Trane Furnace TDH2B060A9V3VA User Manual

Upflow/ Horizontal Left,  
Downflow/ Horizontal Right  
Variable Speed  
Two Stage Condensing  
Gas-Fired Furnace  
XV 95  
TDH2B060A9V3VA  
TDH2B080A9V3VA  
TDH2B080A9V4VA  
TDH2C100A9V4VA  
TDH2D120A9V5VA  
TUH2B060A9V3VA  
TUH2B080A9V3VA  
TUH2B080A9V4VA  
TUH2C100A9V4VA  
TUH2C100A9V5VA  
TUH2D120A9V5VA  
Direct Vent with  
Variable Speed Blower  
Variable Speed Inducer  
*DH-A9V-V  
*UH-A9V-V  
DOWNFLOW  
UPFLOW  
DOWNFLOW/HORIZONTAL  
UPFLOW/HORIZONTAL  
PUB. NO. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
General Features  
Features and Benefits  
Standard Equipment  
2
4
4
Optional Equipment  
5
General Data  
TUH2B060A9V3VA  
TUH2B080A9V3VA  
TUH2B080A9V4VA  
TUH2C100A9V4VA  
TUH2C100A9V5VA  
TUH2D120A9V5VA  
TDH2B060A9V3VA  
TDH2B080A9V3VA  
TDH2B080A9V4VA  
TDH2C100A9V4VA  
TDH2D120A9V5VA  
6-8  
Performance Data  
Venting Table  
Electrical Data  
Field Wiring  
9-19  
20  
21-24  
25-26  
27-28  
Dimensions  
3
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
and Benefits  
XV 95 STANDARD EQUIPMENT  
• Variable Speed BlowerMotor  
• Silicon Nitride Igniter with adaptive  
heat up  
• Variable speed induced draft blower  
• Direct/Non-Direct vent option  
• Fused 24 volt control circuit  
• Manual reset burner safety switches  
• Power supply 115/1/60  
• Lite Portextended system diag-  
nostics  
• Stored fault code history in micro pro-  
cessor nonvocatile memory  
• Cleanable high velocity filters (upflow  
only)  
• Hinged blower door *  
• Perfect fit door latches*  
• Insulated blower door*  
• Convertible to horizontal on left side  
• 2-stage gas valve  
• PVC venting-1 or 2 pipe option  
• Accessory hook-up capability  
• Integrated solid state control with self-  
diagnostics  
• Attractive color accents  
• Heavy gauge aluminized steel heat  
exchanger  
• Gasketed blower door*  
• Complete front service access  
• Left/right gas connection  
• Adjustable fan off times  
• Optional L.P conversion kit  
• Selectable cooling fan off delay  
eliminates need for BAY24X045  
time delay kit  
• Multi-port In-shot burners  
• Quiet induced draft blower  
* (Upflow only)  
4
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features  
and Benefits  
XV 95 OPTIONAL EQUIPMENT  
Thermostat, 2-Stage Heat / 1-Stage Cooling ........................................................................................................... TAYSTAT241 [ ]  
Thermostat, Media Programmable 2-Stage Heating..............................................................................................TAYSTAT302C [ ]  
Thermostat, Mechanical Heating Only With Fan Switch.........................................................................................TAYSTAT303C [ ]  
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ..............................................................................AY28X092 [ ]  
Thermostat, Heating/Cooling Single Stage (Mounts Vertically)................................................................................BAYSTAT305 [ ]  
Thermostat, Media Programmable 1-Stage Heating/1-Stage Cooling ...................................................................TAYSTAT300C [ ]  
Propane Conversion Kit........................................................................................................................................ BAYLPKT210A [ ]  
Media Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace)........................................................... TFM145A9FR0 [ ]  
Media Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace)........................................................... TFM175A9FR0 [ ]  
Media Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace)................................................................. TFM210A9FR0 [ ]  
Media Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace)........................................................... TFM245A9FR0 [ ]  
Media Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ....................................................TFP145A9FR0 [ ]  
Media Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ....................................................TFP175A9FR0 [ ]  
Media Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace)...........................................................TFP210A9FR0 [ ]  
Media Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ....................................................TFP245A9FR0 [ ]  
Coil Enclosure (14-1/2" Wide Cabinets) .........................................................................................................BAYCLE14A1422A [ ]  
Coil Enclosure (17-1/2" Wide Cabinets) .......................................................................................................BAYCLE17A1722A [ ]  
Coil Enclosure (21" Wide Cabinets) ..............................................................................................................BAYCLE21A2130A [ ]  
Coil Enclosure (24-1/2" Wide Cabinets) .......................................................................................................BAYCLE24A2430A [ ]  
Downflow Subbase................................................................................................................................................. BAYBASE205 [ ]  
Side Filter Rack ....................................................................................................................................................... BAYFLTR200 [ ]  
Filter Kit/Horizontal Conversion TUH2-060,080....................................................................................................... BAYFLTR203 [ ]  
Filter Kit/Horizontal Conversion TUH2-100.............................................................................................................. BAYFLTR204 [ ]  
Filter Kit/Horizontal Conversion TUH2-120.............................................................................................................. BAYFLTR205 [ ]  
High Altitude Pressure Switch Kit TUH2-060 ............................................................................................ BAYSWT10AHALTA1 [ ]  
High Altitude Pressure Switch Kit TUH2-080,100,120 .............................................................................. BAYSWT08AHALTA1 [ ]  
Concentric Vent Kit TUH2 Furnaces...............................................................................................................BAYAIR30AVENTA [ ]  
Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces............................................................................BAYVENT200B [ ]  
Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces........................................................................BAYMFGH100A [ ]  
Cleanable Filter (14.5"/17.5" wide Upflow models).................................................................................................. BAYFLTR317 [ ]  
Cleanable Filter (21" wide Upflow models).............................................................................................................. BAYFLTR321 [ ]  
Cleanable Filter (24.5" wide Upflow models)........................................................................................................... BAYFLTR324 [ ]  
CleanEffects™, Whole House Air Cleaner (Upflow 14-1/2" Wide Gas Furnace) ........................................... TFD145ALFR000B [ ]  
CleanEffects™, Whole House Air Cleaner (Upflow 17-1/2" Wide Gas Furnace) ...........................................TFD175ALFR000B [ ]  
CleanEffects™, Whole House Air Cleaner (Upflow 21" Wide Gas Furnace) ..................................................TFD210ALFR000B [ ]  
CleanEffects™, Whole House Air Cleaner (Upflow 24-1/2" Wide Gas Furnace) ...........................................TFD245ALFR000B [ ]  
CleanEffects™, Whole House Air Cleaner (Downflow 14-1/2" Wide Gas Furnace) ...................................... TFD14DALFR000B [ ]  
CleanEffects™, Whole House Air Cleaner (Downflow 17-1/2" Wide Gas Furnace) ...................................... TFD17DALFR000B [ ]  
CleanEffects™, Whole House Air Cleaner (Downflow 21" Wide Gas Furnace) ............................................ TFD21DALFR000B [ ]  
CleanEffects™, Whole House Air Cleaner (Downflow 24-1/2" Wide Gas Furnace) ...................................... TFD24DALFR000B [ ]  
CleanEffects™, Whole House Transformer Kit (120 to 24 Volt - all TFD Air Cleaners)..................................... BAYTRANS12024 [ ]  
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.  
5
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General  
Data  
TUH2 PRODUCT SPECIFICATIONS1  
1
Product Specifications  
TUH2B080A9V3VA  
MODEL  
TYPE  
TUH2B080A9V4VA  
TUH2B060A9V3VA  
TUH2C100A9V4VA  
Upflow/Horizontal  
Upflow/Horizontal  
Upflow/Horizontal  
Upflow/Horizontal  
RATINGS  
1st Stage Input BTUH  
1st Stage Capacity BTUH (ICS) 3  
2nd Stage Input BTUH  
2nd Stage Capacity BTUH (ICS) 3  
AFUE  
2
52,000  
50,440  
80,000  
77,600  
97  
52,000  
50,440  
80,000  
77,600  
97  
39,000  
37,830  
60,000  
58,200  
97  
65,000  
62,855  
100,000  
96,700  
96.7  
Temp. rise (Min.-Max.) °F.  
35 - 65  
35 - 65  
35 - 65  
35 - 65  
BLOWER DRIVE  
Diameter - Width (In.)  
No. Used  
Speeds (No.)  
CFM vs. in. w.g.  
Motor HP  
DIRECT  
10 x 8  
1
Variable  
DIRECT  
11 x 8  
1
Variable  
DIRECT  
10 x 8  
1
Variable  
DIRECT  
10 x 10  
1
Variable  
See Fan Performance Table  
1/2  
See Fan Performance Table  
3/4  
See Fan Performance Table  
1/2  
See Fan Performance Table  
3/4  
R.P.M.  
Volts/Ph/Hz  
Variable  
115/1/60  
Variable  
115/1/60  
Variable  
115/1/60  
Variable  
115/1/60  
COMBUSTION FAN -Type  
Drive - No. Speeds  
Motor HP - RPM  
Volts/Ph/Hz  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
FLA  
FILTER — Furnished?  
Type Recommended  
Hi Vel. (No.-Size-Thk.)  
Ye s  
High Velocity  
1 - 17x25 - 1 in.  
Ye s  
High Velocity  
1 - 17x25 - 1 in.  
Ye s  
High Velocity  
1 - 17x25 - 1 in.  
Ye s  
High Velocity  
1 - 20x25 - 1 in.  
VENT — Size (in.)  
2 Round  
2 Round  
2 Round  
3 Round  
HEAT EXCHANGER  
Type -Fired  
-Unfired  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Gauge (Fired)  
ORIFICES — Main  
Nat. Gas. Qty. — Drill Size  
L.P. Gas Qty. — Drill Size  
4 — 45  
4 — 56  
4 — 45  
4 — 56  
3 — 45  
3 — 56  
5 — 45  
5 — 56  
GAS VALVE  
Redundant - Two Stage  
Redundant - Two Stage  
Redundant - Two Stage  
Redundant - Two Stage  
PILOT SAFETY DEVICE  
Type  
Hot Surface Igniter  
Hot Surface Igniter  
Hot Surface Igniter  
Hot Surface Igniter  
BURNERS Type  
Number  
Multiport Inshot  
4
Multiport Inshot  
4
Multiport Inshot  
3
Multiport Inshot  
5
POWER CONN. — V/Ph/Hz 4  
Ampacity (In Amps)  
Max. Overcurrent Protection (Amps)  
115/1/60  
11.1  
15  
115/1/60  
13.5  
20  
115/1/60  
11.1  
15  
115/1/60  
13.5  
20  
PIPE CONN. SIZE (IN.)  
1/2  
1/2  
1/2  
1/2  
DIMENSIONS  
Crated (In.)  
H x W x D  
41-3/4 x 19-1/2 x 30-1/2  
H x W x D  
41-3/4 x 19-1/2 x 30-1/2  
H x W x D  
41-3/4 x 19-1/2 x 30-1/2  
H x W x D  
41-3/4 x 23 x 30-1/2  
WEIGHT  
Shipping (Lbs.)/Net (Lbs)  
168 / 156  
170 / 158  
158 / 146  
197 / 185  
1Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3  
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian  
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.  
3Based on U.S. government standard tests.  
4The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.  
6
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General  
Data  
TUH2/TDH2 PRODUCT SPECIFICATIONS1  
1
PRODUCT SPECIFICATIONS  
MODEL  
TYPE  
TUH2D120A9V5VA  
TDH2B060A9V3VA  
TDH2B080A9V3VA  
TUH2C100A9V5VA  
Upflow/Horizontal  
Downflow/Horizontal  
Downflow/Horizontal  
Upflow/Horizontal  
RATINGS  
1st Stage Input BTUH  
1st Stage Capacity BTUH (ICS) 3  
2nd Stage Input BTUH  
2nd Stage Capacity BTUH (ICS) 3  
AFUE  
2
78,000  
75,426  
120,000  
116,040  
96.7  
39,000  
37,000  
60,000  
57,000  
95  
52,000  
49,400  
80,000  
76,000  
95  
65,000  
62,855  
100,000  
96,700  
96.7  
Temp. rise (Min.-Max.) °F.  
40 - 70  
35 - 65  
35 - 65  
35 - 65  
BLOWER DRIVE  
Diameter - Width (In.)  
No. Used  
Speeds (No.)  
CFM vs. in. w.g.  
Motor HP  
DIRECT  
10 x 10  
1
Variable  
DIRECT  
10 x 8  
1
Variable  
DIRECT  
10 x 8  
1
Variable  
DIRECT  
11 x 10  
1
Variable  
See Fan Performance Table  
1
See Fan Performance Table  
1/2  
See Fan Performance Table  
1/2  
See Fan Performance Table  
1
R.P.M.  
Volts/Ph/Hz  
Variable  
115/1/60  
Variable  
115/1/60  
Variable  
115/1/60  
Variable  
115/1/60  
COMBUSTION FAN -Type  
Drive - No. Speeds  
Motor HP - RPM  
Volts/Ph/Hz  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
FLA  
FILTER — Furnished?  
Type Recommended  
Hi Vel. (No.-Size-Thk.)  
Ye s  
High Velocity  
1 - 24x25 - 1 in.  
Ye s  
High Velocity  
2 - 14x20 - 1 in.  
Ye s  
High Velocity  
2 - 14x20 - 1 in.  
Ye s  
High Velocity  
1 - 20x25 - 1 in.  
VENT — Size (in.)  
3 Round  
2 Round  
2 Round  
3 Round  
HEAT EXCHANGER  
Type -Fired  
-Unfired  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Gauge (Fired)  
ORIFICES — Main  
Nat. Gas. Qty. — Drill Size  
L.P. Gas Qty. — Drill Size  
6 — 45  
6 — 56  
3 — 45  
3 — 56  
4 — 45  
4 — 56  
5 — 45  
5 — 56  
GAS VALVE  
Redundant - Two Stage  
Redundant - Two Stage  
Redundant - Two Stage  
Redundant - Two Stage  
PILOT SAFETY DEVICE  
Type  
Hot Surface Igniter  
Hot Surface Igniter  
Hot Surface Igniter  
Hot Surface Igniter  
BURNERS Type  
Number  
Multiport Inshot  
6
Multiport Inshot  
3
Multiport Inshot  
4
Multiport Inshot  
5
POWER CONN. — V/Ph/Hz 4  
Ampacity (In Amps)  
Max. Overcurrent Protection (Amps)  
115/1/60  
15.2  
20  
115/1/60  
11.1  
15  
115/1/60  
11.1  
15  
115/1/60  
16.3  
20  
PIPE CONN. SIZE (IN.)  
1/2  
1/2  
1/2  
1/2  
DIMENSIONS  
Crated (In.)  
H x W x D  
41-3/4 x 26-1/2 x 30-1/2  
H x W x D  
41-3/4 x 19-1/2 x 30-1/2  
H x W x D  
41-3/4 x 19-1/2 x 30-1/2  
H x W x D  
41-3/4 x 23 x 30-1/2  
WEIGHT  
Shipping (Lbs.)/Net (Lbs)  
206 / 193  
160/ 146  
168 / 158  
199 / 187  
1Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3  
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian  
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.  
3Based on U.S. government standard tests.  
4The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.  
7
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General  
Data  
TDH2 PRODUCT SPECIFICATIONS1  
1
PRODUCT SPECIFICATIONS  
MODEL  
TYPE  
TDH2B080A9V4VA  
TDH2D120A9V5VA  
TDH2C100A9V4VA  
Downflow/Horizontal  
Downflow/Horizontal  
Downflow/Horizontal  
RATINGS  
1st Stage Input BTUH  
1st Stage Capacity BTUH (ICS) 3  
2nd Stage Input BTUH  
2nd Stage Capacity BTUH (ICS) 3  
AFUE  
2
52,000  
49,400  
80,000  
76,000  
95  
78,000  
74,000  
120,000  
114,000  
95  
65,000  
61,750  
100,000  
95,000  
95  
Temp. rise (Min.-Max.) °F.  
35 - 65  
40 - 70  
35 - 65  
BLOWER DRIVE  
Diameter - Width (In.)  
No. Used  
Speeds (No.)  
CFM vs. in. w.g.  
Motor HP  
DIRECT  
11 x 8  
1
Variable  
DIRECT  
10 x 10  
1
Variable  
DIRECT  
10 x 10  
1
Variable  
See Fan Performance Table  
3/4  
See Fan Performance Table  
1
See Fan Performance Table  
3/4  
R.P.M.  
Volts/Ph/Hz  
Variable  
115/1/60  
Variable  
115/1/60  
Variable  
115/1/60  
COMBUSTION FAN -Type  
Drive - No. Speeds  
Motor HP - RPM  
Volts/Ph/Hz  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
Centrifugal  
Direct - Variable  
1/50 - 5000  
33 - 110/3/60 - 180  
1.0  
FLA  
FILTER — Furnished?  
Type Recommended  
Hi Vel. (No.-Size-Thk.)  
Ye s  
High Velocity  
2 - 14x20 - 1 in.  
Ye s  
High Velocity  
2 - 16x20 - 1 in.  
Ye s  
High Velocity  
2 - 16x20 - 1 in.  
VENT — Size (in.)  
2 Round  
3 Round  
3 Round  
HEAT EXCHANGER  
Type -Fired  
-Unfired  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Aluminized Steel - Type I  
20  
Gauge (Fired)  
ORIFICES — Main  
Nat. Gas. Qty. — Drill Size  
L.P. Gas Qty. — Drill Size  
4 — 45  
4 — 56  
6 — 45  
6 — 56  
5 — 45  
5 — 56  
GAS VALVE  
Redundant - Two Stage  
Redundant - Two Stage  
Redundant - Two Stage  
PILOT SAFETY DEVICE  
Type  
Hot Surface Igniter  
Hot Surface Igniter  
Hot Surface Igniter  
BURNERS Type  
Number  
Multiport Inshot  
4
Multiport Inshot  
6
Multiport Inshot  
5
POWER CONN. — V/Ph/Hz 4  
Ampacity (In Amps)  
Max. Overcurrent Protection (Amps)  
115/1/60  
13.5  
20  
115/1/60  
15.2  
20  
115/1/60  
13.5  
20  
PIPE CONN. SIZE (IN.)  
1/2  
1/2  
1/2  
DIMENSIONS  
Crated (In.)  
H x W x D  
41-3/4 x 19-1/2 x 30-1/2  
H x W x D  
41-3/4 x 26-1/2 x 30-1/2  
H x W x D  
41-3/4 x 23 x 30-1/2  
WEIGHT  
Shipping (Lbs.)/Net (Lbs)  
172 / 160  
206 / 196  
185 / 175  
8
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st Stage Capacity = 37,830  
2nd Stage Capacity = 58,200  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
-
CFM  
TEMP. RISE  
WATTS  
600  
57  
85  
600  
57  
110  
600  
57  
155  
600  
57  
190  
LOW  
MEDIUM LOW  
NORMAL **  
HIGH  
ON  
ON  
CFM  
TEMP. RISE  
WATTS  
700  
49  
90  
700  
49  
130  
700  
49  
175  
700  
49  
210  
OFF  
ON  
ON  
OFF  
OFF  
ON  
-
-
-
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
775  
44  
105  
775  
44  
155  
775  
44  
195  
775  
44  
240  
CFM  
TEMP. RISE  
WATTS  
870  
39  
135  
870  
39  
185  
870  
39  
235  
870  
39  
290  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
860  
61  
140  
920  
57  
200  
920  
57  
245  
920  
57  
300  
670  
79  
245  
LOW  
CFM  
TEMP. RISE  
WATTS  
1000  
53  
190  
1000  
53  
255  
1000  
53  
305  
1000  
53  
340  
700  
75  
255  
MEDIUM LOW  
NORMAL **  
HIGH  
OFF  
ON  
ON  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1125  
47  
250  
1125  
47  
315  
1125  
47  
370  
1025  
51  
355  
775  
68  
285  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1250  
42  
340  
1250  
42  
405  
1250  
42  
445  
1100  
48  
390  
1000  
53  
355  
OFF  
NOTES: * First letter may be "A" or "T"  
** Factory setting  
*UH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
-
LOW  
(350 CFM/TON)  
CFM  
WATTS  
575  
65  
575  
90  
575  
125  
550  
155  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
640  
70  
640  
110  
640  
140  
630  
175  
1.5  
2.0  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
-
-
-
-
-
-
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
700  
85  
700  
125  
700  
160  
700  
200  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
700  
100  
700  
130  
700  
170  
700  
210  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
800  
115  
800  
155  
800  
200  
800  
250  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
900  
140  
900  
195  
900  
240  
900  
290  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
875  
130  
875  
180  
875  
230  
875  
270  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1000  
175  
1000  
235  
1000  
285  
1000  
335  
900  
310  
2.5  
3
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1125  
235  
1125  
295  
1125  
345  
1100  
370  
925  
318  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1050  
195  
1050  
260  
1050  
305  
1050  
350  
920  
315  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1200  
275  
1200  
330  
1200  
385  
1100  
385  
940  
330  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1325  
360  
1325  
425  
1300  
460  
1175  
425  
1000  
365  
NOTES: * First letter may be "A" or "T"  
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
9
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st Stage Capacity = 50,440  
2nd Stage Capacity = 77,600  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
800  
56  
105  
800  
56  
140  
800  
56  
180  
800  
56  
220  
800  
56  
265  
LOW  
ON  
ON  
CFM  
TEMP. RISE  
WATTS  
860  
52  
115  
880  
51  
165  
890  
50  
215  
920  
48  
265  
910  
49  
320  
MEDIUM LOW  
OFF  
ON  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
960  
46  
150  
990  
45  
200  
1000  
44  
230  
1020  
44  
310  
1010  
44  
350  
NORMAL **  
OFF  
CFM  
TEMP. RISE  
WATTS  
1080  
41  
195  
1110  
40  
255  
1120  
40  
315  
1120  
40  
365  
1080  
41  
390  
HIGH  
LOW  
OFF  
ON  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1100  
62  
205  
1100  
62  
260  
1120  
61  
320  
1120  
61  
370  
1090  
63  
400  
CFM  
TEMP. RISE  
WATTS  
1210  
57  
265  
1240  
55  
340  
1260  
54  
410  
1260  
54  
470  
1130  
61  
430  
MEDIUM LOW  
OFF  
ON  
ON  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1360  
50  
365  
1390  
49  
445  
1400  
49  
500  
1360  
50  
535  
1210  
57  
475  
NORMAL **  
OFF  
CFM  
TEMP. RISE  
WATTS  
1360  
50  
355  
1390  
49  
450  
1400  
49  
520  
1350  
51  
535  
1180  
58  
465  
HIGH  
OFF  
OFF  
NOTES: * First letter may be "A" or "T"  
** Factory setting  
*UH2B080A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
OUTDOOR  
UNIT SIZE  
(TONS)  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
OFF  
ON  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
NORMAL  
(400 CFM/TON)  
HIGH  
(450 CFM/TON)  
LOW  
(350 CFM/TON)  
NORMAL  
(400 CFM/TON)  
HIGH  
(450 CFM/TON)  
LOW  
(350 CFM/TON)  
NORMAL  
(400 CFM/TON)  
HIGH  
(450 CFM/TON)  
LOW  
(350 CFM/TON)  
NORMAL  
(400 CFM/TON)  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
CFM  
WATTS  
CFM  
WATTS  
CFM  
WATTS  
CFM  
WATTS  
CFM  
WATTS  
CFM  
WATTS  
CFM  
WATTS  
CFM  
WATTS  
CFM  
WATTS  
CFM  
WATTS  
CFM  
WATTS  
750  
84  
840  
109  
940  
136  
850  
113  
960  
150  
1080  
195  
1020  
175  
1170  
240  
1290  
310  
1170  
250  
1360  
365  
1360  
355  
750  
122  
750  
154  
720  
185  
710  
221  
820  
264  
940  
318  
890  
295  
1010  
350  
1080  
390  
1050  
375  
1130  
420  
1150  
440  
1100  
405  
1210  
475  
1180  
460  
840  
146  
840  
181  
840  
226  
2.0  
2.5  
3.0  
3.5  
ON  
ON  
OFF  
OFF  
ON  
940  
177  
940  
215  
940  
274  
ON  
ON  
850  
150  
870  
200  
890  
250  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
990  
200  
1000  
230  
1020  
305  
ON  
OFF  
OFF  
ON  
1110  
255  
1120  
315  
1120  
365  
ON  
1020  
225  
1040  
280  
1050  
330  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
1180  
300  
1200  
365  
1200  
415  
ON  
OFF  
OFF  
ON  
1320  
410  
1350  
470  
1340  
520  
ON  
1190  
315  
1210  
370  
1210  
435  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
1390  
445  
1400  
500  
1360  
535  
OFF  
OFF  
1390  
450  
1400  
520  
1350  
535  
NOTES: * First letter may be "A" or "T"  
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
10  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st Stage Capacity = 50,440  
2nd Stage Capacity = 77,600  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
800  
56  
105  
800  
56  
140  
800  
56  
180  
800  
56  
220  
800  
56  
265  
LOW  
MEDIUM LOW  
NORMAL **  
HIGH  
ON  
ON  
CFM  
TEMP. RISE  
WATTS  
860  
52  
115  
880  
51  
165  
890  
50  
215  
920  
48  
265  
910  
49  
320  
OFF  
ON  
ON  
OFF  
OFF  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
960  
46  
150  
990  
45  
200  
1000  
44  
230  
1020  
44  
310  
1010  
44  
350  
CFM  
TEMP. RISE  
WATTS  
1080  
41  
195  
1110  
40  
255  
1120  
40  
315  
1120  
40  
365  
1080  
41  
390  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1100  
62  
205  
1100  
62  
260  
1120  
61  
320  
1120  
61  
370  
1090  
63  
400  
LOW  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1210  
57  
265  
1240  
55  
340  
1260  
54  
410  
1260  
54  
470  
1130  
61  
430  
MEDIUM LOW  
NORMAL **  
HIGH  
OFF  
ON  
ON  
CFM  
TEMP. RISE  
WATTS  
1360  
50  
365  
1390  
49  
445  
1400  
49  
500  
1360  
50  
535  
1210  
57  
475  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1360  
50  
355  
1390  
49  
450  
1400  
49  
520  
1350  
51  
535  
1180  
58  
465  
OFF  
NOTES: * First letter may be "A" or "T"  
** Factory setting  
*UH2B080A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
857  
107  
849  
143  
841  
179  
833  
223  
825  
266  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
970  
158  
971  
205  
973  
251  
966  
298  
960  
345  
2.5  
3.0  
3.5  
4.0  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1082  
209  
1093  
266  
1104  
323  
1099  
374  
1095  
424  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1004  
153  
1019  
210  
1035  
267  
1038  
321  
1041  
374  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1163  
249  
1173  
311  
1184  
372  
1179  
426  
1174  
480  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1323  
345  
1328  
411  
1332  
477  
1320  
532  
1307  
586  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1176  
254  
1188  
317  
1200  
380  
1195  
437  
1190  
494  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1356  
379  
1362  
446  
1368  
514  
1353  
568  
1339  
623  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1536  
503  
1536  
575  
1536  
647  
1512  
699  
1488  
751  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1376  
374  
1367  
429  
1359  
483  
1354  
547  
1348  
611  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1562  
530  
1562  
604  
1563  
677  
1531  
720  
1499  
765  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1768  
757  
1759  
830  
1749  
902  
1654  
866  
1559  
829  
NOTES: * First letter may be "A" or "T"  
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
11  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UH2C100A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st Stage Capacity = 62,855  
2nd Stage Capacity = 96,700  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
873  
64  
100  
971  
58  
115  
1136  
49  
160  
1258  
44  
225  
893  
63  
145  
997  
56  
170  
1146  
49  
230  
1298  
43  
300  
900  
62  
195  
1006  
56  
220  
1165  
48  
295  
1319  
42  
390  
899  
62  
240  
1022  
55  
280  
1180  
47  
365  
1328  
42  
450  
902  
62  
290  
1029  
54  
335  
1184  
47  
425  
1286  
44  
490  
LOW  
MEDIUM LOW  
MEDIUM **  
HIGH  
ON  
ON  
OFF  
ON  
ON  
OFF  
OFF  
ON  
HEATING  
1ST  
STAGE  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1260  
68  
213  
1304  
66  
305  
1329  
65  
380  
1334  
65  
460  
1317  
65  
510  
LOW  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
1464  
59  
315  
1631  
53  
450  
1846  
47  
640  
1471  
59  
405  
1678  
51  
570  
1867  
46  
760  
1478  
58  
485  
1690  
51  
670  
1794  
48  
770  
1478  
58  
560  
1579  
55  
645  
1644  
52  
700  
1350  
64  
540  
1419  
61  
585  
1498  
57  
650  
MEDIUM LOW  
MEDIUM **  
HIGH  
OFF  
ON  
ON  
HEATING  
2ND  
STAGE  
OFF  
OFF  
OFF  
NOTES: * First letter may be "A" or "T"  
** Factory setting  
*UH2C100A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
OUTDOOR  
UNIT SIZE  
(TONS)  
AIRFLOW  
SETTING  
0.1  
0.3  
0.5  
0.7  
0.9  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
OFF  
ON  
SW 4  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
808  
75  
824  
125  
840  
170  
835  
210  
830  
250  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
938  
100  
963  
160  
959  
205  
964  
255  
975  
310  
2.5  
3.0  
3.5  
4.0  
ON  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1058  
150  
1100  
200  
1121  
265  
1136  
330  
1142  
395  
ON  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1004  
120  
1010  
175  
1027  
230  
1044  
285  
1050  
345  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1141  
170  
1190  
245  
1214  
310  
1229  
380  
1234  
450  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1336  
250  
1375  
330  
1387  
410  
1388  
480  
1384  
545  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1153  
180  
1206  
250  
1230  
320  
1239  
395  
1244  
460  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1390  
285  
1418  
465  
1439  
445  
1441  
515  
1373  
540  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1575  
400  
1606  
495  
1632  
590  
1596  
645  
1445  
590  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1388  
290  
1423  
360  
1444  
440  
1444  
515  
1390  
540  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1610  
415  
1641  
515  
1666  
635  
1607  
650  
1449  
595  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1847  
630  
1863  
735  
1816  
780  
1687  
720  
1532  
665  
NOTES: *First letter may be "A" or "T"  
1. At Continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
12  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UH2C100A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st Stage Capacity = 62,855  
2nd Stage Capacity = 96,700  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
873  
64  
100  
893  
63  
145  
900  
62  
195  
899  
62  
240  
902  
62  
290  
LOW  
MEDIUM LOW  
MEDIUM **  
HIGH  
ON  
ON  
CFM  
TEMP. RISE  
WATTS  
971  
58  
115  
997  
56  
170  
1006  
56  
220  
1022  
55  
280  
1029  
54  
335  
OFF  
ON  
ON  
OFF  
OFF  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1136  
49  
160  
1146  
49  
230  
1165  
48  
295  
1180  
47  
365  
1184  
47  
425  
CFM  
TEMP. RISE  
WATTS  
1258  
44  
225  
1298  
43  
300  
1319  
42  
390  
1328  
42  
450  
1286  
44  
490  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1260  
68  
213  
1304  
66  
305  
1329  
65  
380  
1334  
65  
460  
1317  
65  
510  
LOW  
CFM  
TEMP. RISE  
WATTS  
1464  
59  
315  
1471  
59  
405  
1478  
58  
485  
1478  
58  
560  
1350  
64  
540  
MEDIUM LOW  
MEDIUM **  
HIGH  
OFF  
ON  
ON  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1631  
53  
450  
1678  
51  
570  
1690  
51  
670  
1579  
55  
645  
1419  
61  
585  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1846  
47  
640  
1867  
46  
760  
1794  
48  
770  
1644  
52  
700  
1498  
57  
650  
OFF  
NOTES:  
* First letter may be "A" or "T"  
** Factory setting  
*UH2C100A9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
OFF  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1163  
222  
1201  
304  
1209  
375  
1200  
433  
1199  
495  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1339  
331  
1365  
400  
1366  
477  
1377  
555  
1382  
636  
3.5  
4.0  
5.0  
OFF  
OFF  
ON  
ON  
OFF  
ON  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1515  
440  
1538  
535  
1549  
620  
1553  
708  
1547  
796  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1339  
331  
1365  
400  
1366  
477  
1377  
555  
1382  
636  
ON  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1550  
471  
1562  
550  
1574  
645  
1575  
733  
1564  
813  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1744  
626  
1758  
736  
1770  
838  
1772  
935  
1760  
1018  
ON  
OFF  
OFF  
OFF  
OFF  
ON  
OFF  
OFF  
ON  
OFF  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1695  
578  
1709  
728  
1721  
820  
1772  
930  
1711  
1007  
OFF  
OFF  
OFF  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1919  
862  
1919  
958  
1905  
1043  
1831  
1043  
1709  
982  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NA  
NOTES: *First letter may be "A" or "T"  
1. At Continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
3. NA = Not allowed.  
13  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*UH2D120A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st Stage Capacity = 75,426  
2nd Stage Capacity = 116,040  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
1090  
62  
165  
1120  
60  
225  
1080  
63  
270  
1070  
63  
310  
1010  
67  
380  
LOW  
MEDIUM LOW  
NORMAL **  
HIGH  
ON  
ON  
CFM  
TEMP. RISE  
WATTS  
1210  
56  
220  
1200  
56  
280  
1200  
56  
330  
1180  
57  
395  
1160  
58  
455  
OFF  
ON  
ON  
OFF  
OFF  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1340  
50  
295  
1360  
50  
350  
1370  
49  
425  
1380  
49  
495  
1330  
51  
535  
CFM  
TEMP. RISE  
WATTS  
1430  
47  
390  
1570  
43  
490  
1580  
43  
565  
1570  
43  
625  
1390  
49  
565  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1660  
63  
485  
1690  
62  
590  
1680  
62  
640  
1640  
64  
675  
1460  
72  
600  
LOW  
CFM  
TEMP. RISE  
WATTS  
1870  
56  
675  
1870  
56  
745  
1810  
58  
770  
1680  
62  
715  
1490  
70  
625  
MEDIUM LOW  
NORMAL **  
HIGH  
OFF  
ON  
ON  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
2060  
51  
880  
1990  
53  
890  
1850  
57  
810  
1710  
61  
750  
1530  
68  
665  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
2200  
48  
1030  
2090  
50  
965  
1940  
54  
895  
1790  
58  
830  
1640  
64  
750  
OFF  
NOTES:  
* First letter may be "A" or "T"  
** Factory setting  
*UH2D120A9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
OFF  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1210  
220  
1210  
270  
1220  
325  
1230  
400  
1230  
445  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1400  
305  
1440  
390  
1450  
465  
1450  
510  
1410  
560  
3.5  
4.0  
5
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1590  
425  
1600  
520  
1610  
600  
1600  
645  
1380  
575  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1390  
305  
1400  
375  
1430  
445  
1440  
515  
1420  
565  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1620  
420  
1650  
530  
1670  
595  
1640  
660  
1480  
600  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1840  
600  
1830  
690  
1820  
765  
1670  
700  
1490  
620  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1800  
570  
1780  
630  
1780  
705  
1700  
695  
1530  
615  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
2050  
845  
2010  
875  
1860  
805  
1710  
735  
1530  
655  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
2160  
995  
2040  
935  
1920  
875  
1780  
805  
1620  
730  
NOTES: * First letter may be "A" or "T"  
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
14  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*DH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st STAGE CAPACITY = 37,440  
2nd STAGE CAPACITY = 57,600  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
600  
56  
55  
600  
56  
85  
600  
56  
120  
600  
56  
150  
600  
56  
185  
LOW  
MEDIUM LOW  
NORMAL **  
HIGH  
ON  
ON  
CFM  
TEMP. RISE  
WATTS  
675  
50  
65  
675  
50  
105  
675  
50  
140  
675  
50  
175  
675  
50  
205  
OFF  
ON  
ON  
OFF  
OFF  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
750  
45  
85  
750  
45  
125  
750  
45  
160  
750  
45  
210  
750  
45  
260  
CFM  
TEMP. RISE  
WATTS  
850  
40  
115  
850  
40  
155  
850  
40  
205  
850  
40  
260  
850  
40  
320  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
900  
58  
125  
900  
58  
165  
900  
58  
220  
900  
58  
270  
900  
58  
315  
LOW  
CFM  
TEMP. RISE  
WATTS  
1000  
52  
170  
1050  
50  
230  
1050  
50  
295  
1050  
50  
335  
1050  
50  
370  
MEDIUM LOW  
NORMAL **  
HIGH  
OFF  
ON  
ON  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1100  
47  
215  
1150  
45  
285  
1150  
45  
340  
1150  
45  
395  
1100  
47  
440  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1300  
40  
330  
1325  
39  
385  
1325  
39  
455  
1250  
42  
465  
1200  
43  
470  
OFF  
NOTES:  
* First letter may be "A" or "T"  
** Factory setting  
*DH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
OFF  
SW 2  
OFF  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
525  
45  
525  
70  
525  
100  
525  
135  
525  
160  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
600  
55  
600  
85  
600  
120  
600  
150  
600  
185  
1.5  
2.0  
2.5  
3
OFF  
OFF  
ON  
OFF  
OFF  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
675  
65  
675  
105  
625  
140  
675  
175  
675  
205  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
700  
70  
700  
115  
700  
145  
700  
185  
700  
220  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
800  
100  
800  
135  
800  
175  
800  
225  
800  
280  
ON  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
900  
125  
900  
165  
900  
220  
900  
270  
900  
330  
ON  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
875  
115  
875  
160  
875  
210  
875  
260  
875  
310  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1000  
150  
1000  
207  
1000  
265  
1000  
320  
1000  
380  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1125  
215  
1125  
285  
1125  
340  
1125  
395  
1125  
440  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1050  
175  
1050  
240  
1050  
305  
1050  
345  
1050  
380  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1200  
240  
1200  
315  
1200  
385  
1200  
440  
1100  
410  
ON  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1350  
330  
1350  
410  
1350  
500  
1275  
485  
1170  
450  
ON  
NOTES: * First letter may be "A" or "T"  
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
15  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*DH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st STAGE CAPACITY = 49,920  
2nd STAGE CAPACITY = 76,800  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
-
CFM  
TEMP. RISE  
WATTS  
800  
56  
130  
800  
56  
170  
800  
56  
210  
790  
56  
245  
LOW  
MEDIUM LOW  
NORMAL **  
HIGH  
ON  
ON  
CFM  
TEMP. RISE  
WATTS  
900  
49  
162  
900  
49  
210  
900  
49  
260  
900  
49  
295  
OFF  
ON  
ON  
OFF  
OFF  
ON  
-
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1000  
44  
205  
1000  
44  
265  
1000  
44  
310  
1000  
44  
345  
800  
56  
295  
CFM  
TEMP. RISE  
WATTS  
1170  
38  
305  
1170  
38  
350  
1170  
38  
400  
1020  
44  
360  
830  
54  
310  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1150  
60  
285  
1150  
60  
345  
1150  
60  
385  
1020  
67***  
360  
830  
83***  
305  
LOW  
CFM  
TEMP. RISE  
WATTS  
1275  
54  
380  
1275  
54  
445  
1200  
57  
425  
1040  
66***  
380  
900  
76***  
350  
MEDIUM LOW  
NORMAL **  
HIGH  
OFF  
ON  
ON  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1430  
48  
515  
1340  
51  
490  
1220  
56  
455  
1090  
63  
410  
930  
74***  
380  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
1430  
48  
515  
1340  
51  
490  
1220  
56  
455  
1090  
63  
410  
930  
74***  
380  
OFF  
NOTES: * - First letter may be "A" or "T"  
** Factory setting  
*** Above MAX Temperature change value  
*DH2B080A9V3V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
700  
95  
700  
105  
700  
115  
680  
200  
670  
235  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
800  
130  
800  
160  
800  
205  
790  
245  
740  
265  
2.0  
2.5  
3.0  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
900  
160  
900  
215  
900  
255  
900  
300  
750  
270  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
875  
145  
875  
185  
875  
240  
875  
280  
760  
270  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1000  
205  
1000  
265  
1000  
310  
1000  
340  
800  
295  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1150  
295  
1150  
340  
1150  
385  
1020  
350  
800  
300  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1050  
235  
1050  
295  
1050  
340  
1010  
350  
800  
290  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1200  
335  
1200  
385  
1200  
410  
1040  
365  
840  
310  
ON  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1350  
455  
1350  
480  
1210  
435  
1070  
390  
900  
345  
ON  
NOTES: * First letter may be "A" or "T"  
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
16  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*DH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st STAGE CAPACITY = 49,400  
2nd STAGE CAPACITY = 76,000  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
-
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
800  
56  
130  
900  
49  
162  
1000  
44  
205  
1170  
38  
305  
800  
56  
170  
900  
49  
210  
1000  
44  
265  
1170  
38  
350  
800  
56  
210  
900  
49  
260  
1000  
44  
310  
1170  
38  
400  
790  
56  
245  
900  
49  
295  
1000  
44  
345  
1020  
44  
360  
LOW  
MEDIUM LOW  
MEDIUM **  
HIGH  
ON  
ON  
OFF  
ON  
ON  
OFF  
OFF  
ON  
-
HEATING  
1ST  
STAGE  
800  
56  
295  
830  
54  
310  
830  
83***  
305  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1150  
60  
285  
1150  
60  
345  
1150  
60  
385  
1020  
67***  
360  
LOW  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
1275  
54  
380  
1430  
48  
515  
1430  
48  
515  
1275  
54  
445  
1340  
51  
490  
1340  
51  
490  
1200  
57  
425  
1220  
56  
455  
1220  
56  
455  
1040  
66***  
380  
1090  
63  
410  
1090  
63  
900  
76***  
350  
930  
74***  
380  
930  
74***  
380  
MEDIUM LOW  
MEDIUM **  
HIGH  
OFF  
ON  
ON  
HEATING  
2ND  
STAGE  
OFF  
OFF  
OFF  
410  
NOTES: * - First letter may be "A" or "T"  
** Factory setting  
*** Above MAX Temperature change value  
*DH2B080A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
849  
141  
865  
191  
881  
241  
878  
294  
876  
348  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
953  
195  
965  
250  
977  
305  
973  
358  
970  
411  
2.5  
3.0  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1057  
249  
1065  
309  
1073  
369  
1069  
422  
1064  
474  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
999  
188  
1003  
241  
1008  
394  
1018  
354  
1029  
414  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1144  
300  
1150  
362  
1156  
423  
1160  
486  
1165  
548  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1288  
412  
1297  
482  
1305  
552  
1303  
617  
1300  
682  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1156  
307  
1165  
374  
1174  
440  
1177  
502  
1179  
563  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1327  
446  
1335  
518  
1343  
589  
1325  
641  
1307  
693  
3.5  
4.0  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1506  
634  
1502  
703  
1498  
771  
1418  
746  
1338  
721  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1327  
446  
1335  
518  
1343  
589  
1325  
641  
1307  
693  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1525  
656  
1522  
727  
1518  
797  
1430  
761  
1341  
725  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1706  
906  
1635  
881  
1563  
857  
1471  
813  
1379  
769  
NOTES: * First letter may be "A" or "T"  
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
17  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*DH2C100A9V4V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st STAGE CAPACITY = 62,400  
2nd STAGE CAPACITY = 96,000  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 7  
SW 8  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
923  
61  
110  
1020  
55  
145  
1156  
48  
185  
1275  
44  
225  
955  
59  
165  
1047  
53  
190  
1166  
48  
240  
1305  
43  
290  
960  
58  
210  
1053  
53  
250  
1172  
48  
300  
1328  
42  
365  
958  
58  
265  
1042  
54  
295  
1177  
48  
350  
1328  
42  
445  
947  
59  
310  
1029  
54  
350  
1178  
48  
420  
1328  
42  
510  
LOW  
MEDIUM LOW  
MEDIUM **  
HIGH  
ON  
ON  
OFF  
ON  
ON  
OFF  
OFF  
ON  
HEATING  
1ST  
STAGE  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1298  
66  
235  
1320  
65  
305  
1335  
65  
380  
1343  
64  
445  
1343  
64  
520  
LOW  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
CFM  
TEMP. RISE  
WATTS  
1439  
60  
310  
1639  
53  
430  
1790  
18  
570  
1459  
59  
390  
1650  
52  
525  
1818  
47  
670  
1482  
58  
470  
1650  
52  
600  
1813  
47  
770  
1483  
58  
550  
1644  
52  
680  
1708  
50  
750  
1470  
59  
610  
1496  
58  
640  
1535  
56  
675  
MEDIUM LOW  
MEDIUM **  
HIGH  
OFF  
ON  
ON  
HEATING  
2ND  
STAGE  
OFF  
OFF  
OFF  
NOTES: * - First letter may be "A" or "T"  
** Factory setting  
*** Above MAX temperature change  
*DH2C100A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
ON  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
870  
100  
885  
140  
887  
185  
881  
230  
876  
270  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
989  
120  
1018  
180  
1016  
230  
1012  
285  
999  
325  
2.5  
3.0  
ON  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1124  
175  
1139  
225  
1130  
275  
1135  
335  
1135  
390  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1053  
145  
1075  
200  
1070  
245  
1070  
295  
1049  
350  
OFF  
OFF  
OFF  
ON  
ON  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1186  
195  
1205  
255  
1220  
310  
1220  
370  
1216  
440  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1336  
255  
1366  
340  
1383  
405  
1385  
470  
1381  
545  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1216  
190  
1225  
255  
1235  
320  
1240  
385  
1243  
445  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1394  
270  
1422  
360  
1436  
430  
1437  
505  
1430  
580  
3.5  
4.0  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1579  
395  
1604  
475  
1610  
555  
1599  
645  
1517  
640  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1377  
270  
1412  
355  
1426  
430  
1433  
510  
1428  
575  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1599  
425  
1624  
510  
1636  
585  
1618  
670  
1512  
635  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1801  
580  
1818  
690  
1815  
775  
1694  
735  
1525  
660  
NOTES: * - First letter may be "A" or "T"  
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
18  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*DH2D120A9V5V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
1st STAGE CAPACITY = 74,880  
2nd STAGE CAPACITY = 115,200  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 8  
SW 7  
0.1  
0.3  
0.5  
0.7  
0.9  
CFM  
TEMP. RISE  
WATTS  
1025  
65  
150  
1025  
65  
200  
1000  
67  
240  
1000  
67  
290  
1000  
67  
340  
LOW  
ON  
ON  
CFM  
TEMP. RISE  
WATTS  
1200  
56  
230  
1200  
56  
270  
1200  
56  
330  
1200  
56  
390  
1200  
56  
450  
MEDIUM LOW  
OFF  
ON  
ON  
OFF  
OFF  
ON  
HEATING  
1ST  
STAGE  
CFM  
TEMP. RISE  
WATTS  
1350  
49  
280  
1350  
49  
340  
1350  
49  
490  
1350  
49  
470  
1350  
49  
530  
NORMAL **  
HIGH  
CFM  
TEMP. RISE  
WATTS  
1550  
43  
400  
1550  
43  
490  
1550  
43  
560  
1550  
43  
620  
1450  
46  
600  
OFF  
ON  
CFM  
TEMP. RISE  
WATTS  
1550  
66  
380  
1550  
66  
470  
1550  
66  
540  
1550  
66  
610  
1450  
71***  
690  
LOW  
CFM  
TEMP. RISE  
WATTS  
1850  
56  
660  
1850  
56  
750  
1850  
56  
780  
1700  
60  
720  
1500  
69  
640  
MEDIUM LOW  
NORMAL **  
HIGH  
OFF  
ON  
ON  
HEATING  
2ND  
STAGE  
CFM  
TEMP. RISE  
WATTS  
2050  
50  
860  
2000  
51  
880  
1850  
56  
810  
1700  
60  
750  
1550  
66  
670  
OFF  
OFF  
CFM  
TEMP. RISE  
WATTS  
2105  
49  
1000  
2050  
50  
940  
1900  
54  
880  
1775  
58  
820  
1625  
63  
750  
OFF  
NOTES:  
* First letter may be "A" or "T"  
** Factory setting  
*DH2D120A9V5V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER  
OUTDOOR  
UNIT SIZE  
(TONS)  
DIP SWITCH SETTING  
EXTERNAL STATIC PRESSURE  
AIRFLOW  
SETTING  
SW 1  
OFF  
SW 2  
ON  
SW 3  
OFF  
SW 4  
ON  
0.1  
0.3  
0.5  
0.7  
0.9  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1225  
240  
1225  
280  
1225  
340  
1225  
400  
1225  
450  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1400  
310  
1400  
390  
1400  
470  
1400  
520  
1400  
570  
3.5  
4.0  
5
OFF  
OFF  
ON  
ON  
ON  
OFF  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1600  
450  
1600  
520  
1600  
590  
1600  
640  
1450  
600  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1400  
300  
1400  
380  
1400  
450  
1400  
520  
1400  
570  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
1600  
460  
1600  
530  
1600  
610  
1600  
670  
1450  
600  
ON  
OFF  
OFF  
ON  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
1800  
610  
1800  
700  
1800  
760  
1650  
690  
1500  
630  
ON  
LOW  
(350 CFM/TON)  
CFM  
WATTS  
1750  
580  
1750  
640  
1750  
720  
1650  
680  
1450  
610  
OFF  
OFF  
OFF  
OFF  
OFF  
ON  
NORMAL  
(400 CFM/TON)  
CFM  
WATTS  
2000  
830  
2000  
860  
1850  
800  
1700  
740  
1550  
660  
OFF  
OFF  
HIGH  
(450 CFM/TON)  
CFM  
WATTS  
2100  
970  
2000  
910  
1900  
850  
1650  
780  
1600  
710  
NOTES: * - First letter may be "A" or "T"  
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.  
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;  
NORMAL airflow (400 cfm/ton) is typical setting;  
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.  
19  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maximum Vent  
Length Table  
VENT LENGTH TABLE  
ALTITUDE  
MAXIMUM TOTAL EQUIVALENT LENGTH IN FEET  
FOR VENT AND INLET AIR (SEE NOTES)  
0-7,000 Feet  
2 INCH PIPE  
200  
2.5 INCH PIPE  
200  
3 or 4 INCH PIPE  
200  
*UH/DH2B060A9V3VA  
*UH/DH2B080A9V3VA  
*UH/DH2B080A9V4VA  
50  
120  
60  
200  
200  
*UH/DH2C100A9V4VA  
*UH2C100A9V5VA  
Not Allowed  
*UH/DH2D120A9V5VA  
7,000-9,500 Feet  
Not Allowed  
2 INCH PIPE  
100  
Not Allowed  
2.5 INCH PIPE  
100  
200  
3 or 4 INCH PIPE  
100  
*UH/DH2B060A9V3VA  
*UH/DH2B080A9V3VA  
*UH/DH2B080A9V4VA  
25  
60  
30  
100  
100  
*UH/DH2C100A9V4VA  
*UH2C100A9V5VA  
Not Allowed  
*UH/DH2D120A9V5VA  
9,500-12,000 Feet  
Not Allowed  
2 INCH PIPE  
50  
Not Allowed  
2.5 INCH PIPE  
50  
100  
3 or 4 INCH PIPE  
50  
*UH/DH2B060A9V3VA  
*UH/DH2B080A9V3VA  
*UH/DH2B080A9V4VA  
Not Allowed  
30  
50  
*UH/DH2C100A9V4VA  
*UH2C100A9V5VA  
Not Allowed  
Not Allowed  
Not Allowed  
Not Allowed  
50  
50  
*UH/DH2D120A9V5VA  
NOTES: * - First letter may be "A" or "T"  
1. Minimum vent length for all models: 3' horizontal or 3' vertical.  
2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET (Except adapt-  
ers at the top of the furnace). If different inlet and vent pipe sizes are used, the vent pipe must adhere to the maximum  
length limit shown in the table above (See note 6 below for exception). The inlet pipe can be of a larger diameter, but never  
smaller than the vent pipe.  
3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT IS  
THE MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes).  
4. One SHORT radius 90° elbow is equivalent to 10' of 3" or 4" pipe and one LONG radius elbow is equivalent to 6' of 3" or 4"  
pipe. One 90° elbow is equivalent to 7½' of 2½" pipe or 5' of 2" pipe. Two 45° elbows equal one 90°elbow.  
5. The termination tee or bend must be included in the total number of elbows. If the BAYAIR30AVENTA termination kit is  
used, the equivalent length of pipe is 5 feet. BAYVENT200B equivalent length is 0 feet.  
6. Pipe adapters are field supplied (except for the *UH/DH2D120 models).  
7. For Canadian applications ONLY, IPEX 196006 may be used for horizontal and vertical terminations. IPEX 081216, IPEX  
081218, and IPEX 081219 may only be used for horizontal vent terminations. Equivalent lengths are IPEX 196009 = 5 feet,  
IPEX 081216 = 11 feet, IPEX 081218 = 16 feet, and IPEX 081219 = 21 feet  
20  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical  
Data  
*UH2 WIRING DIAGRAM  
From drawing D344303  
21  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical  
Data  
*UH2 SCHEMATIC DIAGRAM  
From drawing D344303  
22  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical  
Data  
*DH2 WIRING DIAGRAM  
From drawing D344304  
23  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical  
Data  
*DH2 SCHEMATIC DIAGRAM  
From drawing D344304  
24  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Field  
Wiring  
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY  
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING ONLY  
25  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Field  
Wiring  
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING  
(OUTDOOR SECTION WITHOUT TRANSFORMER)  
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING/ SINGLE STAGE COOLING  
(OUTDOOR SECTION WITHOUT TRANSFORMER)  
26  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions  
27  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions  
28  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
29  
Pub. No. 22-1814-08  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trane  
6200 Troup Highway  
Tyler, TX 75707  
Trane has a policy of continuous product and product data improvement and it reserves the right to change  
design and specifications without notice.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Toastmaster Blender RRBL3A User Manual
Toshiba Fax Machine TF 461 User Manual
Toshiba Laptop U400 S1001X User Manual
TRENDnet Network Router Super G Access Point User Manual
Uniden Cordless Telephone DXI665 User Manual
Uniden Telephone DSS8955 User Manual
Video Products Computer Hardware PC HDTV CNVTR User Manual
ViewSonic Computer Monitor VX1932 User Manual
Weber Gas Grill LPG Gas Grill User Manual
Weber Gas Grill Silver C User Manual