Vector Power Supply VEC021 User Manual

VEC021/021AC  
INDUSTRIAL SERIES 900  
JUMPSTART SYSTEM & POWER SUPPLY  
PORTABLE, CORDLESS, RECHARGEABLE 12-VOLT DC* POWER SUPPLY  
COMPLETELY PORTABLE, SAFE & CONVENIENT  
*INCLUDES INSTRUCTIONS FOR 110-VOLT AC POWER OPTION  
(MODEL VEC023 INVERTER: INCLUDED WITH MODEL VEC021AC; NOT INCLUDED WITH MODEL VEC021)  
THIS MANUAL CONTAINS IMPORTANT INFORMATION REGARDING SAFETY, OPERATION, MAINTENANCE AND STORAGE OF THIS  
PRODUCT. BEFORE USE, READ AND UNDERSTAND ALL CAUTIONS, WARNINGS, INSTRUCTIONS AND PRODUCT LABELS, PLUS YOUR VEHICLE’S  
BATTERY MANUFACTURER GUIDELINES. FAILURE TO DO SO COULD RESULT IN POSSIBLE INJURY OR PROPERTY DAMAGE.  
OWNER’S MANUAL  
4140 S.W. 28th WAY  
FT. LAUDERDALE, FL 33312  
Download from Www.Somanuals.com. All Manuals Search And Download.  
i
ii  
WARNINGS  
CAUTIONS  
WARNING STATEMENTS IDENTIFY CONDITIONS OR PRACTICES THAT MAY RESULT IN  
PERSONAL INJURY OR LOSS OF LIFE.  
CAUTION STATEMENTS ADVISE AGAINST CERTAIN CONDITIONS AND PRACTICES  
THAT MAY RESULT IN DAMAGE TO VEHICLES, APPLIANCES, THE INDUSTRIAL SERIES  
900™ JUMPSTART SYSTEM AND/OR THE POWER FORCE™ INVERTER.  
WHEN WORKING WITH LEAD ACID BATTERIES, ALWAYS MAKE SURE IMMEDIATE ASSISTANCE IS  
AVAILABLE IN CASE OF ACCIDENT OR EMERGENCY.  
IMPORTANT: ALTHOUGH THIS UNIT IS DELIVERED IN A PARTIALLY-CHARGED STATE - YOU MUST FULLY  
CHARGE IT WITH THE SUPPLIED 110-VOLT AC CHARGER FOR A FULL 24 HOURS, BEFORE USING IT FOR  
THE FIRST TIME.  
ALWAYS USE PROTECTIVE EYEWEAR WHEN USING THIS PRODUCT: CONTACT WITH BATTERY ACID MAY  
CAUSE BLINDNESS AND/OR SEVERE BURNS, BE AWARE OF FIRST AID PROCEDURES IN CASE OF  
ACCIDENTAL CONTACT WITH BATTERY ACID.  
IMPORTANT: DO NOT OVERCHARGE UNIT, THIS WILL REDUCE BATTERY LIFE.  
THERE IS A RISK OF EXPLOSIVE GASES BEING RELEASED WHEN LEAD ACID BATTERIES ARE BEING  
CHARGED OR DISCHARGED. FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE PROPERTY DAMAGE,  
EXPLOSIVE HAZARD, AND/OR PERSONAL INJURY.  
USE ONLY THE SUPPLIED CORDS FOR RECHARGING/OPERATING THIS UNIT. DO NOT RECHARGE FOR  
MORE THAN 3-4 HOURS MAXIMUM USING 12-VOLT DC METHOD. RECHARGE UNIT AFTER EACH USE.  
ALL ON/OFF SWITCHES SHOULD BE IN THE OFF POSITION WHEN THE UNIT IS CHARGING OR NOT IN  
USE. MAKE SURE ALL SWITCHES ARE IN THE OFF POSITION BEFORE CONNECTION TO A POWER  
SOURCE OR LOAD.  
WHEN CHARGING UNIT FROM A 110-VOLT AC ELECTRICAL OUTLET IN ANY WET OR DAMP AREA, MAKE  
SURE THAT THE OUTLET USED IS PROTECTED BY A GROUND FAULT INTERRUPT (GFI) SWITCH.  
WHEN CHARGING THE UNIT NEAR WATER, DO NOT ALLOW THE ELECTRICAL CORDS AND OUTLETS TO  
GET WET OR COME NEAR WATER—ELECTRICAL SHOCK COULD RESULT!  
NEVER INSERT ANYTHING OTHER THAN THE SUPPLIED POWER/RECHARGING CORDS OR  
RECOMMENDED APPLIANCE POWER/RECHARGING CORDS INTO THE 12-VOLT DC CHARGING/POWER  
SOCKET ON THIS UNIT. DO NOT USE ANY ACCESSORY THAT IS NOT RECOMMENDED OR PROVIDED BY  
THE MANUFACTURER.  
JUMPSTART PROCEDURES SHOULD ONLY BE PERFORMED IN A SAFE, DRY, WELL VENTILATED AREA.  
ALWAYS STORE BATTERY CLAMPS IN BUILT-IN HOLSTERS WHEN NOT IN USE. NEVER TOUCH BATTERY  
CLAMPS TOGETHER—THIS CAN CAUSE DANGEROUS SPARKS, POWER ARCING, AND/OR EXPLOSION.  
WHEN USING THIS UNIT IN PROXIMITY TO THE VEHICLE’S BATTERY AND ENGINE, STAND THE UNIT ON A  
FLAT, STABLE SURFACE, AND BE SURE TO KEEP ALL CLAMPS, CORDS, CLOTHING AND BODY PARTS AWAY  
FROM MOVING VEHICLE COMPONENTS.  
DO NOT WEAR VINYL CLOTHING WHEN JUMPSTARTING A VEHICLE—FRICTION CAN CAUSE DANGEROUS  
STATIC ELECTRICITY SPARKS. REMOVE ALL JEWELRY OR METAL OBJECTS THAT COULD CAUSE SHORT  
CIRCUITS OR REACT WITH BATTERY ACID.  
DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE THAN 10 AMPS.  
THIS SYSTEM IS DESIGNED TO BE USED ONLY ON VEHICLES WITH 12-VOLT DC BATTERY SYSTEMS. DO  
NOT CONNECT TO A 6-VOLT OR 24-VOLT BATTERY SYSTEM.  
THIS SYSTEM IS NOT DESIGNED TO BE USED AS A REPLACEMENT FOR A VEHICULAR BATTERY. DO NOT  
ATTEMPT TO JUMPSTART A VEHICLE THAT DOES NOT HAVE A BATTERY INSTALLED.  
VEHICLES THAT HAVE ON-BOARD COMPUTERIZED SYSTEMS MAY BE DAMAGED IF VEHICLE BATTERY IS  
JUMPSTARTED. BEFORE JUMPSTARTING, READ THE VEHICLE’S OWNER’S MANUAL TO CONFIRM THAT  
EXTERNAL–STARTING ASSISTANCE IS ADVISED.  
ALWAYS DISCONNECT THE NEGATIVE (BLACK) JUMPER CABLE FIRST: FOLLOWED BY THE POSITIVE (RED)  
JUMPER CABLE.  
EXCESSIVE ENGINE CRANKING CAN DAMAGE A VEHICLE’S STARTER MOTOR. IF THE ENGINE FAILS TO  
START AFTER THE RECOMMENDED NUMBER OF ATTEMPTS. DISCONTINUE JUMPSTART PROCEDURE AND  
LOOK FOR OTHER PROBLEMS THAT MAY NEED TO BE CORRECTED.  
ALTHOUGH THIS UNIT CONTAINS A NON-SPILLABLE BATTERY, IT IS RECOMMENDED THAT UNIT BE KEPT  
UPRIGHT DURING STORAGE, USE AND RECHARGING. TO AVOID POSSIBLE DAMAGE THAT MAY SHORTEN  
THE UNIT’S WORKING LIFE, PROTECT IT FROM DIRECT SUNLIGHT, DIRECT HEAT, AND/OR MOISTURE.  
CHECK UNIT PERIODICALLY FOR WEAR AND TEAR. REPLACE WORN OR DEFECTIVE PARTS IMMEDIATELY -  
CONTACT VECTOR™ CUSTOMER SERVICE DEPARTMENT AT (954) 923-1155.  
NEVER ALLOW RED AND BLACK CLAMPS TO TOUCH EACH OTHER OR ANOTHER COMMON METAL  
CONDUCTOR—THIS COULD CAUSE DAMAGE TO THE UNIT AND/OR CREATE SPARKING/EXPLOSION  
HAZARD. ALWAYS STORE BATTERY CLAMPS IN BUILT-IN HOLSTERS WHEN NOT IN USE.  
DO NOT EXPOSE BATTERY TO FIRE OR INTENSE HEAT AS IT MAY EXPLODE. BEFORE DISPOSING OF THE  
BATTERY, PROTECT EXPOSED TERMINALS WITH HEAVY-DUTY ELECTRICAL TAPE TO PREVENT SHORTING  
(SHORTING CAN RESULT IN INJURY OR FIRE).  
DO NOT SMOKE OR USE INFLAMMABLE ITEMS (MATCHES, CIGARETTE LIGHTERS, ETC.) WHILE WORKING  
ON A VEHICLE’S BATTERY SYSTEM.  
KEEP UNIT OUT OF REACH OF CHILDREN (WHETHER STORED, OR IN USE).  
DO NOT ATTEMPT TO JUMPSTART A FROZEN BATTERY.  
NEVER SUBMERGE THIS UNIT IN WATER.  
DO NOT USE INVERTER WITH POSITIVE GROUND ELECTRICAL SYSTEMS (THE MAJORITY OF MODERN  
AUTOMOBILES, RVS, AND TRUCKS ARE NEGATIVE GROUND). NOTE: REVERSE POLARITY CONNECTION  
WILL RESULT IN DAMAGE TO THE JUMPSTART SYSTEM.  
FIRST AID:  
SKIN: IF BATTERY ACID COMES IN CONTACT WITH SKIN, RINSE IMMEDIATELY WITH WATER, THEN WASH  
THOROUGHLY WITH SOAP AND WATER. IF REDNESS, PAIN, OR IRRITATION OCCURS, SEEK  
IMMEDIATE MEDICAL ATTENTION.  
THIS UNIT WILL NOT OPERATE APPLIANCES AND EQUIPMENT THAT PRODUCE HEAT, SUCH AS HAIR  
DRYERS, MICROWAVE OVENS, AND TOASTERS.  
EYES: IF BATTERY ACID COMES IN CONTACT WITH EYES, FLUSH EYES IMMEDIATELY—FOR MINIMUM OF  
15 MINUTES—SEEK IMMEDIATE MEDICAL ATTENTION.  
BATTERY REPLACEMENT:  
IT IS RECOMMENDED TO RETURN UNIT TO VECTOR™ CUSTOMER SERVICE FOR BATTERY REPLACEMENT:  
CONTACT (954) 923-1155  
BATTERY DISPOSAL:  
THIS UNIT CONTAINS A MAINTENANCE-FREE, SEALED, NON-SPILLABLE, LEAD ACID BATTERY WHICH  
MUST BE DISPOSED OF PROPERLY. SOME STATES REQUIRE RECYCLING. DISPOSAL QUESTION? IN USA,  
CALL 1-800-RE-USE-PB (783-7372), OR VECTOR CUSTOMER SERVICE DEPARTMENT (954)923-1155.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iii  
1
VEC021/VEC021AC INDUSTRIAL SERIES™ 900 JUMPSTART SYSTEM & POWER SUPPLY  
Congratulations on selecting the Vector™ INDUSTRIAL SERIES™ 900 JUMPSTART SYSTEM & POWER SUP-  
PLY.  
Figure 1.  
Please read this guide carefully before use to ensure optimum performance and avoid damage to the unit or items  
that you are using it with.  
1. 12 VOLT DC CHARGER/  
10.  
1.  
2.  
OUTPUT SOCKET, WITH  
OVERLOAD PROTECTION  
2. SAFETY ON/OFF POWER  
11.  
In addition to a built-in 12-volt power supply, the INDUSTRIAL 900™ JUMPSTART SYSTEM has several exclusive  
features that set it apart from other similar devices. Primarily, it includes a special, built-in mounting (Patent Pending)  
that allows for the simple, slide-in addition of a 110-volt AC power inverter (sold separately for Model VEC021;  
included with Model VEC021AC). This will allow you to upgrade the basic unit to run 110-volt AC devices, while  
still  
3.  
SWITCH (NO KEY REQUIRED)  
3. CHARGE STATUS BUTTON  
4. HEAVY-DUTY #4AWG  
WELDING QUALITY  
maintaining the units one-piece, compact styling.  
JUMPER CABLES  
5. HEAVY-DUTY, 600 AMP  
COPPER CLAMPS  
6. EXCLUSIVE, QUICK-RELEASE,  
SPRING-LOADED CABLE  
HOLSTERS  
5.  
6.  
9.  
The INDUSTRIAL 900™ JUMPSTART SYSTEM is a convenient, easy-to-carry, completely portable system that is per-  
fect for emergency situations and remote locations - when jumpstarting assistance or permanent utility power  
sources are not available. It is also ideal for use with Vector™ 12-volt DC cordless, portable, rechargeable products.  
For easy reference, this manual includes all information and specifications pertaining to the following Vector™  
Model Numbers:  
7. 110 VOLT AC/DC  
CHARGER/POWER CORD  
8. 12-VOLT DC/DC  
CHARGER/POWER CORD  
9. BUILT-IN WORK/  
EMERGENCY LIGHT  
10.WORK/EMERGENCY LIGHT  
ON/OFF SWITCH  
VEC021 INDUSTRIAL SERIES™ 900 JUMPSTART SYSTEM & POWER SUPPLY—Jumpstart System and 12-volt DC  
power supply.  
Note: You can purchase a Vector™ Power Force 150™ inverter (sold separately) to upgrade this model to the  
same capabilities and specifications as the VEC021AC. (Contact Vector™ customer service for your newest retailer).  
Use the VEC021 to:  
-Jumpstart  
Any vehicle with a standard 12-volt DC battery system: boat, truck, car, airplane, RV, personal watercraft,  
snowmobile, tractor, etc.  
-Operate: 12-volt DC  
Fans, inflators, fluorescent work lights, cellular phones*, air compressors, inflators, spotlights, TVs, portable  
radios, cassette or CD players, and more. *Can quick-charge a cellular phone by using the phones 12-volt DC  
adapter cord.  
8.  
4.  
11.L.E.D. CHARGING/BATTERY  
STATUS INDICATORS  
7.  
VEC021AC INDUSTRIAL SERIES™ 900 JUMPSTART SYSTEM & POWER SUPPLY—Jumpstart System and 12-volt  
DC/110-volt AC power supply (this model includes the detachable VEC023 Power Force 150™ inverter). Use the  
VEC021AC as jumpstarter and 12-volt power supply (as above), PLUS:  
Figure 2.  
1. BUILT-IN MOUNTING  
(PATENT PENDING) FOR VEC023  
POWER INVERTER  
2. BUILT-IN CORD STORAGE  
3. LOCK-IN/RELEASE BUTTON  
4. VEC023 150 WATT POWER INVERTER  
SLIDE-IN MOUNTING  
Operate: 110-volt AC  
Laptop computers and printers, fax machines, reading lamps, fans, small appliances and power hand tools (up to  
1.5-amp), and more. Note: You can also Recharge: 110-volt AC: Small 110-volt AC devices (laptop comput-  
ers, cellular phones, camcorders, power tool batteries) that have an appropriate recharging adapter with a 110-volt  
AC standard-type plug.  
VEC023 Power Force 150™ inverter—included with Model VEC021 AC; sold separately for Model VEC021. This  
150/300 watt power inverter is one in a series of the most advanced DC to AC inverters available today, providing  
a convenient, portable source of electricity for running 110-volt AC appliances or accessories in areas where  
permanent utility power is not available. Can be added to Model VEC021 for the additional convenience of a  
110-volt AC power supply. Important information and specifications regarding the inverter are included in the back  
of this manual.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2
3
Figure 4.  
Figure 3.  
IMPORTANT INFORMATION:  
CAUTION: READ INSTRUCTION MANUAL AND PRODUCT LABELING CAREFULLY, FOR COMPLETE  
INSTRUCTIONS, BEFORE USING THIS PRODUCT. FOLLOW RECOMMENDED WARNINGS, CAUTIONS, AND  
SAFETY PROCEDURES, AND MANUFACTURER GUIDELINES FOR YOUR VEHICLE BATTERY.  
1.  
1.  
2.  
IMPORTANT: ALTHOUGH THIS UNIT IS DELIVERED IN A PARTIALLY-CHARGED STATE—YOU MUST FULLY  
CHARGE IT WITH THE SUPPLIED 110-VOLT AC CHARGER FOR A FULL 24 HOURS, BEFORE USING IT FOR THE  
FIRST TIME.  
IMPORTANT: DO NOT OVERCHARGE UNIT, THIS WILL REDUCE BATTERY LIFE. CHARGE ONLY UNTIL  
“CHARGED” INDICATOR IS LIT. AFTER INITIAL CHARGE, LIMIT RECHARGE TIMES TO:  
12-VOLT DC—3-4 HOURS MAX.  
110-VOLT AC—16-20 HOURS MAX.  
• NOTE: AFTER GREEN “CHARGED” INDICATOR LIGHT COMES ON, UNIT CAN BE TOP-OFF CHARGED  
FOR AN ADDITIONAL 2-4 HOURS.  
• FULLY RECHARGE UNIT AFTER EACH USE, OR WHEN CHARGE STATUS INDICATOR SHOWS LOWER THAN  
“FULL”, AND EVERY 2 MONTHS WHEN NOT IN USE.  
• ALWAYS RECHARGE IN A DRY, WELL-VENTILATED AREA, AWAY FROM WATER.  
WHEN CHARGING IN ANY WET OR DAMP AREA FROM A 110-VOLT ELECTRICAL  
OUTLET, MAKE SURE THAT THE OUTLET USED IS PROTECTED BY A GROUND FAULT  
INTERRUPT SWITCH.  
4
2.  
3.  
3.  
5.  
1. INVERTER POWER INDICATOR  
2. INVERTER ON/OFF SWITCH  
1. FIXED CLAMP COVER  
2. CLAMP HOLSTER SHOULDER  
3. SLIDE DOWN & ROTATE  
CLAMP OUTWARD FROM  
BACK OF UNIT TO REMOVE  
3. INVERTER OVERLOAD/LOW BATTERY INDICATOR  
4. STANDARD HOUSEHOLD-TYPE 110-VOLT AC  
POWER SOCKET  
5. 12-VOLT DC CIGARETTE LIGHTER TYPE PLUG  
• WHEN CHARGING THE UNIT NEAR WATER (POOL, DOCKSIDE, BEACH, ETC.) DO NOT ALLOW THE  
ELECTRICAL CORDS AND OUTLETS TO GET WET OR COME NEAR WATER—ELECTRICAL SHOCK  
COULD RESULT!  
• USE ONLY THE SUPPLIED CORDS FOR RECHARGING/OPERATING THIS UNIT.  
• IT IS RECOMMENDED THAT UNIT BE KEPT UPRIGHT DURING USE AND WHEN RECHARGING.  
• WHEN NOT IN USE, STORE UNIT WITH ON/OFF SWITCH TURNED OFF.  
FEATURES:  
• Heavy duty, INDUSTRIAL SERIES™, professional quality  
• Provides INSTANT POWER—whenever, and wherever its needed.  
• Easy-to-use: emergency jumpstarter for cars, trucks, jet skis, snowmobiles, trucks, farm equipment, airplanes,  
boats, RVs (any 12-volt DC battery system).  
SAFETY WARNINGS:  
• Ideal for garage, marina, service station, towing service, airport, farm/ranch, home, tailgate parties, beach,  
picnics, campsite, wilderness, utility power outages, emergency repairs.  
• Sturdy and compact unit provides up to 50 hours of completely portable 12-volt DC power  
• Built-in cigarette lighter-type socket for use with 12-volt DC accessories.  
• Includes exclusive, built-in mounting (Patent Pending) for 110-volt AC power option—simply slide in the VEC023  
150/300 watt inverter (sold separately for VEC021, included in VEC021AC) for safe, portable 110-volt AC  
power supply in any remote location or emergency situation.  
Portable, safe & convenient—goes where extension cords can’t reach and utility power is not available.  
• ON/OFF safety power switch (no key required, no key to get lost!).  
Cordless/rechargeable—includes charging cords for standard 110-volt AC wall socket, and vehicles  
12-volt DC accessory outlet.  
Powerful—400 instantaneous cranking amps; 900 peak amps.  
• Solid-state, automatic operation and built-in circuit protection.  
Safe to use, transport, store.  
• Includes non-spillable, maintenance-free, heavy duty, 17 amp hour sealed battery.  
• Requires no maintenance (other than recharging) for optimum operation.  
• Molded high-impact case is tough and durable.  
• THERE IS A RISK OF EXPLOSIVE GASES BEING RELEASED WHEN BATTERIES ARE IMPROPERLY CHARGED OR  
DISCHARGED. FAILURE TO FOLLOW INSTRUCTIONS MAY CAUSE PROPERTY DAMAGE, EXPLOSIVE HAZARD,  
AND/OR PERSONAL INJURY.  
• ALWAYS USE PROTECTIVE EYEWEAR WHEN USING THIS PRODUCT: CONTACT WITH BATTERY ACID MAY  
CAUSE BLINDNESS AND/OR SEVERE BURNS.  
• KEEP OUT OF REACH OF CHILDREN.  
• ALWAYS STORE BATTERY CLAMPS IN BUILT-IN HOLSTERS WHEN NOT IN USE. NEVER TOUCH BATTERY  
CLAMPS TOGETHER - THIS CAN CAUSE DANGEROUS SPARKS, POWER ARCING, AND/OR EXPLOSION.  
FIRST AID:  
SKIN: IF BATTERY ACID COMES IN CONTACT WITH SKIN, RINSE IMMEDIATELY WITH WATER, THEN WASH  
THOROUGHLY WITH SOAP AND WATER. IF REDNESS, PAIN, OR IRRITATION OCCURS, SEEK  
IMMEDIATE MEDICAL ATTENTION.  
EYES: IF BATTERY ACID COMES IN CONTACT WITH EYES, FLUSH EYES IMMEDIATELY—FOR MINIMUM OF  
15 MINUTES—SEEK IMMEDIATE MEDICAL ATTENTION.  
Heavy duty, industrial grade copper clamps and #4AWG jumper cables—with exclusive  
spring-loaded, quick-release storage holsters.  
• 110-volt AC charger is Underwriter Laboratories safety tested and listed.  
• Easy-to-read L.E.D. battery charging/status indicators.  
• Built-in work/emergency light for roadside repairs and remote locations without utility power.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
4
1. INTRODUCTION  
2. USING THE INDUSTRIAL 900™ AS A JUMPSTART SYSTEM  
The Vector™ INDUSTRIAL SERIES™ 900 JUMPSTART SYSTEM & POWER SUPPLY is a compact, durable and  
portable jump start system for vehicles and boats that have a standard 12-volt DC battery system. This self-con-  
tained, rechargeable system will start most vehicles and boats without the need for a host vehicle or 110-volt AC  
power supply. It can also be used as a safe, portable source of 12-volt DC electric power in remote locations  
and/or emergency  
situations. When used together with a Vector™ Power Force 150™-watt power inverter (sold separately for  
Model VEC021; included with model VEC021AC) the INDUSTRIAL 900™ will also provide a completely portable  
source of 110-volt AC electric power.  
CAUTIONS:  
• Before using this system to jump start any vehicle or boat, read and understand all instructions, safety tips,  
warnings and cautions, and first aid information provided in this manual and on the product labeling.  
Additional important information may also be provided by the vehicle ‘s battery system manufacturer.  
• BE AWARE OF FIRST AID PROCEDURES BEFORE ATTEMPTING JUMPSTART PROCEDURE.  
• ALWAYS wear protective eyewear when working with a lead acid-type battery.  
• DO NOT smoke or use inflammable items (matches, cigarette lighters, etc.) while working on a vehicle ‘s  
battery system.  
• When using this vehicle in proximity to the vehicle ‘s battery and engine, stand the unit on a flat, stable surface,  
and be sure to keep all cords and cables well away from any moving parts.  
• Check unit periodically for wear and tear. Replace worn or defective parts immediately - contact Vector™  
Customer Service Department at (954) 923-1155.  
The INDUSTRIAL 900™ has an easy-to-read, L.E.D. (Light Emitting Diode) indicator that shows when the unit is fully  
charged, or the level of charge in the battery. A 12-volt DC cigarette lighter-type socket is provided for use with  
appliances that can operate from a vehicle cigarette lighter. This allows maximum portability and utility when the  
INDUSTRIAL 900™ is used in remote locations.  
• Do not attempt to jumpstart a frozen battery.  
• NEVER submerge this unit in water.  
For maximum convenience, the Vector™ INDUSTRIAL 900™ can be recharged from any standard 110-volt AC or  
12-volt DC power source using the built-in 12-volt socket and the appropriate charging/adapter cord. When  
depressed, the PUSH FOR STATUS switch will show the battery ‘s power level status (from Low to Full). The green  
L.E.D. CHARGED indicator illuminates when the unit is fully recharged. An ON/OFF switch operates the built-in  
work/emergency light.  
• Do not wear vinyl clothing when jumpstarting a vehicle—friction can cause dangerous static electricity sparks.  
Remove all jewelry or metal objects—they can cause short circuits or react with battery acid to cause severe  
burns. Remove or secure any loose clothing items, and restrain long hair, before attempting jumpstart procedure.  
WARNINGS:  
• Vehicles that have on-board computerized systems may be damaged if vehicle battery is jumpstarted. Before  
jumpstarting this type of vehicle, read the vehicle‘s owner‘s manual to confirm that external-starting assistance  
is advised.  
• Excessive engine cranking can damage the vehicle ‘s starter motor. If the engine fails to start after the  
recommended number of attempts, discontinue jumpstart procedure and look for other problems that may  
need to be corrected.  
WARNING:  
Lead-acid batteries generate hydrogen gas during normal operation. More gas is generated when the battery is  
charging. Hydrogen gas is:  
1. Explosive  
2. Poisonous to breathe  
3. Highly flammable  
2.1 EASY, STEP-BY-STEP JUMPSTARTING INSTRUCTIONS  
To avoid an explosion and/or the possibility of being splashed with battery acid:  
• NEVER allow the red and black clamps to touch each other or a common metal object.  
• ONLY attempt to jumpstart a vehicle or boat in a WELL ventilated area.  
• ALWAYS CONNECT THE RED (+) CLAMP TO THE POSITIVE (+) BATTERY TERMINAL FIRST.  
• DO NOT CONNECT THE BLACK (-) CLAMP TO THE NEGATIVE (-) BATTERY TERMINAL.  
• DO CONNECT THE BLACK (-) CLAMP TO A NON-MOVING METAL PART ON THE ENGINE.  
1. Turn OFF vehicle ignition and all accessories (radio, a/c, lights, cell phone, etc.). Place  
vehicle in “park” and set the emergency brake.  
2. Make sure jumpstart system power switch is turned OFF.  
3. Follow procedure for negative or positive grounded system, as follows:  
NEGATIVE GROUNDED SYSTEM (NEGATIVE BATTERY TERMINAL IS CONNECTED TO  
CHASSIS—MOST COMMON METHOD:  
• TO REMOVE BOOSTER CLAMPS FROM PROTECTIVE HOLSTER (FIG. 3): SIMPLY PULL DOWN  
ON CLAMP, (SHOULDER REST IS SPRING LOADED)—ROTATE TOP OF CLAMP OUTWARD  
WHILE YOU PULL DOWN—WHEN CLEAR OF CLAMP COVER REMOVE CLAMP.  
TO REPLACE BOOSTER CLAMP INTO PROTECTIVE HOLSTER—RETURN CLAMP TO SHOULDER  
REST, ROTATE OUT AND PUSH DOWN THEN SLIDE CLAMP UP INTO PROTECTIVE COVER.  
• CONNECT POSITIVE (+) RED CLAMP TO VEHICLE BATTERY ‘S POSITIVE TERMINAL.  
• CONNECT NEGATIVE (-) BLACK CLAMP TO CHASSIS OR A SOLID, NON-MOVING, METAL  
VEHICLE COMPONENT OR BODY PART. NEVER CLAMP DIRECTLY TO NEGATIVE BATTERY  
TERMINAL OR MOVING PART.  
CAUTIONS:  
I. To avoid possible damage that may shorten the units working life, protect this unit from direct sunlight,  
direct heat, and/or moisture.  
2. This system is designed to be used ONLY on vehicles or boats with 12-volt DC battery systems.  
3. This system is NOT designed to be used as a replacement for a vehicular battery.  
RECOMMENDATIONS FOR OPTIMUM PERFORMANCE OF THE INDUSTRIAL 900™ JUMPSTART SYSTEM:  
WARNING: NEVER insert anything other than the supplied power/recharging cords or recommended  
appliance power/recharging cords into the charging/power sockets on this unit.  
4. Turn jumpstart system ‘s power switch to ON position.  
5. Start vehicle (do not turn key for longer than 5-6 seconds).  
IMPORTANT: The safety ON/OFF switch should be in the OFF position when the unit is charging, or not in use.  
6. After vehicle starts, turn jumpstart system ‘s power switch to OFF position. Remove  
clamps (disconnect the negative (Black) jumper cable first; followed by the positive  
(Red) jumper cable) and replace them in the built-in storage holsters.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
7
NOTE: In the rare event that the vehicle to be started has a Positive Grounded System  
(positive battery terminal is connected to chassis): Replace steps I and 2 above  
with the following steps, and then proceed to steps 4-6 above.  
1. Connect negative (-) black clamp to vehicle battery ‘s negative terminal.  
2. Connect positive (+) red clamp to vehicle chassis or a solid, non-moving, metal  
vehicle component or body part. DO NOT clamp directly to positive battery terminal  
or moving part.  
3. EMERGENCY/WORK LIGHT  
Bulb Replacement  
To turn work light on or off, simply toggle the switch on the front control panel.  
1.Replacement bulbs are available from Vector™ Customer Service Department; call (954) 923-1155.  
2.Remove the lens cover, two phillips type screws—snap out cover.  
3.Remove the burned-out bulb.  
4.Replace with a new bulb (12-volt 0.7 amp Krypton bulb).  
5.Snap the lens cover back into place and replace the two screws—DO NOT OVER-TIGHTEN.  
CAUTIONS:  
• If vehicle fails to start, leave vehicle ignition key turned OFF, turn INDUSTRIAL 900™ power  
switch to off, disconnect the negative (-) clamp first, then the positive (+) clamp, and  
discontinue jumpstarting procedure.  
4. CHARGING/RECHARGING  
• Recharge jumpstart system after each use.  
4.1 110-Volt AC Charging  
IMPORTANT:  
• MAKE SURE SAFETY ON/OFF SWITCH IS IN OFF POSITION DURING RECHARGING.  
• Charge unit for full 24 hours, prior to first use.  
• Recharge unit fully after each use.  
WARNINGS:  
• ALWAYS disconnect the negative (Black) jumper cable first; followed by the positive (Red)  
jumper cable.  
• NEVER ALLOW RED AND BLACK CLAMPS TO TOUCH EACH OTHER OR ANOTHER COMMON  
METAL CONDUCTOR—THIS COULD CAUSE DAMAGE TO THE UNIT AND/OR CREATE A SPARK  
AND EXPLOSION.  
• Recharge unit every two months, when it has not been used.  
• There is a risk of explosive gases being released when batteries are improperly charged  
or discharged. Failure to follow instructions may cause property damage, explosive  
hazard, and/or personal injury.  
• ALWAYS USE PROTECTIVE EYEWEAR WHEN USING THIS PRODUCT: CONTACT WITH BATTERY  
ACID MAY CAUSE BLINDNESS AND/OR SEVERE BURNS.  
• Keep out of reach of children.  
• ALWAYS store battery clamps in built-in holsters when not in use. Never touch battery  
clamps together—this can cause dangerous sparks, power arcing, and/or explosion.  
1.Simply plug the 110-volt AC plug (Fig. 5 #1) of the AC/DC adapter/charger cord into any standard  
110/120-volt AC wall outlet.  
2.Plug the 12-volt DC cigarette type plug (Fig. 5 #2) into the 12-volt DC receptacle on the unit.  
3.Charge this device for at least 14-16 hours or until the FULL indicator is lit.  
4.NOTE: The unit can be overcharged (which will shorten the life of the battery)—DO NOT charge with AC  
charging procedure for more than 24 hours maximum.  
5.Remove the power cord and store in a safe place.  
6.When the 110-volt power inverter option is installed on the unit, the inverter ‘s ON/OFF switch must be in  
the OFF position during recharging.  
FIRST AID:  
Skin: If battery acid comes in contact with skin, rinse immediately with water, then wash thoroughly with soap  
and water. If redness, pain, or irritation occurs, SEEK IMMEDIATE MEDICAL ATTENTION.  
Eyes: If battery acid comes in contact with eyes, flush eyes immediately—for minimum of 15 minutes—SEEK  
IMMEDIATE MEDICAL ATTENTION.  
Figure 5.  
3.  
1.  
12-VOLT DC/DC  
CHARGING CORD  
2.2 BATTERY REPLACEMENT  
IT IS RECOMMENDED TO RETURN UNIT TO VECTOR™ CUSTOMER SERVICE FOR BATTERY REPLACEMENT:  
CONTACT (954) 923-1155  
110-VOLT AC/DC  
ADAPTER/CHARGER  
2.3 BATTERY DISPOSAL  
Contains a maintenance-free, sealed, non-spillable, lead acid battery which must be disposed of properly. Most  
states require recycling—contact your local authority for information.  
4.  
2.  
SEALED LEAD BATTERY, MUST BE RECYCLED OR DISPOSED OF PROPERLY, DISPOSAL QUESTION?  
FOR USA CALL 1-800-RE-USE-PB (738-7372) OR VECTOR™ CUSTOMER SERVICE.  
WARNINGS:  
4.2 12-Volt DC Charging  
DO NOT DISPOSE OF THE BATTERY IN FIRE AS THIS MAY RESULT IN AN EXPLOSION.  
BEFORE DISPOSING OF THE BATTERY, PROTECT EXPOSED TERMINALS WITH HEAVY-DUTY  
ELECTRICAL TAPE TO PREVENT SHORTING (SHORTING CAN RESULT IN INJURY OR FIRE).  
DO NOT EXPOSE BATTERY TO FIRE OR INTENSE HEAT AS IT MAY EXPLODE.  
The INDUSTRIAL 900™ system also comes with a DC/DC charging cord, for recharging the unit from the 12-volt  
DC cigarette lighter socket in a vehicle or boat. Note: This recharging method will NOT recharge the unit as  
effectively as recharging from a 110-volt AC outlet. The 12-volt DC recharging procedure is recommended only  
when it is necessary, as continued use of the 12-volt DC recharging procedure may shorten the battery systems life.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
9
WARNING: DO NOT RECHARGE FOR MORE THAN 3-4 HOURS MAXIMUM USING 12-VOLT DC METHOD.  
1.NOTE: If unit is fully discharged, it is recommended that the vehicle being used for recharging be left running  
while the unit is being charged via the 12-volt DC method.  
2.Insert one end of the DC/DC charging cord into the 12-volt DC cigarette lighter receptacle on the vehicle  
or boat. See Fig. 5 #3.  
3.Insert the plug at the other end of this power cord (Fig. 5 #4) into the 12-volt DC receptacle on the front panel  
of the unit.  
4.Charge the unit until the green CHARGED indicator is lit—DO NOT EXCEED 3-4 HOURS MAXIMUM.  
5.Remove the power cord and store in a safe place.  
5.1 To Use The Industrial 900™ System As A 12-Volt DC Portable  
Power Supply  
1.NOTE: Make sure that the unit ‘s safety ON/OFF switch is ALWAYS in the OFF position when using the  
12-volt DC accessory outlet.  
2.Lift up the cover of the unit ‘s 12-volt DC cigarette lighter-type receptacle.  
3.Insert the 12-volt DC plug from the appliance into the receptacle on the unit.  
4.Switch on the appliance, as usual.  
CAUTION: DO NOT USE THIS UNIT TO OPERATE APPLIANCES THAT DRAW MORE THAN 15 AMPS.  
4.3 Recharging  
1.For maximum battery life, we recommend that the INDUSTRIAL 900™ system be kept fully charged at all times. If  
the battery is allowed to remain in a discharged state, battery life may be shortened.  
Note: Recharging battery after each use will prolong battery life; frequent discharges between recharges will reduce  
battery life. Table I shows the relationship of the frequency of use between recharging and the expected number of  
discharge/recharge cycles.  
Table III shows the estimated 12-volt DC operation times when using a fully-charged system.  
TABLE III. - INDUSTRIAL 900™ AS A 12-VOLT DC POWER SUPPLY  
APPLIANCE TYPE  
ESTIMATED POWER  
ESTIMATED USAGE  
TIME (IN HOURS)  
CONSUMPTION (IN WATTS)  
TABLE I. - ESTIMATED BATTERY LIFE  
CELL PHONE  
FLUORESCENT LIGHT  
RADIO, FAN, DEPTH FINDER  
CAMCORDER, VCR, SPOTLIGHT  
POWER TOOLS, BILGE PUMP  
ELECTRIC COOLER  
3
4
9
15  
24  
48  
80  
35  
30  
21  
12  
7
AVERAGE NUMBER OF USES  
(JUMPSTART OR DISCHARGES)  
BETWEEN RECHARGES  
POTENTIAL TOTAL NUMBER  
OF JUMPSTART OR DISCHARGE CYCLES  
(LIFETIME OF UNIT BATTERY)  
3
1.5  
AIR COMPRESSOR, CAR VACUUM  
1 . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000+  
5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700+  
10 . . . . . . . . . . . . . . . . . . . . . . . . . . . 500+  
NOTE:ALL TIMES ARE APPROXIMATE, AND BASED UPON FULLY CHARGED UNIT.  
2.The time  
required to fully  
recharge the INDUSTRIAL 900™ system after jumpstarting an engine depends on how  
many jumpstarts are performed between recharging sessions. Table II shows the approximate recharging times  
to be expected.  
5.2 To Use The Industrial 900™ System As A 110-Volt AC  
Power Supply  
TABLE II. - ESTIMATED RECHARGING TIMES BASED ON NUMBER OF JUMPSTARTS  
(OR DISCHARGES) PERFORMED SINCE LAST FULL CHARGING  
1. IMPORTANT: Before using the unit as a 110-volt power supply, read the complete instructions, information and  
troubleshooting tips, pertaining to the inverter, in the back of this manual.  
2. Make sure that the inverter ‘s power switch is in the OFF position before recharging or making any connection  
to power source or load.  
NUMBER OF  
RECHARGING  
NUMBER OF  
RECHARGING  
JUMPSTARTS . . . . . . TIME (IN MINUTES)  
JUMPSTARTS.............TIME (IN MINUTES)  
3. Line up the body housing on the Vector™ Power Force 150™ inverter (sold separately for Model VEC021;  
included with Model VEC021AC) with the mounting walls on the back of the INDUSTRIAL 900™. Slide the  
inverter into place, from right to left. See Fig. (2) #4.  
1 . . . . . . . . . . . . . . . . 8  
2 . . . . . . . . . . . . . . . . 16  
3 . . . . . . . . . . . . . . . . 24  
4....................................32  
5 ...................................40  
6....................................48  
4. Note the convenient built-in cord storage above the inverter mounting.  
5. NOTE: Once inverter is properly in place, lock-in tab button will pop up, see Fig. (2) #3 (depress tab button  
to release and remove inverter).  
6. Remove the inverter‘s adapter cord from its storage compartment, and plug the cigarette lighter-type tip into  
the 12-volt DC receptacle on the front of the unit.  
3.Note: Check the battery charge level by depressing the PUSH FOR STATUS switch. The L.E.D. display will show  
the level of the battery ‘s charge.  
7. Plug the appliance‘s 110-volt plug into the corresponding socket on the inverter.  
8. Turn the inverter power switch to ON.  
9. Turn the appliance on, and operate as normal.  
10. After use, unplug the inverter‘s adapter cord from the front of the unit and replace in the storage compartment.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10  
11  
CAUTION: RECHARGEABLE APPLIANCES  
8. OPTIONAL VEC023 POWER FORCE 150™ WATT INVERTER FOR  
USE WITH THE INDUSTRIAL SERIES™ 900 JUMPSTART SYSTEM &  
POWER SUPPLY:  
Certain rechargeable devices are designed to be recharged by plugging them directly into an AC receptacle. These  
devices may damage the Power Force 150™. When first using a rechargeable device, monitor its temperature for  
the initial ten minutes of use to determine whether it emits excessive heat. If excessive heat is detected, it is a good  
indication that the device should not be used with this inverter. This problem does not occur with the majority of  
battery-operated equipment. Most of these devices use a separate charger or transformer that is plugged into an  
AC receptacle. The Power Force 150™ is easily capable of running most chargers and transformers.  
VEC023 Power Force 150™ Inverter—Included with Model VEC021AC; and sold separately as an  
optional accessory for use with Model VEC021.  
NOTE: The following information applies only to the inverter as it is used in conjunction with the INDUSTRIAL  
900™.  
Table IV shows the estimated 110-volt AC operation times when using a fully-charged system.  
If the inverter is purchased together with the VEC021AC or separately, a full manual (detailing the independent use  
of the inverter) is supplied.  
TABLE IV. Using the INDUSTRIAL 900™ AS A 110-VOLT AC POWER SUPPLY  
APPLIANCE TYPE  
CONSUMPTION (IN WATTS)  
ESTIMATED POWER  
TIME (IN WATTS)  
ESTIMATED USAGE  
Features:  
CELLULAR PHONE/CAMCORDER/  
POWER TOOL CHARGERS  
LAPTOP COMPUTER, PRINTER,  
LAMP, FAN, VCR, WORKLIGHT,  
RADIO/CASSETTE/CD PLAYER,  
SUMP PUMP  
50 WATTS  
4.0-6.0 HOURS  
3.0 HOURS  
• The Power Force 150™ inverter provides a portable power source to run a variety of 110-volt devices equipped  
with standard household-type plugs.  
• The Power Force 150™ inverter is easily attached to (or removed from) the rear of the INDUSTRIAL 900™.  
The exclusive mounting (Patent Pending) is neat and convenient, maintaining the original single-unit integrity  
of the product.  
• Using the Power Force 150™ inverter with the INDUSTRIAL 900™ does not reduce the efficiency of either  
device,  
90 WATTS  
100 WATTS  
140 WATTS  
1.5 HOURS  
1 HOUR  
FAX, TV, SMALL POWER TOOL  
or their portability.This combined unit provides the convenience of a 12-volt DC / 110-volt AC Power Supply and  
NOTE: ALL TIMES ARE APPROXIMATE, AND BASED UPON FULLY CHARGED UNIT.  
a completely portable, rechargeable emergency Jumpstart System, in one compact unit.  
• The Power Force 150™ inverter can be stored permanently in place on the INDUSTRIAL 900™, or stored sepa-  
rately  
6. SPECIFICATIONS  
and quickly connected as needed.  
Model ....................................................................VEC021  
Voltage ..................................................................12 VDC  
Boost Power ...........................................................400 Instantaneous  
Cranking Amps  
VEC021AC  
• The Power Force 150™ inverter can also be used independently of the INDUSTRIAL 900™ as a 110-volt AC  
power  
supply (use in conjunction with your vehicle). For instructions, refer to the inverter ‘s full manual (supplied, when  
the inverter is purchased separately) or call Vector™ Customer Service Department at (954) 923-1155 to obtain  
a copy.  
12 VDC/110 VAC  
400 Instantaneous  
Cranking Amps  
900 Amps  
Peak Ampere Power ...............................................900 Amps  
Battery Type .......................................................... Sealed, lead- acid, rechargeable, maintenance-free,  
12-volt DC,17.5-Ampere-hours  
Bulb ...........................................................................................12-volt 0.7 amp Krypton  
Booster Cables ..................................................................................#4AWG welding  
Booster Clamps ...........................................................................600 AMP copper clamps  
The Vector Power Force 150™ inverter is one in a series of the most advanced DC to AC inverters available today.  
With proper care and appropriate usage, it will provide years of dependable service in your car, truck, RV, boat or  
even airplane.  
For easy reference, see the following sections titled:  
8.1 Introduction  
HEIGHT ....................................................................................... 11-3/4” (29.85CM)  
DEPTH ......................................................................................... 6-1/4” (15.88CM)  
WIDTH ........................................................................................ 11-5/8” (29.53CM)  
WEIGHT ...................................................................................... 18LBS. (8.16KG)  
8.2 How the Power Force 150™ Inverter Works  
8.3 Installation  
8.4 Operating Tips  
VEC023/150 Watt Power Inverter  
Optional  
Included  
8.5 Troubleshooting  
8.1 INTRODUCTION:  
7. REPLACEMENT PARTS  
The Power Force 150™ supplies 150 watts of continuous power, with a 300 watt peak, in the form of a household-  
type outlet that is ready to deliver 110-volt AC power whenever and wherever you need it! Simply plug  
the inverter directly into the INDUSTRIAL 900™ 12-volt DC socket to provide 110-volt AC power for almost any  
small household or electronic appliance including: color TVs (up to 10”); VCRs; portable radios/boom boxes/  
CD players; laptop computers, printers, fax machines; camcorder, cellular phone and power tool chargers; lamps  
(up to 100 watts); light duty power tools (up to 1.5amps); and much more. The inverter ‘s AC receptacle is fully  
marinized, weatherproof and fused. Added safety features include automatic shutdown and a low battery alarm  
to prevent damage to the unit ‘s main battery.  
For replacement parts (bulbs, batteries, fuses, etc.), contact Vector™ Customer Service: (954) 923-1155.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
13  
To ensure years of reliable service, the power inverter must be installed and used properly. Please read the  
installation and operating instructions thoroughly prior to installation and use. Pay particular attention to the  
CAUTION and WARNING statements in this manual. The CAUTION statements advise against certain conditions  
and practices that may result in damage to the INDUSTRIAL 900™ and/or the inverter. The WARNING statements  
identify conditions or practices that may result in personal injury or loss of life.  
Example: If a load is rated at 100 watts, the power source must be able to deliver:  
100 ÷ 10 = 10 amperes  
CAUTION: The Power Force 150™ must only be connected to batteries with a nominal output voltage of  
12-volts DC. The unit will not operate from a 6-volt battery and will sustain permanent damage if connected to a  
24-volt battery.  
8.2 HOW THE VECTOR™ Power Force 150™ INVERTER WORKS  
8.3.2 Connecting To Power Source  
The Power Force 150™ inverter is an electronic device that converts low voltage DC (direct current) electricity from  
a 12-volt DC vehicle battery or other 12-volt DC power source (like the INDUSTRIAL 900™ system) to standard  
110-volt AC (alternating current) household power. In designing the Power Force 150™, Vector™ has incorporated  
design techniques previously employed in computer power supplies. The result of these design innovations is a  
smaller, lighter and easier-to-use power inverter.  
The Power Force 150™ is equipped with a cigarette lighter-type plug for connecting it to the INDUSTRIAL 900™.  
The tip of the plug is positive and the side contact is negative. Simply insert the plug firmly into the 12-volt DC  
socket on the front of the INDUSTRIAL 900™.  
CAUTION—REVERSE POLARITY CONNECTION WILL RESULT IN DAMAGE TO THE INVERTER.  
8.2.1 Vector™ Power Force 150™ Inverter—Principle Of Operation  
If the inverter is connected to the incorrect polarity, the fuse will be blown. If the unit does not function after  
replacement of the fuse, the unit must be returned to Vector for repair. Repair expenses for this type of damage are  
not covered by your warranty.  
The Power Force 150™ inverter converts power in two stages. The first stage is a DC-to-DC conversion process that  
raises the low voltage DC at the inverter input to 14.5-volts DC. The second stage is the actual inverter stage that  
converts the high voltage DC into 110-volts, 60 Hz AC.  
CAUTION: DO NOT USE WITH POSITIVE GROUND ELECTRICAL SYSTEMS.  
(THE MAJORITY OF MODERN AUTOMOBILES, RVs, AND TRUCKS ARE NEGATIVE GROUND)  
The DC-to-DC converter stage uses modern high frequency power conversion techniques that have replaced  
the bulky transformers found in less technologically-advanced models. The inverter stage uses advanced power  
MOSFET transistors in a full bridge configuration. This ensures excellent overload capability and the ability to  
operate reactive loads like lamp ballasts and small induction motors.  
8.3.3 Connection To Load  
Make sure that the ON/OFF switch on the inverter is in the OFF position. Remove the inverter ‘s power cord  
from its storage compartment and connect the Power Force 150™ to the 12-volt DC socket on the front of the  
INDUSTRIAL 900™. Leave the ON/OFF switch on the INDUSTRIAL 900™ in the OFF position, and then turn the  
inverter‘s ON/OFF switch to the ON position. The inverter ‘s green LED indicator will illuminate to indicate that  
the unit is functioning. Make sure the load requirements of your equipment are within the parameters of the  
Power Force 150™ output. If so, plug the appliance into the standard household-type AC outlet on the inverter and  
turn ON your equipment. If an audible alarm sounds, refer to the Troubleshooting section of this manual for  
probable causes and recommendations.  
8.2.2 Power Force 150™ Output Waveform—Modified Sine Wave  
The AC output waveform of the Power Force 150™ is known as a “quasi-sine wave” or a “modified sine wave”. It  
is a stepped waveform that is designed to have characteristics similar to the sine wave shape of utility power. This  
type of waveform is suitable for most AC loads, including linear and switching power supplies used in electronic  
equipment, transformers, and motors.  
The modified sine wave produced by the Power Force 150™ inverter is designed to have an RMS (root mean  
square) voltage of 115-volts, which is the same as standard household power. Most AC voltmeters ( both digital and  
analog) are sensitive to the average value of the waveform rather than the RMS value. They are calibrated for RMS  
voltage under the assumption that the waveform measured will be a pure sine wave. These meters will not read the  
RMS voltage of a modified sine wave correctly. They will read about 20 to 30 volts low when measuring the output  
of the Power Force 150™. For accurate measurement of the output voltage of this unit, use a true RMS reading  
voltmeter such as a Fluke 87, Fluke 8060A, Beckman 4410, or a Triplett 4200.  
DO NOT CONNECT TO AC DISTRIBUTION WIRING: The Power Force 150™ is engineered to be connected  
directly to standard electrical and electronic equipment in the manner described above. Do not connect the Power  
Inverter to household or RV AC distribution wiring. Do not connect the Power Inverter to any AC load circuit in  
which the neutral conductor is connected to ground (earth) or to the negative of the DC (battery) source.  
CAUTION: RECHARGEABLE APPLIANCES  
Certain rechargeable devices are designed to be recharged by plugging them directly into an AC receptacle. These  
devices may damage the Power Force 150™. When first using a rechargeable device, monitor its temperature for  
the initial ten minutes of use to determine whether it emits excessive heat. If excessive heat is detected, it is a good  
indication that the device should not be used with this inverter. This problem does not occur with the majority of  
battery-operated equipment. Most of these devices use a separate charger or transformer that is plugged into an  
AC receptacle. The Power Force 150™ is easily capable of running most chargers and transformers.  
8.3 INSTALLATION  
1.See Fig. (2) #4 on page 1 of this manual (Using the INDUSTRIAL 900™ as a 110-volt Power Supply).  
2.Make sure that the inverter ‘s power switch is in the OFF position before making any connection to power  
source or load.  
3.Line up the housing on the Vector™ Power Force 150™ inverter (sold separately for Model VEC021;  
included with Model VEC021AC) with the mounting walls on the back of the INDUSTRIAL 900™. Slide the invert-  
er  
8.3.4 Fuse Replacement  
into place, from right to left. See Fig.(2) #4.  
If the Power Force 150™ is overloaded and the spade type fuse (30A) is blown, flip up the fuse replacement cover  
on the back of the Power Force 150™ and replace the blown fuse with a new spade type, 30 Amp fuse, available  
from Vector™ Customer Service Department (954) 923-1155. Determine the cause of the short before restarting the  
Power Force 150™ again. Fuse Replacement in automobile (only applies when using inverter direct from vehicle):  
Most automobile cigarette lighter circuits use fuses at 15 Amps or less. In order to maximize the output of your  
Power Force 150™ and minimize the possibility of shutdown due to a blown fuse in your vehicle, it may be neces-  
sary to replace the existing fuse in your automobile cigarette lighter circuit with a minimum 15 amp fuse. This fuse  
amperage change will not affect performance or any other aspect of this circuit.  
4.Note the convenient built-in cord storage above the inverter mounting.  
5.NOTE: Once inverter is properly in place, lock-in tab button, then on the right will pop up (depress tab button to  
release and remove inverter).  
8.3.1 Power Source Requirements  
The power source must provide between 11 and 14.5-volts DC and must be able to supply the necessary current to  
operate the load. The INDUSTRIAL 900™ contains a 12-volt DC 17 amp hour maintenance-free sealed lead acid  
battery. To obtain a rough estimate of the current (in amperes) required to operate a particular device (load), simply  
divide the power consumption of the load (in watts) by 10.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
15  
8.3.5 Placement Of The Power Force 150™  
For best operating results, the inverter should be properly installed (as directed in this manual) in the  
8.5 TROUBLESHOOTING  
INDUSTRIAL 900™. The combined unit should only be used in locations that meet the following criteria:  
8.5.1 Protective Features of the Power Force 150™  
The Power Force 150™ monitors the following potentially hazardous conditions:  
DRY—Do not allow water or other liquids to come into contact with unit.  
Low Battery Voltage - This condition is not harmful to the inverter but could damage the INDUSTRIAL 900™.  
An audible alarm will sound when input voltage drops to 10.6. The Power Force 150™ automatically shuts  
down when input voltage drops to 10.0-volts. The INDUSTRIAL 900™ must be fully recharged. Then the unit  
may be restarted.  
COOL—Ambient air temperature should be between -20° C and 40° C—ideally between 15° C and 25° C  
(60 - 80° F). Do not place the unit on or near a heating vent or any piece of equipment which is generating heat  
above room temperature. Keep the unit away from direct sunlight, if at all possible.  
VENTILATED—Keep the area surrounding the Power Force 150™ clear to ensure free air circulation around the  
Over Voltage Protection—The Power Force 150™ will automatically shut down when the input voltage exceeds  
15-volts DC.  
unit.  
Do not place items on or over the inverter during operation. A fan is helpful if the inverter is operating at maximum  
power outputs for extended periods of time. The unit will shut down if the internal temperature exceeds 90° C.  
Restart the unit once it cools down sufficiently.  
Short Circuit Protection—Reverse polarity or a short circuit condition will usually result in the fuse being blown.  
Immediately disconnect the shorted load and replace the fuse of the Power Force 150™ as described in the  
VEC023 Power Force 150™ operation manual.  
SAFE—Do not use the unit near flammable materials or in any locations that may accumulate flammable fumes  
or gases.  
Overload Protection—The inverter will automatically shut down when the continuous draw exceeds 150 watts.  
8.4 OPERATING TIPS  
Over Temperature Protection—When the temperature sensor inside the Power Force 150™ reaches 150° F, the unit  
will automatically shut down. Allow the unit to cool for at least 15 minutes before restarting after a heat-related  
shutdown. Unplug unit while cooling.  
8.4.1 Rated versus Actual Current Draw of Equipment  
Most electrical tools, appliances and audio/video equipment have labels that indicate the power consumption in  
amps or watts. Be sure that the power consumption of the item you wish to operate is rated at 200 watts or less.  
(If the power consumption is rated in amps, simply multiply by the AC volts (110) to determine the wattage).  
CAUTION: LOW BATTERY ALARM  
An alarm will sound when the voltage from the battery drops to 10.6-volts. This is an indication that the battery  
needs to be recharged. STOP OPERATION OF THE ELECTRONIC DEVICE IMMEDIATELY since the Power  
Force 150™ will shut down automatically shortly thereafter, when the battery voltage drops to 10-volts. Recharge  
Example: AMPS (1) X VOLTS (110) = 110 WATTS  
The inverter has overload protection, so it is safe to try to operate equipment rated at 200 watts or less. The  
inverter will shut down if is overloaded, and will restart once the overload is rectified.  
the INDUSTRIAL 900™, per the instructions in this manual.  
8.5.2 Common Problems  
“Buzzing” sound in audio systems  
Some inexpensive stereo systems and “boom boxes” emit a buzzing sound from their speakers when operated from  
the Power Force 150™ power inverter. This occurs because the power supply in the electronic device does not  
adequately filter the modified sine wave produced by the Power Force 150™. The only solution to this problem is  
to use a sound system that incorporates a higher quality power supply.  
Resistive loads are the easiest for the Power Force 150™ to run; however, larger resistive loads, such as electric  
stoves or heaters, usually require more wattage than the Power Force 150™ can deliver on a continuous basis.  
Inductive loads, such as TVs and stereos, require more current to operate than do resistive loads of the same  
wattage rating. Induction motors, as well as some televisions, may require 2 to 6 times their wattage rating to start  
up. The most demanding in this category are those that start under load, such as compressors and pumps. Testing is  
the only definitive way to determine whether a specific load can be started and how long it can run. The unit will  
simply shut down if it is overloaded. To restart the unit after a shutdown due to overloading, momentarily turn off  
the power to the unit.  
Television Interference  
The Power Force 150™ is shielded to minimize interference with TV signals. However, in some instances, some  
interference may still be visible, particularly with weak TV signals. Try the following corrective measures:  
Position the unit as far as possible from the television, the antennae and the antennae cables. Use an extension  
cable, if necessary. Adjust the orientation of the unit, the antennae cables and the TV power cord to minimize  
interference. Make sure that the antennae feeding the television provides an adequate (“snow free”) signal and that  
high quality, shielded antennae cable is used.  
THIS UNIT WILL NOT OPERATE APPLIANCES AND EQUIPMENT THAT PRODUCE HEAT, SUCH AS  
HAIR DRYERS, MICROWAVE OVENS, AND TOASTERS.  
8.4.2 Battery Operating Time  
SEE TABLE IV ON PAGE 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
16  
8.5.3 Troubleshooting Guide:  
TROUBLESHOOTING TIPS  
POSSIBLE CAUSES  
1. Inverter not adequately warmed up.  
RECOMMENDATIONS  
PROBLEM  
Turn inverter switch OFF, then ON again.  
Repeat if necessary.  
LACK OF  
POWER OUTPUT  
2. Source battery voltage below 10-volts.  
3. Equipment being operated draws too  
much power.  
Recharge/replace source battery.  
Reduce load to appropriate maximum for the  
inverter.  
VECTOR Power Force 150 POWER INVERTER  
PRODUCT SPECIFICATIONS  
4. Inverter in thermal shutdown.  
Allow inverter to cool down for at least 15  
mins. before turning ON again.  
Replace fuse (see section in this manual).  
Clean or replace, as necessary, for proper  
MAXIMUM CONTINUOUS POWER . . . . . . . . . . . . . . . . . . . . . 150 WATTS  
SURGE CAPACITY (PEAK POWER) . . . . . . . . . . . . . . . . . . . . . . 300 WATTS  
MAXIMUM EFFICIENCY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90%  
NO LOAD CURRENT DRAW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.06A  
INPUT VOLTAGE RANGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-15 VDC  
LOW VOLTAGE SHUTDOWN ACTIVATION . . . . . . . . . . . . . . . 10.0 VOLTS  
WAVE FORM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOD. SINE WAVE  
# OF AC RECEPTACLES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ONE  
FUSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30 AMP  
WEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.46 LBS (0.66 KG)  
LENGTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3/8 IN. (137 MM)  
WIDTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1/2 IN. (114 MM)  
HEIGHT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 7/16 IN. (37 MM)  
5. Inverter/main fuse blown.  
6. Accessory receptacle in vehicle or  
INDUSTRIAL 900™ is dirty or not working. connection.  
1. Using average quality voltmeter.  
2. Inverter is overloaded.  
Use “true” reading RMS meter.  
Reduce load to appropriate maximum for the  
inverter.  
Keep input voltage above 10.5-volts to  
maintain regulation.  
LOW OUTPUT  
VOLTAGE  
3. Input voltage below 10.5-volts.  
1. High “surge” wattage required for  
start-up.  
Toggle inverters ON/OFF switch ON and OFF  
rapidly several times to generate enough  
power to start the device. If device still does  
not start, the inverter and device are not com-  
patible.  
TV, POWER  
TOOL WILL NOT  
START UP  
2. Vehicle accessory receptacle not  
working.  
Turn vehicle ignition to accessory ON position.  
1. Insufficient power, or excessive  
voltage reduction.  
Check accessory receptacle (cigarette  
lighter socket) and socket connection—  
clean or replace, as necessary for proper  
connection.  
OVERLOAD/  
LOW BATTERY  
LIGHT IS LIT  
2. Battery charge is low.  
Recharge battery.  
3. Battery condition is poor/expired.  
4. Inverter is overloaded.  
Replace battery.  
Reduce load to appropriate maximum for the  
inverter.  
5. Inverter voltage is below 10 amp  
TV picture is poor, or breaks up.  
Recharge/replace battery.  
1. Position the inverter further away from the  
TV, antennae, antennae cables. Use an  
extension cord, if necessary.  
TV INTERFERENCE  
(“SNOW”)  
2. Adjust the orientation of the inverter,  
antennae cables, and TV power cord to  
minimize interference.  
3. Make sure that antenna provides adequate  
signal, and that high quality, shielded  
antennae cable is used.  
4. TV station may be out of range.  
Power supply in some inexpensive audio  
systems does not adequately filter the  
inverters modified sine wave.  
1. Use audio system with higher quality  
internal power supply filtering.  
2. Do not use inverter with inexpensive  
audio systems.  
STATIC, SOUND  
INTERFERENCE  
IN AUDIO SYSTEM  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
19  
1 YEAR LIMITED WARRANTY REGISTRATION FORM  
This Vector Manufacturing, Ltd. product is warranted to the original purchaser only, for one year from the  
date of purchase, to be free of defects in materials and workmanship. In no event will Vector  
Manufacturing, Ltd. be responsible for any amount of damages beyond the retail purchase price of the  
product. All Vector Manufacturing, Ltd. products must be registered within (10) days of purchase. To  
activate this warranty, mail the completed registration form along with a copy of the original sales  
receipt to the address shown below.  
TERMS OF REPAIR OR REPLACEMENT: In the event of a defective unit, return the unit to us within 30  
days of the date of purchase, and we will replace it, free of charge. If returned after 30 days but within  
one year of the purchase date we will repair the unit or, at our option, replace it free of charge. If we  
repair the unit, we may use new or reconditioned replacement parts, at our option. If we elect to replace  
the unit, we may replace it with a new or reconditioned one of the same or comparable design.  
Replacement unit will then be warranted under the terms of our standard one year warranty. The  
customer is responsible for shipping charges on all returned items. During the warranty period, Vector  
Manufacturing, Ltd. will be responsible for the repair or replacement cost plus the return shipping charges.  
LIMITATIONS: Implied warranties, including those of fitness for a particular purpose and merchantability  
(an unwritten warranty that the product is fit for ordinary use), are limited to one year from the  
purchase date. Vector Manufacturing, Ltd. will not reimburse for loss of time, inconvenience, loss of use  
of a product or property damage caused by a product or its failure to work or any other incidental or  
inconsequential damages, including personal injury.  
EXCLUSION: This warranty does not cover bulbs, fuses and batteries, defects resulting from normal wear  
and tear (including chips, scratches, abrasions, discoloration or fading due to usage or exposure to  
sunlight), accidents, damage during shipping to our service facility, alterations, unauthorized use or repair,  
neglect, misuse, abuse, failure to follow instructions for care and maintenance, fire, flood and Acts of  
God. If your problem is not covered by this warranty, call our customer service facility at  
(954) 584-4446 for general repair information and charges. This limited warranty is the only one that  
applies to this product and sets forth all the responsibilities of Vector Manufacturing, Ltd, regarding this  
product. There are no warranties which extend beyond those described herein.  
STATE LAW RIGHTS: Some states do not allow limitations on how long an implied warranty lasts or the  
exclusion or limitation of incidental or consequential damages, so the exclusions or limitations stated  
herein may not apply. This warranty gives the purchaser specific legal rights; other rights, varying from  
state to state, may apply.  
TO REQUEST WARRANTY SERVICE FOR THIS PRODUCT: Within 30 days of the purchase date, return the  
unit, along with the dated sales receipt, to the place of purchase for immediate replacement. After 30  
days, but within the one year warranty period, you may return the product to the address shown below.  
We strongly suggest that you retain the original packaging in case you need to ship the unit. When  
returning a product, include your name, address, phone number, dated sales receipt and a description of  
the reason for return. After repairing or replacing the unit, we will return it to you within four weeks.  
Please activate my Limited Warranty for Model VEC021, VEC021AC  
I have enclosed a copy of the original sales receipt.  
Name___________________________________________________________________  
Street Address ___________________________________________________________  
City_________________________________ State ________ Zip code ______________  
Phone _________________ Fax __________________ E-mail ____________________  
Item Purchased ______________________________Date of Purchase ______________  
Store Where Purchased ___________________________________________________  
UPC Number from package (12 digits)_______________________________________  
All Vector Manufacturing, Ltd. products must be registered within (10) days of  
purchase to activate this warranty. Mail the completed registration form, along with  
a copy of the original sales receipt, to:  
ATTN: CUSTOMER SERVICE / VECTOR MANUFACTURING, LTD.  
4140 S.W. 28th WAY  
FT. LAUDERDALE, FL 33312  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Teac Musical Instrument Gf 680 User Manual
Timex Fitness Electronics 622 095000 NA User Manual
ToCAD Camcorder Accessories CFT P User Manual
Toshiba Speaker System SBX4250 User Manual
Transition Networks Network Router SAPTF33xx 100 User Manual
Tricity Bendix Freezer UF406W User Manual
Tripp Lite TV Cables S065 42I User Manual
Venturer Digital Photo Frame VPF1010DL BLK User Manual
VIPowER Network Card VPA 3528Net User Manual
Vivitar Camcorder F529 User Manual