Trion Air Cleaner FM 1000E User Manual

FM 1000  
ELECTRONIC / MEDIA AIR CLEANERS  
Delivering Clean Air to Public Places  
The Trion FM 1000 was specifically designed to  
clean the air in rooms where people work or relax,  
such as restaurants, bars, taverns, offices, conference  
or computer rooms, waiting rooms, or designated  
smoking areas. Because of its smart design, it fits in a  
2' x 4' (610 x 1219 mm) ceiling panel, so its an easy  
solution for most any situation.  
The FM 1000 Provides:  
• Multiple Model Selection — There are two models to choose from: the FM 1000E  
(electronic air cleaner) and the FM 1000M (media air cleaner). So, theres an  
FM 1000 that can meet virtually any scenario.  
• Easy Installation — These units feature a low-profile design that is not only appealing  
to the eye, but requires no elaborate ductwork or installation.  
• High Performance — Each of these units is capable of removing up to 95% of tobacco  
smoke, dust, pollen, lint, bacteria, and mold spores from indoor air.  
• Flexible Performance — Each unit features three convenient speeds, ranging from  
3
400 to 1100 cfm (680 – 1879 m /hr) to quickly and easily meet the demands of the  
environment.  
Affordable Operation — Because these units recirculate indoor air, theres no expense  
to reheat or cool air. And the FM 1000E features a Forever Filter® that never needs to  
be replaced; just clean, dry, and reinstall.  
Additional Odor Control — The optional charcoal after-filter helps control the smell of  
gas and other odors.  
• Super-Effective Air Cleaning — The optional remote discharge allows wider separation  
between intake and discharge areas. This means more effective air cleaning.  
Powerfully-Effective  
Airflow Pattern  
The FM 1000E and FM 1000M models feature  
“center suction” dirty air intake and discharge  
returned clean air in six directions, so clean air  
circulates faster. That means happier, more  
comfortable patrons, employees, or guests.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FM 1000 DIMENSIONS  
POSITIONING BRACKET  
& FILLER STRIP  
AIR  
FLOW  
AIR  
INLET  
AIR  
FLOW  
TOP  
.50”  
(13 mm)  
TYP.  
22.88”  
(581 mm)  
KNOCKOUTS FOR  
2.75”  
POWER CONNECTION  
(70 mm)  
1.50”  
(38 mm)  
47.25”  
(1200 mm)  
7/8” (22 mm) DIA.  
AIR  
FLOW  
AIR  
FLOW  
19.63”  
(499 mm)  
SIDE  
1.125”  
(29 mm)  
8.00”  
(203 mm)  
POSITIONING  
BRACKET  
2 REQ’D @ EACH END  
POSITIONING  
BRACKET  
2 REQUIRED  
FIELD WIRING  
COMPARTMENT  
COVER  
REMOTE DISCHARGE OPTION  
2.75”  
(70 mm)  
KNOCKOUTS FOR  
POWER CONNECTION 5.38”  
1.50”  
137 mm  
7/8” (22 mm) DIA.  
0.54”  
(38 mm)  
2.90”  
(74 mm)  
(14 mm)  
10.00”  
DIA.  
19.63”  
(499 mm)  
1.125”  
(29 mm)  
8.00”  
(203 mm)  
POSITIONING  
BRACKET  
POSITIONING  
BRACKET  
2 REQ’D @  
EACH END  
12.25”  
2 REQUIRED  
(311 mm)  
24.25” (616 mm)  
AIR  
FLOW  
25.08” (637 mm)  
AIR  
AIR  
INLET  
FLOW  
AIR  
FLOW  
22.88”  
(581 mm)  
AIR  
FLOW  
AIR  
FLOW  
AIR  
FLOW  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FM 1000 ELECTRONIC / MEDIA AIR CLEANERS SPECIFICATIONS  
MODEL  
FM 1000E ELECTRONIC  
FM 1000M MEDIA  
PART NO.  
440515-001  
47 1/2 L x 22 7/8 W x 19 5/8 D (1207 x 581 x 499)  
Above ceiling / flush mount  
440515-002  
47 1/2 L x 22 7/8 W x 19 5/8 D (1207 x 581 x 499)  
Above ceiling / flush mount  
DIMENSIONS  
INCHES (mm)  
INSTALLATION  
WEIGHT  
LBS (kg)  
108 (49) / shipping 240 (109)  
88 (40) / shipping 160 (72.6)  
ELECTRICAL  
MOTOR  
120 V, 60 Hz, 1 ph - 3.1 amps  
120 V, 60 Hz, 1 ph - 4.0 amps  
1/3 hp (.25 kW) ball bearing, direct drive, thermally protected  
1/3 hp (.25 kW) ball bearing, direct drive, thermally protected  
BLOWER  
Propeller fan  
Propeller fan  
3
3
AIR VOLUME  
CONTROLS  
600, 800, 1100 cfm  
(1020, 1360, 1870 m  
/hr)  
400, 500, 650 cfm  
(680, 850, 1105 m  
/hr)  
3-speed, power “ON” light, “to cell” light  
49, 56, 65 dB  
3-speed, power “ON” light  
SOUND RATING  
FILTER EFFICIENCY  
PRE-FILTER  
55, 64, 69 dB  
95% per ASHRAE 52.1 / dust spot  
Aluminum mesh  
Up to 95% per ASHRAE 52.1 / dust spot  
Aluminum mesh  
PRIMARY FILTER  
Forever Filter® – permanent aluminum collector cell  
Multi-pleat ꢀlter module  
Standard Speciꢀcations For Each Unit  
CABINET  
20-Gauge (1.0 mm) galvanized steel  
Almond epoxy powder-coat paint  
6-Way discharge, Coanda ꢁow  
Hinged, removable ꢀlter access door  
Four eyebolts  
FINISH  
AIR FLOW  
FILTER ACCESS  
MOUNTING  
HARDWARE  
Six trim brackets  
SAFETY DEVICE  
Access door safety switch  
Disposable charcoal after-ꢀlter  
Remote ON/OFF switch  
ACCESSORIES  
(OPTIONS)  
Remote air discharge  
Air Purification Systems  
Download from Www.Somanuals.com. All Manuals Search And Download.  

TIMEX Weather Products Thermometer TX1002 User Manual
Toshiba Stereo System SD C67HT User Manual
Transcend Information Network Card TS RDP6 User Manual
True Fitness Treadmill CS10 User Manual
Univex Universal Remote TSU 2000 User Manual
Vantec Network Card NexStar DX User Manual
Vermont Casting Gas Grill VCS3507 User Manual
Vista Imaging Car Video System VFSM15 User Manual
Visual Land Graphics Tablet 10 User Manual
Waterford Precision Cycles Ventilation Hood Stainless Steel Box Hood User Manual