Uniden Portable Radio UH089sx User Manual

UNIDEN Model uh089sx  
UHF CB Radio  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
Introduction  
The Uniden uh089sx is designed to provide you with years of trouble free service. Its rugged  
components and materials are capable of withstanding harsh environments. Please read this  
Operating Manual carefully to ensure you gain the optimum performance of the unit  
The citizen band radio service is licenced in Australia by ACMA Radio-communications  
(Citizen Band Radio Stations) Class Licence and in New Zealand by MED General  
User Licence for Citizen Band Radio and operation is subject to conditions contained in  
those licenses.  
Features  
=Transmit & Receive FM 40CH (UHF-CB, TX  
Power 5W), Transmission is inhibited at  
CH22 & CH23  
=LCD Display with Backlight  
=Signal Strength Meter  
=RF Power Meter  
=Speaker Audio Volume Level Meter  
=Instant Channel  
=One touch Instant Channel recalling  
=Rotary Channel Select  
=Busy Channel Lock-out Function  
=Roger Beep Function On/Off  
=2 Different CallTones  
=38 Built-in CTCSS (Continuous Tone Coded  
Squelch System) and 104 additional DCS  
(Digital Coded Squelch) codes that are user  
selectable  
=Variable Squelch Level adjust  
=Volume Control with Power On/Off Switch  
=VOX (Voice Activated Function)  
=Duplex Capability (from CH01 - CH08 per  
channel)  
=Group Scan and Priority Channel Watch  
=10 Steps VOX Mic sensitivity adjustment  
=Open Scan  
=Scan Channel Memory On/Off separately  
with Open Scan, Group Scan  
Preventive Maintenance:  
The following system checks should be made every six to twelve months:  
= Check the Standing Wave Ratio (SWR).  
= Inspect the tightness of all electrical connections.  
= Inspect the antenna coaxial cable for wear or breaks on the shielding.  
= Inspect the tightness of all screws and other mounting hardware.  
Troubleshooting:  
Should the unit malfunction or perform poorly, follow these procedures:  
If the transceiver is completely inoperative: Check the power cord and fuse.  
If there is trouble with receiving: Check the VOLUME control setting. Be sure the SQUELCH is  
adjusted properly. Possibly the radio is over-squelched.  
If there is trouble with transmitting: Check that the transmission line (coaxial cable) is securely  
connected to the ANTENNA connector. Check that the antenna is fully extended for proper  
operation. Check that all transmission line (coaxial cable) connections are secure and free of  
corrosion.  
Blackening may occur on the Liquid Crystal Display if the uh089sx has been  
subjected to extreme high temperature (above 60°C) . This is not a fault. Normal LCD  
operation resumes when the temperature stabilizes back to standard operating  
operating condition (0-55°C).  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
Controls/Connectors  
DCS  
MENU  
ENTER  
MON  
DCS/CTCSS  
ANT.  
Controls and Connectors  
Ref Item  
Page Ref Item  
Page  
Liquid Crystal Display (LCD)  
Rotary Channel Selector  
On/Off Volume & Squelch  
Push to Talk (PTT) Switch  
Call Button  
4
6
OS/GS - Open or Group Scan 8,9  
MEM - Memory Scan Channels8,9  
MON - DCS/CTCSS - Monitor and  
6
DCS/CTCSS Tone button  
6,11  
7
DUP - Duplex On/Off  
8
-
7
External Speaker Jack  
Power Input (13.8V DC)  
UHF Antenna Connection  
Instant Button  
11  
10  
8,9  
-
Menu/Enter - Select Button  
SCAN - Scan On/Off  
-
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
Indicators  
DCS  
Indicators  
Ref. Item Page Ref.  
Item Page  
Ref. Item Page Ref.  
MEM - Memory  
- Call Tone  
Item Page  
VOX - Voice Operated  
Microphone  
11  
9
10  
10  
CTCSS -Continuous Tone  
Coded Squelch System  
11  
- Roger Beep  
DCS - Digital Coded Squelch  
System  
BCL - Busy Channel Lockout  
10  
7
11  
11  
7
- Channel number  
INST - Instant Channel  
TX - Transmit  
- DCS/CTCSS Code  
Number  
11  
DUP - Duplex  
8
S/RF- Receive Signal or Transmit  
RF Power Level Meter  
-
-
GS - Group Scan  
SCAN - Scan mode  
MON - Monitor  
9
VOL - Receive Audio Volume  
Level Meter  
8
6
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
Included with your uh089sx  
uh089sx  
io  
el  
Rad  
Mod  
CB  
en  
Unid  
uh089sx Owners Manual  
Microphone Hanger & Screws  
Washers and spare fuse  
Optional Accessories  
Mounting Bracket,  
Mounting Screws, Washer Stars  
And Screws  
DIN Mounting Kit (DMK8990)  
External Speaker (MS100)  
DC Power Cord with fuse  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
Operation  
Setting the Squelch  
Turn the Unit ON by  
rotating the volume control  
clockwise. Turn the outer  
ring of the control to adjust  
the Squelch.  
MENU  
MON  
DCS/CTCSS  
ENTER  
You must select a  
channel which is not in use before setting the  
SQUELCH control. (see below for "Selecting a Channel").  
Think of the squelch  
control as a gate. If you  
turn Squelch fully  
clockwise it raises the  
'Squelch gate' so high that  
no signals get through.  
If you turn the Squelch  
fully counterclockwise it  
lowers the 'Squelch Gate'  
to the extent that all  
signals get through -  
weak, medium and strong  
signals and noise.  
To set the 'Squelch Gate'  
to the desired level, turn  
the squelch knob  
counterclockwise until you  
hear noise. Then carefully  
turn the Squelch knob  
clockwise until the noise  
fades. Now only strong  
signals get through.  
Monitor  
MON  
Press  
signals.  
Press  
to open the squelch and receive all weak  
again momentarily to cancel.  
MON  
MON  
DCS/CTCSS  
Selecting a Channel  
Turn the Rotary Channel Selector to  
select the desired channel.  
For your reference a list of the available  
channels, corresponding frequencies and  
guidelines for their use is printed on page  
12. For Australia, Channels 05 and 35 are  
reserved for Emergency Calls.  
MENU  
ENTER  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
Operation  
Transmitting  
The uh089sx uses the 40 UHF-CB Channels (Channels  
22 and 23 are for telemetry and telecommand  
applications. Transmit is inhibited on these channels).  
Select the desired channel. Press the microphone's PTT  
button and speak normally into the microphone. Hold it  
approx. 7cm from your mouth. Release the PTT button to  
end the transmission and listen for a reply.  
Call Function  
Press the microphone Call Button. A two second ringing tone will be transmitted.  
You may select from 2 types of tones (see p.10).  
Current regulations require calling tones to be restricted to one transmission per  
minute. If a second transmission is attempted within one minute then an error  
tone will sound.  
Using Repeater Channels  
UHF CB repeaters are used to retransmit or relay your signal. Repeaters will extend  
the range of your radio and overcome the shielding effect caused by solid  
obstructions. In normal Simplex operation, your radio transmits on one particular  
frequency and receives on that same frequency. If there is a barrier that partially  
blocks your transmitted signal, the probability of another radio receiving the signal is  
very slim. Hills, tall buildings, metallic structures,...etc tend to act as a screen between  
radios.  
Standard Operation without the aid of a  
Repeater Station.  
Operation with the aid of a Repeater  
Station (Duplex).  
The signal coming from your radio is received by the Repeater Station and the  
re-transmitted at the same time on another channel. This operation is called  
"Duplexing".  
For example,  
CH01 on Duplex Mode will Receive on CH01 but Transmit on CH31  
CH02 on Duplex Mode will Receive on CH02 but Transmit on CH32 etc...  
If you transmit on CH01 Duplex mode, you are actually transmitting on CH31 the  
repeater station down-coverts your signal and retransmits on CH01.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
Operation  
Operating the uh089sx in Duplex Mode  
For this example we are adopting CH01 as the channel being used in your area for  
repeater use.  
Press  
to switch Duplex On.  
If Duplex is not required - press  
again to switch Duplex off.  
Only channels 01 - 08 are  
available for Duplex.  
MON  
DCS/CTCSS  
Check with your local Retailer for  
information on available repeaters.  
Scanning  
The uh089sx has a scanning feature that allows you to search for active channels  
automatically.  
Furthermore, the uh089sx is designed  
to have two types of scanning; Open  
Scanning (OS) and Group Scanning  
(GS), to give you flexibility and allow  
you to use the radio more effectively.  
MON  
Press and Scanning starts.  
The SCAN icon appears.  
DCS/CTCSS  
The scan direction can be changed  
at any time by rotating the channel  
selector left or right.  
Open Scan (OS) Mode  
Allows continuous scanning of all selected channels.  
If an active channel is found, scanning will stop on that channel.  
If the received signal ceases, the unit will wait 3  
seconds for the signal to return, otherwise  
scanning resumes.  
To skip the active channel, press momentarily. Scanning resumes. To deactivate  
SCAN, press or the PTT button on the microphone.  
If SCAN is deactivated while on an active channel, the uh089sx will stay on  
that active channel. If no channels are active, the uh089sx will reinstate the  
starting channel.  
OS Mode is indicated by the absence of the GS icon.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
Operation  
Group Scan (GS) Mode  
Allows you to monitor a Priority (Instant) Channel  
while scanning (Instant Priority channel see p. 11)  
To use GS Mode Scanning, press  
. GS icon appears on the display.  
GS Scanning checks the Instant Priority Channel for activity regularly.  
If the Priority Channel becomes  
active the radio will stay on that  
channel for as long as the signal is  
present. If the received signal  
ceases, Priority Scanning continues  
after 3 seconds.  
If scanning stops on a channel  
which is not a Priority Channel,  
MENU  
MON  
DCS/CTCSS  
ENTER  
uh089sx will continue monitoring  
the Priority Channel for activity  
while listening to the active one.  
To deactivate SCAN, press the  
microphone.  
button or the PTT button on the  
If SCAN is deactivated while it is tuned to an active channel, the uh089sx will  
stay on that active channel.  
If none of the channels are active, the uh089sx will reinstate the scan start  
channel.  
If OS/GS Scanning is initiated when there are no channels programmed in  
OS/GS memory, an error tone will be heard and scanning will not start (see  
Programming Scan Channels - below).  
Programming Scan Channels  
Select which Scanning Mode you  
wish to use - OS or GS.  
Select the channel you want to  
store.  
Press  
to store. MEM icon  
appears and a short tone beep is  
heard.  
To remove the channel from  
MENU  
ENTER  
MON  
DCS/CTCSS  
Memory, press once more.  
The MEM icon disappears.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
Operation  
Selecting the Call tone  
MENU  
Press once. Turn the  
Rotary Channel Selector to either  
MENU  
or . Press and hold for 3  
seconds to store the new setting.  
If a button is not pressed  
within 10 seconds the  
uh089sx will  
MENU  
ENTER  
MON  
DCS/CTCSS  
automatically exit the  
Menu Mode.  
Roger Beep  
A Roger Beep may be added to  
the end of transmission.  
MENU  
Press twice. Turn the  
Channel Selector to display  
.
MENU  
Press and hold for 3  
seconds to store the new setting.  
MENU  
ENTER  
MON  
DCS/CTCSS  
If a button is not pressed  
within 10 seconds the  
uh089sx will  
automatically exit the  
Menu Mode.  
Busy Channel Lockout  
If the channel is already in use,  
you can prevent the uh089sx from  
transmitting . This is particularly  
important when using CTCSS.  
MENU  
Press  
3 times. Turn the  
Rotary Channel Selector  
.
MENU  
ENTER  
MON  
DCS/CTCSS  
to display  
Press and hold  
for 3  
seconds to store the new setting.  
MENU  
If a button is not  
pressed within 10  
seconds the uh089sx  
will automatically exit  
the Menu Mode.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
Operation  
VOX Operation (optional VOX headset required)  
MENU  
Press  
4 times. Turn the  
Rotary Channel Selector to select  
the desired VOX sensitivity (oF, 1-9).  
MENU  
Press and hold  
for 3 seconds  
to store the new setting. Connect  
the VOX headset.  
MENU  
ENTER  
MON  
DCS/CTCSS  
If a button is not pressed  
within 10 seconds the  
uh089sx will automatically exit the Menu Mode.  
INST  
Programming the Instant Priority Channel  
Turn the Rotary Channel Selector to select the Priority  
Channel you prefer.  
Press and hold INST button on the microphone for 3  
seconds to store the new setting. INST icon appears.  
Recalling the Instant Channel  
Momentarily press the INST button on the microphone at any time to return to the  
Instant Channel.  
CTCSS (Continuous Tone  
Coded Squelch System)  
Turn the Rotary Channel Selector  
to the desired channel to use  
MON  
CTCSS. Press and hold  
seconds. CTCSS icon appears.  
for 3  
MENU  
ENTER  
MON  
DCS/CTS  
Turn the Rotary Channel Selector to  
select the desired CTCSS code 01 - 38. Press  
MON  
once to store the  
new setting. To turn off CTCSS (or DCS) select the oF code during setting.  
DCS (Digitally Coded Squelch)  
DCS is a digital extension of CTCSS. It provides 104 extra, digitally coded, squelch  
codes that follow after the 38 CTCSS codes. CTCSS 1-38, followed by DCS 1-99 plus  
DCS 100-104 (represented by o0-o4 on the display).  
Follow the steps for setting a CTCSS code. Turn the Rotary Channel Selector until the  
MON  
DCS codes appear. Press  
to set. The DCS icon and code will display.  
Channels 5 and 35 are used for emergency channels. CTCSS and DCS will  
not operate on these channels.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
UHF CB Channels & Frequencies  
Please follow these guidelines for channel use in Australia:  
Channels 05 and 35 are Emergency Channels.  
Channel 11 is a Calling Channel.  
Channels 22 and 23 are for telemetry and telecommand applications  
and TX is inhibited on these channels.  
General communication is accepted on all other channels with  
these guidelines:  
Channel 40 - road channel (Australia).  
Channels 01-08 (and 31-38) are repeater channels.  
Simplex Mode  
CH No. Transmit / Receive  
Duplex Mode  
Transmit  
Frequency (MHz) Frequency (MHz)  
Simplex Mode  
CH No. Transmit/Receive  
Frequency (Mhz)  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
476.425  
476.450  
476.475  
476.500  
476.525  
476.550  
476.575  
476.600  
476.625  
476.650  
476.675  
476.700  
476.725  
476.750  
476.775  
476.800  
476.825  
476.850  
476.875  
476.900  
477.175 CH31  
477.200 CH32  
477.225 CH33  
477.250 CH34  
477.275 CH35  
477.300 CH36  
477.325 CH37  
477.350 CH38  
21  
22  
23  
24  
25  
26  
27  
28  
29  
30  
31  
32  
33  
34  
35  
36  
37  
38  
39  
40  
476.925  
476.950 (RX only)  
476.975 (RX only)  
477.000  
477.025  
477.050  
477.075  
477.100  
477.125  
477.150  
477.175  
477.200  
477.225  
477.250  
477.275  
477.300  
477.325  
477.350  
477.375  
477.400  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
CTCSS & DCS Code List  
(o0)  
(o1)  
(o2)  
(o3)  
(o4)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
MEMO  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
UNIDEN Model uh089sx UHF CB Radio  
WARRANTY  
UNIDEN UH089SX UHF CB TRANSCEIVER RADIO  
Two Year Limited Warranty  
Note: Please keep your sales docket as it provides evidence of warranty.  
Warrantor: Uniden Australia Pty Limited ABN 58 001 865 498  
Uniden New Zealand Limited  
Warranty only available in original country of purchase  
Elements of Warranty: Uniden warrants to the original retail owner for the duration of  
this warranty, its uh089sx UHF CB Radio (hereinafter referred to as the Product) to be  
free from defects in materials and craftsmanship with only the limitations or exclusions  
set out below.  
Warranty Duration: This warranty to the original retail owner only, shall terminate and  
be of no further effect TWO (2) years after the date of original retail sale. This warranty  
will be deemed invalid if the Product is;  
(A) Damaged or not maintained as reasonable and necessary,  
(B) Modified, altered or used as part of any conversion kits, subassemblies, or any  
configurations not sold by Uniden,  
(C) Improperly installed,  
(D) Repaired by someone other than an authorized Uniden Repair Agent for a defect  
or malfunction covered by this warranty,  
(E) Used in conjunction with any equipment or parts or as part of a system not  
manufactured by Uniden, or  
(F) Where the Serial Number label of the product has been removed or damaged  
beyond recognition.  
Warranty only valid in the country of original retail/sale.  
Parts Covered: This warranty covers for TWO (2) years, the Product and included  
accessories.  
Statement of Remedy: In the event that the Product does not conform to this  
warranty at any time while this warranty is in effect, the warrantor at its discretion, will  
repair the defect or replace the Product and return it to you without charge for parts or  
service. This warranty does not provide for reimbursement or payment of incidental or  
consequential damages.  
This EXPRESS WARRANTY is in addition to and does not in any way affect your  
rights under the TRADE PRACTICES ACT 1974 (Cth) (Australia) or the CONSUMER  
GUARANTEES ACT (New Zealand).  
Procedure for obtaining performance or warranty: In the event that the Product  
does not conform to this warranty, the Product should be shipped or delivered, freight  
UNIDEN AUSTRALIA PTY LTD  
Service Division  
345 Princes Highway,  
Rockdale, NSW 2216  
Fax (02) 9599 3278  
UNIDEN NEW ZEALAND LTD  
Service Division  
150 Harris Road, East Tamaki,  
Auckland  
Fax (09) 274 4253  
prepaid, with evidence of original purchase, (eg. a copy of the sales docket), to the  
warrantor at:  
© 2007 Uniden Australia Pty Limited/Uniden New Zealand Limited  
Printed in China UTZZ01930ZA(0)  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Toro Cable Box 4500 User Manual
Toshiba CRT Television 13A22 User Manual
Toshiba DVD Player SD 3980SU User Manual
Toshiba Flat Panel Television 19SL410U User Manual
Toshiba Projection Television 43HX71 User Manual
Tricity Bendix Oven E 750 User Manual
Tripp Lite Automobile Accessories SR25UBEXPKD User Manual
Velocity Micro Computer Accessories SEAL IT 100 User Manual
Verbatim Computer Hardware K7VT4 4X User Manual
Waves Stereo Equalizer API560 User Manual