Trane Oven fin prc003en User Manual

Electric Wall Fin  
Model EWFB — Electric Wall Fin  
October 2001  
FIN-PRC003-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Features and Benefits  
Dimensional Data  
2
4
Wiring Diagrams  
9
Mechanical Specifications  
14  
DBCT — Bottom Inlet (Top Discharge)  
DBCF — Front Inlet (Top Discharge)  
5" Deep x 7" High — 10-Gauge Extruded  
Aluminum Front and Grille  
RDBT-PD Architectural Draft Barrier  
6" Deep x 5" High — 12-Gauge Extruded  
Pedestal Mount  
ASHDB — 8 through 20  
5 1/2" Deep x 8" thru 20" High  
Front Cover 16-Gauge Steel with  
12-Gauge Extruded Aluminum Grille  
FIN-PRC003-EN  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensional  
Data  
Model EWFB  
Type DBF Wall Mounted (Bottom Louver)  
15' (4.57 M) Length DBF and DBT Only Wall Mounted  
Architectural Pedestal Heaters  
Series DBT and DBF  
100-250 Watt Per Foot  
4
FIN-PRC003-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensional  
Data  
Model EWFB  
Type CB Wall Mounted  
Typical Installation  
Pedestal Heaters – Series CB  
250 Watts Per Foot – Element Pedestals  
FIN-PRC003-EN  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensional  
Data  
Model EWFB  
Type DBCT and DBCF (Bottom Louver) Wall Mounted  
NOTE:  
Front covers available as standard through 15’.  
Backplate available as option through 15’.  
Typical Installation  
Architectural Pedestal Heaters  
Series DBCF, DBCT  
6
FIN-PRC003-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensional  
Data  
Model EWFB  
Model RDBT-PD Pedestal Floor Mounted  
Unit Length  
Dimension “A”  
Feet  
Dimension “A”  
Meters  
0.61  
2 Ft.  
3 Ft.  
0.91  
4 Ft.  
1.22  
5 Ft.  
1.52  
6 Ft.  
1.83  
7 Ft.  
2.13  
8 Ft.  
2.44  
9 Ft.  
2.74  
10 Ft.  
3.05  
FIN-PRC003-EN  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensional  
Data  
Model EWFB  
Type ASHDB-8 thru 20 Wall Mounted  
Knockouts and Mounting Holes  
Typical Installation  
*Architectural Pedestal Heaters –  
Series ASHDB-8 8High  
100-500 Watts Per Foot  
*8" high ASHDB unit is the only size that can be mounted on pedestals.  
8
FIN-PRC003-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring  
Diagrams  
Model EWFB  
Field Wiring With Integral Controls  
When heaters are furnished with  
controls, make certain that the heater or  
heaters do not exceed the lowest  
amperage rating of the controls  
furnished. For example, if a thermostat  
and disconnect are furnished, the  
thermostat is rated at 25 amps 240 and  
277, the disconnect is rated 20 amps 240  
and 277. Therefore, the combination of  
heaters should not exceed 20 amps at  
277 or 240.  
Controls  
Description Single Pole  
Catalog Number DBF-ITS, DBT-ITS,  
CDF-ITS, CDT-ITS  
Rated 25 amps at 120-277 VAC. 50-110°F  
temperature range. Tamperproof and  
adjustable through discharge louver.  
Integral thermostats: wire entry from  
either end.  
Disconnect switch: right hand wire  
entry.  
Thermostat and disconnect: right hand  
wire entry.  
Relays: right hand wire entry – control  
section.  
Description Double Pole Thermostat  
Catalog Number DBF-ITD, DBT-ITD,  
CDF-ITD, CDT-ITD  
Thermostat – disconnect and relay:  
right hand wire entry – control section.  
Rated 25 amps at 120-277 VAC. 50-110°F  
temperature range. Tamperproof and  
adjustable through discharge louver.  
Description Disconnect Switch  
Catalog Number DBF-IDS, DBT-IDS,  
CDF-IDS, CDT-IDS  
Double pole rated 20 amps at 120-277  
VAC.  
Wiring Diagrams  
Wiring Diagrams Control Section  
FIN-PRC003-EN  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring  
Diagrams  
Model EWFB  
Field Wiring With Integral Controls  
When heaters are furnished with  
controls, make certain that the heater or  
heaters do not exceed the lowest  
amperage rating of the controls  
furnished. For example, if a thermostat  
and disconnect are furnished, the  
thermostat is rated at 25 amps 240 and  
277, the disconnect is rated 20 amps 240  
and 277 VAC. Therefore, the combination  
of heaters should not exceed 20 amps at  
277 or 240 VAC.  
Controls  
Description Single Pole  
Catalog Number CB-ITS  
Rated 25 amps at 120-277 VAC. 50-110°F  
temperature range. Tamperproof and  
adjustable through discharge louver.  
Integral thermostats: wire entry from  
either end.  
Disconnect switch: mount either end.  
Thermostat and disconnect: mount  
either end.  
Relays: control section.  
Thermostat – disconnect and relay:  
control section  
Description Double Pole Thermostat  
Catalog Number CB-ITD  
Rated 25 amps at 120-277 VAC. 50-110°F  
temperature range. Tamperproof and  
adjustable through discharge louver.  
Note: Control section is attached on  
either side.  
Description Disconnect Switch  
Catalog Number CB-IDS  
Double pole rated 20 amps at 120-277  
VAC.  
Wiring Diagrams  
Wiring Diagrams Control Section  
10  
FIN-PRC003-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring  
Diagrams  
Model EWFB  
When heaters are furnished with  
controls, make certain that the heater or  
heaters do not exceed the lowest  
amperage rating of the controls  
furnished. For example, if a thermostat  
and disconnect are furnished, the  
thermostat is rated at 25 amps 240 and  
277, the disconnect is rated 20 amps 240  
and 277. Therefore, the combination of  
heaters should not exceed 20 amps at  
277 or 240.  
Field Wiring With Integral Controls  
Controls  
Description Single Pole  
Catalog Number DBCF-ITS, DBCT-ITS  
Rated 25 amps at 120-277 VAC. 50-110°F  
temperature range. Tamperproof and  
adjustable through discharge louver.  
Integral thermostats: wire entry from  
either end.  
Disconnect switch: right hand wire  
entry.  
Thermostat and disconnect: right hand  
wire entry.  
Description Double Pole Thermostat  
Catalog Number DBCF-ITD, DBCT-ITD  
Rated 25 amps at 120-277 VAC. 50-110°F  
temperature range. Tamperproof and  
adjustable through discharge louver.  
Relays: right hand wire entry – control  
section.  
Thermostat – disconnect and relay:  
right hand wire entry – control section.  
Description Disconnect Switch  
Catalog Number DBCF-IDS, DBCT-IDS  
Double pole rated 20 amps at 120-277  
VAC.  
Wiring Diagrams  
Wiring Diagrams Control Section  
FIN-PRC003-EN  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring  
Diagrams  
Model EWFB  
When heaters are furnished with  
controls, make certain that the heater or  
heaters do not exceed the lowest  
amperage rating of the controls  
furnished. For example, if a thermostat  
and disconnect are furnished, the  
thermostat is rated at 25 amps 240 and  
277 VAC, the disconnect is rated  
Field Wiring With Integral Controls  
Controls  
Description Single Pole  
Catalog Number RDBT-ITS  
Rated 25 amps at 120-277 VAC. 50-110°F  
temperature range. Tamperproof and  
adjustable through discharge louver.  
Integral thermostats: wire entry from  
either end.  
Disconnect switch: right hand wire  
entry.  
Thermostat and disconnect: right hand  
wire entry.  
Relays: right hand wire entry – control  
Description Double Pole Thermostat  
Catalog Number RDBT-ITD  
Rated 25 amps at 120-277 VAC. 50-110°F  
temperature range. Tamperproof and  
adjustable through discharge louver.  
20 amps 240 and 277 VAC. Therefore, the  
combination of heaters should not  
exceed 20 amps at 277 or 240 VAC.  
section.  
Thermostat – disconnect and relay:  
right hand wire entry – control section.  
Description Disconnect Switch  
Catalog Number RDBT-IDS  
Double pole rated 20 amps at 120-277  
VAC.  
Wiring Diagrams  
Wiring Diagrams Control Section  
12  
FIN-PRC003-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring  
Diagrams  
Model EWFB  
Catalog Number ASHDB  
Heaters Over 5' (1.52 M) Long May Have Two Heating Elements  
Wiring Diagram Heater Only  
Wiring Diagrams  
Wiring Diagrams Control Section  
FIN-PRC003-EN  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mechanical  
Specifications Model EWFB  
Heater Design: Units are of modern  
square design, constructed of specified  
materials and contain totally enclosed  
junction boxes at both ends, aluminum  
fin tube element(s), thermal overload  
and a 1/2" (13 mm) EMT prewired  
40 ampere wireway. Heater lengths  
furnished in 2 foot (0.6 M) through  
10 foot (3.0 M) in 1 foot (0.3 M)  
lengths to 15 feet (4.6 M). Front panel  
snap fit to the back panel with out  
fasteners for two-piece construction.  
Back panel is pre-punched for easy  
installation and is suitable for mullion to  
mullion installation for wall mounted  
heaters only.  
Specifications  
Natural convection heavy-duty electric  
wall fin are furnished to meet the  
specified wattage, voltage and size. Units  
installed and wired in accordance with  
the manufacturer’s recommendations  
and applicable national and local codes.  
Extended Enclosures: Are manufactured  
with solid metal grilles and extends the  
enclosure length another 6" (152 mm),  
12" (305 mm), 18" (457 mm), 24" (610  
mm), 30" (762 mm), 36" (914 mm), 42"  
(1067 mm), 48" (1219 mm), 54" (1372  
mm) and 60" (1524 mm). Heater and  
Extended Enclosure are furnished as a  
one piece unit. Used to factory mount 6"  
(152 mm) and 12" (305 mm) Control  
Sections. Left or right hand mounting of  
the Control Section must be specified.  
Maximum Length with Extended  
Mounting: Electric wall fin heaters  
designed to be securely attached to the  
wall (or optional floor mounted on  
pedestals) per manufacturer’s  
instructions. Heaters are wired for either  
right or left hand entry where there are  
no controls, otherwise entry will be in  
the junction box containing controls.  
increments.1/2" (13 mm) and 3/4  
"
(19 mm) knockouts are provided on the  
side and rear of the heaters junction box  
to allow end to end wiring for wall  
mounted units and in the bottom of the  
junction box only for floor mounted  
heaters.  
Heaters with bottom air intake and top  
air exit and front air intake (inlet grille)  
and top air exit (both wall and pedestal  
styles) must be mounted a minimum of  
3" (76 mm) off the finished floor.  
Enclosure front panel are of one piece  
construction suitable for architectural,  
commercial and industrial use, with  
1
/4" (6.4 mm) pencil-proof top air  
discharge and or front air intake louvers.  
Louvers discharge heated air at a 15  
degree angle for cleaner operation. The  
one-piece front panel is extruded for  
maximum strength and is available in  
Enclosures are 15 feet (4.6 M) for heater  
models DBT, DBF and CB, 12 feet (3.7 M)  
for heater models DBCT, DBCF and  
RDBT-PD and 10 feet (3.04 M) for heater  
model ASHDB.  
Heaters with front air intake (inlet grille)  
and top air exit can be wall mounted at  
the finished floor level and are approved  
for zero clearance at the bottom.  
14  
FIN-PRC003-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mechanical  
Specifications Model EWFB  
Model RDBT-PD – Pedestal mounted  
Enclosure Models and Type:  
Model CB – Wall mounted (bottom air  
(bottom air intake and top air outlet)  
enclosure are rounded with a flat top  
air discharge, 5" (127 mm) high x  
6" (152 mm) deep manufactured from  
12-gauge (2.7 mm) thick extruded  
aluminum. Extrusion is .100" (2.5 mm)  
thick heat treated to T-5 hardness.  
Pedestals are 2" (51 mm) high for  
overall height of 7" (178 mm) from the  
floor to the top of the enclosure.  
Maximum wattage is 300 watts per  
foot (984 watts per meter).  
inlet and top air outlet) are snap fit  
two-piece construction, 4 1/2" (114 mm)  
high x 2 5/8" (67 mm) deep  
Model DBT – Wall mounted (bottom air  
inlet and top air outlet) are snap fit two-  
piece construction, 6" (152 mm) high x  
3 1/2" (89 mm) deep manufactured from  
12-gauge (2.7 mm thickness) extruded  
aluminum. Extrusion are .100" (2.5  
mm) thick 6063 aluminum heat treated  
to T-5 hardness. Backplates are 12-  
gauge (2.7 mm thickness) extruded  
aluminum. Maximum wattage is 300  
watts per foot (984 watts per meter).  
manufactured from 14-gauge (1.9 mm  
thickness) extruded aluminum.  
Extrusion is .70" (1.8 mm) thick 6063  
aluminum heat treated to T-5 hardness.  
Backplates are 14-gauge (1.9 mm  
thickness) extruded aluminum.  
Maximum wattage is 250 watts per  
foot (820 watts per meter).  
Model DBCT – Wall mounted (bottom  
air inlet and top air outlet) are snap fit  
two-piece construction, 7" (178 mm)  
high x 5" (127 mm) deep manufactured  
from 10-gauge (3.4 mm thickness)  
extruded aluminum. Extrusion is .100"  
(2.5 mm) thick 6063 aluminum heat  
treated to T-5 hardness. Backplates are  
10-gauge (3.4 mm thickness) extruded  
aluminum. Maximum wattage is 750  
watts per foot (2460 watts per meter).  
Model DBF – Wall mounted (bottom  
Model ASHDB – Wall mounted  
front air inlet grille and top air outlet) is  
snap fit two-piece construction,  
6" (152 mm) high x 3 1/2" (89 mm) deep  
manufactured from 12-gauge (2.7 mm  
thickness) extruded aluminum.  
Extrusion is .100" (2.5 mm) thick 6063  
aluminum heat treated to T-5 hardness.  
Backplates are 12-gauge (2.7 mm  
thickness) extruded aluminum for zero  
clearance mounting. Maximum  
wattage is 250 watts per foot (820  
watts per meter).  
(bottom air inlet and top air outlet) are  
available in 8" (203 mm), 10" (254 mm),  
12" (305 mm), 14" (356 mm), 16" (406  
mm) 18" (457 mm) and 20" (508 mm)  
heights in a 5 1/2" (140 mm) depth.  
Enclosure front and back panel are  
manufactured from 16-gauge (1.5 mm  
thickness) steel and is snap fit two-  
piece construction. Discharge grille is  
12-gauge (2.7 mm thickness) one piece  
continuous extruded aluminum,  
.100" (2.5 mm) thick 6063 aluminum  
heat treated to T-5 hardness.  
Model DBCF – Wall mounted (front air  
inlet grille and top air outlet) are snap  
fit two-piece construction, 7" (178 mm)  
high x 5" (127 mm) deep manufactured  
from 10-gauge (3.4 mm thickness)  
extruded aluminum. Extrusion is .100"  
(2.5 mm) thick 6063 aluminum heat  
treated to T-5 hardness. Backplates are  
10-gauge (3.4 mm thickness) extruded  
aluminum. Maximum wattage is 650  
watts per foot (2133 watts per meter).  
Maximum wattage is 500 watts per  
foot (1640 watts per meter).  
FIN-PRC003-EN  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mechanical  
Specifications Model EWFB  
Control Options: Built-in thermostat and  
Heating Elements: Element(s) consist of  
high quality nickel chromium alloy  
resistance wire embedded and  
completely surrounded by magnesium  
oxide, enclosed and swaged in an  
aluminum sheath. Aluminum fins are  
mechanically bonded to the sheath for  
efficient heat transfer. The element  
fin temperature will not exceed  
330°F (166°C) to help assure long  
element life. The heating element is  
center anchored and free floating at each  
end on nylon bushings for quiet  
operation.  
ATR – Transformer relay single pole,  
disconnect are rated for 20 amps, 120-  
rated 25 amp 120-277 VAC contacts  
277 VAC. Transformer relay are rated 25  
rated up thru 277 volt and must be  
amp, 120-277 VAC and power relays  
specified. Coils are 24 volt and 120 volt  
rated for 18 amps. They are factory  
and must be specified.  
installed with one device per junction  
PR 208/24, 18 amp power relay  
contactor.  
box or a 6" (152 mm) long or 12" (305  
mm) long control section can be used  
PR 240/24, 18 amp power relay  
contactor.  
due to the heaters size or more than two  
controls are required per heater.  
PR 277/24, 18 amp power relay  
contactor.  
ITS – Single pole thermostat, 20 amp,  
is adjustable thru discharge grille  
factory mounted and wired in left hand  
junction box.  
ATR – Transformer relays and all  
PR-power relays require a control  
section and a 12" (305 mm) long  
extended enclosure for installation.  
Thermal Overload: A full length tubular  
automatic reset thermal overload  
disconnects the heating element(s) in the  
event normal operating temperatures  
are exceeded.  
ITD – Double pole thermostat, 20 amp,  
is adjustable thru discharge grille  
factory mounted and wired in left hand  
junction box.  
IDS – Double pole disconnect switch,  
Volts/Phase: All models available in the  
following volts and phase 208/1, 240/1,  
277/1 or 120/1.  
20 amp, is adjustable thru discharge  
grille factory mounted and wired in  
right hand junction box.  
Watts/Foot  
Watts Per Foot  
(Single Element Heaters)  
93, 125, 141, 188, 250 & 282  
Watts Per Foot  
(Double Element Heaters)  
282  
Models  
DBT &  
RDBT  
DBF &  
CB  
93, 125, 141, 188 & 250  
None  
DBCF &  
ASHDB  
DBCT  
93, 125, 141, 188, 250, 282,  
333 & 375  
93, 125, 141, 188, 250, 282,  
282, 376, 438 & 500  
282, 376, 438, 500, 564, 625,  
666 & 750  
333 & 375  
16  
FIN-PRC003-EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mechanical  
Specifications Model EWFB  
Control Sections:  
Pedestals – Pedestal brackets are  
available for floor mounting in lobbies  
and in front of windows for all models  
except ASHDB 10" (254 mm), 12" (305  
mm), 14" (356 mm), 18" (457 mm) and  
20" (508 mm) high heaters. Factory  
installed to the bottom of the unit for  
field furnished power wiring to be run  
through the center of the pedestal into  
the bottom of the units junction box for  
connection to the heater.  
Color Finish Options  
- Clear Anodized  
6" (152 mm) long control section for  
- Bronze Anodized  
- Black Anodized  
- Beige Baked Enamel* 2-7-2894  
- White Baked Enamel* 2-1-5098  
- Brown Baked Enamel* 2-7-3894  
- Black Baked Enamel* 2-6-5054  
factory mounting of 1 or 2 controls.  
Right or left side mounting are  
available with right side being  
standard. Requires one foot (0.3048 M)  
of extended enclosure for installation.  
Control sections are field wired to the  
heater.  
*Colors per Electric Wall Fin Color  
Selection Chart FIN-S-3.  
12" (305 mm) long control section for  
factory mounting of 1, 2 or 3 controls.  
Right or left side mounting are  
available with right side being  
standard. Requires one foot (0.3048 M)  
of extended enclosure for installation.  
Control sections are field wired to the  
heater.  
Anodized colors available for all  
models except Model ASHDB.  
The knockouts that are provided in the  
side and rear of each heaters junction  
box and the back panel mounting  
holes for wall mounting of units are  
not furnished when pedestals are  
ordered.  
Hydronic Heating Units  
Blank enclosure sections for use with  
hydronic heating elements are modified  
to have the air outlet grille and bottom  
air inlet or bottom front air inlet grille in  
the same configuration as listed above  
for each model electric heater.  
2' to 6' (0.6 to 1.83 M) heaters require  
two pedestals, 6' to 8' (1.83 to 2.44 M)  
heaters require three pedestals,  
9' (2.74 M) and 10' (3.05 M) heaters  
require four pedestals.  
Accessories: Accessories are approved  
as 40 ampere wireways and are of the  
same material and compatible design  
as the heater section.  
Maximum Element Fin Size per Model  
Model Maximum Fin Size  
DBT & 23/4" x 4"  
and 31/4" x 31/4  
"
Inside corners 90 - 180 degrees.  
Finished Back Panels – Finished back  
panels either painted or anodized in  
the same color as the heater are  
available for pedestal floor mounted  
heaters to be installed in front of  
windows and in lobbies.  
DBCT  
70 mm x 102 mm  
and 83 mm x 83 mm  
Outside corners 180 - 270 degrees.  
DBF & 23/4" x 4"  
and 23/4" x 3"  
and 70 mm x 76 mm  
DBCF  
70 mm x 102 mm  
End caps left or right hand.  
ASHDB 41/4" x 41/4  
"
2" (51 mm) and 6" (152 mm) wall trims.  
1 1/2" (38 mm) splice plates.  
108 mm x 108 mm  
Note:  
31/4" (83 mm) x 51/4" (133 mm) fin size and  
23/4" (70 mm) x 5" (127 mm) fin size cannot be used with  
these size enclosures.  
1
/
4" (6.4 mm) wire mesh factory  
Blank enclosure sections manufactured  
of solid metal grilles and are  
installed under outlet grille on  
enclosure and blank enclosure sections  
and extended enclosure sections.  
independent pieces of enclosure not  
joined to the heater and are fully  
enclosed to allow branch circuit wiring.  
Available in 1 foot (0.3048 M) through  
10 foot (3.048 M) lengths in 1 foot  
(0.3048 M) increments. Can be  
modified for use with hydronic heating  
elements for models DBT, DBF, DBCT,  
DBCF and ASHDB only.  
FIN-PRC003-EN  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FIN-PRC003-EN  
Literature Order Number  
File Number  
PL-TD-FIN-000-PRC003-EN-1001  
FIN-DS-5 0798  
Supersedes  
The Trane Company  
An American Standard Company  
La Crosse  
Stocking Location  
For more information contact  
your local sales office or  
e-mail us at [email protected]  
Since The Trane Company has a policy of continuous product and product data improvement, it reserves the  
right to change design and specifications without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Technicolor Thomson Universal Remote VPH6920F User Manual
Toshiba DVD Player SD K860 User Manual
TRENDnet TV Video Accessories 2 Port Video Splitter User Manual
Triarch Indoor Furnishings 29761 User Manual
Triarch Indoor Furnishings 33236 User Manual
Tripp Lite TV Cables A004 006 User Manual
True Manufacturing Company Refrigerator TCGG 48 S User Manual
Uniden Cordless Telephone EXS9600 User Manual
Uniden Flat Panel Television TL27TX1 AB W User Manual
Weed Eater Lawn Mower 164833 User Manual