of defects in materials and workmanship. In no event will Vector Manufacturing, Ltd. be responsible for  
any amount of damages beyond the retail purchase price of the product. All Vector Manufacturing, Ltd. products must be  
registered within (10) days of purchase. To activate this warranty, mail the completed registration form along with a copy  
of the original sales receipt to the address shown below.  
IMPORTANT: ALTHOUGH THIS UNIT IS DELIVERED IN A PARTIALLY-CHARGED STATE - YOU MUST FULLY  
CHARGE IT WITH THE SUPPLIED 110 VOLT AC CHARGER FOR A FULL 24 HOURS, BEFORE USING IT FOR  
THE FIRST TIME.  
TERMS OF REPAIR OR REPLACEMENT: In the event of a defective unit, return the unit to us within 30 days of the date of  
purchase, and we will replace it, free of charge. If returned after 30 days but within 120 days of the purchase date we will  
repair the unit or, at our option, replace it free of charge. If we repair the unit, we may use new or reconditioned  
replacement parts, at our option. If we elect to replace the unit, we may replace it with a new or reconditioned one of  
the same or comparable design. The repair or replacement unit will then be warranted under the terms of our standard 120  
day warranty. The customer is responsible for shipping charges on all returned items. During the warranty period, Vector  
Manufacturing, Ltd. will be responsible for the repair or replacement cost plus the return shipping charges.  
IMPORTANT: DO NOT OVERCHARGE UNIT, THIS WILL REDUCE BATTERY LIFE.  
USE ONLY THE SUPPLIED CORDS FOR RECHARGING/OPERATING THIS UNIT. DO NOT RECHARGE FOR  
MORE THAN 3-4 HOURS MAXIMUM USING 12 VOLT DC METHOD. RECHARGE UNIT AFTER EACH USE.  
ALL ON/OFF SWITCHES SHOULD BE IN THE OFF POSITION WHEN THE UNIT IS CHARGING OR NOT IN  
USE. MAKE SURE ALL SWITCHES ARE IN THE OFF POSITION BEFORE CONNECTION TO A POWER  
SOURCE OR LOAD.  
NEVER INSERT ANYTHING OTHER THAN THE SUPPLIED POWER/RECHARGING CORDS OR  
RECOMMENDED APPLIANCE POWER/RECHARGING CORDS INTO THE 12 VOLT DC CHARGING/POWER  
SOCKET ON THIS UNIT. DO NOT USE ANY ACCESSORY THAT IS NOT RECOMMENDED OR PROVIDED BY  
THE MANUFACTURER.  
LIMITATIONS: Implied warranties, including those of fitness for a particular purpose and merchantability (an unwritten  
warranty that the product is fit for ordinary use), are limited to 120 days from the purchase date. Vector Manufacturing,  
Ltd. will not reimburse for loss of time, inconvenience, loss of use of a product, or property damage caused by a product or  
its failure to work, or any other incidental or inconsequential damages, including personal injury.  
DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE THAN 20 AMPS.  
THIS SYSTEM IS DESIGNED TO BE USED ONLY ON VESSELS OR VEHICLES WITH 12 VOLT DC BATTERY  
SYSTEMS. DO  
EXCLUSION: This warranty does not cover bulbs, fuses and batteries, defects resulting from normal wear and tear  
(including chips, scratches, abrasions, discoloration or fading due to usage or exposure to sunlight), accidents, damage  
during shipping to our service facility, alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow  
instructions for care and maintenance, fire, flood, and Acts of God. If your problem is not covered by this warranty, call  
our customer service facility at (954) 584-4446 for general repair information and charges. This limited warranty is the  
only one that applies to this product, and sets forth all the responsibilities of Vector Manufacturing, Ltd, regarding this product.  
There are no warranties which extend beyond those described herein.  
NOT CONNECT TO A 6 VOLT OR 24 VOLT BATTERY SYSTEM.  
THIS SYSTEM IS NOT DESIGNED TO BE USED AS A REPLACEMENT FOR A VEHICULAR BATTERY. DO NOT  
ATTEMPT TO JUMPSTART A VESSEL OR VEHICLE THAT DOES NOT HAVE A BATTERY INSTALLED.  
EXCESSIVE ENGINE CRANKING CAN DAMAGE A VESSEL'S OR VEHICLES STARTER MOTOR. IF THE  
STATE LAW RIGHTS: Some states do not allow limitations on how long an implied warranty lasts or the exclusion or  
limitation of incidental or consequential damages, so the exclusions or limitations stated herein may not apply. This  
warranty gives the purchaser specific legal rights; other rights, varying from state to state, may apply.  
ENGINE  
FAILS TO START AFTER THE RECOMMENDED NUMBER OF ATTEMPTS. DISCONTINUE JUMPSTART PROCE-  
DURE  
AND LOOK FOR OTHER PROBLEMS THAT MAY NEED TO BE CORRECTED.  
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Within 30 days of the purchase date, return the unit, along with  
the dated sales receipt, to the place of purchase for immediate replacement. After 30 days, but within the 120 day  
warranty period, you may return the product to the address shown below. We suggest that you retain the original  
packaging in case you need to ship the unit. When returning a product, include your name, address, phone number, dated  
sales receipt and a description of the reason for return. After repairing or replacing the unit, we will return it to you  
within four weeks.  
ALTHOUGH THIS UNIT CONTAINS A NON-SPILLABLE BATTERY, IT IS RECOMMENDED THAT UNIT BE KEPT  
UPRIGHT DURING STORAGE, USE AND RECHARGING. TO AVOID POSSIBLE DAMAGE THAT MAY SHORTEN  
THE UNITS WORKING LIFE, PROTECT IT FROM DIRECT SUNLIGHT, DIRECT HEAT AND/OR MOISTURE.  
CHECK UNIT PERIODICALLY FOR WEAR AND TEAR. REPLACE WORN OR DEFECTIVE PARTS IMMEDIATELY.  
CONTACT VECTOR® CUSTOMER SERVICE DEPARTMENT AT (954) 584-4446.  
VECTOR MANUFACTURING, Ltd.  
4140 S.W. 28th WAY  
FT. LAUDERDALE, FL 33312  
DO NOT ATTEMPT TO JUMPSTART A FROZEN BATTERY.  
NEVER SUBMERGE THIS UNIT IN WATER.  
Please activate my Limited Warranty for Model VEC025MB or VEC025MY  
I have enclosed a copy of the original sales receipt.  
BATTERY REPLACEMENT:  
Name ________________________________________________________________________________________________  
Street Address _________________________________________________________________________________________  
IT IS RECOMMENDED TO RETURN UNIT TO VECTOR® CUSTOMER SERVICE FOR BATTERY REPLACEMENT:  
CONTACT (954) 584-4446  
City________________________________________  
State______________________ Zip code___________________  
Phone________________________  
Fax___________________________ E-mail ______________________________  
BATTERY DISPOSAL:  
Item Purchased _________________________________  
Store Where Purchased __________________________  
Date of Purchase _____________________________________  
UPC Number from package (12 digits)___________________  
THIS UNIT CONTAINS A MAINTENANCE-FREE, SEALED, NON-SPILLABLE, LEAD ACID  
BATTERY WHICH MUST BE DISPOSED OF PROPERLY. SOME STATES REQUIRE RECYCLING.  
DISPOSAL QUESTIONS? IN USA, CALL 1-877-288-7722.  
All Vector Manufacturing, Ltd. products must be registered within (10) days of purchase to activate this warranty. Mail the  
completed registration form, along with a copy of the original sales receipt, to:  
ATTN: CUSTOMER SERVICE  
VECTOR MANUFACTURING, LTD.  
4140 S.W. 28th WAY  
FT. LAUDERDALE, FL 33312  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
3
3
11  
1
2
FIGURE 1  
6. BATTERY REPLACEMENT  
IT IS RECOMMENDED THAT THE UNIT BE RETURNED TO VECTOR® CUSTOMER SERVICE FOR BATTERY  
REPLACEMENT: CONTACT (954) 584-4446.  
10  
9
1. 12 Volt DC Charger/Output Socket,  
with Overload Protection  
5
6.1 Battery Disposal  
Contains a maintenance-free, sealed, non-spillable, lead acid battery, which must be disposed of properly. Some  
2. Safety ON/OFF Power Switch (No Key Required)  
3. Charge Status Button  
states require recycling contact your local authority for information.  
6
4
4. Heavy-Duty #4AWG Welding Quality Jumper Cables  
5. Heavy-Duty, Nickel Plated Copper Clamps  
THIS UNIT CONTAINS A MAINTENANCE-FREE, SEALED, NON-SPILLABLE, LEAD ACID  
BATTERY WHICH MUST BE DISPOSED OF PROPERLY. SOME STATES REQUIRE RECYCLING.  
DISPOSAL QUESTIONS? IN USA, CALL 1-877-288-7722  
6. Exclusive, Quick-Release, Spring-Loaded Clamp  
Holsters  
7
7. 110 Volt AC/DC Charging Adapter Cord  
8. 12 volt DC/DC Charging Adapter Cord  
9. Built-in Emergency Worklight  
10. Light ON/OFF Switch  
WARNINGS:  
DO NOT DISPOSE OF THE BATTERY IN FIRE AS THIS MAY RESULT IN AN EXPLOSION.  
BEFORE DISPOSING OF THE BATTERY, PROTECT EXPOSED TERMINALS WITH HEAVY-DUTY  
ELECTRICAL TAPE TO PREVENT SHORTING (SHORTING CAN RESULT IN INJURY OR FIRE).  
DO NOT EXPOSE BATTERY TO FIRE OR INTENSE HEAT AS IT MAY EXPLODE.  
8
7. SPECIFICATIONS  
FEATURES  
Models......................................................................................VEC025MB, VEC025MY  
Voltage..............................................................................................................12 VDC  
Boost Power ................................................................400 Instantaneous Cranking Amps  
Peak Ampere Power........................................................................................900 Amps  
Heavy duty, professional quality.  
Easy-to-use: emergency jumpstarter for boats, cars, light trucks, jet skis, personal water craft, snowmobiles, farm  
equipment, airplanes, small SUVs and RVs (any 12 volt battery system).  
Battery Type.......................................Sealed, lead- acid, rechargeable, maintenance-free,  
...............................................................................................12 Volt DC, 19 Amp-hour  
Provides INSTANT 12 VOLT DC POWER whenever and wherever its needed.  
Ideal for vessel, vehicle, home, tailgate parties, beach, picnic, campsite, wilderness, utility power outages,  
Bulb .........................................................................................12 Volt 0.4 Amp Krypton  
Booster Cables .............................................................................#4AWG welding cable  
......................................................................with 400 Amp nickel plated copper clamps  
Accessory Socket Self-Resetting Breaker..............................................................20 Amps  
Charging Cord...............................................................................................12 Volt DC  
Adapter/Charger.........................................................................................110 Volt AC  
..........................................................................................(600mA, 12 Volt DC Output)  
emergency repair, etc.  
Sturdy and compact unit provides up to 50 hours of completely portable 12 volt DC power.  
Built-in cigarette lighter-type socket for use with 12 volt DC accessories or DC/AC Inverter for use with 110 volt  
AC accessories.  
Portable, safe & convenient goes where extension cords cant reach and utility power is not available.  
ON/OFF safety power switch (no key required, no key to get lost!).  
HEIGHT ........................................................................................11-3/4(29.845CM)  
DEPTH ............................................................................................6-1/4(15.875CM)  
WIDTH ..........................................................................................11-5/8(29.528CM)  
WEIGHT .............................................................................................18LBS. (8.164KG)  
Cordless/rechargeable includes charging cords for standard 110 volt AC wall socket and vehicles  
12 volt DC accessory outlet.  
Powerful 400 instantaneous cranking amps; 900 peak amps.  
Solid-state, automatic operation and built-in circuit protection.  
Safe to use, transport and store.  
Includes non-spillable, maintenance-free, heavy-duty, 19 amp hour sealed battery.  
Requires no maintenance (other than recharging) for optimum operation.  
Molded high-impact case is tough and durable.  
8. REPLACEMENT PARTS  
For replacement parts (bulbs, batteries, fuses, etc.), contact Vector® Customer Service: (954) 584-4446.  
Built-in, heavy-duty, corrosion resistant industrial grade nickel plated copper clamps con-  
tacts and #4AWG jumper cables with exclusive spring-loaded, quick-release storage hol-  
sters.  
110 volt AC charger is Underwriter Laboratories safety tested and listed.  
Easy-to-read LED battery charging/status indicators.  
Built-in halogen work/emergency light with ultra-bright krypton bulb for roadside repairs and use in remote loca-  
tions without utility power.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
9
IMPORTANT INFORMATION:  
CAUTION: READ INSTRUCTION MANUAL AND PRODUCT LABELING CAREFULLY, FOR COMPLETE  
INSTRUCTIONS, BEFORE USING THIS PRODUCT. FOLLOW RECOMMENDED WARNINGS, CAUTIONS,  
SAFETY PROCEDURES AND MANUFACTURER GUIDELINES FOR YOUR VEHICLES BATTERY.  
4. OPERATION AS A PORTABLE POWER SUPPLY  
4.1 Operation as a 12 Volt DC Power Supply  
NOTE: Make sure that the unit s safety ON/OFF switch is ALWAYS in the OFF position when using the  
12 volt DC accessory outlet.  
IMPORTANT: ALTHOUGH THIS UNIT IS DELIVERED IN A PARTIALLY-CHARGED STATEYOU  
MUST FULLY CHARGE IT WITH THE SUPPLIED 110 VOLT AC CHARGER FOR A FULL 24 HOURS,  
BEFORE USING IT FOR THE FIRST TIME.  
1.Lift up the cover of the unit s 12 volt DC cigarette lighter-type receptacle (See Figure 1, #1).  
2.Insert the 12 volt DC plug from the appliance into the receptacle on the unit.  
3.Switch on the appliance and operate as usual.  
IMPORTANT: DO NOT OVERCHARGE UNIT, THIS WILL REDUCE BATTERY LIFE. CHARGE UNTIL GREEN  
CHARGEDINDICATOR IS LIT WHEN CHARGE STATUS BUTTON IS PRESSED. AFTER GREEN CHARGED”  
INDICATOR LIGHTS COMES ON WHEN CHARGE STATUS BUTTON IS PRESSED, UNIT CAN BE TOP-OFF  
CHARGED FOR AN ADDITIONAL HOUR USING THE DC METHOD OR 2-4 HOURS USING THE AC METHOD.  
CAUTION: DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE THAN 20 AMPS.  
FULLY RECHARGE UNIT AFTER EACH USE OR WHEN CHARGE STATUS INDICATOR SHOWS LOWER THAN  
FULLAND EVERY 2 MONTHS WHEN NOT IN USE.  
4.2 Estimated 12 Volt DC Usage Times  
Table II shows the estimated 12 volt DC operation times when using a fully-charged system.  
ALWAYS RECHARGE IN A DRY, WELL-VENTILATED AREA, AWAY FROM WATER AND FUMES.  
WHEN CHARGING IN ANY WET OR DAMP AREA FROM A 110 VOLT ELECTRICAL  
OUTLET, MAKE SURE THAT THE OUTLET USED IS PROTECTED BY A GROUND FAULT  
INTERRUPT (GFI) SWITCH.  
Table II START-ITas a 12 volt DC Power Supply  
ESTIMATED POWER  
CONSUMPTION (IN WATTS)  
ESTIMATED USAGE  
TIME (IN HOURS)  
WHEN CHARGING THE UNIT NEAR WATER (POOL, DOCKSIDE, BEACH, ETC.) DO NOT ALLOW THE  
ELECTRICAL CORDS AND OUTLETS TO GET WET OR COME NEAR WATER ELECTRICAL  
SHOCK COULD RESULT!  
APPLIANCE TYPE  
CELL PHONE  
FLUORESCENT LIGHT  
RADIO, FAN, DEPTH FINDER  
CAMCORDER, VCR, SPOTLIGHT  
POWER TOOLS, BILGE PUMP  
ELECTRIC COOLER  
3
4
9
15  
24  
48  
80  
35  
30  
21  
12  
7
USE ONLY THE SUPPLIED CORDS FOR RECHARGING/OPERATING THIS UNIT.  
IT IS RECOMMENDED THAT UNIT BE KEPT UPRIGHT DURING USE AND WHEN RECHARGING.  
WHEN NOT IN USE, STORE UNIT WITH ON/OFF SWITCH TURNED OFF.  
3
1.5  
AIR COMPRESSOR, CAR VACUUM  
SAFETY WARNINGS:  
THERE IS A RISK OF EXPLOSIVE GASES BEING RELEASED WHEN BATTERIES ARE IMPROPERLY CHARGED OR  
DISCHARGED. FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE PROPERTY DAMAGE, EXPLOSIVE HAZARD  
AND/OR PERSONAL INJURY.  
NOTE:ALL TIMES ARE APPROXIMATE, AND BASED UPON FULLY CHARGED UNIT.  
ALWAYS USE PROTECTIVE EYEWEAR WHEN USING THIS PRODUCT. CONTACT WITH BATTERY  
4.3 Operation as a 110 Volt AC Power Supply  
Use with VEC040 (50 Watt), VEC023 (175 Watt), or VEC024 (400 Watt) MAXX Power Inverters  
ACID MAY CAUSE SEVERE BURNS.  
KEEP OUT OF REACH OF CHILDREN.  
®
,
sold separately. For estimated usage times, see chart provided with inverter  
.
ALWAYS STORE BATTERY CLAMPS IN BUILT-IN HOLSTERS WHEN NOT IN USE. NEVER TOUCH BATTERY  
CLAMPS TOGETHER THIS CAN CAUSE DANGEROUS SPARKS, POWER ARCING AND/OR EXPLOSION.  
1.Lift up the cover of the unit s 12 volt DC cigarette lighter-type receptacle (See Figure 1, #1).  
2.Insert the 12 volt DC plug from the power inverter into the receptacle on the unit.  
3. Plug the appliance into the 110 Volt AC receptacle on the inverter.  
4. Switch on the appliance and operate as usual.  
FIRST AID:  
SKIN: IF BATTERY ACID COMES IN CONTACT WITH SKIN, RINSE IMMEDIATELY WITH WATER, THEN WASH  
THOROUGHLY WITH SOAP AND WATER. IF REDNESS, PAIN OR IRRITATION OCCURS, SEEK  
IMMEDIATE MEDICAL ATTENTION.  
CAUTION: DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE THAN  
200 WATTS OR EXCEED MAXIMUM WATTAGE OF INVERTER.  
EYES: IF BATTERY ACID COMES IN CONTACT WITH EYES, FLUSH EYES IMMEDIATELY FOR MINIMUM  
OF 15 MINUTES SEEK IMMEDIATE MEDICAL ATTENTION.  
5. EMERGENCY/WORK LIGHT  
Bulb Replacement  
1.Replacement bulbs are available from Vector® Customer Service Department; call (954) 584-4446.  
2.Remove the lens cover.  
3.Remove the burned-out bulb.  
4.Replace with a new bulb (12 volt 0.4 amp Krypton bulb) available from  
Vector® Customer Service Department; call (954) 584-4446.  
5.Snap the lens cover back into place.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
5
3.2 12 Volt DC Charging  
1. INTRODUCTION  
The START-ITsystem also comes with a DC/DC charging cord, for recharging the unit from the 12 volt DC  
cigarette lighter socket in a vehicle or boat. Note: This recharging method will NOT recharge the unit as  
effectively as recharging from a 110 volt AC outlet. The 12 volt DC recharging procedure is recommended only  
when it is necessary, as continued use of the 12 volt DC recharging procedure may shorten the battery systems life.  
®
Congratulations on selecting the Vector START-ITJUMPSTART SYSTEM & 12 VOLT DC POWER SUPPLY.  
Please read this guide carefully before use to ensure optimum performance and avoid damage to the unit or items  
with which you are using it. This manual describes models VEC025MB (Blue) and VEC025MY (Yellow).  
®
The Vector START-ITJUMPSTART SYSTEM & 12 volt DC POWER SUPPLY is a compact, durable and portable  
WARNING: DO NOT RECHARGE FOR MORE THAN 6 HOURS MAXIMUM USING 12 VOLT DC METHOD.  
1.NOTE: If unit is fully discharged, it is recommended that the vehicle being used for recharging be left running  
while the unit is being charged via the 12 volt DC method.  
2.Insert one end of the DC/DC charging cord into the 12 volt DC cigarette lighter receptacle on the vehicle  
or boat.  
3.Insert the plug at the other end of this power cord into the 12 volt DC receptacle on the front panel  
of the unit.  
4.Charge the unit until the green FULL LED indicator lights when Charge Status Indicator Button is pressed.  
DO NOT EXCEED 6 HOURS MAXIMUM.  
jumpstart system for vehicles and boats that have a standard 12 volt battery system. This self-contained, recharge-  
able system will start most boats and vehicles without the need for a host or 110 volt AC power supply.  
It can also be used as a safe, portable source of 12 volt DC electric power in remote locations and/or emergency  
situations. It is ideal for use with Vector 12 volt DC cordless, portable, rechargeable products and MAXX DC/AC  
Power Inverters. Use the START-ITto:  
®
®
-Jumpstart:  
Any vehicle with a standard 12 volt DC battery system; boat, truck, car, airplane, RV, personal watercraft,  
snowmobile, tractor, etc.  
-Operate: 12 volt DC  
Fans, inflators, fluorescent work lights, cellular phones*, air compressors, inflators, spotlights, TVs, portable  
radios, cassette, CD players and more. *Can quick-charge a cellular phone by using the phones 12 volt DC  
adapter cord.  
5.When charging is completed, remove the power cord and store in a safe place.  
3.3 110 Volt AC Charging Using VEC070 Automatic Battery Charger (purchased separately)  
-Operate: Certain 110 volt AC Accessories (requires DC to AC power inverter, sold separately)  
1. Install the chargers DC wire with battery clips.  
2. The jumpstarter has a high-current switch for turing the heavy-duty clamps ON and OFF, make sure  
the Safety switch is turned OFF.  
The START-ITSYSTEM has an easy-to-read, series of LED (Light Emitting Diode) charge indicators that show when the  
unit is fully charged or the level of charge in the battery. Charge level can be viewed when the charge status  
button is pressed. A 12 volt DC cigarette lighter-type socket is provided for use with appliances that can operate from  
a vehicle cigarette lighter. This allows maximum portability and utility when the START-ITis used in remote locations.  
3. Connect the POSITIVE (RED) DC Battery Clip to the RED POSITIVE jumpstarter clamp.  
4. Connect the NEGATIVE (BLACK) DC Battery Clip to the BLACK NEGATIVE jumpstarter clamp.  
5. Connect the charger to an AC outlet or extension cord rated at 18 AWG or larger.  
6. Turn ON the Safety switch and observe the RED LED on the charger for proper operation.  
For maximum convenience, the START-ITcan be recharged from any standard 110 volt AC or 12 volt DC power  
source using the built-in 12 volt socket and the appropriate charging/adapter cord. When depressed, the PUSH FOR  
STATUS switch will show the battery s power level status (from Low to Full). The green LED FULL indicator illuminates  
when the unit is fully recharged. An ON/OFF switch operates the built-in work/emergency light.  
7. Charge the START-ITuntil the green Charged LED lights when Charge Status Button is pressed.  
Then continue charging for another hour.  
8. When charging is complete, Turn OFF the Safety switch.  
9. Disconnect the charger from the AC outlet or extension cord.  
10. Disconnect the chargers battery clips from the jumpstarters clamps.  
11. Store the charger as described in its Owners Manual.  
12. Place the jumpstarter back into service.  
WARNING:  
Lead-acid batteries generate hydrogen gas during normal operation. More gas is generated when the battery is  
charging. Hydrogen gas is: EXPLOSIVE POISONOUS TO BREATHE HIGHLY FLAMMABLE  
To avoid an explosion and/or the possibility of being splashed with battery acid:  
NEVER allow the red and black clamps to touch each other or a common metal object.  
ONLY attempt to jumpstart a vehicle or boat in a WELL ventilated area.  
ALWAYS CONNECT THE RED (+) CLAMP TO THE POSITIVE (+) BATTERY TERMINAL FIRST.  
DO NOT CONNECT THE BLACK (-) CLAMP TO THE NEGATIVE (-) BATTERY TERMINAL.  
CONNECT THE BLACK (-) CLAMP TO A NON-MOVING METAL PART ON THE ENGINE.  
3.4 Estimated Battery Life  
Table I shows the relationship of the frequency of use between recharging and the expected number of  
discharge/recharge cycles  
Table I Estimated Battery Life  
CAUTIONS:  
I. To avoid possible damage that may shorten the units working life, protect this unit from direct sunlight,  
direct heat and/or moisture.  
AVERAGE NUMBER OF USES  
POTENTIAL TOTAL NUMBER  
2. This system is designed to be used ONLY on boats or vehicles with 12 volt DC battery systems.  
3. This system is NOT designed to be used as a replacement for a vehicular battery.  
(JUMPSTART OR DISCHARGES) . . . . . . . .OF JUMPSTART OR DISCHARGE CYCLES  
BETWEEN RECHARGES . . . . . . . . . . . . . .(LIFETIME OF UNIT BATTERY)  
1 . . . . . . . . . . . . . . . . . . . . . . . . . 1000+  
5
. . . . . . . . . . . . . . . . . . . . . . . . . 700+  
RECOMMENDATIONS FOR OPTIMUM PERFORMANCE OF THE START-ITJUMPSTART SYSTEM:  
WARNING: NEVER insert anything other than the supplied power/recharging cords or recommended  
appliance power/recharging cords into the charging/power sockets on this unit.  
IMPORTANT: The safety ON/OFF switch should be in the OFF position when the unit is charg-  
ing, or not in use.  
10 . . . . . . . . . . . . . . . . . . . . . . . . . 500+  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
7
NEVER ALLOW RED AND BLACK CLAMPS TO TOUCH EACH OTHER OR ANOTHER  
COMMON METAL CONDUCTOR THIS COULD CAUSE DAMAGE TO THE UNIT AND/OR  
CREATE SPARKING/EXPLOSION HAZARD.  
There is a risk of explosive gases being released when batteries are improperly charged  
or discharged. Failure to follow instructions may cause property damage, explosive  
hazard and/or personal injury.  
ALWAYS USE PROTECTIVE EYEWEAR WHEN USING THIS PRODUCT: CONTACT WITH BATTERY  
ACID MAY CAUSE BLINDNESS AND/OR SEVERE BURNS.  
Keep out of reach of children.  
2. USING THE START-ITAS A JUMPSTART SYSTEM  
CAUTIONS:  
Before using this system to jump start any boat or vehicle engine, read and understand all instructions, safety tips,  
warnings and cautions and first aid information provided in this manual and on the product labeling.  
Additional important information may also be provided by the vessel's or vehicle s battery system manufacturer.  
Excessive engine cranking can damage the vessel's or vehicle s starter motor. If the engine fails to start after the  
recommended number of attempts, discontinue jumpstart procedure and look for other problems that may  
need to be corrected.  
ALWAYS store battery clamps in built-in holsters when not in use. Never touch battery  
clamps togetherthis can cause dangerous sparks, power arcing and/or explosion.  
FIRST AID:  
2.1 EASY, STEP-BY-STEP JUMPSTARTING INSTRUCTIONS  
Skin: If battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly with soap  
and water. If redness, pain, or irritation occurs, SEEK IMMEDIATE MEDICAL ATTENTION.  
Eyes: If battery acid comes in contact with eyes, flush eyes immediatelyfor minimum of 15 minutes SEEK  
IMMEDIATE MEDICAL ATTENTION.  
1. Turn OFF vessel's or vehicles ignition and all accessories (radio, a/c, lights, cell phone, etc.). Place  
vehicle in parkand set the emergency brake.  
2. Make sure jumpstart system safety switch is turned OFF.  
3. Follow procedure for negative or positive grounded system,  
as follows:  
NEGATIVE GROUNDED SYSTEM  
3. CHARGING/RECHARGING  
Figure 2  
(NEGATIVE BATTERY TERMINAL IS CONNECTED TO MAIN  
Fixed Clamp  
ENGINE BLOCKMOST COMMON METHOD:  
For maximum battery life, we recommend that the START-ITsystem be kept fully charged at all times. If the  
battery is allowed to remain in a discharged state, battery life may be shortened. Note: Recharging battery after  
each use will prolong battery life; frequent discharges between recharges will reduce battery life.  
Cover  
TO REMOVE BOOSTER CLAMPS FROM PROTECTIVE HOLSTER  
(FIG. 2): SIMPLY PULL DOWN ON CLAMP, (SHOULDER REST  
IS SPRING LOADED)ROTATE TOP OF CLAMP OUTWARD  
WHILE YOU PULL DOWNWHEN CLEAR OF CLAMP  
COVER REMOVE CLAMP.  
3.1 110 Volt AC Charging  
IMPORTANT:  
MAKE SURE SAFETY ON/OFF SWITCH IS IN OFF POSITION DURING RECHARGING.  
Charge unit for full 24 hours, prior to first use.  
Recharge unit fully after each use.  
Clamp Holster  
Shoulder  
TO REPLACE BOOSTER CLAMP INTO PROTECTIVE HOLSTER—  
RETURN CLAMP TO SHOULDER REST, ROTATE OUT AND  
PUSH DOWN THEN SLIDE CLAMP UP INTO PROTECTIVE  
COVER.  
Recharge unit every two months, when it has not been used.  
CONNECT POSITIVE (+) RED CLAMP TO VEHICLE BATTERY S  
POSITIVE TERMINAL.  
CONNECT NEGATIVE (-) BLACK CLAMP TO CHASSIS OR A  
SOLID, NON-MOVING, METAL MAIN ENGINE PART. NEVER  
SLIDE DOWN AND ROTATE CLAMP OUTWARD  
FROM BACK OF UNIT TO REMOVE  
1.Simply plug the 110 volt AC plug of the AC/DC adapter/charger cord into any standard  
110 volt AC wall outlet.  
2.Plug the 12 volt DC cigarette type plug into the 12 volt DC receptacle on the unit.  
3.Charge this device for until the FULL LED indicator lights when Charge Status Button is pressed.  
4.NOTE: The unit can be overcharged (which will shorten the life of the battery DO NOT charge with  
AC charging procedure for more than 24 hours maximum.  
CLAMP DIRECTLY TO NEGATIVE BATTERY TERMINAL OR MOVING PART. OF ENGINE.  
4. Turn jumpstart systems safety switch to ON position.  
5. Start vehicle (do not turn key for longer than 5-6 seconds).  
6. After vehicle starts, turn jumpstart system s power switch to OFF position. Remove  
clamps (disconnect the negative (Black) jumper cable first; followed by the positive  
(Red) jumper cable) and replace them in the built-in storage holsters.or moving part.  
5.When charging is completed, remove the power cord and store in a safe place.  
Figure 3  
12 Volt DC  
Charging Cord  
110 Volt AC  
Adapter/Charger  
CAUTIONS:  
If vessel or vehicle fails to start, leave vessel or vehicle ignition key turned OFF, disconnect the negative (-) clamp  
first, then the positive (+) clamp and discontinue jumpstarting procedure.  
Recharge jumpstart system after each use.  
WARNINGS:  
ALWAYS disconnect the negative (Black) jumper cable first; followed by the positive (Red)  
jumper cable.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Telenetics Network Card Modular Nest User Manual
Telex Microphone SB65ELE User Manual
Toshiba Automobile Parts LF400 User Manual
Toshiba Cassette Player MMU AP0071MH User Manual
Toshiba Music Mixer MX 104 User Manual
Toshiba Personal Computer M9 ST5511 User Manual
Toshiba Projector TLF XD2000 User Manual
Triarch Fan CF 31120 User Manual
Tripp Lite Network Cables P770 013 User Manual
Vivitar Digital Camera Vivicam 3715 User Manual