Uninterrupted
Power Supply (UPS)
The Ultimate Power Protection!
If you're looking for the most complete, technologically advanced power protection
unit for the money, the Ultra UPS line is exactly what you need. An Ultra UPS is an
absolute must for anyone running a small server, workstation or a powerful PC. We're
so confident that our UPS will offer you ultimate power protection, it carries a
$125,000 guarantee against damage to any equipment connected to the UPS. You
simply cannot afford to cut corners when it comes to safeguarding your valuable
equipment, and these UPS's deliver the comprehensive protection for computer,
peripherals and data files at a remarkably low price.
Includes
Features
UPS Monitoring
- AVR (Automatic Voltage Regulation)
- Fully Digitized Microprocessor Controlled
- Protects up to 4 Devices at Once
- Energy Saving Function (UPS Green Mode)
- 50/60Hz Frequency Auto Sensing and Selection
- USB Communication Port
Software
- Advanced Battery Management (ABM Technology)
300VA
500VA
700VA
850VA
Gneral
Output
Sku
ULT33061
ULT33062
ULT33063
ULT33064
Backup Time
4-6 minutes (a PC with 15” CRT monitor)
8-12 minutes (a PC with 15” LCD monitor)
1.9(4.2)
No
150
300VA
Style A UPSx3, Bypassx3
Simulated sine wave at 120V +/- 5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
AC Mode: If load exceeds 110% of nominal, Buzzer
beeps continuously.
7-9 minutes (a PC with 15” CRT monitor)
14-16 minutes (a PC with 15” LCD monitor)
2.58(5.67)
No
250
500VA
Style A UPSx3, Bypassx3
Simulated sine wave at 120V +/- 5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
AC Mode: If load exceeds 110% of nominal, Buzzer
9-11 minutes (a PC with 15” CRT monitor)
17-19 minutes (a PC with 15” LCD monitor)
2.58(5.67)
No
350
700VA
Style A UPSx3, Bypassx3
Simulated sine wave at 120V +/- 5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
AC Mode: If load exceeds 110% of nominal, Buzzer
16-20 minutes (a PC with 15” CRT monitor)
36-40 minutes (a PC with 15” LCD monitor)
4.1(9.1)
No
425
850VA
Style A UPSx4, Bypassx4
Simulated sine wave at 120V +/- 5%
50 or 60Hz +/- 0.3Hz
2-4 milliseconds, including detection time
120V +15%/-20% at line input
50 or 60Hz +/- 10% (auto sensing)
Circuit breaker for overload & short circuit protection
AC Mode: If load exceeds 110% of nominal, Buzzer
Net Weight Kg (lbs)
Digital Display
Watts
UPS Capacity
No. of Sockets
Voltage (Battery)
Frequency (Battery)
Transfer Time
Voltage (Single Phase)
Frequency
Input
Protection
Unit Input
Overload Protection
beeps continuously. If load exceeds 120% of nominal for beeps continuously. If load exceeds 120% of nominal for beeps continuously. If load exceeds 120% of nominal for
Backup Mode: If load exceeds 110% of nominal for 1
second, UPS shuts down automatically.
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
30 seconds, 130% for 3 seconds, UPS shuts down
automatically.
Back up Mode: If load exceeds 105% of nominal for 20 Back up Mode: If load exceeds 105% of nominal for 20 Back up Mode: If load exceeds 105% of nominal for 20
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.
UPS output shuts off immediately
1140 Joules, 2ms
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.
UPS output shuts off immediately
1140 Joules, 2ms
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
seconds, 120% for 10 seconds, 130% for 3 seconds,
UPS shuts down automatically.
UPS output shuts off immediately
1520 Joules, 2ms
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
6 hours (to 90% of full capacity)
Short Circuit
Surge Protection
Type
UPS output shuts off immediately
1140 Joules, 2ms
Sealed, maintenance-free lead acid battery, with 3-6
years typical lifetime
Battery
Typical Recharge Time 4 hours (to 90% of full capacity)
Protection
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Automatic self-test, Over discharge protection, short
circuit protection by fuse
Interface
Alarm
USB
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continuous beeping sound
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continuous beeping sound
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continuous beeping sound
Battery low detecting, UPS on/off scheduling AC
input/output power status display.
Slow beeping sound every 4 seconds
Rapid beeping sound every second
AC Mode: Rapid beeping sound every 0.5 second
Continuous beeping sound
Battery Backup
Battery Low
Abnormal Charge
Overload
Environment Ambient Operation
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
<40dBA (1 meter from surface)
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
<40dBA (1 meter from surface)
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
<40dBA (1 meter from surface)
3,500 meters max. elevation, 0-95% humidity non-
condensing, 0-40?
<40dBA (1 meter from surface)
Audible Noise
1-800-830-0051