Power Related Issues
Important: To prevent memory from being corrupted, do not unplug the AC
adapter during the time the memory is accessed for programming or auto store.
Notes:
• If when you connect the AC adapter the [VOL] /Power Switch is ON, the
scanner may not power on. Should this occur, simply turn the control OFF, then
ON again.
• If the scanner loses power (as when you turn off your car’s ignition with the
scanner’s power switch on), it can lose some system settings such as display
color and backlight. To ensure that such settings persist, either change the
setting using the scanner’s menu or power the scanner off then back on using
the power switch after making such setting changes.When you turn off the
scanner using the power switch, the scanner remembers the last settings and
mode. When you turn power back on, it resumes the previous mode.
Precautions
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Precautions........................................................................................................................................ 2
Power Related Issues ................................................................................................................... 3
Table of Contents ............................................................................................................................. 4
The FCC Wants You To Know ......................................................................................................... 9
Scanning Legally ............................................................................................................................. 9
Introduction .................................................................................................................................... 11
Feature Highlights .......................................................................................................................... 12
General ....................................................................................................................................... 12
GPS ............................................................................................................................................. 15
Weather ....................................................................................................................................... 15
Search ......................................................................................................................................... 15
Auto Store 16
Priority ......................................................................................................................................... 16
PC Control and Cloning 16
Memory Storage Limits .................................................................................................................. 16
Search Lockout Limits ................................................................................................................... 17
About This Manual ......................................................................................................................... 17
Using the Scroll Control [FUNC] ................................................................................................. 17
How the Scanner’s Controls Are Represented in This Manual ................................................... 18
Entering Text Within A Menu Option ........................................................................................... 18
A Short User’s Guide to Assist the First-Time Scanner Enthusiast .......................................... 19
Understanding Scanning and the BCD996T ................................................................................ 21
Understanding the Scanner’s Memory .......................................................................................... 21
Understanding Quick Keys ............................................................................................................ 21
What is Scanning? ......................................................................................................................... 22
What is Searching? ........................................................................................................................ 22
What is CTCSS/DCS? ................................................................................................................... 22
Conventional Scanning .................................................................................................................. 23
Simplex Operation ......................................................................................................................... 23
Repeater Operation ....................................................................................................................... 24
What is Trunk Tracking? ................................................................................................................ 24
Trunked Scanning .......................................................................................................................... 25
Types of Trunking Systems ........................................................................................................... 25
Motorola Trunking ....................................................................................................................... 25
EDACS Trunking ......................................................................................................................... 26
LTR Trunking .............................................................................................................................. 27
Startup Configuration ..................................................................................................................... 28
Setup/Operation .......................................................................................................................... 28
Multi-Site Trunking ......................................................................................................................... 28
I-Call (Motorola/EDACS) ................................................................................................................ 29
Where To Get More Information .................................................................................................... 29
Information On The Internet ........................................................................................................ 29
Included With Your Scanner ......................................................................................................... 30
Setting Up Your Scanner ............................................................................................................... 31
Base Station .................................................................................................................................. 31
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting Up an Audio Recording Device or Computer Recording ................................................... 33
Vehicle Installation ......................................................................................................................... 33
Mounting Using the Bracket ........................................................................................................ 33
Mounting Using the DIN-E Sleeve .............................................................................................. 34
Removing the Scanner from the DIN-E Sleeve ........................................................................... 36
Mounting Using ISO Technique .................................................................................................. 36
Removing the Display Sticker ..................................................................................................... 37
Connecting an Optional Antenna ................................................................................................... 37
Connecting an Earphone/Headphone ........................................................................................... 37
Connecting an Extension Speaker ................................................................................................ 38
Controls, Keys, and Functions ..................................................................................................... 39
A Look At The Display ................................................................................................................... 44
Operation ........................................................................................................................................ 45
Turning On the Scanner and Setting the Squelch ......................................................................... 45
Startup Key Operation ................................................................................................................... 45
Conventional ............................................................................................................................... 45
Trunked ....................................................................................................................................... 45
Search Range ............................................................................................................................. 45
Scanning Systems ......................................................................................................................... 46
Preprogrammed System Tips ........................................................................................................ 47
Selecting Systems to Scan ............................................................................................................ 47
Selecting System Channel Groups ................................................................................................ 47
Locking/Unlocking Systems ........................................................................................................... 48
Locking/Unlocking Channels ......................................................................................................... 48
ID Scan/ID Search Mode ............................................................................................................... 48
Holding On a System ..................................................................................................................... 49
Holding On a Channel ................................................................................................................... 49
Quickly Storing an ID During ID Search ........................................................................................ 49
Quick-Storing Channels or Talk Group ID’s (TGID) ...................................................................... 49
Trunking Activity Indicators ............................................................................................................ 50
Toggling the Display Mode ............................................................................................................ 51
Optimizing P25 Performance ........................................................................................................ 52
Conventional System .................................................................................................................. 52
Trunked System .......................................................................................................................... 52
Using the Menu .............................................................................................................................. 54
Programming General Settings .................................................................................................... 55
Setting and Using the Backlight ..................................................................................................... 55
Setting the Dimmer ..................................................................................................................... 55
Setting the Backlight Color .......................................................................................................... 56
Adjusting the Key Beep ................................................................................................................. 56
Setting the Audio AGC .................................................................................................................. 56
Setting the Display Orientation ...................................................................................................... 57
Adjusting the Display Contrast ...................................................................................................... 57
Setting the GPS Format ................................................................................................................ 57
Setting the Position Format ......................................................................................................... 57
Setting the Time Format .............................................................................................................. 58
Setting the Time Zone ................................................................................................................. 58
Setting the Distance Units ........................................................................................................... 58
Table of Contents
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Serial Port Speed ........................................................................................................ 58
Displaying Scanner Information ..................................................................................................... 59
Viewing Memory Used ................................................................................................................ 59
Viewing the Firmware Version and Electronic Serial Number ..................................................... 59
Initializing the Scanner’s Memory .................................................................................................. 59
Connecting Your Scanner to a Personal Computer ....................................................................... 60
Volume/Squelch with PC Control ................................................................................................ 60
Wired Cloning ................................................................................................................................ 60
Programming Your Scanner .......................................................................................................... 62
System Settings .......................................................................................................................... 63
System Options ........................................................................................................................... 63
Site Settings ................................................................................................................................ 65
Channel Settings ......................................................................................................................... 66
Programming Conventional Systems ............................................................................................ 66
Programming Trunked Radio Systems .......................................................................................... 67
Programming System Settings ...................................................................................................... 67
Editing the System Name ............................................................................................................ 67
Specifying the Correct System Type ........................................................................................... 68
Programming System Options ....................................................................................................68
Programming Sites ........................................................................................................................ 76
Programming Channel Groups ...................................................................................................... 83
Setting Up a Channel Group ....................................................................................................... 83
Editing a Channel Group Name .................................................................................................. 83
Setting the Group Quick Key ....................................................................................................... 84
Editing Channels ......................................................................................................................... 84
Locking Out Channel Groups ...................................................................................................... 84
Deleting Channel Groups ............................................................................................................ 85
Programming Channels ................................................................................................................. 85
Creating a Channel ..................................................................................................................... 85
Editing the Channel Name (Alpha Tag) ...................................................................................... 85
Editing Frequencies .................................................................................................................... 86
Editing the Talk Group ID ............................................................................................................ 86
Setting the Audio Type ................................................................................................................ 87
Selecting CTCSS/DCS Tones .....................................................................................................87
Quick CTCSS/DCS Save ............................................................................................................ 88
Setting Channel Modulation Method ........................................................................................... 88
Setting Channel Attenuation ....................................................................................................... 89
Setting Channel Priority .............................................................................................................. 89
Setting Channel Alert .................................................................................................................. 90
Set Record ..................................................................................................................................... 90
Searching and Storing ................................................................................................................... 93
Service Search .............................................................................................................................. 93
Quick Search ................................................................................................................................. 94
Custom Search .............................................................................................................................. 94
Editing a Custom Search Range ................................................................................................... 95
Search With Scan .......................................................................................................................... 96
Set Delay Time .............................................................................................................................. 98
Set Attenuator ................................................................................................................................ 98
Set Record ..................................................................................................................................... 98
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Assigning a Search Range to a Search Key ................................................................................. 98
Saving a Found Channel (Quick Save) ......................................................................................... 99
Auto Search and Store .................................................................................................................. 99
Selecting a System to use for Storing ......................................................................................... 99
Conventional Search and Store .................................................................................................. 99
Trunked Search and Store ........................................................................................................ 100
Using the Close Call Feature ...................................................................................................... 101
Setting Close Call Options ........................................................................................................... 101
Close Call Hits ............................................................................................................................. 103
Close Call Hits with Scan ............................................................................................................ 103
Search and Close Call Options ................................................................................................... 105
Managing Locked-Out Frequencies .......................................................................................... 105
Unlocking All Frequencies ......................................................................................................... 106
Reviewing Locked-Out Frequencies ......................................................................................... 106
Searching for Subaudible Tones ............................................................................................... 106
Screening Out Broadcast Sources ............................................................................................ 106
Finding Repeater Output Frequencies ...................................................................................... 107
Setting the Maximum Auto Store Value .................................................................................... 108
Setting the Modulation Type .................................................................................................... 108
Setting Attenuation .................................................................................................................... 109
Setting Data Skip ...................................................................................................................... 109
Setting the Delay Time .............................................................................................................. 110
Setting the Search Frequency Step .......................................................................................... 110
Setting Record .......................................................................................................................... 110
Adjust P25 Level ....................................................................................................................... 111
Priority Scan ................................................................................................................................ 111
Using Weather Alert (SAME) ....................................................................................................... 113
Searching For a Weather Broadcast ........................................................................................... 113
Turning Weather Alert On/Off ...................................................................................................... 114
Programming a SAME Group ...................................................................................................... 114
Setting WX Alert Priority .............................................................................................................. 115
Fire Tone-Out ................................................................................................................................ 116
Setting Tone-Out Standby ........................................................................................................... 116
Setting Up Tone-Out .................................................................................................................... 116
Tone-Out Multi-Channel Monitoring ............................................................................................ 118
Set Record ................................................................................................................................... 118
Using the BCD996T with a GPS .................................................................................................. 119
Device Compatibility .................................................................................................................... 119
Connecting Your Scanner to a GPS Device ................................................................................ 119
Initial Scanner/GPS Operation .................................................................................................... 119
Location-Based (GPS) Scanning ................................................................................................. 120
Another Example of Multiple Site Creation .................................................................................. 121
Non-Radio Location Based GPS Features .................................................................................. 121
Setting the Options ...................................................................................................................... 122
For POI Only ............................................................................................................................. 123
For Dangerous Xing, and Dangerous Road Only ........................................................................ 123
Deleting a Location ...................................................................................................................... 124
GPS Display Mode ...................................................................................................................... 125
Table of Contents
7
Download from Www.Somanuals.com. All Manuals Search And Download.
GPS Review Location Mode ........................................................................................................ 126
Care and Maintenance ................................................................................................................. 128
General Use ................................................................................................................................. 128
Location ....................................................................................................................................... 128
Cleaning ....................................................................................................................................... 128
Birdies .......................................................................................................................................... 128
Troubleshooting ........................................................................................................................... 129
Specifications ............................................................................................................................... 132
Reference ...................................................................................................................................... 135
Preset Fleet Maps ....................................................................................................................... 135
User Defined Fleet Maps ............................................................................................................. 137
Type I Programming Information .............................................................................................. 137
Size Code Restrictions ............................................................................................................. 138
Preprogrammed Systems and Lockout Options ....................................................................... 139
Preprogrammed Systems with Quick Keys ............................................................................... 140
CTCSS Frequencies .................................................................................................................... 141
DCS Codes .................................................................................................................................. 141
Index .............................................................................................................................................. 143
One-Year Limited Warranty ......................................................................................................... 150
8
Download from Www.Somanuals.com. All Manuals Search And Download.
The FCC Wants You To Know
This scanner has been tested and found to comply with the limits for a scanning
receiver, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential
installation. This scanner generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
There is no guarantee that interference will not occur in a particular installation. If
this scanner does cause harmful interference to radio or television reception,
which can be determined by turning the scanner on and off, you are encouraged to
try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna
• Increase the separation between the scanner and the receiver
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: 1) This device may not cause harmful interference, and 2)
this device must accept any interference received, including interference that may
cause undesired operation.
Scanning Legally
Your scanner covers frequencies used by many different groups, including police
and fire departments, ambulance services, government agencies, private
companies, amateur radio services, military operations, pager services, and
wireline (telephone and telegraph) service providers. It is legal to listen to almost
every transmission your scanner can receive. However, there are some
transmissions that you should never intentionally listen to. These include:
• Telephone conversations (cellular, cordless, or other private means of
telephone signal transmission)
• Pager transmissions
• Any scrambled or encrypted transmissions
According to the Electronic Communications Privacy Act (ECPA), you are subject
to fines and possible imprisonment for intentionally listening to, using, or divulging
the contents of such a conversation unless you have the consent of a party to the
conversation (unless such activity is otherwise illegal). This scanner has been
designed to prevent the reception of cellular telephone transmissions and the
decoding of scrambled transmissions. This is done to comply with the legal
requirement that scanners be manufactured so they are not easy to modify to pick
The FCC Wants You To Know
9
Download from Www.Somanuals.com. All Manuals Search And Download.
up these transmissions. Do not open your scanner’s case to make any
modifications that could allow it to pick up transmissions that are illegal to monitor.
Modifying or tampering with your scanner’s internal components or using it in a
way other than as described in this manual could invalidate your warranty and void
your FCC authorization to operate it.
In some areas, mobile and/or portable use of this scanner is unlawful or requires a
permit. Check the laws in your area. It is also illegal in many areas (and a bad idea
everywhere) to interfere with the duties of public safety officials by traveling to the
scene of an incident without authorization.
A license is required to use this product in Canada.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
Your BCD996T scanner is a state-of-the-art scanner radio with Trunk Tracker IV™
and automatic scanning capabilities. You can store in the dynamic memory
conventional frequencies such as police, fire/emergency, marine, air, amateur, and
other communications. You can store and scan services that use Trunked Radio
Systems and so much more. You can use the scanner’s Scroll Control to quickly
select channels and frequencies, and you can automatically program channels in a
system using the Auto Store feature. Use your scanner to monitor:
• Analog and digital trunked public safety systems (unencrypted only)
• Police and fire departments (including rescue and paramedics)
• NOAA weather transmissions
• Business/Industrial radio and utilities
• Marine and amateur (ham radio) bands
• Air band
• Railroad
• Military and Civilian Aircraft
Your scanner can monitor the following bands
Frequency (MHz)
Lower Edge Upper Edge Modulation
Step (kHz)
5.0
25.0000
28.0000
29.7000
50.0000
54.0000
72.0000
76.0000
88.0000
108.0000
137.0000
144.0000
148.0000
150.8000
162.0000
174.0000
216.0000
225.0000
380.0000
764.0000
794.0000
27.9950
29.6800
49.9900
53.9800
71.9500
75.9950
87.9500
107.9000
136.9750
143.9875
147.9950
150.7875
161.9950
173.9875
215.9500
224.9800
379.9750
512.0000
775.9875
805.9875
AM
NFM
NFM
NFM
WFM
FM
WFM
FMB
AM
NFM
NFM
NFM
NFM
NFM
WFM
NFM
AM
20.0
10.0
20.0
50.0
5.0
50.0
100.0
25.0
12.5
5.0
12.5
5.0
12.5
50.0
20.0
25.0
12.5
12.5
12.5
NFM
NFM
NFM
Introduction
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Frequency (MHz)
Lower Edge Upper Edge Modulation
Step (kHz)
12.5
12.5
12.5
25.0
806.0000
849.0125
894.0125
1240.0000
823.9875
868.9875
956.0000
1300.0000
NFM
NFM
NFM
NFM
Note: The scanner’s frequency coverage is not continuous and does not include
the cellular telephone or UHF TV bands.
Feature Highlights
General
Close Call™ RF Capture Technology — Instantly detects and tunes to nearby
transmissions with no additional programming. See “Using the Close Call Feature”
on Page 101 for more information.
Close Call Do-Not-Disturb — Checks for Close Call activity in between channel
reception so active channels are not interrupted.
Close Call Temporary Store — Temporarily stores and scans the last 10 Close
Call hits so that you can continue to monitor activity on those frequencies, even
after you are out of Close Call detection range.
Dynamically Allocated Channel Memory — Your scanner’s 6,000 channels are
organized so that it more closely matches how radio systems actually work,
making it easier to program and use your scanner and determine how much
memory you have used and how much you have left.
Preprogrammed Systems — Your scanner is preprogrammed with over 500
agencies covering police, fire, and ambulance operations in the 25 most populated
counties in the US, plus the most popular digital systems. A list of the scanner’s
preprogrammed systems is on Page 140.
100 Quick Keys — You can set the scanner so you can quickly select systems
and groups by using the keypad. This makes it easy to listen to or quickly lock out
those systems or groups you don’t want to scan.
13 Service Searches — Frequencies are preset in separate Public Safety, News,
HAM Radio, Marine, Railroad, Air, CB Radio, FRS/GMRS, Racing, TV Broadcast,
FM Broadcast, Military, Air, and Special searches, to make it easy to search for
specific transmissions.
“Soft” Search Keys — Lets you quickly search specified ranges.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Channel Lockout — You can lock out any system, group, frequency, or channel
while scanning. If you lock out a system or group, any channels belonging to that
system or group are also locked out.
Frequency Lockout — You can lock out up to 500 frequencies (250 permanently
locked out + 250 temporarily locked out). The scanner skips locked-out
frequencies while using the Close Call™ feature or while searching.
CTCSS and DCS Squelch Modes — Prevent interference from stations not using
the tone code you select.
Analog and Digital Audio AGC — Helps automatically balance the volume level
between different radio systems.
Fire Tone-Out Standby — Lets you set the scanner to alert you if a two-tone
sequential page is transmitted. You can set up to 10 settings (transmit frequency,
tone frequencies) then select one for standby monitoring. Up to ten tone-outs on
the same RF setting can be scanned at one time.
Broadcast Screen — Sets the scanner to ignore Close Call™ or search hits on
known broadcast frequencies including common pager frequencies.
Custom Screen — Lets you input up to 10 frequency ranges that the scanner will
ignore during Close Call™ or search operation.
Scan/Search Delay — The scanner pauses at the end of a transmission to wait
for a reply. You can set the delay time for each system you scan, and while
searching and using the Close Call™ feature.
Attenuator — Reduces the input strength of strong signals by about 20 dB.
Repeater Reverse — Automatically switches to the input frequency on a
conventional repeater system.
Channel Alert — Alerts you when there is activity on any channel you specify
using your choice of nine unique alert tones.
Memory Check — Lets you see at a glance how much total memory is left.
Search with Scan Operation — Lets you include selected service searches or
custom search ranges during normal scan operation.
Custom Alerts — For each alert in the scanner (such as channel alert, Close Call
alert, emergency alert), you can select from 9 different tone patterns and also set
the alert volume level independently from the main volume level.
Introduction
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Automatic Channel Step — Accepts frequencies on any valid channel step, even
if it does not fall within the band plan’s default step.
Frequency Step — Lets you select a frequency step (5, 6.25, 7.5, 8.33, 10,
12.5,15, 20, 25, 50 or 100 kHz) for manual mode and search mode.
Text Tagging — You can name each system, group, channel, talk group ID,
custom search range, and SAME group, using up to 16 characters per name.
Data Skip — Allows your scanner to skip unwanted data transmissions and
reduces the affect of birdies.
Duplicate Frequency Alert — Alerts you if you try to enter a duplicate name or
frequency already stored in a system.
Memory Backup — If power is lost or disconnected, the scanner retains the
frequencies you programmed in its memory.
Temporary Lockout — Makes it easy to temporarily lock out a system, channel,
or frequency. The lockout is cleared when you turn power off, then back on so you
don’t have to remember to unlock the channels later.
Startup Configuration — Lets you easily manage multiple configurations for your
scanner.
Single-Handed Function Control Operation — You can tap the Function/Scroll
Control to enable the Function mode. It reverts to normal mode in about 3 seconds
from your last press if no other action occurs.
Record Out Jack — Using the appropriate cable and audio recording device with
signal control, you can record live audio of designated channels.
Display and Keypad Backlight — Makes the display and keypad easy to see in
dim light using two color options and six light levels plus off.
Vehicle Power Connection (Orange Wire) — Lets you connect to your vehicle’s
dimmer circuit to also dim the scanner’s display with the vehicle’s dimmer control.
Trunk Tracker IV™ Operation — Follows unencrypted conversations on analog
Motorola, Motorola Astro 25 (APCO 25), EDACS, EDACS SCAT, and LTR trunked
radio systems, including systems in VHF, UHF, 700 MHz, 800 MHz, and 900 MHz
bands. The scanner can scan both conventional and trunked systems at the same
time.
Multi-Site Trunking — Lets you share system channels across multiple sites to
more efficiently use the scanner’s memory and more easily select sites to monitor.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Control Channel Only Scanning — If the scanner is set to scan a Motorola
system, you can set it so it scans using only control channel data. You do not have
to program voice channel frequencies into memory in this mode as long as all
possible control channels are programmed.
Adaptive Digital Threshold — Automatically sets the digital decode threshold for
APCO 25 systems.
GPS
Location Based Scanning — If you connect a GPS unit to the scanner it can
automatically enable and disable systems based on the Location Information
(longitude, latitude, Range) that you provide.
GPS Non-Radio Based Features — The scanner alerts you to Dangerous
Intersections, Speed Alerts, and Points of Interest that you program into the
scanner.
GPS Display Mode — Lets you display extended GPS information such as
Distance to a POI, Direction to a POI, Time to a POI, Speed, Position, and more.
Weather
Weather Search — Lets your scanner receive your local NOAA weather
transmission.
SAME Weather Alert — Lets your scanner sound an alert when a SAME weather
alert signal is transmitted on a NOAA weather channel. The scanner also displays
the transmitted alert type. This helps you quickly find out about severe weather in
your area and lets you avoid false alarms.
WX Priority — Lets your scanner alert you when a weather alert is transmitted on
a NOAA weather channel.
Search
Service Search — Lets you quickly select and search the scanner’s
preprogrammed frequencies.
Custom Search — Lets you program up to 10 custom search ranges. You can
search any of these ranges simultaneously.
CTCSS/DCS Search — Lets the scanner search for CTCSS or DCS tones or
codes on any channel or during a search. The scanner can identify up to 50
CTCSS tones and 104 DCS codes.
Introduction
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Search — Lets you search from the currently-tuned frequency if you are
searching a conventional system.
Auto Store
Frequency AutoStore — Automatically stores all active frequencies into the
selected conventional system.
Talk Group ID AutoStore — Automatically stores all new talk group ID’s into a
channel group you select.
Priority
Priority Scan — Priority channels let you keep track of activity on your most
important conventional channel(s) while monitoring transmissions on other
channels.
Priority Plus — You can set the scanner so it scans only the priority channels.
PC Control and Cloning
PC Control — You can transfer programming data to and from your scanner and
your personal computer, and control the scanner using a computer. This helps you
find frequencies listed on the Internet and load them into the scanner. Free PC
control and programming software will be available at http://www.uniden.com.
Clone Mode — You can clone all programmed data, including the contents of the
scanner’s memory, menu settings, and other parameters from one BCD996T
scanner to another BCD996T scanner.
Memory Storage Limits
Systems
Sites
Sites per Systems
Groups per System
20
Total Channels
6000
500
1000
256
Channels per Conventional
Systems
Channels per Trunked
Systems
Trunked Frequencies per
Site*
1000
250
750-1000
* depending on the number of TGID in the system.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Search Lockout Limits
Temporary L/O
Frequencies
Permanent L/O
Frequencies
Skipped
Review
Frequencies
500
250
250
Search Mode
Menu Mode
Close Call Mode
About This Manual
The screen displays used in this manual are representations of what might appear
when you use your scanner. Since what you see depends on the frequencies and
user IDs for your area and the settings you select, you might notice some
differences between what is in this manual and what appears on your scanner.
To get the most from this manual, review the contents to become familiar with the
basic functions available. If you are new to scanning or trunk tracking, start with
the following short introduction to scanning and follow-up with the enclosed
reprinted article on Programming provided with the courtesy of Popular
Communications magazine.
Using the Scroll Control [FUNC]
The Scroll Control is a dual purpose control. It also lets you switch to secondary
function operations. When used in this manner, you see Fin this manual. Located
prominently on the right of the BCD996T’s front panel, the knob/switch lets you
easily control channel selection, plus Normal and Function Modes, as well as how
most of the information appears on the display.
To adjust menu settings, change channels in Hold mode, and resume
scanning: Simply turn the Scroll Control.
To use Ftap the Scroll Control. This action is written in shorthand as Fwhich is
fully explained in the next section. When you tap the control f appears and
remains in the upper left corner of the display for 3 seconds. During this time,
press any button to access the button’s second function. Or, press and hold the
Scroll Control for 2 seconds. The scanner beeps, and the function is “latched” so
that is does not return to normal mode until you tap the Scroll Control again. f
flashes at approximately 1 second intervals.
If you select Function while scanning, the BCD996T continues to scan, but holds
on the current system until the function operation is cancelled.
Introduction
17
Download from Www.Somanuals.com. All Manuals Search And Download.
How the Scanner’s Controls Are Represented in This
Manual
To help navigate the scanner’s menus, the steps shown in this manual show the
displays you see and the keys you press or control you operate to get a desired
result. We use a form of shorthand symbols to save space.
The following example shows you how to use the scanner’s menu to edit an
existing system name. It shows you the key to press in brackets [MENU] to select
a menu option and the option you see on the LCD in Boldface Courier type
(Program System) when you press [MENU]. It also instructs you to turn the
Scroll Control (shown as ꢀ) to view a series of choices then press or tap the
Scroll Control (the shorthand action shown as Fto enter a choice such as Edit
Name.
[MENU] ꢁProgram SystemꢁF
ꢀSelect the system ꢁF
Edit NameꢁFThen, edit the system name.
Entering Text Within A Menu Option
To enter a letter, turn the Scroll Control (ꢀ) until the letter, numeral or other
character you want appears. To move the cursor to the left, press [4]. To move the
cursor to the right, press [6].
To clear a character, press [.No] twice. To clear all characters, press [.No] three
times.
To accept an entry, press For press [EYES].
To cancel an entry, press [MENU].
18
Download from Www.Somanuals.com. All Manuals Search And Download.
A Short User’s Guide to Assist the First-Time
Scanner Enthusiast
Welcome to the family of Uniden scanner users. You have just unpacked your
Uniden BCD996T scanner. You are anxious to scan and hear something so you
rotate the [VOL/POWER] control and wait a moment as the opening Message and
Copyright screens confirm the model information. Then, if you live in a residential
area, you probably hear nothing or very little. Why? The reason is simple. The
programmable BCD996T does not instinctively know where you are and what you
wish to listen to.
Take a few minutes to assist in the ‘educating your scanner’ process so you can
enjoy listening for the first time and feel good about your purchase.
Before proceeding, first follow the steps on Page 45 to set the volume and the
squelch levels. Once set correctly, these settings let you listen at a comfortable
level and let the scanner provide a signal whose strength is sufficient to be heard
clearly. Always be sure to connect the provided antenna.
There are several options that quickly assure you that your scanner works.
The easiest is to activate the scanner’s Weather System. Refer to Page 113 for the
steps to tune to the nearest NOAA (National Oceanic and Atmospheric
Administration) broadcast.
Once you establish that the scanner operates using the NOAA information, and if
you live in one of the areas listed on the Preprogrammed charts immediately
following Page 140, you are ready to enter the exciting world of trunk tracking.
Uniden has made it easy for you to start scanning. We have preprogrammed the
BCD996T with more than 500 agencies across the U.S. If you live in one of the
preprogrammed areas, simply press [SCAN/SEARCH] to start scanning. Then,
press [.No] and the two-digit quick key for your area.
One of the preprogrammed systems has common frequencies used across the
country. By default, this system is enabled. To turn this system on or off, press
[.No].
If you do not live in one of the preprogrammed system areas, refer to Page 140.
There, you can follow the steps to select and search among the most popular
service systems.
Finally, you may decide to program the scanner yourself. To correctly program the
BCD996T scanner begin on Page 62. The two programming steps are
1. Plan the system
A Short User’s Guide to Assist the First-Time Scanner Enthusiast
19
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Program the system based on the plan.
Enclosed with the materials provided with your scanner is a reprinted article from
Popular Communications, which, in clear, easy-to-understand language, tells you
how to start the programming session. The article also includes a glossary of
terms and other valuable data. Be sure to take time out to look it over before
proceeding.
To provide you with useful sized worksheets and instructions to complete them, we
have established links at our company website. Visit, http://www.uniden.com/scanners
to see a list of helpful forms. But first, visit http://www.radioreference.com and locate
the system nearest your location that you want to scan. If you register and pay a small
fee, you can download a ready-to-use formatted PDF complete with the data from your
selected system. Otherwise, you can print the blank worksheet on our web page as
you would any other web based page.
The programming data of a large metropolitan area may consist of many pages
depending on how extensive the area’s Public Service System Talkgroups are.
Don’t be overwhelmed. Begin by choosing the Talkgroups of interest to you. Begin
by transferring the data from the Radio Reference website to the worksheets you
obtain from the Uniden website and from there, to the scanner.
You can visit one of the Radio Reference forums and potentially learn of someone
in your immediate area who has programmed the same model scanner in your
area. Then, by using the Clone feature or by exchanging files that you each have
transferred to a computer using the Uniden Advanced Scanner Director (UASD)
software you can install the programmed data into your scanner. Once you have
either programmed or selected the option that lets you start experiencing
scanning, spend the next few minutes learning the basics of trunk tracking for an
even more complete listening appreciation.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Understanding Scanning and the BCD996T
This section provides you with additional background on how scanning works and
how your scanner provides that feature. You don’t really need to know all of this to
use your scanner, but some further background knowledge will help you get the
most from your BCD996T.
Understanding the Scanner’s Memory
Your scanner’s memory is organized in an architecture called Dynamic Allocated
Channel memory. This type of memory is organized differently and more efficiently
than the bank/channel architecture used by traditional scanners. Dynamic
Allocated design matches how radio systems actually work much more closely,
making it easier to program and use your scanner and determine how much
memory you have used and how much you have left.
Instead of being organized into separate banks and channels, your scanner’s
memory is contained in a pool. You simply use as much memory as you need in
the pool to store as many frequencies, and talk group ID’s as desired. No memory
space is wasted, and you can tell at a glance how much memory you have used
and how much remains.
With a traditional scanner, when you program it to track a trunked system, you
must first program the frequencies. Since you can only program one trunking
system per bank in a traditional scanner, if there were (for example) 30
frequencies, the remaining channels in the bank are not used and therefore
wasted. Also, since some trunked systems might have hundreds of talk groups,
you would have had to enter those types of systems into multiple banks in order to
monitor and track all the ID’s.
Understanding Quick Keys
Traditional “Banked” scanners let you select and deselect banks by pressing a
single digit on the keypad. The BCD996T uses a similar method to turn on and off
scanning sites and systems. When you program a system or site, you assign a
quick key (System/Site Quick Key, or SQK) from 0 to 99. You can use the same
quick key for multiple systems, so that the systems are turned on and off together.
To turn a system/site on or off, just press the digit corresponding to the assigned
SQK. For two-digit SQK’s, first press [.No], then enter the two-digit SQK.
The BCD996T lets you assign another quick key to a group of channels within a
system. This group quick key (GQK) can be from 0-9. To turn on and off channel
groups, you press Fwhile the scanner is scanning the system containing the
Understanding Scanning and the BCD996T
21
Download from Www.Somanuals.com. All Manuals Search And Download.
channels, then press the GQK within 2 seconds. Systems can have up to 20
channel groups, and multiple channel groups can be assigned to the same GQK.
What is Scanning?
Unlike standard AM or FM radio stations, most two-way communications do not
transmit continuously. Your BCD996T scans programmed channels until it finds an
active frequency, then stops on that frequency and remains on that channel as
long as the transmission continues. When the transmission ends, the scanning
cycle resumes until the scanner receives another transmission.
What is Searching?
The BCD996T can search each of its 13 service search ranges and up to 10
custom search ranges to find active frequencies. This is different from scanning
because you are searching for frequencies that have not been programmed into
the scanner’s channels. You set the upper and the lower values of the range and
then the scanner searches for any active frequency within the limits you specify.
When the scanner finds an active frequency, it stops on that frequency as long as
the transmission lasts. If you think the frequency is interesting, you can program it
into the scanner’s memory. If not, you can continue to search.
What is CTCSS/DCS?
Your scanner can monitor systems using a Continuous Tone Coded Squelch
System (CTCSS) and Digital Coded Squelch (DCS) system, which allow squelch
to open only when the tone you have programmed with a specific frequency is
received along with a transmission.
CTCSS and DCS are sub-audible tone signaling systems sometimes referred to
as PL or DPL (Motorola’s trademarked terms for Private Line and Digital Private
Line respectively). CTCSS and DCS are used only for FM signals and are usually
associated with both amateur and commercial two-way frequencies. These
systems make use of a special sub-audible tone that accompanies a transmitted
signal.
CTCSS and DCS are used for many purposes. In many cases, CTCSS and DCS
are used to restrict access to a commercial repeater, so that only those units which
transmit the correct tone along with their signal can “talk” to the repeater.
CTCSS and DCS are also used in areas that receive interference where there are
several stations with output frequencies close to each other. When this occurs, you
might hear multiple communications on the same frequency. The stations might
22
Download from Www.Somanuals.com. All Manuals Search And Download.
even interfere with each other to the point where it is impossible to clearly receive
any of the stations. A scanner, such as your BCD996T, equipped with CTCSS and
DCS, can code each received frequency with a specific sub-audible CTCSS or
DCS frequency or code. Then, when you receive multiple signals, you only hear
the transmission with the CTCSS or DCS tone you programmed. If you do not
receive the correct tone with a signal, the scanner’s squelch remains closed and
you hear nothing.
The tables showing the available CTCSS frequencies and DCS codes are found in
the Reference Section of this manual.
Conventional Scanning
Conventional scanning is a relatively simple concept. Each group of users in a
conventional system is assigned a single frequency (for simplex systems) or two
frequencies (for repeater systems). Any time one of them transmits, their
transmission always goes out on the same frequency. Up until the late 1980s, this
was the primary way that radio systems operated.
Even today, there are many 2-way radio users who operate using a conventional
system:
• Aircraft
• Amateur radio
• FRS/GMRS users
• Broadcast AM/FM/TV stations
• Many business radio users
When you want to store a conventional system, all you need to know are the
frequencies they operate on. When you are scanning a conventional system, the
scanner stops very briefly on each channel to see if there is activity. If there isn’t,
the scanner quickly moves to the next channel. If there is, then the scanner pauses
on the transmission until it is over.
Simplex Operation
Simplex systems use a single frequency for both transmit and receive. Most radios
using this type of operation are limited to line-of-sight operation. This type of radio
is frequently used at construction job sites, and with inexpensive consumer radios
such as GMRS/FRS radios. The range is typically 1-15 miles, depending upon the
terrain and many other factors.
Understanding Scanning and the BCD996T
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Repeater Operation
Repeater systems use two frequencies: one transmits from the radio to a central
repeater; the other transmits from the repeater to other radios in the system. With
a repeater-based system, the repeater is located on top of a tall building or on a
radio tower that provides great visibility to the area of operation. When a user
transmits (on an input frequency), the signal is picked up by the repeater and
retransmitted (on an output frequency). The user’s radios always listen for activity
on the output frequency and transmit on the input frequency. Since the repeater is
located very high, there is a very large line of sight.
Typical repeater systems provide coverage out to about a 25-mile radius from the
repeater location.
What is Trunk Tracking?
Your BCD996T is designed to track the following types of trunking systems.
• Motorola Astro 25 (APCO 25) trunking systems.
• Motorola Type I, Type II, Type IIi hybrid, SMARTNET, and PRIVACYPLUS
analog trunking systems, which are extensively used in 800 MHz
communication systems.
• LTR trunking systems
• EDACS SCAT trunking systems
• EDACS trunking systems
When tracking these types of systems, you might want to remember that your
scanner can track more than one trunking system at a time and scan conventional
and trunked systems at the same time.
Conventional scanning is a simple concept. You enter a frequency used by
someone you want to monitor into your scanner’s memory. For example, the police
in your area might transmit on 460.500 MHz, the fire department on 154.445 MHz,
the highway department on 37.900 MHz, etc. So when your scanner stops on a
frequency, you usually know who it is, and more importantly, you can stop on a
channel and listen to an entire conversation. This type of scanning is easy and fun.
However, as the demand for public communications has increased, many public
radio users do not have enough frequencies to meet their needs, creating a
serious problem. Trunking radio systems help solve this problem.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Trunked Scanning
While conventional scanning worked great while there were only a few groups
wanting to use the frequencies, with the advent of smaller, lower-cost radios more
and more agencies and businesses wanted to take advantage of the utility of
2-way radio. As a result, the bands that were used most became full, so new users
were not able to take advantage of the technology as quickly as they wanted.
Trunking solved this frequency shortage by allowing multiple groups to use the
same set of frequencies in a very efficient way. While each type of trunking system
operates a little differently (see the next few sections), they all work on the same
basic premise: even in a system with a lot of users, only a few users are ever
transmitting at any one time.
Instead of being assigned a frequency, as with conventional systems, each group
is assigned a talk group ID. A central computer controls the frequency each group
operates on. This frequency selection is made each time a user transmits. So,
while on a conventional system queries, replies, and follow-ups are all on a single
frequency, they could each be on completely different frequencies on a trunked
system. This semi-random frequency assignment made monitoring such a system
impossible prior to Uniden’s invention of the TrunkTracker scanner.
Not only does your BCD996T scan channels like a conventional scanner, it
actually follows the users of a trunked radio system. Once you know and program
a talk group’s ID (TGID), you won’t miss any of the action.
If you are a new scanner enthusiast, you might want to read the first part of this
manual and use your scanner in conventional mode before you begin trunk
tracking. Understanding scanning fundamentals and terminology will make trunk
tracking much easier. If you are already an experienced scanner operator, you can
review the programming worksheets and their associated pages on the Uniden
website.
Types of Trunking Systems
Trunking systems divide a few frequencies among many different users, but the
way that each system does this is slightly different. This section describes some of
the technical data behind Motorola, EDACS, and LTR trunked radio systems.
Motorola Trunking
While there are different types of Motorola trunking systems, they all use the same
basic trunking method. The system consists of one control channel (or as many as
4 per system but only one is active at any one time), plus one or more voice
Understanding Scanning and the BCD996T
25
Download from Www.Somanuals.com. All Manuals Search And Download.
channels (typically 10, 20, or 28 total channels). When a user presses Push To
Talk (PTT) to transmit, their radio first sends the person’s talk group information to
the control channel. The computer then assigns that talk group to a specific voice
channel and transmits that data over the control channel. All radios in that talk
group switch over to the assigned voice channel and the user can begin speaking.
This all typically takes place in about a second. The person transmitting hears a
beep from their radio when the channel is assigned. Then it is OK to start talking.
The systems in use are:
Motorola Type I — the radios send the radio ID, the fleet and subfleet talk group
ID to the control channel each time they transmit. To program a Type I system, you
need to know the system’s fleet map. The most common fleet maps are included in
the Reference section in this manual. You can also find fleet map resources on the
web such as at http://www.radioreference.com.
Motorola Type II — the radios only send the radio ID and radio channel code to
the control channel. The central computer keeps a database of radio ID’s and
which talk group is assigned to which channel code for each radio, so with this
system the user’s radio sends only about 1/3 the data as a Type I system with each
transmission. Type II systems do not use Fleet-subfleet talk groups; instead they
use a 5-digit ID for each talk group.
Type IIi Hybrid — these systems support a mix of both Type I and Type II users.
Like Type I systems, you must know the system’s fleet map to ensure proper
tracking.
Motorola ASTRO 25 (APCO 25) — these radios are similar to Type II systems,
but send only the radio ID and radio channel code to the control channel,
transmitting voice in digital form.
EDACS Trunking
EDACS trunking works in much the same way as Motorola trunking with a couple
of major differences. In an EDACS system, each frequency used by the system is
assigned a Logical Channel Number (LCN) so that less data needs to be
transmitted by the control channel. Talk groups are assigned in an
Agency-Fleet-Subfleet (AFS) hierarchy.There is one variation of EDACS called
SCAT that your BCD996T can monitor.
Logical Channel Numbers — each frequency used by the system is assigned an
LCN. This information is programmed into each user radio. When a user presses
PTT, their radio sends their AFS information to the control channel. The computer
then assigns that talk group to a channel and sends the LCN so that all other
26
Download from Www.Somanuals.com. All Manuals Search And Download.
radios in that talk group will switch to the correct channel. To program an EDACS
system in your scanner, you will need to know both the frequencies used by the
system and the LCN for each frequency.
Agency-Fleet-Subfleet — talk group ID’s for EDACS systems are assigned in a
way that makes it easy to see at a glance the affiliation of the user. Each radio is
assigned a 2-digit agency identifier from 00 — 15. For example, 01 might be used
by the police, 02 by the ambulance service, 03 by the fire department, and so on.
Each agency is then subdivided up to 16 times to provide fleet identification, and
then 8 more times to identify subfleets.
For example, the complete AFS for the Police Department West District’s dispatch
channel might be 01-062. 01 identifies the agency as the police department, 06
identifies the fleet as the West district, and 2 identifies the subfleet as the dispatch
channel. While these assignments are somewhat arbitrary and vary from system
to system, there are many resources on the web for finding the assignments for
most systems. Because of the logical hierarchy of the AFS system, your BCD996T
lets you assign wildcard ID’s that let you, for example, use only one ID memory to
identify all units in either an agency or a fleet.
EDACS SCAT — (Single Channel Autonomous Trunking) systems operate on a
single channel and alternate control data with analog voice traffic. While your
BCD996T cannot track ID’s in this system, it can eliminate the control data so that
all you hear is the voice transmissions when you monitor this type of system.
LTR Trunking
LTR (Logic Trunked Radio) systems are trunking systems used primarily by
business or private communications service providers, such as taxicabs, delivery
trucks, and repair services. These systems encode all control information as digital
sub audible data that accompanies each transmission, so there is no separate
control channel. Users on an LTR system are assigned to specific talk groups,
which are identified by the radio as six digit numbers.
These numbers are in the form AHHUUU, where:
A = Area code (0 or 1)
H = Home repeater (01 through 20)
U = User ID (000 through 254)
When the scanner receives a transmission on a channel set to the LTR mode, it
first decodes the LTR data included with the transmission. In the ID search mode,
the scanner stops on the transmission and displays the talk group ID on the
display. In the ID scan mode, the scanner only stops on the transmission if the LTR
Understanding Scanning and the BCD996T
27
Download from Www.Somanuals.com. All Manuals Search And Download.
data matches a talk group ID that you have stored in the talk group ID list and have
not locked out. LTR systems are frequently programmed so that each radio has a
unique user ID.
Startup Configuration
Setup/Operation
The Startup Configuration option lets you quickly and automatically lock and
unlock systems based on your desired configuration. Simply hold down a number
button while powering on the scanner or while the opening screens are displayed.
Systems assigned to that number are automatically unlocked and systems
assigned to other numbers are automatically locked. Systems that are not
assigned to any startup configuration are left unchanged.
You could use this feature to give you quick, single-press Quick Key access to
your favorite systems even when you travel to other locations. For example, if you
program your scanner as follows:
System/Site Quick Key
Configuration 1
Fort Worth
Configuration 2
Phoenix
1
2
3
Tarrant County
Arlington
Mesa
Mariposa Cnty
When you are in the Fort Worth area, press [1] while turning on the scanner.
System Quick Keys [1], [2], and [3] then allow you to select between the local
systems. When you travel to the Phoenix area, hold [2] while turning on the
scanner. Now, the Fort Worth systems are locked out and System Quick Keys [1],
[2], and [3] allow selection between the Phoenix-area systems.
Multi-Site Trunking
Some systems covering a very large geographic area use multiple antenna sites
that each operate on different frequencies, but that use the same Talk Group ID’s
for traffic. When programming such a system, you program each site’s frequencies
and other settings into the system, then program the channels into channel groups
within that system. Each site can have its own quick key, so you can turn each
individual site on or off while you scan. Since all sites share all the channels within
the system, multi-site trunking is much more efficient than programming each site
as a separate system.
28
Download from Www.Somanuals.com. All Manuals Search And Download.
I-Call (Motorola/EDACS)
I-calls are direct unit-to-unit transmissions that are not heard by other system
users. Your BCD996T can receive I-call transmissions. See “Setting I-Call
(Motorola and EDACS Systems Only)” on Page 72 for more information about
monitoring I-call transmissions.
Where To Get More Information
By itself, this manual only provides part of what you need to know to have fun
scanning — how to program and use the scanner. Other sources provide
additional information.
Information On The Internet
The Internet is the best source for current frequencies and information about
scanning. Many web sites are dedicated to providing lists of frequencies for your
area. Many have built-in database search engines to assist you.
Make a list of the agencies you want to listen to, then look up the frequencies and
systems used by those agencies. Here are a few useful sites:
• http://www.scannermaster.com * — frequency resources.
You can also call them at 1 800 SCANNER (hours are from 10:00 a.m. to 5:00
p.m. Eastern Time Monday through Friday).
• http://www.radioreference.com * — the Internet’s premier source for
user-supported radio system information.
• http://www.bearcat1.com — frequency information from National
Communications.
• http://svartifoss2.fcc.gov/reports/index.cfm * — conventional frequency
information on file with the US Government
• http://groups.yahoo.com/group/BCD996T * — a group for people interested in
discussing the BCD996T.
* - These web sites are not affiliated with Uniden Corporation.
For more information about Uniden and our products, visit http://www.uniden.com.
Understanding Scanning and the BCD996T
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Included With Your Scanner
Cigarette Lighter
Adapter Power Cord
AC Adapter
(P/N AD-1009)
BCD996T
Scanner
Three Wire DC Power Cord — See Step 5,
“Mounting Using the DIN-E Sleeve” on Page 34
DIN-E Sleeve and
Mounting Bracket
and Hardware
Push-on type
Removal Keys for
Telescopic Antenna
vehicle installation
Remote PC to Scanner
Cable (scanner plug to
Front PC Connecter)
Owner’s Manual and
other printed material
If any of these items are missing or damaged, immediately contact your place of
purchase or Uniden Customer Service at: (800) 297-1023, 8:00 a.m. to 5:00 p.m.,
Central, Monday through Friday.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting Up Your Scanner
These guidelines will help you install and set up your new scanner:
The BCD996T can be placed on a convenient surface in your home as a base
station, and connected to a standard outlet that supplies 120VAC, 60Hz. You must
use either the supplied antenna or an electrically correct outdoor antenna, properly
and safely mounted at your chosen site.
The scanner is also designed to accommodate the DIN-E and ISO-DIN automotive
mounting configurations. A DIN-E sleeve is supplied.
The unit can also be placed above or beneath the dash of your vehicle using the
supplied bracket and mounting hardware.
• If your scanner receives interference or electrical noise, move the scanner or
its antenna away from the source.
• To improve the scanner’s reception, use an optional external antenna
designed for multi-band coverage. (You can purchase this type of antenna at a
local electronics store). If the optional antenna has no cable, use 50-75 Ω
coaxial cable for lead-in. A mating plug might be necessary for the optional
antennas.
• Use an optional mono earphone or mono headset with proper impedance (32
Ω) for private listening. Read the precautions on the inside front cover of this
Owners Manual.
• Do not use the scanner in high-moisture environments such as the kitchen or
bathroom.
• Avoid placing the scanner in direct sunlight or near heating elements or vents.
Base Station
This is the simplest approach to let you get started quickly. Decide on a location
that is convenient to a nearby wall outlet, has desk space to let you complete your
programming worksheets, will safely allow the indoor antenna to be extended, or
near a window to use an outdoor antenna.
Setting Up Your Scanner
31
Download from Www.Somanuals.com. All Manuals Search And Download.
BCD996T
Desk Surface
Bracket
Wood Screws
Mounting Feet (4)
To secure the radio, by means of the mounting bracket, to a surface, follow the
steps below:
1. Attach the four protective rubber feet to the mounting bracket when you
casually use the scanner on a flat surface. Should you desire to permanently
mount the scanner, remove the feet and use wood screws through the bracket
as described in Steps 2 and 3.
2. Use the bracket as a template to mark positions for the two mounting screws.
3. At the marked positions, drill holes slightly smaller than the screws.
4. Remove the paper backing from each washer and stick one inside of each
bracket’s ear, aligning the washer’s hole with the bracket’s hole.
5. Align the bracket with the threaded holes on the sides of the radio case so the
bracket is beneath the radio. Secure the bracket using the two threaded
knobs. Never overtighten the knobs.
Once the radio is positioned, connect it to a source of AC power using the supplied
13.8V, 750 mA AC adapter. Insert the barrel of the AC adapter to the jack on the
rear, upper right side of the radio marked
.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING!
Use only the Uniden-supplied AC adapter with this scanner.
Insert the connector of the supplied indoor telescoping antenna to the BNC
Antenna Connector and apply moderate pressure to secure it.
Setting Up an Audio Recording Device or Computer
Recording
It is best if you plan ahead when you initiate the basic setup of the scanner if you
include the components to record incoming reception. You need only an audio
recording device which can be controlled by a Voice Operated module (VOX)
either externally or from within the unit and the correct connecting cable.
The REC jack on the rear apron provides a constant-level audio output which is
not affected by the setting of the volume control. Use a mono or stereo cable that
ends in a 3.5mm plug for the scanner. The recorder might have its own
requirements as to the proper plug. Check the recorder’s instructions to be sure.
Connect the cable to an external or internal VOX control so that the recorder
activates when audio is present.
You can also connect the cable to the appropriate input jack on your PC so that
with controlling software, you can record to your hard disc.
In order for the function to operate, you must set the channel to record. You must
also set the system’s record option to either All Channel, which will record all
channels regardless of any channel’s setting, or Marked Channel which only lets
recording occur if you have selected record for that channel. Which you choose
will depend on various factors.
Vehicle Installation
You can mount your scanner in your vehicle, using either the supplied bracket or
the supplied DIN-E sleeve.
Mounting Using the Bracket
With the bracket removed from the radio, use the holes in the bracket as a
template to initially mark the location you plan to use in your vehicle. Be absolutely
certain of what might be behind the mounting surface before making any holes, be
it above, or below, or in front of your dash, armrest console, or other location. If you
Setting Up Your Scanner
33
Download from Www.Somanuals.com. All Manuals Search And Download.
drill carelessly, expensive damage can result. If in doubt, consult your vehicle
dealer’s service department or a qualified professional installer.
Important: AVOID AIRBAG DEPLOYMENT ZONES. Ignoring this installation
concern may result in bodily harm and the inability of the airbag to perform
properly.
Mounting
Screws
Star Washers
1. Using appropriate screws or other hardware, secure the bracket.
2. Insert the scanner and insert the bracket knobs to lock the scanner in position.
3. Attach the Cigarette Lighter Power Cord to the rear of the scanner and plug
the adapter end into a dash mounted 12V DC socket.
4. Attach a suitable mounted mobile antenna to the antenna jack on the back of
the scanner.
Mounting Using the DIN-E Sleeve
If you are unsure about how to install your scanner in your vehicle using the DIN-E
sleeve, consult your automobile manufacturer, dealer, or a qualified installer.
Before installing, confirm that your scanner fits in the desired mounting area and
you have all the necessary materials to complete the task. Your scanner requires a
2 x 7-1/8 x 5-5/16 inch (50 x 180 x 135 mm) mounting area. Allow an additional
2-3/8 inch (60 mm) space behind the unit for connectors and wires.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Hole in dash
DIN-E
Sleeve
BCD996T with
outer case removed
1. Remove the bracket if previously attached.
2. Remove the four Philips screws on the rear that secure the outer metal case
and pull off the case with care.
3. Install the DIN sleeve into the opening in your dashboard, lip facing out.
4. Push out the top and bottom tabs to hold the sleeve firmly in place.
5. Before inserting the scanner in the sleeve, attach the cable from the previously
mounted antenna. Attach the DC Power leads. RED goes to a positive (+)
connection on your fuse block while BLACK connects to the vehicle’s chassis
ground (-).
6. Connect the ORANGE lead to one side of the headlamp switch so that when
you activate the headlights, the scanners LCD backlight dimmer level changes
color and intensity. Be sure all the connections are routed away from any
potentially pinching or slicing sheet metal.
7. Slowly slide the scanner into the sleeve until it locks in place.
8. To remove the unit, see “Removing the Scanner from the DIN-E Sleeve” on
Page 36.
Note: if you plan to connect a GPS unit or external speaker at a later time, expect
to remove the unit for ease of making those connections.
Setting Up Your Scanner
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Removing the Scanner from the DIN-E Sleeve
If you plan to connect other devices or wires to the radio, such as a GPS unit, at a
later time, you should plan to remove the scanner from the DIN-E sleeve. This is
easily done using the provided Removal Keys. Refer to the illustration that shows
the removal key(s), on Page 30.
Fully insert both Removal Keys into the slots on the left and the right edges of the
radio’s dress panel. You cannot remove the radio if only one key is available. Press
in fully and the radio will unlock from the sleeve making withdrawal from the sleeve
possible. Store the keys in a safe place for future use.
Removal Keys
Mounting Using ISO Technique
Some vehicles can take advantage of another approach to mounting a radio in a
vehicle, called the ISO technique. However, this technique requires a very detailed
and thorough knowledge of the technique. Therefore, we strongly suggest that if
you have any doubt about your experience and abilities, please consult with a
professional installer who is familiar with the ISO approach to radio installation.
To begin the process, it is first necessary to remove the scanner's outer metal
sleeve from the inner chassis. Unthread the four screws in the rear of the unit.
Slide the cover toward the rear and off. Once the sleeve is removed, you will see
threaded, metric machine screw holes on either side of the chassis cabinet.
Uniden does not supply these screws. Their diameter, length, and screw type
should be chosen by a qualified installer based on the internal vehicle bracket
which will be used in securing the scanner chassis.
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Once the original radio is removed from the vehicle dash and the fit of the scanner
is correct, be sure to connect all the power, audio, antenna, and any other cables
or wires, to the scanner before the scanner is secured.
The following illustration is a typical example of the ISO technique and the general
side mounting screw holes often encountered. It does not actually represent your
vehicle or your vehicle’s mounting bracket. Only a professional installer will be able
to determine the best and correct approach.
Internal Bracket
Dash
Removing the Display Sticker
Before you use the scanner for the first time, remove the protective plastic film
over the display.
Connecting an Optional Antenna
The scanner’s BNC connector makes it easy to connect a variety of optional
antennas, including an external mobile antenna or outdoor base station antenna.
Note: Always use 50- or 75-ohm, RG-58, or RG-8, BNC terminated coaxial cable
to connect an outdoor antenna. If the antenna is over 50 feet from the scanner, use
RG-8 low-loss dielectric coaxial cable. Cable loss increases with higher frequency.
Connecting an Earphone/Headphone
For private listening, you can plug a 1/8-inch (3.5 mm) mini-plug earphone or
headphones (not supplied) into the headphone jack on the front of your scanner.
This automatically disconnects the internal speaker. See “Earphone Warning” at
the front of the manual for important information about using an
earphone/headphone.
Setting Up Your Scanner
37
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING!
Never connect anything other than the recommended amplified extension
speaker to the scanner’s headphone jack. Damage to the scanner might occur.
Connecting an Extension Speaker
In a noisy area, an optional amplified extension speaker, positioned in the right
place, might provide more comfortable listening. Plug the speaker cable’s 1/8-inch
(3.5-mm) mini-plug into your scanner’s back-panel Ext. Sp. Jack.
WARNING!
Never connect any part of the headphone jack to the antenna jack or connect
the radio to an installation where the antenna and audio connection are
grounded. This might also damage the scanner.
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Controls, Keys, and Functions
2
6
5
4
3
11
1
13
7
9
8
10
12
Antenna
DC Adapter
Connector
DC Vehicle
Power In
Record Out
GPS/Remote
External Spkr
The knobs and keys on the BCD996T produce several different actions. You can,
for example, rotate the knobs as well as press them to achieve a different result.
Pressing a key briefly can produce one result while pressing and holding, gives a
different result.
Many controls and keys behave differently depending on the mode your radio is in
when you use them. Carefully examine the following table to separate those
actions.
Note: “Press” means press and release briefly. “Press and hold” means press and
hold down for at least 2-seconds. Fmeans Tap or Press the Scroll Control to
put the scanner into Function mode then press the key under discussion.
Controls, Keys, and Functions
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Control/Key
[Power/VOL]
Label
Mode
Action
Rotate
Result
1
All
All
Power ON — Volume Increase or
decrease
Press
Backlight enabled and intensity changes:
Green Low-Green Medium-Green
High-Red Low-Red Medium-Red High
Function
All
Press F
Sets APCO threshold
then tap VOL
Rotate Scroll
Control
Squelch
2
Rotate
Sets the Squelch Level to permit strong
signals to be heard with no background
noise or lower strength signals with some
background noise
Press
Toggle: Close Call DND-CC Primary-OFF
Turns on Close Call Only Mode
Press & Hold
F + Press Toggles to Tone-Out stand by mode
Scroll Control and
3
All
Rotate
Turn to change scanning or searching
direction.
Function F
Scan or
Custom
Search
Scroll Control Turn to select System or Search Range
+ Rotate
Hold
Rotate
Rotate
Turn to Select channel or frequency
Menu
Turn to scroll to menu item-Tap to select
current option
Press
Use as the <Enter> key for menu choices
Name Edit
Rotate
Turn to select alpha/numeric entry for
names
Monitor
GPS
Rotate
Turn to resume scanning or searching
Turn to operate alphabet skip
F+ Rotate
Press/Tap
Function
Switches to Function Mode; To latch
Func
Function Mode, press and hold
[PRI]
4
Scan
Press
Toggle Priority Mode (On-Plus On-Off)
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Control/Key
[WX]
Label
Mode
Action
Result
5
WX Scan or Press
WX Alert
Toggle between WX Scan and WX Alert
Scan
Scan
Other
Press
Turn to toggle WX Alert Priority On and
Off
Press & Hold
Press
Starts WX Scan
[GPS]
[L/O]
6
7
All
Changes to GPS Mode
Stores current GPS data
Change GPS Display
GPS
Press & Hold
[GPS] + F
Scan
Search
Hold
Press
Temporarily locks out a system channel, a
search frequency, or location data.
Cancelled when Power is turned off.
Press 2X
Permanently locks out system channel, a
search frequency, or location data.
Remains locked after power cycle.
Menu
Press
Exit the menu.
Scan/
Scan Hold
Press & Hold
Enables System Quick Key and Group
Quick Key in the current system.
Unlocks System, Group and Channel in
the current system.
F+ Press &
Hold
Enables all System quick Keys and group
Quick Keys and unlocks all systems,
groups, channels, and search ranges.
Search
Press & Hold
Unlocks all frequencies of Global Lockout
List.
Search Hold
Close Call
Only
Close Call
Hold
Controls, Keys, and Functions
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Control/Key
[0] to [9]
Label
Mode
Scan
Action
Press
Result
8
Enable/Disable selected System/Site
Quick Keys
Custom
Search
Press
Press
Turn on and off each custom search
number
All Hold
Close Call
Tone-Out
Directly enter frequencies or Talk Group
IDs
Scan
F+ Press
Enable/Disable Group Quick Key
Other than
Scan or GPS to [6]
F+ Press [1] [1] to [6] to start check of set search
range
Other than
F+ Press [7] [7/ATT] to toggle attenuator setting
Scan or GPS
All
F+ [0]
Switches to Display Mode- Mode 1 default
Enables Trunking activity Indicators
Scan/Scan
Hold
F+ [.No]
[4] move left
[6] move right
Editing
Name
Press
Moves the cursor left or right during name
or label editing.
[.No]
9
All
Press
Cancel error or warning messages
Enter [.No] For frequency
Hold
Press
Close Call
Only
Press
Enter “-” or “I” for TGID
Tone-Out
Press 2X
Press 3X
Press
Delete current character in name edit
Clear all letters in name edit
Enter “-” or “I” for Direct Entry
Toggle Active Channel Display On or Off
Scan
F+ Press
Scan Hold
Scan
Press
Starts two-digit of (SQK) System/Site
Quick Key
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Control/Key
[EYES]
Label
Mode
MENU
Action
Press
Result
10
Use as the <Enter> key for menu choices
Edit the channel data for active channel
Scan
Press
Scan Hold
Search
Press
Saves the active frequency
Search Hold
Close Call
Close Call
Hold
WX Scan
WX Scan
Hold
Tone-Out
Standby
Press
Switches to Tone Out edit Menu to
change Tone Out Settings
[SCAN/SEARCH] 11
Scan Hold
Press
Press
Start Scanning
Other than
Scan or
Instant switch to Scan Mode
Scan Hold or
GPS
Search Hold F+ Press
Toggle to resume searching
Toggle to scanner LCD
GPS
Press
Trunking
Scan
F+ Press
Toggle ID Search and ID Scan.
[HOLD/RESUME] 12
Scan
Press
Toggles HOLD on or off; In Close Call
mode, error tone sounds if no frequency is
detected.
Search
Close Call
Only
WX Scan
[MENU]
13
Scan
Scan Hold
GPS
F+ Press
Initiates edit menu for current system,
current search range, or current location
data
Menu
All
Press
Press
Back up one level in the menu.
Use with Scroll Control to select menu
settings
Controls, Keys, and Functions
43
Download from Www.Somanuals.com. All Manuals Search And Download.
A Look At The Display
The display has indicators that show the scanner’s current operating status. The
display information helps you understand how your scanner operates.
The LCD screens shown here are only a few of many that you will see while in
different modes. The ones we show here are more common and will assist you to
get started.
㪪㫇㫉㫀㫅㪾㪽㫀㪼㫃㪻㩷㪫㪸㫏㫀
㪙㫉㫆㫅㫏㩷㪜㪤㪪
㪡㪼㫉㫆㫄㪼㩷㪥㫆㫉㫋㪿
㪛㪸㪻㪼㩷㪚㫆㫅㫍㪼㫅㫋㫀㫆㫅㪸㫃
㪚㪪㪠㩷㪦㫇㪼㫉
1. Group Quick Key
2. Site Quick Key
3. Channel Group Name
4. System Name
5. Hold indicator
8. Talk group ID Number
9. Talk group Frequency
10. System Type (M, C, E, L)
11. Modulation Type (Narrowband FM shown)
12. Attenuation enabled
6. Signal Strength indicator
7. Close Call enabled
13. Priority ON
14. CTCSS or DCS Indicator
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Operation
Turning On the Scanner and Setting the Squelch
To turn the scanner on, rotate [VOL] clockwise. Turn the knob to a comfortable
sound level.
Rotate the squelch control [SQ] clockwise until you either hear a broadcast or
noise just stops. The control is now set for strong signals. If you desire to hear a
weaker signal, turn it counter clockwise from that point until you hear background
noise once more.
Startup Key Operation
You can setup a Startup Key Configuration so that the scanner can change the
lockout for each system or each site by pressing an assigned key while you power
up the scanner or an opening screen is displayed. Navigate to Set Startup Key
there are differences in the menu structure for Trunked and Conventional systems.
Conventional
[MENU] ꢁꢀProgram SystemꢁF
Select the conventional system ꢁF
ꢀEdit Sys OptionꢁF
ꢀSet Startup KeyꢁFfor each system.
Trunked
[MENU] ꢁꢀProgram SystemꢁF
Select the trunked system ꢁF
ꢀEdit SiteꢁF
ꢀSelect the site ꢁF
ꢀSet Startup KeyꢁF for each system or site.
Search Range
[MENU] ꢁꢀSearch for…ꢁF
ꢀEdit ServiceꢁF
ꢀSelect a Service RangeꢁF
ꢀSearch with ScanꢁF
ꢀSet Startup KeyꢁF
OR
Operation
45
Download from Www.Somanuals.com. All Manuals Search And Download.
[MENU] ꢁꢀSearch for…ꢁF
ꢀEdit CustomꢁF
ꢀSelect a Custom RangeꢁF
ꢀSearch with ScanꢁF
ꢀSet Startup KeyꢁF
Assign all the systems/sites that you want to scan at the same time to the same
startup key [0] to [9]. You can only assign a site/system to one startup key. To
leave a system unassigned, press [.No].
Scanning Systems
To begin scanning preprogrammed or programmed systems, press
[SCAN/SEARCH]. The BCD996T scans all unlocked systems in all programmed
and activated quick-key groups and any searches unlocked for search with scan.
To enable or disable systems or sites for scanning, press the site/system’s
System/Site Quick Key while scanning.
Notes:
• If no systems are programmed, or all systems are locked out, Nothing to
Scanappears. Program a system or select a system to scan.
• When scanning multiple systems, the BCD996T scans systems according to
the assigned quick key. Systems assigned to quick key 1 are scanned first,
then 2, 3, 4, etc. Systems not assigned to a quick key are scanned last, then
unlocked searches. Within a quick key, systems are scanned in the order they
were assigned.
• Within a system, channels are scanned according to the assigned channel
group, with the same priority as described above for systems.
• The BCD996T scans a system for the duration you set using the System Hold
Time option (see “Setting the System Hold Time” on Page 70). For trunked
systems, the scanner moves to the next system after the hold time expires, the
current transmission ends, and the channel delay expires. Conventional
systems operate similarly, but all unlocked channels are scanned at least one
time regardless of the hold time setting.
• Each search range is searched for the amount of time you set using the “Set
Hold Time” option. See “Setting the System Hold Time” on Page 70 for more
information.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Preprogrammed System Tips
All systems preprogrammed into the scanner are assigned to a Quick Key. See
“Preprogrammed Systems with Quick Keys” on Page 140 for a list of
preprogrammed systems and their Quick Key assignments.
Notes:
• The systems preprogrammed into the scanner are located primarily in major
metropolitan areas.
• You might hear transmissions on frequencies assigned to very distant stations.
This will happen if a local system also uses the same frequency.
• The Nationwide system assigned to SQK 20 is enabled by default.
Selecting Systems to Scan
To select systems to scan, press Scan then press the quick key assigned to the
system or systems you want to scan. For quick keys [0] - [9], press the quick key’s
number. For quick keys 10-99, press [.No] then press the quick key’s 2-digit
number. To stop scanning the system(s), press [.No] (if the quick key is a 2-digit
quick key) then the number button or buttons again.
The Sx: (system) indicators on the display show the systems that are currently
selected.
Func
To select or lock out a system that is not assigned to a key, press
then rotate
the Scroll Control until the desired system is selected. Then, press [L/O] within 2
seconds to either lock out or unlock the system.
Selecting System Channel Groups
Within a system, you can assign groups of channels to a group quick key (see
“Setting the Group Quick Key” on Page 84).
Follow these steps to activate or deactivate a channel group within a system while
scanning.
1. Tap Fthen turn the Scroll Control to switch to the Function Mode. Then ꢀ
to select the system that has the channel group ypu want to enable or disable.
2. While fstill appears on the display, press the number key corresponding to
the channel group you want to activate or deactivate.
Operation
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Locking/Unlocking Systems
Follow these steps to lock out a system so that it does not scan even if its quick
key is selected.
1. Tap Fto switch to the Function Mode then rotate the control to select the
desired system.
2. Press [L/O] to temporarily lock out the system. Temporary L/Oappears. Or,
quickly press [L/O] twice to permanently lockout the system. Locked Out
appears.
3. To unlock temporarily locked out systems, turn power off and then back on. To
unlock permanently locked out systems, repeat Steps 1 and 2. System
Unlockedappears.
Locking/Unlocking Channels
If the scanner has stopped on a channel press [L/O] once to temporarily lock it out
or quickly press [L/O] twice to permanently lock it out. Cycling power off/on
automatically unlocks temporarily locked-out channels.
To lockout a channel when the scanner has not stopped on the channel, or to
unlock a permanently locked-out channel.
1. Press [HOLD/RESUME] to hold on a channel.
2. Tap Fto switch to the Function Mode , then rotate the control ꢀto select the
system where the channel is stored.
3. Tap For wait 2 seconds, then rotate the Scroll Control ꢀto select the
channel you want to lock or unlock.
4. Press [L/O] to temporarily lock or unlock the current the channel. Double-tap
L/O to permanently lockout the current channel.
ID Scan/ID Search Mode
While you are scanning a trunked system, the scanner can be in either ID Scan or
ID Search mode:
• ID Scan — the scanner only stops on talk group ID’s (TGID) that you have
programmed into the system that are unlocked.
• ID Search — the scanner stops on any unlocked talk group that becomes
active.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
To toggle between ID Scan and ID Search, press Fthen press [SCAN/SEARCH]
while the scanner is scanning the system.
If the scanner does not scan the system long enough for you to easily do this,
press Fand rotate the Scroll Control to select the changed system. Then, press
[SCAN/SEARCH] within 2 seconds.
Holding On a System
To temporarily hold on a system, tap F. To hold on a different system, tap Fthen
rotate the control to select the system. Normal scanning resumes 2 seconds after
your last selection.
To permanently hold on a site or system, press and hold the Scroll Control for 2
seconds. fflashes in the display’s upper left corner. The scanner continues to
scan only the current system. To hold on a different site or system, rotate the
Scroll Control ꢀto select the new site or system then press [EYES].
Holding On a Channel
To hold on a channel, press [HOLD/RESUME] while the channel is active. To
select a different channel, turn the Scroll Control. If you scroll past the beginning
or end of the current system, the scanner selects channels in the previous or next
system. To resume scanning, press [SCAN/SEARCH].
Quickly Storing an ID During ID Search
To quickly store an active talk group ID during ID search, press [EYES]. You see:
Quick TGID Save?
To save the ID into a channel, press [EYES]. Otherwise, press [.No]. If you press
[EYES], the scanner stores the ID into a channel group called Qck Save Grpin
the current system.
Quick-Storing Channels or Talk Group ID’s (TGID)
1. Hold on an existing channel in any system.
2. Enter the frequency or talk group ID you want to store (press twice to enter
hyphens in talk group ID’s).
3. To quick-store the channel or talk group ID, press [EYES].
Otherwise, press [.No].
Operation
49
Download from Www.Somanuals.com. All Manuals Search And Download.
If you enter a frequency then press [EYES], the scanner stores it in the Qck Save
Grpgroup in a system called Qck Save Cnv Sys. These groups are created if
they do not exist. Then, the scanner prompts you to save other channel settings.
If you enter a talk group ID then press [EYES], the scanner stores it into a channel
group named Qck Save Grpin the current system. If the talk group ID’s format is
not the type used by the current system, the scanner displays an error message
and does not save the talk group ID.
If you pressed [.No] in Step 3, the scanner prompts you to select the system and
the group where you want to store the frequency or talk group ID.
Note: The scanner will warn you if you try to store two channels in the same
system that have the same frequency or Talk Group ID or if you try to store two
systems with the same name.
Trunking Activity Indicators
To get a visual indication of the activity on trunking systems, press
[HOLD/RESUME] to hold on any channel. Then tap Fand then press [.No] The
scanner replaces the third line on the display with trunking activity indicators.
When the scanner is monitoring on EDACS or Motorola system, the activity
indicators will show which system frequencies have activity.
Note: For Motorola systems you must program all system frequencies (control and
voice frequencies) for this feature to work.
Trunking Activity Indicators.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
Toggling the Display Mode
To change the display so the channel and frequency or Talk Group ID appear
instead of extended channel information, hold on any channel then press F+ [0].
The scanner displays Display Mode 2. To return to Mode 1, press F+ [0]
Mode1 indicates the channel data under the Channel Name.
Mode2 indicates the frequencies under the Channel Name for Conventional
systems or the TGID number for Trunked systems.
㪛㪸㪻㪼㩷㪚㫆㫌㫅㫋㫐
㪚㪪㪠㩷㪦㫇㪼㫉
㪛㪸㪻㪼㩷㪚㫆㫌㫅㫋㫐
㪚㪪㪠㩷㪦㫇㪼㫉
Channel Name Display Mode 1
Channel Name Display Mode 2
Operation
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Optimizing P25 Performance
You can optimize the scanner’s performance with digital APCO 25 systems. Follow
these steps for each system where you can hear APCO 25 traffic.
Notes:
These steps work only when you can clearly receive the system. If you are in a
weak-signal area or receive interference, these steps will not work. These steps do
not compensate for weak signals or signals subject to interference.
If you set an incorrect decode threshold level in Step 5, the scanner might stop
decoding all digital signals in the system. If this happens, change the setting to a
value between 8 and 12 then repeat these steps.
Conventional System
[MENU] ꢁProgram SystemꢁF
ꢀSelect the system ꢁF
ꢀEdit Sys OptionꢁF
ꢀAdjust P25 LevelF
Trunked System
[MENU] ꢁProgram SystemꢁF
ꢀSelect the system ꢁF
ꢀEdit SiteꢁF
ꢀSelect the site ꢁF
ꢀAdjust P25 Level ꢁF
Make sure the system’s P25 Level option is set to Auto.
Press [HOLD/RESUME] on an active digital channel on the system. HOLDappears
on the display.
Press Fthen [VOL]. fdisappears and APCO threshold Adjust Mode
appears at the bottom of the display.
This number shows the current threshold setting.
㪭㪸㫅㩷㪚㫆㫉㫋㩷㪧㪸㫋㫉㫆㫃
Threshold voltage levels.
*In Manual mode or Auto mode, if you rotate the
knob clockwise, the threshold level is adjusted
wider than default level. If you rotate the knob
counterclockwise, the level is adjusted narrower.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
• The next to last line on the display now shows the digital error rate and the
AUTO decode threshold start level (0-20).
• The last line on the display shows the decode threshold levels for the system.
Allow the scanner to monitor channel activity for several minutes. The error rate
should drop for each transmission and the threshold levels should automatically
adjust to a more optimal setting. Then, once the threshold level settles to a stable
setting, write down these values. This is the system’s optimum decode threshold.
Rotate the Scroll Control ꢀto set the AUTO decode threshold start level to a
setting that most closely matches the system’s optimum decode threshold. Now,
when the scanner stops on a system, it will use this threshold as the starting point
for automatic optimization.
To exit when the settings are complete, press Fthen press [VOL].
Optimizing P25 Performance
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Menu
The BCD996T incorporates an effective menu system that lets you make all the
necessary setting options required to program the scanner and effectively use the
many features. To use the menu, press [MENU].
You immediately see the screen display the menu title at the top and three of ten
menu options beneath. Using the Multifunction Scroll Control, you can rotate the
control left or right to quickly review all ten listings.
The depth of each menu selection is extensive. For the purpose of this manual, the
following chart indicates the primary menu selection, the purpose of that selection,
and a reference to the page or pages that provide the details associated with the
option.
Menu Item
Let’s You…
For Detail, See…
Program System
Select options related to setting up See "Scanner Programming"
a new system or editing one
already programmed.
reprint.
Program Location
Srch/CloCall Opt
Choose GPS related locations for
data to alert, confirm location, and
provide you with an audible
warning if desired.
Lets you adjust settings that affect See “Search and Close Call
the scanner during search and
Close Call operation
Options” on Page 100
Search for...
Close Call
Set Priority
Choose and search programmed
ranges of desired services
See “Searching and Storing” on
Page 93
Setup the radio to receive, and let See “Using the Close Call Feature”
you hear, nearby strong stations.
on Page 101
Lets you scan a conventional
system and check for designated
priority channels.
See “Priority Scan” on Page 111
WX Operation
Tone-Out for...
Wired Clone
Settings
Set choices for weather scanning. See “Using Weather Alert (SAME)”
on Page 113
Select up to 10 Tone-Out settings See “Fire Tone-Out” on Page 116
or Standby
Copy data directly from one
See “Wired Cloning” on Page 60
BCD996T to another BCD996T.
Choose settings for miscellaneous See the respective pages for each
but convenient options. option:
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming General Settings
This section covers your scanners general settings.
Setting and Using the Backlight
The LCD has a backlight that can be set to green or red with three levels of
intensity for each color plus OFF.
To make your selection, press [VOL]. Each time you press the control, the
backlight cycles in the following order.
OFF — Low Intensity Green — Medium Intensity Green — High Intensity Green —
Low Intensity Red — Medium Intensity Red — High Intensity Red
When you stop at the desired level, the scanner remembers your setting the next
time you turn on the scanner.
You can also set the backlight using the menu.
Setting the Dimmer
If you connect the orange wire to a wire in your car that changes state when you
turn on the headlights, the scanner can automatically dim the display when you
turn on the headlights.
Tapping [VOL] overrides the menu setting and cycles through all backlight
settings.
[MENU] ꢁꢀSettingsꢁF
ꢀSet BacklightꢁF
ꢀSet DimmerꢁF
Auto— Use this setting if you have connected the scanner to your vehicle’s
headlights using the orange wire. If you have connected the wire, the scanner
automatically dims the backlight when you turn on the headlights. After selecting
this option, select either:
+ Polarity— If the headlight wire is connected to +12V when the headlights
are on.
- Polarity— If the headlight wire is connected to vehicle ground when the
headlights are on.
Programming General Settings
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Manual— Use this setting to manually set the dimmer level to High, Middle,
Low, or Off. To guide you in your selection, at each setting the display shows
what you can expect to see.
Setting the Backlight Color
[MENU] ꢁꢀSettingsꢁF
ꢀSet BacklightꢁF
ꢀSet ColorꢁF
Set this option to either Red or Green.
Adjusting the Key Beep
[MENU] ꢁꢀSettingsꢁF
ꢀAdjust Key BeepꢁF
Auto— the scanner automatically sets the key beep to match the master volume
setting level you select.
Level 1- 15— the scanner lets you manually select one of fifteen key beep
levels. As you turn the Scroll Control, the beep gets louder. Press Fwhen you
reach the desired level.
Off— the scanner turns the key beep off.
Setting the Audio AGC
[MENU] ꢁꢀSettingsꢁF
ꢀSetAudio AGCꢁF
This setting helps balance the audio level you hear as you listen to different radio
sources so you can hear them at a similar volume. Use this setting if you listen to
an audio source that has natural changes in audio level for which you want to
compensate.
You can set the Analog or the Digital mode to be on or off.
Analogꢀto select either on or off specifically for receiving analog channels.
On— Press Fto select.
Off— Press Fto select.
FFDigitalꢀto select either Onor Offspecifically for receiving digital channels.
On— Press Fto select.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Off— Press Fto select.
Setting the Display Orientation
[MENU] ꢁꢀSettingsꢁF
ꢀSet Upside-downꢁF
This setting controls the orientation of the display. If you set Upside-down to On,
the scanner inverts the display text and graphics.
Adjusting the Display Contrast
There are 15 contrast levels. As you scroll from level 1 to 15 you see the contrast
change. Press the Scroll Control to lock the desired level until the time you desire
to change it.
[MENU] ꢁꢀSettingsꢁF
Adjust ContrastꢁF
ꢀSelect a level Level 1 to Level 15ꢁF
Setting the GPS Format
[MENU] ꢁꢀSettingsꢁF
ꢀSet GPS Format F
These settings control how the scanner handles GPS input when you are using the
location-based functions.
Setting the Position Format
[MENU] ꢁꢀSettingsꢁF
ꢀSet GPS FormatꢁF
ꢀSet Pos FormatꢁF
This setting controls the format used for entering GPS coordinates into the
scanner.
DMS: DDD° MM’ SS.ss — Enter the location in Degree, Minute, Second format.
DEG: DDD.dddddd — Enter the location in Degree and fraction format.
Programming General Settings
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Time Format
[MENU] ꢁꢀSettingsꢁF
ꢀSet GPS FormatꢁF
ꢀSet Time FormatꢁF
This setting controls the format used for displaying the time on the GPS data
screens.
12H— the scanner displays time in 12-hour format using am for mornings and pm
for evening times.
24H— the scanner displays time in 24-hour format using 0 for midnight and 23 for
11 pm.
Setting the Time Zone
[MENU] ꢁꢀSettingsꢁF
ꢀSet GPS FormatꢁF
ꢀSet Time ZoneꢁF
This setting controls the format used for adjusting Universal time to local time. Set
your local time’s offset from UTC (formally known as GMT).
Setting the Distance Units
[MENU] ꢁꢀSettingsꢁF
ꢀSet GPS FormatꢁF
ꢀSet Pos UnitꢁF
This setting controls the distance units shown in the GPS data screens and used
for entering distance for POI’s
mile— The scanner uses miles.
km— The scanner uses kilometers.
Setting the Serial Port Speed
[MENU] ꢁꢀSettingsꢁF
ꢀSetSerial PortꢁF
ꢀSetBaud RateꢁF
ꢀSet Front Portor Set Rear PortꢁF
Use this setting to control the data rate used for the front and back panel serial
ports. You typically set the front port to match the speed used to communicate with
58
Download from Www.Somanuals.com. All Manuals Search And Download.
your PC (default 115200 bps) and the back port to the speed used to communicate
with an attached GPS (default 4800 bps). Note that the back port is male. You may
need a gender changer and a null modem adapter to use a typical DB9 serial
cable from the rear port.
For Serial Port Speed (Baud Rate), select from
4800 bps
9600 bps
19200 bps
38400 bps
57600 bps
115200 bps
OFF
Displaying Scanner Information
Viewing Memory Used
[MENU] ꢁꢀSettingsꢁF
ꢀSee Scanner InfoꢁF
ꢀ% Memory UsedꢁF
The scanner displays the percent of memory that is used and the number and the
percent of systems, sites and channels that are created.
Press any key to return to the previous menu, then press any key to exit the menu.
Viewing the Firmware Version and Electronic Serial
Number
[MENU] ꢁꢀSettingsꢁF
ꢀSee Scanner InfoꢁF
ꢀFirmware VersionꢁF
Press any key to return to the previous menu, then press any key.
Initializing the Scanner’s Memory
Warning: This clears data you have entered. You cannot restore user
programmed data that has been deleted. You can, at a last step, restore only the
original factory data.
1. To initialize the scanner’s memory, turn off the scanner.
Programming General Settings
59
Download from Www.Somanuals.com. All Manuals Search And Download.
2. While pressing [2], [9], and [HOLD] at the same time, turn on power.
At that point anything you have programmed is gone.
You are given a last opportunity to keep the factory programmed data when you
see the question:
Restore Preprogram List?Yes=”E”/”No= ”.”
If you do not say Yes, the scanner is totally empty.
Connecting Your Scanner to a Personal Computer
You can connect your scanner, by means of the
supplied cable, to a personal computer to download
data from the computer to the memory of the scanner.
Before you proceed, you must first set the scanner’s
communications speed as described in the previous
section. In addition you will need a copy of Uniden
Advanced Scanner Director software. You can
download the software from http://www.uniden.com in
the Customer Service Downloads link.
Important: Start with a high baud rate setting. If, during transfer, you get an error
message, reduce the setting and start again until you get reliable, complete
transfer of data.
Volume/Squelch with PC Control
If you use a PC to control the scanner, and you change the scanner’s volume or
squelch setting using the PC, the scanner ignores the front-panel control’s current
setting. However, if you later change the volume or squelch setting using the
front-panel control, the scanner uses the control’s setting (i.e. the scanner pays
attention to the last method used).
Wired Cloning
Using the scanner in a cloning setup lets you transfer programmed data directly
from a source or master BCD996T to a target or slave BCD996T. Wired cloning
between other models to the BCD996T is not possible.
[MENU] ꢁꢀWired CloneFꢀMasteror Slave(select one as the master
and one as the slave)
60
Download from Www.Somanuals.com. All Manuals Search And Download.
To clone (transfer) data directly from one BCD996T scanner to another BCD996T
scanner, you must first connect the scanners to each other using the included
connection cables and a DB9 null modem adapter and for the rear port, a DB9
gender changer (neither included), available at most computer stores. Then you
must set one scanner as the source and the other as the target.
Connected as
shown, and with
both ports
correctly selected,
no other hardware
is needed.
1. Select the Front Port for the Master. Select the Rear Port for the Slave or vice
versa.
2. Plug the 9-pin serial connector into the unit designated as the Rear Port.
3. Plug the smaller connector into the front port of the unit designated as Front
Port.
4. When you are ready to clone the scanner, press [SCAN/SEARCH] on the
slave scanner first, then [SCAN/SEARCH] on the master scanner. The
master scanner checks the connection between the two scanners, then
transfers its data to the slave scanner.
5. When the transfer is complete, Completeappears on both scanners. If the
transfer did not work, Errorappears on the master scanner. Readjust the
baud rate to a lower setting and try again.
Programming General Settings
61
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Your Scanner
Your BCD996T comes preprogrammed with over 500 state and local agencies,
both analog and digital, selected from the most populous areas in the US. This
should let you get started quickly to enjoy your new scanner. However, to get the
most enjoyment from your scanner (especially if you do not live near one of these
counties), you must customize the programming for your area.
To edit an existing system, use the menu to navigate to the system setting you
want to change. This section assumes you are programming a new system.
Programming radio systems is completed in two major steps. Don’t skip either
step!
1. Plan the system.
2. Program the system into your scanner according to the plan you prepared in
Step 1.
To make this easier, planning worksheets are available as a download for each
system type from the Uniden America Corporation website [www.uniden.com].
General Notes
You can store up to 6000 channels in up to 500 systems.
Each trunking system can have up to 256 sites and up to 250 trunked channels
(TGID). Each conventional system can have up to 1000 channels.
Your scanner can have up to a total of 1000 sites. Each system can have up to 20
channel groups.
The following table provides you the information to successfully perform various
steps connected with programming each of the systems: Conventional, Motorola,
EDACS, and LTR. Some operations are common to all of the systems while some
are specific to a given system. Use the following table to quickly locate the step
you want or need to perform (where required), the reference page for that step,
and to which system or systems it applies.
62
Download from Www.Somanuals.com. All Manuals Search And Download.
System Settings
MOTOROLA
EDACS
System
CNV
See
Pages
LTR
P25 /
Wide
Settings
TYPE I
SCAT
TYPE II
/Narrow
Edit Name
P. 67
P. 68
•
•
•
•
•
•
•
•
•
•
•
Edit Sys
Option
•
Edit Site
P. 76
P. 83
P. 76
P. 76
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Edit Group
•
Copy System
•
•
•
Delete
System
•
System Options
MOTOROLA
EDACS
System Option
CNV
See
Pages
LTR
P25/
WIDE/
NARROW
Settings
TYPE I
SCAT
TYPE II
Set Quick Key
P. 68
P. 69
P. 69
P. 70
P. 70
P. 70
P. 70
P. 71
P. 71
P. 72
P. 72
•
Set Startup Key
•
Set Lockout
•
Set Hold Time
•
ID Scan/Search
•
•
•
•
•
•
•
•
Set Delay Time
•
•
Set Data Skip
•
Set LocationInfo
•
Edit Fleet Map
Set Status Bit
Set End Code
•
•
•
•
•
Programming Your Scanner
63
Download from Www.Somanuals.com. All Manuals Search And Download.
MOTOROLA
EDACS
WIDE/
System Option
Settings
See
Pages
CNV
LTR
P25/
TYPE I
SCAT
TYPE II
NARROW
Set I-Call
P. 72
P. 73
•
•
•
•
•
•
Emergency
Alert
EDCS ID
Format
P. 73
•
Set Record
P. 74
P. 74
•
•
•
•
•
•
•
•
•
•
•
Rvw ID:Srch
L/O
Clr All L/O IDs
P. 74
P. 75
•
•
•
•
Adjust P25
Level
64
Download from Www.Somanuals.com. All Manuals Search And Download.
Site Settings
MOTOROLA
TYPE I
MOTOROLA P25/TYPE II
EDACS
L
T
R
Site Setting
800MHz
800MHz
Splinter
800MHz 800MHz 900MHz
VHF
UHF
P25
WIDE NARROW SCAT
Standard
Standard Splinter
Band
Band Band
Edit Name
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Set Quick Key
• •
• •
Set Startup
Key
Set
Frequencies
•
•
•
•
•
•
•
•
•
•
• •
Set Modulation
Set Attenuator
Set Lockout
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
• •
• •
• •
•
•
•
•
•
•
Set Hold Time
Edit Band Plan
Set C-Ch Only
•
•
•
•
•
•
•
•
•
•
Set
LocationInfo
•
•
•
•
• •
•
Adjust P25
Level
•
•
•
•
•
•
•
•
Delete Site
New Site
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Programming Your Scanner
65
Download from Www.Somanuals.com. All Manuals Search And Download.
Channel Settings
Channel Setting
CNV
MOT TYPE I
MOT TYPE II/P25
EDACS
LTR
Edit Name
•
•
•
•
•
•
Edit Frequency
Edit TGID
•
•
•
•
•
•
•
•
Set Audio Type
Set Modulation
Set Attenuator
Set Priority
•
•
•
•
•
•
•
•
•
•
Set Alert
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Set Record
Set Lockout
Copy Channel
Delete Channel
New Channel
Programming Conventional Systems
[MENU] ꢁProgram SystemꢁF
ꢀNew SystemꢁF
ꢀConventionalꢁF
Confirm? Yes=”E” / No=”.”
The scanner creates an empty conventional system with a default name of
System n C. Note that “n” is a number that increments as you add new systems.
The Con the right side of the display indicates that this is a conventional system.
After creating the system:
1. Set system-level settings that apply to conventional systems in “Programming
System Settings.”
2. Create one or more channel groups with channels as described in
“Programming Channel Groups.”
66
Download from Www.Somanuals.com. All Manuals Search And Download.
Programming Trunked Radio Systems
[MENU] ꢁProgram SystemꢁF
ꢀNew SystemꢁF
Then, select the system type:
MOT TYPE 1— Motorola Type I systems
MOT TYPE 2/P25— Motorola Type II and APCO 25 systems
EDCS WIDE/NARROW— EDACS Wide and Narrow systems
EDCS SCAT— EDACS SCAT systems
LT— LTR Systems
The scanner creates an empty system with a default name of System nx.Note
that “n” is a number that increments as you add new systems. The “x” on the right
side of the display is M for Motorola system, E for EDACS systems, and L for LTR
systems. After creating the system:
1. Set the system-level settings in “Programming System Settings” that apply to
the type of system you selected.
2. Set up at least one site for the system as described in “Programming Sites” on
“Programming Sites” on Page 76.
3. To scan specific channels, create one or more channel groups with channels
as described in “Programming Channel Groups.”
Programming System Settings
Throughout the following sections, you will notice a heading on the right, such as
MECL in the next section. This helps designate the system types to which the
section applies. In this section, the instructions apply to M (Motorola), E (EDACS
Wide/Narrow), C (Conventional), and L (LTR).
Editing the System Name
MECL
Each system name can be up to 16 characters. Abbreviate as necessary to fit. For
Motorola and EDACS Wide/Narrow systems, the system name only appears in the
scanner menu’s Program System listings. It is not shown during scanning. For
other systems, the system name alternates with the Channel group when the
scanner stops on a channel.
The default system names include the following letter in the 16th position to
indicate the system type: M= Motorola; E= EDACS; L= LTR; C= Conventional;
Programming Your Scanner
67
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifying the Correct System Type
In order for trunk tracking to work properly, you have to specify the correct system
type when you create the system. Here are some tips for selecting the correct
type:
• Use online resources, such as the www.radioreference.com database, to
identify the system type.
• Even though a system has digital channels, it is not necessarily a P25 system.
To be P25, the system type must be described as Project 25 (there are many
Motorola 800 Standard systems that have some digital channels.
These should be entered as Motorola 800 Standard and not P25).
• EDACS Wide is the same as EDAC Standard.
• EDACS Networked sites are EDACS Narrow
Following these steps to change the system name.
[MENU] ꢁProgram SystemꢁF
ꢀSelect the system ꢁF
ꢀEdit NameꢁF
To enter a letter, turn the Scroll Control until the character you want appears. To
enter a decimal point, press [.No]. To move the cursor to the left, press [4]. To
move the cursor to the right, press [6].
To clear a character, press [.No] twice. To clear all characters, press [.No] 3 times.
To accept an entry, press [EYES] or F.
Programming System Options
MELC
Editing the System Quick Key
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect a conventional system ꢁF
ꢀEdit Sys OptionꢁF
ꢀSet Quick KeyꢁF
After selecting this option, select any number from 0-99 to assign the system to a
quick key or press [.No] to assign the system to no quick key, then press F.
68
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes:
• Access single-digit system/site Quick Keys by pressing the single digit on the
keypad during scanning. Access two-digit system Quick Keys by pressing
[.No] then both digits.
• You can assign as many systems to the same quick key as you want.
• To be scanned, a system’s Quick Key must be activated and the system must
be unlocked.
Setting the Startup Key
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect a conventional system ꢁF
ꢀEdit Sys OptionꢁF
ꢀSet Startup KeyꢁF
Select a startup key from 0-9 or select [.No] for no startup key.
Notes:
• To unlock the system at startup, press and hold the selected startup key while
you apply power. If you do not press the startup key at the time you turn on
power, you can still act while the opening screens are displayed.
• The system Quick Key is also enabled.
• If you press a different key at startup, the system is locked out.
• If you do not assign the system a startup key, the system is not affected by any
key press during startup.
Setting the System Lockout
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect a conventional system ꢁF
ꢀEdit Sys OptionꢁF
ꢀSet LockoutꢁF
Unlocked— The system is scanned when its quick key is enabled.
Temporary L/O— The system is not scanned, even if its quick key is enabled.
Cycling power removes the lockout.
Lockout— The system is not scanned, even if its quick key is enabled. You must
manually unlock the system.
Programming Your Scanner
69
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the System Hold Time
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect a conventional system ꢁF
ꢀEdit Sys OptionꢁF
ꢀSet Hold TimeꢁF
Set how long the scanner will remain scanning on this system before moving to the
next system (up to 255 seconds). Note that the scanner will scan all unlocked
channels at least one time, regardless of the system hold time setting.
Setting ID Scan/ID Search
MEL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit Sys OptionꢁF
ꢀID Scan/SearchꢁF
Sets whether the scanner only stops on talk groups you have programmed in (ID
Scan) or whether the scanner stops on any unlocked channel (ID Search).
Setting Channel Delay Time
MELCS
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit Sys OptionꢁF
ꢀSet Delay TimeꢁF
This setting controls how many seconds the scanner waits after a transmission
ends before resuming scanning. Enter a value from [1] to [5] or Off,
then press F.
Notes:
• The default setting is 2 seconds for each system.
• This setting applies to all channels within the system.
Setting Data Skip
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect a Conventional system ꢁF
ꢀEdit Sys OptionꢁF
ꢀSet Data SkipꢁF
70
Download from Www.Somanuals.com. All Manuals Search And Download.
This setting controls whether the scanner automatically skips channels it identifies
as data. This includes channels with either no audio or a constant-level audio
source. If turned on, the scanner resumes scanning as soon as it detects the data
signal.
Setting Location Information
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect a Conventional system ꢁF
ꢀEdit Sys OptionꢁF
ꢀSet LocationInfoꢁF
This setting control whether the system is automatically enabled and disabled
when you connect a GPS to the scanner.
Set Latitude — Enter the system’s latitude using the format you selected in the
system settings.
Set Longitude — Enter the system’s longitude using the format you selected in the
system settings.
Set Range — Set the system’s range using the units you selected in the system
settings.
Set GPS Enable — L/O status is automatically controlled by receiving data from
GPS.
Setting the Fleet Map
M (Type I Only)
[MENU] ꢁProgram SystemꢁF
ꢀSelect a Motorola Type I system ꢁF
ꢀEdit Sys OptionꢁF
ꢀEdit Fleet MapꢁF
Preset— select from the16 most common fleet maps
Custom— allows you to enter a custom fleet map. Enter the size code (0 to 14)
for each block. Press Fto select.
For Motorola Type I and Type IIi Hybrid systems, you must enter a system fleet
map in order for the scanner to properly track and display talk group ID’s. The fleet
map is usually included in the same resource that provided system frequencies
and talk group ID lists.
Note: If you don’t know the fleet map for your Motorola Type I system, check the
Internet such as www.radioreference.com or the other websites we reference.
Programming Your Scanner
71
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Status Bit
M
[MENU] ꢁProgram SystemꢁF
ꢀSelect a Motorola Type I or II system ꢁF
ꢀEdit Sys Option ꢁF
ꢀSet Status Bit ꢁF
Ignore— the scanner rounds all received ID’s down to the next interval of 16.
The default setting is Ignore.
Yes— the scanner treats all received ID’s as unique ID’s.
Note: Motorola analog systems use talk group ID’s in multiples of 16. ID numbers
that fall between these ID’s indicate special status flags for the system. This setting
determines how the scanner will handle ID’s that are not multiples of 16.
Select your setting then press F.
Setting End Code Operation
M
[MENU] ꢁProgram SystemꢁF
ꢀSelect a Motorola Type I or II system ꢁF
ꢀEdit Sys OptionꢁF
ꢀSet End CodeꢁF
This setting determines how the scanner handles the transmission end code sent
by most Motorola systems. Select your setting then press F.
Yes— the scanner immediately returns to the control channel when it detects the
end code.
Ignore— the scanner does not return to the control channel until the carrier
drops.
Note: The default setting is Yes.
Setting I-Call Operation
ME
[MENU] ꢁProgram SystemꢁF
ꢀSelect a Motorola Type I, II or EDACS Wide/Narrow system ꢁF
ꢀEdit Sys OptionꢁF
ꢀSet I-Call ꢁF
This setting determines how your scanner treats I-calls while ID Searching.
On— the scanner tracks I-calls.
72
Download from Www.Somanuals.com. All Manuals Search And Download.
Off— the scanner ignores I-calls. The default setting is Off.
Only— the scanner only tracks I-calls and ignores other radio traffic on the
system. Press Fto select.
Note: To set the I-Call to a wildcard receive condition, press [.No] + [0].
Setting the Emergency Alert Option
ME
[MENU] ꢁProgram SystemꢁF
ꢀSelect a Motorola Type I, II or EDACS Wide/Narrow system ꢁF
ꢀEdit Sys OptionꢁF
ꢀEmergency AlertꢁF
Off— the scanner does not alert you to emergency transmissions.
Alert 1- 9— the scanner sounds an alert beep to notify you of the emergency
transmission. The default alert is Off. You can choose any of 9 different beep
types. Once you choose an alert tone, next:
ꢀꢁSet Level ꢁF
Auto— the scanner automatically sets the emergency alert beep to the master
volume level.
Level 1- 15— the scanner adjusts the volume you hear to the level you select.
Setting the EDACS ID Format
E
[MENU] ꢁProgram SystemꢁF
ꢀSelect an EDACS Wide/Narrow system ꢁF
ꢀEdit Sys Option ꢁF
ꢀEDCS ID Format ꢁF
EDACS Talk Group ID’s are commonly provided in one of two formats: AFS and
Decimal. This setting determines how you enter EDACS ID’s and how the scanner
displays them.
AFS Format— the scanner uses AFS format for Talk Group ID’s
Decimal Format— the scanner uses decimal format for Talk Group ID’s
Note: The scanner defaults to AFS (agency, fleet, subfleet) format - the format
used in most EDACS systems.
Programming Your Scanner
73
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the System Record Option
MELCS
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit Sys Option ꢁF
ꢀSet Record ꢁF
This setting controls how the scanner handles the record option for channels in the
system.
All Channel— The scanner sends the audio for all channels in the system to
the REC jack, regardless of the channel’s record option setting.
Marked Channel— The scanner only sends the audio for channels that have
the Record option turned on to the REC jack.
Off— The scanner does not send any audio from any channel in the system to
the REC jack, even if the record option is turned on for a channel.
Note: In order for the function to work, you must set the channel to record. You
must also set the system’s record option to either All Channel(which will record
all channels regardless of the channel’s record setting) or Marked Channel
(which only records the channels you’ve set to record).
Reviewing ID Search Lockouts
MEL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit Sys Option ꢁF
ꢀRvw ID:Srch L/O ꢁF
The scanner displays each ID you have locked out in ID Search mode and gives
you the option to unlock the ID. To unlock an ID, rotate the scroll to select the
locked out ID, then press [EYES]. If no ID’s are locked out, the scanner displays
“Nothing Locked / Press Any Key.”
Clearing All Locked Out ID’s
MEL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit Sys Option ꢁF
ꢀClr All L/O IDs ꢁF
To quickly unlock all IDs in the system, answer “Y” to “Confirm? Unlock All (Y/N).”
74
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjust the P25 Decode Threshold
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect a conventional system ꢁF
ꢀEdit Sys Option ꢁF
ꢀAdjust P25 Level ꢁF
This setting determines some system-specific parameters for digital channels. In
most cases, setting this to Autoprovides the best performance. However, you can
also manually set the digital decode threshold. This setting affects all channels in
the current system. See “Optimizing P25 Performance” on Page 52.
Auto— the scanner automatically adjusts the digital decode threshold to match
the transmission you are hearing when it receives a strong signal and has a high
decode rate.
Manual— lets you manually adjust the digital decode threshold. To manually
adjust the P25 level, select Manual.
Default— sets the digital decode threshold to the default value. Use this setting
to return to the value that usually provides adequate performance. This is handy
as you have manually adjusted the value to a setting that prevents proper
decoding.
Note: This setting has no effect on how these systems are received.
Editing Sites
MESL
Use this option to enter and edit site information for the current system. See
“Programming Sites” on Page 76 for instructions for each site option. Note that you
must program at least one site for each trunked system in order for your scanner to
scan the system.
Editing Channel Groups
MECL
Use this option to enter and edit channel groups and channel information. See
“Programming Channel Groups” for instructions for each channel group and
channel option. Note that you must program at least one channel group and one
channel for each conventional system in your scanner. You do not have to enter
channel group information for trunked systems, but doing so makes it easier to
follow specific talk groups.
Programming Your Scanner
75
Download from Www.Somanuals.com. All Manuals Search And Download.
Copying Systems
MECSL
Occasionally you might want to copy and rename a system to highlight one group
over another.
One system might be called City - Fire and the same system City - PD with
adjustments to data within.
This lets you quickly locate the desired set of data.
To copy a system including all settings, groups, and channels:
[MENU] ꢁProgram SystemꢁF
ꢀSelect the existing system ꢁF
ꢀCopy SystemꢁF
New Sys Name?
Enter your new name using the Scroll Control and [4] and [6] to traverse the
display and enter characters. Press Fwhen finished.
Deleting Systems
MECSL
[MENU] ꢁProgram SystemꢁF
ꢀSelect the existing system ꢁF
ꢀDelete SystemꢁF
Confirm Delete?
Yes=”E” / No= ”.”
Important: Deleted systems cannot be restored. You must re-enter them.
Programming Sites
MESL
This section covers settings that apply to trunked radio site. You must program at
least one site for each trunked radio system. When you program multiple sites, all
sites share the same channel groups and channels within the system.
Note: You can only program one site in an EDACS SCAT and LTR system.
Setting the Site Name
ME
Each site name can be up to 16 characters. Abbreviate as necessary to fit. The
site name alternates with the Channel group when the scanner stops on a
channel.
The default site names include the following letter in the 16th position to indicate
the system type:
76
Download from Www.Somanuals.com. All Manuals Search And Download.
MS1: Motorola 800 MHz Type I Standard
MS2: Motorola 800 MHz Type II Standard
MP1: Motorola 800 MHz Type I Splinter
MP2: Motorola 800 MHz Type II Splinter
P25: APCO 25 (all bands)
M92: Motorola 900 MHz
MV2: Motorola VHF
MU2: Motorola UHF
EDW: EDACS Wide
EDN: EDACS Narrow
Follow these steps to change the system name.
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked systemꢁF
ꢀEdit SiteꢁF
ꢀSelect a Site ꢁF
ꢀEdit NameꢁF
To enter a letter, turn the Scroll Control until the character you want appears. To
enter a decimal point, press [.No]. To move the cursor to the left, press [4]. To
move the cursor to the right, press [6].
To clear a character, press [.No] twice. To clear all characters, press [.No] 3 times.
To accept an entry, press [EYES] or F.
Setting the Site Quick Key
MESL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked systemꢁF
ꢀEdit SiteꢁF
ꢀSelect a Site ꢁF
ꢀSet Quick KeyꢁF
After selecting this option, select any number from 0-99 to assign the system to a
quick key or press [.No] to assign the system to no quick key, then press F.
Programming Your Scanner
77
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes:
• Access single-digit system/site Quick Keys by pressing the single digit on the
keypad during scanning. Access two-digit system Quick Keys by pressing
[.No] then both digits.
• You can assign as many systems to the same quick key as you want.
• To be scanned, a system/site’s Quick Key must be activated and the system
must be unlocked.
Setting the Site Startup Key
MESL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked systemꢁF
ꢀEdit SiteꢁF
ꢀSelect a Site ꢁF
ꢀSet Startup KeyꢁF
Select a startup key from [0] to [9] or select [.No] for no startup key.
Notes:
• To unlock the system at startup, press and hold the selected startup key while
you turn on the scanner.
• The system/site’s Quick Key is enabled when it is unlocked.
• If you press a different key at startup, the system is locked out.
• If you do not assign the system a startup key, the system is not affected by any
key press during startup.
Setting Site Frequencies
MESL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked systemꢁF
ꢀEdit SiteꢁF
ꢀSelect the site ꢁF
ꢀSet FrequenciesꢁF
ꢀNew Frequency(or select an existing frequency) ꢁF
Input a system frequency using the number keys and [.No] key, then press F. If
you are entering frequencies for an LTR or EDACS system, the scanner also
prompts you to enter the LCN for the frequency you just entered. Obtain LCN’s
(logical channel numbers) from the same source as the other system information.
To enter additional frequencies, press [MENU], then ꢀto select New
Frequency.Then repeat the above.
78
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: If you select Control Channel Only mode (see “Setting Control-Channel
Only (Motorola Systems Only)” on Page 81), you only need to enter the
frequency(s) that can be assigned as the control channel. Most frequency lists
usually indicate which of the frequencies are the control channel frequencies.
Otherwise, you must enter all of the frequencies.
Setting Site Modulation
ML
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit SiteꢁF
ꢀSelect a Site ꢁF
ꢀSet ModulationꢁF
Auto— the scanner uses the default modulation for the frequency band.
FM— the scanner uses FM (frequency modulation) for the frequency band.
NFM— the scanner uses narrowband FM for the frequency band.
Note: The default setting is Auto.
This setting controls the modulation method used for the frequency band. In most
cases, if you leave this set to Auto, the scanner automatically selects the correct
modulation type for the system you are programming.
Setting Site Attenuation
MESL
Enable Attenuation if you are near strong signal sources. Attenuation can help
reduce interference and desensitization that strong signals create. You can also
turn this setting on or off by holding on a trunked system, then pressing F+ [7].
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit SiteꢁF
ꢀSelect a Site ꢁF
ꢀSet AttenuatorꢁF
Off— the attenuator is off.
On— site frequencies are attenuated by about 20 dB.
Setting Site Lockout
MESL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
Programming Your Scanner
79
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀEdit SiteꢁF
ꢀSelect a site ꢁF
ꢀSet LockoutꢁF
ꢀSelect from the following choices then press F
Unlocked— the system is scanned when its quick key is enabled.
Temporary L/O— the system is locked for this session.
Lockout— the system is not scanned.
Setting Site Hold Time
MESL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit SiteꢁF
ꢀSelect a site ꢁF
ꢀSet Hold TimeꢁF
This setting controls how many seconds the scanner looks at a site before moving
to the next unlocked site or system. Using the number keypad, enter a value from
0-255, then press Fto save the setting.
Notes:
• If the scanner cannot detect a control channel on an EDACS or Motorola
system, it immediately moves to the next site or system. The scanner always
scans LTR or SCAT systems for at least 1 second to check for current activity.
• If you select 0 and the control channel is received, the scanner stays on the
system for a minimal time (only long enough to check current system activity).
• The default setting is 2 seconds for each system.
• The scanner moves to the next system after the hold time expires, any current
transmission ends, and the channel delay time expires.
Editing the Band Plan
M (VHF and UHF only)
In order for the scanner to scan Motorola VHF and UHF sites, you must enter
parameters that allow the scanner to determine the frequencies in use by the
system. This information is normally available at the same source where the other
system information is found.
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit SiteꢁF
80
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀSelect a site ꢁF
ꢀEdit Band PlanꢁF
You can enter up to 3 band plans. Select the plan to enter or edit, then follow the
prompts to enter the Base Frequency, Channel Step, and Channel Offset for the
site.
Setting P25 Band Plans
(P25 Only)
The BCD996T includes two operation modes for P25 systems: explicit mode and
implicit mode channel assignment. Explicit mode systems include all information
needed to determine voice frequencies on the control channel. You must supply
the system’s band plan for implicit systems for the scanner to correctly determine
voice frequencies.
To set the band plan for a P25 system:
[MENU] ꢁProgram SystemꢁF
ꢀEdit SiteꢁF
ꢀEdit Band PlanꢁF
Then, follow these steps:
1. ꢀthe Band Plan table entry you want to edit and ꢁF.
2. Enter the base frequency for the table entry and ꢁF.
3. Enter the spacing for the table entry (in kHz) and ꢁF.
Repeat 1-3 for additional table entries.
Notes:
• For Explicit mode systems, leave all entries blank.
• There is no way to determine the correct entries using the scanner (other than
trial and error). You must get this information from another source. Uniden
America Corporation does not have this information.
Setting Control-Channel Only Mode
M (except for P25)
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit Site (current)ꢁF
ꢀSelect a non-P25 site ꢁF
ꢀSet C-Ch OnlyꢁF
Programming Your Scanner
81
Download from Www.Somanuals.com. All Manuals Search And Download.
This setting determines the frequencies you need to enter for Motorola systems.
Select your setting, then press F.
On— You only need to enter control channel frequencies.
Off— You must enter all voice and control channel frequencies.
Note: The scanner defaults to On.
Setting Site Location Information
MESL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit Site (current)ꢁF
ꢀSelect a site ꢁF
ꢀSet LocationInfoꢁF
This setting control whether the system is automatically enabled and disabled
when you connect a GPS to the scanner.
Set Latitude— Enter the system’s latitude using the format you selected in the
system settings.
Set Longitude— Enter the system’s longitude using the format you selected in
the system settings.
Set Range— Set the system’s range using the units you selected in the system
settings.
Set GPS Enable— Depending on the data received from the GPS, the L/O
status of the site is automatically controlled.
Adjust P25 Level
MEL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit Site (current)ꢁF
ꢀSelect a site ꢁF
ꢀAdjust P25 Level ꢁF
This setting determines some site-specific parameters for digital channels. In most
cases, setting this to Autoprovides the best performance. However, you can also
manually set the digital decode threshold. This setting affects all channels in the
current site. See “Optimizing P25 Performance” on Page 52.
82
Download from Www.Somanuals.com. All Manuals Search And Download.
Auto— the scanner automatically adjusts the digital decode threshold to match
the transmission you are hearing when it receives a strong signal and has a high
decode rate.
Manual— lets you manually adjust the digital decode threshold. To manually
adjust the P25 level, select Manual.
Default— sets the digital decode threshold to the default value. Use this setting
to return to the value that usually provides adequate performance. This is handy is
you have manually adjusted the value to a setting that prevents proper decoding.
Note: This setting has no effect on how these sites are received.
Deleting Sites
ME
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit SiteꢁF
ꢀSelect a site ꢁF
ꢀDelete SiteꢁF
Confirm Delete?
Yes=”E” / No= ”.”
Important: Deleted sites cannot be restored. You must re-enter them.
Programming Channel Groups
MECL
Setting Up a Channel Group
MECL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit Group ꢁF
ꢀNew Group F
The scanner creates a group with a default name of Group n.nincrements by
one for each new group you create within a system.
Editing a Channel Group Name
MECL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit GroupꢁF
ꢀSelect a Group ꢁF
ꢀEdit NameꢁF
Programming Your Scanner
83
Download from Www.Somanuals.com. All Manuals Search And Download.
Follow these steps to enter/edit the group name.
1. The current name displays with the first character of the name highlighted.
2. Rotate the Scroll Control to select a new first letter. Press [6] to move one
character to the right. Repeat the Scroll Control action to change the
character. To move one character to the left, press [4].
3. Repeat Step 2 until you have entered the system name. Then press Fto
accept the setting.
Notes:
• Each group name can be up to 16 characters. Abbreviate as necessary to fit.
• The group and system (for conventional, SCAT, and LTR systems) or site (for
Motorola and EDACS systems) name alternate in the top line of the display
when the scanner stops on a channel.
• Press [.No] twice to delete the current character.
• Press [.No] three times to clear the entire alpha tag.
Setting the Group Quick Key
To assign a Quick Key to a Group, follow these steps.
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit GroupꢁF
ꢀSelect the Group ꢁF
ꢀSet Quick KeyꢁF
Select a desired quick key for this Group.
Editing Channels
MECL
Once you create a channel group, store channels in that group. See “Programming
Channels” on Page 85 for specific channel options.
Locking Out Channel Groups
MECL
[MENU] ꢁProgram SystemꢁF
ꢀSelect an existing system ꢁF
ꢀEdit GroupꢁF
ꢀSelect an existing group ꢁF
ꢀSet LockoutꢁF
84
Download from Www.Somanuals.com. All Manuals Search And Download.
This setting determines whether the scanner will scan this group of channels.
Select your setting, then press F.
Lockout— the group is not scanned.
Temporary L/O— the group is not scanned for this session. The L/O is
cancelled when you cycle power.
Unlocked— the group is scanned. The default setting is Unlocked.
Deleting Channel Groups
MECL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit GroupꢁF
ꢀSelect a channel group ꢁF
ꢀDelete GroupꢁF
Confirm Delete?
Yes=”E” / No= ”.”
Important: Deleted channel groups cannot be restored. You must re-enter them.
Programming Channels
MECL
Creating a Channel
MECL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit GroupꢁF
ꢀSelect a channel group ꢁF
ꢀEdit Channel ꢁF
Select an existing channel to edit or “New Channel” to create a new channel.
When you create a new channel you are prompted to enter the frequency (for
conventional systems) or Talk Group ID (for Trunked systems). Enter the
information for the channel, then press Fto proceed to setting additional channel
options.
Editing the Channel Name (Alpha Tag)
MECL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit GroupꢁF
ꢀSelect the channel group ꢁF
ꢀEdit ChannelꢁF
Programming Your Scanner
85
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀSelect the channel ꢁF
ꢀEdit NameꢁF
Follow these steps to enter/edit the channel name.
1. The current name displays with the first character of the name highlighted.
2. Rotate the Scroll Control to select a new first letter.
3. Press [6] to move one character to the right.
4. Repeat the Scroll Control action to change the character. To move one
character to the left, press [4]. Press [.No] twice to delete the current
character. Press [.No] three times to clear the entire alpha tag.
5. Repeat Step 2 until you have entered the desired name. Then press Fto
accept the setting.
Notes:
• Each channel name can be up to 16 characters. Abbreviate as necessary to fit.
• The channel name appears on the second line of the display when the radio
scans or stops on a channel.
• If you do not enter a channel name, the scanner displays the frequency (for
conventional systems) or the talk group ID (for trunked systems) when it stops
on a channel.
Editing Frequencies
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect a conventional system ꢁF
ꢀEdit GroupꢁF
ꢀSelect a channel group ꢁF
ꢀEdit ChannelꢁF
ꢀSelect the channel ꢁF
Edit FrequencyꢁF
Use the [0] to [9] and [.No] keys to enter or modify a frequency. When you press
the first place key, the cursor automatically moves one character to the right. You
can also ꢀ, clockwise or counter-clockwise to highlight any digit.
Editing the Talk Group ID
MEL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a trunked system ꢁF
ꢀEdit Group ꢁF
86
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀSelect a channel group ꢁF
ꢀEdit ChannelꢁF
ꢀSelect the channel ꢁF
ꢀEdit TGIDꢁF
To edit the Talk Group ID, enter the Talk Group ID you want using the number
keys. Then press F.
Setting the Audio Type
MECL
For each channel, you can select the audio type that the channel receives.
[MENU] ꢁProgram SystemꢁF
ꢀSelect the system ꢁF
ꢀEdit Group
ꢀSelect the channel group ꢁF
ꢀEdit ChannelꢁF
ꢀSelect an existing channel ꢁF
ꢀSet Audio TypeꢁF
Select from All, Digital Only, Analog OnlyꢁF
All— The scanner automatically determines whether the audio is analog or
digital.
Digital Only— The scanner only remains on the channel if it is carrying APCO
25 digital audio
Analog Only— The scanner only remains on the channel if it is carrying analog
audio.
If you are programming a conventional system and select Analog Only, the
scanner prompts you to select the CTCSS/DCS tone setting. See the next section.
Selecting CTCSS/DCS Tones
C
To program a channel with a CTCSS or DCS setting, your conventional system
audio must be set to Analog Only first.
[MENU] ꢁProgram SystemꢁF
ꢀSelect the system ꢁF
ꢀEdit Group ꢁF
ꢀSelect the channel group ꢁF
ꢀEdit ChannelꢁF
ꢀSelect the channel ꢁF
Programming Your Scanner
87
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀSet Audio TypeꢁF
ꢀAnalog OnlyꢁF
At this point you can scroll to CTCSS or DCS and select the subaudible frequency
in the CTCSS range or the DCS code.
ꢀCTCSS or DCSꢁF
This setting controls how a sub audible CTCSS or DCS is used for the channel.
Select your setting, then press F.
Off— any signal opens squelch. The default setting is Off.
Search— the scanner searches for and displays any CTCSS or DCS tone that
accompanies the transmission.
CTCSS— the scanner only opens squelch if the CTCSS tone you select is also
present with the signal. The scanner then prompts you to enter or scroll to the
desired tone.
DCS— the scanner only opens squelch if the DCS tone you select is also present
with the signal. The scanner then prompts you to enter or scroll to the desired
tone.
Set Lockout— the scanner does not stop on the channel if the tone you select
is present. The scanner prompts you to select a CTCSS or DCS tone.
Note: The scanner does not detect or decode a P25 digital signal if the channel or
search has CTCSS/DCS search turned on.
Quick CTCSS/DCS Save
If you set a channel to CTCSS/DCS Search and the scanner detects a tone, when
you press [EYES], the first option is Save found CTCSS/DCS?
Setting Channel Modulation Method
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect the conventional system ꢁF
ꢀEdit Group ꢁF
ꢀSelect a channel group ꢁF
ꢀEdit Channel ꢁF
ꢀSelect the Channel ꢁF
ꢀSet ModulationꢁF
88
Download from Www.Somanuals.com. All Manuals Search And Download.
Auto— the scanner uses the default modulation for the channel. The default
setting is Auto.
AM— the scanner uses AM (amplitude modulation) for the channel.
FM— the scanner uses FM (frequency modulation) for the channel.
NFM— the scanner uses narrowband FM for the channel.
WFM— the scanner uses wideband FM for the channel.
WFM(Broadcast) — the scanner uses FM Broadcast for the channel.
This setting controls the modulation method used for the channel. In most cases, if
you leave this set to Auto, the scanner automatically selects the correct
modulation type for the channel you are programming.
Setting Channel Attenuation
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect a conventional system ꢁF
ꢀEdit Group(existing site) ꢁF
ꢀSelect a channel group ꢁF
ꢀEdit ChannelꢁF
ꢀSelect a channel ꢁF
ꢀSet AttenuatorꢁF
This setting controls whether the scanner attenuates signals on this channel.
Select your setting, then press F.
On— the channel is attenuated by about 20 dB.
Off— the channel is not attenuated. The default setting is Off.
You can also toggle this setting by holding on the channel and pressing Fthen [7]
within 2 seconds.
Setting Channel Priority
C
[MENU] ꢁProgram SystemꢁF
ꢀSelect a conventional system ꢁF
ꢀEdit GroupꢁF
ꢀSelect a channel group ꢁF
ꢀEdit ChannelꢁF
ꢀSelect the channel ꢁF
ꢀSet PriorityꢁF
Programming Your Scanner
89
Download from Www.Somanuals.com. All Manuals Search And Download.
This setting controls whether the scanner treats the channel as a priority channel
while scanning. Select Onor Off, then press F.
On— when you turn on the Priority feature, the channel will be scanned every 2
seconds.
Off— the channel will not be treated with priority. The default setting is Off.
Setting Channel Alert
MECL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit GroupꢁF
ꢀSelect a channel group ꢁF
ꢀEdit ChannelꢁF
ꢀSelect the channel ꢁF
ꢀSet AlertꢁF
Off— the scanner does not alert you when the channel becomes active.
Alert 1- 9— the scanner sounds an alert beep to notify you that the channel
has become active. You can choose any of 9 different beep types. Once you
choose an alert tone, then:
ꢀꢁSet Level ꢁF
Auto— the scanner automatically sets the channel alert beep to match the
master volume level.
Level 1- 15— the scanner adjusts the volume of the beep to the level you
select.
Set Record
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit GroupꢁF
ꢀSelect a channel group ꢁF
ꢀEdit ChannelꢁF
ꢀSelect a channel ꢁF
ꢀSet RecordꢁF
On— the scanner outputs the signal.
Off— the scanner does not output any audio.
90
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: In order for the function to work, you must set the channel to record. You
must also set the system’s record option to either All Channel(which will record
all channels regardless of the channel’s record setting) or Marked Channel
(which only records the channels you’ve set to record).
Setting Lockout
MESL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit Group ꢁF
ꢀEdit Channel ꢁF
ꢀSelect a channel ꢁF
ꢀSet Lockout ꢁF
ꢀSelect a channel group ꢁF
Unlocked— the channel is scanned when its quick key is enabled.
Temporary L/O— the channel is locked for this session.
Lockout— the channel is not scanned.
Copying a Channel
MESL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit Group ꢁF
ꢀSelect a channel group ꢁF
ꢀEdit Channel ꢁF
ꢀSelect a channel ꢁF
ꢀCopy Channel ꢁF
You see Copy Channel Copied to Buffer.
Press [MENU] to return to one level before You see Paste Channelas the last
list item. At this point you can paste that channel information to another group or
compatible system.
Deleting a Channel
MESL
[MENU] ꢁProgram SystemꢁF
ꢀSelect a system ꢁF
ꢀEdit Group ꢁF
ꢀSelect a channel group ꢁF
ꢀEdit Channel ꢁF
Programming Your Scanner
91
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀSelect a channel ꢁF
ꢀDelete ChannelꢁF
You see Confirm Delete? Yes= ”E” / No= ”.”
Select one to delete the channel or to cancel.
92
Download from Www.Somanuals.com. All Manuals Search And Download.
Searching and Storing
Service Search
Service Search lets you select and search the scanner’s preprogrammed search
ranges. During service search, the scanner searches starting with the lowest
frequency in the search range you select to the highest frequency in the range.
There are two ways to do this.
[MENU] ꢁꢀSearch for ...ꢁF
ꢀService Search ꢁF
Select the service search range ꢁF
The other approach is:
F+ [SCAN/SEARCH] ꢁF
Quick Search?Yes=”E” / No=”.”
Press [.No] then to select Service SearchꢁF
The following search ranges appear as you scroll ꢀ
Public Safety
News
HAM Radio
Marine
Railroad
Air
CB Radio
FRS/GMRS
Racing
TV Broadcast
FM Broadcast
Military Air
Special
The scanner searches the service you selected, stopping on any transmission it
finds and displaying the frequency. Turn the Scroll Control to change the search
direction. An arrow appears, showing the current search direction.
To pause searching, press [HOLD/RESUME]. To resume searching, press then
press F+ [SCAN/SEARCH]. Or, press [HOLD/RESUME].
Searching and Storing
93
Download from Www.Somanuals.com. All Manuals Search And Download.
To lock out a frequency found while searching, press [L/O] one time to temporarily
lock it out (Temporary L/Oappears) or twice to permanently lock it out (Locked
Outappears).
Notes:
• If all frequencies in the search range you selected are locked out, All
Locked!appears and the scanner does not search the range.
• If the service range you select uses channels (such as CB Radio or Marine),
the scanner displays the service channel number.
Quick Search
Quick Search lets you search from the currently-tuned frequency if you are
scanning a conventional system or sets the system to ID search if you are
scanning a trunked system.
If you are on a conventional system or channel, press F+ [SCAN/SEARCH] to
start quick search. Quick Search? Yes = ”E” / No = ”.”appears. Press
[HOLD/RESUME] to go to quick search hold.
Press [EYES] to start quick search or [.No] to go to the search menu.
Custom Search
Custom Search lets you program and search 10 custom search ranges. You can
search any of these ranges simultaneously and select each custom search range
you set. During custom search, the scanner searches starting with the lowest
frequency in the search range you select to the highest frequency in the range.
There are two methods to begin a custom search.
Notes:
• Search ranges are preset. These ranges can be edited. See “Editing a Custom
Search Range” on Page 95 to change the range.
• You cannot turn off all custom search ranges.
[MENU] ꢁꢀSearch for ...ꢁF
ꢀCustom Search ...ꢁF
The other approach is:
F+ [SCAN/SEARCH]
Quick Search? Yes=”E” / No=”.”
Press [.No] then ꢀto Custom Search ꢁF
94
Download from Www.Somanuals.com. All Manuals Search And Download.
The scanner starts custom search of the custom search range you selected,
stopping on any transmission it finds and displaying the frequency. Turn the Scroll
Control to change the search direction. An arrow appears, showing the current
search direction.
To turn search ranges on or off, press [0] and [1] - [9]. To hold searching, press
[HOLD/RESUME]. To resume searching, press [HOLD/RESUME].
To lock out a frequency found while searching, press [L/O]. There are two different
results based on the number of times you press [L/O].
Press [L/O] 1 time: Temporary L/Oappears
Press [L/O] 2 times: Locked Outappears and the scanner resumes custom
search.
If you turn off the active custom search range, the scanner skips to the next
custom search range and continues searching.
Note: If all frequencies in all active custom search ranges are locked out, All
Locked!appears and the scanner does not stop.
Editing a Custom Search Range
You can edit up to 10 custom search ranges. The names of the custom search
ranges appear on the display. The default custom search range names appear as
Custom 1, Custom 2, and so on.
[MENU] ꢁꢀSearch for ...ꢁF
ꢀ Edit Custom ꢁF
ꢀ Custom 1, Custom 2 to Custom 10.ꢁF
Another approach is
F+ [SCAN/SEARCH]
Quick Search? Yes=”E” / No=”.”
Press [.No] then ꢀto EditCustom ꢁF
At this point you can edit each of the settings that comprise a custom search.
Edit Name— lets you edit the custom search range’s name.
Edit Srch Limit— lets you view and select the frequency ranges to search.
The scanner prompts you to enter the upper and lower search limits.
Searching and Storing
95
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Delay Time— lets you set the amount of time the scanner will delay before
continuing to search after a transmission ends.
Set Modulation— lets you set the custom search range’s modulation type.
Set Attenuator— lets you set whether the scanner will attenuate reception by
20 dB during search.
Set Data Skip— lets you set whether the scanner will skip data transmissions
during search.
Set Step— lets you set the custom search range’s step (the gap between
frequencies).
Set C-Ch Only— lets you search for a Motorola control channel. If it finds one,
the scanner scans the system.
Set Record— if during your listening to the selected service, if a transmission is
received, choosing Onwill send an audio signal to the connected audio recording
device.
Adjust P25 Level— adjusts the digital decode threshold to match the
transmission you are hearing when it receives a strong signal and has a high
decode rate.
Search with Scan — sets whether the scanner includes the custom search
during scanning. If unlocked, the scanner first scans all selected systems, then
searches the selected service searches for the selected hold time (0-255
seconds).
Within this menu item are the following settable options
Set Quick Key— lets you assign a Quick Key for the custom search range.
Set Startup Key— lets you decide which custom search range should be
unlocked and scanned at power up
Set Lockout— lets you lock the custom search range for this session or
permanently as with any other L/O action.
Set Hold Time— sets how long (seconds) the custom search range is checked
before the scanner moves to the next programmed entry.
Search With Scan
When you press [SCAN/SEARCH] the BCD996T starts a scan of those sites,
channels, etc you have manually programmed or the Uniden preprogrammed data
96
Download from Www.Somanuals.com. All Manuals Search And Download.
for your metropolitan area that are unlocked and have their System Quick key
enabled.
In addition to this scan you can search any of the preprogrammed service or
custom search ranges.
While scanning, press F. Rotate the Scroll Control until you reach the desired
service or custom search range. Press [L/O] to unlock it. You can also assign a
System Quick Key to the search to make it easy to quickly enable/disable the
search range for search and scan. The Search with Scan Hold time determines
how long the scanner stays on a search before moving on. The default is 2
seconds. Fto set the Search with Scan settings.
Editing a Service Search
You can change the way service search works for each service. There are also two
methods to reach the point of editing.
Method One
[MENU] ꢁꢀSearch for ...ꢁF
ꢀ Edit Service ꢁF
ꢀSelect a service range:
Public Safety, News, HAM Radio, Marine, Railroad, Air, CB
Radio, FRS/GMRS, Racing, TV Broadcast, FM Broadcast, Military
Air, SpecialꢁF
Method Two
F+ [SCAN/SEARCH]
Quick Search? Yes=”E” / No=”.”
Press [.No] then ꢀto EditService ꢁF
At this point you can edit each of the settings that comprise each custom search
range.
The following show you how to set the various option settings associated with a
Service. For each, your starting operation is
[MENU] ꢁꢀSearch for ...ꢁF
ꢀ Edit Service ꢁF
ꢀSelect a service range:
Searching and Storing
97
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Delay Time
Choose a delay time to set how long the scanner stays on a transmission after it
ends.
ꢀto select a value from 1 sec, 2 sec, 3 sec, 4 sec, 5 sec, and Off. ꢁF
Set Attenuator
Choose to attenuate all frequencies by about 20 dB.
ꢀto select to choose an attenuation for all frequencies in the range. ꢁF
On— the frequencies are attenuated.
Off— the frequencies are not attenuated.
Set Record
ꢀto enable real time audio output from REC to an audio recording device.
On— the scanner outputs the signal. Then press Fto select.
Off— the scanner does not output any audio. Then press Fto select.
Assigning a Search Range to a Search Key
You can assign any of the Service or Custom Searches to the six Search keys for
quick access to your favorite searches.
[MENU] ꢁꢀSearch for ...ꢁF
ꢀSet Search KeyꢁF
ꢀSelect the key to assign ꢁF
ꢀSelect a search range ꢁF
[MENU] ꢁꢀSearch for ...ꢁF
Now, to access that search, hold on any channel, then press Fand the number
key [1] to [6] corresponding to the search range.
The default settings are:
SRCH 1: Custom 1
SRCH 2: Public Safety
SRCH 3: Railroad
SRCH 4: FRS/GMRS
SRCH 5: TV Broadcast
SRCH 6: FM Broadcast
98
Download from Www.Somanuals.com. All Manuals Search And Download.
Saving a Found Channel (Quick Save)
If you hold on a channel or receive a desired channel, you can save it by pressing
[EYES] instead of using Direct Entry. The alpha data is also stored.
If a GPS unit is attached, the longitude and latitude data is saved and becomes the
name of that channel. For example, if the position is 32°57’33.60 N latitude and
97°05’34.18 W longitude, the name saved is 3257.33-09705.34.
Auto Search and Store
Your scanner’s Auto Store feature lets you search for new frequencies in custom
search ranges or within a service search range on a conventional system, or new
talk group ID’s on a trunked system.
Selecting a System to use for Storing
To store frequencies or talk group ID’s you find during Auto Store, you must first
select a system where the frequencies or talk group ID’s will be stored.
[MENU] ꢁꢀSearch for ...ꢁF
ꢀSearch and StoreꢁF
ꢀSelect the system for storing the frequencies or talk group IDs ꢁF
If no system is selected, No System Storedappears. If you have already stored
too many channels or channel groups, Over Limitappears.
Conventional Search and Store
You can store frequencies into the system you selected in “Selecting a System”
above. Otherwise, the scanner stores frequencies in a new group it creates.
Follow the steps in the preceding section but be sure to select a Conventional
System. A search option appears that lets you choose from a Custom Searchto
the other service search ranges previously mentioned (Public Safety, News…etc).
Turn the Scroll Control until the search range you want appears, then press Fto
select it. One of the search ranges appears.
If frequencies in your selected search range are all locked out, All Locked!
appears and the scanner does not store any frequencies.
When you select a search range, the scanner looks for active frequencies within
that range. The top line of the display alternates between the system name and the
search range name while SEARCH AND STOREappears beneath it. The second
Searching and Storing
99
Download from Www.Somanuals.com. All Manuals Search And Download.
line changes to Memory Checkwhen the scanner detects a transmission while it
is checking to see if the frequency has already been stored.
When the scanner finds an active transmission, it checks to see if the frequency
has already been stored in the system. If it has already been stored, the scanner
continues to search. If the frequency has not been stored, it stores the frequency
into a group named Found Channels, then resumes searching. The scanner
creates this group if it doesn’t already exist.
Trunked Search and Store
You can store talk group ID’s into the system you selected in “Selecting a System”.
Otherwise, the scanner stores talk group ID’s in a new group it creates.
Note: Trunked system search and store does not work if an EDACS SCAT system
is selected, a system with no frequency is selected, the quick key to which the
system belongs is turned off, and the group you selected to store found talk group
ID’s contains more talk group ID’s than the maximum set in Max Auto Store.
To store a trunked system, follow the beginning steps in Selecting A System
above. When you select a Trunked System and press F, the scanner enters TGID
Search and Store mode.
When you select a trunked system, the scanner looks for active talk group ID’s
within that range and ID SEARCH AND STOREappears and scrolls across the
display’s lower line while the system/site name appears on the display’s upper line.
When the scanner finds an active talk group ID, it checks if the talk group ID has
already been stored in the site. If it has, the scanner continues to search. If the talk
group ID has not been stored, it stores the talk group ID into a group named
Found Channels, then resumes searching. The scanner creates this group if it
does not already exist.
100
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the Close Call Feature
Your scanner’s Close Call™ feature lets you set the scanner so it detects, displays
the frequency of, and lets you hear a nearby strong radio transmission. You can
set the scanner so the Close Call feature works “in the background” while you are
scanning other frequencies, turn off normal scanning while the Close Call feature
is working, or turn off the Close Call feature and use the scanner normally. You can
set the scanner so it alerts you when the Close Call feature finds a frequency. You
can also set the frequency band where you want the scanner to look for
transmissions.
To toggle Close Call mode, press [SQ/C]. When the feature is on, CC DND(c) or
CC Pri(C) and their indicating icons appear on the display. Using CC Priority,
normal operation is briefly interrupted about every 2 seconds.
Notes:
• The Close Call feature works well for locating the source of strong local
transmissions such as mobile and handheld two-way radios in areas with no
other strong transmission sources. Several factors affect Close Call
performance, however. Performance is increased with higher transmit power,
receive antenna tuned to the target band, and a low background RF level.
Other than the antenna, you have no control over these factors, but they
explain why performance might vary by both location and time.
• The Close Call feature cannot detect satellite dishes or any transmitter with a
frequency above or below the frequency ranges listed under the Set CC
Bands: option on Page 97.
• The Close Call feature works better with some types of transmissions than
others. It might not correctly display frequency information for transmitters
using a highly directional antenna (such as an amateur radio beam antenna) or
if there are many transmitters operating at the same time in the same area.
Setting Close Call Options
[MENU] ꢁꢀClose CallꢁF
Next, turn the Scroll Control ꢀto select an option.
Close Call Only— Lets you set the scanner only for Close Call searching. The
scanner does not scan frequencies or channels when this option is turned on. To
select this option, press F.
CC Auto Store— Lets you select whether the scanner automatically stores
Close Call hits into channels. If you turn this option on, the scanner starts Close
Using the Close Call Feature
101
Download from Www.Somanuals.com. All Manuals Search And Download.
Call mode and stores any Close Call hits, up to the maximum you specified in the
Max Auto Store setting. If the scanner stores more hits than this setting, it stops
auto store operation.
Turn the Scroll Control ꢀto display an option, then press F.
Set CC Mode— Lets you select the Close Call mode. If you set CC Pri, then
every 2 seconds the scanner switches the filter settings to the ones set by the CC
Bands option. This does not occur with CC DND.
Off— Close Call is turned off for all modes.
CC DND(Do Not Disturb) — The scanner checks for a Close Call hit every 2
seconds only if the scanner is not currently stopped on a transmission. If the
scanner is on a transmission the scanner waits until the signal ends to perform a
Close Call check. This prevents breaks in audio during Close Call checks.
CC Pri(Priority) — Checks for a Close Call hit every 2 seconds.
Set CC Override— Lets you select how the Close Call feature works with other
scanning activities. If you turn this option off, when the scanner detects a Close
Call signal, CC Found! PressFunc Keyappear for the time you set in Set CC
Pause. Press Fwhen this appears to jump to and hold on the frequency.
If this option is turned on, the scanner overrides the current channel and goes to
the Close Call hit. The scanner displays CC Found! Press Any Key. When you
press a key, the frequency appears.
Set CC Alert— Lets you select how the scanner alerts you when it receives a
Close Call signal. You can select from these options.
Select Beep— The scanner beeps when it receives a Close Call signal. You
can set the beep alert in the following manner.
Off— the scanner does not beep
Alert 1-9— The scanner sounds a specialized beep to notify you of a Close
Call hit. When you select an alert type, the scanner automatically enters the setting
of the Alert volume level. Each alert has a unique one or sound pattern.
Set CC Pause— Lets you select how long the scanner waits after a hit before it
returns to the previous operation. Your options are:
3/5/10/15/30/45/60 sec.
Infinite— The scanner stops and requires you to manually select another
operation to enable its return.
102
Download from Www.Somanuals.com. All Manuals Search And Download.
Set CC Bands— Lets you select the Close Call band settings. You can turn the
following bands on or off.
VHF Low 1 — (25.0000 - 53.9800 MHz)
VHF Low 2— (54.0000 - 107.9000 MHz)
Air Band— (108.0000 - 136.9750 MHz)
VHF High 1— (137.0000 - 224.9800 MHz)
VHF High 2— (225.0000 - 319.9750 MHz)
UHF— (320.0000 - 512.0000 MHz)
800MHz+— (764.0000 - 775.9875 MHz, 794.0000 - 823.9875 MHz, 849.0125 -
868.9875 MHz, 894.0125 - 956.0000 MHz,1240.000 - 1300.0000 MHz)
Use the Scroll Control ꢀto select a band, press F, then use the Scroll Control
to select Onor Offand press F. Turning off undesired bands speeds up Close
Call operation (works for all frequencies listed above).
Close Call Hits
When the scanner detects a Close Call hit, it alerts you according to the Override
and Alert settings in the previous section.
While listening to a Close Call hit, you can press [HOLD/RESUME] to hold on the
hit frequency, press Fto quickly save the frequency into memory, press [L/O] to
lock out the frequency from Close Call and Search operation, or wait for the
transmission to end. If you are in Close Call Only or Close Call Override mode,
and you do not press any key, the scanner returns to its previous operation after
the transmission ends and the set delay time expires.
If you are holding on the frequency, press [HOLD/RESUME] again to resume the
previous operation.
Close Call Hits are just the last 10 hits received in Close Call mode. The hits go
away when you cycle power (if you want to store it “permanently” press Fwhen
the scanner is on the frequency; the scanner then stores the frequency into the
“Close Call” system which does show up in the systems list).
Close Call Hits with Scan
When you turn on this option, the scanner automatically stores and scans the last
10 Close Call hits received. You can assign a Quick Key to this special scan and
you can also set how long the scanner will wait after the signal stops before
Using the Close Call Feature
103
Download from Www.Somanuals.com. All Manuals Search And Download.
resuming scan. This lets you continue to hear transmissions detected with the
Close Call feature, even after you are no longer close enough to receive it as a
Close Call hit. Follow these steps to set up the option.
[MENU] ꢁꢀClose CallꢁF
ꢀHits with ScanꢁF
ꢀSet Quick Key or Set Lockout or Set Hold TimeꢁF
Set the available option as you would for other menu items.
This special channel group is automatically cleared whenever you cycle the
scanner’s power. To permanently save one of the channels, press [EYES] when the
scanner is stopped on one of the frequencies. To keep the scanner from
repeatedly stopping on an annoyance hit, press [L/O] when the scanner stops on
the frequency.
104
Download from Www.Somanuals.com. All Manuals Search And Download.
Search and Close Call Options
The settings in this section affect custom searches, service searches, and Close
Call operation. The following table shows what options are available for various
search modes.
Service
Search1
Custom
Search1
Quick
Search and Store
Search
CC Auto
Store
CC Hits
System
Setting
Close Call
Freq. Lockouts
•
•
•
•
•
•
•
•
•
•
•
2
Broadcast
Screen
CTCSS/DCS
Search
•
•
•
•
•
•
•
•
•
Repeater Find
Max Auto Store
Set Delay Time
Set Modulation
Set Attenuator
Set Data Skip
Set Step
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
3
•
•
•
Set Record
•
•
•
•
Adjust P25
Level
1 — Valid only for searching a range using Search with Scan.
2 — Valid only for storing a frequency from Search and Store.
3 — Valid only for storing a frequency from Service Search.
Managing Locked-Out Frequencies
While searching or during Close Call operation, if you press [L/O] while the
scanner is stopped on a frequency, that frequency is locked out of these modes.
The temporary L/O frequency limit is 250. The permanent L/O frequency number
limit is up to 250.
Search and Close Call Options
105
Download from Www.Somanuals.com. All Manuals Search And Download.
Unlocking All Frequencies
[MENU] ꢁꢀSrch/CloCall Opt ꢁF
ꢀFreq Lockouts ꢁF
ꢀUnlock AllꢁF
The scanner prompts you to confirm the change in lockout status. To confirm the
change of all locked-out frequencies, press F. If no frequencies are locked, you
see Nothing Locked Press Any Key. Otherwise, to cancel, press [MENU].
Reviewing Locked-Out Frequencies
[MENU] ꢁꢀSrch/CloCall Opt ꢁF
ꢀFreq Lockouts ꢁF
ꢀRvw Search L/OꢁF
The scanner displays the first locked-out frequency and prompts you to unlock the
frequency. Press Fto unlock the frequency. Or, rotate the Scroll Control or press
to select a different frequency. If there are no frequencies to review, you see
Nothing Locked Press Any Key. Otherwise, to cancel, press [MENU] to
backstep.
Searching for Subaudible Tones
[MENU] ꢁꢀSrch/CloCall Opt ꢁF
ꢀCTCSS/DCS Search ꢁF
ꢀOn or OffꢁF
This setting controls whether the scanner will search for a subaudible tone when it
stops on a transmission during search or Close Call operation.
On— The scanner searches for and displays any subaudible tone found.
Off— The scanner does not search for subaudible tones.
Note: This feature does not operate when the scanner is in AM/WFM/FMB
modulation mode.
Screening Out Broadcast Sources
[MENU] ꢁꢀSrch/CloCall OptꢁF
ꢀBroadcast ScreenꢁF
106
Download from Www.Somanuals.com. All Manuals Search And Download.
This setting determines whether the scanner automatically ignores transmissions
found during Custom Search, Quick Search, or Close Call operation that are on
common broadcasts, paging systems, and other annoyance radio sources.
Note: Broadcast screening does not work in All service search ranges.
Set All Band On— turns on broadcast screen on each band.
Set All Band Off— turns off broadcast screen on each band.
Set Each Band— lets you set broadcast screen only on specific bands you
select. Onor Offappears next to each option. Turn the Scroll Control to select
an option then press Fto change the setting.
Pager — the scanner skips known paging system frequencies.
FM— the scanner skips known FM frequencies.
UHF TV— the scanner skips known UHF TV frequencies.
VHF TV— the scanner skips known VHF TV frequencies.
NOAA WX— the scanner skips known NOAA weather frequencies.
Band 1-10— select the custom band where you want to screen out broadcast
sources.
ꢀProgram Band— brings you to a menu setting to let you program a custom
frequency range for broadcast screen. Turn the Scroll Control to select an option
then press Fto change the following setting.
To set the custom range of a band, select one and press Fto set the limit.
Band 1-10— select the group where you want to screen out broadcast sources.
Set Lower Limit— enter the lower limit of the frequency range, then press F
to set it.
Set Upper Limit— enter the upper limit of the frequency range, then press F
to set it.
To set the custom range of a band, select one and press Fto set the limit.
Finding Repeater Output Frequencies
[MENU] ꢁF
ꢀSrch/CloCall OptꢁF
Search and Close Call Options
107
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀRepeater FindꢁF
ꢀOnor Off ꢁF
This feature sets whether the scanner tries to tune to a repeater output frequency
during Custom Search, Quick Search, or Close Call operation when it detects a
transmission on a repeater input frequency. Since you can normally only hear one
side of a conversation when you listen to an input frequency transmission, turning
this feature on can let you hear both sides of the conversation where a standard
difference frequency is set between the input and the output, to and from the
repeater.
On— The scanner automatically applies repeater reverse to detected
transmissions. If the scanner detects the transmission on the output frequency, it
beeps, Repeater Foundappears, and it remains on the output frequency until
transmissions end. If it does not detect a transmission on the output frequency, it
remains on the original frequency.
Off— The scanner does not try to find the output frequency.
Setting the Maximum Auto Store Value
[MENU] ꢁꢀSrch/CloCall OptꢁF
ꢀMax Auto StoreꢁF
This value sets how many hits the scanner will automatically store when it is in
either Search and Store or Close Call Auto Store mode. Use the number keys to
enter a value from 1 - 256, then press F. The default value is 100.
When the scanner exceeds the maximum number of hits you set, it stops the
auto-store operation.
Setting the Modulation Type
This setting controls the modulation method used to receive frequencies during
Quick Search and Close Call operations. In most cases, if you leave this set to
Auto, the scanner automatically selects the correct modulation type for the system
you are programming.
[MENU] ꢁꢀSrch/CloCall OptꢁF
ꢀSet ModulationꢁF
Auto— the scanner uses the default modulation for the frequency band. The
default setting is Auto.
108
Download from Www.Somanuals.com. All Manuals Search And Download.
AM— the scanner uses AM (amplitude modulation) for the frequency band.
FM— the scanner uses FM (frequency modulation) for the frequency band.
NFM— the scanner uses narrowband FM for the frequency band.
WFM— the scanner uses wideband FM for the frequency band.
WFM(Broadcast) — the scanner uses FM Broadcast for the frequency band.
Setting Attenuation
Turn on this setting if you are near other strong signal sources. Attenuation
sometimes helps to reduce interference and desensitization that strong signals
create.
[MENU] ꢁꢀSrch/CloCall OptꢁF
ꢀSet AttenuatorꢁF
This setting controls the attenuator for Quick Search and Close Call operation.
Select your setting, then press F.
On— Reception is attenuated by about 20 dB.
Off— Attenuation is off.
Setting Data Skip
[MENU] ꢁꢀSrch/CloCall OptꢁF
ꢀSet Data SkipꢁF
This setting controls how the scanner behaves when it stops on a channel that has
a data signal.
On— the scanner stops briefly on the channel, but then immediately resumes
scanning automatically.
Off— the scanner remains on the channel until the transmission stops. The
default setting is Off.
Note: If you are trying to test the Close Call feature with a nearby transmitter (such
as a CB) and you do not talk into the transmitter, the scanner detects this
unmodulated carrier as data and skips the frequency when Data Skip is on. Turn
the feature off or talk into the transmitter to modulate the carrier.
This setting is ignored for AM/WFM/FMB channels.
Search and Close Call Options
109
Download from Www.Somanuals.com. All Manuals Search And Download.
Setting the Delay Time
[MENU] ꢁꢀSrch/CloCall OptꢁF
ꢀSet Delay TimeꢁF
This setting determines how long the scanner waits after a transmission ends
before resuming Quick Search or Close Call operation.
1-5 sec— The scanner waits the set amount of time after the transmission ends
before resuming. The default setting is 2 sec.
Off— The scanner resumes immediately when the transmission ends.
Setting the Search Frequency Step
[MENU] ꢁꢀSrch/CloCall OptꢁF
ꢀSet StepꢁF
This setting lets you select the frequency step used during Quick Search and
Close Call.
Auto— The step is based on the band (see the table at the front of the manual).
This is also the default setting.
5.0 kHz, 6.25kHz,
7.5 kHz,8.33kHz,
10.0 kHz, 12.5 kHz,
The scanner uses the selected step.
15.0 kHz, 20.0 kHz,
25.0 kHz, 50.0 kHz,
100.0 kHz
Setting Record
You can set the REC jack to provide an audio signal to a sound recording device
(tape, PC, flash memory) for live recording of transmissions. This also lets you
record Quick Search and Close Call transmissions.
[MENU] ꢁꢀSrch/CloCall OptꢁF
ꢀSet RecordꢁF
On— enables an output to an audio recorder at the REC (record output) jack.
Off— disables an audio signal at the output jack.
110
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjust P25 Level
You can select the best threshold for the APCO mode.
[MENU] ꢁꢀSrch/CloCall OptꢁF
ꢀAdjust P25 LevelꢁF
Auto— The automatic adjust feature is enabled.
Manual— you can set the threshold manuals depending on your circumstances.
Default— sets the factory default value.
Note: Applies to P25 signals received during Search and Close Call.
Priority Scan
If you activate a Priority Scan while scanning, the radio interrupts its scan every
two seconds to check the priority channel (P-Ch). PRIappears on the screen.
There are two ways to set Priority Scan.
1. Press [PRI] to set one of the following Priority Scan levels in Scan / Scan Hold
mode.
Off— Normal scanning. The scanner provides no special treatment for Priority
Channels.
On— The scanner scans all unlocked channels and also checks those designated
as Priority. While scanning a conventional system, the scanner interrupts every 2
seconds and checks the priority channels in each unlocked conventional system.
Priority channels in lower priority key numbered systems (starting from 1) have
highest priority. PRIappears when you select this mode.
Plus On— The scanner only scans priority channels in unlocked conventional
systems. PRIflashes when you select this mode.
2. You can choose how the scanner treats Priority Channels using the Menu
options.
Search and Close Call Options
111
Download from Www.Somanuals.com. All Manuals Search And Download.
[MENU] ꢁꢀSetPriorityꢁF
ꢀChoose Off, On, or Plus OnꢁF
112
Download from Www.Somanuals.com. All Manuals Search And Download.
Using Weather Alert (SAME)
Your BCD996T has been primarily designed as a multi-band, general services
scanner. While it incorporates a weather alert ability as one of its features, we
recommend that you not use the scanner as your sole means for receiving
emergency alerts. Your local electronics retailer can supply a selection of weather
radios that are dedicated to weather service monitoring including SAME alerts.
Such radios can be more dependable for this application.
Your scanner allows you to search for a local NOAA weather broadcast and set it
to alert when a SAME (Specific Area Message Encoding) weather alert is
broadcast on a NOAA channel. You can also program SAME codes into the
scanner and set a weather channel as a priority channel.
Searching For a Weather Broadcast
[MENU] ꢁꢀWX OperationꢁF
ꢀWeather ScanꢁF
F+ [WX] Press and Hold
The scanner starts scanning the preprogrammed weather frequencies, and stops
on the first signal. Generally, there will be one channel of the ten that you will
receive best. If this station is weak, rotate the Scroll Control ꢀto check for other
weather broadcasts in your area.
Note: NOAA broadcasts are continuous broadcasts. You only lose reception if you
move out of a coverage area. If the signal is lost, the scanner resumes searching
for a weather transmission.
Using Weather Alert (SAME)
113
Download from Www.Somanuals.com. All Manuals Search And Download.
Turning Weather Alert On/Off
In weather alert mode, your scanner functions as a severe weather warning radio.
This is especially useful when your area is expecting severe weather conditions
late at night. When you set the scanner to weather alert mode, it holds on the
weather channel, but does not play the channel’s audio. If it detects a weather
alert, it sounds a tone, displays information about the weather alert, and turns on
the audio so you can hear the weather broadcast.
[MENU] ꢁꢀWX OperationꢁF
ꢀWeather AlertꢁF
F+ [WX]
This setting determines which types of signals will trigger an alert. Choose your
setting, then press F.
Alert Only — the scanner alerts when it detects the 1050 Hz tone that
accompanies all weather alerts.
SAME 1-5— the scanner alerts and displays information about the weather alert
when it receives a weather alert signal that includes any FIPS code you have
programmed into the specified SAME group.
All FIPS— the scanner alerts and displays information about the weather alert
when it receives any FIPS code.
Programming a SAME Group
You can edit any of the 5 SAME groups in your scanner. Each group can have up
to 8 FIPS codes.
SAME (Specific Area Messaging System) is a system developed by the National
Weather Service to reduce the number of alerts received by consumers by
allowing them to hear alerts only for the counties in which they have interest such
as where they live or work. Each alert contains information about the type and
severity of the alert, as well as the specific geographic locations affected by the
alert.
The geographic locations are designated using FIPS codes. Each county or parish
in the US and its territories are assigned a FIPS code. In addition, certain special
regions and wildcard settings can be assigned.
FIPS codes are in the format nSSCCC:
n: A special sub-county designator. For an entire county, use 0.
114
Download from Www.Somanuals.com. All Manuals Search And Download.
SS: The state code.
CCC: The county code.
For example, Tarrant County in Texas is assigned to FIPS code 048439.
0 indicates the entire county
48 indicates the state of Texas
439 indicates Tarrant County
To get the FIPS code for your county, visit the National Weather Service web site
at http://www.nws.noaa.gov and search for “FIPS Listing”.
[MENU] ꢁꢀWX OperationꢁF
ꢀProgram SAMEꢁF
Select the SAME group to edit ꢁF
Edit Name— enter the name you want to assign to the SAME group you
selected.
Edit County— select the position you want to store the FIPS code into, then
press F, enter the FIPS code, and press Fagain.
Setting WX Alert Priority
Enabling this setting, assigns priority to weather scanning no matter what else the
radio might be doing. Checking the weather channel every 5 seconds assures you
of the latest check of a NOAA warning.
[MENU] ꢁꢀWX OperationꢁF
ꢀWX Alt PriorityꢁF
ꢀMake your choice:
On— the scanner checks the weather channels every 5 seconds for a 1050 Hz
weather alert signal. Press Fto select.
Off— the scanner does not check the weather channels. This is the default
setting. Press Fto select.
Notes:
• You can also turn this option on and off by pressing the front-panel [WX] key.
• When you turn on this option, you will notice a break in the audio every 5
seconds as the scanner checks for the weather alert signal.
Using Weather Alert (SAME)
115
Download from Www.Somanuals.com. All Manuals Search And Download.
Fire Tone-Out
Your scanner can be set to respond to fire tone-outs, a system comprised of
standardized two-tone sequential paging, short one-tone paging, and long group
tone paging. You can save up to 10 settings. When you select a setting in standby
mode, the scanner also monitors for any other setting that uses the same transmit
frequency, modulation, and attenuation settings. To quickly switch to Fire Tone-Out
mode, press Fand then [SQ].
You need tone-out setup information from the agency you wish to monitor. Check
with your local agency or on-line resources as Uniden America Corporation has no
information regarding local tone-out systems.
Setting Tone-Out Standby
[MENU] ꢁꢀTone-Out for...ꢁF
ꢀTone-Out Standby ꢁF
Turn the Scroll Control ꢀto select which of the ten tone-outs to monitor. Or,
while holding on any channel, press Fthen [SQ] to quickly switch to Tone-Out
Standby, then rotate scroll to select the settings to monitor. All tone-outs that have
the same frequency, modulation, and attenuation setting as the one you select, are
also monitored.
In standby mode, the display cycles through all monitored tone-out settings.
Regardless of the current display, the scanner always alerts on any received
tone-out that matches a stored setting.
If you press [HOLD/RESUME] while in standby mode, the scanner temporarily
exits the mode and you hear all transmissions on that frequency. No alerts sound,
even if a tone-out matches one you have stored. Press [HOLD/RESUME] again to
return to standby mode.
Setting Up Tone-Out
[MENU] ꢁꢀTone-Out for...ꢁF
ꢀTone-Out Setup ꢁF
Scroll to select the tone-out (1 - 10) you want to program, then press F. Then you
can scroll to any of the following settings and press Fto select and modify the
selected settings:
Edit Name— Sets the name for the selected tone-out setting.
Set Frequency — Sets the tone-out’s RF frequency parameters. Then select:
116
Download from Www.Somanuals.com. All Manuals Search And Download.
• Edit Frequency — Enter the desired frequency that the scanner should
monitor for the tone-out.
• Set Modulation— Set the modulation type for the paging signal. Next
choose the modulation setting:
• Auto— The scanner uses the default modulation for the frequency band. If
the default modulation is AM, WFM, or FMB, the modulation operates as
FM.
• FM— The scanner uses FM for the frequency band. This is the default
setting.
• NFM— The scanner uses NFM modulation.
Set Attenuation— Turn the Scroll Control to select Onor Off.
Set Tone— Sets the audio tone frequency for the page. Then choose the Tone
setting.
• Edit Tone A— Set the audio frequency for Tone A
• Edit Tone B— Set the audio frequency for Tone B
Notes:
• For two-tone pages, enter a value for A and B.
• For one-tone pages using short tones of less than 3.75 seconds, enter the tone
value for A, and 0 (zero) for B.
• For long-tone pages, such as group pages of more than 3.75 seconds, enter 0
(zero) for A and the tone value for B.
Set Delay Time— Sets the time the scanner remains in monitor mode after the
scanner receives a page and the carrier drops.
• 1-5 sec— the scanner resumes standby mode after the carrier drops and
the selected time expires.
• Infinite— you must press [HOLD/RESUME] after a page to resume
standby mode.
• Off— the scanner resumes standby as soon as the carrier drops after a page.
Set Alert— Sets the alert the scanner uses when it receives an alert.
• Alert 1- 9— scroll to select the alert tone pattern, The scanner sounds
each alert as you scroll to its numbered value.
• Off— the scanner does not sound an alert.
Fire Tone-Out
117
Download from Www.Somanuals.com. All Manuals Search And Download.
After you select an alert pattern, the scanner prompts for the alert level for a
received alert. Level options 1 to 15 sets a fixed audio level independent of the
main volume setting. AUTOuses the main volume setting for the alerts.
Tone-Out Multi-Channel Monitoring
The scanner can check multiple tone combination pages for channels whose
settings are the same. To achieve this, set the channel to the same frequency,
modulation, and attenuation. For example, the scanner checks tone combinations
for channel 1 to channel 3 for the following settings.
Frequency (MHz) Modulation
Attenuator
Off
Tone A (Hz)
1000.0
Tone B (Hz)
2000.0
Ch 1
Ch 2
Ch 3
Ch 4
Ch 5
Ch 6
137.0000
137.0000
137.0000
137.0000
137.0000
138.0000
Auto (NFM)
Auto (NFM)
Auto (NFM)
NFM
Off
Off
Off
Off
Off
2200.0
3200.0
1500.0
2500.0
1800.0
2800.0
FM
2000.0
3000.0
Auto (NFM)
1000.0
2000.0
Although set to Auto, if the band default is anything other than FM or NFM,
modulation will always be FM.
If you switch to Tone-Out Standby Mode for Multi-Channel Monitoring, the display
switches every 2 seconds to show the frequency it is checking. However, it is, at
the same time, checking all frequencies for Tones. If one is detected, it switches to
Tone-Out Hold mode.
Set Record
ꢀto enable real time audio output from REC to an audio recording device.
On— the scanner outputs the signal to REC. Press Fto select.
Off— the scanner does not output any audio. Press Fto select this option.
118
Download from Www.Somanuals.com. All Manuals Search And Download.
Using the BCD996T with a GPS
The scanner lets you connect a compatible GPS device to it to provide two very
convenient operation features:
• automatically locks and unlocks systems and sites based on data you input.
This fine-tunes the scanning operation and makes it that much enjoyable.
• provides you with valuable displayed information and audio alerts for Points of
Interest, Dangerous Roads, and Dangerous Crossings. The GPS works in
close coordination with your scanner.
Device Compatibility
The GPS must have serial output, and capable of outputting standard NMEA
sentences GGA and RMC. (See “NMEA-0183 ver.3.01” which can be found on the
web.)
Connecting Your Scanner to a GPS Device
To use the location-based features of the scanner, you must connect a GPS to the
unit. Use the cable provided by the GPS manufacturer. Make sure that their cable
terminates in a female, 9-pin serial connector. Insert that plug into the male, 9-pin
socket on the back of the scanner labeled REMOTE/GPS. Once the GPS is
connected, refer to the following sections dealing with inputting selections to
enable location based feature operation.
Initial Scanner/GPS Operation
When the scanner first starts receiving a signal from the GPS, it briefly displays
GPS Connectedand silently locks and unlocks all radio system and sites whose
quick key is enabled according to your current location. If you have a lot of data
programmed, it might take the scanner a couple of minutes to complete the
process. Once the scanner completes the initial GPS review, if you move into or
out of an area covered by a radio site, the scanner beeps and displays the name of
the system and whether it is being locked or unlocked.
Note: The GPS function temporarily locks out sites and systems when you move
out of their range. If you cycle power, all systems are unlocked until the scanner
reacquires the GPS signal and completes the initial GPS review.
Using the BCD996T with a GPS
119
Download from Www.Somanuals.com. All Manuals Search And Download.
Location-Based (GPS) Scanning
The BCD996T uses data, supplied by an attached GPS unit, that lets the radio
automatically unlock and lockout sites based on the geographical information you
provide.
• Latitude (the center of the range or site)
• Longitude (center of the range or site)
• Range (the radius of a circle around the latitude and longitude coordinates
selected from up to 50 miles form that center.
You set the longitude and latitude to approximate the center of a geographic entity
such as your local city. Then set the range to encircle that center point. By doing so
the scanner automatically locks out reception of an area outside that circle.
All geopolitical areas are rarely perfect circles. You can accommodate these
variations by entering multiple sites for the system, even though the system
actually has only one site, and use different location settings for each of those
additional sites.
Figure A shows, schematically, an ideal reception situation. The area almost
matches the site area. But Figure B is more like the real world. How do you
effectively match the narrow geographical area to the circular site transmission?
Figure C shows the answer. You create multiple sites for the scanner. You program
the longitude and latitude, and the range, of each of the three sites to more closely
match the geographic area.
Figure A
Figure B
Figure C
120
Download from Www.Somanuals.com. All Manuals Search And Download.
Another Example of Multiple Site
Creation
The geographic area of Arlington,
TX, is separated into multiple site
locations to enable automatic
lockout and unlock as one moves
from area to area.
Non-Radio Location Based GPS Features
When connected to a GPS, you can program specific location information which
will trigger an alert from the scanner. The scanner becomes an extension of the
GPS device.
The following geographical values are typical of use you might find valuable while
traveling. Use the menu (begin with Program Location) to input the necessary
data to enable each.
• Dangerous Xing — Stores location, speed, and direction of travel. If you are in
range, traveling greater than the set speed, and moving in the selected
direction, the radio sounds an alert at .5, .25, and .1 miles (radius of a circle)
from the point. These range distances are automatic and fixed.
• Dangerous Road — Stores location, direction of travel, and speed. If you are
traveling at a speed greater than that specified, in the direction specified, and if
you are within range of the set location, the scanner sounds an alert at .5, .25,
and .1 miles from the point. These range distances are also automatic and
fixed.
• Points of Interest (POI) — Stores location and range. If you approach the set
location, the radio sounds an alert up to 2 miles from the center.
Press F+ [GPS] to choose a setting for Dangerous Xing, Dangerous Road, or
POI.
Using the BCD996T with a GPS
121
Download from Www.Somanuals.com. All Manuals Search And Download.
To store your current location, press and hold [GPS] for more than 1 second. You
are prompted to enter the type of entry (Dangerous Xing, Dangerous Road, or
POI), as well as the other location parameters. When you set the beep type, you
are next prompted to set the alert volume.
The following table shows the attributes available for each category. Note that
some options are different for a specific location type. Refer to the information that
follows to set those specific attributes.
Dangerous
Xing
Dangerous
Road
Menu Option
New Location
POI
•
•
•
•
•
•
•
•
•
•
•
•
Edit Name
Set Type (edit)
Set Alert Beep
Set Alert Volume
Set Location Info
Set Heading
•
•
•
•
•
•
Set Range
•
Set Speed Limit
Set Lockout
•
•
•
•
•
•
•
•
Delete Location
Setting the Options
[MENU] ꢁꢀProgram LocationꢁF
ꢀSelect a location type (POI, Dangerous Xing, or Dangerous Road). ꢁF
ꢀNew Location ꢁF
The scanner assigns a sequentially created number to the location.
ꢀEdit Name ꢁF
Use the Scroll Control and Fto give the New Location a name. You could, for
example, enter the name of the place or the Route Number.
122
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀSet Type ꢁFAt this level you have an opportunity to reassign or edit the
location type you first selected and set the location to either one of the other types
or change the data in an existing location.
ꢀSet LocationInfo ꢁFInput the latitude and then the longitude.
ꢀSet Lockout ꢁFAs you near your target location, an alert sounds at 0.5,
0.25, and 0.1 mi. You can stop this operation by pressing [L/O]. All the data is
retained.
You can use the menu Lockoutoption as well. Set the location system to
Temporary L/Oso you can move away more than four miles and then come
back again. At that time, L/O status is automatically canceled.
If you turn off the switch, the scanner is unlocked.
For POI Only
ꢀSet Alert Beep ꢁFChoose Off sono tone sounds or one of the four
alert melodies Alert 1to Alert 4.
Once you make a Tone selection you are immediately asked to assign a volume
level to that selection.
Set Alert Volume ꢁFSelect from 15 sound levels, plus Auto and Off. As
you rotate the Scroll Control the Alert tone you set is played louder and louder.
Press Fto select a volume level. You can also select Auto, a level that is the
same setting as your master volume control.
ꢀSet Range ꢁFInput how far away the alert sounds for the site (only
available for POI’s and between .1 and 2.0 miles)
For Dangerous Xing, and Dangerous Road Only
The Alert Tone is fixed. The alert range is auto-set at .5, .25, and .1 mile.
ꢀSet Alert Volume ꢁFSelect from 15 sound levels, plus Auto and Off. As
you rotate the Scroll Control the Alert tone is played louder and louder. Press F
to select a level you want. You can also select Off (no sound) or Auto, a level
that is the same as your master volume control.
For Dangerous Xing and Dangerous Road sites there are two additional settings:
Using the BCD996T with a GPS
123
Download from Www.Somanuals.com. All Manuals Search And Download.
An Example of a POI Alert
The Uniden America Corporation is
located at 4700 Amon Carter Blvd
in Ft. Worth, TX. The Latitude and
Longitude of the front entrance is
32° 50’00.63” N and 97°02’54.16”
W.
When you program that data as a
POI, you can select alert ranges of
.1, .25, .5, .75, 1.0, 1.5, and 2.0
mile distances to the POI. Shown
on the map are .5 and 1.0 mile
markers.
You are alerted when you come
within range of your set distances.
ꢀSet Heading ꢁFYou can input the compass direction to the site from your
present location or, you can select All Rangewhich ignores your specific
heading.
For example: If the Dangerous Road location is toward the Northeast and you are
driving in that direction, then choose NE(45°)
If you know you will be driving on a road which has many curves to that site center,
choose All Rangewhich will trigger the alert regardless of direction as long as
the other requirements (range, speed) are met.
If you travel in a Northeast direction and do not travel either side of a northeast line
by up to 22 degrees, the alert system will function.
ꢀSet Speed Limit ꢁFChoose from 0, through 100 MPH in 5 MPH steps or
the equivalent in KPH for metric usage.
Deleting a Location
If you have programmed a location that you no longer want, you can delete it as
follows.
[MENU] ꢁProgram LocationꢁF
ꢀSelect a location such as Dangerous XingꢁF
124
Download from Www.Somanuals.com. All Manuals Search And Download.
The BCD996T, a GPS, and a Dangerous Road
Car One
Car One is driving south. Car Two is driving
east. Car One is alerted since the Latitude
and Longitude of the Dangerous Road is
programmed as well as the Range and the
Direction. When all three conditions are
met, the alert sounds. Since Car Two is
going east, no alert sounds.
Programmed Settings
41° 17’ 58.64” N
74°11’ 10.30” W
Car Two
Heading South
ꢀLocation to be deleted ꢁF
ꢀDelete LocationꢁF
ꢀConfirm Delete? Yes=”E” / No=”.”ꢁF
Make your choice to either delete the location or to cancel.
GPS Display Mode
Press [GPS], to switch the scanner to a GPS display mode. In this mode, you can
see location information as well as information about your position relative to the
selected POI. The third line of the screen shows Offif no POI is selected.
Rotate the Scroll Control to select different POI’s.
Press F+ [GPS] to toggle the Display mode in order.
GPS DATA Display
ETA Display
Clock Display
Elevation Display
Speed Display
Location Display
Using the BCD996T with a GPS
125
Download from Www.Somanuals.com. All Manuals Search And Download.
GPS Review Location Mode
If you have programmed data for a Point of Interest, Dangerous Crossing, and a
Dangerous Road, you can review each set on a screen dedicated to showing just
that data.
Press [EYES] in GPS Mode.
The most recent stored location is displayed. Use the Scroll Control to display the
next screen for review.
Important: While you are in normal GPS mode or Scan Mode and you press and
hold [GPS] for 2 seconds, location data at that point is stored. The scanner opens
a dialog to store your current location. The default name is T YYMMDD hhmmss
that indicates the date and time you stored the location point.
The data is put into memory and you can designate the location as POI,
Dangerous Xing, or Dangerous Road.
However, if you are in Review Mode and press and hold [GPS], the data of the
new point will overwrite the currently displayed data.
The following keys also have a different function while in GPS Review Mode.
[GPS] — Press and Hold: overwrites and stores current location data
[MENU] — returns to GPS Mode.
[L/O] — changes the status of the currently displayed location data.
[L/O] — press and hold to unlock all locations
of the current type (POI, DXG, or DRG)
Unlocked All TTTs?and Yes=”E” / No=”.”is displayed. TTTshows the
location type as POI, DXG or DRD.
[L/O] — press and hold in Function Mode unlocks all locations of all types.
Unlocked All Location?and Yes=”E” / No=”.”is displayed.
[.No] — returns to GPS Mode.
[EYES] — lets you edit a location details
[SCAN/SEARCH] — enter scan mode.
[HOLD/RESUME] — enter Scan Hold mode
F— enter Function Mode.
126
Download from Www.Somanuals.com. All Manuals Search And Download.
ꢀ— select a programmed location from all stored locations. The location data is
stored in the order POI, Dangerous Xing, and Dangerous Road. Then, in each
category, the data is stored using the programmed name.
1. POI — Indicates a Point of Interest location.
2. DXG — Indicates a Dangerous Crossing location.
3. DRD — Indicates a Dangerous Road location.
4. Range — Indicates the programmed distance to your POI.
5. Head — Indicates the selected heading to the designated Dangerous
Crossing from any direction.
6. Head — Indicates the selected heading to the designated Dangerous Road
from a set direction.
7. LS — Indicates the maximum Speed Limit you set.
Using the BCD996T with a GPS
127
Download from Www.Somanuals.com. All Manuals Search And Download.
Care and Maintenance
General Use
Turn the scanner off before disconnecting the power.
If memory is lost, simply reprogram each channel.
Always press each button firmly until you hear the entry tone for that key entry.
Location
Do not use the scanner in high-moisture environments such as the kitchen or
bathroom.
Avoid placing the unit in direct sunlight or near heating elements or vents.
If the scanner receives strong interference or electrical noise, move it or its
antenna away from the source of the noise. If possible, a higher elevation might
provide better reception.
Also try changing the height or angle of the antenna.
Cleaning
Disconnect the power to the unit before cleaning.
Clean the outside of the scanner with a mild detergent.
To prevent scratches, do not use abrasive cleaners or solvents. Be careful not to
rub the LCD window.
Do not use excessive amounts of water.
Repairs
Do not attempt any repair. The scanner contains no user serviceable parts.
Contact the Uniden Customer Service Center or take it to a qualified repair
technician.
Birdies
All radios can receive “birdies” or undesired signals. If your scanner stops during
Scan mode and no sound is heard, it might be receiving a birdie. Birdies are
internally generated signals inherent in the electronics of the scanner.
Press [L/O] to lock out the channel.
128
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
From time to time, Uniden might update the BCD996T’s firmware to change the
scanner’s performance or incorporate new features. These updates can be
applied by you using the supplied PC cable and the software that we will provide.
Please note that firmware data must be input by means of the front panel serial
cable connection, not the rear connector. We recommend you visit the Uniden web
site periodically to check for the latest updates.
However, if you believe your BCD996T is not performing properly, try these
suggestions.
Problem
Possible Cause
Suggestion
The scanner doesn’t
work.
The scanner might not be
receiving any power.
Make sure the AC adapter is connected to
an AC outlet and the scanner. The display
should light and cycle if you repeatedly
press [VOL]
If there is a wall switch that controls power
to the AC outlet where you connected the
AC adapter, make sure it is on.
Improper reception.
The antenna might need to be
adjusted.
Check the antenna connection or move or
reposition the antenna.
Move the scanner.
You might be in a remote area that could
require an optional multi-band antenna.
Check with your dealer or local electronics
store.
Scan won’t stop.
The squelch might need to be
adjusted.
Adjust the squelch threshold. See “Turning
On the Scanner and Setting the Squelch”
on Page 45.
The antenna might need to be
adjusted.
Check the antenna connection.
One or more channels might be Make sure the channels you want to scan
locked out. are not locked out.
The channel’s frequency might Make sure the channel’s frequency is
not be stored in memory.
stored in the scanner’s memory.
The channel might not be
active.
Wait for a transmission on the channel.
Troubleshooting
129
Download from Www.Somanuals.com. All Manuals Search And Download.
Problem
Possible Cause
You must press
Suggestion
Scan won’t start.
Press [SCAN/SEARCH].
[SCAN/SEARCH] to scan.
The squelch might need to be
adjusted.
Adjust the squelch threshold. See “Turning
On the Scanner and Setting the Squelch”
on Page 45.
One or more channels might be Make sure the channels you want to scan
locked out.
are not locked out.
The antenna might need to be
adjusted.
Check the antenna connection.
Weather scan doesn’t The squelch might need to be
Adjust the squelch threshold. See “Turning
On the Scanner and Setting the Squelch”
on Page 45.
work.
adjusted.
The antenna might need to be
adjusted.
Check the antenna connection.
There might not be a NOAA
weather broadcast in your
area.
Move to an area with a NOAA weather
broadcast.
If you experience difficulty while in TrunkTracker™ mode, try the following steps.
Problem
Possible Cause
Suggestion
Scanner won’t track a
trunked system.
The system might not be one
your scanner can scan.
Change to another system and try
scanning that system.
The data frequency might be
missing.
Enter the data frequency.
The scanner might need to be
changed to a Type 1 scanner
setup.
Change to a Type 1 scanner setup. See
the programming instructions on the web
at www.uniden.com/scanners.
The system you are trying to
scan might be LTR or
EDACS.
Set the scanner to scan LTR or EDACS
systems. See the programming
instructions on the web at
www.uniden.com/scanners.
No ID’s have been
programmed.
Program one or more ID’s or use the ID
Search mode.
The ID’s you have stored are
not active.
Wait for the ID’s to become active or scan
another system.
130
Download from Www.Somanuals.com. All Manuals Search And Download.
Problem
Possible Cause
Suggestion
Scanner won’t acquire
the data channel.
The squelch might need to be
adjusted.
Adjust the squelch threshold. See
“Turning On the Scanner and Setting the
Squelch” on Page 45.
The frequency used for the
data channel might be
missing.
Check your frequency list for the data
channel.
Missing replies to
conversations.
The scanner might need to be
changed to a Type 1 scanner
setup.
Change to a Type 1 scanner setup. See
the programming instructions on the web
at www.uniden.com/scanners.
The fleet map might be
incorrect.
Try another preset fleet map or program
your own fleet map.
One or more of the system’s
frequencies might not be
entered.
Make sure all the system’s frequencies
have been entered.
The system you are trying to
scan might be LTR or
EDACS.
Set the scanner to scan LTR or EDACS
systems. See the programming
instructions on the web at
www.uniden.com/scanners.
If you still cannot get satisfactory results while using your scanner or if you want
additional information, please call or write the Uniden Parts and Service Division.
The address and phone number are listed in the Warranty at the end of this
manual. If you would like immediate assistance, please call Customer Service at
(800) 297-1023.
If you have Internet access, you can visit
http://www.uniden.com for additional information.
Troubleshooting
131
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
Certificated accordance with FCC Rules and Regulations Part 15 Subpart C as of
date of manufacture.
Dynamic Allocation Capacity
Systems :
Groups :
Site :
500 max
20 per system
1000 max (All) 256 per system
up to 6000 (3000 typical)
Channels :
Channels per Trunked System : up to 250
Band Coverage :
31 Bands
Frequency Range :
Range (MHz)
25.0000 to 26.9600
26.9650 to 27.4050
27.4100 to 27.9950
28.0000 to 29.6800
29.7000 to 49.9900
50.0000 to 53.9800
54.0000 to 71.9500
72.0000 to 75.9950
76.0000 to 87.9500
88.0000 to 107.9000
108.0000 to 136.9750
137.0000 to 143.9875
144.0000 to 147.9950
148.0000 to 150.7875
150.8000 to 161.9950
162.0000 to 173.9875
174.0000 to 215.9500
216.0000 to 224.9800
225.0000 to 379.9750
380.0000 to 399.9875
400.0000 to 405.9875
406.0000 to 419.9875
420.0000 to 449.9875
450.0000 to 469.9875
470.0000 to 512.0000
Step (kHz)
Mode
AM
AM
5
5
5
20
10
20
50
5
50
100
25
12.5
5
12.5
5
12.5
50
Petroleum Prods & Bcst pickup
CB Class D Channel
Business & Forest Prods
10 Meter Amateur Band
VHF Low Band
6 Meter Amateur Band
VHF TV
Intersystem & Astronomy
VHF TV
AM
NFM
NFM
NFM
WFM
FM
WFM
FMB
AM
NFM
NFM
NFM
NFM
NFM
WFM
NFM
AM
NFM
NFM
NFM
NFM
NFM
NFM
FM Broadcast
Aircraft Band
Military Land Mobile
2 Meter Amateur Band
Military Land Mobile
VHF High Band
Federal Government
VHF TV
1.25 Meter Amateur Band
Military Aircraft Band
Military Land Mobile
Miscellaneous
Federal Government Land Mobile
70 cm Amateur Band
UHF Standard Band
UHF TV
20
25
12.5
12.5
12.5
12.5
12.5
12.5
132
Download from Www.Somanuals.com. All Manuals Search And Download.
Range (MHz)
Step (kHz)
12.5
Mode
NFM
NFM
NFM
NFM
NFM
NFM
764.0000 to 775.9875
794.0000 to 805.9875
806.0000 to 823.9875
849.0125 to 868.9875
894.0125 to 956.0000
1240.0000 to 1300.0000
Public Service Band
Public Service Band
Public Service Band
Public Service Band
Public Service Band
25 cm Amateur Band
12.5
12.5
12.5
12.5
25
Sensitivity (nominal) 12dB SINAD :
0.4µV
0.3µV
0.7µV
0.3µV
0.6µV
0.4µV
0.3µV
0.6µV
0.3µV
0.4µV
0.4µV
0.3µV
0.7µV
25 - 27.995 MHz
28 - 53.98 MHz
54 - 71.95 MHz
72 - 75.995 MHz
76 - 107.9 MHz
108 - 136.975 MHz
137 - 173.9875 MHz
174 - 215.95 MHz
216 - 224.98 MHz
225 - 379.975 MHz
380 - 512 MHz
AM
NFM
WFM
FM
WFM/FMB
AM
NFM
WFM
NFM
AM
NFM
NFM
NFM
764 - 954 MHz
1240 - 1300 MHz
Attenuation :
Scan Rate :
20dB nominal
100 channels per second (Conventional mode) max
300 steps per second (5 kHz step only) max
2.6W nominal into 8Ω speaker
Search Rate :
Audio Output :
30mW nominal into 32Ω stereo headphone:
DC 11.0V to 16.6V
Power Requirements :
AC Adapter (AD-1009) or Cigarette Lighter Cord or DC Cord
with Orange Wire
External Jacks :
Antenna Jack
Phone Jack
BNC Type
3.5mm (1/8-in.) Stereo Type
3.5mm (1/8-in.) Monaural Type
3.5mm (1/8-in.) Stereo Type
5.5mm Center Positive
Ext. Speaker Jack
REC. Out Jack
DC Power Jack
Specifications
133
Download from Www.Somanuals.com. All Manuals Search And Download.
Remote Interface Jack
4pin Mini Type
GPS / Remote Interface Jack
Ext. DC Power / ORNG Wire Jack
D-sub 9pin Male Type
3pin (Center Orange Wire)
Operating Temperature :
Nominal -20°C to +60°C
Close Call -10°C to +60°C
-4°F to +140°F
+14°F to +140°F
Size :
7.2 in. (W) x 5.9 in. (D) x 2.2 in. (H)
183mm (W) x 150mm (D) x 56mm H)
3.46 lbs [1.57 kg.] (without Mounting Bracket)
Weight :
Features, specifications, and availability of optional accessories are all subject to
change without notice.
Contact your local Uniden Dealer or call the Uniden Parts Center at:
(800) 554-3988, 8:00AM to 5:00PM EST, Monday through Friday, for information
about ordering these optional accessories.
134
Download from Www.Somanuals.com. All Manuals Search And Download.
Reference
Preset Fleet Maps
Note: Size Codes in parenthesis indicates that the Size Code spans more than
one block.
Preset Map 1
Preset Map 2
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
Size Code 11
Size Code 11
Size Code 11
Size Code 11
Size Code 11
Size Code 11
Size Code 11
Size Code 11
0
1
2
3
4
5
6
7
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Preset Map 3
Preset Map 4
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Size Code 12
(Size Code 12)
0
1
2
3
4
5
6
7
Size Code 12
(Size Code 12)
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Preset Map 5
Preset Map 6
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
Size Code 4
Size Code 4
Size Code 12
(Size Code 12)
Size Code 4
Size Code 4
Size Code 4
Size Code 4
0
1
2
3
4
5
6
7
Size Code 3
Size Code 10
Size Code 4
Size Code 4
Size Code 12
(Size Code 12)
Size Code 12
(Size Code 12)
Reference
135
Download from Www.Somanuals.com. All Manuals Search And Download.
Preset Map 7
Preset Map 8
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
Size Code 10
Size Code 10
Size Code 11
Size Code 4
Size Code 4
Size Code 4
Size Code 4
Size Code 4
0
1
2
3
4
5
6
7
Size Code 1
Size Code 1
Size Code 2
Size Code 2
Size Code 3
Size Code 3
Size Code 4
Size Code 4
Preset Map 9
Preset Map 10
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
Size Code 4
Size Code 4
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 0
0
1
2
3
4
5
6
7
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 4
Size Code 4
Preset Map 11
Preset Map 12
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
Size Code 4
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 0
0
1
2
3
4
5
6
7
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 0
Size Code 4
Preset Map 13
Preset Map 14
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
Size Code 3
Size Code 3
Size Code 11
Size Code 4
Size Code 4
Size Code 0
Size Code 0
Size Code 0
0
1
2
3
4
5
6
7
Size Code 4
Size Code 3
Size Code 10
Size Code 4
Size Code 4
Size Code 4
Size Code 12
(Size Code 12)
136
Download from Www.Somanuals.com. All Manuals Search And Download.
Preset Map 15
Preset Map 16
Block
Size Code
Block
Size Code
0
1
2
3
4
5
6
7
Size Code 4
Size Code 4
Size Code 4
Size Code 11
Size Code 11
Size Code 0
Size Code 12
(Size Code 12)
0
1
2
3
4
5
6
7
Size Code 3
Size Code 10
Size Code 10
Size Code 11
Size Code 0
Size Code 0
Size Code 12
(Size Code 12)
User Defined Fleet Maps
Type I Programming Information
When a Type I system is designed, the address information for all the ID’s is
divided into 8 equal sized blocks, numbered 0–7. When you program your scanner
to track a Type I system, you must select a size code for each of these blocks.
When you have assigned a size code to all 8 blocks, you’ll have defined the fleet
map for the system you are tracking. Each size code determines the number of
fleets, subfleets, and ID’s each block will have. For example, a size code of S-4
has one fleet, which is divided into 16 separate subfleets, and it has a total of 512
individual ID’s.
When a block is assigned a size code, the fleet or fleets created within the block
are assigned a Type I ID. The way these ID’s display on your scanner depend on
the block number and the block’s size code. When a Type I ID appears, the
leftmost digit represents the block which contains the ID.
The next 2-3 digits identify which fleet is active, and the last digit(s) identifies the
subfleet.
The details concerning how the size codes are selected by a Type I System
designer are highly dependent on the specific needs of the system’s users. Some
organizations might want many subfleets with only a few radios each, while
another organization might want only a few subfleets with many radios each. Your
task is to program your fleet map with the same size code assignments as the
trunked system. If you do this accurately, you’ll track all the Fleet-Subfleet
combinations used by the system. In other words, you’ll hear complete
communications while monitoring a trunked system.
If you don’t already know the size codes used, you’ll have to guess at them. But
since you don’t have to figure out all the blocks at once, this isn’t as hard as it
Reference
137
Download from Www.Somanuals.com. All Manuals Search And Download.
seems. Select a size code for a block, and then press Scan. Now listen to the
communications. If you decide you are receiving most of the replies to the
conversations with ID’s assigned to the block you just programmed, then you’ve
probably selected the right size code and can work on the next block of the map.
Finally, for most public safety systems there are some size codes which are more
common. S-3 and S-4 are probably the most common, followed by S-10, S-11, and
S-12.
Size Code Restrictions
If you select size code S-12, S-13, or S-14, there are some restrictions as to which
blocks can be used for these codes.
• S-12 can only be assigned to Blocks 0, 2, 4, or 6.
• S-13 can only be assigned to Blocks 0 and 4.
• S-14 can only be assigned to Block 0.
Since these size codes require multiple blocks, you will be prompted for the next
available block when programming a fleet map. For example, if you assign Block 0
as an S-12, you will be prompted for b2, the next block available, instead of b1.
And if you assign Block 0 as an S-14, you would not see another prompt because
it uses all available blocks.
138
Download from Www.Somanuals.com. All Manuals Search And Download.
Preprogrammed Systems and Lockout Options
Your scanner is preprogrammed with over 500 channels covering police, fire, and
ambulance operations in the 25 most populated counties in the US. The following
list details the preprogrammed information.
By default, only the Nationwide systems are unlocked, and your scanner begins to
scan them when you turn it on. To speed up scanning, you can lock out systems
that are beyond your reception area (typically no more than 25 miles using the
supplied antenna). Suggestion: Do not unlock all the preprogrammed sites. You
may wish to lock all the sites and unlock only those in your area by using their
Quick Key.
Follow these steps to lock out systems.
1. Press and hold F.
2. While continuing to hold F, rotate the Scroll Control to select a system you
want to lock out.
3. While continuing to hold F, press [L/O] to lock out the system.
4. Repeat Steps 2, and 3 to lock out additional systems.
The preprogrammed systems provide a starting point; you will want to find out
more information about your local radio systems so you can customize the
programming to better suit your listening preferences.
Notes:
• The list is subject to change.
• You might hear transmissions on frequencies assigned to very distant stations.
This will happen if a local system also uses the same frequency. Disregard the
text tag for these transmissions (e.g. if you are in California, you aren’t really
receiving Florida transmissions even if the scanner displays Dade County).
• To free up memory, delete systems that you will not be monitoring.
• Data used for the preprogrammed information was supplied courtesy of
http://www.radioreference.com, the Internet’s premier scanning resource
(RadioReference is not affiliated with Uniden America Corporation).
Preprogrammed Systems and Lockout Options
139
Download from Www.Somanuals.com. All Manuals Search And Download.
Preprogrammed Systems with Quick Keys
State, or City Area
Alameda, CA Area
Quick Key
24
Alaska
21
43
30
51
34
40
32
46
47
28
60
52
36
58
31
53
62
59
25
35
29
37
38
39
20
45
42
27
48
61
41
49
22
50
Albuquerque, NM Area
Atlanta, GA Area
Austin, TX Area
Boston, MA Area
Charlotte, NC Area
Chicago, IL Area
Cincinnati, OH Area
Cleveland, OH Area
Colorado
Connecticut
Dallas-Fort Worth, TX Area
Detroit, MI Area
Harrison County, WV
Houston County, GA
Houston, TX Area
Indiana
Las Vegas, NV Area
Los Angeles, CA Area
Massachusetts
Miami-Dade, FL Area
Michigan
Minnesota
Montana
Nationwide
New York City, NY Area
Newark, NJ Area
Oakland, CA Area
Ohio
Oklahoma
Omaha, NE Area
Philadelphia, PA Area
Phoenix, AZ Area
Pittsburgh, PA Area
140
Download from Www.Somanuals.com. All Manuals Search And Download.
State, or City Area
Quick Key
San Antonio, TX Area
54
San Diego, CA Area
Santa Fe, NM Area
Seattle, WA Area
South Texas
26
44
57
55
33
23
56
St. Clair County, IL
Tucson, AZ Area
Virginia
CTCSS Frequencies
67.0
82.5
69.3
85.4
71.9
88.5
74.4
91.5
77.0
94.8
79.7
97.4
100.0 103.5 107.2 110.9 114.8 118.8
123.0 127.3 131.8 136.5 141.3 146.2
151.4 156.7 159.8 162.2 165.5 167.9
171.3 173.8 177.3 179.9 183.5 186.2
189.9 192.8 196.6 199.5 203.5 206.5
210.7 218.1 225.7 229.1 233.6 241.8
250.3 254.1
DCS Codes
023 025 026 031 032 036 043 047
051 053 054 065 071 072 073 074
114 115 116 122 125 131 132 134
143 145 152 155 156 162 165 172
174 205 212 223 225 226 243 244
245 246 251 252 255 261 263 265
266 271 274 306 311 315 325 331
332 343 346 351 356 364 365 371
411 412 413 423 431 432 445 446
452 454 455 462 464 465 466 503
Preprogrammed Systems with Quick Keys
141
Download from Www.Somanuals.com. All Manuals Search And Download.
506 516 523 526 532 546 565 606
612 624 627 631 632 654 662 664
703 712 723 731 732 734 743 754
142
Download from Www.Somanuals.com. All Manuals Search And Download.
Index
A
Delay 70
Delete 85
Deleting 91
Alert
Channel 13
Display Mode 51
Editing 75
Found, Saving 99
Group 16, 21
Group Name 44
Holding 49
Custom 13
Dangerous Xing-Road 123
Duplicate Frequency 14
Emergency 73
GPS 15
POI 124
Lock/Unlock 48, 84
Lockout 13
Logical Number 26
Marked 33
Memory 12
Modulation 88
Priority 89
Setting Channel 90
Weather 15, 113
Antenna 19, 31, 33, 37
APCO 14, 15, 24, 26, 40, 52, 87, 111
Attentuator, Attenuation
13, 44, 79, 89, 98,109
Auto Store 16, 99, 101, 102, 108
Programming 83
Single Autonomous 27
Step 14
System 47
Tone-Out 118
B
Backlight 14,35, 55, 56
Band Plan 80-81
Beep 26
Close Call
Alert 73, 123
Close Call 102
Key 56
DND 102
Feature 12
Hits with Scan 103
Options 105
Setting 101
Using 101
Birdies 14, 128
Broadcast 13
Broadcast Screen 106
C
Contrast 57
Conventional
Auto Store 16
Channel
Add CTCSS/DCS 87
Alert 13
Feature 14
Programming 66
Scanning 23
Search and Store 99
Startup Options 45
System 52
All 33
Attenuation 89
Control 15, 25, 26
Control Mode 81
Copying 91
Creating 85
CTCSS/DCS 15
Copy
Channels 91
Systems 76
Index
143
Download from Www.Somanuals.com. All Manuals Search And Download.
CTCSS
Display Indicator 44
Channels 84
Custom Search Range 95
Frequencies 86
Service Search 97
Sites 75
System Quick Key 68
Talk Group ID 86
Frequencies 141
Quick Save 88
Selecting 87
What is 22
D
End Code 72
Dangerous Xing, Road
Deleting Location 124
Option Setting 122
Review Mode 126
Road 121
F
Fleet 26, 27, 71, 135, 137
G
Screens 127
Settings 123
Xing 121
GPS
Compatible 119
Connecting 119
Data
Distance Units 58
Features 15
Alpha 99
Channel 51
Download 60
GPS 58
LCN 26
Programming 16
SCAT 27
Initial Operation 119
Location Based Scanning 120
Location Information 71
Non-Location Based 121
Position Format 57
Saving Longitude/Latitude 99
Setting Format 57
Time Format 58
Setting Skip 109
Skip 14, 70
Talk Group 26
Transfer 60
Time Zone 58
Using the Scanner 119
Dimmer 14, 35, 55
DIN-E 31, 34, 36
I
I-Call
E
Feature 29
Edit
Operations 72
ID Scan 48, 49, 70
Indicators 44, 47, 50
ISO 31, 36, 37
Channel Data 43
Menu 43
System 62
System Name 67
Tone Out 43
Editing
L
Lockout
Band Plan 80
Channel Groups 75
Channel Name 85
Automatic 121
Channel Groups 84
Custom Search Range 96
144
Download from Www.Somanuals.com. All Manuals Search And Download.
Options 139
Search Limits 17
Setting 91
Sites 79, 120
Systems 69
Port 58, 61
Preprogrammed 12, 15, 19, 47, 62, 93,
113, 139, 140
Preset
Edit Maps 71
Fleet Maps 135
Search Ranges 94
R
LTR
Display 84
ID 27
LCN 78
Range
Scan Time 80
Site Limit 76
Trunking 27
All 124
Display 127
Edit 95
GPS 15
Search 22, 45, 94, 98
Set 71
M
Menu 17
Entering Text 18
Using 18, 54
Motorola
S
Scan
Band Plan 80
Control Channel 82
Edit System Names 67
Emergency Alert Options 73
End Code 72
Close Call Hits 103
Control Channel Only 15
Conventional 23
Function 17
ID 48
Fleet Maps 71
Legally 9
I-Call 29
Specifying System Type 68
Status Bit 72
Trunking 25
Types 26
Priority 16, 111
Search Delay 13
Search With 13, 96
Selecting Systems 47
Systems 46
Multi-Site 14, 28
Trunked 25
Understanding 21
What is 22
N
NOAA 113, 115
SCAT 14, 26, 27, 76, 80, 84, 100
Search
P
Assigning a Range to
a Search Key 98
Auto and Store 99
Close Call Options 105
Conventional 99
Custom 94
Edit a Service 97
Edit Custom Range 95
Feature 12, 15
POI
Display 127
Distance 58
Example 124
Location, Range 121
Lock, Unlock 126
Only For 123
Setting 122
Index
145
Download from Www.Somanuals.com. All Manuals Search And Download.
Frequency Step 110
ID 48
Lockout Limits 17
Quick 94
Range 45
Reviewing ID Lockouts 74
Scan Delay 13
Service 93
Store ID 49
Trunked and Store 100
Weather 15
What Is 22
Squelch 13, 22, 45, 60
Subfleet 26-27, 137
W
Weather
Alert Priority 115
Features 15
SAME Alert 15
Searching 113
Turning on Alert 114
146
Download from Www.Somanuals.com. All Manuals Search And Download.
One-Year Limited Warranty
Important: Evidence of original purchase is required for warranty service.
WARRANTOR: UNIDEN AMERICA
CORPORATION (“Uniden”)
ELEMENTS OF WARRANTY: Uniden warrants, for one year, to the original retail
owner, this Uniden Product to be free from defects in materials and craftsmanship
with only the limitations or exclusions set out below.
WARRANTY DURATION: This warranty to the original user shall terminate and be
of no further effect 12 months after the date of original retail sale. The warranty is
invalid if the Product is (A) damaged or not maintained as reasonable or
necessary, (B) modified, altered, or used as part of any conversion kits,
subassemblies, or any configurations not sold by Uniden, (C) improperly installed,
(D) serviced or repaired by someone other than an authorized Uniden service
center for a defect or malfunction covered by this warranty, (E) used in any
conjunction with equipment or parts or as part of any system not manufactured by
Uniden, or (F) installed or programmed by anyone other than as detailed by the
Operating Guide for this product.
STATEMENT OF REMEDY: In the event that the product does not conform to this
warranty at any time while this warranty is in effect, warrantor will repair the defect
and return it to you without charge for parts, service, or any other cost (except
shipping and handling) incurred by warrantor or its representatives in connection
with the performance of this warranty. THE LIMITED WARRANTY SET FORTH
ABOVE IS THE SOLE AND ENTIRE WARRANTY PERTAINING TO THE
PRODUCT AND IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES OF
ANY NATURE WHATSOEVER, WHETHER EXPRESS, IMPLIED OR ARISING
BY OPERATION OF LAW, INCLUDING, BUT NOT LIMITED TO ANY IMPLIED
WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE. THIS WARRANTY DOES NOT COVER OR PROVIDE FOR THE
REIMBURSEMENT OR PAYMENT OF INCIDENTAL OR CONSEQUENTIAL
DAMAGES. Some states do not allow this exclusion or limitation of incidental or
consequential damages so the above limitation or exclusion might not apply to
you.
LEGAL REMEDIES: This warranty gives you specific legal rights, and you might
also have other rights which vary from state to state. This warranty is void outside
the United States of America.
PROCEDURE FOR OBTAINING PERFORMANCE OF WARRANTY: If, after
following the instructions in this Operating Guide you are certain that the Product is
One-Year Limited Warranty
147
Download from Www.Somanuals.com. All Manuals Search And Download.
defective, pack the Product carefully (preferably in its original packaging). Include
evidence of original purchase and a note describing the defect that has caused
you to return it. The Product should be shipped freight prepaid, by traceable
means, or delivered, to warrantor at:
Uniden America Corporation
Parts and Service Division
4700 Amon Carter Boulevard
Fort Worth, TX 76155
(800) 297-1023, 8:00 a.m. to 5:00 p.m., Central, Monday through Friday
148
Download from Www.Somanuals.com. All Manuals Search And Download.
MEMO
MEMO
149
Download from Www.Somanuals.com. All Manuals Search And Download.
MEMO
150
Download from Www.Somanuals.com. All Manuals Search And Download.
MEMO
MEMO
151
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
|