Ultratec Smoker LSX Low smoke converter User Manual

LSX Low Smoke Converter  
Operator’s Manual  
VER. 30.10.10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Congratulations on your purchase of a Ultratec Special Effects LSX MKII Low Smoke Convertor. With basic care,  
your LSX will provide years of trouble-free performance. The LSX is a product of many years of research and  
development resulting in a machine with many fine features and exceptional reliability.  
This manual contains detailed information on the operation of your LSX. Please take a few moments to read it  
over carefully before use, and keep it handy for your reference.  
Warning  
Important Safety Instructions:  
1. Do not touch, place hands or expose skin within 20” (50 cm) of the discharge nozzle.  
2. Do not remove the outer case.  
3. Persons suffering from asthma or allergenic sensitivity may experience irritation, discomfort or allergic  
symptoms when exposed to fog effects.  
4. Ensure that this unit is grounded at all times. Failure to do so may result in serious injury.  
5. Use Ultratec Special Effects fluid ONLY.  
Safety Precautions  
1. Ensure that any operation of the machine is supervised by suitably trained and authorized personnel.  
2. Do not modify the machine or use a machine which has been damaged in any way.  
3. Allow sufficient air circulation around the machine at all times.  
4. Protect the machine from direct weather effects and wet locations.  
5. Only use fluids manufactured by Ultratec Special Effects.  
6. Do not continue to produce fog when visibility is reduced to 20” 50cm or below.  
7. Avoid directing fog output continuously at people, structures or objects within close proximity of the discharge  
nozzle.  
8. Ensure that adequate exhausting arrangements are available in the event of an emergency.  
9. Do not place hands or exposed skin within the first 20” (50 cm) of the discharge nozzle at any time during fog  
production.  
10.Fog effects can trigger smoke alarms and detectors. Please take suitable precautions to prevent false alarms.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Technical Specifications  
Model:  
LSX Low Smoke Converter  
Part Number:  
CLF 2930 - 120 volt  
CLF 2915 - 240 volt  
Length:  
59in  
150cm  
75cm  
71cm  
68kg  
Width:  
29.5in  
28in  
Height:  
Net Weight:  
150lbs  
Power Rating:  
Fluid:  
120 Volt A.C. 50/60 Hz. 12 Amps.  
240 Volt A.C. 50/60 Hz. 6 Amps.  
Ultratec Special Effects Water Base Fog Fluid  
Technical Drawings  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Procedure  
1. During use this machine generates condensation. After use the LSX should be drained via the drain valve.  
CAUTION: This may cause the floor to become very slippery. This may also inhibit the performance of the LSX unit.  
2. This unit requires a 15 amp circuit to run properly. The use of any extension cords or shared circuit is strongly not  
recommended.  
3. It is essential that Ultratec Special Effectss Genuine Molecular Fluid is used in the Fog Machine to achieve optimum  
effect.  
4. The LSX unit is controlled by a user-friendly panel. When the system switch is in the ‘On’ position and illuminated,  
power is established to the LSX unit. A ‘green led’ is provided to indicate the compressor is operating.  
5. An Automatic Reset Low Pressure Switch is provided as protection against compressor damage. If the Low Pressure  
Switch has been activated the ‘Red’ LED will illuminate (the ‘Green’ LED will not be illuminated).  
6. The Variable Fan Control regulates Fog Density Output. Some experimenting will produce various effects. An OFF  
position is provided on this control. It is not recommended that this control be left in the off position as this will  
eventually result in activation of the Low Pressure Switch and cause a freeze up condition.  
Control Panel Operations  
1. Fan Knob: this controls the speed of the lower fan.  
Turning clockwise reduces the speed. Off is at the  
counter clockwise end.  
Note: It is not recommended to leave the control left  
in the ‘Off’ position or in a very low setting, the low  
pressure switch may activate turning off the compressor.  
2. Low Pressure Light: when lit, indicates that Low Pressure  
1
2
3
Protection has been activated. The Low Pressure Switch  
will automatically reset but may take 2 - 3 cycles to start,  
unless a leak has occurred in the system.  
3. Compressor Light: compressor is operating normal when  
lit.  
4. Power Switch: power is on when lit.  
Note: A cooler ambient temperature may result in  
activation of Low Pressure Switch within a short period  
of time after initial start up. To remedy this problem the  
unit can be stored in a warm location, a “load” can be  
put on the cooling chamber by introducing warm fog  
into the unit just after start up, or by simply covering the  
top of the unit to stop air flow.  
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before Requesting Service  
If LSX will not Power Up  
Check Power source and connections  
Green ‘LED’ is not illuminated & Red ‘LED’ is  
illuminated  
Low Pressure Switch has tripped, allow for Auto Reset  
Low Pressure Switch will not Auto Rest. Red ‘LED’ Low Refridgerant Charge (Contact Local Dealer)  
remains illuminated  
Fog will not remain on ground  
1. Ensure the use of Ultratec Special Effects Fluid  
2. Check digital temperature display reading for coil  
temperature  
3. Check Green and Red ‘LED’ see above  
Green ‘LED’ goes out when unit is operating and  
Red ‘LED’ doesn’t illuminate  
Check Power Source for sufficient voltage. Do NOT use  
extension cords.  
Condensation on floor / Floor seems slippery  
4. Too much fog going through LSX  
5. Fog machine nozzel is too close to LSX  
6. Reduce fog output, or duration  
Recommended Fluids  
Molecular Fog Fluid: A faster dissipation versus the Directors Choice Fog Fluid. This thick, clean, white fog is an  
optimal solution for a dense low-lying fog effect when chilled with the LSG or LSX machines.  
Maintenance Fluid  
EZ Kleen Preventative Maintenance Fluid: Using EZ Kleen preventative maintenance fluid on a regular basis ensures  
longer life for the heat exchanger in Ultratec fog machines by reducing blockage.  
All of our Fog Fluids are water based. Damage will occur if Haze Fluid is used.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
Warranty:  
All warranty is for one year parts and labour unless specified or manufacturer defect only.  
Abuse or Poor Maintenance will not be covered under warranty. Ultratec Special Effects Fluids  
must always be used. Use of any non Ultratec Special Effects Fluids will void all warranties.  
Accept no substitutions as there are no exceptions to this rule. Proof of Purchase or Proof of  
Sale must always accompany any warranty returns. An RA (return authorization) number must  
be noted on the outside of the box being returned to our facilities. Any packages without  
a clearly marked RA number will not be accepted by our receiving department. Freight on  
warranty items are freight prepaid to our facility and we will prepay freight back to your facility  
after repair by the most economical means available. Should you require the item express-  
returned, then you are responsible for any difference in freight cost.  
Return Policy:  
Return of any product must be done within 30 days of purchase. The package must be  
returned freight prepaid and the RA number clearly marked on the outside of the box.  
Minimum restocking fee is 25%. Once our facility has received the product a technical  
assessment will be completed to determine if an additional restocking fee needs to be issued.  
Only credits are issued to the dealers account. Any product not returned within 30 days is  
considered purchased.  
Warning:  
Ultratec Special Effects Inc. considers all of its product to be safe for use in the application it  
was intended. Ultratec Special Effects takes no responsibility for misuse or incorrect use. Always  
refer to the Product Manual for proper use.  
Contact Information  
Head Office  
Canadian Shipping Address  
USA Shipping Address  
(For All USA Repairs)  
Ultratec Special Effects Inc.  
640 Gadson St.  
Ultratec Special Effects Inc.  
1960 Blue Heron Drive  
London, Ontario N6H 5L9  
(For All Canadian Repairs)  
Ultratec Special Effects Inc.  
1960 Blue Heron Drive  
London, Ontario N6H 5L9  
Groveland, Florida 34736  
Direct: 519-659-7972  
Toll Free: 866-534-5557  
Fax: 519-659-7713  
Please remember to include the RA Number on all items being shipped for  
repairs.  
To get an RA Number, visit www.ultratecfx.com and click on the “Service” tab  
and then click on “Master Service Tracker or contact service at 519-951-3357 /  
866.534.5557  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

Targus Mouse AMB04 User Manual
Topfield Car Satellite Radio System HV7700 HSCI User Manual
Toshiba Printer B 470 QQ Series User Manual
Transcend Information Network Card TS80GSJ25 User Manual
TRENDnet Network Card TE100 P11 User Manual
Tripp Lite Surge Protector SUPER6TEL12 User Manual
UNICOM Electric Network Card ETP 20028T User Manual
Uniden GPS Receiver TRAX430 User Manual
Vizio Flat Panel Television VW42L User Manual
VuPoint Solutions Scanner PDSBT ST43 VP User Manual