SMACF10xx Management Aggregation Converter
Manufacturing
& Logistics
QUICK START GUIDE
Sales & Marketing
Install SMACF10xx in Network
1.
Unpack and Install SMACF10xx Units Place SMACF10xx units
on table or other flat, stable surface in well-ventilated area.
MM or SM Fiber
2.
Power On SMACF10xx Units Install power adapter cord at back
of each SMACF10xx unit. Connect power adapter plug to AC
power. Verify power by observing illuminated LEDs.
PointSystem
Modular Chassis
SNMP Management
of all Remote Reporting Units
™
3.
Connect SMACF10xx Units to Ethernet Network Locate path
™
to Ethernet segment. Use Category 5 twisted-pair cable and
appropriate fiber cable to connect SMACF10xx Management Unit
through any port (optionally through a hub or switch) to the
Ethernet segment. Connect AT LEAST ONE port on EACH
installed SMACF10xx Reporting Unit (optionally through a hub or
switch) to the same Ethernet™ segment.
Copper Switch
Network managed by CPSMM-xxx PointSystem™ Management
Module connected to switch on same segment as Reporting Units.
™
Configure Main Management Unit or Management Module
Installed in Chassis
Main Management Unit
Reporting Unit
NOTE: The SMAC10xx Management Unit contains both a Management
Unit and a Reporting Unit. Each must be configured separately.
4.
Connect Management Unit or Management Module to Terminal
Locate null modem DB-9 serial port cable with female DB-9
connector. Attach DB-9 serial port female cable connector to
DB-9 serial port male connector on SMACF10xx Management
Unit OR on CPSMM-xxx PointSystem™ Management Module
installed in Media Conversion Center. Attach other end of DB-9
serial port cable to ASCII terminal or terminal emulator.
CAT 5
MM or SM Fiber
In-Band Management
VLAN Segmentation
CAT 5
CAT 5
LAN Switch
10 or 100 Mb/s Speed Selection
CAT 5
5.
6.
Verify Terminal Settings Default terminal settings are 9600
Baud/ 8 data bits/ 1 stop bit/ no parity. If necessary, use methods
appropriate to terminal to modify settings.
SNMP Management
of Both Main Management
and Reporting Units
Bring up Management Unit Interface at Terminal (SMACF10xx
Management Unit ONLY) First set switch at back of SMACF10xx
Management Unit to UP position. (SMACF10xx Management
Unit and CPSMM-xxx PointSystem™ Management Module) Press
<enter> at terminal keyboard to bring up command-line prompt.
Network managed by SMACF10xx Management Unit.
7.
Enter superuser Mode At command-line prompt, type and enter
the su command, using the case-sensitive Transition Networks
default password private.
CPSMM100> SU=private