Twin Star International Indoor Fireplace 33EB304GRS User Manual |
BUILT IN ELECTRIC FIREPLACE
INSTALLATION GUIDE
MODEL NUMBERS:
33EB304GRS
39EB364GRS
CONSUMER SAFETY INFORMATION
PLEASE READ THIS MANUAL BEFORE INSTALLING THIS APPLIANCE
WARNING
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED,
AN ELECTRIC SHOCK OR FIRE MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE
VAPORS AND LIQUIDS IN THE VICINITY OF THIS
OR ANY OTHER APPLIANCE.
Thank you and congratulations on your purchase of a Classic Flame fireplace.
Please read the installation instructions before installing and operating
this appliance.
IMPORTANT: Read all instructions and warnings carefully before starting installation.
Failure to follow these instructions may result in a possible electric shock, fire
hazard and/or injury and will void the warranty.
For Customer Service:
E-Mail: [email protected]
In English Call: 866-661-1218
En Français Call: 866-374-9203
En Español Call: 866-611-1218
Twin-Star International, Inc.
Delray Beach, FL 33483
E-1
Made in China
Printed in China
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 1: Framing
Four mounting flanges on the sides of the unit
This fireplace is a zero clearance design. No
combustibles can be placed on the top
surface of the fireplace. Combustibles may
be installed to the edge of the unit.
are provided to facilitate installation.
Insulation and vapor barrier should be placed
a minimum of 2 inches from the unit.
MODEL
A
B
C
D
E
F
G
H
I
J
K
L
M
33EB304AAS 15.0”
33EB364GRS 16.0”
33.0”
39.0”
29”
33”
28.5”
32.7”
23.0”
27.2”
32.8”
38.7”
29.6”
36.0”
18.25” 23.6”
22.0” 27.6”
14.3”
15.3”
48.0”
55.0”
28.0”
34.0”
28.0”
34.0”
Framing Specifications: Figure 1
L
H
E
D
M
I
K
G
F
J
Section 2: Recommended Power Supply Wire Specifications
For 120 volt installations use two conductor,
non-metallic sheath cable with ground wire
(3 wires total) for the incoming power supply
on fireplace inserts. Use the appropriate wire
to meet local and national electrical codes for
rated power consumption.
Two conductor, non-metallic sheath cable with
ground wire (3 wires total) is recommended
for installation of a wall mounted thermostat
for use on fireplace inserts.
Recommended Wire and
Fusing Requirements
For 208/240 volt installations use three
conductor, non-metallic sheath cable with
ground wire (4 wires total) for the incoming
power supply on fireplace inserts. Use the
appropriate wire to meet local and national
electrical codes for rated power consumption.
Use appropriate wire to meet local and
national electrical codes for rated power con-
sumption. All wire gauges should be
12 gauge with a dedicated 15 amp breaker.
E-3
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3: Voltage Selector Switch Location
Important:
Caution:
Ensure that the incoming power supply
voltage matches the setting of the
voltage selector switch!!!!!!
When changing the voltage selector switch
from 240 volts to 120 volts ensure that the
power supply is turned off.
The voltage selector switch is located inside
the exhaust panel on the top left hand
corner. Carefully insert a flat headed screw-
driver inside the exhaust panel through the
hole in the mesh to change the switch from
240 volts (230 position) to 120 volts (115
position). The unit ships with the switch in the
115v position.
When wiring the unit for 208/240 volts the
voltage selector switch should be in the 230
volt position. (see figure 2)
When wiring the unit for 120 volts the voltage
selector switch should be in the 115 volt
position. (see figure 2)
Voltage Selector Switch: Figure 2
E-4
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 4: Mounting Flanges
There are two mounting flanges located on
each side of the fireplace insert. Bend tabs
accordingly and mount to framing using
suitable hardware.
Mounting Flange Location: Figure 3
Wall and Mounting Flange: Figure 4
STUD
WOOD OR METAL
MOUNTING FLANGE
K
TROC
/ SHEE
ALL
YW
DR
C
I
CERAM
TILE
Mounting Tolerances - Top View: Figure 5
MOUNTING FLANGE
INSERT
TOP
STUD
VIEW
FRONT
9/16”
3/8”
DRYWALL / SHEETROCK
CERAMIC TILE
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 5: 120 Volt Installation Instructions
Important
• The unit is factory configured for 120 volt
operation.
• All wiring must be completed prior to
installing the unit.
• Use 2 conductor wire with ground (3 wires • Ensure that the voltage selector switch is
total) from the power supply (breaker
panel) to the junction box on the unit.
in the proper position for the required
supply voltage prior to connecting the unit
to the power supply.
1. Locate the voltage selector switch inside
the exhaust panel on the top left hand
corner of the unit. (see figure 2 on page 3)
2. Confirm the switch is set to 120 volt
configuration ( 115 volt is printed on
switch).
3. Loosen the screw securing the junction
box cover and remove the cover.
4. Remove the knockouts (if necessary)
or use a cable clamp (not provided).
5. Pull out the four wires marked L1, L2,
N, and G.
6. Connect the black L1 wire from the unit to
the black L1 from the power supply.
7. Connect the red L2 wire and the N wire
from the unit to the N wire from the
power supply.
JUNCTION BOX
8. Connect the green ground wire from the
unit to the ground from the power supply.
9. Ensure that all connections are tight.
10. Insert all the wiring back into the unit and
secure with a cable clamp.
Junction Box Locator: Figure 6
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Wire Connection Diagram: Figure 7
N - WHITE WIRE
N- WHITE WIRE
120 VOLT
POWER SUPPLY
L2 - RED WIRE
BREAKER
PANEL
L1 - BLACK WIRE
G - GREEN WIRE
L1- BLACK WIRE
G- GREEN WIRE
E-7
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 6: 240 Volt Installation Instructions
Important
• The unit is factory configured for 120 volt
• All wiring must be completed prior to
installing the unit.
operation. You must set the voltage
selection switch to 240 volts (230 volt is
printed on the switch.
• Use 3 conductor wire with ground (4 wires • Ensure that the voltage selector switch is
total) from the power supply (breaker
panel) to the junction box on the unit.
in the proper position for the required
supply voltage prior to connecting the unit
to the power supply.
1. Locate the voltage selector switch inside
the exhaust panel on the top left hand
corner of the unit. (see figure 2 on page 3)
2. Confirm the switch is set to 240 volt
configuration (230 volt is printed
on switch).
3. Loosen the screw securing the junction
box cover and remove the cover.
4. Remove the knockouts (if necessary) or
use a cable clamp (not provided).
5. Pull out the four wires marked L1, L2,
N, and G.
6. Connect the black L1 wire from the unit to
the black L1 from the power supply.
7. Connect the red L2 wire from the unit to
the red L2 from the power supply.
8. Connect the white N wire from the unit to
the white N wire from the power supply.
JUNCTION BOX
9. Connect the green ground wire from the
unit to the ground from the power supply.
10. Ensure that all connections are tight.
11. Insert all the wiring back into the unit and
secure with a cable clamp.
Junction Box Locator: Figure 8
E-8
Download from Www.Somanuals.com. All Manuals Search And Download.
Wire Connection Diagram: Figure 9
N- WHITE WIRE
L2 - RED WIRE
N - WHITE WIRE
L2 - RED WIRE
240 VOLT
POWER SUPPLY
BREAKER
PANEL
L1- BLACK WIRE
G- GREEN WIRE
L1 - BLACK WIRE
G - GREEN WIRE
E-9
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 7: Wall Mounted Thermostat Wiring For 120/240 Volt
ATTENTION
• Install main power connection with
• Wiring of the thermostat must be
completed prior to the mounting of
the unit.
appropriate voltage as per Section C
or Section D.
• Install a 2 conductor wire with ground
(3 wires total) from the thermostat wall
box to the junction box on the unit.
• The following installation instructions are
for a single pole thermostat.
1. Loosen the screw securing the junction
box and remove the cover.
10. Connect the other end of the green
(ground) wire from the thermostat wall
box to the back plate of the wall mounted
thermostat with a ground screw.
2. Remove the knockouts (if necessary) or
use the provided cable clamp.
11. Ensure that all connections are tight.
3. Pull out the three wires marked T1, T2,
and TG. (red, red, and green)
12. Insert all the wiring of the wall mounted
thermostat into the wall box.
4. Remove the wire connector and separate
the wires marked T1 & T2.
13. Insert all the wiring back into the unit and
secure with a cable clamp.
5. Connect the (red) T1 wire from the unit
to the white (neutral) wire from the wall
thermostat box by using a wire connector.
(not supplied)
6. Connect the other end of the white
(neutral) wire from the thermostat wall
box to the red wire from the wall
thermostat.
7. Connect the (red) T2 wire from the unit to
the black wire from the thermostat wall
box by using a wire connector.
(not supplied)
JUNCTION BOX
8. Connect the other end of the black wire
from the thermostat wall box to the black
wire from the wall thermostat.
9. Connect the green (ground) TG wire from
the unit to the green (ground) wire from
the thermostat wall box by using a wire
connector. (not supplied)
Junction Box Locator: Figure 10
E-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Wire Connection Diagram: Figure 11
2 CONDUCTOR WIRE FROM WALL THERMOSTAT
T 2 - RED WIRE
MECHANICAL
T 1 - RED WIRE
LINE VOLTAGE
THERMOSTAT
WALL MOUNTED
T G - GREEN WIRE
E-11
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 8: Wiring Schematic - Bottom Section & PCB
E-12
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 9: Wiring Schematic - Heater
E-13
Download from Www.Somanuals.com. All Manuals Search And Download.
A Division of Twin-Star International, Inc.
115 S.E. 4th Avenue • Delray Beach, Florida 33483
Phone: 561-330-3201 • Fax: 561-330-3205
E-14