Traulsen Refrigerator RMC34 User Manual

Quality Refrigeration  
OWNER’S MANUAL  
Instructions for the installation, operation  
and maintenance of Traulsen:  
RMC Milk Cooler  
RMC34, RMC49 & RMC58 Models  
This Traulsen unit is built to our highest quality standards. We build our refrigerators and freezers this way as a matter of pride.  
This philosophy has made Traulsen the leader in commercial refrigeration since 1938. We thank you for your choice and con-  
fidence in Traulsen equipment and we know you will receive many years of utility from this equipment.  
All Traulsen units are placed on a permanent record file with the service department. In the event of any future questions you  
may have, please refer to the model and serial number found on the name tag affixed to the unit. Should you need service, call  
us on our toll free number, 800-825-8220 between 7:30 am - 4:30 pm CST, Monday thru Friday. You may also log onto www.  
traulsen.com for further information. It is our pleasure to help and assist you in every possible way.  
INSTALLER  
COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION  
INITIAL START DATE:  
MODEL TYPE:  
SERIAL NO.  
COMPANY/INDIVIDUAL NAME:  
INSTALLER:  
FORM NUMBER TR35944 (REV. 02-04-14)  
P/N 375-60324-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
II. RECEIPT INSPECTION  
III. INSTALLATION (continued)  
All Traulsen products are factory tested for performance  
and are free from defects when shipped. The utmost care  
has been taken in crating this product to protect against  
damage in transit.  
III. c - INSTALLING/ADJUSTING LEGS OR CASTERS:  
You should carefully inspect your unit for damage during  
delivery. If damage is detected, you should save all the  
crating materials and make note on the carrier’s Bill Of  
Lading describing the damage. A freight claim should be  
filed immediately. If damage is subsequently noted dur-  
ing or immediately after installation, contact our customer  
care team to file a freight claim. There is a fifteen (15)  
day limit to file freight damage with the carrier. Under no  
condition may a damaged unit be returned to Traulsen  
without first obtaining written permission (return autho-  
rization). You may contact Hobart/Traulsen customer  
care at 800-333-7447 to request a return or file a claim.  
III. d - CORD & PLUG:  
All self-contained models are shipped standard with a NEMA  
5-15P plug and 9 foot cord . Select only a dedicated electrical  
outlet for power source.  
NOTE: Do not under any circumstances, cut or remove the  
round grounding prong from the plug, or use an extension  
cord.  
III. INSTALLATION  
III. a - LOCATION:  
Select a proper location for your unit, away from extreme  
heat or cold.  
III. e - POWER SUPPLY:  
The supply voltage should be checked prior to connection to  
be certain that proper voltage for the cabinet wiring is available  
(refer to the serial tag to determine correct unit voltage, see page  
1). Make connections in accordance with local electrical codes.  
Use qualified electricians.  
III. b - PACKAGING:  
Your Traulsen unit is shipped from the factory bolted to a  
sturdy wooden pallet in stretch wrapped material.  
Most exterior stainless steel surfaces have a protective  
vinyl covering to prevent scratching during manufactur-  
ing, shipping and installation. After the unit is installed  
in place of application peel, remove and discard the  
covering from all surfaces.  
Use of a separate, dedicated circuit is required. Size wiring to  
handle indicated load and provide necessary over current protec-  
tor in circuit (see amperage requirements on the unit’s serial tag).  
IV. OPERATION  
To remove the wooden pallet, first if at all possible, we  
suggest that the cabinet remain bolted to the pallet dur-  
ing all transportation to the point of final installation. The  
bolts can then be removed with a 1/2” socket wrench.  
Avoid laying the unit on its back for removal of the pallet.  
IV. a - TEMPERATURE CONTROL:  
The temperature is set at the factory but local conditions may  
necessitate slight adjustment.  
NOTE: Traulsen does not recommend laying the unit  
on its back. If you must, please allow the unit to re-  
main in an upright position for 24 hours before plug-  
ging it in so that the compressor oils and refrigerant  
may settle.  
III. c - INSTALLING/ADJUSTING LEGS OR  
CASTERS:  
Casters are installed at the factory but will require adjust-  
ment upon installation.  
The temperature control is located behind the silver plug on the  
front side of the system area (dial thermometer side). To adjust,  
remove the plug turn the adjustment screw with a pair of pliers  
a small amount at a time; turning clockwise lowers the tempera-  
ture. An “OFF” position is fully counterclockwise and interrupts  
power to the compressor and condenser fan only, not the entire  
refrigerator.  
To adjust the legs or casters, loosen the two bolts and  
move leg or caster to desired location, spacing between  
leg or caster not to exceed 48 inches. Leg or caster on  
each end of the unit can not exceed 8 inches from the  
end of the cabinet.  
-2-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IV. OPERATION (continued)  
V. CARE & MAINTENANCE (continued)  
IV. a - TEMPERATURE CONTROL: (continued)  
V. b - REPLACING THE DOOR GASKETS:  
F
Colder  
R
O
Top Door  
Gasket  
N
Temperature  
Adjustment  
Shaft  
T
V. CARE & MAINTENANCE  
V. c - CLEANING THE CABINET SURFACES:  
WARNING: DISCONNECT ELECTRICAL POWER  
SUPPLY BEFORE CLEANING ANY PARTS OF THE  
UNIT.  
V. a - CLEANING THE CONDENSER/FILTER:  
The most important thing you can do to insure a long, reliable  
service life for your Traulsen is to regularly clean the condenser  
coil and or filter.  
Exterior stainless steel should be cleaned with warm wa-  
ter, mild soap and a soft cloth. Apply with a dampened  
cloth and wipe in the direction of the metal grain.  
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY  
BEFORE CLEANING ANY PARTS OF THE UNIT.  
Avoid the use of strong detergents and gritty, abrasive  
cleaners as they may tend to mar and scratch the sur-  
face. Do NOT use cleansers containing chlorine, such as  
bleach, this may promote corrosion of the stainless steel.  
To clean the condenser/filter, rst disconnect electrical power to  
the cabinet and remove the system side cover.  
Proceed to vacuum or brush any dirt, lint or dust from the finned  
condenser coil/filter, the compressor and other cooling system  
parts. If significant dirt is clogging the condenser fins or filter,  
use compressed air to blow this clear.To replace the system side  
cover reverse the process.  
Care should also be taken to avoid splashing the unit with  
water, containing chlorinated cleansers, when mopping  
the floor around the unit.  
For stubborn odor or spills, use baking soda and water  
(mixed to a 1 tbsp baking soda to 1 pint water ratio).  
V. b - REPLACING THE DOOR GASKETS:  
To remove the gasket to be replaced, grasp it firmly by one corner  
and pull it out. Before attempting to install a new gasket, both  
the unit and the gasket itself must be at room temperature. Insert  
the four corners first by using a rubber mallet (or hammer with  
a block of wood). After the corners are properly inserted, work  
your way towards the center from both ends by gently hitting  
with a mallet until the gasket is completely seated in place (see  
figure below for proper gasket placement).  
A stainless steel polish is recommended for shining of  
unit.  
NOTE: The gasket may appear too large, but if it is installed  
as indicated above it will slip into place.  
Front Door  
Gasket  
The unit is equipped with a drain for cleaning the inside  
of the unit.  
NOTE: System gasket attached with screw.  
-3-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VI. WIRING DIAGRAM  
NOTE: Refer to the wiring diagram below for any service work performed by a qualified technician.  
-4-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VII. TROUBLE SHOOTING GUIDE  
PROBLEM  
POSSIBLE SOLUTION  
1. Condensing unit fails to start.  
a. Check if cord & plug has been disconnected.  
b. Clean Condenser  
2. Condensing unit operates for prolonged  
periods or continuously.  
a. Are doors closed properly?  
b. Dirty condenser or filter. Clean properly.  
c. Evaporator coils iced. Needs to defrost.  
3. Food Compartment is too warm.  
a. Check door(s) and gasket(s) for proper seal.  
b. Check if a large quantity of warm food was recently added or the  
door was kept open for a long period of time.  
c. Clean Condenser  
(NOTE: Compressor may be cycling ON/OFF  
frequently)  
4. Food Compartment is too cold.  
5. Condensation on exterior surface.  
6. Compressor hums & does not start.  
a. Check if a large quantity of very cold or frozen food has recently  
been added. Allow adequate time for the cabinet to recover its nor-  
mal operating temperature.  
a. Check door(s) alignment and gaskets for proper seal.  
b. Condensation on the exterior surface of the unit is perfectly nor-  
mal during periods of high humidity.  
a. Call for service.  
VII. SERVICE ASSISTANCE  
VII. a - SERVICE CHECK LIST:  
Before calling for service, please check the following:  
Is the electrical cord plugged in?  
Is the fuse OK or circuit breaker on?  
Clean condenser coil  
Is the power switch on?  
If after checking the above items and the unit is still not operating properly, please contact an authorized Traulsen service  
agent. A complete list of authorized service agents was provided along with your Traulsen unit. If you cannot locate this,  
you may also obtain the name of a service agent from the Tech Service page at traulsen.com. If service is not satisfactory,  
please contact our in-house service department at:  
Traulsen  
4401 Blue Mound Road Fort Worth, TX 76106  
800.825.8220  
Traulsen reserves the right to change specifications or discontinue models without notice.  
VII. b - SERVICE INFORMATION:  
To purchase replacement parts or to speak to service support for Traulsen and most Hobart Refrigeration units please  
contact our Ft. Worth facility by phone at 800.825.8220 or fax to 817.740.6748 (parts) or 817.740.6757 (service).  
To obtain other service informaiton you may log onto:  
1. traulsen.com  
2. Select Service & Parts Tab (upper right of screen)  
3. Select one of the following: Service Finder, Service Parts Manuals, Parts Pricing & Warranty Registration  
NOTE: When calling for service support, please make sure you have model and serial number of unit available.  
-5-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IX. WARRANTIES  
STANDARD DOMESTIC WARRANTY  
TRAULSEN warrants new equipment to the original purchaser, when installed within the United States against  
defective material and workmanship for three (3) years from the date of original installation. Under this  
warranty, TRAULSEN will repair or replace, at its option, including service and labor, all parts found to be  
defective and subject to this warranty. Warranty term begins upon the date of Installation, the date of End User  
Invoice or the date of Dealer Invoice, whichever is proven to occur latest, not to exceed 18 months from Dealer  
Invoice date (the “Warranty Period”). Warranty excludes components that are removable without tools.  
The compressor part is warranted for an additional two (2) years. During this period TRAULSEN will supply  
replacement compressor(s) if deemed defective, however all installation, recharging and repair costs will remain  
the responsibility of the owner.  
This warranty does not apply to damage resulting from fire, water, burglary, accident, abuse, misuse, transit, acts  
of God, terrorism, attempted repairs, improper installation by unauthorized persons, and does not apply to food  
loss.  
For Traulsen units purchased with a remote feature, standard warranty will apply only to those components  
contained within the unit to the point of connection of the refrigeration lines leading to the remote condenser.  
“Defective Part Return” – All claimed defective replacement part(s) must be returned to TRAULSEN for  
inspection within 30 days from the date of the repair. Failure to return all claimed defective part(s) to  
TRAULSEN will invalidate the warranty claim, this warranty statement, and forfeit payment for those repairs  
affected.  
INTERNATIONAL COMMERCIAL WARRANTY  
TRAULSEN warrants to the original purchaser the Refrigeration Equipment shall be manufactured free from  
defects in material and workmanship under normal use and service for a period of one (1) year from date of  
shipment. Under this warranty, TRAULSEN will reimburse the purchaser for the replacement of any part of said  
equipment (excluding dryers & refrigerant gas) which then proves to be defective. This warranty does not  
apply to damage resulting from fire, water, burglary, accident, abuse, misuse, transit, acts of God, terrorism,  
attempted repairs, improper installation by unauthorized persons, and will not apply to food loss.  
TRAULSEN’S standard warranty does not apply to Export Sales. Rather, for a period of one (1) year from date  
of original installation not to exceed Fifteen (15) months from date of shipment from factory, TRAULSEN: will, at  
Traulsen’s sole discretion, replace or repair, F.O.B. factory, any defective parts normally subject to warranty and  
will not cover the cost of packing, freight or labor, such costs being the sole responsibility of the dealer.  
THERE ARE NO ORAL, STATUTORY OR IMPLIED WARRANTIES APPLICABLE TO TRAULSEN, INCLUDING BUT NOT  
LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WHICH  
EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. TRAULSEN SHALL HAVE NO OBLIGATION OR LIABILITY  
FOR CONSEQUENTIAL OR SPECIAL DAMAGES, INCLUDING, BUT NOT LIMITED TO, INDIRECT, PUNITIVE  
DAMAGES, LOSS OF USE, LOSS OF PRODUCT, DOWN TIME OR LOST PROFITS, GROWING OUT OF OR WITH  
RESPECT TO THE EQUIPMENT OR ITS SALE, OPERATION OR USE, AND TRAULSEN NEITHER ASSUMES NOR  
AUTHORIZES ANYONE ELSE TO ASSUME FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE  
EQUIPMENT OR ITS SALE, OPERATION OR USE OTHER THAN AS STATED HEREIN.  
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED AND CONSTITUTES  
TRAULSEN’S FULL OBLIGATION AND LIABILITY. WARRANTIES NOT AVAILABLE ON REMOTE MODELS.  
-6-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X. SERVICE PARTS LIST  
ITEM  
DESCRIPTION  
ALL MODELS  
PART NUMBER  
CASTER  
6" ADJUSTABLE CASTER NO LOCK  
6" ADJUSTABLE CASTER WITH LOCK  
4" ADJUSTABLE CASTER NO LOCK  
4" ADJUSTABLE CASTER WITH LOCK  
ALL MODELS  
SER-60538-00  
SER-60538-01  
SER-60536-00  
SER-60536-01  
LEG  
6" LEG  
SER-60542-00  
DOOR  
MODELS RMC34  
TOP DOOR ASSEMBLY  
FRONT DOOR ASSEMBLY  
MODELS RMC49  
200-60899-02  
200-60899-03  
TOP DOOR ASSEMBLY  
FRONT DOOR ASSEMBLY  
MODELS RMC58  
200-60899-00  
200-60899-01  
TOP DOOR ASSEMBLY  
FRONT DOOR ASSEMBLY  
GASKET TOP DOOR RMC34  
GASKET TOP DOOR RMC49  
GASKET TOP DOOR RMC58  
GASKET FRONT DOOR RMC34  
GASKET FRONT DOOR RMC49  
GASKET FRONT DOOR RMC58  
GASKET SYSTEM RMC34  
GASKET SYSTEM RMC49  
GASKET SYSTEM RMC58  
DOOR CATCH  
200-60899-04  
200-60899-05  
341-60267-00  
341-60267-01  
341-60267-02  
341-60262-00  
341-60262-01  
341-60262-02  
341-60268-00  
341-60268-01  
341-60268-02  
3801100  
BUMPER  
358-60247-00  
560-10280-00  
560-10280-01  
SER-60620-00  
409-130-056-200  
DOOR SLIDE LH  
DOOR SLIDE RH  
PIN FRONT DOOR  
HINGE  
FLOOR RACKS ALL MODELS  
FLOOR RACK 14-3/4"  
701-61633-00  
701-61634-00  
600-70050-00  
600-70050-01  
358-10077-00  
MODELS RMC58  
FLOOR RACK 8-3/4"  
MODELS RMC34  
AIR DUCT ASSEMBLY  
MODELS RMC49 & RMC58  
AIR DUCT ASSEMBLY  
ALL MODELS  
AIR DUCT  
DRAIN  
STOPPER 1"  
-7-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
X. SERVICE PARTS LIST (continued)  
ITEM  
DESCRIPTION  
PART NUMBER  
REF SYSTEM  
MODELS RMC34S  
REPLACEMENT REFRIGERATION SYSTEM SINGLE ACCESS  
MODELS RMC34D  
SER-60617-00  
SER-60617-01  
SER-60618-00  
SER-60618-01  
SER-60619-00  
SER-60619-01  
REPLACEMENT REFRIGERATION SYSTEM DUAL ACCESS  
MODELS RMC49S  
REPLACEMENT REFRIGERATION SYSTEM SINGLE ACCESS  
MODELS RMC49D  
REPLACEMENT REFRIGERATION SYSTEM DUAL ACCESS  
MODELS RMC58S  
REPLACEMENT REFRIGERATION SYSTEM SINGLE ACCESS  
MODELS RMC58D  
REPLACEMENT REFRIGERATION SYSTEM DUAL ACCESS  
ALL MODELS  
CONTROL  
MICROPROCESSOR CONTROL  
337-60445-00  
337-60447-00  
337-60448-00  
344-60249-00  
MICROPROCESSOR COIL TEMPERATURE SENSOR  
MICROPROCESSOR CABINET TEMPERATURE SENSOR  
THERMOMETER DIAL  
NOTE: Part numbers listed are for standard products as currently manufactured. For products manufactured as  
other than standard, please contact the factory.  
-8-  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOURS OF OPERATION:  
Monday thru Friday 7:30 am - 4:30 pm CST  
Traulsen  
4401 Blue Mound Road Fort Worth, TX 76106  
Phone 800.825.8220 Fax 817.740.6757  
traulsen.com  
Quality Refrigeration  
© 2014 Traulsen - All Rights Reserved  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Taurus Group Slow Cooker Egypt 600 User Manual
TOA Electronics TV Receiver WT 4820 User Manual
Toshiba All in One Printer GA 1191 User Manual
Toshiba Network Card PROSEC T3H User Manual
Toshiba Projection Television 46HM95 User Manual
U Line Freezer U 3045RDCOL 00 User Manual
Uniden Cordless Telephone DWX207 User Manual
Uniden Telephone CEZ200 User Manual
VTech Cordless Telephone DS6401 User Manual
VTech CRT Television VT181CH User Manual