Turbosound Ltd.  
Star Road, Partridge Green  
West Sussex RH13 8RY England  
Tel: +44 (0)1403 711447 Fax: +44 (0)1403 710155  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
An example of this equipment has been tested and found to comply with the  
following European and international Standards for Electromagnetic  
Compatibility and Electrical Safety:  
Radiated Emissions (EU): EN55013-1 (1996)  
RF Immunity (EU):  
EN55103-2 (1996) RF Immunity, ESD,  
Burst Transient, Surge, Dips &Dwels  
EN60065 (1993)  
Electrical Safety (EU):  
IMPORTANT SAFETY INFORMATION  
Do not remove Covers. There are no user serviceable parts inside, please refer servicing to  
qualified service personnel. This equipment must be earthed.  
CAUTION  
RISK OF ELECTRIC SHOCK  
DO NOT OPEN  
DO NOT EXPOSE TO RAIN OR MOISTURE  
ATTENTION  
RISQUE DE CHOC ELECTRIQUE  
NE PAS ENLEVER  
NE PAS EXPOSER A LA PLUIE NI A L’HUMITE  
It should not be necessary to remove any protective earth or signal cable shield connections.  
Do not defeat the purpose of the polarized or grounding-type plug. A polarized plug has two  
blades with one wider than the other. A grounding type plug has two blades and a third grounding  
prong. The wider blade and the third prong are provided for your safety. When the provided plug  
does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.  
Only use this equipment with an appropriate mains cord.  
In the USA the cord should comply with the requirements contained in the Standard for Cord Sets  
and Power Supply Cords, UL 817, be marked VW-1, and have an ampacity rating not less than the  
marked rating of the apparatus.  
LMS-A6 user manual  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
THANKS  
Thank you for choosing the TURBOSOUND LMS-A6 for your application. Please spare a little time  
to digest the contents of this manual, so that you obtain the best possible performance from this  
unit.  
All TURBOSOUND products are carefully engineered for world class performance and reliability.  
If you would like further information about this or any other TURBOSOUND product, please  
contact us.  
We look forward to helping you in the near future.  
UNPACKING THE LMS-A6  
After unpacking the unit please check carefully for damage. If damage is found, please notify the  
carrier concerned at once. You, the consignee, must instigate any claim. Please retain all  
packaging in case of future re-shipment.  
LMS-A6 user manual  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
INTRODUCTION  
The LMS-A6 is a versatile two input, six output, analogue loudspeaker management system in a  
1U rack mount package that is designed for maximum sonic performance. It combines crossover  
and limiter functions and is uniquely configurable to custom requirements.  
The LMS-A6 can be configured for the following modes of operation: stereo 3-way, stereo 2-way,  
mono 4-way, plus mono 2-way. The standard filter provided for the LMS-A6 is a Linkwitz Riley  
response based on two second order Butterworth circuits in series. The response is 24dB/octave  
slope with a corner frequency where the output of the filter is 6dB down from its pass band level.  
The use of these filter realisations has been well documented and provides the best possible  
phase and amplitude response for driving loudspeaker systems.  
Active crossovers versus passive crossovers  
Passive crossovers divide the frequency spectrum after the signal has been raised to high power  
levels. They are generally bulky, heavy and inefficient. Active crossovers utilise IC’s and  
transistors, and divide the frequency spectrum at line level immediately ahead of the amplifiers.  
An active crossover does the same job as a passive crossover, but with more precision, flexibility,  
efficiency and quality. Crossover frequencies can be readily altered to suit different driver  
combinations, the level balance between two or three frequency bands can easily be trimmed, and  
line driving, system muting, signal summing, driver equalisation and phase adjustment facilities  
can all be incorporated into active crossovers.  
FEATURES  
Maximum sonic performance: advanced circuit design for exceptional dynamic range and  
sonic quality.  
Interchangeable frequency programming cards: set the required crossover frequency and  
slope of your loudspeaker system. These are supplied when the unit is shipped from the  
factory.  
A flexible 2 input, 6 output multi-mode format featuring a choice of stereo 3-way, stereo 2-  
way, mono 4-way plus mono 2-way crossover modes with limiters.  
High performance limiters are provided, one for each output band. Limiter threshold is set by  
means of 10-position switches located behind a security panel on the rear of the unit.  
Electronically balanced inputs and outputs: ensures a high level of rejection for common  
mode rejection signals and gives a professional connection to external equipment.  
LMS-A6 user manual  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
FRONT PANEL FUNCTIONS  
2 4  
5
7
8
11 12  
POL  
1 3  
6
9
10  
13  
1. Mono Band 1 – sums the Left and Right Band signals together (up position) and feeds them in  
mono to both Band 1 outputs.  
2. Limiter cancel – disables all limiter functions and causes the LIMITER CANCEL LED to light.  
3. Power Standby switch – determines the power-up mode: in the up (cancel) position the unit  
automatically switches out of mute after six seconds; in the down position the unit remains in  
standby mode with all outputs muted.  
4. Remote Standby cancel – enables (down position) or disables (up position) the REMOTE  
STANDBY function. Inoperable if the remote stanby function has not been wired up.  
5. Phase adjustment – variable adjustment between 0° and 180°.  
6. Gain trim – allows the band 1 gains and band 3 gains to be adjusted to match band 2 where  
speaker/amplifier sensititvities vary for each band.  
7. Polarity – reverses the polarity of the selected frequency band.  
8. Mute LED – indicates mute staus of the selected channel.  
9. Mute key – one latching mute switch per output channel. Press to mute; press again to un-  
mute.  
10. Output meters – LED ladder displays headroom before limiting occurs. The lower four green  
LEDs indicate –24dB, -12dB, -6dB and –1dB respectively, with the orange ‘LIM’ LED set at the  
limiter threshold for that channel. The top, red LED indicates 4dB of limiting.  
11. Power – green LED indicates that power is applied to the unit.  
12. Standy Mute – red LED indicates when the standby mute mode is set.  
13. Limiter Cancel – indicates when the limiter cancel mode is set.  
LMS-A6 user manual  
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
REAR PANEL FUNCTIONS  
AC  
50/60Hz 40VA  
S.No 10  
-
1001  
-
A
230V  
ALWAYS USE SAFETY GROUND  
NO USER SERVICEABLE PARTS INSIDE  
1
2
3
4
5
6
7
1. Mains Power - Connected via a standard IEC socket. A compatible power cord is supplied with  
the unit.  
2. Power Switch.  
3. Mains Fuse - Located in a finger-proof fuseholder adjacent to the mains inlet. Always replace  
this fuse with the correct type as shown on the rear panel legend.  
4. Remote Standby connector – for remote switch connection.  
5. XLR Outputs - 3 pin male XLR connectors are provided for each audio output. All terminations  
are fully balanced, pin 2 Hot, pin 3 Cold and pin 1 Screen (shield).  
6. Limiter threshold – sets limiter threshold for each output band.  
7. XLR Inputs – 3 pin female XLR connectors are provided for each audio input. All terminations  
are fully balanced, pin 2 Hot, pin 3 Cold and pin 1 Screen (shield).  
LMS-A6 user manual  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
SETTING UP AND OPERATING THE LMS-A6  
This section describes the steps and checks to be taken when setting up the unit for the first time,  
and the operation of all the controls and indicators. Some of the custom operating parameters will  
have been set internally when unit left the factory. These are described in this section and you  
must check that these are appropriate for your system.  
Internal factory set parameters  
Check the supplied documentation to ensure these parameters are correct for the particular  
system you are setting up. Incorrect settings can damage the loudspeakers, especially the more  
delicate H.F. unit. If any internal settings are wrong for your system contact your Turbosound  
Dealer about obtaining the correct custom plug-in modules.  
Crossover frequencies and slopes  
There are two stereo frequency programming cards located internally. Card 1 handles band 1  
information and card 2 band 2 & band 3 information. The crossover frequencies and slopes will  
have been specified when the unit was purchased. The limiter time constants and the band edge  
phase adjustment time constants will automatically have been optimised for the corner  
frequencies. The relevant frequency, slope and response type is recorded on a label attached to  
the respective cards and also on a label attached to the right hand side panel of your unit.  
If in the future your unit is to be used to drive loudspeaker systems other than that for which it  
was originally configured, then replacement frequency programming cards can easily be fitted.  
Band Gain  
The gain of each band is normally set to unity, but for systems where the sensitivity of the  
Amplifier/Speaker combinations for each Band are different, the gain of each band may have been  
set to compensate. This allows the Level Trim controls to be nominally set to centre.  
Equalisation  
Either static or dynamic equalisation may have been installed on an optional internal module.  
Mains Supply Voltage  
The unit will have been set for either 115V AC or 230V AC operation as indicated by the label on  
the rear of the unit.  
LMS-A6 user manual  
Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
Connecting inputs and outputs  
This section describes how to connect signals to the LMS-A6 loudspeaker management system.  
The signal inputs are industry standard female XLR connectors and are wired as follows:-  
Pin 1 = GROUND or COMMON  
Pin 2 = HOT or (+) or In-phase  
Pin 3 = COLD or (-) or Out of phase  
The electronically balanced inputs will take a maximum level of +20dBu at 10k ohm impedance.  
They will accept either balanced or unbalanced signals.  
The signal outputs are industry standard male XLR connectors and are wired as follows:-  
Pin 1 = GROUND or COMMON  
Pin 2 = HOT or (+) or In-phase  
Pin 3 = COLD or (-) or Out of phase  
The output impedance is less than 100 ohms and the maximum signal level is +20dB. The  
electronically balanced output stage will drive either balanced or unbalanced loads.  
THE POWER SUPPLY SECTION  
The power supply section includes an IEC connector, ON/OFF switch and an AC fuse.  
Check that the voltage label corresponds with your local mains supply and that the correct AC fuse  
is fitted. If it does not, contact your Turbosound Dealer for instructions on setting the LMS-A6 to  
the correct voltage.  
Connecting to the wrong voltage may damage the unit.  
The unit must be switched OFF before inserting or removing the mains cord.  
When the system is powered and turned on, the green POWER LED on the front panel lights. If the  
LED fails to light when power is applied and switched on check and, if necessary, replace the AC  
fuse. If this does not solve the problem then an internal fuse may have blown. This indicates that  
the unit has a fault and you should contact your Turbosound Dealer for further advice.  
LMS-A6 user manual  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
Power On Standby Mode  
When power is first switched on the LMS-A6 enters STANDBY mode. In this mode all outputs are  
muted to suppress any noise or transients while the circuitry settles down.  
The POWER STDBY switch determines how the unit will behave after power is applied.:  
Switch down: The unit will stay in standby mode. All outputs will stay muted and the red  
STANDBY MUTE LED will light.  
The standby mode is cancelled by pressing any MUTE switch, or momentarily operating the  
REMOTE STANDBY switch.  
Switch up (CANCEL). The unit will remain muted for about six seconds and then automatically  
come out of standby mode.  
In either case the normal band MUTEs will remain as they were when the unit was last used.  
REMOTE STANDBY  
Connecting Remote Standby  
A two wire connection may be made between this connector and a single pole switch located at  
your mixing console, or any other operating position. When this switch is open, the unit functions  
normally and the outputs follow the MUTE switches on the front panel. When the REMOTE switch  
is closed all outputs are muted and the red REMOTE STANDBY LED lights.  
The switch should be floating and isolated from external grounds. No damage will occur if the  
wires short to ground, but proper operation is not guaranteed.  
Remote Standby Cancel  
This switch enables or disables the REMOTE STANDBY function. Putting this switch up (CANCEL)  
will disable the remote function. You may wish to cancel the remote switch if it has been left in  
standby mode but you wish to regain local control. If the Remote Standby function has not been  
wired up this switch does nothing and may be set to either position.  
Mono Band 1  
How loud a system of a given power will go is usually limited by the lower frequencies. This is  
because low frequency signals require higher voltage swings, hence more power, than high  
frequencies. In order to make best use of the headroom available from the amplifiers and low  
frequency loudspeakers it is common practice to send all low frequencies to both channels in a  
stereo system. This has little impact on the stereo image in most situations.  
LMS-A6 user manual  
Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
When this switch is up (on) the Left and Right Band 1 signals are summed together and fed in  
mono to both Band 1 outputs.  
When the switch is down the Left and Right Band 1 signals remain independent from each other.  
Level Trims  
Band 1 and Band 3 have independent gain trims for fine adjustment of the system frequency  
response. If the internal preset band gains have been specified correctly these controls will  
nominally all be set central at 0dB. The +/-6dB range should be more than sufficient to balance  
your system in any realistic situation. Band 2 gain is taken as the reference level, and the Band 1  
and Band 3 controls will be adjusted for correct spectral balance.  
Phase Adjustment  
In a theoretically ideal speaker design the drive units for adjacent bands would be in perfect  
alignment and their signals would combine to give perfect summation at the crossover point.  
However, realistically this seldom occurs and shifting the phase of one of the signals in the  
crossover region will improve the summing, and therefore the frequency response of the system.  
Each phase control gives nearly 180 degrees of adjustment. Used in combination with the POL  
Switch we can achieve continuous adjustment over a full 360 degrees.  
There may be some interaction between the phase controls in each channel, especially if the MID  
Band, Band 2 is fairly narrow, so it is advisable to further fine tune the phase by repeating the  
above process a second time.  
LIMITER SETTING AND OPERATION  
The limiters should be set to a level that affords protection to the speaker drive units. The time  
constants for the limiters are set internally and are preset to be optimum for each frequency band  
being protected.  
Limiter Threshold setting  
The limiter threshold switches are located behind a security cover on the rear of the unit. Each  
Band has an independent 10 position switch to accurately set the threshold. The switches are  
calibrated in 1dB steps from +1dB (Pos0) to +10dB (Pos9)  
In a high powered system where the amplifier output power is below or equal to the rating of the  
speakers the limiter thresholds will nominally be set to 1dB below the clipping level of the  
amplifier. This prevents severe clipping from driving the cones with square waves but does not  
LMS-A6 user manual  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
restrict the full undistorted output of the amplifiers. Note that the actual output power available  
often depends on the mains supply voltage, which may ‘sag’ during heavy performances.  
In a system where the amplifiers are capable of exceeding the ratings of the speakers, set the  
threshold to a level appropriate to the speakers and NOT the clipping point of the amplifier. This is  
normally achieved by feeding the system with pink noise at the maximum level required and then  
turning down each limiter threshold switch until the yellow LIM LED is just flashing.  
Limiter Cancel  
When up (CANCEL), this switch will disable all limiters and the yellow LIMITER CANCEL LED will  
light. It is normally only used when setting up and calibrating - or trouble shooting - the system.  
When the limiters are cancelled the output meters will continue to operate normally up to the  
limiter threshold.  
Output Level and Limiter Meter  
The lower four green LEDs show the signal level in dB relative to the limiter threshold. i.e. they  
always show the signal headroom that is available before the limiters will start operating. The  
yellow LIM LED lights when the threshold has been reached and the limiter is operating. The top  
red LED lights when the input signal is causing 4dB or more limiting to occur. If during use the +4  
LEDS are on for more than occasional brief flashes the input signal is too hot and should be  
turned down at the mixing console to reduce distortion.  
Band Mutes  
Each output has an independent MUTE Switch and red MUTE LED. These are latching switches  
which will retain their settings even when power is turned off and on again.  
Note that the MUTE LED will always follow the position of the MUTE switch regardless of the  
status of the standby mute. If the expected output signal appears to be muted but the MUTE LED  
is not lit then check the STANDBY MUTE LED  
LMS-A6 user manual  
Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
TECHNICAL SPECIFICATIONS  
Inputs  
Two electronically balanced  
> 10k ohms  
Impedance  
CMRR  
>65dB 50Hz - 10kHz  
Six electronically balanced  
< 60ohms  
Outputs  
Source Imp  
Min. Load  
600ohms  
Max. Level  
Frequency Response  
Dynamic Range  
Distortion  
+20dBm into 600 ohm load  
0.5dB 20Hz - 20kHz  
>110dB 20Hz -20kHz. Unwtd  
< 0.02% @ 1kHz, +18dBm  
650 mS. (Increment 2.6 µS)  
adjustable +6dB to -6dB  
Maximum Delay  
Output gain  
High and Lowpass Filters  
Filters  
1 of each per output  
Subsonic filter  
Low mid filter  
High mid filter  
Ultra sonic filter  
Response  
user specified up to 24dB/octave  
user specified up to 24dB/octave  
user specified up to 24dB/octave  
user specified up to 12dB/octave  
Bessel / Butterworth 12/18/24dB /oct and Linkwitz-Riley 24dB /oct  
Limiters  
Threshold  
+1dB to -10dB in 1dB steps  
Output meters  
Connectors  
Inputs  
6 x 6 point, -24dB to +4dB into limit  
3 pin female XLR  
Outputs  
Power  
3 pin male XLR.  
3 pin IEC  
Power  
85 to 130V or 190 to 260V (set internally) @ 50/60Hz  
Fuses  
230V T200mA, 115V T1250mA  
Consumption  
Net weight  
Size  
25 VA  
3.9kg (8.6lbs)  
1.75"(1U) x 19" x 9.9" (44mm x 482mm x 252mm) excl. connectors.  
Due to continuing product improvement the above specifications are subject to change.  
LMS-A6 user manual  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
user manual  
LMS-A6  
WARRANTY  
This product is warranted against defects in components and workmanship only, for a period of  
one year from the date of shipment to the end user. During the warranty period, TURBOSOUND  
will, at its discretion, either repair or replace products which prove to be defective, provided that  
the product is returned, shipping prepaid, to an authorised TURBOSOUND service facility.  
Defects caused by unauthorised modifications, misuse, negligence, act of God or accident, or any  
use of this product that is not in accordance with the instructions provided by TURBOSOUND, are  
not covered by this warranty.  
This warranty is exclusive and no other warranty is expressed or implied. TURBOSOUND is not  
liable for consequential damages.  
LMS-A6 user manual  
Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Turbosound Ltd  
Star Road, Partridge Green  
West Sussex RH13 8RY England  
Tel:+44 (0)1403 711447 Fax: +44 (0)1403 710155  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Teledyne TV Converter Box pjnmoo385 User Manual
Tivoli Audio Clock Radio Dual Alarm Speaker User Manual
TomTom GPS Receiver GO GPS User Manual
Toshiba Vacuum Cleaner SR1054HSPCR User Manual
TP Link Network Router TD W8910GB User Manual
Transition Networks Switch MIL SW8T1GPA User Manual
Tripp Lite Network Cables N201 014 BK User Manual
Troy Bilt Yard Vacuum 24B 060F063 User Manual
Verona Range VEFSGG 365 N User Manual
Walker Lawn Mower MBSSD User Manual