Transition Networks Network Router M GE PSW LX 01 User Manual

User’s Guide  
M/GE-PSW-SX-01, M/GE-PSW-LX-01  
Stand-Alone Media Converters  
• Copper to Fiber  
• 10/100/1000Base-T to 1000Base-X  
The miniature plug-and-play M/GE-PSW-xX-01, 2-  
port Ethernet/Fast Ethernet bridging media  
converters allow integrating fiber optic cable to  
10/100/1000 Unshielded Twisted Pair (UTP) environments while providing a space-  
saving alternative to traditional sized media converters.  
M/GE-PSW-xX-01: Auto-Negotiation, AutoCross, Far End Fault (FEF)  
Part Number  
Copper - Port  
Fiber-Optic -Port  
10/100/1000Base-T  
1000Base-FX  
M/GE-PSW-SX-01 (SC) RJ-45  
100 m (328 ft)*  
M/GE-PSW-LX-01 (SC) RJ-45  
100 m (328 ft)*  
SX, 850 nm, multimode 62.5/125  
200m (722 ft), 50/125 550m (1,805 ft)  
LX, 1310 nm single mode  
10 km (2.1 miles)*  
*Typical maximum cable distance; actual distance is dependent upon the physical  
characteristics of the network.  
Installation . . . . . . . . . . . . . . . . . .2  
Operation . . . . . . . . . . . . . . . . . . .6  
Cable Specifications . . . . . . . . . .10  
Technical Specifications . . . . . . .11  
Troubleshooting . . . . . . . . . . . . .12  
Contact Us . . . . . . . . . . . . . . . . .13  
Declaration of Conformity . . . . .14  
Compliance Information . . . . . . .15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
M/GE-PSW-xX-01  
Installation -- Continued  
Installation -- Continued  
Connect the twisted-pair copper cable  
Powering the media converter  
The AutoCross feature allows either MDI (straight-through) or MDI-X (crossover)  
cable connections to be configured automatically, according to network conditions.  
The M/GE-PSW-xX-01 media converter is powered by using a DC power adapter  
through the barrel connector on its rear panel, as shown below.  
1. Locate or build IEEE 803.2™ compliant 10/100/1000Base-T cables with RJ-  
45 connectors installed at both ends.  
M/GE-PSW-xX-01 Back Panel Power  
Back Panel  
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the  
M/GE-PSW-xX-01 media converter.  
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on  
Barrel Connector  
5-28 VDC  
the other device (switch, workstation, etc.).  
Power adapter  
RJ-45 port  
on the media  
converter  
RJ-45 port  
on the other device  
(switch, work station, etc.)  
AC power  
1. Connect the barrel connector of the power adapter to the media converter’s  
power port (located on the back panel of the media converter).  
2. Connect the power adapter plug to AC power.  
Note: With AutoCross permanently enabled, the link LED only lights when a valid  
end-to-end connection is made.  
3. Verify that the media converter is powered up by observing the illuminated  
LED power indicator light on the front panel.  
DC power  
Consult the user’s guide for the Transition Networks SPS-1872-SA DC external  
power supply for powering the media converter.  
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
5
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
M/GE-PSW-xX-01  
Operation  
Operation -- Continued  
Status LEDs  
Product features  
Use the LEDs to monitor the status of the media converter.  
Congestion reduction  
The M/GE-PSW-xX-01 media converters do not forward collision signals or error  
packets from one collision domain to another, resulting in improvements in  
baseline network performance. In addition, the media converter filters packets  
destined for local devices, which reduces network congestion also.  
Front Panel  
TP-Link/Act LED  
Fiber-Link/Act LED  
Auto-Negotiation  
The Auto-Negotiation feature is ON permanently for the M/GE-PSW-xX-01 media  
converters. Auto-Negotiation allows the media converter to configure itself  
automatically to achieve the best possible mode of operation over a link. It  
broadcasts speed (10 /100/1000 Mb/s) and duplex capabilities (full or half) to the  
other device and negotiates the best mode of operation. Auto-Negotiation allows  
quick and easy installation because the optimal link is established automatically.  
Power ON LED  
LED states are as follows:  
In a scenario where an auto-negotiation device is linked to a non-negotiating device,  
the negotiating device via parallel detection recognizes the speed of that second  
device then establishes the best operating speed (10/100/100Mbs) at half-duplex.  
Fiber-Link/Act LED  
Green  
ON  
= Link (fiber)  
AutoCross™  
Flashing = Activity  
The AutoCross feature allows using either straight-through (MDI) or crossover  
(MDI-X) copper cables when connecting to 10Base-T or 100Base-TX devices.  
AutoCross determines the characteristics of the connection and automatically  
configures the device to link up, regardless of the copper cable configuration, MDI  
or MDI-X.  
TP-Link/Act LED  
Green  
ON  
= Link (copper)  
Flashing = Activity  
Power LED  
Green  
Link Pass-Through  
ON  
= Connected to power  
The Link Pass-Through feature (illustrated below) allows the media converter to  
monitor both the fiber and copper RX (receive) ports for loss of signal. In the event  
of an RX signal loss (1), the media converter will automatically disable the TX  
(transmit) signal (2), thus “passing through” the link loss (3). The far-end device is  
automatically notified of the link loss (4), which prevents the loss of valuable data  
unknowingly transmitted over an invalid link.  
media converter A  
disables the fiber TX link  
media converter B  
loses the fiber RX link  
2
3
Near-End  
Device  
Media  
Converter A  
Media  
Converter B  
Far-End  
Device  
4
1
original fault  
on the copper link  
media converter B  
disables the copper link  
Note: Both copper and fiber cables must be installed before the LEDs will light.  
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
7
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
M/GE-PSW-xX-01  
Operation -- Continued  
Operation -- Continued  
Product features -- continued  
Product features -- continued  
Automatic link restoration  
Distance extension  
The media converter will automatically re-establish the link when connected to  
switches if the link is lost, even with Auto-Negotiation and Link Pass-through (both  
directions) enabled.  
The M/GE-PSW-xX-01 media converters can segment one (1) 10Base-T copper  
Ethernet, 100Base-T copper fast Ethernet, or 1000Base-T copper Gigabit Ethernet,  
and one (1)1000 Base-X fiber Fast Ethernet collision domain:  
In a half-duplex Ethernet or Fast Ethernet environment, the M/GE-PSW-xX-01  
media converters extend network distances by segmenting collision domains so that  
the 512-Bit Rule applies separately to each collision domain.  
Full-Duplex flow control  
In a full-duplex network, maximum cable lengths are determined by the type of  
cables used—see page 1 (front cover) for M/GE-PSW-xX-01 cable specifications.  
In a full-duplex Ethernet or Fast Ethernet environment, the M/GE-PSW-xX-01  
media converters extend network distances to the physical cable limitations  
imposed by the selected twisted-pair copper fiber cables.  
The 512-Bit Rule does not apply in a full-duplex network.  
Note: Full duplex is ON permanently for the fiber port only.  
Rate conversion  
The M/GE-PSW-xX-01 media converters allow the following connections:  
Half-Duplex flow control (512-Bit Rule)  
In a half-duplex network, the maximum cable lengths are determined by the round-  
trip delay limitations of each Fast Ethernet collision domain. (A collision domain is  
the longest path between any two terminal devices; e.g., a terminal, switch, or  
router.)  
10Mb/s devices on a 10Base-T legacy copper network to 1000Mb/s devices on  
a 1000Base SX/LX Gigabit Ethernet fiber network.  
100Mb/s devices on a 100Base-T legacy copper network to 1000Mb/s devices  
on a 1000Base SX/LX Gigabit Ethernet fiber network.  
The 512-Bit Rule determines the maximum length of cable permitted by calculating  
the round-trip delay in bit-times (BT) of a particular collision domain. If the result  
is less than or equal to 512 BT, the path is good.  
For more information on the 512-Bit Rule, see the white paper titled “Collision  
Domains” on the Transition Networks website at: www.transition.com  
Back pressure  
Back pressure is used in half duplex mode. It ensures the retransmission of  
incoming packets when a port using half-duplex is temporarily unable to receive  
incoming frames.  
Flow Control  
The process of adjusting the flow of data from one device to another ensures that  
the receiving device can handle all the incoming data. This is particularly important  
where the sending device is capable of transmitting data much faster than the  
receiving device can accept it.  
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
9
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
M/GE-PSW-xX-01  
Cable Specifications  
The physical characteristics must meet or exceed IEEE 802.3™ specifications.  
Technical Specifications  
For use with Transition Networks Model M/GE-PSW-xX-01 converters.  
Standards:  
Data rate:  
Dimensions:  
Weight:  
IEEE 802.3-2000  
Fiber cable  
10 Mb/s, 100 Mb/s, 1000 Mb/s  
1.8"W x 3.35"D x 0.85"H (45.7 x 85.1 x 21.6 mm)  
3.15 oz. (127.5 g) approximately  
Bit Error Rate:  
<10-9  
9 μm  
single mode fiber (recommended):  
Multimode fiber (recommended):  
Multimode fiber (optional):  
62.5/125 μm  
100/140, 85/140, 50/125 μm  
MTBF*:  
24,466 hours (MIL217F2 V5.0) (MIL-HDBD-217F)  
100,130 hours (Bellcore7 V5.0)  
M/GE-PSW-SX-01 (SC)  
Fiber Optic Transmitter Power:  
Fiber Optic Receiver Sensitivity:  
Link Budget:  
850nm multimode  
min: -10.0 dBm  
min: -17.0 dBm  
7.0 dB  
max: -4.0 dBm  
max: -0.0 dBm  
Packet size:  
MAC addresses:  
Maximum packet size:  
Memory: 9256K bytes  
8K  
1632 bytes, untagged  
1628 bytes, tagged  
M/GE-PSW-LX-01 (SC)  
Fiber-optic Transmitter Power:  
Fiber-optic Receiver Sensitivity:  
Link Budget:  
1310 nm single mode  
min: -9.5 dBm  
min: -20.0 dBm  
10.5 dB  
max: -3.0 dBm  
max: -3.0 dBm  
Power sources:  
Unit will accept - 5 to 28 VDC  
Barrel connector - Wall Mount AC Adapter  
(400mA at 12VDC)(The external power supply provided  
with this product is UL listed by the power supply’s  
manufacturer.)  
The fiber optic transmitters on this device meet Class I Laser safety requirements per  
IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.  
Power consumption:  
Environment:  
262mA @ 12VDC, 3.15 watts  
Copper cable  
Tmra**:  
0°C to 50°C (32°F to 122°F )  
-25°C to 65°C (-13°F to 149°F)  
5% to 95%, non-condensing  
0 to 10,000 feet  
Category 5 and Category 5e: minimum requirement  
Storage Temp:  
Humidity:  
Altitude:  
Gauge  
24 to 22 AWG  
Attenuation  
Maximum Cable Distance  
22.0 dB /100m @ 100 MHz  
100 meters  
Warranty:  
Lifetime  
• Straight-through or crossover twisted-pair cable may be used.  
• Shielded (STP) or unshielded (UTP) twisted-pair cable may be used.  
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network.  
• All four pairs are used in a gigabit Ethernet network.  
• Use only dedicated wire pairs for the active pins:  
*MTBF is estimated using the predictability method. This method is based on MIL-  
217F at 25°C ambient temperature, typical enclosure heat rise of 10°C with nominal  
operating conditions and parameters. Installation and configuration specific MTBF  
estimates are available upon request. Contact Technical Support.  
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)  
• Do not use flat or silver satin wire.  
**Manufacturer’s rated ambient temperature.  
CAUTION: Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232,  
RS422, RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra-  
building (inside plant) link segments that are not subject to lightening transients or  
power faults. Copper-based media ports, e.g., Twisted Pair (TP) Ethernet, USB,  
RS232, RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter-  
building (outside plant) link segments that are subject to lightening transients or power  
faults. Failure to observe this caution could result in damage to equipment.  
S traight Through Cable  
Crossover Cable  
1
2
1
2
1
2
1
2
Twisted Pair #1  
Twisted Pair #1  
3
6
3
6
3
6
3
6
Twisted Pair #2  
Twisted Pair #2  
CAT5e Gigbit Ethernet  
Straight-Through Cable  
1
2
1
2
Twisted Pair #1  
Twisted Pair #2  
Twisted Pair #3  
Twisted Pair #4  
3
4
3
4
5
6
5
6
7
8
7
8
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
11  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
M/GE-PSW-xX-01  
Technical Specifications -- Continued  
Contact Us  
Copper-based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232, RS422,  
RS485, DS1, DS3, Video Coax, etc., are intended to be connected to intra-building  
(inside plant) link segments that are not subject to lightening transients or power  
faults. Copper based media ports, e.g., Twisted Pair (TP) Ethernet, USB, RS232,  
RS422, RS485, DS1, DS3, Video Coax, etc., are NOT to be connected to inter-  
building (outside plant) link segments that are subject to lightening transients or power  
faults.  
Technical Support  
Technical support is available 24 hours a day.  
US and Canada:  
International:  
1-800-260-1312  
00-1-952-941-7600  
Transition Now  
Chat live via the Web with Transition Networks Technical Support.  
Log onto www.transition.com and click the Transition Now link.  
The product is certified by the manufacturer to comply with DHHS Rule 21/CFR,  
Subchapter J applicable at the date of manufacture.  
Web-Based Seminars  
Transition Networks provides seminars via live web-based training.  
WARNING: Visible and invisible laser radiation when open. Do not stare into the  
beam or view directly with optical instruments. Failure to observe this warning could  
result in an eye injury or blindness.  
WARNING: Use of controls, adjustments, or the performance of procedures other  
than those specified herein could result in hazardous radiation exposure.  
E-Mail  
Ask a question anytime by sending an e-mail to our technical support staff.  
The information in this user’s guide is subject to change. For the most up-to-date  
information, view the user’s guide on-line at: www.transition.com.  
Address  
Transition Networks  
10900 Red Circle Drive  
Minnetonka MN 55343, U.S.A.  
Troubleshooting  
If the media converter fails, isolate and correct the failure by determining the answers  
to the following questions and then taking the indicated action:  
telephone:  
toll free:  
fax:  
952-941-7600  
800-526-9267  
952-941-2322  
1.  
Is the power LED illuminated and did the TX and FX LEDs turn ON then turn  
OFF?  
NO  
Is the power adapter the proper type of voltage and cycle frequency for  
the AC outlet?  
Is the power adapter properly installed in the media converter and in the  
outlet?  
Contact Technical Support: US/Canada: 1-800-260-1312, International:  
00-1-952-941-7600.  
YES  
Proceed to step 2.  
Note the following:  
As a link pass-through device both copper and fiber cables must be  
installed before the LEDs will light.  
2.  
Are the “TX and FX-Link/ACT” LEDs illuminated on the RJ-45 port ?  
NO  
Check the copper cables for proper connection.  
Check the fiber cables for proper connection.  
Contact Technical Support: US/Canada: 1-800-260-1312, International:  
00-1-952-941-7600.  
YES  
Contact Technical Support: US/Canada: 1-800-260-1312, International:  
00-1-952-941-7600.  
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
13  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
M/GE-PSW-xX-01  
Declaration of Conformity  
Compliance Information  
CE Mark  
Declaration of Conformity  
FCC Regulations  
This equipment has been tested and found to comply with the limits for a class A digital device,  
pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection  
against harmful interference when the equipment is operated in a commercial environment. This  
equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in  
accordance with the instruction manual, may cause harmful interference to radio communications.  
Operation of this equipment in a residential area is likely to cause harmful interference, in which  
case the user will be required to correct the interference at the user's own expense.  
Canadian Regulations  
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out  
on the radio interference regulations of the Canadian Department of Communications.  
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables  
aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage  
radioélectrique édicté par le ministère des Communications du Canada.  
Name of Mfg:  
Model:  
Transition Networks  
10900 Red Circle Drive, MinnetonkaMN 55343 U.S.A.  
M/GE-PSW-xX-01 Series Media Converters  
Part Number(s):  
Regulation:  
M/GE-PSW-LX-01 and M/GE-PSW-SX-01  
EMC Directive 89/336/EEC  
Purpose: To declare that the M/GE-PSW-xX-01 to which this declaration refers is in  
conformity with the following standards.  
EN 55022:1994 + A1:1995 + A2:1997; EN 55024:1998 + A1:2001 + A2:2003  
I, the undersigned, hereby declare that the equipment specified above conforms to the  
above Directive(s) and Standard(s).  
European Regulations  
Warning This is a Class A product. In a domestic environment this product may cause radio  
interference in which case the user may be required to take adequate measures.  
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei  
Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für  
Gegenmaßnahmen verantwortlich.  
January, 2008_____  
Stephen Anderson, Vice President of Engineering  
Date  
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque  
de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures  
spécifiques appropriées.  
In accordance with European Union Directive 2002/96/EC of the European  
Parliament and of the Council of 27 January 2003, Transition Networks will  
accept post usage returns of this product for proper disposal. The contact  
information for this activity can be found in the 'Contact Us' portion of this  
document.  
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE  
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result  
in damage to the public telephone network.  
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-  
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der  
Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über  
Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer  
Konformität.  
Tech Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)  
[email protected] -- Click the “Transition Now” link for a live Web chat.  
15  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
M/GE-PSW-xX-01  
Trademark Notice  
All trademarks and registered trademarks are the property of their respective owners.  
Copyright Restrictions  
© 2001-2005 Transition Networks.  
All rights reserved. No part of this work may be reproduced or used in any form or by any  
means—graphic, electronic, or mechanical—without written permission from Transition  
Networks.  
Printed in the U.S.A.  
33398.A  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Targus Mouse Wireless Laser Rechargable Notebook Mouse User Manual
Toshiba Cell Phone Integrated Wireless Handset User Manual
Toshiba Personal Computer A10 Series User Manual
Toshiba Projector TLP T70M User Manual
Transition Networks Switch SBFTF10XX 10X User Manual
Underwater Kinetics Work Light SL4 eLED User Manual
Uniden Flat Panel Television BTS150 User Manual
United States Stove Fan EC95 User Manual
Verbatim Computer Drive Mini DVDR DL Media User Manual
Weber Charcoal Grill SMOKEY JOE GOLD User Manual