Upflow/ Horizontal Left,
Downflow/ Horizontal Right
Variable Speed
Two Stage Condensing
Gas-Fired Furnace
XV 95
TDH2B060A9V3VA
TDH2B080A9V3VA
TDH2B080A9V4VA
TDH2C100A9V4VA
TDH2D120A9V5VA
TUH2B060A9V3VA
TUH2B080A9V3VA
TUH2B080A9V4VA
TUH2C100A9V4VA
TUH2C100A9V5VA
TUH2D120A9V5VA
Direct Vent with
Variable Speed Blower
Variable Speed Inducer
*DH-A9V-V
*UH-A9V-V
DOWNFLOW
UPFLOW
DOWNFLOW/HORIZONTAL
UPFLOW/HORIZONTAL
PUB. NO. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
General Features
Features and Benefits
Standard Equipment
2
4
4
Optional Equipment
5
General Data
TUH2B060A9V3VA
TUH2B080A9V3VA
TUH2B080A9V4VA
TUH2C100A9V4VA
TUH2C100A9V5VA
TUH2D120A9V5VA
TDH2B060A9V3VA
TDH2B080A9V3VA
TDH2B080A9V4VA
TDH2C100A9V4VA
TDH2D120A9V5VA
6-8
Performance Data
Venting Table
Electrical Data
Field Wiring
9-19
20
21-24
25-26
27-28
Dimensions
3
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Features
and Benefits
XV 95 STANDARD EQUIPMENT
• Variable Speed BlowerMotor
• Silicon Nitride Igniter with adaptive
heat up
• Variable speed induced draft blower
• Direct/Non-Direct vent option
• Fused 24 volt control circuit
• Manual reset burner safety switches
• Power supply 115/1/60
• Lite Port™ extended system diag-
nostics
• Stored fault code history in micro pro-
cessor nonvocatile memory
• Cleanable high velocity filters (upflow
only)
• Hinged blower door *
• Perfect fit door latches*
• Insulated blower door*
• Convertible to horizontal on left side
• 2-stage gas valve
• PVC venting-1 or 2 pipe option
• Accessory hook-up capability
• Integrated solid state control with self-
diagnostics
• Attractive color accents
• Heavy gauge aluminized steel heat
exchanger
• Gasketed blower door*
• Complete front service access
• Left/right gas connection
• Adjustable fan off times
• Optional L.P conversion kit
• Selectable cooling fan off delay
eliminates need for BAY24X045
time delay kit
• Multi-port In-shot burners
• Quiet induced draft blower
* (Upflow only)
4
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Features
and Benefits
XV 95 OPTIONAL EQUIPMENT
Thermostat, 2-Stage Heat / 1-Stage Cooling ........................................................................................................... TAYSTAT241 [ ]
Thermostat, Media Programmable 2-Stage Heating..............................................................................................TAYSTAT302C [ ]
Thermostat, Mechanical Heating Only With Fan Switch.........................................................................................TAYSTAT303C [ ]
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) ..............................................................................AY28X092 [ ]
Thermostat, Heating/Cooling Single Stage (Mounts Vertically)................................................................................BAYSTAT305 [ ]
Thermostat, Media Programmable 1-Stage Heating/1-Stage Cooling ...................................................................TAYSTAT300C [ ]
Propane Conversion Kit........................................................................................................................................ BAYLPKT210A [ ]
Media Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace)........................................................... TFM145A9FR0 [ ]
Media Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace)........................................................... TFM175A9FR0 [ ]
Media Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace)................................................................. TFM210A9FR0 [ ]
Media Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace)........................................................... TFM245A9FR0 [ ]
Media Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ....................................................TFP145A9FR0 [ ]
Media Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ....................................................TFP175A9FR0 [ ]
Media Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace)...........................................................TFP210A9FR0 [ ]
Media Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ....................................................TFP245A9FR0 [ ]
Coil Enclosure (14-1/2" Wide Cabinets) .........................................................................................................BAYCLE14A1422A [ ]
Coil Enclosure (17-1/2" Wide Cabinets) .......................................................................................................BAYCLE17A1722A [ ]
Coil Enclosure (21" Wide Cabinets) ..............................................................................................................BAYCLE21A2130A [ ]
Coil Enclosure (24-1/2" Wide Cabinets) .......................................................................................................BAYCLE24A2430A [ ]
Downflow Subbase................................................................................................................................................. BAYBASE205 [ ]
Side Filter Rack ....................................................................................................................................................... BAYFLTR200 [ ]
Filter Kit/Horizontal Conversion TUH2-060,080....................................................................................................... BAYFLTR203 [ ]
Filter Kit/Horizontal Conversion TUH2-100.............................................................................................................. BAYFLTR204 [ ]
Filter Kit/Horizontal Conversion TUH2-120.............................................................................................................. BAYFLTR205 [ ]
High Altitude Pressure Switch Kit TUH2-060 ............................................................................................ BAYSWT10AHALTA1 [ ]
High Altitude Pressure Switch Kit TUH2-080,100,120 .............................................................................. BAYSWT08AHALTA1 [ ]
Concentric Vent Kit TUH2 Furnaces...............................................................................................................BAYAIR30AVENTA [ ]
Sidewall Vent Termination Kit All 2 Pipe Direct Vent Furnaces............................................................................BAYVENT200B [ ]
Manufactured/Mobile Home Kit All 2 Pipe Direct Vent Furnaces........................................................................BAYMFGH100A [ ]
Cleanable Filter (14.5"/17.5" wide Upflow models).................................................................................................. BAYFLTR317 [ ]
Cleanable Filter (21" wide Upflow models).............................................................................................................. BAYFLTR321 [ ]
Cleanable Filter (24.5" wide Upflow models)........................................................................................................... BAYFLTR324 [ ]
CleanEffects™, Whole House Air Cleaner (Upflow 14-1/2" Wide Gas Furnace) ........................................... TFD145ALFR000B [ ]
CleanEffects™, Whole House Air Cleaner (Upflow 17-1/2" Wide Gas Furnace) ...........................................TFD175ALFR000B [ ]
CleanEffects™, Whole House Air Cleaner (Upflow 21" Wide Gas Furnace) ..................................................TFD210ALFR000B [ ]
CleanEffects™, Whole House Air Cleaner (Upflow 24-1/2" Wide Gas Furnace) ...........................................TFD245ALFR000B [ ]
CleanEffects™, Whole House Air Cleaner (Downflow 14-1/2" Wide Gas Furnace) ...................................... TFD14DALFR000B [ ]
CleanEffects™, Whole House Air Cleaner (Downflow 17-1/2" Wide Gas Furnace) ...................................... TFD17DALFR000B [ ]
CleanEffects™, Whole House Air Cleaner (Downflow 21" Wide Gas Furnace) ............................................ TFD21DALFR000B [ ]
CleanEffects™, Whole House Air Cleaner (Downflow 24-1/2" Wide Gas Furnace) ...................................... TFD24DALFR000B [ ]
CleanEffects™, Whole House Transformer Kit (120 to 24 Volt - all TFD Air Cleaners)..................................... BAYTRANS12024 [ ]
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.
5
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
TUH2 PRODUCT SPECIFICATIONS1
1
Product Specifications
TUH2B080A9V3VA
MODEL
TYPE
TUH2B080A9V4VA
TUH2B060A9V3VA
TUH2C100A9V4VA
Upflow/Horizontal
Upflow/Horizontal
Upflow/Horizontal
Upflow/Horizontal
RATINGS
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS) 3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS) 3
AFUE
2
52,000
50,440
80,000
77,600
97
52,000
50,440
80,000
77,600
97
39,000
37,830
60,000
58,200
97
65,000
62,855
100,000
96,700
96.7
Temp. rise (Min.-Max.) °F.
35 - 65
35 - 65
35 - 65
35 - 65
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
DIRECT
10 x 8
1
Variable
DIRECT
11 x 8
1
Variable
DIRECT
10 x 8
1
Variable
DIRECT
10 x 10
1
Variable
See Fan Performance Table
1/2
See Fan Performance Table
3/4
See Fan Performance Table
1/2
See Fan Performance Table
3/4
R.P.M.
Volts/Ph/Hz
Variable
115/1/60
Variable
115/1/60
Variable
115/1/60
Variable
115/1/60
COMBUSTION FAN -Type
Drive - No. Speeds
Motor HP - RPM
Volts/Ph/Hz
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
Ye s
High Velocity
1 - 17x25 - 1 in.
Ye s
High Velocity
1 - 17x25 - 1 in.
Ye s
High Velocity
1 - 17x25 - 1 in.
Ye s
High Velocity
1 - 20x25 - 1 in.
VENT — Size (in.)
2 Round
2 Round
2 Round
3 Round
HEAT EXCHANGER
Type -Fired
-Unfired
Aluminized Steel - Type I
20
Aluminized Steel - Type I
20
Aluminized Steel - Type I
20
Aluminized Steel - Type I
20
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
4 — 45
4 — 56
4 — 45
4 — 56
3 — 45
3 — 56
5 — 45
5 — 56
GAS VALVE
Redundant - Two Stage
Redundant - Two Stage
Redundant - Two Stage
Redundant - Two Stage
PILOT SAFETY DEVICE
Type
Hot Surface Igniter
Hot Surface Igniter
Hot Surface Igniter
Hot Surface Igniter
BURNERS —Type
Number
Multiport Inshot
4
Multiport Inshot
4
Multiport Inshot
3
Multiport Inshot
5
POWER CONN. — V/Ph/Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
115/1/60
11.1
15
115/1/60
13.5
20
115/1/60
11.1
15
115/1/60
13.5
20
PIPE CONN. SIZE (IN.)
1/2
1/2
1/2
1/2
DIMENSIONS
Crated (In.)
H x W x D
41-3/4 x 19-1/2 x 30-1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
H x W x D
41-3/4 x 23 x 30-1/2
WEIGHT
Shipping (Lbs.)/Net (Lbs)
168 / 156
170 / 158
158 / 146
197 / 185
1Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3Based on U.S. government standard tests.
4The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
6
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
TUH2/TDH2 PRODUCT SPECIFICATIONS1
1
PRODUCT SPECIFICATIONS
MODEL
TYPE
TUH2D120A9V5VA
TDH2B060A9V3VA
TDH2B080A9V3VA
TUH2C100A9V5VA
Upflow/Horizontal
Downflow/Horizontal
Downflow/Horizontal
Upflow/Horizontal
RATINGS
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS) 3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS) 3
AFUE
2
78,000
75,426
120,000
116,040
96.7
39,000
37,000
60,000
57,000
95
52,000
49,400
80,000
76,000
95
65,000
62,855
100,000
96,700
96.7
Temp. rise (Min.-Max.) °F.
40 - 70
35 - 65
35 - 65
35 - 65
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
DIRECT
10 x 10
1
Variable
DIRECT
10 x 8
1
Variable
DIRECT
10 x 8
1
Variable
DIRECT
11 x 10
1
Variable
See Fan Performance Table
1
See Fan Performance Table
1/2
See Fan Performance Table
1/2
See Fan Performance Table
1
R.P.M.
Volts/Ph/Hz
Variable
115/1/60
Variable
115/1/60
Variable
115/1/60
Variable
115/1/60
COMBUSTION FAN -Type
Drive - No. Speeds
Motor HP - RPM
Volts/Ph/Hz
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
Ye s
High Velocity
1 - 24x25 - 1 in.
Ye s
High Velocity
2 - 14x20 - 1 in.
Ye s
High Velocity
2 - 14x20 - 1 in.
Ye s
High Velocity
1 - 20x25 - 1 in.
VENT — Size (in.)
3 Round
2 Round
2 Round
3 Round
HEAT EXCHANGER
Type -Fired
-Unfired
Aluminized Steel - Type I
20
Aluminized Steel - Type I
20
Aluminized Steel - Type I
20
Aluminized Steel - Type I
20
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
6 — 45
6 — 56
3 — 45
3 — 56
4 — 45
4 — 56
5 — 45
5 — 56
GAS VALVE
Redundant - Two Stage
Redundant - Two Stage
Redundant - Two Stage
Redundant - Two Stage
PILOT SAFETY DEVICE
Type
Hot Surface Igniter
Hot Surface Igniter
Hot Surface Igniter
Hot Surface Igniter
BURNERS —Type
Number
Multiport Inshot
6
Multiport Inshot
3
Multiport Inshot
4
Multiport Inshot
5
POWER CONN. — V/Ph/Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
115/1/60
15.2
20
115/1/60
11.1
15
115/1/60
11.1
15
115/1/60
16.3
20
PIPE CONN. SIZE (IN.)
1/2
1/2
1/2
1/2
DIMENSIONS
Crated (In.)
H x W x D
41-3/4 x 26-1/2 x 30-1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
H x W x D
41-3/4 x 19-1/2 x 30-1/2
H x W x D
41-3/4 x 23 x 30-1/2
WEIGHT
Shipping (Lbs.)/Net (Lbs)
206 / 193
160/ 146
168 / 158
199 / 187
1Central Furnace heating designs are certified to ANSI Z21.47 / CSA 2.3
2For U.S. applications, above input ratings (BTUH) are up to 2,000 feet, derate 4% per 1,000 feet for elevations above 2,000 feet above sea level. For Canadian
applicaitons, above input ratings (BTUH) are up to 4,500 feet, derate 4% per 1,000 feet for elevations above 4,500 feet above sea level.
3Based on U.S. government standard tests.
4The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
7
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
TDH2 PRODUCT SPECIFICATIONS1
1
PRODUCT SPECIFICATIONS
MODEL
TYPE
TDH2B080A9V4VA
TDH2D120A9V5VA
TDH2C100A9V4VA
Downflow/Horizontal
Downflow/Horizontal
Downflow/Horizontal
RATINGS
1st Stage Input BTUH
1st Stage Capacity BTUH (ICS) 3
2nd Stage Input BTUH
2nd Stage Capacity BTUH (ICS) 3
AFUE
2
52,000
49,400
80,000
76,000
95
78,000
74,000
120,000
114,000
95
65,000
61,750
100,000
95,000
95
Temp. rise (Min.-Max.) °F.
35 - 65
40 - 70
35 - 65
BLOWER DRIVE
Diameter - Width (In.)
No. Used
Speeds (No.)
CFM vs. in. w.g.
Motor HP
DIRECT
11 x 8
1
Variable
DIRECT
10 x 10
1
Variable
DIRECT
10 x 10
1
Variable
See Fan Performance Table
3/4
See Fan Performance Table
1
See Fan Performance Table
3/4
R.P.M.
Volts/Ph/Hz
Variable
115/1/60
Variable
115/1/60
Variable
115/1/60
COMBUSTION FAN -Type
Drive - No. Speeds
Motor HP - RPM
Volts/Ph/Hz
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
Centrifugal
Direct - Variable
1/50 - 5000
33 - 110/3/60 - 180
1.0
FLA
FILTER — Furnished?
Type Recommended
Hi Vel. (No.-Size-Thk.)
Ye s
High Velocity
2 - 14x20 - 1 in.
Ye s
High Velocity
2 - 16x20 - 1 in.
Ye s
High Velocity
2 - 16x20 - 1 in.
VENT — Size (in.)
2 Round
3 Round
3 Round
HEAT EXCHANGER
Type -Fired
-Unfired
Aluminized Steel - Type I
20
Aluminized Steel - Type I
20
Aluminized Steel - Type I
20
Gauge (Fired)
ORIFICES — Main
Nat. Gas. Qty. — Drill Size
L.P. Gas Qty. — Drill Size
4 — 45
4 — 56
6 — 45
6 — 56
5 — 45
5 — 56
GAS VALVE
Redundant - Two Stage
Redundant - Two Stage
Redundant - Two Stage
PILOT SAFETY DEVICE
Type
Hot Surface Igniter
Hot Surface Igniter
Hot Surface Igniter
BURNERS —Type
Number
Multiport Inshot
4
Multiport Inshot
6
Multiport Inshot
5
POWER CONN. — V/Ph/Hz 4
Ampacity (In Amps)
Max. Overcurrent Protection (Amps)
115/1/60
13.5
20
115/1/60
15.2
20
115/1/60
13.5
20
PIPE CONN. SIZE (IN.)
1/2
1/2
1/2
DIMENSIONS
Crated (In.)
H x W x D
41-3/4 x 19-1/2 x 30-1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
H x W x D
41-3/4 x 23 x 30-1/2
WEIGHT
Shipping (Lbs.)/Net (Lbs)
172 / 160
206 / 196
185 / 175
8
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*UH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 37,830
2nd Stage Capacity = 58,200
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
-
CFM
TEMP. RISE
WATTS
600
57
85
600
57
110
600
57
155
600
57
190
LOW
MEDIUM LOW
NORMAL **
HIGH
ON
ON
CFM
TEMP. RISE
WATTS
700
49
90
700
49
130
700
49
175
700
49
210
OFF
ON
ON
OFF
OFF
ON
-
-
-
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
775
44
105
775
44
155
775
44
195
775
44
240
CFM
TEMP. RISE
WATTS
870
39
135
870
39
185
870
39
235
870
39
290
OFF
ON
CFM
TEMP. RISE
WATTS
860
61
140
920
57
200
920
57
245
920
57
300
670
79
245
LOW
CFM
TEMP. RISE
WATTS
1000
53
190
1000
53
255
1000
53
305
1000
53
340
700
75
255
MEDIUM LOW
NORMAL **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
1125
47
250
1125
47
315
1125
47
370
1025
51
355
775
68
285
OFF
OFF
CFM
TEMP. RISE
WATTS
1250
42
340
1250
42
405
1250
42
445
1100
48
390
1000
53
355
OFF
NOTES: * First letter may be "A" or "T"
** Factory setting
*UH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 1
ON
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
-
LOW
(350 CFM/TON)
CFM
WATTS
575
65
575
90
575
125
550
155
NORMAL
(400 CFM/TON)
CFM
WATTS
640
70
640
110
640
140
630
175
1.5
2.0
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
-
-
-
-
-
-
HIGH
(450 CFM/TON)
CFM
WATTS
700
85
700
125
700
160
700
200
LOW
(350 CFM/TON)
CFM
WATTS
700
100
700
130
700
170
700
210
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
800
115
800
155
800
200
800
250
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
900
140
900
195
900
240
900
290
ON
LOW
(350 CFM/TON)
CFM
WATTS
875
130
875
180
875
230
875
270
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1000
175
1000
235
1000
285
1000
335
900
310
2.5
3
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1125
235
1125
295
1125
345
1100
370
925
318
ON
LOW
(350 CFM/TON)
CFM
WATTS
1050
195
1050
260
1050
305
1050
350
920
315
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1200
275
1200
330
1200
385
1100
385
940
330
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1325
360
1325
425
1300
460
1175
425
1000
365
NOTES: * First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
9
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*UH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 50,440
2nd Stage Capacity = 77,600
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
800
56
105
800
56
140
800
56
180
800
56
220
800
56
265
LOW
ON
ON
CFM
TEMP. RISE
WATTS
860
52
115
880
51
165
890
50
215
920
48
265
910
49
320
MEDIUM LOW
OFF
ON
ON
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
960
46
150
990
45
200
1000
44
230
1020
44
310
1010
44
350
NORMAL **
OFF
CFM
TEMP. RISE
WATTS
1080
41
195
1110
40
255
1120
40
315
1120
40
365
1080
41
390
HIGH
LOW
OFF
ON
OFF
ON
CFM
TEMP. RISE
WATTS
1100
62
205
1100
62
260
1120
61
320
1120
61
370
1090
63
400
CFM
TEMP. RISE
WATTS
1210
57
265
1240
55
340
1260
54
410
1260
54
470
1130
61
430
MEDIUM LOW
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
1360
50
365
1390
49
445
1400
49
500
1360
50
535
1210
57
475
NORMAL **
OFF
CFM
TEMP. RISE
WATTS
1360
50
355
1390
49
450
1400
49
520
1350
51
535
1180
58
465
HIGH
OFF
OFF
NOTES: * First letter may be "A" or "T"
** Factory setting
*UH2B080A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
OUTDOOR
UNIT SIZE
(TONS)
AIRFLOW
SETTING
SW 1
ON
SW 2
ON
SW 3
OFF
OFF
ON
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
LOW
(350 CFM/TON)
NORMAL
(400 CFM/TON)
HIGH
(450 CFM/TON)
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
CFM
WATTS
750
84
840
109
940
136
850
113
960
150
1080
195
1020
175
1170
240
1290
310
1170
250
1360
365
1360
355
750
122
750
154
720
185
710
221
820
264
940
318
890
295
1010
350
1080
390
1050
375
1130
420
1150
440
1100
405
1210
475
1180
460
840
146
840
181
840
226
2.0
2.5
3.0
3.5
ON
ON
OFF
OFF
ON
940
177
940
215
940
274
ON
ON
850
150
870
200
890
250
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
990
200
1000
230
1020
305
ON
OFF
OFF
ON
1110
255
1120
315
1120
365
ON
1020
225
1040
280
1050
330
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
1180
300
1200
365
1200
415
ON
OFF
OFF
ON
1320
410
1350
470
1340
520
ON
1190
315
1210
370
1210
435
OFF
OFF
OFF
OFF
OFF
ON
1390
445
1400
500
1360
535
OFF
OFF
1390
450
1400
520
1350
535
NOTES: * First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
10
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*UH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 50,440
2nd Stage Capacity = 77,600
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
800
56
105
800
56
140
800
56
180
800
56
220
800
56
265
LOW
MEDIUM LOW
NORMAL **
HIGH
ON
ON
CFM
TEMP. RISE
WATTS
860
52
115
880
51
165
890
50
215
920
48
265
910
49
320
OFF
ON
ON
OFF
OFF
ON
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
960
46
150
990
45
200
1000
44
230
1020
44
310
1010
44
350
CFM
TEMP. RISE
WATTS
1080
41
195
1110
40
255
1120
40
315
1120
40
365
1080
41
390
OFF
ON
CFM
TEMP. RISE
WATTS
1100
62
205
1100
62
260
1120
61
320
1120
61
370
1090
63
400
LOW
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
1210
57
265
1240
55
340
1260
54
410
1260
54
470
1130
61
430
MEDIUM LOW
NORMAL **
HIGH
OFF
ON
ON
CFM
TEMP. RISE
WATTS
1360
50
365
1390
49
445
1400
49
500
1360
50
535
1210
57
475
OFF
OFF
CFM
TEMP. RISE
WATTS
1360
50
355
1390
49
450
1400
49
520
1350
51
535
1180
58
465
OFF
NOTES: * First letter may be "A" or "T"
** Factory setting
*UH2B080A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 1
ON
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
857
107
849
143
841
179
833
223
825
266
NORMAL
(400 CFM/TON)
CFM
WATTS
970
158
971
205
973
251
966
298
960
345
2.5
3.0
3.5
4.0
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1082
209
1093
266
1104
323
1099
374
1095
424
LOW
(350 CFM/TON)
CFM
WATTS
1004
153
1019
210
1035
267
1038
321
1041
374
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1163
249
1173
311
1184
372
1179
426
1174
480
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1323
345
1328
411
1332
477
1320
532
1307
586
ON
LOW
(350 CFM/TON)
CFM
WATTS
1176
254
1188
317
1200
380
1195
437
1190
494
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1356
379
1362
446
1368
514
1353
568
1339
623
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1536
503
1536
575
1536
647
1512
699
1488
751
ON
LOW
(350 CFM/TON)
CFM
WATTS
1376
374
1367
429
1359
483
1354
547
1348
611
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1562
530
1562
604
1563
677
1531
720
1499
765
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1768
757
1759
830
1749
902
1654
866
1559
829
NOTES: * First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
11
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*UH2C100A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 62,855
2nd Stage Capacity = 96,700
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW8
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
873
64
100
971
58
115
1136
49
160
1258
44
225
893
63
145
997
56
170
1146
49
230
1298
43
300
900
62
195
1006
56
220
1165
48
295
1319
42
390
899
62
240
1022
55
280
1180
47
365
1328
42
450
902
62
290
1029
54
335
1184
47
425
1286
44
490
LOW
MEDIUM LOW
MEDIUM **
HIGH
ON
ON
OFF
ON
ON
OFF
OFF
ON
HEATING
1ST
STAGE
OFF
ON
CFM
TEMP. RISE
WATTS
1260
68
213
1304
66
305
1329
65
380
1334
65
460
1317
65
510
LOW
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
1464
59
315
1631
53
450
1846
47
640
1471
59
405
1678
51
570
1867
46
760
1478
58
485
1690
51
670
1794
48
770
1478
58
560
1579
55
645
1644
52
700
1350
64
540
1419
61
585
1498
57
650
MEDIUM LOW
MEDIUM **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
OFF
OFF
OFF
NOTES: * First letter may be "A" or "T"
** Factory setting
*UH2C100A9V4V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
OUTDOOR
UNIT SIZE
(TONS)
AIRFLOW
SETTING
0.1
0.3
0.5
0.7
0.9
SW 1
ON
SW 2
ON
SW 3
OFF
OFF
ON
SW 4
ON
LOW
(350 CFM/TON)
CFM
WATTS
808
75
824
125
840
170
835
210
830
250
NORMAL
(400 CFM/TON)
CFM
WATTS
938
100
963
160
959
205
964
255
975
310
2.5
3.0
3.5
4.0
ON
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1058
150
1100
200
1121
265
1136
330
1142
395
ON
ON
LOW
(350 CFM/TON)
CFM
WATTS
1004
120
1010
175
1027
230
1044
285
1050
345
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1141
170
1190
245
1214
310
1229
380
1234
450
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1336
250
1375
330
1387
410
1388
480
1384
545
ON
LOW
(350 CFM/TON)
CFM
WATTS
1153
180
1206
250
1230
320
1239
395
1244
460
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1390
285
1418
465
1439
445
1441
515
1373
540
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1575
400
1606
495
1632
590
1596
645
1445
590
ON
LOW
(350 CFM/TON)
CFM
WATTS
1388
290
1423
360
1444
440
1444
515
1390
540
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1610
415
1641
515
1666
635
1607
650
1449
595
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1847
630
1863
735
1816
780
1687
720
1532
665
NOTES: *First letter may be "A" or "T"
1. At Continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
12
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*UH2C100A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 62,855
2nd Stage Capacity = 96,700
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
873
64
100
893
63
145
900
62
195
899
62
240
902
62
290
LOW
MEDIUM LOW
MEDIUM **
HIGH
ON
ON
CFM
TEMP. RISE
WATTS
971
58
115
997
56
170
1006
56
220
1022
55
280
1029
54
335
OFF
ON
ON
OFF
OFF
ON
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
1136
49
160
1146
49
230
1165
48
295
1180
47
365
1184
47
425
CFM
TEMP. RISE
WATTS
1258
44
225
1298
43
300
1319
42
390
1328
42
450
1286
44
490
OFF
ON
CFM
TEMP. RISE
WATTS
1260
68
213
1304
66
305
1329
65
380
1334
65
460
1317
65
510
LOW
CFM
TEMP. RISE
WATTS
1464
59
315
1471
59
405
1478
58
485
1478
58
560
1350
64
540
MEDIUM LOW
MEDIUM **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
1631
53
450
1678
51
570
1690
51
670
1579
55
645
1419
61
585
OFF
OFF
CFM
TEMP. RISE
WATTS
1846
47
640
1867
46
760
1794
48
770
1644
52
700
1498
57
650
OFF
NOTES:
* First letter may be "A" or "T"
** Factory setting
*UH2C100A9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 1
OFF
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
1163
222
1201
304
1209
375
1200
433
1199
495
NORMAL
(400 CFM/TON)
CFM
WATTS
1339
331
1365
400
1366
477
1377
555
1382
636
3.5
4.0
5.0
OFF
OFF
ON
ON
OFF
ON
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1515
440
1538
535
1549
620
1553
708
1547
796
LOW
(350 CFM/TON)
CFM
WATTS
1339
331
1365
400
1366
477
1377
555
1382
636
ON
ON
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1550
471
1562
550
1574
645
1575
733
1564
813
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1744
626
1758
736
1770
838
1772
935
1760
1018
ON
OFF
OFF
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
LOW
(350 CFM/TON)
CFM
WATTS
1695
578
1709
728
1721
820
1772
930
1711
1007
OFF
OFF
OFF
NORMAL
(400 CFM/TON)
CFM
WATTS
1919
862
1919
958
1905
1043
1831
1043
1709
982
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
NA
NA
NA
NA
NA
NA
NA
NA
NA
NA
NOTES: *First letter may be "A" or "T"
1. At Continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
3. NA = Not allowed.
13
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*UH2D120A9V5V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st Stage Capacity = 75,426
2nd Stage Capacity = 116,040
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
1090
62
165
1120
60
225
1080
63
270
1070
63
310
1010
67
380
LOW
MEDIUM LOW
NORMAL **
HIGH
ON
ON
CFM
TEMP. RISE
WATTS
1210
56
220
1200
56
280
1200
56
330
1180
57
395
1160
58
455
OFF
ON
ON
OFF
OFF
ON
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
1340
50
295
1360
50
350
1370
49
425
1380
49
495
1330
51
535
CFM
TEMP. RISE
WATTS
1430
47
390
1570
43
490
1580
43
565
1570
43
625
1390
49
565
OFF
ON
CFM
TEMP. RISE
WATTS
1660
63
485
1690
62
590
1680
62
640
1640
64
675
1460
72
600
LOW
CFM
TEMP. RISE
WATTS
1870
56
675
1870
56
745
1810
58
770
1680
62
715
1490
70
625
MEDIUM LOW
NORMAL **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
2060
51
880
1990
53
890
1850
57
810
1710
61
750
1530
68
665
OFF
OFF
CFM
TEMP. RISE
WATTS
2200
48
1030
2090
50
965
1940
54
895
1790
58
830
1640
64
750
OFF
NOTES:
* First letter may be "A" or "T"
** Factory setting
*UH2D120A9V5V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 1
OFF
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
1210
220
1210
270
1220
325
1230
400
1230
445
NORMAL
(400 CFM/TON)
CFM
WATTS
1400
305
1440
390
1450
465
1450
510
1410
560
3.5
4.0
5
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1590
425
1600
520
1610
600
1600
645
1380
575
LOW
(350 CFM/TON)
CFM
WATTS
1390
305
1400
375
1430
445
1440
515
1420
565
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1620
420
1650
530
1670
595
1640
660
1480
600
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1840
600
1830
690
1820
765
1670
700
1490
620
ON
LOW
(350 CFM/TON)
CFM
WATTS
1800
570
1780
630
1780
705
1700
695
1530
615
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
2050
845
2010
875
1860
805
1710
735
1530
655
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
2160
995
2040
935
1920
875
1780
805
1620
730
NOTES: * First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
14
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*DH2B060A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st STAGE CAPACITY = 37,440
2nd STAGE CAPACITY = 57,600
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
600
56
55
600
56
85
600
56
120
600
56
150
600
56
185
LOW
MEDIUM LOW
NORMAL **
HIGH
ON
ON
CFM
TEMP. RISE
WATTS
675
50
65
675
50
105
675
50
140
675
50
175
675
50
205
OFF
ON
ON
OFF
OFF
ON
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
750
45
85
750
45
125
750
45
160
750
45
210
750
45
260
CFM
TEMP. RISE
WATTS
850
40
115
850
40
155
850
40
205
850
40
260
850
40
320
OFF
ON
CFM
TEMP. RISE
WATTS
900
58
125
900
58
165
900
58
220
900
58
270
900
58
315
LOW
CFM
TEMP. RISE
WATTS
1000
52
170
1050
50
230
1050
50
295
1050
50
335
1050
50
370
MEDIUM LOW
NORMAL **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
1100
47
215
1150
45
285
1150
45
340
1150
45
395
1100
47
440
OFF
OFF
CFM
TEMP. RISE
WATTS
1300
40
330
1325
39
385
1325
39
455
1250
42
465
1200
43
470
OFF
NOTES:
* First letter may be "A" or "T"
** Factory setting
*DH2B060A9V3V FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 1
OFF
SW 2
OFF
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
525
45
525
70
525
100
525
135
525
160
NORMAL
(400 CFM/TON)
CFM
WATTS
600
55
600
85
600
120
600
150
600
185
1.5
2.0
2.5
3
OFF
OFF
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
675
65
675
105
625
140
675
175
675
205
LOW
(350 CFM/TON)
CFM
WATTS
700
70
700
115
700
145
700
185
700
220
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
800
100
800
135
800
175
800
225
800
280
ON
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
900
125
900
165
900
220
900
270
900
330
ON
ON
LOW
(350 CFM/TON)
CFM
WATTS
875
115
875
160
875
210
875
260
875
310
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1000
150
1000
207
1000
265
1000
320
1000
380
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1125
215
1125
285
1125
340
1125
395
1125
440
ON
LOW
(350 CFM/TON)
CFM
WATTS
1050
175
1050
240
1050
305
1050
345
1050
380
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1200
240
1200
315
1200
385
1200
440
1100
410
ON
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1350
330
1350
410
1350
500
1275
485
1170
450
ON
NOTES: * First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
15
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*DH2B080A9V3V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st STAGE CAPACITY = 49,920
2nd STAGE CAPACITY = 76,800
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
-
CFM
TEMP. RISE
WATTS
800
56
130
800
56
170
800
56
210
790
56
245
LOW
MEDIUM LOW
NORMAL **
HIGH
ON
ON
CFM
TEMP. RISE
WATTS
900
49
162
900
49
210
900
49
260
900
49
295
OFF
ON
ON
OFF
OFF
ON
-
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
1000
44
205
1000
44
265
1000
44
310
1000
44
345
800
56
295
CFM
TEMP. RISE
WATTS
1170
38
305
1170
38
350
1170
38
400
1020
44
360
830
54
310
OFF
ON
CFM
TEMP. RISE
WATTS
1150
60
285
1150
60
345
1150
60
385
1020
67***
360
830
83***
305
LOW
CFM
TEMP. RISE
WATTS
1275
54
380
1275
54
445
1200
57
425
1040
66***
380
900
76***
350
MEDIUM LOW
NORMAL **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
1430
48
515
1340
51
490
1220
56
455
1090
63
410
930
74***
380
OFF
OFF
CFM
TEMP. RISE
WATTS
1430
48
515
1340
51
490
1220
56
455
1090
63
410
930
74***
380
OFF
NOTES: * - First letter may be "A" or "T"
** Factory setting
*** Above MAX Temperature change value
*DH2B080A9V3V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 1
ON
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
700
95
700
105
700
115
680
200
670
235
NORMAL
(400 CFM/TON)
CFM
WATTS
800
130
800
160
800
205
790
245
740
265
2.0
2.5
3.0
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
900
160
900
215
900
255
900
300
750
270
LOW
(350 CFM/TON)
CFM
WATTS
875
145
875
185
875
240
875
280
760
270
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1000
205
1000
265
1000
310
1000
340
800
295
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1150
295
1150
340
1150
385
1020
350
800
300
ON
LOW
(350 CFM/TON)
CFM
WATTS
1050
235
1050
295
1050
340
1010
350
800
290
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1200
335
1200
385
1200
410
1040
365
840
310
ON
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1350
455
1350
480
1210
435
1070
390
900
345
ON
NOTES: * First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
16
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*DH2B080A9V4V FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st STAGE CAPACITY = 49,400
2nd STAGE CAPACITY = 76,000
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
-
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
800
56
130
900
49
162
1000
44
205
1170
38
305
800
56
170
900
49
210
1000
44
265
1170
38
350
800
56
210
900
49
260
1000
44
310
1170
38
400
790
56
245
900
49
295
1000
44
345
1020
44
360
LOW
MEDIUM LOW
MEDIUM **
HIGH
ON
ON
OFF
ON
ON
OFF
OFF
ON
-
HEATING
1ST
STAGE
800
56
295
830
54
310
830
83***
305
OFF
ON
CFM
TEMP. RISE
WATTS
1150
60
285
1150
60
345
1150
60
385
1020
67***
360
LOW
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
1275
54
380
1430
48
515
1430
48
515
1275
54
445
1340
51
490
1340
51
490
1200
57
425
1220
56
455
1220
56
455
1040
66***
380
1090
63
410
1090
63
900
76***
350
930
74***
380
930
74***
380
MEDIUM LOW
MEDIUM **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
OFF
OFF
OFF
410
NOTES: * - First letter may be "A" or "T"
** Factory setting
*** Above MAX Temperature change value
*DH2B080A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 1
ON
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
849
141
865
191
881
241
878
294
876
348
NORMAL
(400 CFM/TON)
CFM
WATTS
953
195
965
250
977
305
973
358
970
411
2.5
3.0
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1057
249
1065
309
1073
369
1069
422
1064
474
LOW
(350 CFM/TON)
CFM
WATTS
999
188
1003
241
1008
394
1018
354
1029
414
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1144
300
1150
362
1156
423
1160
486
1165
548
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1288
412
1297
482
1305
552
1303
617
1300
682
ON
LOW
(350 CFM/TON)
CFM
WATTS
1156
307
1165
374
1174
440
1177
502
1179
563
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1327
446
1335
518
1343
589
1325
641
1307
693
3.5
4.0
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1506
634
1502
703
1498
771
1418
746
1338
721
ON
LOW
(350 CFM/TON)
CFM
WATTS
1327
446
1335
518
1343
589
1325
641
1307
693
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1525
656
1522
727
1518
797
1430
761
1341
725
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1706
906
1635
881
1563
857
1471
813
1379
769
NOTES: * First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
17
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*DH2C100A9V4V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st STAGE CAPACITY = 62,400
2nd STAGE CAPACITY = 96,000
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 7
SW 8
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
923
61
110
1020
55
145
1156
48
185
1275
44
225
955
59
165
1047
53
190
1166
48
240
1305
43
290
960
58
210
1053
53
250
1172
48
300
1328
42
365
958
58
265
1042
54
295
1177
48
350
1328
42
445
947
59
310
1029
54
350
1178
48
420
1328
42
510
LOW
MEDIUM LOW
MEDIUM **
HIGH
ON
ON
OFF
ON
ON
OFF
OFF
ON
HEATING
1ST
STAGE
OFF
ON
CFM
TEMP. RISE
WATTS
1298
66
235
1320
65
305
1335
65
380
1343
64
445
1343
64
520
LOW
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
CFM
TEMP. RISE
WATTS
1439
60
310
1639
53
430
1790
18
570
1459
59
390
1650
52
525
1818
47
670
1482
58
470
1650
52
600
1813
47
770
1483
58
550
1644
52
680
1708
50
750
1470
59
610
1496
58
640
1535
56
675
MEDIUM LOW
MEDIUM **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
OFF
OFF
OFF
NOTES: * - First letter may be "A" or "T"
** Factory setting
*** Above MAX temperature change
*DH2C100A9V4V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 1
ON
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
870
100
885
140
887
185
881
230
876
270
NORMAL
(400 CFM/TON)
CFM
WATTS
989
120
1018
180
1016
230
1012
285
999
325
2.5
3.0
ON
ON
ON
ON
OFF
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1124
175
1139
225
1130
275
1135
335
1135
390
LOW
(350 CFM/TON)
CFM
WATTS
1053
145
1075
200
1070
245
1070
295
1049
350
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1186
195
1205
255
1220
310
1220
370
1216
440
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1336
255
1366
340
1383
405
1385
470
1381
545
ON
LOW
(350 CFM/TON)
CFM
WATTS
1216
190
1225
255
1235
320
1240
385
1243
445
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1394
270
1422
360
1436
430
1437
505
1430
580
3.5
4.0
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1579
395
1604
475
1610
555
1599
645
1517
640
ON
LOW
(350 CFM/TON)
CFM
WATTS
1377
270
1412
355
1426
430
1433
510
1428
575
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1599
425
1624
510
1636
585
1618
670
1512
635
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
1801
580
1818
690
1815
775
1694
735
1525
660
NOTES: * - First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
18
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
*DH2D120A9V5V - FURNACE HEATING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
1st STAGE CAPACITY = 74,880
2nd STAGE CAPACITY = 115,200
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 8
SW 7
0.1
0.3
0.5
0.7
0.9
CFM
TEMP. RISE
WATTS
1025
65
150
1025
65
200
1000
67
240
1000
67
290
1000
67
340
LOW
ON
ON
CFM
TEMP. RISE
WATTS
1200
56
230
1200
56
270
1200
56
330
1200
56
390
1200
56
450
MEDIUM LOW
OFF
ON
ON
OFF
OFF
ON
HEATING
1ST
STAGE
CFM
TEMP. RISE
WATTS
1350
49
280
1350
49
340
1350
49
490
1350
49
470
1350
49
530
NORMAL **
HIGH
CFM
TEMP. RISE
WATTS
1550
43
400
1550
43
490
1550
43
560
1550
43
620
1450
46
600
OFF
ON
CFM
TEMP. RISE
WATTS
1550
66
380
1550
66
470
1550
66
540
1550
66
610
1450
71***
690
LOW
CFM
TEMP. RISE
WATTS
1850
56
660
1850
56
750
1850
56
780
1700
60
720
1500
69
640
MEDIUM LOW
NORMAL **
HIGH
OFF
ON
ON
HEATING
2ND
STAGE
CFM
TEMP. RISE
WATTS
2050
50
860
2000
51
880
1850
56
810
1700
60
750
1550
66
670
OFF
OFF
CFM
TEMP. RISE
WATTS
2105
49
1000
2050
50
940
1900
54
880
1775
58
820
1625
63
750
OFF
NOTES:
* First letter may be "A" or "T"
** Factory setting
*DH2D120A9V5V - FURNACE COOLING AIRFLOW (CFM) AND POWER (WATTS) VS. EXTERNAL STATIC PRESSURE WITH FILTER
OUTDOOR
UNIT SIZE
(TONS)
DIP SWITCH SETTING
EXTERNAL STATIC PRESSURE
AIRFLOW
SETTING
SW 1
OFF
SW 2
ON
SW 3
OFF
SW 4
ON
0.1
0.3
0.5
0.7
0.9
LOW
(350 CFM/TON)
CFM
WATTS
1225
240
1225
280
1225
340
1225
400
1225
450
NORMAL
(400 CFM/TON)
CFM
WATTS
1400
310
1400
390
1400
470
1400
520
1400
570
3.5
4.0
5
OFF
OFF
ON
ON
ON
OFF
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1600
450
1600
520
1600
590
1600
640
1450
600
LOW
(350 CFM/TON)
CFM
WATTS
1400
300
1400
380
1400
450
1400
520
1400
570
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
1600
460
1600
530
1600
610
1600
670
1450
600
ON
OFF
OFF
ON
HIGH
(450 CFM/TON)
CFM
WATTS
1800
610
1800
700
1800
760
1650
690
1500
630
ON
LOW
(350 CFM/TON)
CFM
WATTS
1750
580
1750
640
1750
720
1650
680
1450
610
OFF
OFF
OFF
OFF
OFF
ON
NORMAL
(400 CFM/TON)
CFM
WATTS
2000
830
2000
860
1850
800
1700
740
1550
660
OFF
OFF
HIGH
(450 CFM/TON)
CFM
WATTS
2100
970
2000
910
1900
850
1650
780
1600
710
NOTES: * - First letter may be "A" or "T"
1. At continuous fan setting: Heating or Cooling airflows are approximately 50% of selected cooling value.
2. LOW airflow (350 cfm/ton) is COMFORT & HUMID CLIMATE setting;
NORMAL airflow (400 cfm/ton) is typical setting;
HIGH airflow (450 cfm/ton) is DRY CLIMATE setting.
19
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Maximum Vent
Length Table
VENT LENGTH TABLE
ALTITUDE
MAXIMUM TOTAL EQUIVALENT LENGTH IN FEET
FOR VENT AND INLET AIR (SEE NOTES)
0-7,000 Feet
2 INCH PIPE
200
2.5 INCH PIPE
200
3 or 4 INCH PIPE
200
*UH/DH2B060A9V3VA
*UH/DH2B080A9V3VA
*UH/DH2B080A9V4VA
50
120
60
200
200
*UH/DH2C100A9V4VA
*UH2C100A9V5VA
Not Allowed
*UH/DH2D120A9V5VA
7,000-9,500 Feet
Not Allowed
2 INCH PIPE
100
Not Allowed
2.5 INCH PIPE
100
200
3 or 4 INCH PIPE
100
*UH/DH2B060A9V3VA
*UH/DH2B080A9V3VA
*UH/DH2B080A9V4VA
25
60
30
100
100
*UH/DH2C100A9V4VA
*UH2C100A9V5VA
Not Allowed
*UH/DH2D120A9V5VA
9,500-12,000 Feet
Not Allowed
2 INCH PIPE
50
Not Allowed
2.5 INCH PIPE
50
100
3 or 4 INCH PIPE
50
*UH/DH2B060A9V3VA
*UH/DH2B080A9V3VA
*UH/DH2B080A9V4VA
Not Allowed
30
50
*UH/DH2C100A9V4VA
*UH2C100A9V5VA
Not Allowed
Not Allowed
Not Allowed
Not Allowed
50
50
*UH/DH2D120A9V5VA
NOTES: * - First letter may be "A" or "T"
1. Minimum vent length for all models: 3' horizontal or 3' vertical.
2. DO NOT MIX PIPE DIAMETERS IN THE SAME LENGTH OF PIPE OUTSIDE THE FURNACE CABINET (Except adapt-
ers at the top of the furnace). If different inlet and vent pipe sizes are used, the vent pipe must adhere to the maximum
length limit shown in the table above (See note 6 below for exception). The inlet pipe can be of a larger diameter, but never
smaller than the vent pipe.
3. MAXIMUM PIPE LENGTHS MUST NOT BE EXCEEDED! THE LENGTH SHOWN IS NOT A COMBINED TOTAL, IT IS
THE MAXIMUM LENGTH OF EACH (Vent or Inlet air pipes).
4. One SHORT radius 90° elbow is equivalent to 10' of 3" or 4" pipe and one LONG radius elbow is equivalent to 6' of 3" or 4"
pipe. One 90° elbow is equivalent to 7½' of 2½" pipe or 5' of 2" pipe. Two 45° elbows equal one 90°elbow.
5. The termination tee or bend must be included in the total number of elbows. If the BAYAIR30AVENTA termination kit is
used, the equivalent length of pipe is 5 feet. BAYVENT200B equivalent length is 0 feet.
6. Pipe adapters are field supplied (except for the *UH/DH2D120 models).
7. For Canadian applications ONLY, IPEX 196006 may be used for horizontal and vertical terminations. IPEX 081216, IPEX
081218, and IPEX 081219 may only be used for horizontal vent terminations. Equivalent lengths are IPEX 196009 = 5 feet,
IPEX 081216 = 11 feet, IPEX 081218 = 16 feet, and IPEX 081219 = 21 feet
20
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
*UH2 WIRING DIAGRAM
From drawing D344303
21
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
*UH2 SCHEMATIC DIAGRAM
From drawing D344303
22
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
*DH2 WIRING DIAGRAM
From drawing D344304
23
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
*DH2 SCHEMATIC DIAGRAM
From drawing D344304
24
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Field
Wiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING ONLY
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING ONLY
25
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Field
Wiring
FIELD WIRING DIAGRAM FOR SINGLE STAGE HEATING/COOLING
(OUTDOOR SECTION WITHOUT TRANSFORMER)
FIELD WIRING DIAGRAM FOR TWO STAGE HEATING/ SINGLE STAGE COOLING
(OUTDOOR SECTION WITHOUT TRANSFORMER)
26
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
27
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
28
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Notes
29
Pub. No. 22-1814-08
Download from Www.Somanuals.com. All Manuals Search And Download.
Trane
6200 Troup Highway
Tyler, TX 75707
Trane has a policy of continuous product and product data improvement and it reserves the right to change