BUILT IN ELECTRIC FIREPLACE  
INSTALLATION GUIDE  
MODEL NUMBERS:  
33EB304GRS  
39EB364GRS  
CONSUMER SAFETY INFORMATION  
PLEASE READ THIS MANUAL BEFORE INSTALLING THIS APPLIANCE  
WARNING  
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED,  
AN ELECTRIC SHOCK OR FIRE MAY RESULT CAUSING  
PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.  
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE  
VAPORS AND LIQUIDS IN THE VICINITY OF THIS  
OR ANY OTHER APPLIANCE.  
Thank you and congratulations on your purchase of a Classic Flame fireplace.  
Please read the installation instructions before installing and operating  
this appliance.  
IMPORTANT: Read all instructions and warnings carefully before starting installation.  
Failure to follow these instructions may result in a possible electric shock, fire  
hazard and/or injury and will void the warranty.  
For Customer Service:  
In English Call: 866-661-1218  
En Français Call: 866-374-9203  
En Español Call: 866-611-1218  
Twin-Star International, Inc.  
Delray Beach, FL 33483  
E-1  
Made in China  
Printed in China  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 1: Framing  
Four mounting flanges on the sides of the unit  
This fireplace is a zero clearance design. No  
combustibles can be placed on the top  
surface of the fireplace. Combustibles may  
be installed to the edge of the unit.  
are provided to facilitate installation.  
Insulation and vapor barrier should be placed  
a minimum of 2 inches from the unit.  
MODEL  
A
B
C
D
E
F
G
H
I
J
K
L
M
33EB304AAS 15.0”  
33EB364GRS 16.0”  
33.0”  
39.0”  
29”  
33”  
28.5”  
32.7”  
23.0”  
27.2”  
32.8”  
38.7”  
29.6”  
36.0”  
18.25” 23.6”  
22.0” 27.6”  
14.3”  
15.3”  
48.0”  
55.0”  
28.0”  
34.0”  
28.0”  
34.0”  
Framing Specifications: Figure 1  
L
H
E
D
M
I
K
G
F
J
Section 2: Recommended Power Supply Wire Specifications  
For 120 volt installations use two conductor,  
non-metallic sheath cable with ground wire  
(3 wires total) for the incoming power supply  
on fireplace inserts. Use the appropriate wire  
to meet local and national electrical codes for  
rated power consumption.  
Two conductor, non-metallic sheath cable with  
ground wire (3 wires total) is recommended  
for installation of a wall mounted thermostat  
for use on fireplace inserts.  
Recommended Wire and  
Fusing Requirements  
For 208/240 volt installations use three  
conductor, non-metallic sheath cable with  
ground wire (4 wires total) for the incoming  
power supply on fireplace inserts. Use the  
appropriate wire to meet local and national  
electrical codes for rated power consumption.  
Use appropriate wire to meet local and  
national electrical codes for rated power con-  
sumption. All wire gauges should be  
12 gauge with a dedicated 15 amp breaker.  
E-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 3: Voltage Selector Switch Location  
Important:  
Caution:  
Ensure that the incoming power supply  
voltage matches the setting of the  
voltage selector switch!!!!!!  
When changing the voltage selector switch  
from 240 volts to 120 volts ensure that the  
power supply is turned off.  
The voltage selector switch is located inside  
the exhaust panel on the top left hand  
corner. Carefully insert a flat headed screw-  
driver inside the exhaust panel through the  
hole in the mesh to change the switch from  
240 volts (230 position) to 120 volts (115  
position). The unit ships with the switch in the  
115v position.  
When wiring the unit for 208/240 volts the  
voltage selector switch should be in the 230  
volt position. (see figure 2)  
When wiring the unit for 120 volts the voltage  
selector switch should be in the 115 volt  
position. (see figure 2)  
Voltage Selector Switch: Figure 2  
E-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 4: Mounting Flanges  
There are two mounting flanges located on  
each side of the fireplace insert. Bend tabs  
accordingly and mount to framing using  
suitable hardware.  
Mounting Flange Location: Figure 3  
Wall and Mounting Flange: Figure 4  
STUD  
WOOD OR METAL  
MOUNTING FLANGE  
K
TROC  
/ SHEE  
ALL  
YW  
DR  
C
I
CERAM  
TILE  
Mounting Tolerances - Top View: Figure 5  
MOUNTING FLANGE  
INSERT  
TOP  
STUD  
VIEW  
FRONT  
9/16”  
3/8”  
DRYWALL / SHEETROCK  
CERAMIC TILE  
E-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 5: 120 Volt Installation Instructions  
Important  
• The unit is factory configured for 120 volt  
operation.  
• All wiring must be completed prior to  
installing the unit.  
• Use 2 conductor wire with ground (3 wires • Ensure that the voltage selector switch is  
total) from the power supply (breaker  
panel) to the junction box on the unit.  
in the proper position for the required  
supply voltage prior to connecting the unit  
to the power supply.  
1. Locate the voltage selector switch inside  
the exhaust panel on the top left hand  
corner of the unit. (see figure 2 on page 3)  
2. Confirm the switch is set to 120 volt  
configuration ( 115 volt is printed on  
switch).  
3. Loosen the screw securing the junction  
box cover and remove the cover.  
4. Remove the knockouts (if necessary)  
or use a cable clamp (not provided).  
5. Pull out the four wires marked L1, L2,  
N, and G.  
6. Connect the black L1 wire from the unit to  
the black L1 from the power supply.  
7. Connect the red L2 wire and the N wire  
from the unit to the N wire from the  
power supply.  
JUNCTION BOX  
8. Connect the green ground wire from the  
unit to the ground from the power supply.  
9. Ensure that all connections are tight.  
10. Insert all the wiring back into the unit and  
secure with a cable clamp.  
Junction Box Locator: Figure 6  
E-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wire Connection Diagram: Figure 7  
N - WHITE WIRE  
N- WHITE WIRE  
120 VOLT  
POWER SUPPLY  
L2 - RED WIRE  
BREAKER  
PANEL  
L1 - BLACK WIRE  
G - GREEN WIRE  
L1- BLACK WIRE  
G- GREEN WIRE  
E-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 6: 240 Volt Installation Instructions  
Important  
• The unit is factory configured for 120 volt  
• All wiring must be completed prior to  
installing the unit.  
operation. You must set the voltage  
selection switch to 240 volts (230 volt is  
printed on the switch.  
• Use 3 conductor wire with ground (4 wires • Ensure that the voltage selector switch is  
total) from the power supply (breaker  
panel) to the junction box on the unit.  
in the proper position for the required  
supply voltage prior to connecting the unit  
to the power supply.  
1. Locate the voltage selector switch inside  
the exhaust panel on the top left hand  
corner of the unit. (see figure 2 on page 3)  
2. Confirm the switch is set to 240 volt  
configuration (230 volt is printed  
on switch).  
3. Loosen the screw securing the junction  
box cover and remove the cover.  
4. Remove the knockouts (if necessary) or  
use a cable clamp (not provided).  
5. Pull out the four wires marked L1, L2,  
N, and G.  
6. Connect the black L1 wire from the unit to  
the black L1 from the power supply.  
7. Connect the red L2 wire from the unit to  
the red L2 from the power supply.  
8. Connect the white N wire from the unit to  
the white N wire from the power supply.  
JUNCTION BOX  
9. Connect the green ground wire from the  
unit to the ground from the power supply.  
10. Ensure that all connections are tight.  
11. Insert all the wiring back into the unit and  
secure with a cable clamp.  
Junction Box Locator: Figure 8  
E-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wire Connection Diagram: Figure 9  
N- WHITE WIRE  
L2 - RED WIRE  
N - WHITE WIRE  
L2 - RED WIRE  
240 VOLT  
POWER SUPPLY  
BREAKER  
PANEL  
L1- BLACK WIRE  
G- GREEN WIRE  
L1 - BLACK WIRE  
G - GREEN WIRE  
E-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 7: Wall Mounted Thermostat Wiring For 120/240 Volt  
ATTENTION  
• Install main power connection with  
• Wiring of the thermostat must be  
completed prior to the mounting of  
the unit.  
appropriate voltage as per Section C  
or Section D.  
• Install a 2 conductor wire with ground  
(3 wires total) from the thermostat wall  
box to the junction box on the unit.  
• The following installation instructions are  
for a single pole thermostat.  
1. Loosen the screw securing the junction  
box and remove the cover.  
10. Connect the other end of the green  
(ground) wire from the thermostat wall  
box to the back plate of the wall mounted  
thermostat with a ground screw.  
2. Remove the knockouts (if necessary) or  
use the provided cable clamp.  
11. Ensure that all connections are tight.  
3. Pull out the three wires marked T1, T2,  
and TG. (red, red, and green)  
12. Insert all the wiring of the wall mounted  
thermostat into the wall box.  
4. Remove the wire connector and separate  
the wires marked T1 & T2.  
13. Insert all the wiring back into the unit and  
secure with a cable clamp.  
5. Connect the (red) T1 wire from the unit  
to the white (neutral) wire from the wall  
thermostat box by using a wire connector.  
(not supplied)  
6. Connect the other end of the white  
(neutral) wire from the thermostat wall  
box to the red wire from the wall  
thermostat.  
7. Connect the (red) T2 wire from the unit to  
the black wire from the thermostat wall  
box by using a wire connector.  
(not supplied)  
JUNCTION BOX  
8. Connect the other end of the black wire  
from the thermostat wall box to the black  
wire from the wall thermostat.  
9. Connect the green (ground) TG wire from  
the unit to the green (ground) wire from  
the thermostat wall box by using a wire  
connector. (not supplied)  
Junction Box Locator: Figure 10  
E-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wire Connection Diagram: Figure 11  
2 CONDUCTOR WIRE FROM WALL THERMOSTAT  
T 2 - RED WIRE  
MECHANICAL  
T 1 - RED WIRE  
LINE VOLTAGE  
THERMOSTAT  
WALL MOUNTED  
T G - GREEN WIRE  
E-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 8: Wiring Schematic - Bottom Section & PCB  
E-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Section 9: Wiring Schematic - Heater  
E-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A Division of Twin-Star International, Inc.  
115 S.E. 4th Avenue • Delray Beach, Florida 33483  
Phone: 561-330-3201 • Fax: 561-330-3205  
E-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Toshiba Computer Drive HDTB105XK3AA User Manual
Toshiba Graphics Tablet at330 User Manual
TP Link Network Router TD W8970N User Manual
Trane Thermostat XT500C User Manual
TRENDnet Radio Antenna TEW AI86D User Manual
Velodyne Acoustics Home Theater System VMS 8 User Manual
Victor CRT Television LYT1037 001A User Manual
Viking Gas Grill VGBQ030 2T User Manual
Vivitar Camera Lens VIV 7MM P User Manual
Vox Music Pedal Pedal User Manual