Features and  
Benefits  
AIR HANDLING UNITS  
Features  
New Features  
Improved filter access and latch -  
Eliminate current T-bar and shipping  
bracket.  
Provision for 1 1/8” thick field supplied  
electrostatic filter  
Ships horizontal  
Six way convertibility- horizontal (left  
and right), upflow, downflow (front and  
rear access)  
Electrical, refrigerant, condensate and  
blower access convertible to either side  
Reversible Duct Flanges - Fits up to  
1 1/2” duct board  
Corrosion resistant galvanized steel with  
attractive finish  
Improve controls access with control  
box mounted next to blower.  
Internally enhanced finned coil tubes  
Direct drive motor  
40 VA transformer with 5 amp  
automotive style fuse on 3 tons and less  
TWE  
Standard filters  
5 Amp automotive style fuse replaces  
Bussman “red cap” fuse on 3.5 to 5 ton  
models  
Multi-speed blower  
220 volt primary and 24 volt secondary  
transformer  
Blower mounting brackets improved -  
Front access to screw with power driver  
Insulated cabinet  
Improved bottom carton cushioning  
External access to heater circuit breakers  
Start kits are not required  
1” thick foil faced insulation for all  
models  
Built-in indoor fan delay function for  
increased efficiency. No kit required.  
TTA  
TTB  
CONDENSING UNITS  
Features:  
Benefits:  
Vertical Air Discharge  
High Efficiency TRANE Climatuff®  
Compressor  
Flexibility in application  
Quality and reliability  
Uniform covering for a smooth,  
attractive and corrosion-resistant finish  
Powder Paint finish  
Brazed or flare connections  
TWE5-PRC000-EN  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
System  
Performance  
95º F Indoor  
Outdoor Unit  
Indoor Unit  
*MBh  
kW  
CFM  
CMH  
Ducted Air Handlers  
TTB524CA00A  
TTB530CA00A  
TTB530CA00A  
TTB536CA00A  
TTA030CD00A†  
TTA030CD00A†  
TTA040CD00A†  
TTA040CD00A†  
TTA050CD00A†  
TTA060CD00A†  
TWE030CA40B  
TWE030CA40C  
TWE040CA40C  
TWE040CA40C  
TWE030CA40B  
TWE040CA40C  
TWE040CA40C  
TWE050CA50D  
TWE050CA50D  
TWE050CA50D  
25.8  
30.8  
32.4  
39.0  
30.5  
32.5  
41.0  
43.9  
52.7  
62.8  
6.9  
8.4  
9.5  
10.1  
8.9  
9.4  
12.0  
12.8  
15.4  
18.4  
900  
1000  
1200  
1200  
1000  
1125  
1325  
1600  
1800  
1800  
1520  
1689  
2038  
2038  
1689  
1900  
2238  
2703  
3040  
3040  
†Outdoor: 380-415/50/3, Indoor: 220-240/50/1  
*Cooling capacity is based on 94ºF outside ambient, 80ºF DB/67ºF WB air on coil.  
4
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model  
Nomenclature  
TW  
E
0
30  
C
A
4
0
A
0
1,2  
3
4
5,6  
7
8
9
10  
11  
12  
Digit 7  
Digit 1,2 - Product Type  
TW = Split System Component  
Heat Pump Compatible  
C = Development Sequence  
Digit 8 - Voltage  
A = 220/1/50  
Digit 3 - Airflow Configuration  
E = Convertible  
Digit 9 - Refrigerant Flow Control  
4 = Accutron Flow Control/  
Check Valve  
Digit 4 - Refrigerant Connections  
0 = Brazed  
5 = Flare  
5 = Bleed TXV  
Digit 10 - Not Used  
Digits 5,6 - Nominal Capacity  
30 = 30 MBh  
Digit 11 - Minor Design Change  
40 = 40 MBh  
50 = 50 MBh  
Digit 12 - Service Digit  
TWE5-PRC000-EN  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product  
Data  
Table 1 — TWE Product Specifications  
Model  
TWE030CA40B  
TWE040CA40C  
TWE050CA50D  
Power Conn.— Volts/Ph/Hz  
Indoor Coil - Type  
Rows  
220/1/50  
Plate Fin  
3
220/1/50  
Plate Fin  
3
220/1/50  
Plate Fin  
3
Fins per inch (Fins per 25.4mm)  
Face Area ft2-(m2)  
Tube Size in. (mm)  
Refrigerant Control  
Drain Conn. Size in. (mm)  
Duct Connections  
Indoor Fan - Type  
No. Used  
14  
14  
14  
3.21 (.30)  
5.04 (.47)  
6.19 (.58)  
3
3
3
/
8
(9.52)  
/
8
(9.52)  
/
8
(9.52)  
FCCV  
4
FCCV  
4
FCCV  
4
3
3
3
/
NPT  
/
NPT  
/
NPT  
—————————— SEE OUTLINE DRAWING ———————————  
Centrifugal  
1
Centrifugal  
1
Centrifugal  
1
Diameter in. (mm)  
Width in. (mm)  
Type Drive - No. Speeds  
Airflow (High)  
10.0 (254.0)  
8.0 (203.2)  
Direct - 3  
10.0 (254.0)  
10.0 (254.0)  
Direct - 3  
11.0 (279.4)  
10.0 (254.0)  
Direct - 3  
CFM @ 0.0 in. w.g.  
CMH @ 0.0 mm w.g.  
No. Motors - HP  
Motor RPM  
—————————— SEE FAN PERFORMANCE TABLE ——————————  
—————————— SEE FAN PERFORMANCE TABLE ——————————  
1 - 1/3  
1000  
220/1/50  
2.6  
1 - 1/3  
900  
1 - 3/4  
900  
220/1/50  
4.5  
10.1  
Volts/Ph/Hz  
220/1/50  
2.1  
F.L. Amps  
L.R. Amps  
3.3  
4.2  
Filters  
Vertical Applications  
Filter Furnished  
Type Furnished  
No.-Size-Thickness  
Horizontal Applications  
Filter Furnished  
Type Recommended  
No.-Size-Thickness  
Refrigerant Line Size  
Line Size ID Gas in. (mm)  
Line Size ID Liquid in. (mm)  
Dimensions (H x W x D)  
Crated - in.  
Yes  
Throwaway  
1 - 20 x 20 - 1  
Yes  
Throwaway  
1 - 20 x 20 - 1  
Yes  
High Velocity  
1 - 2 2 x 20 - 1  
No  
No  
No  
—————————— SEE NOTE BELOW ——————————  
—————————— SEE NOTE BELOW ——————————  
7
/
8
(22.23)  
(9.52)  
11/8 (28.56)  
11/8 (28.56)  
3
3
3
/8  
/8  
(9.52)  
/8  
(9.52)  
44.5 x 24.0 x 23.5  
(1130 x 610 x 597)  
43.0 x 21.5 x 21.0  
(1092 x 546 x 533)  
53.25 x 26.0 x 23.5  
(1353 x 660 x 597)  
52.0 x 23.5 x 21.0  
(1321 x 597x 533)  
59.5 x 26.0 x 23.5  
(1511 x 660 x 597)  
58.0 x 23.5 x 21.0  
(1473 x 597 x 533)  
- (mm)  
Uncrated - in.  
- (mm)  
Weight Ibs. (kg)  
Shipping  
125 (56.7)  
115 (52.2)  
165 (74.8)  
150 (68.0)  
198 (898)  
183 (83.0)  
Net  
Minimum filter size for horizontal applications based on airflow selection and calculated as follows:  
Low Velocity Filter: Face Area (ft2) = CFM/300  
High Velocity Filter: Face Area (ft2) = CFM/500  
6
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product  
Data  
Table 2 — TTB5 Product Specifications1,2  
Model  
TTB524CA00A  
TTB530CA00A  
Power Conn. — Volts/Ph/Hz  
Min. Brch. Cir. Ampacity3  
Br. Cir. Max. (Amps)  
Prot. Rtg. Recmd. (Amps)  
Compressor Type  
No. Used - No. Speeds  
Volts/Ph/Hz  
200-230/1/50  
200-230/1/50  
19  
20  
30  
30  
30  
30  
Climatuff® Reciprocating  
1 — 1  
Climatuff® Reciprocating  
1 — 1  
200-230/1/50  
13.9 — 60  
180-253  
200-230/1/50  
13.9 — 79  
180-253  
R.L. Amps - L.R. Amps  
Voltage Utilization Range  
Brch. Cir. Selec. Cur. Amps  
Outdoor Fan - Type  
Dia. - in. (mm) - No. Used  
Type Drive - No. Speeds  
CFM @ 0.0 in. w.g.4  
CMH @ 0.0 mm w.g.  
No. Motors  
13.9  
14.9  
Propeller  
18 (457) — 1  
Direct — 1  
1925  
Propeller  
18 (457) — 1  
Direct — 1  
2225  
908  
1050  
1
(124)  
1
(124)  
1
1
Motor HP (W)  
/6  
/6  
Motor Speed RPM  
Volts/Ph/Hz  
1100  
200-230/1/50  
1.30  
1100  
200-230/1/50  
1.30  
F.L. Amps  
Outdoor Coil - Type  
Rows - Fins/in. (Fins/mm)  
Face Area - ft2 (m2)  
Tube Size - in. (mm)  
Refrigerant  
Spine Fin™  
1 — 24 (1)  
Spine Fin™  
1 — 24 (1)  
10.96 (1.02)  
14.93 (1.39)  
3
3
/8  
(10)  
/8  
(10)  
R-225 - lbs. (kg)  
4 lbs, 15 oz. (2.24)  
6 lbs, 11 oz. (3.03)  
Factory Supplied  
Line Size - O.D. Gas6 - in. (mm)  
Line Size - O.D. Liq.6 - in. (mm)  
Dimensions (H x W x D)  
Crated - in.  
Yes  
Yes  
3
3
/
4
(20)  
/
4
(20)  
5/16 (8)  
5/16 (8)  
263/8 x 267/8 x 267/8  
(670 x 683 x 683)  
See Outline Dwg.  
333/8 x 267/8 x 267/8  
(848 x 683 x 683)  
See Outline Dwg.  
- (mm)  
Uncrated  
Weight lbs. (kg)  
Shipping  
176 (79.8)  
166 (75.3)  
184 (83.5)  
174 (78.9)  
Net  
Notes:  
1Rated in accordance with ARI Standard 210/240.  
2Rated in accordance with ARI Standard 270.  
3Calculated in accordance with National Electric Code. Suitable for use with HACR circuit breakers or fuses.  
4Standard air — dry coil — outdoor.  
5This value approximate. For more precise value see unit nameplate and service instructions.  
6Max. linear length 80 ft.; max. lift — suction 60 ft.; max. lift — liquid 60 ft. Max. length of precharged tubing 50 ft. For greater length refer to  
Refrigerant Piping Manual Pub. No. 32-3009.  
TWE5-PRC000-EN  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product  
Data  
Table 3 — TTB5 Product Specifications1,2  
Model  
Power Conn. - Volts/Ph/Hz  
Min. Brch. Cir. Ampacity3  
Br. Cir. Max. (Amps)  
TTB536CA00A  
200-230/1/50  
24  
40  
40  
Prot. Rtg. Recmd. (Amps)  
Compressor Type  
No. Used - No. Speeds  
Volts/Ph/Hz  
Climatuff® Reciprocating  
1 — 1  
200-230/1/50  
17.6 — 95  
180-253  
R.L. Amps - L.R. Amps  
Voltage Utilization Range  
Brch. Cir. Selec. Cur. Amps  
Outdoor Fan - Type  
Dia. in. (mm) - No. Used  
Type Drive - No. Speeds  
CFM @ 0.0 in. w.g.4  
CMH @ 0.0 mm w.g.  
No. Motors  
17.6  
Propeller  
18 (457) — 1  
Direct — 1  
2225  
1050  
1
(124)  
1
Motors HP (W)  
/6  
Motor Speed RPM  
Volts/Ph/Hz  
1100  
200-230/1/50  
1.30  
F.L. Amps  
Outdoor Coil - Type  
Rows - Fins/in. (Fins/mm)  
Face Area - ft2 (m2)  
Tube Size - in. (mm)  
Refrigerant  
Spine Fin™  
1 — 24 (1)  
14.93 (1.39)  
3
/8  
(10)  
R-225 - lbs. (kg)  
6 lbs, 11 oz. (3.03)  
Factory Supplied  
Line Size - O.D. Gas6 - in. (mm)  
Line Size - O.D. Liq.6 - in. (mm)  
Dimensions (H x W x D)  
Crated - in.  
Yes  
3
/
4
(20)  
5/16 (8)  
333/8 x 267/8 x 267/8  
(848 x 683 x 683)  
See Outline Dwg.  
- (mm)  
Uncrated  
Weight lbs. (kg)  
Shipping  
203 (92.1)  
193 (87.5)  
Net  
Notes:  
1Rated in accordance with ARI Standard 210/240.  
2Rated in accordance with ARI Standard 270.  
3Calculated in accordance with National Electric Code. Suitable for use with HACR circuit breakers or fuses.  
4Standard air — dry coil — outdoor.  
5This value approximate. For more precise value see unit nameplate and service instructions.  
6Max. linear length 80 ft.; max. lift — suction 60 ft.; max. lift — liquid 60 ft. Max. length of precharged tubing 50 ft. For greater  
length refer to Refrigerant Piping Manual Pub. No. 32-3009.  
8
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product  
Data  
Table 4 — TTA Product Specifications  
Model  
TTA030CD00A  
380-415/3/50  
TTA040CD00A  
380-415/3/50  
TTA050CD00A  
380-415/3/50  
TTA060CD00A  
380-415/3/50  
Power Conn. - Volts/Ph/Hz  
Fuse Size - max. amps  
Compressor - Type  
No. Used - No. Speeds  
Volts/Ph/Hz  
Per Local Codes  
Per Local Codes  
Per Local Codes  
Per Local Codes  
—————————— Climatuff® Reciprocating ——————————  
1 - 1  
380-415/3/50  
5.0  
1 - 1  
380-415/3/50  
7.0  
1 - 1  
380-415/3/50  
9.0  
1 - 1  
380-415/3/50  
10.6  
F.L. Amps1  
L.R. Amps  
51.0  
51.0  
71.0  
64.0  
Outdoor Fan - Type  
No. Used  
Propeller  
Propeller  
Propeller  
Propeller  
1
1
1
1
Diameter in. (mm)  
Type Drive - No. Speeds  
CFM @ 0.0 in. w.g.  
CMH @ 0.0 mm w.g.  
No. Motors - HP  
Motor Speed (RPM)  
Volts/Ph/Hz  
18 (457)  
Direct-1  
1815  
18 (457)  
Direct-1  
1845  
22 (559)  
Direct-1  
2225  
26 (660)  
Direct-1  
4250  
3083  
3134  
3780  
7220  
1 - 1/4  
1 - 1/4  
1 - 1/3  
1 - 1/3  
1 (900)  
400/1/50  
0.80  
1 (900)  
400/1/50  
0.80  
1 (690)  
400/1/50  
1.00  
1 (690)  
400/1/50  
1.70  
F.L. Amps  
Outdoor Coil - Type  
No. Rows - Fins/in.  
Face Area ft2 (m2)  
Tube Size in. (mm)  
Refrigerant  
Spine Fin™  
1 - 24  
Spine Fin™  
1 - 24  
Spine Fin™  
1 - 24  
Spine Fin™  
1 - 24  
12.22 (1.14)  
16.84 (1.57)  
25.50 (2.37)  
35.39 (3.29)  
3
3
3
3
/8  
(9.52)  
/8  
(9.52)  
/8  
(9.52)  
/8  
(9.52)  
R-222 - lbs. (kg)  
Line Size - OD Gas in. (mm)  
Line Size - OD Liq. in. (mm)  
Dimensions (H x W x D)  
Crated - in.  
5 Ibs, 12 oz. (2.61)  
7 Ibs, 2 oz. (3.23)  
9 Ibs, 2 oz. (4.14)  
13 Ibs, 0 oz. (5.90)  
7
/
8
(22.3)  
(9.52)  
11/8 (28.6)  
11/8 (28.6)  
11/8 (28.6)  
3
3
3
3
/
8
/8  
(9.52)  
/8  
(9.52)  
/8  
(9.52)  
25.0 x 30.0 x 26.5  
(635 x 762 x 673)  
24.3 x 28.3 x 24.6  
(617 x 719 x 625)  
33.3 x 30.0 x 26.5  
(846 x 762 x 673)  
32.8 x 28.3 x 24.6  
(833 x 719 x 625)  
41.3 x 34.8 x 31.3  
(1049 x 884 x 795)  
40.6 x 32.9 x 28.8  
(1031 x 836 x 732)  
45.5 x 41.0 x 37.0  
(1156 x 1041 x 940)  
44.8 x 38.9 x 34.8  
(1138 x 988 x 884)  
- (mm)  
Uncrated - in.  
- (mm)  
Weight- lbs. (kg)  
Shipping  
190.0 (86.2)  
181.0 (82.1)  
211.0 (95.7)  
200.0 (90.7)  
254.0 (115.2)  
239.0 (108.4)  
333.0 (151.0)  
314.0 (142.0)  
Net  
1At ARI system rating conditions of 80° F-DB/67° F-WB indoor & 95° F-DB outdoor.  
2Rated for 25 feet (7.5 meters) of evacuated refrigerant piping.  
TWE5-PRC000-EN  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Cooling  
English Units  
TTB524CA00A WITH TWE030CA40B  
TTB530CA00A WITH TWE030CA40B  
AT 900 CFM  
AT 1000 CFM  
GROSS CAPACITY IN BTU/H x 1000  
GROSS CAPACITY IN BTU/H x 1000  
O.D.  
I.D. TOTAL  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
O.D.  
I.D. TOTAL  
D.B. W.B. CAP.  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
29.0* 2.05  
D.B. W.B. CAP.  
72  
20.9  
17.6  
13.9  
10.2  
20.7  
17.4  
13.8  
10.0  
20.6  
17.3  
13.6  
9.9  
74  
76  
78  
80  
24.6*  
24.4  
20.7  
17.0  
24.3*  
24.2  
20.6  
72  
74  
76  
78  
80  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
22.9  
24.7  
26.6  
28.6  
22.6  
24.4  
26.2  
28.1  
22.3  
24.0  
25.8  
27.7  
21.5  
23.2  
24.9  
26.7  
20.8  
22.4  
24.0  
25.7  
19.3  
20.7  
22.2  
23.8  
22.6  
19.3  
15.6  
11.9  
22.4  
19.1  
15.5  
11.7  
22.3*  
19.0  
15.3  
11.6  
21.7*  
18.6  
14.9  
11.2  
21.1*  
18.3  
14.6  
10.8  
19.8*  
17.6  
13.9  
10.1  
23.4*  
21.0  
17.3  
13.6  
23.1*  
20.8  
17.2  
13.4  
22.9*  
20.7  
17.0  
13.3  
22.3*  
20.3  
16.6  
12.9  
21.6*  
20.0  
16.3  
12.5  
20.3*  
19.3  
15.6  
11.8  
24.0*  
22.7  
19.0  
15.3  
23.8*  
22.5  
18.9  
15.1  
23.5*  
22.4  
18.7  
15.0  
22.8*  
22.0  
18.4  
14.6  
22.2*  
21.7  
18.0  
14.2  
20.8*  
20.8*  
17.3  
13.5  
1.90  
1.97  
2.04  
2.11  
2.01  
2.07  
2.14  
2.21  
2.11  
2.18  
2.25  
2.32  
2.20  
2.26  
2.33  
2.40  
2.29  
2.35  
2.41  
2.48  
2.47  
2.53  
2.58  
2.64  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
27.4  
29.5  
31.6  
33.9  
27.1  
29.1  
31.2  
33.4  
26.7  
28.7  
30.8  
33.0  
25.8  
27.8  
29.8  
31.9  
25.0  
26.8  
28.8  
30.8  
23.2  
25.0  
26.7  
28.6  
24.2  
20.5  
16.5  
12.3  
24.1  
20.4  
16.3  
12.1  
23.9  
20.2  
16.1  
11.9  
23.5  
19.8  
15.7  
11.5  
23.1  
19.4  
15.3  
11.1  
22.3  
18.6  
14.5  
10.3  
26.1  
22.4  
18.4  
14.2  
25.9  
22.3  
18.2  
14.0  
25.8  
22.1  
18.0  
13.8  
25.4  
21.7  
17.6  
13.4  
25.0  
21.3  
17.2  
13.0  
23.5*  
20.4  
16.3  
12.2  
27.6*  
24.3  
20.2  
16.1  
27.3*  
24.1  
20.1  
15.9  
27.0*  
24.0  
19.9  
15.7  
26.3*  
23.6  
19.5  
15.3  
25.6*  
23.1  
19.1  
14.9  
24.2*  
22.3  
18.2  
14.0  
28.3*  
26.2  
22.1  
18.0  
28.0*  
26.0  
21.9  
17.8  
27.7*  
25.9  
21.8  
17.6  
27.0*  
25.4  
21.4  
17.2  
26.3*  
25.0  
20.9  
16.8  
24.7*  
24.2  
20.1  
15.9  
85  
90  
85  
90  
28.1  
24.0  
19.8  
2.12  
2.20  
2.28  
28.7* 2.15  
27.9  
23.8  
19.7  
28.4*  
27.7  
23.7  
19.5  
2.23  
2.31  
2.39  
2.25  
2.33  
2.41  
2.49  
16.8  
24.0*  
24.0*  
20.4  
95  
95  
16.7  
20.2  
16.9  
13.2  
9.5  
19.9  
16.6  
12.9  
9.1  
23.4*  
23.4*  
20.1  
27.6* 2.34  
100  
105  
115  
100  
105  
115  
27.3  
23.2  
19.1  
26.6*  
2.42  
2.50  
2.58  
2.43  
16.3  
22.7*  
22.7*  
19.7  
26.9* 2.51  
22.8  
18.6  
2.59  
2.67  
25.3* 2.62  
25.3* 2.69  
15.9  
19.2  
15.9  
12.2  
8.4  
21.3*  
21.3*  
19.0  
22.0  
17.8  
2.77  
2.84  
15.2  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
775  
X0.98  
X0.99  
1025  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
775  
X0.94  
1025  
X1.06  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1000  
X1.00  
X1.00  
1000  
X1.00  
X1.00  
AIRFLOW  
SENS. CAP.  
1000  
X1.00  
1000  
X1.00  
VALUES AT 95/80/67 RATING CONDITIONS  
GROSS CAPACITY = 25800 BTUH  
AIRFLOW = 900 CFM  
COMPRESSOR POWER = 2245 WATTS  
I.D. FAN POWER = 425 WATTS  
O.D. FAN POWER = 165 WATTS  
S.E.E.R. = 8.71 BTUH/WATT  
VALUES AT 95/80/67 RATING CONDITIONS  
GROSS CAPACITY = 30800 BTUH  
AIRFLOW = 1000 CFM  
COMPRESSOR POWER = 2410 WATTS  
I.D. FAN POWER = 440 WATTS  
O.D. FAN POWER = 170 WATTS  
S.E.E.R. = 9.80 BTUH/WATT  
E.E.R. = 9.10 BTUH/WATT  
E.E.R. = 10.20 BTUH/WATT  
NOTE: RATED WITH 25 FEET OF 3/4 SUCTION AND 5/16 LIQUID LINE  
NOTE: RATED WITH 25 FEET OF 3/4 SUCTION AND 5/16 LIQUID LINE  
10  
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Cooling  
Metric Units  
TTB524CA00A WITH TWE030CA40B  
TTB530CA00A WITH TWE030CA40B  
AT 1528 CMH  
AT 1700 CMH  
GROSS CAPACITY IN KILOWATTS  
GROSS CAPACITY IN KILOWATTS  
O.D.  
I.D. TOTAL  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
O.D.  
I.D. TOTAL  
D.B. W.B. CAP.  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
D.B. W.B. CAP.  
22.2  
6.1  
5.2  
4.1  
3.0  
6.1  
5.1  
4.0  
2.9  
6.0  
5.1  
4.0  
2.9  
5.9  
5.0  
3.9  
2.8  
5.8  
4.9  
3.8  
2.7  
5.6  
4.7  
3.6  
2.5  
23.3  
6.6  
5.7  
4.6  
3.5  
6.6  
5.6  
4.5  
3.4  
24.4  
6.9*  
25.6  
7.0*  
26.7  
7.2*  
22.2  
7.1  
6.0  
4.8  
3.6  
7.1  
6.0  
4.8  
3.5  
7.0  
5.9  
4.7  
3.5  
6.9  
5.8  
4.6  
3.4  
6.8  
5.7  
4.5  
3.3  
6.5  
5.4  
4.2  
3.0  
23.3  
7.6  
6.6  
5.4  
4.2  
7.6  
6.5  
5.3  
4.1  
7.6  
6.5  
5.3  
4.0  
7.4  
6.4  
5.2  
3.9  
24.4  
8.1*  
25.6  
8.3*  
26.7  
8.5*  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
6.7  
7.2  
7.8  
8.4  
6.6  
7.1  
7.7  
8.2  
6.5  
7.0  
7.6  
8.1  
6.3  
6.8  
7.3  
7.8  
6.1  
6.6  
7.0  
7.5  
5.7  
6.1  
6.5  
7.0  
1.90  
1.97  
2.04  
2.11  
2.01  
2.07  
2.14  
2.21  
2.11  
2.18  
2.25  
2.32  
2.20  
2.26  
2.33  
2.40  
2.29  
2.35  
2.41  
2.48  
2.47  
2.53  
2.58  
2.64  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
8.0  
8.6  
9.3  
9.9  
7.9  
8.5  
9.1  
9.8  
7.8  
8.4  
9.0  
9.7  
7.6  
8.1  
8.7  
9.3  
7.3  
7.9  
8.4  
9.0  
6.8  
7.3  
7.8  
8.4  
2.05  
2.12  
2.20  
2.28  
2.15  
2.23  
2.31  
2.39  
2.25  
2.33  
2.41  
2.49  
2.34  
2.42  
2.50  
2.58  
2.43  
2.51  
2.59  
2.67  
2.62  
2.69  
2.77  
2.84  
29.4  
32.2  
35.0  
37.8  
40.6  
46.1  
6.2  
5.1  
4.0  
6.8*  
6.1  
5.0  
3.9  
6.7*  
6.1  
5.0  
3.9  
6.5*  
5.9  
4.9  
3.8  
6.3*  
5.9  
4.8  
3.7  
5.9*  
5.7  
4.6  
3.5  
6.7  
5.6  
4.5  
7.0*  
6.6  
5.5  
4.4  
6.9*  
6.6  
5.5  
4.4  
6.7*  
6.4  
5.4  
4.3  
6.5*  
6.4  
5.3  
4.2  
6.1*  
6.1  
5.1  
4.0  
7.1  
6.1  
5.0  
7.1*  
7.1  
6.0  
4.9  
7.0*  
7.0  
6.0  
4.9  
6.9*  
6.9  
5.9  
4.8  
6.7*  
6.7  
5.8  
4.7  
6.2*  
6.2  
5.6  
4.5  
29.4  
32.2  
35.0  
37.8  
40.6  
46.1  
7.1  
5.9  
4.7  
8.0*  
7.1  
5.9  
4.7  
7.9*  
7.0  
5.8  
4.6  
7.7*  
6.9  
5.7  
4.5  
7.5*  
6.8  
5.6  
4.4  
7.1*  
6.5  
5.3  
4.1  
7.7  
6.5  
5.3  
8.2*  
7.6  
6.4  
5.2  
8.1*  
7.6  
6.4  
5.2  
7.9*  
7.4  
6.3  
5.0  
7.7*  
7.3  
6.1  
4.9  
7.2*  
7.1  
5.9  
4.7  
8.2  
7.0  
5.8  
8.4*  
8.2  
7.0  
5.8  
8.3*  
8.1  
6.9  
5.7  
8.1*  
8.0  
6.8  
5.6  
2.0*  
7.9  
6.7  
5.4  
7.4*  
7.4  
6.4  
5.2  
6.5*  
5.6  
4.5  
3.4  
6.4*  
5.4  
4.4  
3.3  
6.2*  
5.4  
4.3  
3.2  
5.8*  
5.2  
4.1  
3.0  
7.3*  
6.2  
5.0  
3.8  
6.9*  
6.0  
4.8  
3.6  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
0.368  
X0.98  
X0.99  
0.486  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
0.368  
X0.94  
0.486  
X1.06  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
0.472  
X1.00  
X1.00  
0.472  
X1.00  
X1.00  
AIRFLOW  
SENS. CAP.  
0.472  
X1.00  
0.472  
X1.00  
VALUES AT ARI RATING CONDITIONS  
GROSS CAPACITY = 7.54 KW  
AIRFLOW = 0.42 CMS  
VALUES AT ARI RATING CONDITIONS  
GROSS CAPACITY = 9.02 KW  
AIRFLOW = 0.47 CMS  
AIRFLOW = 900. CFM  
AIRFLOW = 1000. CFM  
COMPRESSOR POWER = 2245 WATTS  
I.D. FAN POWER = 425 WATTS  
O.D. FAN POWER = 165 WATTS  
COP = 2.67  
COMPRESSOR POWER = 2410 WATTS  
I.D. FAN POWER = 440 WATTS  
O.D. FAN POWER = 170 WATTS  
COP = 2.99  
EER = 9.10 BTU/WATT  
EER = 10.20 BTU/WATT  
NOTE: RATED WITH 7.62 METERS OF 3/4 IN. SUCTION AND 5/16 IN. LIQUID LINES  
NOTE: RATED WITH 7.62 METERS OF 3/4 IN. SUCTION AND 5/16 IN. LIQUID LINES  
TWE5-PRC000-EN  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Cooling  
English Units  
TTB530CA00A WITH TWE040CA40C  
TTB536CA00A WITH TWE040CA40C  
AT 1200 CFM  
AT 1200 CFM  
GROSS CAPACITY IN BTU/H x 1000  
GROSS CAPACITY IN BTU/H x 1000  
O.D.  
I.D. TOTAL  
D.B. W.B. CAP.  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
O.D.  
I.D. TOTAL  
D.B. W.B. CAP.  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
72  
74  
76  
78  
80  
72  
74  
76  
78  
80  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
29.1  
31.2  
33.4  
35.7  
28.7  
30.8  
32.9  
35.1  
28.3  
30.3  
32.4  
34.6  
27.4  
29.3  
31.3  
33.4  
26.5  
28.3  
30.2  
32.2  
24.6  
26.3  
28.1  
29.9  
27.5  
22.9  
17.8  
12.7  
27.3  
22.7  
17.6  
12.5  
27.1  
22.5  
17.4  
12.3  
26.7  
22.1  
17.0  
11.9  
26.3  
21.7  
16.6  
11.4  
24.8*  
20.8  
15.7  
10.6  
29.3*  
25.2  
20.2  
15.0  
29.0*  
25.0  
20.0  
14.8  
28.6*  
24.8  
19.8  
14.6  
27.9*  
24.4  
19.3  
14.2  
27.1*  
24.0  
18.9  
13.8  
25.5*  
23.1  
18.1  
12.9  
30.1*  
27.5  
22.5  
17.4  
29.7*  
27.3  
22.3  
17.2  
29.4*  
27.1  
22.1  
16.9  
28.6*  
26.7  
21.7  
16.5  
27.8*  
26.3  
21.2  
16.1  
26.1*  
25.5  
20.4  
15.2  
30.8*  
29.9  
24.8  
19.7  
30.4*  
29.7  
24.6  
19.5  
30.1*  
29.5  
24.4  
19.3  
29.2*  
29.0  
24.0  
18.8  
28.4*  
28.4*  
23.6  
18.4  
26.7*  
26.7*  
22.7  
17.6  
31.5* 2.18  
31.5* 2.26  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
35.2  
37.8  
40.5  
43.3  
34.6  
37.1  
39.8  
42.5  
33.9  
36.4  
39.0  
41.7  
32.7  
35.1  
37.6  
40.2  
31.5  
33.8  
36.2  
38.7  
29.1  
31.2  
33.4  
35.7  
30.5  
25.9  
20.9  
15.7  
30.2  
25.6  
20.5  
15.4  
29.9  
25.3  
20.2  
15.0  
29.3  
24.7  
19.7  
14.5  
28.8  
24.2  
19.1  
13.9  
27.6  
23.0  
18.0  
12.8  
32.8  
28.3  
23.2  
18.0  
32.5  
27.9  
22.9  
17.7  
32.2  
27.6  
22.6  
17.4  
31.7  
27.1  
22.0  
16.8  
31.1  
26.5  
21.4  
16.2  
29.4*  
25.4  
20.3  
15.1  
35.2  
30.6  
25.5  
20.4  
34.7*  
30.3  
25.2  
20.0  
34.1*  
30.0  
24.9  
19.7  
33.2*  
29.4  
24.3  
19.2  
32.2*  
28.8  
23.8  
18.6  
30.2*  
27.7  
22.6  
17.5  
36.0*  
32.9  
27.9  
22.7  
35.5*  
32.6  
27.6  
22.4  
35.0*  
32.3  
27.2  
22.1  
34.0*  
31.7  
26.7  
21.5  
33.0*  
31.2  
26.1  
20.9  
30.9*  
30.0  
25.0  
19.8  
36.9* 2.61  
85  
90  
85  
90  
35.3  
30.2  
25.0  
2.72  
2.83  
2.94  
27.1  
22.0  
2.34  
2.42  
31.1* 2.29  
31.1* 2.37  
36.4* 2.75  
35.0  
29.9  
24.7  
2.85  
2.96  
3.08  
26.9  
21.8  
2.45  
2.54  
30.7* 2.40  
30.7* 2.48  
35.8* 2.88  
95  
95  
34.6  
29.6  
24.4  
2.99  
3.10  
3.21  
26.7  
21.6  
2.56  
2.65  
29.9* 2.49  
29.9* 2.57  
34.8* 2.98  
100  
105  
115  
100  
105  
115  
34.1  
29.0  
23.8  
3.09  
3.20  
3.31  
26.3  
21.2  
2.65  
2.74  
29.0* 2.58  
29.0* 2.66  
33.7* 3.08  
33.5  
28.4  
23.3  
3.18  
3.29  
3.40  
25.9  
20.7  
2.74  
2.83  
27.3* 2.76  
27.3* 2.84  
31.6* 3.29  
31.6* 3.38  
25.0  
19.9  
2.92  
3.01  
27.3  
22.1  
3.48  
3.59  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1200  
X1.00  
X1.00  
1200  
X1.00  
X1.00  
AIRFLOW  
SENS. CAP.  
1200  
X1.00  
1200  
X1.00  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1200  
X1.00  
X1.00  
1200  
X1.00  
X1.00  
AIRFLOW  
SENS. CAP.  
1200  
X1.00  
1200  
X1.00  
VALUES AT 95/80/67 RATING CONDITIONS  
VALUES AT 95/80/67 RATING CONDITIONS  
GROSS CAPACITY = 32400 BTUH  
AIRFLOW = 1200 CFM  
COMPRESSOR POWER = 2562 WATTS  
I.D. FAN POWER = 325 WATTS  
O.D. FAN POWER = 170 WATTS  
S.E.E.R. = 10.82 BTUH/WATT  
E.E.R. = 10.60 BTUH/WATT  
GROSS CAPACITY = 39000 BTUH  
AIRFLOW = 1200 CFM  
COMPRESSOR POWER = 3099 WATTS  
I.D. FAN POWER = 325 WATTS  
O.D. FAN POWER = 170 WATTS  
S.E.E.R. = 10.95 BTUH/WATT  
E.E.R. = 10.85 BTUH/WATT  
NOTE: RATED WITH 25 FEET OF 3/4 SUCTION AND 5/16 LIQUID LINE  
NOTE: RATED WITH 25 FEET OF 3/4 SUCTION AND 5/16 LIQUID LINE  
12  
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Cooling  
Metric Units  
TTB530CA00A WITH TWE040CA40C  
TTB536CA00A WITH TWE040CA40C  
AT 2039 CMH  
AT 2039 CMH  
GROSS CAPACITY IN KILOWATTS  
GROSS CAPACITY IN KILOWATTS  
O.D.  
I.D. TOTAL  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
O.D.  
I.D. TOTAL  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
D.B. W.B. CAP.  
22.2  
8.1  
6.7  
5.2  
3.7  
8.0  
6.7  
5.2  
3.7  
7.9  
6.6  
5.1  
3.6  
7.8  
6.5  
5.0  
3.5  
7.7  
6.4  
4.9  
3.3  
23.3  
8.6*  
24.4  
8.8*  
25.6  
9.0*  
8.8  
7.3  
5.8  
8.9*  
8.7  
7.2  
5.7  
8.8*  
8.6  
7.1  
5.7  
8.6*  
8.5  
26.7  
9.2*  
9.2*  
7.9  
D.B. W.B. CAP.  
22.2  
8.9  
7.6  
6.1  
4.6  
8.8  
7.5  
6.0  
4.5  
8.8  
7.4  
5.9  
4.4  
8.6  
7.2  
5.8  
4.2  
8.4  
7.1  
5.6  
4.1  
8.1  
6.7  
5.3  
3.8  
23.3  
9.6  
8.3  
6.8  
5.3  
9.5  
8.2  
6.7  
5.2  
9.4  
8.1  
6.6  
5.1  
9.3  
7.9  
6.4  
4.9  
9.1  
7.8  
6.3  
4.7  
24.4  
10.3  
9.0  
25.6  
10.5*  
9.6  
26.7  
10.8*  
10.3  
8.8  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
8.5  
9.1  
9.8  
10.5  
8.4  
9.0  
9.6  
10.3  
8.3  
8.9  
9.5  
10.1  
8.0  
8.6  
9.2  
9.8  
7.8  
8.3  
8.8  
9.4  
7.2  
7.7  
8.2  
8.8  
2.18  
2.26  
2.34  
2.42  
2.29  
2.37  
2.45  
2.54  
2.40  
2.48  
2.56  
2.65  
2.49  
2.57  
2.65  
2.74  
2.58  
2.66  
2.74  
2.83  
2.76  
2.84  
2.92  
3.01  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
10.3  
11.1  
11.9  
12.7  
10.1  
10.9  
11.7  
12.5  
9.9  
10.7  
11.4  
12.2  
9.6  
2.61  
2.72  
2.83  
2.94  
2.75  
2.85  
2.96  
3.08  
2.88  
2.99  
3.10  
3.21  
2.98  
3.09  
3.20  
3.31  
3.08  
3.18  
3.29  
3.40  
3.29  
3.38  
3.48  
3.59  
29.4  
32.2  
35.0  
37.8  
40.6  
46.1  
7.4  
5.9  
4.4  
8.5*  
7.3  
5.9  
4.3  
8.4*  
7.3  
5.8  
4.3  
8.2*  
7.1  
5.7  
4.2  
7.9*  
7.0  
5.5  
4.0  
7.5*  
6.8  
5.3  
3.8  
8.1  
6.6  
5.1  
8.7*  
8.0  
6.5  
5.0  
8.6*  
7.9  
6.5  
5.0  
8.4*  
7.8  
6.4  
4.8  
8.1*  
7.7  
6.2  
4.7  
7.6*  
7.5  
6.0  
4.5  
29.4  
32.2  
35.0  
37.8  
40.6  
46.1  
7.5  
8.2  
6.4  
6.0  
10.2*  
8.9  
7.4  
5.9  
10.0*  
8.8  
7.3  
5.8  
9.7*  
8.6  
7.1  
5.6  
9.4*  
8.4  
6.7  
10.4*  
9.6  
8.1  
6.6  
10.3*  
9.5  
8.0  
6.5  
10.0*  
9.3  
7.8  
6.3  
9.7*  
9.1  
7.3  
9.1*  
9.1*  
7.9  
10.7*  
10.3  
8.8  
6.4  
7.2  
9.0*  
9.0*  
7.8  
10.5*  
10.1  
8.7  
6.3  
7.1  
8.8*  
8.8*  
7.7  
10.2*  
10.0  
8.5  
7.0  
9.9*  
9.8  
8.3  
6.8  
10.3  
11.0  
11.8  
9.2  
7.0  
5.5  
6.2  
8.3*  
8.3*  
6.9  
8.5*  
8.5*  
7.6  
6.1  
8.0*  
8.0  
7.3  
5.8  
9.9  
10.6  
11.3  
8.5  
9.1  
9.8  
7.0  
5.4  
8.8*  
8.1  
6.6  
5.1  
7.6  
6.1  
9.1*  
8.8  
7.3  
5.8  
5.4  
7.3*  
7.8*  
7.8  
6.7  
8.6*  
9.3*  
9.3*  
8.0  
6.1  
4.6  
3.1  
7.4  
5.9  
4.4  
5.2  
10.5  
6.5  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
AIRFLOW  
566  
566  
AIRFLOW  
566  
566  
AIRFLOW  
566  
566  
AIRFLOW  
566  
566  
TOTAL CAP.  
COMPR. KW  
X1.00  
X1.00  
X1.00  
X1.00  
SENS. CAP.  
X1.00  
X1.00  
TOTAL CAP.  
COMPR. KW  
X1.00  
X1.00  
X1.00  
X1.00  
SENS. CAP.  
X1.00  
X1.00  
VALUES AT ARI RATING CONDITIONS  
VALUES AT ARI RATING CONDITIONS  
GROSS CAPACITY = 9.48 KW  
AIRFLOW = 0.57 CMS  
COMPRESSOR POWER = 2562WATTS  
I.D. FAN POWER = 325 WATTS  
O.D. FAN POWER = 170 WATTS  
COP = 3.11  
GROSS CAPACITY = 11.41 KW  
AIRFLOW = 0.57 CMS  
COMPRESSOR POWER = 3099 WATTS  
I.D. FAN POWER = 325 WATTS  
O.D. FAN POWER = 170 WATTS  
COP = 3.18  
EER = 10.60 BTU/WATT  
EER = 10.85 BTU/WATT  
NOTE: RATED WITH 7.62 METERS OF 3/4 IN. SUCTION AND 5/16 IN. LIQUID LINES  
NOTE: RATED WITH 7.62 METERS OF 3/4 IN. SUCTION AND 5/16 IN. LIQUID LINES  
TWE5-PRC000-EN  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Cooling  
English Units  
TTA030CD WITH TWE030CA4  
TTA030CD WITH TWE040CA4-B  
AT 1000 CFM  
AT 1125 CFM  
GROSS CAPACITY IN BTU/H x 1000  
GROSS CAPACITY IN BTU/H x 1000  
O.D.  
I.D. TOTAL  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
O.D.  
I.D. TOTAL  
D.B. W.B. CAP.  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
30.7* 2.34  
D.B. W.B. CAP.  
72  
74  
76  
78  
80  
72  
74  
76  
78  
80  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
27.3  
29.5  
31.7  
34.1  
26.8  
28.9  
31.1  
33.4  
26.3  
28.3  
30.5  
32.7  
25.6  
27.6  
29.7  
31.8  
24.9  
26.9  
28.9  
31.0  
23.6  
25.4  
27.3  
29.2  
21.8  
18.5  
14.9  
11.2  
21.6  
18.3  
14.7  
10.9  
21.4  
18.1  
14.4  
10.7  
21.1  
17.8  
14.1  
10.4  
20.8  
17.5  
13.8  
10.1  
20.2  
16.9  
13.2  
9.5  
23.5  
20.2  
16.6  
12.9  
23.3  
20.0  
16.4  
12.6  
23.1  
19.8  
16.1  
12.4  
22.8  
19.5  
15.8  
12.1  
22.5  
19.2  
15.5  
11.8  
21.9  
18.6  
14.9  
11.2  
25.2  
21.9  
18.3  
14.6  
25.0  
21.7  
18.1  
14.3  
24.8  
21.5  
17.8  
14.1  
24.5  
21.2  
17.5  
13.8  
24.2  
20.9  
17.2  
13.5  
23.7*  
20.3  
16.6  
12.9  
26.9  
23.6  
20.0  
16.3  
26.7  
23.4  
19.8  
16.0  
26.4*  
23.2  
19.5  
15.8  
25.9*  
22.9  
19.2  
15.5  
25.3*  
22.6  
18.9  
15.2  
24.2*  
22.0  
18.3  
14.6  
27.9* 2.27  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
29.4  
31.7  
34.0  
36.5  
28.8  
31.0  
33.3  
35.6  
28.2  
30.3  
32.5  
34.8  
27.4  
29.4  
31.5  
33.8  
26.6  
28.5  
30.6  
32.7  
25.0  
26.8  
28.7  
30.6  
24.8  
20.9  
16.5  
12.1  
24.6  
20.6  
16.2  
11.8  
24.3  
20.3  
15.9  
11.5  
23.9  
20.0  
15.6  
11.1  
23.6  
19.6  
15.2  
10.8  
22.9  
18.9  
14.5  
10.0  
26.8  
22.9  
18.5  
14.1  
26.6  
22.6  
18.2  
13.8  
26.3  
22.3  
18.0  
13.5  
26.0  
22.0  
17.6  
13.1  
25.6  
21.6  
17.3  
12.8  
25.0  
21.0  
16.6  
12.1  
28.9  
24.9  
20.6  
16.1  
28.6  
24.6  
20.3  
15.8  
28.3*  
24.4  
20.0  
15.5  
27.7*  
24.0  
19.6  
15.2  
27.0*  
23.7  
19.3  
14.8  
25.7*  
23.0  
18.6  
14.1  
30.0*  
27.0  
22.6  
18.1  
29.5*  
26.7  
22.3  
17.8  
29.0*  
26.4  
22.0  
17.6  
28.3*  
26.0  
21.7  
17.2  
27.6*  
25.7  
21.3  
16.8  
26.3*  
25.0  
20.6  
16.1  
85  
90  
25.3  
21.7  
18.0  
2.35  
2.43  
2.51  
85  
90  
29.0  
24.6  
20.2  
2.42  
2.50  
2.59  
27.5* 2.38  
30.2* 2.45  
25.1  
21.5  
17.7  
2.46  
2.54  
2.63  
28.7  
24.3  
19.9  
2.53  
2.62  
2.71  
27.1* 2.49  
29.7* 2.57  
95  
24.9  
21.2  
17.5  
2.57  
2.65  
2.74  
95  
28.4  
24.0  
19.6  
2.65  
2.73  
2.82  
26.5* 2.61  
29.0* 2.69  
100  
105  
115  
24.6  
20.9  
17.2  
2.69  
2.77  
2.85  
100  
105  
115  
28.1  
23.7  
19.2  
2.77  
2.85  
2.94  
26.0* 2.73  
28.3* 2.81  
24.3  
20.6  
16.9  
2.80  
2.88  
2.96  
27.7  
23.3  
18.9  
2.89  
2.97  
3.05  
24.8* 2.97  
26.9* 3.06  
23.7  
20.0  
16.3  
3.04  
3.11  
3.19  
26.9*  
22.6  
18.2  
3.13  
3.20  
3.28  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
975  
X0.98  
X0.99  
1275  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
975  
X0.94  
1275  
X1.06  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
975  
X0.98  
X0.99  
1275  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
975  
X0.94  
1275  
X1.06  
VALUES AT 95/80/67 RATING CONDITIONS  
VALUES AT 95/80/67 RATING CONDITIONS  
GROSS CAPACITY = 32500 BTUH  
AIRFLOW = 1125 CFM  
GROSS CAPACITY = 32500 BTUH  
AIRFLOW = 1125 CFM  
COMPRESSOR POWER = 2733 WATTS  
I.D. FAN POWER = 290 WATTS  
O.D. FAN POWER = 227 WATTS  
E.E.R. = 9.60 BTUH/WATT  
COMPRESSOR POWER = 2733 WATTS  
I.D. FAN POWER = 290 WATTS  
O.D. FAN POWER = 227 WATTS  
E.E.R. = 9.60 BTUH/WATT  
NOTE: RATED WITH 25 FEET OF 7/8 SUCTION AND 3/8 LIQUID LINE  
NOTE: RATED WITH 25 FEET OF 7/8 SUCTION AND 3/8 LIQUID LINE  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
14  
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Cooling  
Metric Units  
TTA030CD00A WITH TWE030CA40B  
TTA030CD00A WITH TWE040CA40C  
AT 1700 CMH  
AT 1911 CMH  
GROSS CAPACITY IN KILOWATTS  
GROSS CAPACITY IN KILOWATTS  
O.D.  
I.D. TOTAL  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
O.D.  
I.D. TOTAL  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
D.B. W.B. CAP.  
22.2  
6.4  
5.4  
4.4  
3.3  
6.3  
5.4  
4.3  
3.2  
6.3  
5.3  
4.2  
3.1  
6.2  
5.2  
4.1  
3.0  
6.1  
5.1  
4.0  
3.0  
5.9  
5.0  
3.9  
2.8  
23.3  
6.9  
5.9  
4.9  
3.8  
6.8  
5.9  
4.8  
3.7  
6.8  
5.8  
4.7  
3.6  
6.7  
5.7  
4.6  
3.5  
6.6  
5.6  
4.5  
3.5  
6.4  
5.4  
4.4  
3.3  
24.4  
7.4  
6.4  
5.4  
4.3  
7.3  
6.4  
5.3  
4.2  
7.3  
6.3  
5.2  
4.1  
7.2  
6.2  
5.1  
4.0  
7.1  
6.1  
5.0  
4.0  
25.6  
7.9  
6.9  
5.9  
4.8  
7.8  
6.9  
5.8  
4.7  
26.7  
8.2*  
D.B. W.B. CAP.  
22.2  
7.3  
6.1  
4.8  
3.5  
7.2  
6.0  
4.7  
3.5  
7.1  
5.9  
4.7  
3.4  
7.0  
5.9  
4.6  
3.3  
6.9  
5.7  
4.5  
3.2  
6.7  
5.5  
4.2  
2.9  
23.3  
7.9  
6.7  
5.4  
4.1  
7.8  
6.6  
5.3  
4.0  
7.7  
6.5  
5.3  
4.0  
7.6  
6.4  
5.2  
3.8  
7.5  
6.3  
5.1  
3.8  
7.3  
6.2  
4.9  
3.5  
24.4  
8.5  
7.3  
6.0  
4.7  
8.4  
7.2  
5.9  
4.6  
25.6  
8.8*  
26.7  
9.0*  
8.5  
7.2  
5.9  
8.8*  
8.4  
7.1  
5.8  
8.7*  
8.3  
7.0  
5.7  
8.5*  
8.2  
6.9  
5.6  
8.3*  
8.1  
6.8  
5.5  
7.9*  
7.9*  
6.6  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
8.0  
8.6  
9.3  
10.0  
7.9  
8.5  
9.1  
9.8  
7.7  
8.3  
8.9  
9.6  
7.5  
8.1  
8.7  
9.3  
7.3  
7.9  
8.5  
9.1  
6.9  
7.4  
8.0  
8.6  
2.27  
2.35  
2.43  
2.51  
2.38  
2.46  
2.54  
2.63  
2.49  
2.57  
2.65  
2.74  
2.61  
2.69  
2.77  
2.85  
2.73  
2.80  
2.88  
2.96  
2.97  
3.04  
3.11  
3.19  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
8.6  
9.3  
10.0  
10.7  
8.4  
9.1  
9.8  
10.4  
8.3  
8.9  
9.5  
10.2  
8.0  
8.6  
9.2  
9.9  
7.8  
8.4  
9.0  
9.6  
7.3  
7.9  
8.4  
9.0  
2.34  
2.42  
2.50  
2.59  
2.45  
2.53  
2.62  
2.71  
2.57  
2.65  
2.73  
2.82  
2.69  
2.77  
2.85  
2.94  
2.81  
2.89  
2.97  
3.05  
3.06  
3.13  
3.20  
3.28  
29.4  
32.2  
35.0  
37.8  
40.6  
46.1  
7.4  
6.4  
5.3  
8.1*  
7.4  
6.3  
5.2  
7.9*  
7.3  
6.2  
5.1  
7.8*  
7.2  
6.1  
5.0  
7.6*  
7.1  
6.0  
5.0  
7.3*  
6.9  
5.9  
4.8  
29.4  
32.2  
35.0  
37.8  
40.6  
46.1  
7.9  
6.6  
5.3  
8.6*  
7.8  
6.5  
5.2  
8.5*  
7.7  
6.4  
5.2  
8.3*  
7.6  
6.4  
5.0  
8.1*  
7.5  
6.2  
4.9  
7.7*  
7.3  
6.0  
4.7  
7.7*  
8.3*  
6.8  
5.7  
4.6  
7.6*  
6.7  
5.6  
4.5  
7.4*  
6.6  
5.5  
4.5  
7.1*  
6.4  
5.4  
4.3  
7.1  
5.9  
4.5  
8.1*  
7.0  
5.7  
4.5  
7.9*  
6.9  
5.7  
4.3  
7.5*  
6.7  
5.4  
4.1  
6.9*  
5.9  
4.9  
3.8  
5.3  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
975  
X0.98  
X0.99  
1275  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
975  
X0.94  
1275  
X1.06  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
975  
X0.98  
X0.99  
1275  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
975  
X0.94  
1275  
X1.06  
VALUES AT 95/80/67 RATING CONDITIONS  
VALUES AT 95/80/67 RATING CONDITIONS  
GROSS CAPACITY = 8.94 KW  
AIRFLOW = 0.57 CMS  
COMPRESSOR POWER = 2653 WATTS  
I.D. FAN POWER = 430 WATTS  
O.D. FAN POWER = 227 WATTS  
EER = 8.75 BTU/WATT  
GROSS CAPACITY = 9.5 KW  
AIRFLOW = 1913 CMH  
COMPRESSOR POWER = 2653 WATTS  
I.D. FAN POWER = 430 WATTS  
O.D. FAN POWER = 227 WATTS  
EER = 8.75 BTU/WATT  
NOTE: RATED WITH 7.62 METERS OF 7/8 IN. SUCTION AND 7/8 IN. LIQUID LINES  
NOTE: RATED WITH 7.62 METERS OF 7/8 IN. SUCTION AND 7/8 IN. LIQUID LINES  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
TWE5-PRC000-EN  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Cooling  
English Units  
TTA040CD WITH TWE040CA4B  
TTA040CD WITH TWE050CA5C  
AT 1325 CFM  
AT 1600 CFM  
GROSS CAPACITY IN BTU/H x 1000  
GROSS CAPACITY IN BTU/H x 1000  
O.D.  
D.B.  
I.D. GROSS  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
O.D.  
D.B.  
I.D. GROSS  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
41.3* 42.2* 3.16  
W.B.  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
CAP.  
36.9  
39.7  
42.6  
45.6  
36.2  
38.9  
41.7  
44.6  
35.4  
38.0  
40.8  
43.6  
34.5  
37.0  
39.7  
42.4  
33.5  
36.0  
38.6  
41.2  
31.6  
33.9  
36.3  
38.8  
72  
74  
76  
78  
80  
W.B.  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
CAP.  
40.5  
43.4  
46.4  
49.5  
39.4  
42.2  
45.1  
48.2  
38.4  
41.1  
43.9  
46.8  
37.3  
39.9  
42.6  
45.4  
36.1  
38.7  
41.3  
44.0  
33.9  
36.2  
38.7  
41.2  
72  
74  
76  
78  
80  
29.5  
25.0  
20.0  
14.9  
29.2  
24.7  
19.7  
14.6  
28.9  
24.3  
19.3  
14.2  
28.5  
23.9  
18.9  
13.8  
28.1  
23.5  
18.5  
13.4  
27.3  
22.7  
17.7  
12.6  
31.8  
27.3  
22.3  
17.2  
31.5  
27.0  
22.0  
16.9  
31.2  
26.6  
21.7  
16.6  
30.8  
26.2  
21.2  
16.1  
30.4  
25.8  
20.8  
15.7  
29.6  
25.0  
20.0  
14.9  
34.1  
29.6  
24.6  
19.6  
33.8  
29.3  
24.3  
19.2  
33.5  
29.0  
24.0  
18.9  
33.1  
28.5  
23.5  
18.4  
32.7  
28.1  
23.1  
18.0  
31.8*  
27.3  
22.3  
17.2  
36.4  
31.9  
26.9  
21.9  
36.1  
31.6  
26.6  
21.5  
37.7* 3.24  
34.2  
28.6  
22.5  
16.2  
33.8  
28.2  
22.0  
15.8  
33.3  
27.7  
21.6  
15.3  
32.9  
27.3  
21.1  
14.8  
32.4  
26.8  
20.6  
14.4  
31.5  
25.8  
19.7  
13.4  
37.0  
31.5  
25.3  
19.1  
36.6  
31.0  
24.9  
18.6  
36.2  
30.6  
24.4  
18.1  
35.7  
30.1  
23.9  
17.7  
35.2  
29.6  
23.5  
17.2  
34.1*  
28.7  
22.5  
16.2  
39.9  
34.3  
28.1  
21.9  
39.4  
33.8  
27.7  
21.4  
38.7*  
33.4  
27.2  
21.0  
37.7*  
32.9  
26.7  
20.5  
36.8*  
32.4  
26.3  
20.0  
34.9*  
31.5  
25.3  
19.1  
85  
34.2  
29.3  
24.2  
3.37  
3.51  
3.64  
85  
37.1  
31.0  
24.7  
39.9  
33.8  
27.5  
3.29  
3.43  
3.57  
37.1* 3.39  
40.4* 41.3* 3.29  
90  
33.9  
28.9  
23.8  
3.53  
3.66  
3.81  
90  
36.7  
30.5  
24.2  
39.5  
33.3  
27.1  
3.42  
3.57  
3.71  
35.6* 36.5* 3.54  
39.6* 40.4* 3.42  
95  
31.3  
26.3  
21.2  
33.6  
28.6  
23.5  
3.68  
3.82  
3.97  
95  
36.2  
30.0  
23.8  
39.0  
32.9  
26.6  
3.56  
3.70  
3.85  
34.9* 35.7* 3.70  
38.6* 39.5* 3.55  
100  
105  
115  
30.9  
25.9  
20.7  
33.2  
28.2  
23.1  
3.84  
3.99  
4.14  
100  
105  
115  
35.7  
29.6  
23.3  
38.5  
32.4  
26.1  
3.69  
3.84  
4.00  
34.1* 34.9* 3.85  
37.7* 38.5* 3.69  
30.4  
25.4  
20.3  
32.8  
27.7  
22.6  
4.00  
4.15  
4.31  
35.2  
29.1  
22.8  
38.1  
31.9  
25.6  
3.83  
3.98  
4.14  
32.5* 33.3* 4.17  
35.7* 36.5* 3.96  
29.6  
24.6  
19.5  
31.9  
26.9  
21.8  
4.32  
4.48  
4.65  
34.3  
28.1  
21.9  
36.5* 4.11  
31.0  
24.7  
4.26  
4.42  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1150  
X0.98  
X0.99  
1500  
X1.02  
X1.01  
AIRFLOW  
SENS. CAP.  
1150  
X0.94  
1500  
X1.06  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1375  
X0.98  
X0.99  
1775  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
1375  
X0.93  
1775  
X1.05  
VALUES AT 95/80/67 RATING CONDITIONS  
VALUES AT 95/80/67 RATING CONDITIONS  
GROSS CAPACITY = 40800 BTUH  
AIRFLOW = 1325 CFM  
COMPRESSOR POWER = 3820 WATTS  
I.D. FAN POWER = 380 WATTS  
O.D. FAN POWER = 197 WATTS  
E.E.R. = 9.00 BTUH/WATT  
GROSS CAPACITY = 43900 BTUH  
AIRFLOW = 1570 CFM  
COMPRESSOR POWER = 3720 WATTS  
I.D. FAN POWER = 530 WATTS  
O.D. FAN POWER = 197 WATTS  
E.E.R. = 9.45 BTUH/WATT  
NOTE: RATED WITH 25 FEET OF 1-1/8 SUCTION AND 3/8 LIQUID LINE  
NOTE: RATED WITH 25 FEET OF 1-1/8 SUCTION AND 3/8 LIQUID LINE  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
16  
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Cooling  
Metric Units  
TTA040CD00A WITH TWE050CA50D  
TTA040CD00A WITH TWE040CA40C  
AT 2250 CMH  
AT 2717 CMH  
GROSS CAPACITY IN KILOWATTS  
GROSS CAPACITY IN KILOWATTS  
O.D.  
I.D. TOTAL  
D.B. W.B. CAP.  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
O.D.  
I.D. TOTAL  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
22.2  
10.0  
8.4  
6.6  
4.7  
9.9  
8.3  
6.4  
4.6  
9.8  
8.1  
6.3  
4.5  
9.6  
8.0  
6.2  
4.3  
9.5  
7.9  
6.0  
4.2  
9.2  
7.6  
5.8  
3.9  
23.3  
10.8  
9.2  
7.4  
5.6  
10.7  
9.1  
7.3  
5.4  
10.6  
9.0  
7.1  
5.3  
10.5  
8.8  
7.0  
5.2  
10.3  
8.7  
6.9  
5.0  
10.0*  
8.4  
24.4  
11.7  
10.0  
8.2  
6.4  
11.5  
9.9  
8.1  
6.3  
11.3*  
9.8  
8.0  
6.2  
11.0*  
9.6  
7.8  
6.0  
10.8*  
9.5  
7.7  
5.9  
10.2*  
9.2  
25.6  
12.1*  
10.9  
9.1  
26.7  
12.4*  
11.7  
9.9  
D.B. W.B. CAP.  
22.2  
8.6  
7.3  
5.9  
4.4  
8.6  
7.2  
5.8  
4.3  
8.5  
7.1  
5.7  
4.2  
8.4  
7.0  
5.5  
4.0  
8.2  
6.9  
5.4  
3.9  
8.0  
6.7  
5.2  
3.7  
23.3  
9.3  
8.0  
6.5  
5.0  
9.2  
7.9  
6.4  
5.0  
9.1  
7.8  
6.4  
4.9  
9.0  
7.7  
6.2  
4.7  
8.9  
7.6  
6.1  
4.6  
8.7  
7.3  
5.9  
4.4  
24.4  
10.0  
8.7  
7.2  
5.7  
9.9  
8.6  
7.1  
5.6  
9.8  
8.5  
7.0  
5.5  
9.7  
8.4  
6.9  
5.4  
25.6  
10.7  
9.3  
26.7  
11.0*  
10.0  
8.6  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
11.9  
12.7  
13.6  
14.5  
11.5  
12.4  
13.2  
14.1  
11.3  
12.0  
12.9  
13.7  
10.9  
11.7  
12.5  
13.3  
10.6  
11.3  
12.1  
12.9  
9.9  
3.16  
3.29  
3.43  
3.57  
3.29  
3.42  
3.57  
3.71  
3.42  
3.56  
3.70  
3.85  
3.55  
3.69  
3.84  
4.00  
3.69  
3.83  
3.98  
4.14  
3.96  
4.11  
4.26  
4.42  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
10.8  
11.6  
12.5  
13.4  
10.6  
11.4  
12.2  
13.1  
10.4  
11.1  
12.0  
12.8  
10.1  
10.8  
11.6  
12.4  
9.8  
10.5  
11.3  
12.1  
9.3  
9.9  
10.6  
11.4  
3.24  
3.37  
3.51  
3.64  
3.39  
3.53  
3.66  
3.81  
3.54  
3.68  
3.82  
3.97  
3.70  
3.84  
3.99  
4.14  
3.85  
4.00  
4.15  
4.31  
4.17  
4.32  
4.48  
4.65  
29.4  
32.2  
35.0  
37.8  
40.6  
46.1  
29.4  
32.2  
35.0  
37.8  
40.6  
46.1  
7.9  
6.4  
10.6  
9.3  
7.8  
6.3  
10.4*  
9.2  
7.7  
6.2  
10.2*  
9.1  
7.6  
6.1  
10.0*  
8.9  
7.4  
5.9  
9.5*  
8.7  
7.2  
5.7  
7.2  
8.1  
7.1  
11.8*  
10.8  
8.9  
12.1*  
11.6  
9.8  
10.9*  
9.9  
8.5  
7.0  
7.1  
7.9  
11.6*  
10.6  
8.8  
11.8*  
11.4  
9.6  
10.7*  
9.8  
8.4  
6.9  
7.0  
7.8  
11.3*  
10.5  
8.7  
11.6*  
11.3  
9.5  
10.5*  
9.7  
8.3  
6.8  
6.8  
7.6  
11.0*  
10.3  
8.5  
11.3*  
11.2  
9.3  
9.6*  
10.2*  
8.2  
6.8  
5.3  
9.3*  
8.0  
6.5  
5.0  
9.6  
8.1  
6.6  
9.8*  
9.3  
7.9  
6.4  
6.7  
7.5  
10.5*  
10.0  
8.2  
10.7*  
10.7  
9.1  
10.6  
11.3  
12.1  
6.6  
4.7  
7.4  
5.6  
6.4  
7.2  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1375  
X0.98  
X0.99  
1775  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
1375  
X0.93  
1775  
X1.05  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1150  
X0.98  
X0.99  
1500  
X1.02  
X1.01  
AIRFLOW  
SENS. CAP.  
1150  
X0.94  
1500  
X1.06  
VALUES AT 95/80/67 RATING CONDITIONS  
VALUES AT 95/80/67 RATING CONDITIONS  
GROSS CAPACITY = 12.0 KW  
AIRFLOW = 2253 CMS  
GROSS CAPACITY = 12.0 KW  
AIRFLOW = 2253 CMS  
COMPRESSOR POWER = 3720 WATTS  
I.D. FAN POWER = 380 WATTS  
O.D. FAN POWER = 197 WATTS  
EER = 9.00 BTU/WATT  
COMPRESSOR POWER = 3820 WATTS  
I.D. FAN POWER = 380 WATTS  
O.D. FAN POWER = 197 WATTS  
EER = 9.00 BTU/WATT  
NOTE: RATED WITH 7.62 METERS OF 1-1/8 IN. SUCTION AND 3/8 IN. LIQUID LINES  
NOTE: RATED WITH 7.62 METERS OF 1-1/8 IN. SUCTION AND 3/8 IN. LIQUID LINES  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
TWE5-PRC000-EN  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Cooling  
English Units  
TTA060CD WITH TWE050CA5C  
TTA050CD WITH TWE050CA5C  
AT 1800 CFM  
AT 1800 CFM  
GROSS CAPACITY IN BTU/H x 1000  
GROSS CAPACITY IN BTU/H x 1000  
O.D.  
D.B.  
I.D. GROSS  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
O.D.  
D.B.  
I.D. GROSS  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
W.B.  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
CAP.  
57.5  
61.6  
65.8  
70.2  
56.2  
60.2  
64.3  
68.6  
54.9  
58.8  
62.8  
66.9  
53.5  
57.3  
61.2  
65.2  
52.2  
55.8  
59.6  
63.5  
49.4  
52.8  
56.4  
60.0  
72  
74  
76  
78  
80  
W.B.  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
59  
63  
67  
71  
CAP.  
48.8  
52.1  
55.5  
59.0  
47.6  
50.8  
54.1  
57.5  
46.4  
49.5  
52.7  
56.0  
45.1  
48.1  
51.2  
54.4  
43.8  
46.7  
49.6  
52.7  
41.2  
43.8  
46.6  
49.4  
72  
74  
76  
78  
80  
43.6  
37.4  
30.6  
23.5  
43.0  
36.9  
30.0  
22.9  
42.5  
36.3  
29.4  
22.3  
41.9  
35.7  
28.8  
21.7  
41.3  
35.0  
28.2  
21.1  
40.1  
33.8  
26.9  
19.9  
46.8  
40.6  
33.7  
26.7  
46.2  
40.0  
33.1  
26.1  
45.6  
39.4  
32.5  
25.5  
45.0  
38.8  
31.9  
24.9  
44.4  
38.2  
31.3  
24.2  
43.2  
37.0  
30.1  
23.0  
49.9  
43.7  
36.8  
29.8  
49.3  
43.1  
36.2  
29.2  
48.7  
42.5  
35.7  
28.6  
48.1  
41.9  
35.0  
28.0  
47.5  
41.3  
34.4  
27.4  
46.3  
40.1  
33.2  
26.2  
53.0  
46.8  
40.0  
32.9  
52.5  
46.3  
39.4  
32.3  
51.9  
45.7  
38.8  
31.7  
51.3  
45.1  
38.2  
31.1  
50.7  
44.5  
37.6  
30.5  
56.2  
50.0  
43.1  
36.1  
55.6  
49.4  
42.5  
35.5  
4.71  
4.87  
5.04  
5.22  
4.90  
5.06  
5.23  
5.40  
39.4  
33.2  
26.3  
19.3  
38.9  
32.7  
25.8  
18.8  
38.4  
32.1  
25.3  
18.3  
37.8  
31.6  
24.7  
17.7  
37.3  
31.0  
24.2  
17.2  
36.2  
29.9  
23.0  
16.1  
42.5  
36.3  
29.4  
22.4  
42.0  
35.8  
28.9  
21.9  
41.5  
35.3  
28.4  
21.4  
40.9  
34.7  
27.8  
20.8  
40.4  
34.1  
27.3  
20.3  
39.3  
33.0  
26.1  
19.2  
45.6  
39.4  
32.5  
25.5  
45.1  
38.9  
32.0  
25.0  
44.6  
38.4  
31.5  
24.5  
44.0  
37.8  
30.9  
23.9  
43.5  
37.2  
30.4  
23.4  
41.6*  
36.1  
29.2  
22.3  
48.7  
42.5  
35.6  
28.6  
47.9*  
42.0  
35.1  
28.1  
49.9*  
45.6  
38.7  
31.7  
48.9*  
45.1  
38.2  
31.2  
3.62  
3.75  
3.89  
4.03  
3.77  
3.91  
4.05  
4.19  
3.93  
4.07  
4.21  
4.35  
4.09  
4.23  
4.37  
4.51  
4.25  
4.38  
4.52  
4.67  
4.57  
4.71  
4.84  
4.98  
85  
85  
90  
90  
55.0* 5.09  
47.0* 47.9*  
95  
48.8  
41.9  
34.9  
5.25  
5.42  
5.59  
95  
41.5  
34.6  
27.6  
44.6  
37.7  
30.7  
54.0* 5.31  
45.9* 46.8*  
100  
105  
115  
48.2  
41.3  
34.3  
5.47  
5.63  
5.79  
100  
105  
115  
40.9  
34.0  
27.0  
44.0  
37.1  
30.1  
52.9* 5.53  
44.8* 45.7*  
47.6  
40.7  
33.7  
5.68  
5.84  
6.00  
40.3  
33.5  
26.5  
43.4  
36.6  
29.6  
49.4* 50.6* 5.98  
42.5* 43.4*  
43.2  
36.3  
29.3  
46.4  
39.5  
32.4  
6.12  
6.26  
6.41  
39.2  
32.3  
25.4  
42.3  
35.4  
28.5  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1525  
X0.98  
X0.98  
1975  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
1525  
X0.94  
1975  
X1.04  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1525  
X0.98  
X0.99  
1975  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
1525  
X0.93  
1975  
X1.04  
VALUES AT 95/80/67 RATING CONDITIONS  
VALUES AT 95/80/67 RATING CONDITIONS  
GROSS CAPACITY = 62500 BTUH  
AIRFLOW = 1750 CFM  
GROSS CAPACITY = 52500 BTUH  
AIRFLOW = 1750 CFM  
COMPRESSOR POWER = 5402 WATTS  
I.D. FAN POWER = 730 WATTS  
O.D. FAN POWER = 386 WATTS  
E.E.R. = 9.15 BTUH/WATT  
COMPRESSOR POWER = 4202 WATTS  
I.D. FAN POWER = 730 WATTS  
O.D. FAN POWER = 202 WATTS  
E.E.R. = 9.75 BTUH/WATT  
NOTE: RATED WITH 25 FEET OF 1-1/8 SUCTION AND 3/8 LIQUID LINE  
NOTE: RATED WITH 25 FEET OF 1-1/8 SUCTION AND 3/8 LIQUID LINE  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
18  
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance Data  
Cooling  
Metric Units  
TTA060CD WITH TWE050CA5C  
TTA050CD WITH TWE050CA5C  
AT 3056 CMH  
AT 3056 CMH  
GROSS CAPACITY IN KILOWATTS  
GROSS CAPACITY IN KILOWATTS  
O.D.  
I.D. TOTAL  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
O.D.  
I.D. TOTAL  
SENS. CAP. AT ENTERING D.B. TEMP.  
COMPR.  
KW  
D.B. W.B. CAP.  
22.2  
12.8  
11.0  
9.0  
23.3  
13.7  
11.9  
9.9  
24.4  
14.6  
12.8  
10.8  
8.7  
25.6  
15.5  
13.7  
11.7  
9.6  
26.7  
16.5  
14.7  
12.6  
10.6  
16.3  
14.5  
12.5  
10.4  
16.1*  
14.3  
12.3  
10.2  
15.8*  
14.1  
12.1  
10.0  
15.5*  
13.9  
11.9  
9.9  
D.B. W.B. CAP.  
22.2  
11.5  
9.7  
23.3  
12.5  
10.6  
8.6  
24.4  
13.4  
11.5  
9.5  
25.6  
14.3  
12.5  
10.4  
8.4  
26.7  
14.6*  
13.4  
11.3  
9.3  
14.3*  
13.2  
11.2  
9.1  
14.0*  
13.1  
11.0  
9.0  
13.7*  
12.9  
10.9  
8.8  
13.4*  
12.7  
10.7  
8.7  
12.7*  
12.4  
10.4  
8.4  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
16.8  
18.0  
19.3  
20.6  
16.5  
17.6  
18.8  
20.1  
16.1  
17.2  
18.4  
19.6  
15.7  
16.8  
17.9  
19.1  
15.3  
16.3  
17.5  
18.6  
14.5  
15.5  
16.5  
17.6  
4.71  
4.87  
5.04  
5.22  
4.90  
5.06  
5.23  
5.40  
5.09  
5.25  
5.42  
5.59  
5.31  
5.47  
5.63  
5.79  
5.53  
5.68  
5.84  
6.00  
5.98  
6.12  
6.26  
6.41  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
15.0  
17.2  
19.4  
21.7  
14.3  
15.3  
16.3  
17.3  
13.9  
14.9  
15.9  
16.8  
13.6  
14.5  
15.4  
16.4  
13.2  
14.1  
15.0  
15.9  
12.8  
13.7  
14.5  
15.4  
12.1  
12.8  
13.7  
14.5  
3.62  
3.75  
3.89  
4.03  
3.77  
3.91  
4.05  
4.19  
3.93  
4.07  
4.21  
4.35  
4.09  
4.23  
4.37  
4.51  
4.25  
4.38  
4.52  
4.67  
4.57  
4.71  
4.84  
4.98  
29.4  
32.2  
35.0  
37.8  
40.6  
46.1  
29.4  
32.2  
35.0  
37.8  
40.6  
46.1  
7.7  
5.7  
6.9  
7.8  
6.6  
7.5  
12.6  
10.8  
8.8  
13.5  
11.7  
9.7  
14.4  
12.6  
10.6  
8.6  
15.4  
13.6  
11.5  
9.5  
11.4  
9.6  
7.6  
12.3  
10.5  
8.5  
13.2  
11.4  
9.4  
14.0*  
12.3  
10.3  
8.2  
6.7  
7.6  
5.5  
6.4  
7.3  
12.5  
10.6  
8.6  
13.4  
11.5  
9.5  
14.3  
12.5  
10.5  
8.4  
15.2  
13.4  
11.4  
9.3  
11.3  
12.2  
10.3  
8.3  
13.1  
11.3  
9.2  
13.8*  
12.2  
10.1  
8.1  
9.4  
7.4  
5.4  
6.5  
7.5  
6.3  
7.2  
12.3  
10.5  
8.4  
13.2  
11.4  
9.3  
14.1  
12.3  
10.3  
8.2  
15.0  
13.2  
11.2  
9.1  
11.1  
12.0  
10.2  
8.1  
12.9  
11.1  
9.1  
13.4*  
12.0  
10.0  
7.9  
9.3  
7.2  
5.2  
6.4  
7.3  
6.1  
7.0  
12.1  
10.3  
8.3  
13.0  
11.2  
9.2  
13.9  
12.1  
10.1  
8.0  
14.9  
13.0  
11.0  
8.9  
10.9  
9.1  
7.1  
5.0  
11.8  
10.0  
8.0  
12.7  
10.9  
8.9  
13.1*  
11.8  
9.8  
6.2  
7.1  
5.9  
6.9  
7.8  
11.7  
12.7  
10.8  
8.8  
13.6  
11.7  
9.7  
14.5*  
12.7  
10.6  
8.6  
14.8*  
13.6  
11.6  
9.5  
10.6  
8.8  
6.7  
11.5  
9.7  
7.6  
12.2*  
10.6  
8.6  
12.5*  
11.5  
9.5  
9.9  
7.9  
5.8  
6.7  
7.7  
4.7  
5.6  
6.5  
7.4  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
CORRECTION FACTORS - OTHER AIRFLOWS (MULTIPLY OR ADD AS INDICATED)  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1525  
X0.98  
X0.98  
1975  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
1525  
X0.94  
1975  
X1.04  
AIRFLOW  
TOTAL CAP.  
COMPR. KW  
1525  
X0.98  
X0.99  
1975  
X1.01  
X1.01  
AIRFLOW  
SENS. CAP.  
1525  
X0.93  
1975  
X1.04  
VALUES AT 95/80/67 RATING CONDITIONS  
VALUES AT 95/80/67 RATING CONDITIONS  
GROSS CAPACITY = 14.6 KW  
AIRFLOW = 3056 CMH  
GROSS CAPACITY = 14.6 KW  
AIRFLOW = 3056 CMH  
COMPRESSOR POWER = 4202 WATTS  
I.D. FAN POWER = 730 WATTS  
O.D. FAN POWER = 202 WATTS  
EER = 9.75 BTU/WATT  
COMPRESSOR POWER = 4202 WATTS  
I.D. FAN POWER = 730 WATTS  
O.D. FAN POWER = 202 WATTS  
EER = 9.75 BTU/WATT  
NOTE: RATED WITH 7.62 METERS OF 1-1/8 IN. SUCTION AND 3/8 IN. LIQUID LINES  
NOTE: RATED WITH 7.62 METERS OF 1-1/8 IN. SUCTION AND 3/8 IN. LIQUID LINES  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
* DRY COIL CONDITION (TOTAL CAPACITY = SENSIBLE CAPACITY)  
TOTAL CAPACITY AND COMP. KW ARE VALID ONLY FOR WET COIL  
ALL TEMPERATURES IN DEGREES F  
TWE5-PRC000-EN  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance  
Data  
Evaporator Fan Performance  
BLOWER PERFORMANCE — TWE030CA40B — WET COIL  
EXTERNAL STATIC PRESSURE INCHES OF WATER (PASCALS)  
UPFLOW & DOWNFLOW (See Notes)  
HORIZONTAL; NO FILTER (See Notes)  
220 VOLTS  
MED  
220 VOLTS  
MED  
CFM  
600  
650  
700  
750  
800  
850  
900  
950  
1000  
1050  
1100  
1150  
1200  
CMH  
Hl  
LO  
Hl  
LO  
1018.8  
1103.7  
1188.6  
1273.5  
1358.4  
1443.3  
1528.2  
1613.1  
1698.0  
1782.9  
1867.8  
1952.7  
2037.6  
0.72 (179.4)  
0.62 (154.4)  
0.51 (127.0)  
0.40  
0.29  
0.18  
0.06  
0.71  
0.61  
0.50  
0.39  
0.28  
0.17  
0.08  
(176.9)  
(152.0)  
(124.6)  
(97.1)  
(69.7)  
(42.3)  
(19.9)  
0.86 (214.2)  
0.75 (186.8)  
0.65 (161.9)  
0.54 (134.5)  
0.43 (107.1)  
0.84 (209.2)  
0.72 (179.4)  
0.62 (154.4)  
0.51 (127.0)  
(99.6)  
(72.2)  
(44.8)  
(14.9)  
0.89 (221.7)  
0.81 (201.8)  
0.72 (179.4)  
0.63 (156.9)  
0.53 (132.0)  
0.42 (104.6)  
0.87 (216.7)  
0.79 (196.8)  
0.69 (171.9)  
0.61 (152.0)  
0.51 (127.0)  
0.40  
0.31  
0.22  
0.10  
0.40  
0.30  
0.17  
0.02  
(99.6)  
(74.7)  
(42.3)  
(5.0)  
0.32  
0.21  
0.10  
(79.7)  
(52.3)  
(24.9)  
(99.6)  
(77.2)  
(54.8)  
(24.9)  
0.31  
0.20  
0.08  
(77.2)  
(49.8)  
(19.9)  
NOTES:  
Vertical: With filter, no horizontal drip tray. Subtract 0.06" W.G. for downflow.  
Horizontal: As shipped, but without filter. Subtract 0.05" W.G. for horizontal left.  
BLOWER PERFORMANCE — TWE040CA40C — WET COIL  
EXTERNAL STATIC PRESSURE INCHES OF WATER (PASCALS)  
UPFLOW & DOWNFLOW (See Notes)  
HORIZONTAL; NO FILTER (See Notes)  
220 VOLTS  
MED  
220 VOLTS  
MED  
CFM  
700  
750  
800  
850  
900  
950  
1000  
1050  
1100  
1150  
1200  
1250  
1300  
1350  
1400  
1450  
1500  
CMH  
Hl  
LO  
Hl  
LO  
1188.6  
1273.5  
1358.4  
1443.3  
1528.2  
1613.1  
1698.0  
1782.9  
1867.8  
1952.7  
2037.6  
2122.5  
2207.4  
2292.3  
2377.2  
2462.1  
2547.0  
0.58 (144.5)  
0.61 (152.0)  
0.58 (144.5)  
0.54 (134.5)  
0.51 (127.0)  
0.47 (117.1)  
0.43 (107.1)  
0.55 (137.0)  
0.52 (129.5)  
0.48 (119.6)  
0.44 (109.6)  
0.61 (152.0)  
0.57 (142.0)  
0.53 (132.0)  
0.49 (122.1)  
0.45 (112.1)  
0.58  
0.52  
0.49  
0.45  
0.40  
0.35  
0.30  
0.22  
0.17  
0.10  
(144.5)  
(129.5)  
(122.1)  
(112.1)  
(99.6)  
(87.2)  
(74.7)  
(54.8)  
(42.3)  
(24.9)  
0.40  
0.34  
0.28  
0.22  
0.15  
0.08  
0.00  
0.26  
(99.6)  
(84.7)  
(69.7)  
(54.8)  
(37.4)  
(19.9)  
(0.0)  
0.57 (142.0)  
0.50 (124.6)  
0.45 (112.1)  
0.53 (132.0)  
0.48 (119.6)  
0.43 (107.1)  
0.40  
0.36  
0.31  
0.26  
0.21  
0.17  
0.11  
0.06  
0.01  
0.00  
(99.6)  
(89.7)  
(77.2)  
(64.8)  
(52.3)  
(42.3)  
(27.4)  
(14.9)  
(2.5)  
0.38  
0.34  
0.29  
0.24  
0.18  
0.13  
0.07  
0.01  
(94.7)  
(84.7)  
(72.2)  
(59.8)  
(44.8)  
(32.4)  
(17.4)  
(2.5)  
0.40  
0.37  
0.32  
0.28  
0.01  
0.18  
0.12  
0.08  
0.02  
(99.6)  
(92.2)  
(79.7)  
(69.7)  
(2.5)  
(44.8)  
(29.9)  
(19.9)  
(5.0)  
0.39  
0.35  
0.31  
0.22  
0.21  
0.15  
0.11  
0.05  
(97.1)  
(87.2)  
(77.2)  
(54.8)  
(52.3)  
(37.4)  
(27.4)  
(12.5)  
(64.8)  
NOTES:  
Vertical: With filter, no horizontal drip tray. Small apex baffle. Subtract 0.06" W.G. for downflow.  
Horizontal: As shipped, but without filter. Subtract 0.05" W.G. for horizontal left.  
20  
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance  
Data  
BLOWER PERFORMANCE — TWE050CA50D — WET COIL  
EXTERNAL STATIC PRESSURE INCHES OF WATER (PASCALS)  
UPFLOW & DOWNFLOW (See Notes)  
HORIZONTAL; NO FILTER (See Notes)  
220 VOLTS  
MED  
220 VOLTS  
MED  
CFM  
900  
CMH  
Hl  
LO  
Hl  
LO  
1528.2  
1613.1  
1698.0  
1782.9  
1867.8  
1952.7  
2037.6  
2122.5  
2207.4  
2292.3  
2377.2  
2462.1  
2547.0  
2631.9  
2716.8  
2801.7  
2886.6  
2971.5  
3056.4  
3141.3  
3226.2  
3311.1  
950  
0.63 (156.9)  
0.61 (152.0)  
0.58 (144.5)  
0.54 (134.5)  
0.50 (124.6)  
0.45 (112.1)  
1000  
1050  
1100  
1150  
1200  
1250  
1300  
1350  
1400  
1450  
1500  
1550  
1600  
1650  
1700  
1750  
1800  
1850  
1900  
1950  
0.62  
0.60  
0.57  
0.53  
0.49  
0.44  
0.38  
0.32  
0.25  
0.18  
0.11  
0.00  
(154.4)  
(149.5)  
(142.0)  
(132.0)  
(122.1)  
(109.6)  
(94.7)  
(79.7)  
(62.3)  
(44.8)  
(27.4)  
(0.0)  
0.61 (152.0)  
0.57 (142.0)  
0.53 (132.0)  
0.49 (122.1)  
0.45 (112.1)  
0.39  
0.33  
0.26  
0.18  
0.10  
0.01  
(97.1)  
(82.2)  
(64.8)  
(44.8)  
(24.9)  
(2.5)  
0.64 (159.4)  
0.59 (147.0)  
0.56 (139.5)  
0.52 (129.5)  
0.48 (119.6)  
0.44 (109.6)  
0.40 (99.6)  
0.35 (87.2)  
0.31 (77.2)  
0.26 (64.8)  
0.21 (52.3)  
0.16 (39.9)  
0.11 (27.4)  
0.05 (12.5)  
0.62 (154.4)  
0.59 (147.0)  
0.56 (139.5)  
0.52 (129.5)  
0.49 (122.1)  
0.47 (117.1)  
0.45 (112.1)  
0.41 (102.1)  
0.61 (152.0)  
0.58 (144.5)  
0.55 (137.0)  
0.52 (129.5)  
0.48 (119.6)  
0.44 (109.6)  
0.40  
0.35  
0.30  
0.25  
0.20  
0.14  
0.08  
0.02  
(99.6)  
(87.2)  
(74.7)  
(62.3)  
(49.8)  
(34.9)  
(19.9)  
(5.0)  
0.40  
0.35  
0.28  
0.20  
0.13  
0.07  
0.01  
(99.6)  
(87.2)  
(69.7)  
(49.8)  
(32.4)  
(17.4)  
(2.5)  
0.36  
0.30  
0.24  
0.17  
0.10  
0.02  
(89.7)  
(74.7)  
(59.8)  
(42.3)  
(24.9)  
(5.0)  
NOTES:  
Vertical: With filter, no horizontal drip tray. Small apex baffle  
Subtract 0.06" W.G. for downflow.  
Horizontal: As shipped, but without filter. Subtract 0.05" W.G for horizontal left.  
TWE5-PRC000-EN  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Performance  
Data  
Air Pressure Drop (Inches) - Electric Heaters  
PRESSURE DROP FOR ELECTRIC HEATERS  
IN AIR HANDLER MODELS  
NUMBER OF RACKS  
1
2
3
4
5
AIRFLOW AIRFLOW  
AIR PRESSURE DROP  
CFM  
600  
CMH  
IN. W.G. (PASCALS)  
1018.8  
1188.6  
1358.4  
1528.2  
1698.0  
1867.8  
2037.6  
2207.4  
2377.2  
2547.0  
2716.8  
2886.6  
3056.4  
3226.2  
3396.0  
0.01  
0.01  
0.02  
0.03  
0.04  
0.04  
0.05  
0.06  
0.07  
0.08  
0.09  
0.10  
0.11  
0.13  
0.14  
(2.5)  
(2.5)  
0.02  
0.02  
0.03  
0.03  
0.04  
0.05  
0.06  
0.07  
0.08  
0.09  
0.10  
0.11  
0.13  
0.15  
0.17  
(5.0)  
(5.0)  
0.02  
0.02  
0.03  
0.04  
0.05  
0.06  
0.07  
0.08  
0.10  
0.11  
0.12  
0.14  
0.16  
0.18  
0.20  
(5.0)  
(5.0)  
700  
800  
(5.0)  
(7.5)  
(7.5)  
0.04  
0.05  
0.06  
0.07  
0.08  
0.09  
0.11  
0.13  
0.15  
0.17  
0.19  
0.21  
0.23  
(10.0)  
(12.5)  
(14.9)  
(17.4)  
(19.9)  
(22.4)  
(27.4)  
(32.4)  
(37.4)  
(42.3)  
(47.3)  
(52.3)  
(57.3)  
900  
(7.5)  
(7.5)  
(10.0)  
(12.5)  
(14.9)  
(17.4)  
(19.9)  
(24.9)  
(27.4)  
(29.9)  
(34.9)  
(39.9)  
(44.8)  
(49.8)  
1000  
1100  
1200  
1300  
1400  
1500  
1600  
1700  
1800  
1900  
2000  
(10.0)  
(10.0)  
(12.5)  
(14.9)  
(17.4)  
(19.9)  
(22.4)  
(24.9)  
(27.4)  
(32.4)  
(34.9)  
(10.0)  
(12.5)  
(14.9)  
(17.4)  
(19.9)  
(22.4)  
(24.9)  
(27.4)  
(32.4)  
(37.4)  
(42.3)  
0.08  
0.09  
0.11  
0.13  
0.15  
0.17  
0.19  
0.21  
0.23  
0.26  
(19.9)  
(22.4)  
(27.4)  
(32.4)  
(37.4)  
(42.3)  
(47.3)  
(52.3)  
(57.3)  
(64.8)  
NOTES:  
1. See Product Data or Air Handler nameplate for approved combinations of Air Handlers and Heaters.  
2. Heater model numbers may have additional suffix digits.  
HEATER RACKS  
HEATER  
NO. OF  
MODEL NO.  
BAY96X1405  
BAY96X1406  
BAY96X1408  
BAY96X1410  
BAY96X1411  
BAY96X1415  
BAY96X1419  
BAY96X1421  
BAY96X1426  
BAY96X3411  
BAY96X3415  
RACKS  
1
2
2
2
3
3
4
4
5
3
3
22  
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Supplementary  
Heaters  
THESE AIR HANDLERS ARE CONVERTIBLE AND MOTOR SPEED TAPS VARY BY THE UNIT ORIENTATION.  
TWE030C-HEATER MODEL NUMBER BAY96X  
Unit  
1405  
1406  
1408,F  
1410,F 1410A  
1411  
1411A  
1415  
1419  
1421  
3411  
3415  
Position  
Vertical  
Upflow  
Vertical  
Application  
A/C or Elec. Furnace  
Heat Pump  
A/C or Elec. Furnace  
4.0 KW 4.8 KW  
6.4 KW  
8.0 KW 8.8 KW 8.8 KW  
8.8 KW 12.8 KW 16.0 KW 17.6 KW 8.8 KW 12.8 KW  
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
M
L
H
L
M
L
H
L
M
L
H
L
M
L
H
L
L
L
L
L
L
L
L
L
L
L
H
L
L
L
L
Downflow Heat Pump  
Horizontal A/C or Elec. Furnace  
Left  
Horizontal A/C or Elec. Furnace  
Right Heat Pump  
Heat Pump  
(L) Low, (M) Medium, (H) High indicate minimum heating speed setting for blower/motor operation. 1414 and 1426 not approved for this model.  
TWE040C-HEATER MODEL NUMBER BAY96X  
Unit  
1405  
1406  
1408,F  
1410,F 1410A  
1411  
1411A  
1415  
1419  
1421  
3411  
3415  
Position  
Vertical  
Upflow  
Vertical  
Application  
A/C or Elec. Furnace  
Heat Pump  
4.0 KW 4.8 KW  
6.4 KW  
8.0 KW 8.8 KW 8.8 KW  
8.8 KW 12.8 KW 16.0 KW 17.6 KW 8.8 KW 12.8 KW  
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
M
L
L
L
L
L
L
L
M
L
L
H
L
L
H
L
L
H
L
L
M
L
L
M
L
A/C or Elec. Furnace  
Downflow Heat Pump  
Horizontal A/C or Elec. Furnace  
Left  
Horizontal A/C or Elec. Furnace  
Right Heat Pump  
L
L
H
L
H
L
H
L
L
L
L
L
Heat Pump  
L
L
H
L
H
L
H
L
L
L
L
L
L
H
H
H
L
L
(L) Low, (M) Medium, (H) High indicate minimum heating speed setting for blower/motor operation. 1414 not approved for this model.  
TWE050C-HEATER MODEL NUMBER BAY96X  
Unit  
1405  
1406  
1408,F  
1410,F  
1410A  
1415  
1419  
1421  
1426  
3415  
Position  
Vertical  
Upflow  
Vertical  
Application  
A/C or Elec. Furnace  
Heat Pump  
4.0 KW  
L
L
L
4.8 KW  
L
L
L
6.4 KW  
8.0 KW  
8.8 KW  
12.8 KW  
16.0 KW  
17.6 KW 21.6 KW 12.8 KW  
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
L
M
L
H
L
H
L
M
L
M
L
L
H
L
L
L
L
L
L
L
L
L
A/C or Elec. Furnace  
Downflow Heat Pump  
Horizontal A/C or Elec. Furnace  
Left  
Horizontal A/C or Elec. Furnace  
Right Heat Pump  
H
L
H
L
Heat Pump  
H
L
M
H
L
H
L
L
(L) Low, (M) Medium, (H) High indicate minimum heating speed setting for blower/motor operation. 14141,A & 1414 not approved for this model.  
TWE5-PRC000-EN  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System  
Wiring  
Diagram  
24  
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensional  
Data  
TWE030-050C Outline Drawing  
All dimensions are in inches (mm)  
FLOW  
MINIMUM UNIT CLEARANCE SALE  
MODEL NO.  
TWE030CA4  
A
43.00  
B
15.57  
C
21.50  
D
19.50  
E
20.28  
F
CONTROL  
TO COMBUSTIBLE  
MATERIAL (REQUIRED)  
SERVICE CLEARANCE  
(RECOMMENDED)  
21.63  
FCCV  
FCCV  
TXV  
(1092.2) (395.5) (761.1) (495.3) (515.1) (549.4)  
51.75 24.32 23.50 21.50 22.28 23.63  
(1134.5) (617.7) (596.9) (761.1) (565.9) (600.2)  
57.90 30.47 23.50 21.50 22.28 23.63  
(1470.7) (773.9) (596.9) (761.1) (565.9) (600.2)  
SIDES  
FRONT  
BACK  
0
0
0
0
1
(0)  
2
21  
0
(50.8)  
(533.4)  
(0)  
TWE040CA4  
TWE050CA5  
(0)  
(0)  
(0)  
(25.4)  
INLET DUCT  
OUTLET DUCT  
1
(25.4)  
TWE5-PRC000-EN  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensional  
Data  
1 INCH = (25.40 MILLIMETERS)  
TTB524-536CA Outline Drawing  
All dimensions are in inches (mm)  
CABINET  
SIZE  
PT. NO.  
A
B
C
D
E
1
3
TTB524CA  
25A  
251/2  
11/16  
/2  
/4  
5/16  
(8)  
5/16  
(8)  
(648) 14 UNS-2A 20UNF-2A  
(19  
1
3
TTB530CA/  
TTB536CA  
25C  
321/2  
11/16  
/2  
/
4
(826) 14 UNS-2A 20UNF-2A  
(19)  
FLARE NUT TORQUE  
TORQUE FT-LBS (NEWTON METERS)  
APPLIED TUBE SIZE  
MINIMUM  
8 (11.0)  
MAXIMUM  
10 (14.0)  
15 (20.0)  
25 (34.0)  
35 (47.0)  
55 (75.0)  
60 (81.0)  
1
/4  
(6.35)  
5/16 (7.94)  
10 (14.0)  
15 (20.0)  
25 (34.0)  
40 (54.0)  
50 (68.0)  
3
/
8
(9.52)  
1
/
2
(12.70)  
(15.88)  
(19.05)  
5
3
/
8
/
4
BACK-UP  
HEX SIZE  
1 1/16-14 = 1 1/16  
(27)  
1
/
2-20 = 1/2  
(13)  
SERVICE PANEL  
ELECTRICAL AND REFRIGERANT  
COMPONENTS CLEARANCES  
PER PREVAILING CODES  
TOP DISCHARGE AREA SHOULD BE  
UNRESTRICTED FOR AT LEAST 1524  
(5 FEET) ABOVE UNIT. UNIT SHOULD BE  
PLACED SO ROOF RUN-OFF WATER  
DOES NOT POUR DIRECTLY ON UNIT  
AND SHOULD BE AT LEAST 305 (12”)  
FROM WALL AND ALL SURROUNDING  
SHRUBBERY ON TWO SIDES. OTHER  
TWO SIDES UNRESTRICTED.  
“CSAE MALE FLARE FOR “E” O.D. TUBE SIZE  
CONNECTION WITH 1/4” SAE FLARE  
PRESSURE TAP FITTING.  
“BSAE MALE FLARE FOR “D” O.D. TUBE SIZE  
CONNECTION WITH 1/4” SAE FLARE  
PRESSURE TAP FITTING.  
26  
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensional  
Data  
TTA030-060C Outline Drawing  
All dimensions are in inches (mm)  
TOP DISCHARGE AREA SHOULD BE  
UNRESTRICTED FOR AT LEAST FIVE (5)  
FEET ABOVE UNIT. UNIT SHOULD BE  
PLACED SO ROOF RUN-OFF WATER  
DOES NOT POUR DIRECTLY ON UNIT,  
AND SHOULD BE AT LEAST 12” (305)  
FROM WALL AND ALL SURROUNDING  
SHRUBBERY ON TWO SIDES. OTHER  
TWO SIDES UNRESTRICTED.  
FIG. 1  
MODEL  
TTA030C  
Figure  
1
A
B
C
D
/8  
E
/8  
7
3
24 3/8  
28 1/4  
24 5/8  
(619.1) (714.4)  
32 3/4 28 1/4  
(831.9) (714.4)  
40 5/8 32 7/8  
(1031.9) (835.0)  
44 3/4 38 7/8  
(1136.7) (987.4)  
(625.5) (22.2) (9.53)  
3
TTA040C  
TTA050C  
TTA060C  
1
2
2
24 5/8  
1 1/8  
/
8
(625.5) (28.6) (9.53)  
3
28 3/4  
1 1/8  
/
8
(730.3) (28.6) (9.53)  
34 3/4  
1 1/8  
/
8
3
FIG. 2  
(882.7) (28.6) (9.53)  
TWE5-PRC000-EN  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensional  
Data  
TWE030 Through 050 Convertibility  
Six (6) Way Convertibility  
OneUnit-4Applications  
EasyConversiontoOppositeSideAccess  
28  
TWE5-PRC000-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mechanical  
Specifications  
General  
Coil  
Blower coil units shall be completely  
factory assembled including coil,  
condensate drain pan, fan, motor, filters  
and controls in an insulated casing that  
can be applied in horizontal or vertical  
configuration.  
Aluminum fin surface shall be  
mechanically bonded to 3/8-inch OD  
copper tubing. Coils shall be factory  
pressure and leak tested.  
Fan  
Forward curved, dynamically and  
statically balanced with three-speed  
direct drive shall be standard, fan motor  
bearing shall be permanently lubricated.  
This new line of TWE-C air handlers  
provides exclusive compact size  
combined with simple four-way  
convertibility in three sizes. The unit  
ships in the right hand horizontal  
configuration and converts to vertical  
upflow just by standing the unit on end.  
No tools required. Simple coil rotation  
provides downflow and horizontal left  
applications.  
Controls  
Fan contactor, and plug-in module for  
accessory electric heat control shall be  
included. TWE models shall also include  
check valves.  
Filters  
Filters shall be included as standard.  
The four-way convertibility provides you  
inventory benefits and service/  
Accessories  
installation flexibility. The simple  
conversion provides opposite side  
access for installation and service.  
Electric Heaters — Shall be available in a  
wide range of capacities and voltages  
with various staging options and plug in  
control wiring. Heaters shall fit inside  
internal compartment.  
Casing  
Units shall have rugged sheet metal and  
steel frame construction and shall be  
painted with an enamel finish. Casing  
shall be insulated and knockouts shall be  
provided for electrical power and control  
wiring.  
Refrigerant Circuits  
The TWE units shall have a single  
refrigerant circuit. TWE03-040C  
refrigerant circuit shall be controlled by a  
flow control check valve (FCCV). The  
TWE050C refrigerant circuit shall be  
controlled by a factory-installed thermal  
expansion valve.  
TWE5-PRC000-EN  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
File No.  
TWE5-PRC000-EN 4/99  
TWE5-PRC000-EN 2/98  
Supersedes  
TheTraneCompany  
InternationalUnitaryProductsGroup  
3600PammelCreekRoad  
La Crosse, WI 54601-7599  
Stocking Location La Crosse  
SinceTheTraneCompanyhasapolicyofcontinuousproductimprovement, itreservestherighttochangedesign  
andspecificationwithoutnotice.  
AnAmericanStandardCompany  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Telenetics Network Router DSP9612FP User Manual
Thermador Microwave Oven MET27E User Manual
Toshiba Projector tdpT90 User Manual
Tripp Lite Surge Protector SK120USB User Manual
Tripp Lite Surge Protector TLM812GF User Manual
Troy Bilt Blower TB120BV User Manual
Troy Bilt Lawn Mower 52057 User Manual
Uniden Cordless Telephone TRU9385 User Manual
Velodyne Acoustics Speaker VRP 1000 User Manual
Viking Refrigerator F21169 EN User Manual