Tripp Lite Switch B060 016 2 User Manual

Owner’s Manual  
NetDirector  
Matrix KVM Switches  
Model #: B060-032 (32-Port, 4-User)  
B060-016-2 (16-Port, 2-User)  
Tripp Lite World Headquarters  
1111 W. 35th Street, Chicago, IL 60609 USA  
Note: Follow these instructions and operating procedures to ensure correct performance and to prevent damage  
to this unit or to its connected devices.  
Copyright © 2007 Tripp Lite. All rights reserved. All trademarks are the property of their respective owners.  
The policy of Tripp Lite is one of continuous improvement. Specifications are subject to change without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Features  
• Two consoles (for B060-016-2) or four consoles (for B060-032) independently and simultaneously  
control up to 16 (for B060-016-2) or up to 32 (for B060-032) directly connected computers  
• Daisy-chain up to 7 additional units  
• Cascade up to 16 (for B060-016-2) or up to 32 (for B060-032) compatible KVM switches from each  
station on the chain  
• Control up to 4,096 computers on a daisy-chained/cascaded installation  
• Compact design - RJ45 connectors allow rack mounting in a 19", 1U, system rack  
• Multi-platform support: PC, Mac and Sun  
• Console conversion - any type of console can control any type of computer - mixed combinations (PS/2  
& USB) supported on both the console and computer sides  
• PS/2 keyboard and mouse emulation - computers boot even when the console focus is elsewhere - Keep Alive  
feature ensures that the keyboard and mouse work properly even if the switch temporarily loses power  
• Hot pluggable; add or remove components without having to power off the switch  
• No software required; convenient computer selection via intuitive hotkey combinations or On Screen  
Display (OSD) menus  
• OSD port list automatically expands when stations are added - port names are automatically reconfigured  
when the station sequence is changed  
• OSD screen automatically adjusts to resolution changes  
• Auto Scan feature for monitoring user-selected computers  
• Three level password security: Super Administrator, Administrator, and Users  
• LCD, VGA, SVGA, XGA, and MultiSync support; DDC2B  
• Superior video quality - up to 1024x768 @ 60Hz at 500ft.  
• Auto Signal Compensation (ASC) assures optimum video resolution for distances up to 500ft between the  
switch and the consoles or computers - no DIP switch setting required  
• Lifetime firmware upgrading via flash ROM  
Hardware Requirements  
Console  
The following equipment must be used for each console:  
• A VGA, SVGA, or Multisync monitor capable of the highest resolution that you will be using on any  
computer in the installation.  
• Either a PS/2 or a USB keyboard and mouse.  
Computers  
The following equipment must be installed on each computer:  
• An HD15 video port.  
• Either a PS/2 style (MiniDIN6) mouse port and PS/2 style keyboard port; or USB ports (for a  
USB keyboard and USB mouse); or, for legacy Sun systems, a Sun style keyboard port (MiniDIN8).  
Cables and Interface Modules  
The following cables are required for use with the Modular Matrix KVM switch:  
Function  
Cable  
Console Interface Module to B060 Series KVM  
B060 Series KVM to Server Interface Module  
Console Interface Modules  
Server Interface Modules  
Cat5e Patch Cable (Tripp Lite  
N001 Series Patch Cables)  
B062-001-PS2  
B062-001-USB  
B054-001-PS2  
For PS/2 Console  
For USB Console  
For PS/2 Server  
For SUN Server  
For USB Server  
B054-001-SUN  
B054-001-USB  
Daisy-chain Cables  
P770 Series of Cables  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction (continued)  
B060 Series Front View (B060-032 Shown)  
1
2
3
4
5
6
7
8
9
10  
26  
11  
27  
12  
28  
13  
29  
14  
30  
15  
31  
16  
32  
17  
18  
19  
20  
21  
22  
23  
24  
25  
STATION  
ID  
F/W UPGRADE  
POWER  
32-PORT (4 USER)  
RESET  
NORMAL RECOVER  
MATRIX KVM SWITCH  
MODEL: B060-032  
1
2
3
4
5
1. Firmware Upgrade Recovery Switch  
During normal operation and while performing a firmware upgrade, this switch should be in the  
NORMAL position. If a firmware upgrade operation does not complete successfully, slide this switch to  
the RECOVER position and do a warm reset (see p. 31), to return the switch to its prior firmware state.  
After returning the switch to its prior firmware state, slide the switch back to the NORMAL position to  
attempt the firmware upgrade again, or to use the switch with its prior firmware.  
2. Port LEDs  
The Port LEDs are multicolored (Red / Green / Amber), and provide status information about their  
corresponding CPU Ports as follows:  
Color  
Condition Indication  
Amber Steady  
Flashing  
Port is selected and the connected server is on.  
Port is selected; Port is connected to a powered ON KVM switch  
Port is selected but connected server is OFF  
Port is not selected, the connected server is ON  
Port is not selected: Port is connected to a powered ON KVM switch  
Port is not selected and the server is OFF  
Red  
Green  
Steady  
Steady  
Flashing  
Off  
3. Reset Switch  
Pressing this switch in performs a System Reset.  
Note: This switch is semi-recessed and must be pushed with a thin object - such as the end of a paper  
clip, or a ballpoint pen.  
4. Power LED  
Lights to indicate that the B060 Series KVM is powered up and ready to go.  
5. Station ID LED  
The Station ID on the B060 Series KVM is displayed here. If this is a Single Station installation (see p.  
8), or the First Station on a Daisy Chained installation (see p. 10), the KVM has a Station ID of 01.  
On a Daisy Chained installation, the KVM auto-senses its position and displays the Station ID that cor-  
responds to its place in the chain. (see Port ID Numbering, p. 17 for details).  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction (continued)  
B060 Series Rear View (B060-032 Shown)  
6
2
1
3
5
4
1. Power Socket  
The power cord to the AC source plugs in here.  
2. Power Switch  
This is a standard rocker switch that powers the unit On and Off.  
3. Console Port Section  
The Cat5e cables from the Console Interface Modules plug in here.  
4. Firmware Upgrade Port  
The Firmware Upgrade Cable that transfers the firmware upgrade data from the administrator's  
computer to the KVM (see p. 31), plugs into this RJ45 connector.  
5. Daisy Chain Ports  
When Daisy Chaining Units (see p. 10), the daisy chain cables plug in here.  
The upper port is the Chain In port; the lower one is the Chain Out port. The Chain In port is not used  
on the Master (First Stage) unit.  
6. Computer Port Section  
The Cat5e cables that link the KVM to KVM cables that connect to the computers plug in here.  
Console Interface Modules  
The purpose of the Console Interface Modules is to provide flexibility for your installation by allowing  
PS/2 and USB interfaces to be mixed and matched at the console side. With this approach, either type of  
console can access and control any type of computer. The modules currently available are shown in the  
table below:  
Module  
Type  
B062-001-PS2  
B062-001-USB  
For PS/2 consoles  
For all USB consoles (including Mac and Sun)  
Console Interface Modules Front View  
Power LED  
Link LED  
The front panel configuration of both B062 series modules is the same. It consists of two LEDs:  
Link LED lights to indicate that the module is connected to the KVM.  
Power LED lights to indicate that the module is turned On and receiving power.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction (continued)  
Console Interface Modules Rear View  
B062-001-PS2  
B062-001-USB  
1
2
3
4
1
2
3
4
1. Power Jack  
The power adapter cable plugs in here.  
2. I/O Jack  
The cable that links the module to the B060-032/B060-016-2 plugs in here.  
3. Firmware Upgrade Recovery Switch  
During normal operation and while performing a firmware upgrade, this switch should be in the  
NORMAL position. See p. 4 for details about this switch.  
4. Console Port Section  
The cables from your keyboard, monitor and mouse plug in here. The keyboard and mouse ports of both  
modules are labeled with an appropriate icon to indicate which is which. The B062-001-PS2 ports are  
also color-coded.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
Overview  
For convenience and flexibility that allows mixing the PS/2 and USB interfaces, the KVM’s design  
utilizes Console Interface Modules that act as signal translation intermediaries between the consoles and  
the switch, and Server Interface Modules, that serve as intermediaries between the switch and the computers:  
B054 Series Console  
Interface Module  
B054 Series Console  
Interface Module  
Multiple Modules  
Multiple Modules  
B061 Series Console  
Interface Module  
B054 Series Console  
Interface Module  
B054 Series Console  
Interface Module  
A separate Console Interface Module is required for each console you connect. Likewise, a separate Server  
Interface Module is required for each computer connection. The Server Interface Module model number  
for each interface is shown in the table below. The model numbers of the Console Interface Modules are  
given in the table on p. 4.  
Interface  
PS/2  
Server Interface Modules  
B054-001-PS2  
SUN  
B054-001-SUN  
USB  
B054-001-USB  
Before you Begin  
1. Make sure that power to all the devices you will be connecting up have been turned off. You must  
unplug the power cords of any computers that have the Keyboard Power On function.  
2. To prevent damage to your installation, make sure that all devices on the installation are properly grounded.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Single Stage Installation  
In a Single Stage installation, there are no additional KVM switches daisy chained or cascaded down from  
the first unit. To set up a single stage installation, refer to the diagram on p.9 (the numbers in the diagram  
correspond with the numbers of the instruction steps), and do the following:  
1. Connect the Console to the Console Interface Module  
Plug your keyboard, mouse, and monitor into their respective ports on the Console Interface Module.  
Each port is marked with an icon to indicate itself.  
Note: The diagram shows the rear panel of both the B062-001-PS2 (PS/2 port) and B062-001-USB  
(USB port) modules.  
2. Connect the Console Interface Module to the B060-032/B060-016-2  
Use Cat5e cable to connect the Link port of the module to one of the Console ports on the  
B060-032/B060-016-2's rear panel. Up to four consoles can be connected per KVM.  
Note: The distance between the Console Interface Module and the B060-032/B060-016-2 must not  
exceed 500 feet. (Repeat Steps 1 and 2 for any other consoles you wish to connect.)  
3. Connect the B060-032/B060-016-2 to the Server Interface Module  
Use Cat5e cable to connect any available CPU Port to a Server Interface Module that is appropriate for  
the computer you are installing.  
Note: The distance between the B060-032/B060-016-2 and the Server Interface Module must not exceed  
500 feet.  
4. Connect the Server Interface Module to the Computer  
Plug the connectors on the Server Interface Module into the appropriate ports of the computer you are  
installing.  
Note: Repeat steps 3 and 4 for all the computers you wish to connect. Up to 32 computers can be con-  
nected in this fashion.  
5. After all computers have been cabled up, plug the female end of the power cord into the  
B060-032/B060-016-2’s Power Socket; plug the male end into an AC power source.  
6. For each Console Module, plug its power adapter into an AC source; plug the power  
adapter cable into the unit’s power jack.  
7. Turn on the power to the B060-032/B060-016-2.  
8. Turn on the power to the computers.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Single Stage Installation  
1
4
B062-001-PS2  
Multiple Modules  
2
6
3
5
Multiple Modules  
B062-001-USB  
USB Cable Connection  
PS/2 Cable Connection  
3
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Multilevel Installations  
The number of computers that can be added to your installation can be greatly expanded by performing a  
multilevel installation. The B060 Series KVM supports three types of multilevel installation:  
• Daisy chained  
• Cascaded  
• Daisy chained plus cascaded  
Overview  
Daisy chaining refers to connecting two or more KVM switches via dedicated daisy chain ports. The  
switches are strung together in a chain (see the diagram on p. 11).  
With daisy chaining, none of the switch’s CPU ports are used to connect to the next switch. The port  
capacity of a daisy-chained installation is the total of all the CPU ports of all the KVM switches on the  
chain. For example, a B060-032 has 32 CPU ports. On an installation with eight daisy-chained switches  
the number of available ports is 32 x 8 = 256.  
Cascading involves using the CPU ports of a Parent KVM switch (one that is above a switch linked down  
from it) to connect to a Child KVM switch. Cascading adds capacity to a KVM installation, but the parent  
loses one CPU port for each cascaded KVM.  
The B060 Series KVM supports both daisy chaining and cascading. In addition, it supports combining the  
two methods—providing enormous capacity and flexibility for expanding the installation. The following  
sections provide the information and procedures involved in setting up the various multilevel installations.  
Daisy Chaining  
Up to 7 additional B060 Series KVM units can be daisy chained together; each capable of supporting four  
independent consoles. The first B060 Series KVM is considered the Master unit; the daisy chained  
B060 Series KVMs are considered Slaves.  
In a complete daisy chained installation, the consoles that belong to the Master switch can access and  
control all of the computers (up to 256) on the installation. The consoles belonging to each Slave switch  
only control the computers (up to 32) connected to their switch.  
To set up a daisy chained installation, refer to the diagram on page 11 and do the following:  
1. Make sure that power to all the devices you will be connecting up has been turned off.  
2. Use a daisy chain cable set (described in the Cables section, p. 3), to connect the Chain Out port of  
the parent B060 Series KVM unit to the Chain In port of the child B060 Series KVM unit (First  
Station Out to Second Station In, Second Station Out to Third Station In, etc.).  
Note: You cannot use the Chain In port of the First Station B060 Series KVM, since it is the high-  
est level parent.  
3. If you wish to install any consoles on this switch, follow the procedure described for the Single  
Stage Installation on p. 8.  
4. Use Cat5e cabling and a Server Interface Module (described in the Cables section, p. 4), to connect  
any available CPU Port on the B060 Series KVM to the Keyboard, Video and Mouse ports of the  
computers you are installing.  
5. Repeat the above steps for any additional B060 Series KVM units you wish to add to the chain.  
6. Plug the power cord into an AC power source and into the B060 Series KVM's power socket.  
7. Power up the installation according to the following procedure:  
a. Switch on the power for the First Station. Wait for the unit to ascertain its Station ID and  
display it on the Station ID LED. (The Station ID for the First Stage unit is 01, the ID for the  
Second Stage unit is 02, the ID for the Third Stage unit is 03, etc.).  
b. Switch on the power for each Station on the installation in turn (Second Station, then Third  
Station, etc.). In each case, wait for the Station ID to be ascertained and displayed on the  
current Station before powering on the next one.  
c. After all the Stations are up, power on the computers.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Multilevel Installations  
1
B062-001-PS2  
Multiple Modules  
Multiple Modules  
Multiple Modules  
Multiple Modules  
B062-001-USB  
Cascading  
Another way of adding capacity to your installation is to cascade additional KVM switches from the  
B060 Series KVM’s CPU ports. Up to 16 or 32 additional KVM switches can be cascaded depending on  
the model. Cascading does not increase the number of consoles that can be used to control the computers  
(unlike daisychaining).  
Note: 1. While you can daisy chain B060 Series KVMs, you cannot cascade them.  
2. Switches cannot be cascaded beyond the second stage.  
In a cascaded installation, the B060 Series KVM is considered the First Stage unit; cascaded KVM  
switches are considered Second Stage units. The B060 Series KVM supports two types of cascade: 1)  
Protocol Interface Cascading (see the installation diagram under Protocol Interface Cascading section), and  
2) Physical Interface Cascading (see the installation diagram under Physical Interface Cascading section).  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Multilevel Installations  
Protocol Interface Cascading  
Protocol Interface Cascading refers to cascading to a second stage KVM switch (such as the eight port  
Tripp Lite B007-008) that uses the same data transfer protocol as the first stage B060 Series KVM.  
With this type of cascade, all of the separate switch OSDs are integrated so that when the B060 Series KVM  
consoles bring up the OSD, it lists all of the computers connected to all of the units.  
To set up a Protocol Interface Cascade, refer to the installation diagram below and do the following:  
1. Make sure that power to all the devices you will be connecting up has been turned off.  
2. Use Cat5e cable to connect any available CPU Port on the First Stage unit (the B060 Series KVM) to  
a PS/2 style Server Interface Module (as described in the Cables section, p. 3); plug the adapter  
cable’s KVM connectors to the Keyboard, Video, and Mouse Console ports of the Second Stage unit.  
Note: The distance between the Second Stage unit and the B060 Series KVM must not exceed 500ft.  
3. Use KVM cable sets (as described in the Cables section of the Second Stage unit's User Manual), to  
connect any available CPU port on the Second Stage unit to the Keyboard, Video, and Mouse ports of  
the computer you are installing.  
4. Plug the Second Stage unit's power adapter into an AC source; plug the power adapter cable into the  
unit’s Power Socket.  
5. Repeat steps 2 - 4 for any other Second Stage units you wish to connect.  
6. Turn on the power for the First Stage unit; turn on the Second Stage unit, turn on the power to all the  
computers.  
1
B062-001-PS2  
Multiple Modules  
Multiple Modules  
B054-001-PS2  
B007-008  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Multilevel Installations  
Physical Interface Cascading  
Physical Interface Cascading refers to cascading to a second stage KVM switch (such as the Tripp Lite  
B022-016) that doesn’t utilize the same protocol as the first stage B060 Series KVM, but uses the same  
physical interface (PS/2 or USB ports, for example).  
The advantage of cascading to a switch like the B022-016 is that it yields enormous expansion capability.  
For example, since the B060-032 can be daisy chained to 31 additional B022-016s, up to 16,384 computers can  
be controlled from a single B060-032 (32 B060-032 ports x 32 B022-016s x 16 ports per switch = 16,384 ports).  
The operational difference between this method and Protocol Interface Cascading is that since the OSD  
protocols are not the same, the OSDs of the cascaded B022-016s cannot be integrated. Unlike Protocol  
Interface Cascading, the OSD that the operator works with is the OSD for each particular B022-016 - not  
an OSD that incorporates all of the switches on the installation.  
Therefore, in order to access a computer connected to a particular B022-016, the operator must first bring  
up the B060 Series KVM’s OSD to access the target B022-016. The B022-016's OSD is then activated in  
order to access the target computer.  
In this type of installation, the B060 Series KVM is considered the First Stage unit; the B022-016 is con-  
sidered the Second Stage unit. If there are additional B022-016s daisy chained down from the Second  
Stage B022-016, the entire chain is seen as a Second Stage unit, with the top level B022-016 (the Master  
switch) as the OSD access point for the entire chain.  
To set up a Physical Interface Cascade, refer to the installation diagram below, and do the following:  
1. Make sure that power to all the devices you will be connecting up has been turned off.  
2. Use Cat5e cable to connect any available CPU Port on the First Stage unit (the B060 Series KVM) to a  
PS/2 style Server Interface Module (as described in the Cables section, p. 3); plug the Server Interface  
Module's KVM connectors to the Keyboard, Video, and Mouse Console ports of the B022-016.  
Note: The distance between the Second Stage unit and the B060 Series KVM must not exceed 500ft.  
3. Use KVM cable sets for the B022-016 to connect any available CPU port on the Second Stage unit  
to the Keyboard, Video, and Mouse ports of the computers you are installing. Note that the B022-  
016 and the B060 Series KVM use different types of cables.  
4. Plug the power cord into the B022-016 switch's Power Socket and into an AC source (such as a  
surge suppressor or UPS).  
5. Repeat steps 2 - 4 for any other top level Second Stage units you wish to connect.  
6. Turn on the power for the First Stage unit; turn on the power for all Second Stage units; turn on the  
power to all the computers.  
Note: If you are daisy chaining B022-016s, follow the instructions provided in the B022-016 User  
Manual for chaining. Power on each chain according to the instructions in the manual.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Multilevel Installations  
Physical Interface Cascading  
1
B062-001-PS2  
Multiple Modules  
Multiple Modules  
B054-001-PS2  
B022-016  
B022-016  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Daisy Chaining Plus Cascading Expansion  
B060 Series KVMs can be daisy-chained to other B060 Series KVMs to produce extremely large KVM  
matrixes. Under Protocol Interface Expansion, up to 8 daisy-chained B060 Series KVMs can have an 8-  
port B007-008s cascaded from each port, allowing up to 2,048 computers and up to 32 consoles in a full  
installation (8 x 32 x 8) when considering the 32-port B060-032.  
Protocol Interface Expansion  
To set up a daisy chained/cascaded installation under Protocol Interface Expansion, refer to the diagram  
below, and do the following:  
1. Follow the cabling procedures given in the Cascading and Daisy Chaining sections.  
2. Power up the daisy chained B060 Series KVM Stations according to the sequence given in the Daisy  
Chaining section (p. 10).  
3. After all the daisy chained B060 Series KVM Stations are up, power on the cascaded Stations.  
4. After all the cascaded Stations are up, power on the computers.  
B054-001-PS2  
B007-008  
B060-032  
B054-001-PS2  
B007-008  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Daisy Chaining Plus Cascading Expansion  
Physical Interface Expansion  
To set up a daisy chained/cascaded installation under Physical Interface Expansion, refer to the diagram  
below, and do the following:  
1. Follow the cabling up procedures given in the Daisy Chaining sections.  
2. Power up the daisy chained B060 Series KVM Stations according to the sequence given in the Daisy  
Chaining section (p. 10).  
3. After all the daisy chained B060 Series KVM Stations are up, power up each chain of B022-016s  
according to the instructions provided in the B022-016 User Manual.  
4. After all the B022-016s are up, power on the computers.  
B054-001-PS2  
B022-016  
B022-016  
B054-001-PS2  
B022-016  
B022-016  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Topology Considerations  
The use of RJ-45 CPU connectors, combined with our Auto Signal Compensation (ASC), allow signals to  
travel up to 500 feet (150 meters) and still maintain reliability and high video resolution. This allows the  
B060 Series KVM installation to take advantage of the internal Cat5e and Cat6 wiring built in to most  
modern commercial buildings.  
Note: Although the B060 Series KVM supports legacy CAT5 wiring, the performance and video quality  
may degrade over longer distances.  
Since the data signals are not transmitted in packets, the transmission cannot go through network hubs or  
switches. Passive components such as patch panels, keystone jacks, patch cables, etc. can be used to  
channel the traffic.  
Basic Operations  
Hot Plugging  
The B060 Series KVM supports hot plugging—components can be removed and added back into the installa-  
tion by unplugging their cables from the ports without the need to shut the unit down. In order for hot  
plugging to work properly, however, the procedures described below must be followed:  
Switching Station Positions: On daisy chained installations, you can switch station positions by simply  
unplugging from the old parent and plugging into a new one.  
Hot Plugging Console Ports: Keyboard, monitor, and mouse can all be hot plugged. If you experience a  
problem after you plug in a new mouse, do a system reset by pressing the reset switch on the B060  
Series KVM’s front panel (see p. 4 for details). If this doesn't resolve the problem, restart the computers  
that have the problem.  
Powering Off and Restarting  
Powering off the B060 Series KVM does not affect the computers attached to it. When you restart the  
B060 Series KVM, you will regain control immediately. To replace a B060 Series KVM, simply power it  
down; unplug the cables; plug them into the new unit; and power the new unit on.  
Note: If any of the computers behave strangely after powering off and restarting, or changing a switch,  
simply restart the computer.  
Port Selection  
Port Selection is accomplished either by entering Hotkey combinations from the keyboard, or by means of  
the B060 Series KVM’s OSD (On Screen Display). OSD Operation is discussed in detail in the next chap-  
ter; Hotkey Port Selection is discussed on p. 27.  
Although hotkeys are handy for a single stage installation, we strongly recommend you use the more  
powerful and versatile OSD - especially for daisy chained, cascaded, and combined installations.  
Port ID Numbering  
Each CPU port on a B060 Series KVM installation is assigned a unique Port ID. You can access and control  
any computer on the installation by specifying the Port ID of the port that it is connected to. Depending on  
where the computer is on the installation, its Port ID will either have two or three parts.  
Single Stage and Daisy Chained Installations  
For single stage and daisy-chained installations, the Port ID is made up of two parts: a Station Number and  
a Port Number:  
• The Station Number - is a two digit number which reflects the switch’s position in the daisy chain  
sequence. This corresponds to the number displayed on the front panel Station ID LED.  
• The Port Number - reflects the port on the B060 Series KVM Station that the computer is connected to.  
• The Station Number precedes the Port Number.  
Note: Station numbers from 1 - 9 are padded with a preceding zero, so they become 01 - 09.  
For example, a computer attached to Port 12 of Station 6 would have a Port ID of: 06-12.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation (continued)  
Basic Operations  
Cascaded Protocol Interface Installations  
The Port ID for computers on Protocol Interface cascaded installations is made up of three parts:  
• The Station Number of the B060 Series KVM  
• The Port Number on the B060 Series KVM that the cascaded KVM switch links back to.  
• The Port Number on the cascaded KVM switch that the computer is connected to.  
For example, a computer attached to Port 8 of a KVM switch that is cascaded from Port 15 of a B060  
Series KVM in the Station 10 position, would have a Port ID of: 10-15-8.  
Cascaded Physical Interface Installations  
Under Physical Interface Expansion, B022-016s are cascaded down from the B060 Series KVM. Since  
the OSD protocols are different, there are separate OSDs for each. When you invoke the OSD (see p. 19),  
the B060 Series KVM OSD screen comes up first. When you select the port that the target B022-016 is  
connected to, its OSD screen replaces the B060 Series KVM’s, and you can select the computer you want  
to access from the B022-016 OSD screen. Aside from this difference, the port numbering follows the  
examples shown above.  
User Management and Security  
The B060 Series KVM permits the creation of 6 operator profiles when the switch is either on a stand  
alone installation or is the Master switch of a multilevel installation, as follows:  
• 1 Super Administrator  
• 1 Administrator  
• 4 Users  
On a single stage installation, up to two (for B060-016-2) or up to four (for B060-032) operators have  
simultaneous and independent control of up to 16 (for B060-016-2) or up to 32 (for B060-032) computers.  
In a daisy-chained installation, a maximum of 16 or 32 operators can exist (2 or 4 operators on the master  
KVM who can access all systems, and 2 or 4 operators on each of the 7 Slave KVMs each having access  
to the 16 or 32 ports on that KVM depending on the model). Each Slave B060 Series KVM also has 6  
operator profiles, as above.  
Note: 1. The Super Administrator can log in on a slave unit, but his or her authority only governs the  
segment he or she logs in on-just like that of an ordinary Administrator.  
2. Operator profiles are different from actual operators. For example, the B060-032 has four console  
ports and allows four actual operators to access the switch simultaneously. Operator profiles specify  
the rights assigned to particular operators. Theoretically, one operator can use the same operator  
profile to occupy all 4 console ports.  
The Super Administrator has administrative power over the whole chain, he can assign and change pass-  
words and access rights for all operators on all segments (see SET USERNAME AND PASSWORD, p. 23,  
and SET ACCESSIBLE PORTS p. 24).  
The Administrator’s power is limited to only that segment of the installation that the B060 Series KVM he is  
logged in on controls. He can assign and change passwords and access rights for all operators on his segment.  
Both Super Administrator and Administrator have full User rights. The four Users have no administrative  
rights. Depending on the permissions granted by the Super Administrator or Administrator, Users have  
varying degrees of control over the computers on the installation: Full Access; View Only; No Access.  
These rights are assigned on a port-by-port basis.  
Operators (Super Administrator, Administrators, and Users) on the Master B060 Series KVM can have  
User access rights to all ports on the Slave KVMs. Access rights are given by the Super Administrator or  
Administrator with the BUS AUTHORIZATION function (see p. 24).  
The operators on Slave KVMs can only access computers on their segment. This includes any computers  
connected to KVM switches that are cascaded down from the B060 Series KVM they are logged in on.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OSD Operation  
OSD Overview  
The B060 Series KVM’s On Screen Display (OSD) provides a visual, menu-driven, mouse enabled, inter-  
face that offers quick and convenient computer access and control, as well as efficient system administra-  
tion including user management (access rights, passwords, etc.).  
Each OSD menu option activates a function that configures and controls the operation of the KVM instal-  
lation. All procedures start from the OSD Main Screen. To bring up the OSD Main Screen, tap the Scroll  
Lock key twice.  
Note: [Scroll Lock] is the default OSD hotkey. You can optionally change the Hotkey to the Ctrl key  
(see OSD Hotkey, p. 22, for details).  
The login dialog box appears:  
E N T E R N A M E A N D PA S S W O R D  
U S E R N A M E  
PA S S W O R D  
:
:
Key in a valid username and password, then press [Enter].  
Note: If this is the first time that the OSD is being run, or if the password function has not been set, simply  
press [Enter]. The OSD Main Screen comes up in Super Administrator Mode. In this mode, you have  
access to all Administrator and User functions, and can set up operations (including password authorization  
for the future), as you would like.  
After you log in, a screen similar to the one below appears:  
F1: GOTO  
F2: LIST  
F3: SET F5: SKP  
F4: ADM F6: BRC  
F7: SCAN X  
F6: LOUT  
SUPERADMINISTRATOR  
SN:02/08  
LIST:ALL  
PN  
QV  
NAME  
01•  
02•  
03•  
06•  
TRIPPLITE.1  
TRIPPLITE.2  
TRIPPLITE.3  
FAXSERVER 1  
FAXSERVER 1  
WEBSERVER1  
WEBSERVER2  
MAILSERVER1  
05•  
06•3  
07•4  
08•5  
Note: 1. The diagram depicts the Super Administrator's Main Screen. The User Main Screen does not  
show the F4 and F6 functions, since these are reserved for the Administrator and cant be  
accessed by ordinary Users.  
2. The OSD always starts in List view, with the highlight bar at the same position it was in the  
last time it was closed.  
3. Only the ports that have been set accessible by the Administrator for the currently logged in  
User are visible (see SET ACCESSIBLE PORTS, p. 24, for details).  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OSD Operation (continued)  
OSD Main Screen Headings  
Heading Explanation  
SN  
This field shows the Station Number that the currently selected port is connected to.  
The first number is the Station’s position in the chain; the second number shows the  
total number of stations in the chain.  
PN  
This column lists the Port Numbers for all the CPU ports on the installation. The  
simplest method to access a particular computer is move the Highlight Bar to it, then  
press Enter.  
QV  
If a port has selected for Quick View scanning (see Set Quick View Ports, p. 24), an  
arrowhead displays in this column to indicate so.  
¤
The computers that are powered on and are On Line have a Sun symbol in this column  
to indicate so.  
NAME  
If a port has been given a name (see Edit Port Names, p. 23), its name appears  
in this column.  
OSD Navigation  
Use the following procedures to navigate through OSD menus:  
• To dismiss the Main Screen, and deactivate OSD, Click the X at the upper right corner of the OSD  
Window; or press [Esc].  
• To Logout, Click F8 at the top of the Main Screen, or press [F8].  
• To move up or down through the list one line at a time, Click the Up and Down Triangle symbols  
(ꢀꢁ) or use the Up and Down Arrow Keys. If there are more list entries than there is room for on the  
Main Screen, the screen will scroll.  
• To move up or down through the list one screen at a time, Click the Up and Down Arrow  
symbols (ꢀꢁ), or use the [Pg Up] and [Pg Dn] keys. If there are more list entries than there is room  
for on the Main Screen, the screen will scroll.  
• To activate a port, Double Click it, or move the Highlight Bar to it then press [Enter].  
• After executing any action, you automatically go back to the menu one level above.  
OSD Functions  
OSD functions configure and control the OSD. Examples of what can be accomplished with the OSD  
include: rapidly switching to any port; auto scanning specifically selected ports; limiting the list of ports you  
wish to view; designating a port as a Quick View Port; managing port names; user management, system  
administration, and making OSD setting adjustments.  
To access an OSD function:  
1. Either Click a Function Key field at the top of the Main Screen, or press a Function Key on the key-  
board.  
2. In the Submenus that appear make your choice either by Double Clicking it, or moving the Highlight  
Bar to it, then pressing [Enter].  
3. Press [Esc] to return to the previous menu level.  
A complete description of the B060 Series KVM’s OSD operations are given in the sections that follow.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OSD Operation (continued)  
OSD Functions  
F1 GOTO  
GOTO allows you to switch directly to a port either by keying in the port’s Name, or its Port ID.  
• To use the Name method, key in 1; key in the port’s Name; then press [Enter].  
• To use the Port ID method, key in 2; key in the Port ID; then press [Enter].  
• Key in 3, to go to a Station on the installation other than the ones connected to the Station you are logged  
in on (see Bus Authorization, p. 24). Only an authorized operator at the Master Station  
(the top level B060 Series KVM) can use this function.  
Note: You can key in a partial Name or Port ID. In that case, the screen will show all the computers that  
the User has View rights to (see SET ACCESSIBLE PORTS, p. 24), that match the Name or Port ID  
pattern, regardless of the current List settings (see F2 LIST below, for details).  
To return to the OSD Main Screen without making a choice, press [Esc].  
F2 LIST  
Many of the OSD functions only operate on the computers that are currently displayed (listed) on the Main  
Screen. This function lets you broaden or narrow the scope of which ports the OSD lists on the Main  
Screen. The submenu choices and their meanings are given in the table below:  
Choice  
Meaning  
ALL  
Lists all of the ports on the installation.  
POWERED ON  
QVIEW  
Lists only the ports that have their attached computers Powered On.  
Lists only the ports that have been selected as Quick View Ports  
(see SET ACCESSIBLE PORTS, p. 24).  
QVIEW + POWERED ON  
Lists only the ports that have been selected as Quick View Ports  
(see SET QUICK VIEW PORTS, p. 24), and that have their  
attached computers Powered On.  
Move the Highlight Bar to the choice you want, then press [Enter]. An icon appears before the choice to  
indicate that it is the currently selected one.  
F3 SET  
This function allows each operator to set up his own working environment. A separate profile for each is  
stored by the OSD and is activated according to the Username that was provided during Login.  
To change a setting:  
1. Double Click it; or move the highlight bar to it, then press [Enter].  
2. After you select an item, a submenu with further choices appears. To make a selection, either Double  
Click it or move the Highlight Bar to it, then press [Enter]. An icon appears before the selected choice  
to indicate which one it is.  
Note: All your setting changes are stored in temporary memory and remain in effect for the duration of  
your session. The changes only become permanent when you Log out of the OSD (see p. 26). If you shut  
down the B060 Series KVM without first logging out, your changes are discarded.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OSD Operation (continued)  
OSD Functions  
The settings are explained in the following table:  
Setting  
Function  
OSD HOTKEY  
Selects which Hotkey activates the OSD function:  
[Scroll Lock] [Scroll Lock] or [Ctrl] [Ctrl].  
Since the Ctrl key combination may conflict with programs running on the  
computers, the default is the Scroll Lock combination.  
PORT ID  
DISPLAY POSITION  
Allows you to position where the Port ID appears on the monitor.  
The default is the upper left corner, but you can have it appear anywhere on  
the screen.  
Use the Mouse or the Arrow Keys plus Pg Up, Pg Dn, Home, End, and 5  
(on the numeric keypad with Num Lock off), to position the Port ID display,  
then Double Click or press [Enter] to lock the position and return to the Set  
submenu.  
PORT ID  
DISPLAY DURATION  
Determines how long a Port ID displays on the monitor after a port  
change has taken place. The choices are: User Defined - which lets you select  
the amount of time (from 1 - 255 sec.); and Always On - which displays the  
Port ID at all times. If you select User Defined, key in the number of seconds,  
then press [Enter].  
The default is 3 Seconds. A setting of 0 (zero) disables this function.  
PORT ID  
DISPLAY MODE  
Selects how the Port ID is displayed: the Port Number alone  
(PORT NUMBER); the Port Name alone (PORT NAME); or the Port  
Number plus the Port Name (PORT NUMBER + PORT NAME).  
The default is PORT NUMBER + PORT NAME).  
SCAN DURATION  
SCAN/SKIP MODE  
Determines how long the focus dwells on each port as it cycles through the  
selected ports in Auto Scan Mode (see F7 SCAN, p. 25). Key in a value from  
1 - 255 seconds, then press [Enter].  
Default is 5 seconds; a setting of 0 disables the Scan function.  
Selects which computers will be accessed under Skip Mode (see F5 SKP,  
p. 25), and Auto Scan Mode (see F7 SCAN, p. 25). Choices are:  
ALL - All the Ports which have been set Accessible (see SET ACCESSIBLE  
PORTS, p. 24);  
POWERED ON - Only those Ports which have been set Accessible and  
are Powered On;  
QUICK VIEW - Only those Ports which have been set Accessible and have  
been selected as Quick View Ports (see SET QUICK VIEW PORTS, p. 24);  
QUICK VIEW + POWERED ON - Only those Ports which have been set  
Accessible and have been selected as Quick View Ports and are Powered On.  
The default is ALL.  
Note: The Quick View choices only show up on an Administrators screen, since  
only he has Quick View setting rights (see SET QUICK VIEW PORTS, p. 24,  
for details).  
SCREEN BLANKER  
If there is no input from the console for the amount of time set with this  
function, the screen is blanked. Key in a value from 1 - 30 minutes, then press  
[Enter]. A setting of 0 disables this function. The default is 0 (disabled).  
HOTKEY COMMAND Enables / Disables the Hotkey Command function in case a  
MODE  
conflict with programs running on the computers occurs. The default enabled.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OSD Operation (continued)  
OSD Functions  
F4 ADM  
F4 is a Super Administrator and Administrator only function. It allows them to configure and control the  
overall operation of the OSD. To change a setting Double Click it; or use the Up and Down Arrow Keys to  
move the highlight bar to it then press [Enter].  
After you select an item, a submenu with further choices appears. Double Click the choice you want, or  
move the Highlight Bar to it then press [Enter]. An icon appears before the selected choice to indicate  
which one it is. The settings are explained in the following table:  
Note: All your setting changes are stored in temporary memory and remain in effect for the duration of your  
session. The changes only become permanent when you Log out of the OSD (see p. 26). If you shut down  
the B060 Series KVM without first logging out, your changes are discarded.  
Setting  
Function  
SET USERNAME & PASSWORD This function is used to set Usernames and Passwords:  
1. One Super Administrator, one Administrator, and four User  
passwords can be set.  
2. After you key in a name for the Super Administrator,  
Administrator, or User, a screen that allows you to key in the  
username and password appears. The username and password  
may be up to 15 characters long, and can consist of any  
combination of letters and numbers (A - Z, 0 - 9).  
3. For each individual, key in the Username and Password, then  
press [Enter].  
4. To modify or delete a previous Username and/or Password, use  
the backspace key to erase individual letters or numbers.  
SET LOGOUT TIMEOUT  
If there is no input from the console for the amount of time  
set with this function, the Operator is automatically logged out. A  
login is necessary before the console can be used again.  
This enables other Operators to gain access to the computers when  
the original Operator is no longer accessing them, but has forgotten  
to log out. To set the timeout value, key in a number from 1 - 180  
minutes, then press [Enter]. If the number is 0 [zero], this function  
is disabled.  
The default is 0 (disabled).  
EDIT PORT NAMES  
To help identify which computer is attached to a particular port,  
every port can be given a name. This function allows the  
Administrator to create, modify, or delete port names.  
To Edit a port name:  
1. Click the desired port, or use the Navigation Keys to highlight  
the choice. Press [Enter].  
2. Key in the new Port Name, or modify/delete the old one. The  
maximum number of characters allowed for the Port Name is 15.  
Legal characters include:  
• All alpha characters: a - z; A - Z  
• All numeric characters: 0 - 9,_  
+ - / : . and Space  
Case does not matter; the OSD displays the Port Name in all  
capitals no matter how they were keyed in.  
3. When you have finished editing, press [Enter] to have the change  
take effect. To abort the change, press [Esc].  
RESTORE DEFAULT VALUES  
This function is used to undo all changes and return the setup to the  
original factory default settings (see FACTORY DEFAULT SETTINGS,  
p. 35) - except for the Names settings that were assigned to the  
Ports, which are saved.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OSD Operation (continued)  
CLEAR THE NAME LIST  
This is similar to Restore Default Values. The difference is that it  
also clears the Names settings along with undoing all changes and  
returning the setup to the original factory default setting.  
Choices are Y (for Yes), or N (for No). When activated, the beeper  
sounds whenever a Port is changed; when activating the Auto Scan  
function (see F7 SCAN, p. 25); or an invalid entry is made on an  
OSD menu. The default is Y (activated).  
ACTIVATE BEEPER  
SET QUICK VIEW PORTS  
This function lets the Administrator select which Ports to include  
as Quick View ports.  
• To select/deselect a port as a Quick View Port, Double Click the  
port you want, or use the Navigation Keys to move the highlight  
bar to it, then press [Enter].  
• When a port has been selected as a Quick View Port, an arrowhead  
displays in the QV column of the LIST on the Main Screen to  
indicate so. When a port is deselected, the arrowhead disappears.  
• If one of the Quick View options is chosen for the LIST view  
(see F2 LIST, p. 21), only a Port that has been selected here will  
display on the List.  
• If one of the Quick View options is chosen for Auto Scanning  
(see SCAN/SKIP MODE, p. 22), only a Port that has been  
selected here will be Auto Scanned. The default is for no ports to  
be selected.  
SET ACCESSIBLE PORTS  
This function lets the Administrator define Operator access to the  
computers on the installation on a Port-by-Port basis.  
For each Operator, select the target Port; then press the [Spacebar]  
to cycle through the choices: F (Full access), V (View Only), or  
blank (No access). Repeat until all access rights have been set, then  
press [Enter]. The default is F for all users on all Ports.  
Note: A blank setting means that no access rights are granted. The  
Port will not show up on the User's LIST on the Main Screen.  
If there is no input from the console accessing a particular port for  
the amount of time set with this function, the port is released,  
allowing it to be accessed by the other consoles.  
SET ACCESS TIMEOUT  
To set the timeout value, key in a number from 0 - 255 seconds,  
then press [Enter].  
If the number is 0 [zero], this function is disabled. The default is  
5 seconds.  
SET KEYBOARD LANGUAGE  
SET OPERATING PLATFORM  
BUS AUTHORIZATION  
This function allows the Administrator to define the keyboard  
language layout for each port. To assign a keyboard language,  
select the target port; then press the [Spacebar] to cycle through  
the choices: US English; Japanese; or French.  
The default is US English.  
This allows the Administrator to define the operating platform for  
the system connected to each port. To assign an operating platform,  
select the port; then press the [Spacebar] to cycle through the  
choices: Windows (PC compatible); Mac; and Sun.  
The default is Windows (PC compatible).  
This function allows the Super Administrator to authorize Operator  
access to Stations on the installation other than the ones connected  
to the Station the Operator is logged in on.  
For each Operator, press the [Spacebar] to cycle through the  
choices: F (Full access), V (View Only), or blank (No access).  
Repeat until all access rights have been set, then press [Enter].  
The default is blank - No Operators have access rights to  
other Stations (and the computers connected to them).  
In order to upgrade the B060 Series KVM’s firmware, you must  
invoke Firmware Upgrade Mode with this setting. Only the Super  
Administrator on the Master Station can use this function.  
FIRMWARE UPGRADE  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OSD Operation (continued)  
OSD Functions  
F5 SKP  
This function enables you to easily skip backward or forward - switching the console focus from the cur-  
rently active computer port to the previous or next available one.  
• The selection of computers to be available for Skip Mode switching is made with the Scan/Skip  
Mode setting under the F3 SET function (see p. 21).  
• When you are in Skip Mode, press [] to switch to the previous computer in the List; press [] to  
switch to the next computer in the List; press [] to switch to the last computer on the previous sta-  
tion in the List; press [] to switch to the first computer on the next station in the List.  
Note: When you Skip, you only Skip to the previous or next available computer that is in the  
Scan/Skip Mode selection (see p. 22).  
• When the focus switches to a Port that has been selected for Scan/Skip Mode, a Left/Right Triangle  
symbol appears before its Port ID Display.  
• While Skip Mode is in effect, the console will not function normally. You must exit Skip Mode in  
order to regain control of the console.  
• To exit Skip Mode, press [Spacebar] or [Esc].  
F6 BRC  
F6 is a Super Administrator or Administrator only function. Clicking the F6 field, or pressing [F6], invokes  
Broadcast (BRC) Mode. When this function is in effect, commands sent from the  
console are broadcast to all available computers on the installation.  
This function is particularly useful for operations that need to be performed on multiple computers, such as  
performing a system wide shutdown, installing or upgrading software, etc.  
BRC works in conjunction with the F2 LIST function. The LIST function (see p. 21), is used to broaden or  
narrow the focus of which Ports appear on the OSD Main Screen. When you Broadcast a command, it only  
goes to the Ports currently selected to be listed on the OSD Main Screen.  
• While BRC Mode is in effect, a Speaker symbol appears before the Port ID Display of the port that  
currently has the console focus.  
• While BRC Mode is in effect, the mouse will not function normally. You must exit BRC Mode in  
order to regain control of the mouse.  
• To exit BRC Mode, invoke the OSD (with the OSD Hotkey), then Click the F6 field, or press [F6],  
to turn BRC Mode off.  
F7 SCAN  
This function allows you to automatically switch among the available computers at regular intervals so that  
you can monitor their activity without having to take the trouble of switching yourself.  
• The selection of computers to be included for Auto Scanning is made with the Scan/Skip Mode set-  
ting under the F3 SET function (see p. 21).  
• The amount of time that each Port displays for is set with the Scan Duration setting under the F3  
SET function (see p. 21). When you want to stop at a particular location, press the [Spacebar] or  
[Esc] to stop scanning and exit Auto Scan Mode.  
• If the scanning stops on an empty port, or one where the computer is attached but is powered Off,  
the monitor screen will be blank, and the mouse and keyboard will have no effect. Simply wait—  
after the Scan Duration time is up, the Scan function will move on to the next port.  
• As each computer is accessed, an S appears in front of the Port ID display to indicate that it is being  
accessed under Auto Scan Mode.  
• While Auto Scan Mode is in effect, the console will not function normally. You must exit Auto Scan  
Mode in order to regain control of the console.  
• While you are in Auto Scan Mode, you can pause the scanning in order to keep the focus on a par-  
ticular computer either by pressing P, or with a Left Click of the mouse. See Invoking Auto Scan, p.  
30, for details.  
• To exit Auto Scan Mode, press the [Spacebar] or [Esc].  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OSD Operation (continued)  
OSD Functions  
F8 LOUT  
LOUT (Log Out) logs you out of OSD control of the computers, and blanks the Console screen. This is  
different from simply pressing [Esc] to deactivate the OSD when you are at the Main Screen. With this  
function you must log in all over again to regain access to the OSD, whereas with [Esc], all you have to do  
to reenter the OSD is tap the OSD Hotkey.  
Note: 1 When you reenter the OSD after logging out, the screen stays blank except for the OSD  
Main Screen. You must input your password before you can continue.  
2. If you re-enter the OSD after logging out, and immediately use [Esc] to deactivate the OSD with-  
out having selected a port from the OSD menu, a Null Port message displays on the screen. The  
OSD Hotkey will bring up the Main OSD Screen.  
Cascaded OSD Operation  
Under Protocol Interface Cascading (see p. 12), the OSDs of the cascaded switches are all seamlessly  
integrated into the B060 Series KVM's OSD so that all ports can be accessed from there.  
Under Physical Interface Cascading (see p. 13), however, there are two separate OSDs: one for the  
B060 Series KVM, and one for the cascaded switch.  
If both the B060 Series KVM and the cascaded switch use the same OSD Hotkey ([Scroll Lock] [Scroll  
Lock], for example), both OSDs show up on the console monitor when you invoke the OSD.  
The B060 Series KVM’s OSD is on top, overlaying the OSD of the cascaded switch. To proceed, select the  
port that the cascaded switch is connected to on the B060 Series KVM’s OSD. The B060 Series KVM's  
OSD disappears, leaving the cascaded switch’s OSD for you to work with.  
You can eliminate this problem by selecting the alternate OSD Hotkey ([Ctrl] [Ctrl]) for the cascaded  
switch (see the switch’s User Manual for details). With this method when you press [Scroll Lock] [Scroll  
Lock], only the B060 Series KVM’s OSD comes up. To proceed:  
1. Select the port that the cascaded switch is connected to. The B060 Series KVM’s OSD disappears.  
2.Tap [Ctrl] [Ctrl] to bring up the cascaded switch's OSD for you to work with.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hotkey Operation  
Hotkey Port Control  
Hotkey Port Control allows you to provide KVM focus to a particular computer directly from the keyboard.  
Note: Hotkeys work best in single stage and basic cascaded or daisy chained installations. For complicated  
daisy chain+cascaded installations, it is simpler, more convenient and more efficient to use the OSD.  
The B060 Series KVM provides the following Hotkey Port Control features:  
• Selecting the Active Port  
• Auto Scanning  
• Skip Mode Switching  
Invoking Hotkey Mode  
All Hotkey operations begin by invoking the Hotkey Mode (HKM). Invoking the Hotkey Mode takes three  
steps:  
1. Hold down the Num Lock key;  
2. Press the * key;  
3. Simultaneously release both keys:  
[Num Lock] + [*]  
or  
[Num Lock] + [-]  
When the Hotkey Mode is active:  
• The Caps Lock, and Scroll Lock LEDs flash in succession to indicate so. They stop flashing and revert  
to normal status when you exit the Hotkey Mode.  
• A Command Line appears at the bottom of the monitor screen. The command line prompt is the word  
Hotkey: in white text on a blue background. Text that you key in while in the Hotkey Mode displays  
here.  
• Ordinary keyboard and mouse functions are suspended - only Hotkey compliant keystrokes and mouse  
clicks (described in the sections that follow), can be input.  
• Pressing [Esc] or [Spacebar] exits the Hotkey Mode.  
Selecting the Active Port  
Each CPU port is assigned a Port ID (see Port ID Numbering, p. 17). You can directly access any computer  
on the installation with a Hotkey combination that specifies the Port ID of the CPU Port that the computer  
is connected to. The steps involved are:  
1. Invoke Hotkey Mode (see above).  
2. Key in the Port ID. The Port ID numbers display on the Command Line as you key them in.  
If you make a mistake, use [Backspace] to erase the wrong number.  
3. Press [Enter]  
After you press [Enter], the KVM focus switches to the designated computer and you automatically exit  
Hotkey Mode.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hotkey Operation (continued)  
Auto Scanning  
Auto Scan switches among all the CPU Ports that are accessible to the current Operator at regular intervals  
(see Scan/Skip Mode, p. 22, for information regarding accessible ports). This function is  
convenient for automatically monitoring the activity of the computers on the installation.  
Setting the Scan Interval: The amount of time Auto Scan dwells on each port is set with the Scan  
Duration setting of the OSD F3 SET function (see p. 21). You can change the scan interval before  
activating Hotkey Auto Scanning, if you wish, with the following Hotkey combination:  
1. Invoke the Hotkey Mode (see p. 27).  
2. Key in [T] [n]  
Where [T] is the letter T, and [n] is a number from 1-255 that represents the number of seconds for  
the dwell time. The letter T and the numbers display on the Command Line as you key them in. If  
you make a mistake, use [Backspace] to erase the wrong number.  
3. Press [Enter]  
After you press [Enter], you automatically exit the Hotkey Mode, and are ready to invoke Auto Scanning.  
Invoking Auto Scan:  
To start Auto Scanning, key in the following Hotkey combination:  
1. Invoke the Hotkey Mode (see p. 27).  
2. Press [A].  
After you press A, you automatically exit the Hotkey Mode, and enter Auto Scan Mode, and Auto  
Scanning begins.  
• While you are in Auto Scan Mode, you can pause the scanning in order to keep the focus on a  
particular computer either by pressing P or with a Left Click of the mouse. During the time that  
Auto Scanning is paused, the Command Line displays: Auto Scan: Paused.  
Pausing and Exiting are the two ways to stop scanning and keep the focus on a particular computer. If  
you intend to continue scanning after a brief stop, Pausing is more convenient than Exiting Auto Scan  
Mode completely. This is because when you Resume scanning after Pausing, you start from where  
you left off. On the other hand, if you Exit and then Restart Auto Scan, you start over from the very  
first computer on the installation.  
To Resume Auto Scanning after you Pause, press any key or Left Click. Scanning continues from  
where it left off.  
• While Auto Scan Mode is in effect, ordinary keyboard and mouse functions are suspended—only  
Auto Scan Mode compliant keystrokes and mouse clicks can be input. You must exit Auto Scan  
Mode in order to regain normal control of the console.  
3. To exit Auto Scan Mode press [Esc] or [Spacebar]. Auto Scanning stops when you exit Auto Scan  
Mode.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hotkey Operation (continued)  
Skip Mode  
This feature allows you to switch between computers in order to monitor them manually. In contrast to  
Auto Scanning, which automatically switches after a fixed interval, Skip Mode lets you dwell on a particular  
port for as long as you like. To invoke Skip Mode, key in the following Hotkey combination:  
1. Invoke Hotkey Mode (see p. 27).  
2. Key in [Arrow]  
• Where [Arrow] refers to one of the Arrow keys. After you press [Arrow], you automatically exit  
HKM, and enter Skip Mode where you can switch ports as follows:  
Skips from the current port to the first accessible port previous to it. (See Scan/Skip Mode,  
p. 22, for information regarding accessible ports.)  
Skips from the current port to the next accessible port.  
Skips from the current port to the last accessible port of the previous Station.  
Skips from the current port to the first accessible port of the next Station.  
• Once you are in Skip Mode, you can keep on skipping by pressing the Arrow keys. You don't have  
to use the [NumLock] + [*] combination each time you want to skip.  
• While Skip Mode is in effect, ordinary keyboard and mouse functions are suspended - only Skip  
Mode compliant keystrokes can be input. You must exit Skip Mode in order to regain normal con-  
trol of the console.  
3. To exit Skip Mode, press [Esc] or [Spacebar].  
Hotkey Beeper Control  
The Beeper (see Activate Beeper, p. 24) can be Hotkey toggled On and Off. To toggle the Beeper, key in  
the following Hotkey combination:  
1. Invoke Hotkey Mode (see p. 27).  
2. Press [B]  
After you press B, the Beeper toggles On or Off. The Command Line displays Beeper On or Beeper Off for  
one second; then the message disappears and you automatically exit the Hotkey Mode.  
Hotkey Summary Table  
[Num Lock] + [*] [Port ID] [Enter] Switches access to the computer that corresponds to that Port ID.  
or  
[Num Lock] + [-] [T] [n] [Enter] Sets the Auto Scan interval to n seconds- where n is a number from  
1 - 255.  
[A]  
Invokes Auto Scan Mode.  
When Auto Scan Mode is in effect, [P] or Left Click pauses Auto  
Scanning.  
When Auto Scanning is paused, pressing Any Key or another Left  
Click resumes Auto Scanning.  
[]  
[]  
[]  
Invokes Skip Mode and Skips from the current port to the first  
accessible port previous to it.  
Invokes Skip Mode and Skips from the current port to the next  
accessible port.  
Invokes Skip Mode and Skips from the current port to the last  
accessible port of the previous Station.  
[]  
Invokes Skip Mode and Skips from the current port to the first  
accessible port of the next Station.  
[B]  
Toggles the Beeper On or Off.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Multiplatform Support  
The B060 Series KVM provides the utmost in flexibility for your installation by offering multi-platform  
support. Through the use of Console Modules and KVM Adapter Cables, PS/2 and USB interfaces can be  
mixed and matched at the console side, and PS/2, USB and Sun interfaces can be mixed and matched at  
the computer side. With this approach, either type of console can access and control multiple computer  
types - PC compatible, Sun and Mac.  
The PC Compatible (101/104 key) keyboard can emulate the functions of the Sun Mac keyboards. The  
corresponding functions are shown in the tables on the following pages.  
Mac Keyboard Emulation  
Sun Keyboard Emulation  
Pc Keyboard  
[SHIFT]  
Mac Keyboard  
Pc Keyboard  
[Ctrl] [T]  
[Ctrl] [F2]  
[Ctrl] [F3]  
[Ctrl] [F4]  
[Ctrl] [F5]  
[Ctrl] [F6]  
[Ctrl] [F7]  
[Ctrl] [F8]  
[Ctrl] [F9]  
[Ctrl] [F10]  
[Ctrl] [1]  
[Ctrl] [2]  
[Ctrl] [3]  
[Ctrl] [4]  
[Ctrl] [H]  
App  
Sun Keyboard  
Stop  
Shift  
Ctrl  
[Ctrl]  
Again  
Props  
Undo  
[Win]  
[Ctrl] [1]  
Mult  
V_DN  
V_UP  
[Ctrl] [2]  
Front  
[Ctrl] [3]  
Copy  
[Ctrl] [4]  
Open  
[Alt]  
L Alt/Option  
F13  
Paste  
[Prt_Sc]  
Find  
[Scroll Lock]  
[Desktop Menu]  
[Enter]  
F14  
Cut  
=
Return  
Delete  
Help  
[Back Space]  
[Ins]  
[Ctrl] [Desktop Menu]  
F15  
Help  
Compose  
Note: When using key combinations, press and  
release the first key (Ctrl or Alt), then press and  
release the activation key.  
Win Key  
Note: When using [Ctrl] combinations, press and  
release the Ctrl key, then press and release the activa-  
tion key.  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Firmware Upgrade Utility  
Introduction  
Purpose  
The purpose of the Windows-based Firmware Upgrade Utility (FWUpgrade.exe) is to provide an automated  
process to make upgrading the KVM switch’s firmware as smooth and painless as possible.  
The program comes as part of a Firmware Upgrade Package that is specific for each device.  
As new firmware revisions become available, new firmware upgrade packages are posted on our web site:  
Check the web site regularly to find the latest information and upgrade packages.  
Before You Begin  
To prepare for the firmware upgrade, do the following:  
1. From a computer that is not part of your KVM installation go to our Internet support site and  
choose the model name that relates to your device to get a list of available Firmware Upgrade  
Packages.  
2. Choose the Firmware Upgrade Package you want to install (usually the most recent), and  
download it to your computer.  
3. Use Cat5e cable to connect the B060 Series KVM’s Firmware Upgrade Port to a hub connected to  
the computer you used in Step 1.  
Note: On a daisy chained installation, connect the cable to the First Station unit. The chained  
stations will receive the upgrade via the daisy chain cables.  
4. Shut down all of the computers - but not the Stations - on your KVM installation.  
5. From your KVM switch console, bring up the OSD and select the F4ADM function.  
6. Scroll down to FIRMWARE UPGRADE. Press [Enter], then press [Y] to invoke Firmware  
Upgrade Mode.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
The Firmware Upgrade Utility (continued)  
Performing the Upgrade  
Starting the Upgrade  
To upgrade your firmware:  
1. To run the downloaded Firmware Upgrade Package file, either double click the file icon, or open a  
command line and enter the full path to it. The Firmware Upgrade Utility Welcome screen appears.  
2. Read and Agree to the License Agreement (enable the I Agree radio button).  
3. Click Next to continue. The Firmware Upgrade Utility main screen appears:  
The Utility inspects your installation. The devices capable of being upgraded by the package are  
listed in the Device List panel.  
Note: 1. Although only one device type is shown in the list (B062-001-PS2, for example), all  
units of that type receive the upgrade.  
2. B060-016-2U or B060-032U refers to the first station in a daisy-chained configuration;  
B060-016-2N or B060-032N refers to the chained stations.  
3. A blue background behind the device name indicates that it is ready to be upgraded.  
4. When the list is complete, click Next to start the upgrade.  
• If you enabled Check Firmware Upgrade, the Utility compares the devices  
firmware level with that of the upgrade files. If it finds that the devices version  
is higher, it brings up a dialog box informing you of the situation and gives you  
the option to Continue or Cancel.  
• If you didnt enable Check Firmware Upgrade, the Utility installs the upgrade  
files without checking their version level.  
• While a device group is being upgraded, the background behind its name  
changes to green and blinks on and off to indicate that upgrading for that device  
group is in progress.  
• As the Upgrade proceeds, status messages appear in the Status Messages panel,  
and the progress toward completion is shown on the Progress bar.  
• As each device update completes, its status is reported in the Status Messages  
panel.  
• When a device group upgrade is successful, the background behind the device  
group name changes to pink; if a member of a device group fails to upgrade  
successfully, the background behind the device group name changes to red to  
indicate an upgrade failure in the group. Check the Status Messages to ascertain  
which device failed to upgrade.  
5. When the upgrade for all the devices is done, click Finish to close the Utility.  
Upgrade Failure  
If the upgrade fails to complete successfully for all devices:  
1. Click Finish to close the Firmware Upgrade Utility.  
2. Start the firmware upgrade procedure again (see above).  
3. When the Device List is complete, Click on the device group that the failed device belongs to in  
the Device List panel (see above).  
4. Click Next to start the upgrade.  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix  
Connection Tables  
The following tables indicate the relationship between the number of KVM units and the number of  
computers that they control:  
B060-016-2 Daisy-Chain  
B060-032 Daisy Chain  
B060-016-2  
Computers  
1-16  
B060-032s  
Computers  
1 - 32  
33 - 64  
65 - 96  
97 -128  
129 - 160  
161 - 192  
193- 224  
225 - 256  
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
17-32  
33-48  
49-64  
65-80  
81-96  
97-112  
113-128  
B060-032 Cascade to Tripp Lite B007-008  
KVMs Computers KVMs Computers KVMs Computers  
KVMs Computers  
1
2
3
4
5
6
7
8
32 - 39  
40 - 46  
47 - 53  
54 - 60  
61 - 67  
68 - 74  
75 - 81  
82 - 88  
9
89 - 95  
96 - 102  
17  
18  
19  
20  
21  
22  
23  
24  
145 - 151  
152 - 158  
159 - 165  
166 - 172  
173 - 179  
180 - 186  
187 - 193  
194 - 200  
25  
26  
27  
28  
29  
30  
31  
32  
201 - 207  
208 - 214  
215 - 221  
222 - 228  
229 - 235  
236 - 242  
243 - 249  
250 - 256  
10  
11  
12  
13  
14  
15  
16  
103 - 109  
110 - 116  
117 - 123  
124 - 130  
131 - 137  
138 - 144  
B060-016-2 Cascade to Tripp Lite B007-008  
KVMs Computers KVMs Computers KVMs Computers  
KVMs Computers  
1
2
3
4
32 - 39  
40 - 46  
47 - 53  
54 - 60  
5
6
7
8
61 -74  
68 - 74  
75 - 81  
82 - 88  
9
88 - 95  
96 - 102  
103 - 109  
110 - 116  
13  
14  
15  
16  
117 - 123  
124 - 130  
131 - 137  
138 - 144  
10  
11  
12  
OSD Factory Default Settings  
The factory default settings are as follows:  
Setting  
Default  
OSD Hotkey  
[Scroll Lock] [Scroll Lock]  
Upper Left Corner  
3 Seconds  
The Port Number plus the Port Name  
5 Seconds  
Port ID Display Position  
Port ID Display Duration  
Port ID Display Mode  
Scan Duration  
Scan/Skip Mode  
Screen Blanker  
Hotkey Command Mode  
Logout Timeout  
Beeper Y  
All  
0 (Disabled)  
Enabled  
0 (Disabled)  
(Activated)  
Quick View Ports  
Accessible Ports  
Access Timeout  
No ports selected  
F (Full) For all Users on all Ports  
5 seconds  
Keyboard Language Operating Platform PC compatible  
Bus Authorization Blank - No Operators have access rights  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Appendix (continued)  
OSD Factory Default Settings  
Clear Login Information  
If you are unable to perform an Administrator login (because the Username and Password information has  
become corrupted, or you have forgotten it, for example), you can clear the login information with the  
following procedure:  
1. Power off the switch and remove the top cover of the switch module case.  
2. Short the jumper labeled Default Password at the right front of the switch’s main board.  
3. Power on the switch.  
When you power the switch on, the following message appears on the LCD display:  
USERNAME AND PASSWORD INFORMATION HAS BEEN CLEARED. PLEASE  
POWER OFF THE SWITCH, REMOVE THE JUMPER, CLOSE THE CASE, THEN  
RESTART.  
4. After you start back up, the OSD login function acts exactly the way it did the first time the switch  
was run (see p. 20) and you can reset passwords for the Administrators and Users.  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
Function  
Computer Connections Direct  
Max  
Specification B060-032  
32  
256 (via 8 level daisy chain)  
256 (via 2 level cascade)  
Specification B060-016-2  
16  
128 (via 8 level daisy chain)  
128 (via 2 level cascade)  
2,048 (via 8 level daisy chain  
+ 2 level cascade)  
1,024 (via 8 level daisy chain  
+ 2 level cascade)  
Console Connections  
Port Selection  
4 Direct; 32 Max.  
(via 8 level daisy chain)  
OSD (On Screen Display);  
Hotkeys  
2 Direct; 16 Max.  
(via 8 level daisy chain)  
OSD (On Screen Display);  
Hotkeys  
LEDs  
On Line/Selected  
Power  
32 dual colored (Green / Red)  
1 (Blue)  
16 dual colored (Green / Red)  
1 (Blue)  
Station ID  
Computers  
Consoles  
Daisy Chain  
2 x 7 segments (Yellow)  
32 x RJ-45 F  
4 x RJ-45 F  
2 x 7 segments (Yellow)  
16 x RJ-45 F  
2 x RJ-45 F  
Connectors  
2 x HDB-60 F  
2 x HDB-60 F  
Firmware Upgrade 1 x RJ-45 F  
1 x RJ-45 F  
Power  
Reset  
Power  
1 x Full Range AC Power Port  
1 x Pushbutton (semi-hidden)  
1 x Rocker  
1 x Full Range AC Power Port  
1 x Pushbutton (semi-hidden)  
1 x Rocker  
Switches  
F/W Upg. Recover 1 x Slide  
1 x Slide  
Keyboard/Mouse Emulation  
Scan Interval  
PS/2; Sun; USB (PC, Sun, Mac)  
0 - 255 secs.  
PS/2, Sun; USB (PC, Sun, Mac)  
0 - 255 secs.  
Power Consumption  
Video  
120V - 230V  
1024 x 768 @ 150m; DDC2B  
120V - 230V  
1024 x 768 @ 150m; DDC2B  
Environment  
Operating Temperature:  
32 - 120° F  
Operating Temperature:  
32-120° F  
Storage Temperature: -  
4 - 140° F  
4-140° F  
Humidity: 0 - 80% RH, NC  
Metal  
Humidity: 0-80% RH, NC  
Metal  
Housing  
Weight  
8.75 lbs  
7.75 lbs.  
Dimensions  
(L x W x H)  
(L x W x H)  
17 x 10 x 1.75 inches  
17 x 10 x 1.75 inches  
Console Interface Modules  
Function  
Connectors Console Keyboard  
Console Mouse  
B062-001-PS2  
1 x mini-DIN-6 F  
1 x mini-DIN-6 F  
B062-001-USB  
1 x USB Type A  
1 x USB Type A  
Console Monitor  
1 x HDB-15 F  
Link to B060 series  
Power  
1 x RJ-45 F  
1 x DC 5V  
1 (Amber)  
1 (Green)  
LEDs  
On Line  
Link  
Switches  
1 x Slide (FW Upgrade Recovery)  
Server Interface Modules  
Function  
B054-001-PS2  
1 x mini-DIN-6 M  
1 x mini-DIN-6 M  
B054-001-SUN  
1 x USB Type A  
1 x USB Type A  
1 x HB15 M  
B054-001-USB  
1 x USB Type A  
1 x USB Type A  
Connectors  
Keyboard  
Mouse  
Monitor  
Link to B060 series  
On Line  
1 x RJ-45 F  
1 (Amber)  
LEDs  
Link  
1 (Green)  
Switches  
1 x Slide (FW Upgrade Recovery)  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
Symptom  
Possible Cause  
Action  
Operator can only access one port  
on a cascaded KVM. Cannot switch to  
any of the other ports  
The cascaded KVM’s  
display channel is being  
occupied by a previous user  
There is only one display  
channel for all the ports  
on a cascaded KVM  
switch. The previous  
operator’s access timeout  
expired, so the port is  
released, but his logout  
timeout has not expired so  
the display channel has  
not been released.  
To avoid this problem, be  
sure to set a reasonable  
logout timeout, for all users.  
FCC Radio/TV Interference Notice  
Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the  
FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is  
operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not  
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required  
to correct the interference at his own expense. The user must use shielded cables and connectors with this product. Any  
changes or modifications to this product not expressly approved by the party responsible for compliance could void the  
user’s authority to operate the equipment.  
Warranty Registration  
entered into a drawing for a chance to win a FREE Tripp Lite product!*  
* No purchase necessary. Void where prohibited. Some restrictions apply. See website for details.  
1-Year Limited Warranty  
TRIPP LITE warrants its products to be free from defects in materials and workmanship for a period of one (1) year from  
the date of initial purchase. TRIPP LITE's obligation under this warranty is limited to repairing or replacing (at its sole  
option) any such defective products. To obtain service under this warranty, you must obtain a Returned Material  
Authorization (RMA) number from TRIPP LITE or an authorized TRIPP LITE service center. Products must be returned to  
TRIPP LITE or an authorized TRIPP LITE service center with transportation charges prepaid and must be accompanied by  
a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to  
equipment which has been damaged by accident, negligence or misapplication or has been altered or modified in any way.  
EXCEPT AS PROVIDED HEREIN, TRIPP LITE MAKES NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING  
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some states do not permit  
limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.  
EXCEPT AS PROVIDED ABOVE, IN NO EVENT WILL TRIPP LITE BE LIABLE FOR DIRECT, INDIRECT,  
SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT,  
EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, TRIPP LITE is not liable for any costs,  
such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substi-  
tutes, claims by third parties, or otherwise.  
Tripp Lite World Headquarters  
1111 W. 35th Street, Chicago, IL 60609 USA  
200707049 93-2707  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tiffen Camera Accessories Soft FX Warm Soft FX Filters User Manual
TOA Electronics Home Security System N VR2010 User Manual
Toastmaster Convection Oven E9451 HP12CDNF User Manual
Toshiba Fax Machine 2040C User Manual
Toshiba Home Security System FS 3600 User Manual
Transcend Information MP3 Player Tsonic 840 User Manual
Tripp Lite TV Cables A004 006 User Manual
TV Ears Clothes Dryer DRI DOCK User Manual
Uniden Cordless Telephone ANA 9500 User Manual
Vantec Laptop NBL S100 User Manual