Packaged Cooling with
Electric Heat Rooftop Units
Precedent ™
3 - 10Tons — 60 Hz
RT-PRC005-EN
March 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
Introduction
2
4
8
Features and Benefits
Application Considerations
Selection Procedure
Model Number Description
General Data
9
10
11
Performance Data
15
Cooling Performance
Fan Performance
Heat Performance
15
26
47
Controls
49
50
64
73
Electric Power
Dimension andWeights
Mechanical Specifications
RT-PRC005-EN
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Features and
Benefits
Easy Access Panels
Remove two screws for access to the
standardized internal components and
wiring.
Easy-Adjust Idler Arm
With the Easy-Adjust Idler Arm, the belt
and sheaves on belt drive units can be
quickly adjusted without moving the
mounted fan motor.The result is a major
savings in time and money.
Patented Condenser Coil
Precedent boasts a patented 1+1+1
Hybrid coil, permanently gapped for
easy of cleaning.
Unit Cabinet
The compact cabinet with rounded
corners takes up less room and is less
costly to ship. The beveled and ribbed
top is not only aesthetically pleasing, it is
designed to prevent water from pooling.
Single Point Power
ColoredAnd NumberedWiring
A single electrical connection powers the
unit.
You save time and money tracing wires
and diagnosing the unit.
Convertible Units
Sloped Drain Pans
• The units ship in a downflow
configuration.They can be easily
converted to horizontal by simply
moving two panels.
Every Precedent unit has a non-
corrosive, removable, double-sloped
drain pan that’s easy to clean and
reversible to allow installation of drain
trap on either side of the unit.
• Units come complete with horizontal
duct flanges so the contractor doesn’t
have to field fabricate them.These
duct flanges are a time and cost saver.
Compressors
Through the Base Condensate
Precedent™ contains the best
compressor technology available to
achieve the highest possible
performance. Our compressor line
includesTrane built reciprocating and
scrolls.
Every unit includes provisions for
through the base condensate drain
connections. This allows the drain to be
connected through the roof curb instead
of a roof penetration.
Foil-Faced Insulation
Easy Access Panels
All panels in the Evaporator section of
the unit have cleanable foil-faced
insulation. All edges are either captured
or sealed to ensure no fibers get into the
airstream.
Easy access panels reduce the number of
possible water entry points.
LowAmbient Cooling
All Precedent microprocessor units have
cooling capabilities down to 0°F as
standard. Electromechanical models
have cooling capabilities to 40°F as built,
or to 0°F by adding the optional low
ambient control (frostat).
Unit Base
For added water integrity, Precedent has
a raised 11/ " lip around the unit’s
downflow 8supply and return to prevent
water from blowing into the ductwork.
RT-PRC005-EN
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Features and
Benefits
Standardized Components
• Requires no special tools to run the
Precedent unit through its paces during
testing. Simply place a jumper between
Test 1 andTest 2 terminals on the Low
VoltageTerminal Board and the unit will
walk through its operational steps.The
unit automatically returns control to the
zone sensor after stepping through the
test mode a single time, even if the
jumper is left on the unit.
• Components are placed in the same
location on all Precedent™ units.
Familiarize yourself with one Precedent
and you are familiar with every
Precedent.
• As long as the unit has power and the
LED is lit, the Micro is operational.The
light indicates that the Micro is
functioning properly.
Micro Controls
Several years ago,Trane was the first to
introduce microprocessor controls into
the Light Commercial Market.That
design, along with immeasurable
experience, has provided the technology
forTrane’s second-generation ReliaTel™
microprocessor controls.
• Features expanded diagnostic
capabilities when used withTrane’s
Integrated ComfortTM Systems.
• As an energy benefit, softens electrical
‘’spikes’’ by staging on fans,
compressors and heaters.
Easy Access LowVoltageTerminal Board
Precedent’s LowVoltageTerminal Board
is external to the electrical control
cabinet. It is extremely easy to locate and
attach the thermostat wire.This is
another cost and time saving installation
feature.
ReliaTel™ Micro:
• The Intelligent Fallback or Adaptive
Control is a benefit to the building
occupant. If a component goes astray,
the unit will continue to operate at
predetermined temperature set points.
• Provides unit control for heating,
cooling, and ventilating by utilizing input
from sensors that measure outdoor
and indoor temperature.
LowVoltage Connections
• Intelligent Anticipation is a standard
feature of the Micro. Functioning
constantly, the Micro and zone sensors
work together in harmony, to provide
tight comfort control.
• Improves quality and reliability through
the use of time-tested microprocessor
controls and logic.
The wiring of the low voltage connections
to the unit and the zone sensors is as
simple as 1-1, 2-2, and 3-3.This simplified
system makes it easy for the installer to
wire
• Prevents the unit from short cycling,
considerably improving compressor
life.
Electromechanical Controls
Single-Side Service
• For the simpler job that does not
require a building automation system,
or expanded diagnostics capabilities,
Precedent offers electromechnical
controls. This 24-volt control includes
the control transformer, contactor
pressure lugs for power wiring.
• Ensures that the compressor will run for
a specific amount of time, which allows
oil to return for better lubrication,
enhancing the reliability of the
compressor.
Single-side service is standard on all
Precedent units.
FlexibleApplications
• Only two roof curbs for the 3-10 ton
Precedent line. . .simplifies curb
• Reduces the number of components
required to operate the unit, thereby
reducing possibilities for component
failure.
• sSetalencdtiaornd.or High Efficiency Cooling
• Electromechanical or ReliaTel
microprocessor controls to meet either
the simple or the more complex
application.
• Airflow is outstanding.The Precedent
can replace an older machine with old
ductwork and, in many cases, improve
comfort through better air distribution.
• Belt or direct drive — standard or
oversized supply fan motors meet a
wide airflow range.
• Eliminates the need for field-installed
components with its built-in anti-short-
cycle timer, time delay relay and
minimum ‘’on’’ time controls.These
controls are factory tested to assure
proper operation.
• Precedent offers ultimate flexibility.
Options and components are not pre-
packaged at the factory. Units are built
to order in our standard “shortest in the
industry” ship cycle time.
RT-PRC005-EN
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Features and
Benefits
Dehumidification (Hot Gas Reheat)
Option
Factory-installed Options
Economizer
This option allows for increased outdoor
air ventilation. It reduces humidity levels
while increasing comfort level in the air
space. Cooling can operate without a
demand for dehumidification.The hot gas
reheat coil is designed to deliver
Equipped with either dry bulb, reference
or comparative enthalpy sensing, this
feature provides free cooling as the
outdoor temperature and/or humidity
decreases. Economizers, correctly
installed, offer a valuable energy
maximum reheat temperatures and
pivot to allow for easy access cleaning.
savings. Factory-installed economizers
save time and ensure proper installation.
Trane Communication Interface
The following options round-out the
complete line of Precedent™ options:
Available factory or field-installed.This
module when applied with ReliaTel™
easily interfaces withTrane’s Integrated
ComfortTM System.
— 0 - 50% Manual or Motorized
Outside Air
Hinged Access Doors
— Hail Protection Quality Coil Guards
— Electric Heaters
These doors permit easy access to the
filter, fan/heat, and compressor/control
sections. They reduce the potential roof
damage from screws or sharp access
door corners.
— Supply and/or Return Smoke
Detectors
— High Pressure Cutout
(standard on 3-phase models with
scroll compressors and all standard
efficiency 3-ton models)
Through the Base Electrical Utility
Access
Factory provided through the base
openings simplify wiring and piping.
Because these utility openings
frequently minimize the number of roof
penetrations, the integrity of roofing
materials is enhanced.
— Thermal ExpansionValve for a wider
range of applications
— Discharge Air Sensor
— Wide array of Zone Sensors and
Thermostats
Unit Mounted Disconnect or Circuit
Breaker
— Factory built Roof Curb
— Power Exhaust
Codes require a method of assured unit
shutdown for servicing. Field-installed
disconnects sometimes interfere with
service access. Factory installation of unit
disconnects reduces costs, assures
proper mounting and provides the
opportunity to upgrade to unit circuit
breaker protection.
— LonTalk Communications Interface
One of Our FinestAssets:
Trane Sales Representatives are a
Support group that can assist you with:
— Product
— Application
Clogged Filter/Fan Fail Switches
— Service
These sensors allow a zone sensor
service light or Integrated Comfort
System to indicate a dirty filter or a fan
that’s not working.The field installation
charges for these valuable feedback
devices often eliminate them from
consideration. Factory installation can
make such features a good investment.
— Training
— Special Applications
— Specifications
— Computer Programs and much more
Precedent has the features and benefits
that make it first class in the light
commercial rooftop market. Designed
with input from field contractors and
engineers, its airflow performance is
outstanding.
Unit Disconnect
Convenience Outlet
Precedent…The sameTrane
quality…with added flexibility.
RT-PRC005-EN
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Features and
Benefits
QualityAnd ReliabilityTesting
• We perform a 100% coil leak test at the
factory.The evaporator and condenser
coils are leak tested at 200 psig and
pressure tested to 450 psig.
• All Precedent™ designs were
rigorously rain tested at the factory to
ensure water integrity.
• All parts are inspected at the point of
final assembly. Sub-standard parts are
identified and rejected immediately.
• Actual shipping tests were performed
to determine packaging requirements.
Units were test shipped around the
country to determine the best
packaging.
• Every unit receives a 100% unit run test
before leaving the production line to
make sure it lives up to rigorousTrane
requirements.
• Factory shake and drop tests were
used as part of the package design
process to help assure that the unit
arrives at the job site in top condition.
We test designs at our factory not on our
customers!
• Rigging tests include lifting a unit into
the air and letting it drop one foot,
assuring that the lifting lugs and rails
hold up under stress.
VariTrac™
ReliaTel
Roof Top Unit
VariTrac
WhenTrane’s changeoverVAV System
for light commercial applications is
coupled with Precedent, it provides the
latest in technological advances for
comfort management systems and can
allow thermostat control in every zone
served byVariTrac.
RT-PRC005-EN
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Application
Considerations
Application of this product should be
within the cataloged airflow and cooling
considerations.
Clearance Requirements
The recommended clearances identified
with unit dimensions should be
maintained to assure adequate service
maximum capacity and peak operating
efficiency. Actual clearances which
appear inadequate should be reviewed
with the localTrane sales personnel.
Low Ambient Cooling
The Precedent™ line features, with
ReliaTel™ microprocessor controls, low
ambient cooling down to 0F. With
electromechanical controls, Precedent
features low ambient cooling to 40F.
Contact your localTrane Representative
for more assistance with low ambient
cooling applications.
Unit Pitch
These units have reversible sloped
condensate drain pans. Units must be
installed level, any unit slope must be
toward the side of unit where
Barometric Relief
condensate drain is connected.
This product line offers an optional
barometric relief damper. for use in
conjunction with economizer option.
This accessory consists of gravity
dampers which open with increased
pressure. As the building air pressure
increases, the pressure in the unit return
air section also increases, opening the
dampers and relieving the conditioned
space.
NOTE:THE EFFECTIVENESS OF
BAROMETRIC RELIEF DAMPER
DURING ECONOMIZING OPERATION
IS SYSTEM RELATED.
PRESSURE DROP OFTHE RETURN AIR
SYSTEM SHOULD BE CONSIDEREDTO
CONTROL BUILDING PRESSURIZA-
TION.
CondensateTrap
The evaporator is a draw-thru
configuration. A trap must be field
provided prior to start-up on the cooling
cycle.
RT-PRC005-EN
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Selection
Procedure
Cooling Capacity
Step 4
In order to select the correct unit which
meets the building’s requirements, the
fan motor heat must be deducted from
the gross cooling capacity.The amount
of heat that the fan motor generates is
dependent on the effort by the motor -
cfm and static pressure.To determine the
total unit static pressure:
Step 1
Heating Capacity
Calculate the building’s total and sensible
cooling loads at design conditions. Use
theTrane calculation methods or any
other standard accepted method.
Step 1
Calculate the building heating load
using theTrane calculation form or other
standard accepted method.
Factors used in unit selection:
Step 2
A
Size the system heating capacity to
Total Cooling Load: 59 MBh
External Static (duct system)
0.45 wg
match the calculated building heating
B
load.The following are building heating
Sensible Cooling Load: 40 MBh
requirements:
Standard Filter 1 in.
fromTable PD-59
0.15 wg
C
A
Airflow: 2000 cfm
Total heating load of 15 MBH
D
Economizer
0.02 wg
B
Electrical Characteristics: 460/60/3
2000 cfm
(100% Return Air) fromTable PD-26
E
C
Summer Design Conditions: Entering
Evaporator Coil: 80 DB, 67WB Outdoor
Ambient: 95
460 volt/3 phase Power Supply
Electric Heater Size 6 kW 0.05 wg
fromTable PD-51
The electric heat accessory capacities
are listed inTable PD-62 From the table, a
6 kW heater will deliver 20.48 MBH at
480 volts. In order to determine capacity
at 460 volts, the heater voltage
correction factor fromTable PD-60 must
be used.Therefore, 20.48 MBH x .9118
(voltage correction factor) = 18.80 MBH.
F
External Static Pressure: 0.45 in. wg
Total Static Pressure
0.67 wg
Step 2
As a starting point, a rough
Note:The Evaporator Fan Performance
Table PD-20 has deducted the pressure
drop for a 1 in. filter already in the unit
(see note belowTable PD-20).Therefore,
the actual total static pressure is 0.67 -
0.15 (fromTable PD - 26) = 0.52 wg.
determination must be made of the size
of the unit.The final selection will be
made after examining the performance
at the given conditions. Divide the total
cooling load by nominal BTUH per ton
(12 MBh per ton); then round up to the
nearest unit size.
Air Delivery Selection
External static pressure drop through
the air distribution system has been
calculated to be 0.45 inches of water.
FromTable PD-59 static pressure drop
through the economizer is 0.02 and the
6 kW heater is 0.05 inches of water (0.45
+ 0.02 + 0.05). EnterTable PD-20 for a
TSC060A4 at 2000 cfm and 0.52 static
pressure.The standard direct drive
motor at high speed will give the
With 2000 cfm and 0.52 wg.
Table PD-20 shows .90 bhp for this unit.
Note below the table gives a formula to
calculate Fan Motor Heat,
4.39 x bhp = MBH.
4.39 x .90 = 3.95 MBH.
60 MBh / 12 MBh = 5Tons
Step 3
Table PD-4 shows that aTSC060A4 has a
gross cooling capacity of 63.1 MBh and
48.2 MBh sensible capacity at 2000 cfm
and 95 DB outdoor ambient with 80 DB,
67WB air entering the evaporator.
Now subtract the fan motor heat from
the gross cooling capacity of the unit:
NetTotal Cooling Capacity
desired airflow at a rated bhp of 0.90.
= 60 MBH - 3.95 = 56.05 MBH.
To Find Capacity at Intermediate
Conditions Not in theTable
Net Sensible Cooling Capacity
= 48.2 MBH - 3.95 = 44.25 MBH.
When the design conditions are between
two numbers that are in the capacity
table, interpolation is required to
approximate the capacity. Note:
Extrapolation outside of the table
conditions is not recommended.
Step 5
If the performance will not meet the
required load of the building’s total or
sensible cooling load, try a selection at
the next higher size unit.
RT-PRC005-EN
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Model
Number
Description
T
1
S
2
C 036 A
3 4,5,6 7
3
8
R
9
B
A
**
C
0
0
0
A
1
0
0
0
1
A
1
10 11 12,13 14 15 16 17 18 19 20 21 22 23 24 25
DIGIT 1 - Unit Function
DIGIT 11 - Minor Design Sequence
DIGIT 20 - Convenience Outlet
T = DX Cooling
A = First Sequence
0 = No Convenience Outlet
A = Unpowered Convenience Outlet
B = Powered Convenience Outlet
(3 phase only)
DIGIT 2 - Efficiency
DIGITS 12, 13 - Service Sequence
S = Standard Efficiency
H = High Efficiency
**= Factory Assigned
DIGIT 21 - Communications Options
DIGIT 14 - Fresh Air Selection
DIGIT 3 -Airflow
0 = No Communications Interface
1 = Trane Communications Interface
2 = LonTalk® Communications Interface
3 = Novar 2024 Controls
0 = No Fresh Air
C = Convertible
A = Manual Outside Air Damper 0-50%
B = Motorized Outside Air Damper 0-50%
C = Economizer, Dry Bulb 0-100%
without Barometric Relief
DIGITS 4,5,6 - Nominal Gross Cooling
Capacity (MBh)
4 = Novar 3051 Controls
D = Economizer, Dry Bulb 0-100%
with Barometric Relief
E = Economizer, Reference Enthalpy
0-100% without Barometric Relief
F = Economizer, Reference Enthalpy
0-100% with Barometric Relief
G = Economizer, Comparative Enthalpy
0-100% without Barometric Relief
H = Economizer, Comparative Enthalpy
0-100% with Barometric Relief
036 =
048 =
060 =
072 =
090 =
092 =
102 =
120 =
3Ton
DIGIT 22 - Refrigeration System Option
4Ton
0 = Standard Refrigeration System
A = Thermal Expansion Valve (TXV)
B = Dehumidification (Hot Gas Reheat Coil)
5Ton
6Ton
7½Ton, Single Compressor
7½Ton, Dual Compressor
8½Ton
DIGIT 23 - Refrigeration Controls
10Ton
0 = No Refrigeration Control
1 = High Pressure Control
2 = Frostat
DIGIT 7 - Major Design Sequence
3 = Crankcase Heater
A = First
DIGIT 15 - Supply Fan/DriveType/Motor
4 = High Pressure Control and Frostat
5 = High Pressure Control and Crankcase
Heater
0 = Standard Drive
1 = Oversized Motor
2 = Optional Belt Drive Motor
DIGIT 8 - UnitVoltage
6 = Frostat and Crankcase Heater
7 = High Pressure Control, Frostat and
Crankcase Heater
1 = 208-230/60/1
3 = 208-230/60/3
4 = 460/60/3
W= 575/60/3
K = 380/60/3
DIGIT 16 - Hinged ServiceAccess/Filters
0 = Standard Panels/Standard Filters
A = Hinged Access Panels/Standard Filters
B = Standard Panels/2” Pleated Filters
C = Hinged Access Panels/2” Pleated Filters
DIGIT 24 - Smoke Detector
0 = No Smoke Detector
A = Return Air Smoke Detector
B = Supply Air Smoke Detector
C = Supply and Return Air Smoke
Detectors
DIGIT 9 - Unit Controls
E = Electromechanical
R = ReliaTel™Microprocessor
DIGIT 17 - Condenser Coil Protection
DIGIT 10 - Heating Capacity
0 = Standard Coil
DIGIT 25 - Monitoring Controls
1 = Standard Coil with Hail Guard
2 = Epoxy Coated Condenser Coil
3 = Epoxy Coated Condenser Coil with
Hail Guard
0 = No Electric Heat
A = 5 kW (1 phase)
B = 6 kW (3 phase)
C = 9 kW (3 phase)
D = 10 kW (1 phase)
E = 12 kW (3 phase)
F = 14 kW (1 phase)
G = 18 kW (1 and 3 phase)
J = 23 kW (3 phase)
K = 27 kW (3 phase)
N = 36 kW (3 phase)
P = 54 kW (3 phase)
0 = No Monitoring Control
1 = Clogged Filter Switch
2 = Fan Failure Switch
3 = Discharge Air SensingTube
4 = Clogged Filter Switch and Fan Fail
Switch
5 = Clogged Filter Switch and Discharge
Air SensingTube
6 = Fan Fail Switch and Discharge Air
SensingTube
DIGIT 18 -Through the Base Provisions
0 = NoThrough the Base Provisions
A = Through the Base Electric
DIGIT 19 - Disconnect/Circuit Breaker
(3 phase only)
7 = Clogged Filter and Fan Fail Switches
and Discharge Air SensingTube
8 = Novar Return Air Sensor
0 = No Disconnect or Circuit Breaker
1 = Non-Fused Disconnect
2 = Circuit Breaker
Example:
Model number TSC036A3RBA**C000A10001A1 describes a unit with the following characteristics: DX Cooling, 3 ton nominal cooling capacity, 208-230/60/3 power
supply, ReliaTel™ controls, 6 kW electric heater model. 0-100% dry bulb economizer without barometric relief, standard direct drive motor, standard access panels/
filters, standard condenser coil with no coil protection, through the base electric, non-fused disconnect, no convenience outlet or communications interface, standard
refrigeration coil, high pressure control, return air smoke detector, and clogged filter switch.
RT-PRC005-EN
10
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
(3 - 5Ton)
Standard Efficiency
Table GD - 1 — General Data
3Ton Convertible Units
TSC036A1, A3, A4, AW
4Ton Convertible Units
TSC048A1 TSC048A3, A4, AW
5Ton Convertible Units
TSC060A1 TSC060A3, A4, AW TSC060AK
Cooling Performance1
Gross Cooling Capacity
SEER2
37,400
10.75
50,300
10.1
49,200
10.0
63,100
9.9
63,100
10.2
63,100
10.2
Nominal CFM / ARI Rated CFM
ARI Net Cooling Capacity
System Power (kW)
1,200/1,200
36,000
3.918
1,600/1,600
48,000
5.28
1,600/1,600
47,000
2,000/2,000
60,000
6.86
2,000/2,000
60,000
6.78
2,000/2,000
60,000
6.78
5.40
Compressor
No./Type
Outdoor Sound Rating (dB)3
1/Recip.
83
1/Scroll
86
1/Scroll
82
1/Scroll
84
1/Scroll
84
1/Scroll
84
Outdoor Coil —Type
Tube Size (in.) O.D.
Face Area (sq ft)
Rows/FPI
Lanced
0.3125
7.19
Lanced
0.3125
6.17
Lanced
0.3125
9.59
Lanced
0.3125
8.81
Lanced
0.3125
8.81
Lanced
0.3125
8.81
2/17
2/17
1/17
2/17
2/17
2/17
Indoor Coil —Type
Tube Size (in.)
Lanced
0.3125
Lanced
0.3125
Lanced
0.3125
Lanced
0.3125
Lanced
0.3125
Lanced
0.3125
Face Area (sq ft)
5.67
6.68
6.17
5.00
5.00
5.00
Rows/FPI
2/16
3/16
3/16
3/16
3/16
3/16
Refrigerant Control
Drain Connection No./Size (in.)
Short Orifice
1/¾ NPT
Short Orifice
1/¾ NPT
Short Orifice
1/¾ NPT
Short Orifice
1/¾ NPT
Short Orifice
1/¾ NPT
Short Orifice
1/¾ NPT
Outdoor Fan —Type
No. Used/Diameter (in.)
DriveType/No. Speeds
CFM
Propeller
1/22
Direct/1
Propeller
1/22
Direct/1
Propeller
1/22
Direct/1
Propeller
1/22
Direct/1
Propeller
1/22
Direct/1
Propeller
1/22
Direct/1
2550
2850
3610
3470
3470
3470
No. Motors/HP
1/.20
1/.33
1/.33
1/.33
1/.33
1/.40
Motor RPM
1115
1115
1115
1115
1115
1115
Direct Drive Indoor Fan —Type
No. Used
FC Centrifugal
1
FC Centrifugal
1
FC Centrifugal
1
FC Centrifugal
1
FC Centrifugal
1
FC Centrifugal
1
Diameter xWidth (in.)
DriveType/No. Speeds
No. Motors
10 x 10
Direct/2
1
11 x 11
Direct/2
1
11 x 11
Direct/2
1
11 x 11
Direct/2
1
11 x 11
Direct/2
1
12x11/–
Direct/2
1
Motor HP (Standard/Oversized)
Motor RPM (Low/High Speed)
Oversized Motor RPM
(Low/High Speed)
.33/.50
950/1060
.60/.80
930/1000
.60/.80
930/1000
.90/1.00
985/1100
.90/1.00
985/1100
1.0/–
935/1100
1100/1145
1000/1100
1000/1100
1080/1135
1080/1135
—
Motor Frame Size
(Standard/Oversized)
48/48
48/48
48/48
48/48
48/48
48/—
Belt Drive Indoor Fan —Type
No. Used
FC Centrifugal
—
—
—
—
—
—
—
—
FC Centrifugal
—
—
—
—
—
—
—
—
FC Centrifugal
—
—
—
—
—
—
—
—
1
1
1
Diameter xWidth (in.)
DriveType/No. Speeds
No. Motors
Motor HP
Motor RPM
11 x 11
11 x 11
Belt/Variable Speed
11 x 11
Belt/Variable Speed
Belt/Variable Speed6
1
1
1
1.00
1750
56
1.00
1750
56
1.00
1750
56
Motor Frame Size
Filters —Type Furnished 7
Throwaway
(2) 20 x 25 x 1
Throwaway
(2) 20 x 25 x 1
Throwaway
(2) 20 x 25 x 1
Throwaway
(2) 20 x 25 x 1
Throwaway
(2) 20 x 25 x 1
Throwaway
(2) 20 x 25 x 1
(No.) Size Recommended (in.)
Refrigerant Charge (Lbs of R-22)4
3.8
4.4
3.8
4.7
4.9
4.9
NOTES:
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net
and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Certified in accordance with the Unitary Air-Conditioner Equipment
certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz).
2. SEER is rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For more information refer to Table PD-51
4. Refrigerantchargeisanapproximatevalue. Foramoreprecisevalue, seeunitnameplateandserviceinstructions.
5. TSC036A1SEERis10.5.
6. BeltDriveMotorisnotavailableforTSC036A1.
7. Optional2”PleatedFiltersalsoavailable.
8. TSC036A1SystemPower(kW)is3.79.
RT-PRC005-EN
11
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
(6 - 10Ton)
Standard Efficiency
Table GD - 2— General Data
6 Ton
Convertible Units
7½ Ton
Convertible Units
8½ Ton
Convertible Units
10 Ton
Convertible Units
TSC072A3, A4, AW, AK TSC090A3,A4,AW, AK TSC092A3, A4, AW
TSC102A3, A4, AW, AK TSC120A3, A4, AW, AK
Cooling Performance1
Gross Cooling Capacity
EER
72,000
10.3
95,000
10.3
92,000
10.3
105,000
10.3
118,000
10.46
2
Nominal CFM / ARI Rated CFM
ARI Net Cooling Capacity
Integrated Part LoadValue (IPLV)3
System Power (kW)
Compressor
2,400/2,100
3,000/2,625
3,000/2,625
87,000
11.18
3,400/3,000
100,0007
11.98
4,000/3,200
112,0 0 07
11.58
69,000
90,000
—
—
6.7
8.74
8.45
9.719
10.779
No./Type
1/Scroll
88
Lanced
0.3125
13.88
2/17
1/Scroll
90
Lanced
0.3125
17.00
2/Scrolls
87
Lanced
0.3125
17.00
2/Scrolls
86
Lanced
0.3125
19.83
2/Scrolls
86
Lanced
0.3125
25.92
2/17
Outdoor Sound Rating (dB)4
Outdoor Coil —Type
Tube Size (in.) O.D.
Face Area (sq ft)
Rows/FPI
3/17
2/17
2/17
Indoor Coil —Type
Tube Size (in.)
Lanced
0.3125
Lanced
0.3125
Lanced
0.3125
Lanced
0.3125
Lanced
0.3125
Face Area (sq ft)
9.89
9.89
9.89
12.36
12.36
Rows/FPI
2/16
3/16
3/16
3/16
4/16
Refrigerant Control
Drain Connection No./Size (in.)
Short Orifice
1/¾ NPT
Short Orifice
1/¾ NPT
Short Orifice
1/¾ NPT
Short Orifice
1/¾ NPT
Short Orifice
1/¾ NPT
Outdoor Fan —Type
No. Used/Diameter (in.)
DriveType/No. Speeds
CFM
Propeller
1/26
Propeller
1/26
Propeller
1/26
Direct/1
6500
1/0.70
1115
Propeller
1/26
Direct/1
7100
1/0.75
1115
Propeller
1/26
Direct/1
7000
1/0.75
1115
Direct/1
6100
Direct/1
6200
No. Motors/HP
Motor RPM
1/0.7011
1115
1/0.7011
1115
Belt Drive Indoor Fan —Type
FC Centrifugal
FC Centrifugal
FC Centrifugal
FC Centrifugal
FC Centrifugal
No. Used
1
1
1
1
1
Diameter xWidth (in.)
DriveType/No. Speeds
No. Motors
Motor HP (Standard/Oversized)
Motor RPM (Standard/Oversized)
Motor Frame Size
12 x 12
Belt/Variable Speed
12 x 12
Belt/Variable Speed
12 x 12
Belt/Variable Speed
15 x 15
Belt/Variable Speed
15 x 15
Belt/Variable Speed
1
1.00/2.0012
1750
1
2.00/3.00
1750
1
2.00/3.00
1750
1
2.00/3.00
1750
1
3.00/5.00
1750/3450
56
Throwaway
(4) 20 x 25 x 2
8.4Circuit 1
6.6 Circuit 2
56
56
56
56
Filters —Type Furnished 10
(No.) Size Recommended (in.)
Refrigerant Charge (Lbs of R-22)5
Throwaway
(4) 16 x 25 x 2
7.1
Throwaway
(4) 16 x 25 x 2
11.9
Throwaway
(4) 16 x 25 x 2
6.2 Circuit 1
3.4 Circuit 2
Throwaway
(4) 20 x 25 x 2
7.9 Circuit 1
4.0 Circuit 2
NOTES:
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is net
and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Certified in accordance with the Unitary Air-Conditioner Equipment
certification program, which is based on ARI Standard 210/240 except AK (380V/60 Hz).
2. SEER is rated at ARI conditions and in accordance with DOE test procedures.
3. Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb ar ARI
rated cfm.
4. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For more information refer to Table PD-51.
5. Refrigerantchargeisanapproximatevalue. Foramoreprecisevalue, seeunitnameplateandserviceinstructions.
6. EER shown is for downflow airflow. EER for horizontal airflow is 10.3.
7. ARI Net Cooling Capacity shown is for downflow airflow. Cooling Capacity for Horizontal airflow TSC102A is 99,000; TSC120A is 111,000.
8. Integrated Part Load Value (IPLV) shown is for downflow airflow. IPLV for Horizontal airflow TSC092A is 10.8, TSC102A is 11.5; TSC120A is 11.0.
9. System Power (kW) shown is for downflow airflow. System Power (kW) forHorizontal airflow TSC102A is 9.61; for TSC120A is 10.78.
10. Optional2”PleatedFiltersalsoavailable.
11. Outdoor motor is 0.75 hp for AK (380V/60 Hz units).
12. Standard indoor motor is 2.00 hp for AK (380V/60 Hz) units.
RT-PRC005-EN
12
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
(3 - 5Ton)
High Efficiency
Table GD - 3 — General Data
3Ton
4Ton
5 Ton
Convertible Units
Convertible Units
Convertible Units
THC036A1,A3,A4,AW
THC048A1,A3,A4,AW
THC060A1
THC060A3,A4,AW
Cooling Performance1
Gross Cooling Capacity
38,000
49,800
62,100
62,400
SEER / EER2
12.5/—
12.0/—
11.8/—
12.0/ —
Nominal CFM / ARI Rated CFM
1,200/1,200
1,600/1,600
2,000/2,000
2,000/2,000
ARI Net Cooling Capacity
System Power (kW)
Compressor
36,600
3.33
47,500
4.48
59,000
5.73
59,500
5.56
No./Type
1/Climatuff Scroll
83
1/Climatuff Scroll
85
1/Climatuff Scroll
84
1/Climatuff Scroll
84
Outdoor Sound Rating (dB)3
Outdoor Coil —Type
Tube Size (in.) O.D.
Face Area (sq ft)
Lanced
0.3125
7.19
Lanced
0.3125
9.59
Lanced
0.3125
10.96
Lanced
0.3125
10.96
Rows/FPI
2/17
3/17
3/17
3/17
Indoor Coil —Type
Tube Size (in.)
Lanced
0.3125
6.68
Lanced
0.3125
6.68
Lanced
0.3125
7.71
Lanced
0.3125
7.71
Face Area (sq ft)
Rows/FPI
3/16
4/16
4/16
4/16
Refrigerant Control
Drain Connection No./Size (in.)
Outdoor Fan —Type
No. Used/Diameter (in.)
DriveType/No. Speeds
CFM
Short Orifice
1/¾ NPT
Propeller
1/22
Direct/1
2550
Short Orifice
1/¾ NPT
Propeller
1/22
Direct/1
3050
Short Orifice
1/¾ NPT
Propeller
1/22
Direct/1
3170
Short Orifice9
1/¾ NPT
Propeller
1/22
Direct/110
3370
No. Motors/HP
1/.20
1/.33
1/.33
1/.33
Motor RPM
1115
1115
1115
1115
Direct Drive Indoor Fan —Type
No. Used
FC Centrifugal
1
FC Centrifugal
1
FC Centrifugal
1
FC Centrifugal
1
Diameter xWidth (in.)
DriveType/No. Speeds
No. Motors
10 x 10
Direct/2
1
11 x 11
Direct/2
1
11 x 11
Direct/2
1
11 x 11
Direct/2
1
Motor HP (Standard/Oversized)
Standard Motor RPM (Low/High Speed)
Oversized Motor RPM (Low/High Speed)
Motor Frame Size (Standard/Oversized)
Belt Drive Indoor Fan —Type
No. Used
.33/.50
950/1060
1100/1145
48/48
FC Centrifugal
1
.60/.80
930/1000
1000/1100
48/48
FC Centrifugal
1
.90/1.00
985/1100
1080/1135
48/48
.90/1.00
985/1100
1080/1135
48/48
FC Centrifugal
1
—
—
Diameter xWidth (in.)
11 x 11
11 x 11
—
11 x 11
DriveType/No. Speeds
Belt/Variable Speed 6
1
Belt/Variable Speed 6
1
—
Belt/Variable Speed
No. Motors
—
1
Motor HP
Standard Motor RPM
Motor Frame Size
1.00
1750
56
1.00
1750
56
—
—
—
1.00
1750
56
Filters —Type Furnished 7
(No.) Size Recommended (in.)
Optional Hot Gas Reheat Coil -Type
Tube Size (in.) OD
Face Area (sq. ft)
Rows/FPI
Refrigerant Charge (Lbs of R-22)4
Standard
Throwaway
(2) 20 x 25 x 1
Throwaway
(2) 20 x 25 x 1
Throwaway
(2) 20 x 30 x 1
Throwaway
(2) 20 x 30 x 111
Lanced
0.375
—
—
—
—
—
—
—
—
—
—
—
—
2.22
2/18
5.38
—
7. 7 5
—
7.9
—
8.4
10.7
Optional Hot Gas Reheat Coil
NOTES:
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is
net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Units are certified in accordance with the Unitary Air-Conditioner
Equipment certification program, which is based on ARI Standard 210/240.
2. EER and SEER are rated at ARI conditions and in accordance with DOE test procedures.
3. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For more information refer to Table PD-51
4. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
5. Refrigerant Charge shown is for 3 phase. 1 phase Refrigerant Charge is 8.1.
6. Belt Drive Motor is not available for THC036A1, THC048A1.
7. Optional 2” Pleated Filters also available.
8. Refrigerant Charge shown is for 3 phase. 1 phase Refrigerant Charge is 4.5.
9. TXV is supplied from the factory as standard with the Dehumidification (Hot Gas Reheat) option.
10. With Dehumidification (Hot Gas Reheat) option: Direct/2.
11. 2" pleated filters is a factory installed option. 2" pleated filters is standard with the Dehumidification (Hot Gas Reheat) option.
RT-PRC005-EN
13
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
(6 - 10Ton)
High Efficiency
Table GD - 4— General Data
6 Ton
7½ Ton
8½ Ton
10 Ton
Convertible Units
THC072A3, A4, AW
Convertible Units
THC092A3, A4, AW
Convertible Units
THC102A3, A4. AW
Convertible Units
THC120A3, A4, AW
Cooling Performance1
Gross Cooling Capacity
73,000
11.56
94,000
11.56
103,000
11.56
117,000
11.26
2
EER
Nominal CFM / ARI Rated CFM
ARI Net Cooling Capacity
Integrated Part LoadValue (IPLV)3
System Power (kW)
Compressor
2,400/2,100
3,000/2,625
90,00010
11.98
3,400/3,000
98,00010
12.18
4,000/3,200
109,00010
12.08
70,000
—
6.097
7. 8 3 7
8.527
9.737
No./Type
1/Climatuff Scroll
2/Climatuff Scrolls
2/Climatuff Scrolls
2/Climatuff Scrolls
88
Outdoor Sound Rating (dB)4
Outdoor Coil —Type
Tube Size (in.) O.D.
Face Area (sq ft)
89
Lanced
0.3125
17.00
91
Lanced
0.3125
17.50
89
Lanced
0.3125
19.83
Lanced
0.3125
27.21
Rows/FPI
3/17
3/17
3/17
3/17
Indoor Coil —Type
Tube Size (in.)
Lanced
0.3125
9.89
Lanced
0.3125
12.36
Lanced
0.3125
12.36
Lanced
0.3125
12.36
Face Area (sq ft)
Rows/FPI
3/16
3/16
4/16
5/16
Refrigerant Control
Drain Connection No./Size (in.)
Outdoor Fan —Type
No. Used/Diameter (in.)
DriveType/No. Speeds
CFM
Short Orifice
1/¾ NPT
Propeller
1/26
Direct/1
6100
Short Orifice
1/¾ NPT
Propeller
1/26
Direct/1
6200
Short Orifice
1/¾ NPT
Propeller
1/26
Direct/1
6600
Short Orifice
1/¾ NPT
Propeller
1/26
Direct/1
7000
No. Motors/HP
Motor RPM
1/0.70
1075
1/0.70
1075
1/0.75
1075
1/0.75
1075
Belt Drive Indoor Fan —Type
No. Used
FC Centrifugal
1
FC Centrifugal
1
FC Centrifugal
1
FC Centrifugal
1
Diameter xWidth (in.)
DriveType/No. Speeds
No. Motors
12 x 12
Belt/Variable Speed
1
15 x 15
Belt/Variable Speed
1
15 x 15
Belt/Variable Speed
1
15 x 15
Belt/Variable Speed
1
Motor HP (Standard/Oversized)
Motor RPM (Standard/Oversized)
Motor Frame Size
1.00/2.00
1750
56
2.00/3.00
1750
56
2.00/3.00
1750
3.00/5.00
1750/3450
56
56
Filters —Type Furnished 9
(No.) Size Recommended (in.)
Optional Hot Gas Reheat Coil —Type
Tube Size (in.) OD
Throwaway
(4) 16 x 25 x 2
—
Throwaway
(4) 20 x 25 x 2
—
Throwaway
(4) 20 x 25 x 2
—
Throwaway
(4) 20 x 25 x 2
Lanced
0.375
—
—
—
Face Area (sq. ft.)
—
—
—
5.19
Rows/FPI
—
10.7
—
—
2/16
11.0 Circuit 1
7.3Circuit 2
Refrigerant Charge (Lbs of R-22)5
6.4 Circuit 1
6.2 Circuit 2
7.4 Circuit 1
7.1Circuit 2
NOTES:
1. Cooling Performance is rated at 95 F ambient, 80 F entering dry bulb, 67 F entering wet bulb. Gross capacity does not include the effect of fan motor heat. ARI capacity is
net and includes the effect of fan motor heat. Units are suitable for operation to 20% of nominal cfm. Certified in accordance with the Unitary Air-Conditioner Equipment
certification program, which is based on ARI Standard 210/240.
2. SEER is rated at ARI conditions and in accordance with DOE test procedures.
3. Integrated Part Load Value is rated in accordance with ARI Standard 210/240 or 360. Units are rated at 80°F ambient, 80°F entering dry bulb, and 67°F entering wet bulb ar
ARI rated cfm.
4. Outdoor Sound Rating shown is tested in accordance with ARI Standard 270. For more information refer to Table PD-51.
5. Refrigerant charge is an approximate value. For a more precise value, see unit nameplate and service instructions.
6. EER shown is for downflow airflow. EER for horizontal airflow: THC072A - 11.3, THC092A and THC102A - 11.3, THC120A - 10.7.
7. System Power (kW) shown is for downflow airflow. System Power (kW) for horizontal airflow: THC072A - 6.2, THC092A - 7.88, THC102A - 8.58, THC120A - 10.09.
8. Integrated Part Load Value (IPLV) shown is for downflow airflow. IPLV for horizontal airflow: THC092A - 11.5, THC102A - 11.6, THC120A - 11.5.
9. Optional 2” Pleated Filters also available.
10. Net Cooling Capacity shown is for downflow airflow. Net Cooling for horizontal airflow: THC092A - 89,000, THC102A - 97,000, THC120A - 108,000.
RT-PRC005-EN
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance (3, 4Ton)
Data
Standard Efficiency
Table PD-1 — Gross Cooling Capacities (MBH) 3 Ton Single/Three Phase TSC036A1, A3, A4, AW
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 34.6 29.0 38.6 22.3 40.6 14.7 31.2 27.3 36.6 21.1 39.5 13.8 28.2 25.6 33.4 19.6 37.8 12.9 25.1 24.1 29.6 18.2 35.5 11.9
80 35.6 35.0 38.8 27.3 41.0 20.2 32.6 32.6 36.8 26.6 39.8 19.5 30.0 30.0 33.5 25.2 38.0 18.5 27.3 27.3 29.9 23.5 35.6 17.5
1080
1200
1320
85
37.6 37.6 39.2 32.5 41.5 24.7 35.6 35.6 37.2 32.2 40.1 24.2 32.8 32.8 34.2 31.0 38.2 23.8 30.1 30.1 30.7 29.3 35.8 23.0
90 39.3 39.3 39.7 37.6 42.0 29.2 37.8 37.8 37.9 37.6 40.4 29.1 35.7 35.7 35.7 35.7 38.5 28.9 33.0 33.0 32.9 32.9 36.0 28.4
75 35.6 30.9 39.0 22.8 40.9 14.9 32.2 29.2 37.3 22.1 39.8 14.1 29.0 27.5 34.3 20.7 38.2 13.1 25.9 25.9 30.4 19.0 36.0 12.1
80 36.7 36.7 39.3 28.4 41.4 20.6 34.3 34.3 37.4 28.1 40.2 20.3 31.4 31.4 34.5 26.9 38.4 19.3 28.6 28.6 30.7 25.2 36.1 18.3
85 38.7 38.7 39.7 33.9 41.9 25.3 37.0 37.0 37.9 34.0 40.5 25.0 34.5 34.5 35.3 33.2 38.7 24.8 31.5 31.5 31.7 31.6 36.3 24.2
90 40.2 40.2 40.4 39.2 42.3 30.1 38.8 38.8 38.8 38.8 40.9 30.2 37.1 37.1 37.0 37.0 39.1 30.3 34.6 34.6 34.6 34.6 36.6 30.0
75 36.4 32.6 39.4 23.5 41.1 15.1 33.2 31.0 37.7 23.0 40.1 14.3 29.8 29.3 34.9 21.8 38.5 13.4 26.8 26.8 30.9 20.0 36.3 12.4
80
37.7 37.7 39.7 29.4 41.6 20.9 35.7 35.7 37.9 29.3 40.4 21.2 32.7 32.7 35.2 28.5 38.7 19.9 29.8 29.8 31.4 26.8 36.5 19.0
85 39.4 39.4 40.2 35.2 42.1 25.9 37.9 37.9 38.5 35.6 40.8 25.7 35.9 35.9 36.2 35.3 39.1 25.7 32.9 32.9 32.9 32.9 36.7 25.3
90 40.8 40.8 40.9 40.5 42.6 30.8 39.7 39.7 39.6 39.6 41.2 31.2 38.0 38.0 38.0 38.0 39.5 31.6 35.9 35.9 35.9 35.9 37.1 31.5
75
37.0 34.1 39.7 24.0 41.3 15.3 34.1 32.8 38.0 23.7 40.3 14.5 30.6 30.6 35.5 22.7 38.7 13.6 27.7 27.7 31.4 21.0 36.6 12.6
80 38.4 38.4 40.0 30.3 41.8 21.2 36.7 36.7 38.3 30.5 40.8 21.0 33.9 33.9 35.8 30.0 39.0 20.4 30.8 30.8 32.0 28.4 36.8 19.7
85 40.0 40.0 40.6 36.3 42.4 26.4 38.7 38.7 39.0 37.0 41.2 26.7 36.8 36.8 36.8 36.8 39.4 26.6 34.2 34.2 34.2 34.2 37.0 26.4
1440
90
41.4 41.4 41.4 41.4 42.9 31.6 40.3 40.3 40.3 40.3 41.5 32.1 38.7 38.7 38.7 38.7 39.9 32.7 36.7 36.7 36.7 36.7 37.6 33.0
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
Table PD-2 — Gross Cooling Capacities (MBH) 4 Ton Single Phase TSC048A1
AmbientTemperature (F)
85
95
105
67
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 45.5 38.7 52.4 30.0 56.4 20.1 41.6 36.6 49.0 28.3 54.4 18.9 37.6 34.5 44.4 26.7 51.8 17.5 33.5 32.3 39.8 24.5 48.0 15.8
80 46.5 46.5 52.5 37.6 56.8 28.1 43.2 43.2 49.1 35.9 54.8 26.7 39.9 39.9 44.6 33.8 52.0 25.2 36.5 36.5 40.1 31.6 48.2 23.4
85 50.3 50.3 53.0 45.1 57.4 34.9 47.0 47.0 49.7 43.7 55.0 33.9 43.6 43.6 45.3 41.6 52.2 32.8 40.2 40.2 41.0 39.5 48.3 31.0
90 53.3 53.3 53.8 52.5 57.7 41.1 50.8 50.8 50.8 50.8 55.5 41.0 47.5 47.5 47.5 47.5 52.5 40.1 44.0 44.0 44.0 44.0 48.6 38.6
75 46.8 41.3 53.1 31.3 56.9 20.5 42.7 39.1 50.1 29.7 55.0 19.2 38.7 37.0 45.4 27.5 52.4 17.9 34.4 34.4 40.8 25.4 48.9 16.3
80 48.7 48.7 53.4 39.5 57.5 28.9 45.2 45.2 50.3 38.2 55.4 27.8 41.8 41.8 45.7 36.0 52.7 26.3 38.2 38.2 41.1 33.9 49.1 24.7
85 52.2 52.2 53.9 47.5 58.1 36.1 49.3 49.3 51.0 46.7 55.7 35.3 45.7 45.7 46.7 44.7 52.9 34.5 42.1 42.1 42.1 42.1 49.2 33.0
90 54.9 54.9 54.9 54.9 58.4 42.8 52.7 52.7 52.7 52.7 56.2 42.9 49.8 49.8 49.8 49.8 53.3 42.5 46.2 46.2 46.2 46.2 49.7 41.3
75 48.1 43.8 53.6 32.5 57.3 20.8 43.8 41.6 50.8 31.1 55.5 19.6 39.8 39.5 46.3 29.0 52.9 18.2 35.8 35.8 41.5 26.7 49.6 16.7
80 50.5 50.5 54.0 41.2 58.0 29.6 47.1 47.1 51.1 40.3 55.9 29.0 43.4 43.4 46.7 38.2 53.2 27.4 39.8 39.8 42.0 36.0 49.7 25.8
85 53.6 53.6 54.8 49.8 58.6 37.1 51.1 51.1 52.0 49.4 56.3 36.6 47.7 47.7 48.1 47.9 53.5 36.1 43.9 43.9 43.9 43.9 49.9 34.9
90 56.1 56.1 56.1 56.1 59.0 44.2 54.2 54.2 54.1 54.1 56.9 44.8 51.5 51.5 51.5 51.5 54.1 44.7 48.2 48.2 48.2 48.2 50.5 43.9
1440
1600
1760
75 49.1 46.3 54.2 33.5 57.7 21.2 44.9 44.0 51.5 32.4 55.9 20.0 40.7 40.7 47.1 30.4 53.3 18.6 37.0 37.0 42.2 28.1 50.1 17.0
80
85 54.7 54.7 55.5 51.8 59.1 38.1 52.5 52.5 52.9 51.8 56.8 37.8 49.4 49.4 49.4 49.4 54.1 37.6 45.5 45.5 45.5 45.5 50.5 36.6
90 57.1 57.1 57.1 57.1 59.4 45.6 55.3 55.3 55.3 55.3 57.4 46.4 52.8 52.8 52.8 52.8 54.7 46.7 49.8 49.8 49.8 49.8 51.3 46.2
51.9 51.9 54.6 42.7 58.4 30.1 48.8 48.8 51.8 42.2 56.3 30.2 45.0 45.0 47.7 40.4 53.7 28.5 41.2 41.2 42.9 38.2 50.3 26.9
1920
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
RT-PRC005-EN
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance (4, 5Ton)
Data
Standard Efficiency
Table PD-3 — Gross Cooling Capacities (MBH) 4 Ton Three Phase TSC048A3, A4, AW
AmbientTemperature (F)
85
95
105
67
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 44.8 38.6 51.4 29.8 56.1 20.1 41.0 36.6 48.2 28.2 53.7 18.9 37.3 34.7 44.2 26.4 50.8 17.6 33.4 32.7 39.6 25.2 47.1 16.0
80 46.0 46.0 51.6 37.4 56.5 27.9 42.9 42.9 48.3 35.8 54.0 26.6 39.7 39.7 44.4 34.0 51.0 25.2 36.4 36.4 40.0 32.0 47.2 23.6
85 49.6 49.6 52.0 44.8 56.7 34.8 46.8 46.8 48.9 43.6 54.2 34.0 43.6 43.6 45.1 41.8 51.2 32.7 40.3 40.3 41.0 39.8 47.4 31.1
90 52.5 52.5 52.9 52.2 57.2 41.6 50.2 50.2 50.1 50.1 54.6 41.1 47.2 47.2 47.2 47.2 51.5 40.1 43.9 43.9 43.9 43.9 47.7 38.6
75 46.1 41.1 52.1 31.1 56.7 20.5 42.1 39.0 49.1 29.6 54.4 19.3 38.3 37.1 45.1 27.8 51.5 18.0 34.3 34.3 40.6 25.7 47.9 16.5
80 48.1 48.1 52.4 39.3 57.2 29.0 44.9 44.9 49.2 37.9 54.7 27.7 41.5 41.5 45.4 36.2 51.7 26.3 38.1 38.1 41.0 34.2 48.0 24.8
1440
1600
1760
85
90 54.2 54.2 54.2 54.2 58.0 43.5 51.9 51.9 51.9 51.9 55.4 43.2 49.1 49.1 49.1 49.1 52.3 42.5 45.9 45.9 45.9 45.9 48.7 41.3
75 47.2 43.5 52.8 32.3 57.3 20.9 43.3 41.5 49.8 30.9 54.9 19.7 39.1 39.1 45.8 29.1 52.0 18.3 35.6 35.6 41.3 27.1 48.5 16.8
51.4 51.4 53.0 47.3 57.7 36.7 48.7 48.7 50.0 46.4 55.0 35.5 45.6 45.6 46.3 44.8 51.9 34.6 42.1 42.1 42.1 42.1 48.2 33.0
80 49.7 49.7 53.1 41.0 57.8 30.1 46.7 46.7 50.1 40.0 55.3 28.8 43.3 43.3 46.2 38.3 52.3 27.4 39.7 39.7 41.8 36.3 48.7 25.9
85 52.8 52.8 53.8 49.7 58.1 37.7 50.3 50.3 51.0 49.1 55.6 37.0 47.2 47.2 47.2 47.2 52.5 36.1 43.7 43.7 43.7 43.7 48.9 34.9
90 55.5 55.5 55.5 55.5 58.7 45.3 53.4 53.4 53.4 53.4 56.1 45.2 50.7 50.7 50.7 50.7 53.1 44.7 47.6 47.6 47.6 47.6 49.5 43.8
75 48.2 45.8 53.3 33.4 57.8 21.3 44.4 43.8 50.4 32.1 55.4 20.0 40.3 40.3 46.5 30.4 52.5 18.6 36.6 36.6 41.9 28.3 49.0 17.2
80
51.0 51.0 53.7 42.7 58.3 31.1 48.1 48.1 50.7 41.9 55.7 29.6 44.7 44.7 47.0 40.3 52.8 28.4 41.1 41.1 42.6 38.3 49.2 26.9
1920
85 53.9 53.9 54.6 51.8 58.6 38.7 51.6 51.6 51.9 51.5 56.2 38.4 48.6 48.6 48.6 48.6 53.1 37.7 45.2 45.2 45.2 45.2 49.4 36.6
90 56.6 56.6 56.6 56.6 59.3 47.0 54.6 54.6 54.5 54.5 56.8 47.1 52.0 52.0 52.0 52.0 53.8 46.9 49.0 49.0 49.0 49.0 50.3 46.1
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
Table PD-4 — Gross Cooling Capacities (MBH) 5 Ton Single/Three Phase TSC060A1, A3, A4, AW, AK
AmbientTemperature (F)
85
95
105
115
Enter.
Dry
Bulb
EnteringWet Bulb (F)
73
CFM
6 1
67
73
61
67
61
67
73
61
67
73
Airflow
(F)
MBH
SHC
MBH
SHC
MBH
SHC
MBH
SHC
MBH
SHC
MBH
SHC
MBH
SHC
75
MBH
SHC
MBH
SHC
MBH
SHC
MBH
SHC
MBH
SHC
57.4 49.1 64.8 37.9 69.2 25.3 53.3 47.0 61.8 36.3 67.2 24.1 49.4 45.0 57.6 34.3 64.3 22.8 45.2 42.9 52.4 32.7 60.6 21.2
80 59.0 59.0 65.1 47.1 69.8 35.0 55.6 55.6 62.0 45.7 67.6 33.8 52.2 52.2 57.8 43.9 64.6 32.3 48.6 48.6 52.8 41.6 60.8 30.6
85 63.1 63.1 65.7 56.2 70.2 42.9 60.3 60.3 62.7 55.3 68.0 42.3 56.8 56.8 58.9 53.6 64.9 41.3 52.9 52.9 54.0 51.4 61.0 39.9
90 66.4 66.4 66.9 65.2 70.8 51.0 64.1 64.1 64.1 64.1 68.5 50.8 61.1 61.1 61.1 61.1 65.4 50.1 57.5 57.5 57.5 57.5 61.5 49.0
75 59.0 52.2 65.7 39.4 69.8 25.7 54.9 50.1 62.8 37.9 67.8 24.6 50.7 48.0 58.9 36.1 64.9 23.2 46.5 45.9 53.5 33.8 61.3 21.6
80 61.3 61.3 66.0 49.2 70.2 35.6 58.1 58.1 63.1 48.2 68.1 34.8 54.4 54.4 59.2 46.6 65.3 33.7 50.6 50.6 54.0 44.3 61.5 32.0
85 65.1 65.1 66.8 59.1 70.9 44.2 62.5 62.5 64.0 58.5 68.7 43.8 59.3 59.3 60.4 57.3 65.7 43.1 55.2 55.2 55.8 55.2 61.8 41.9
90 68.1 68.1 68.0 68.0 71.6 52.9 65.9 65.9 65.9 65.9 69.4 52.9 63.1 63.1 63.1 63.1 66.3 52.5 59.7 59.7 59.7 59.7 62.4 51.7
75 60.3 55.2 66.3 40.6 70.2 26.1 56.3 53.1 63.6 39.5 68.2 25.0 52.0 51.0 59.9 37.8 65.4 23.6 47.7 47.7 54.5 35.4 61.8 22.0
80 63.1 63.1 66.8 51.2 70.8 37.9 60.2 60.2 64.0 50.5 68.7 35.6 56.5 56.5 60.3 49.1 65.8 34.6 52.4 52.4 55.2 46.9 62.1 33.3
85 66.5 66.5 67.7 61.6 71.5 45.4 64.2 64.2 65.0 61.3 69.4 45.2 61.2 61.2 61.7 60.5 66.4 44.7 57.3 57.3 57.3 57.3 62.5 43.8
90 69.4 69.4 69.3 69.3 72.2 54.6 67.3 67.3 67.3 67.3 70.1 54.9 64.6 64.6 64.6 64.6 67.1 54.8 61.2 61.2 61.2 61.2 63.2 54.2
1800
2000
2200
75 61.5 58.0 66.9 41.8 70.6 26.5 57.6 56.0 64.2 40.8 68.6 25.4 53.0 53.0 60.6 39.3 65.9 24.0 49.1 49.1 55.4 37.1 62.2 22.4
80 64.5 64.5 67.5 53.0 71.2 38.8 61.8 61.8 64.7 52.5 69.1 36.4 58.3 58.3 61.1 51.4 66.3 35.5 53.9 53.9 56.3 49.5 62.5 34.3
2400
85
67.7 67.7 68.5 63.9 72.0 46.5 65.4 65.4 65.9 63.9 69.9 46.5 62.5 62.5 62.5 62.5 66.9 46.2 58.9 58.9 58.9 58.9 63.0 45.5
90 70.4 70.4 70.4 70.4 72.8 56.1 68.4 68.4 68.4 68.4 70.6 56.6 65.8 65.8 65.8 65.8 67.7 56.8 62.4 62.4 62.4 62.4 63.9 56.5
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
RT-PRC005-EN
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(6, 7½Ton)
Standard Efficiency
Table PD-5 — Gross Cooling Capacities (MBH) 6 Ton Three Phase TSC072A3, A4, AW, AK
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 65.9 55.0 73.4 43.5 76.7 28.3 61.0 52.5 70.7 40.9 75.4 27.3 56.3 50.1 66.3 38.8 73.2 26.0 51.7 47.7 60.9 36.4 70.3 24.6
80
85
67.6 66.2 73.7 52.2 77.5 38.9 63.2 63.2 70.9 51.1 76.0 37.8 59.2 59.2 66.4 49.1 73.7 36.4 55.3 55.3 61.0 46.6 70.6 34.9
71.4 71.4 74.2 61.9 78.6 47.4 68.5 68.5 71.4 61.3 76.5 46.6 64.4 64.4 67.3 59.7 74.0 46.0 60.4 60.4 62.2 57.3 70.8 45.0
2160
2400
2640
90 74.6 74.6 75.3 71.3 79.3 55.7 72.4 72.4 72.8 71.3 77.2 55.5 69.5 69.5 69.5 69.5 74.6 55.4 65.7 65.7 65.6 65.6 71.2 54.8
75 67.7 58.3 74.0 43.8 77.1 28.7 62.9 55.9 71.7 42.6 75.9 27.7 57.9 53.4 67.9 40.8 73.7 26.4 53.2 51.0 62.4 38.3 70.9 25.0
80 69.7 69.7 74.6 54.1 78.0 39.5 66.2 66.2 72.0 53.6 76.6 39.2 61.8 61.8 68.0 52.0 74.3 37.9 57.8 57.8 62.6 49.6 71.3 36.3
85 73.4 73.4 75.3 64.5 79.0 48.2 70.9 70.9 72.7 64.5 77.2 47.9 67.4 67.4 69.1 63.6 74.8 47.6 63.2 63.2 64.2 61.4 71.7 47.0
90 76.2 76.2 76.5 74.3 79.9 57.1 74.3 74.3 74.3 74.3 77.9 57.4 71.7 71.7 71.7 71.7 75.5 57.7 68.5 68.5 68.4 68.4 72.2 57.5
75 69.1 61.4 74.7 44.9 77.4 29.0 64.5 59.1 72.5 44.3 76.2 28.1 59.4 56.6 69.0 42.5 74.2 26.9 54.7 54.2 63.6 40.1 71.3 25.4
80
85 74.8 74.8 76.1 66.8 79.4 49.1 72.7 72.7 73.8 67.3 77.8 49.3 69.7 69.7 70.5 66.9 75.4 49.1 65.7 65.7 66.1 65.4 72.3 48.7
90 77.4 77.4 77.5 76.8 80.3 58.4 75.8 75.8 75.8 75.8 78.5 59.0 73.4 73.4 73.3 73.3 76.2 59.7 70.5 70.5 70.5 70.5 73.0 59.8
71.6 71.6 75.3 55.8 78.4 40.0 68.6 68.6 72.8 55.8 77.0 41.1 64.2 64.2 69.1 54.7 74.6 38.6 60.0 60.0 63.9 52.4 71.9 37.7
75 70.2 64.1 75.2 45.8 77.6 29.4 66.1 62.3 73.1 45.4 76.5 28.5 60.9 59.7 69.8 44.2 74.5 27.3 56.2 56.2 64.7 41.9 71.7 25.8
80 72.9 72.9 75.9 57.4 78.7 40.4 70.3 70.3 73.6 57.8 77.3 41.8 66.5 66.5 70.1 57.1 75.2 41.1 62.0 62.0 65.2 55.2 72.1 38.5
85 75.9 75.9 76.8 68.8 79.7 49.9 74.0 74.0 74.7 69.8 78.5 50.6 71.3 71.3 71.6 69.8 75.9 50.4 67.8 67.8 67.7 67.7 72.9 50.1
90 78.3 78.3 78.3 78.3 80.7 59.6 76.8 76.8 76.8 76.8 79.0 60.5 74.6 74.6 74.6 74.6 76.7 61.6 71.9 71.9 71.9 71.9 73.7 61.9
2880
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC=SensibleHeatCapacity
Table PD-6 — Gross Cooling Capacities (MBH) 7½Ton Three Phase Single Compressor TSC090A3, A4, AW, AK
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 87.4 73.8 96.2 56.7 98.8 36.7 80.6 70.3 93.3 54.3 98.8 35.6 73.5 66.6 86.9 51.2 96.8 33.9 66.6 63.1 78.4 48.2 92.8 31.8
80 89.6 88.9 96.6 68.7 100.0 49.9 83.4 83.4 93.5 68.3 99.9 50.2 77.6 77.6 87.2 65.3 97.4 48.2 71.6 71.6 78.9 61.5 92.9 46.0
85 94.2 94.2 97.5 81.6 101.2 60.4 90.4 90.4 94.4 82.2 100.9 61.9 84.8 84.8 88.5 79.8 97.8 61.4 78.5 78.5 80.7 76.2 93.2 59.9
90 98.0 98.0 98.7 93.9 102.3 71.0 95.8 95.8 96.2 95.8 101.2 72.9 91.6 91.6 91.6 91.6 98.5 74.3 86.0 86.0 86.0 86.0 93.7 73.5
75 89.7 78.4 96.7 57.3 99.1 37.2 83.0 75.0 94.6 56.7 99.2 36.1 75.8 71.3 88.9 53.9 97.5 34.5 68.7 67.7 80.3 50.1 93.8 32.5
80 92.2 92.2 97.5 70.9 100.3 50.4 87.4 87.4 95.0 71.8 100.4 50.9 81.4 81.4 89.3 69.5 98.3 50.3 75.0 75.0 81.1 65.8 94.1 48.1
85 96.5 96.5 98.5 84.4 101.5 61.2 93.8 93.8 96.1 86.6 101.6 63.4 88.9 88.9 91.0 85.5 98.8 63.7 82.5 82.5 83.7 82.1 94.4 63.1
90 99.5 99.5 99.9 97.0 102.6 72.3 98.2 98.2 98.2 98.2 101.9 75.0 94.9 94.9 94.9 94.9 99.7 77.4 90.1 90.1 90.0 90.0 95.3 77.7
2700
3000
3300
75
91.5 82.5 97.7 59.0 99.3 37.7 85.2 79.6 95.5 58.8 99.5 36.6 78.0 76.0 90.5 56.5 98.0 35.1 70.5 70.5 82.1 52.8 94.5 33.2
80 94.4 94.4 98.1 72.8 100.5 55.0 90.7 90.7 96.2 74.8 100.8 51.6 84.7 84.7 91.1 73.5 98.9 51.5 78.0 78.0 83.2 70.0 95.0 50.1
85 98.0 98.0 99.2 86.8 101.7 62.0 96.1 96.1 97.5 90.5 102.0 64.7 92.0 92.0 93.1 90.6 99.5 65.6 86.2 86.2 86.2 86.2 95.4 65.8
90 100.5 100.5 100.7 99.4 102.8 73.4 99.9 99.9 99.9 99.9 102.4 76.8 97.2 97.2 97.2 97.2 100.5 80.1 93.0 93.0 93.0 93.0 96.5 81.4
75 92.9 86.2 98.1 59.9 99.4 38.2 87.3 84.1 96.3 60.6 99.8 37.2 79.6 79.6 91.7 58.9 98.3 35.7 72.9 72.9 83.7 55.4 95.1 33.8
80 96.0 96.0 98.6 74.3 100.7 56.8 93.1 93.1 97.1 77.5 101.0 55.7 87.6 87.6 92.5 77.2 99.5 52.7 80.7 80.7 85.1 74.1 95.5 51.6
85 99.0 99.0 99.7 88.7 101.8 62.7 97.8 97.8 98.6 93.7 102.3 65.8 94.4 94.4 94.4 94.4 100.0 67.3 89.1 89.1 89.1 89.1 96.3 68.3
90 101.1 101.1 101.1 101.1 103.0 74.4 101.0 101.0 101.0 101.0 102.8 78.4 98.9 98.9 98.9 98.9 101.2 82.4 95.1 95.1 95.1 95.1 97.5 84.6
3600
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC=SensibleHeatCapacity
RT-PRC005-EN
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(7½, 8½Ton)
Standard Efficiency
Table PD-7 — Gross Cooling Capacities (MBH) 7½Ton Three Phase Dual Compressors TSC092A3, A4, AW
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 84.6 72.9 93.9 55.3 98.4 36.4 78.2 69.6 90.1 53.3 96.9 35.1 71.8 66.3 83.9 50.4 94.0 33.3 65.3 63.1 76.5 47.1 89.4 31.2
80 86.8 86.8 94.4 68.5 99.6 50.0 81.8 81.8 90.5 67.5 98.0 49.7 76.4 76.4 84.3 64.7 94.5 47.5 70.9 70.9 77.1 61.4 89.6 45.3
85 92.2 92.2 95.4 81.7 100.8 61.3 88.4 88.4 91.5 81.5 99.0 62.4 83.2 83.2 85.8 79.3 94.9 60.9 77.6 77.6 79.0 76.1 89.9 59.3
90 96.3 96.3 96.9 94.4 102.0 72.8 93.6 93.6 93.6 93.6 99.3 73.4 89.6 89.6 89.6 89.6 95.8 74.0 84.5 84.5 84.5 84.5 90.6 73.0
75 86.8 77.5 94.7 57.0 98.9 37.1 80.5 74.4 91.5 55.8 97.6 35.7 74.0 71.1 85.6 53.1 94.8 34.0 67.1 67.1 78.2 49.8 90.5 31.9
80 90.1 90.1 95.6 71.2 100.2 50.8 85.4 85.4 92.0 71.1 98.7 50.7 79.9 79.9 86.3 68.9 95.5 49.6 74.1 74.1 79.1 65.7 90.8 47.4
85 94.7 94.7 96.8 85.3 101.4 62.7 91.5 91.5 93.3 86.2 99.7 63.7 86.9 86.9 88.2 84.9 96.1 63.5 81.3 81.3 81.2 81.2 91.2 62.6
90 98.3 98.3 98.3 98.3 102.7 74.8 96.2 96.2 96.1 96.1 100.3 76.2 92.7 92.7 92.7 92.7 97.1 77.5 88.0 88.0 88.0 88.0 92.2 77.4
75 88.7 81.9 95.7 58.9 99.3 37.6 82.6 79.0 92.5 58.2 98.1 36.2 75.5 75.5 87.1 55.7 95.4 34.6 69.6 69.6 79.6 52.4 91.3 32.5
80 92.3 92.3 96.5 73.7 100.7 51.5 88.4 88.4 93.2 74.4 99.3 51.7 82.9 82.9 87.9 72.8 96.1 51.0 76.9 76.9 80.8 69.8 91.7 49.5
85 96.5 96.5 97.8 88.4 102.0 63.9 93.8 93.8 94.8 90.3 100.0 65.0 89.8 89.8 89.8 89.8 96.9 65.8 84.4 84.4 84.4 84.4 92.3 65.5
90 99.7 99.7 99.7 99.7 103.3 76.5 98.0 98.0 98.0 98.0 101.1 78.5 94.9 94.9 94.9 94.9 98.1 80.6 90.7 90.7 90.7 90.7 93.5 81.3
2700
3000
3300
75 90.2 85.7 96.4 60.6 99.7 38.1 84.6 83.6 93.3 60.0 98.5 36.8 77.9 77.9 88.2 58.1 96.0 35.2 71.8 71.8 80.9 55.0 92.0 33.2
80 94.0 94.0 97.2 75.8 101.0 52.1 90.7 90.7 94.3 77.4 99.7 52.6 85.6 85.6 89.2 76.6 96.6 52.0 79.5 79.5 82.3 73.8 92.5 51.5
3600
85
97.8 97.8 98.7 91.1 102.4 65.0 95.6 95.6 96.1 93.9 100.5 66.3 91.9 91.9 91.9 91.9 97.6 67.9 86.9 86.9 86.9 86.9 93.1 68.2
90 100.8 100.8 100.8 100.8 103.7 78.1 99.3 99.3 99.3 99.3 101.7 80.7 96.6 96.6 96.6 96.6 98.9 83.4 92.7 92.7 92.7 92.7 94.6 84.9
NOTES:
1.
2.
3.
Allcapacitiesshownaregrossandhavenotconsideredindoorfanheat.Toobtainnetcoolingsubtractindoorfanheat.
MBH = Total Gross Capacity
SHC = Sensible Heat Capacity
Table PD-8 — Gross Cooling Capacities (MBH) 8½Ton Three Phase TSC102A3, A4, AW, AK
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 96.3 82.3 106.6 62.7 112.5 41.5 89.0 78.5 103.2 60.6 110.9 40.0 81.8 74.9 96.6 57.5 107.6 38.1 74.9 71.3 87.6 55.2 102.5 35.8
80 98.0 98.0 107.2 77.1 113.7 57.0 92.9 91.4 103.4 76.3 111.5 57.1 86.3 86.2 96.9 73.3 108.2 54.0 80.2 80.2 88.1 69.4 102.8 51.5
85 103.9 103.9 108.1 91.7 114.8 69.6 100.1 100.1 104.3 91.7 112.4 70.0 94.3 94.3 98.3 89.5 108.6 68.9 87.6 87.6 89.9 85.7 103.1 67.1
90 108.6 108.6 109.6 105.7 116.0 82.4 105.9 105.9 105.9 105.9 113.2 83.0 101.6 101.6 101.9 100.2 109.3 83.4 95.6 95.6 95.6 95.5 103.6 82.3
75 98.7 87.2 107.8 65.9 113.0 42.0 91.8 83.8 104.7 63.7 111.8 40.7 84.2 80.0 98.7 60.5 108.6 38.9 76.3 76.3 89.6 58.6 103.7 36.5
80 101.6 100.0 108.5 80.1 114.6 58.1 96.9 96.5 105.0 80.1 112.8 57.8 90.3 90.3 99.1 77.9 109.3 56.3 83.8 83.8 90.3 74.0 104.0 53.8
85 106.8 106.8 109.6 95.7 115.8 71.4 103.6 103.6 106.2 96.7 114.0 70.7 98.7 98.7 100.9 95.5 109.8 71.7 91.7 91.7 91.7 91.7 104.3 70.7
90 111.0 111.0 111.0 111.0 117.0 84.9 108.8 108.8 108.9 107.2 114.4 86.1 105.1 105.1 105.0 104.8 110.7 87.4 99.8 99.8 99.7 99.7 105.2 87.1
75 100.7 91.7 109.2 64.5 114.0 42.8 93.8 88.7 106.1 66.5 113.5 41.7 85.4 85.4 100.4 63.3 109.4 39.6 79.4 77.5 91.3 59.4 104.6 37.2
80 104.1 103.6 109.6 82.9 115.3 59.0 100.0 100.0 106.6 84.3 113.7 59.0 94.0 94.0 100.9 82.2 109.6 60.2 87.0 87.0 92.2 78.5 105.1 56.0
85 108.9 108.9 110.9 99.2 116.6 73.0 106.7 106.7 108.3 102.4 114.8 74.4 102.0 102.0 102.0 102.0 110.8 74.3 95.6 95.6 96.4 93.7 105.5 73.9
90 112.8 112.8 112.8 112.8 117.8 87.2 111.8 111.8 111.8 111.2 116.0 90.0 107.7 107.7 107.7 107.7 111.9 90.9 102.9 102.9 102.9 102.9 106.6 91.4
75 102.3 95.8 110.2 66.1 114.6 43.5 95.2 95.2 106.7 68.3 113.1 42.2 88.2 88.2 101.6 65.9 110.1 40.3 81.6 80.6 92.7 62.1 105.3 38.1
80 106.2 106.2 110.5 85.3 115.9 59.8 102.8 102.8 107.4 86.8 114.3 60.0 97.4 97.4 102.4 86.2 111.0 58.6 89.9 89.9 94.1 82.9 105.9 58.2
85 110.5 110.5 111.9 102.3 117.2 74.4 108.3 108.3 109.2 105.1 115.5 76.3 104.5 104.5 104.4 104.4 111.5 77.2 98.7 98.7 99.0 97.4 106.4 76.8
90 114.2 114.2 114.2 114.2 118.5 89.3 112.7 112.7 112.7 112.7 116.8 92.7 109.7 109.7 109.7 109.7 112.9 94.2 105.2 105.2 105.2 105.2 107.8 95.4
3060
3400
3740
4080
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC=SensibleHeatCapacity
RT-PRC005-EN
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(10 Ton)
Standard Efficiency
Table PD-9 — Gross Cooling Capacities (MBH) 10 Ton Three Phase TSC120A3, A4, AW, AK
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 109.2 95.1 119.3 71.0 123.3 46.1 101.7 91.5 115.7 69.0 122.1 44.6 93.2 87.4 108.3 66.1 119.9 42.8 84.9 83.4 99.6 62.4 114.5 40.4
80 112.4 112.4 119.9 86.9 124.6 64.8 106.9 106.9 116.3 87.4 123.4 63.2 99.8 99.8 109.3 84.9 120.2 61.3 92.8 92.8 100.9 81.3 115.0 58.9
85 118.2 118.2 121.2 103.4 126.2 76.0 114.6 114.6 117.7 105.2 124.9 77.6 108.7 108.7 111.4 104.0 121.3 78.1 102.2 102.2 103.6 100.5 115.5 77.0
90 122.6 122.6 122.9 119.0 127.7 89.9 120.1 120.1 120.1 120.1 126.3 93.0 116.2 116.2 116.2 116.2 122.7 94.7 110.7 110.7 110.7 110.7 116.6 94.3
75 112.0 101.1 120.4 72.8 123.8 46.9 104.9 98.0 117.1 72.3 122.7 45.3 96.5 94.0 111.0 70.0 120.0 43.5 87.7 87.7 102.0 66.1 115.5 41.2
80 115.8 115.8 121.6 90.8 125.3 63.0 111.4 111.4 118.0 91.7 124.1 63.4 104.9 104.9 112.2 90.7 121.3 63.4 97.3 97.3 103.5 87.0 116.2 61.7
85 120.6 120.6 123.1 108.3 126.9 77.4 118.0 118.0 119.7 110.5 125.6 79.5 113.4 113.4 114.4 110.9 121.9 80.1 106.7 106.7 106.7 106.7 116.9 80.7
90 124.5 124.5 124.9 124.9 128.4 91.9 122.9 122.9 122.6 122.6 127.2 95.7 119.3 119.3 119.3 119.3 123.3 97.3 114.3 114.3 114.3 114.3 118.3 99.2
75 114.1 106.4 120.6 73.7 124.2 47.6 107.6 104.3 118.2 75.6 123.1 46.1 99.0 99.0 112.7 73.4 120.6 44.2 91.1 91.1 103.8 69.7 116.3 42.0
80 118.2 118.2 121.9 92.4 125.8 63.8 114.7 114.7 119.3 95.4 124.7 64.4 108.7 108.7 114.0 95.7 122.0 64.9 101.4 101.4 105.7 92.5 117.0 64.1
85 122.7 122.7 123.5 110.4 127.4 78.7 120.3 120.3 121.2 115.0 126.2 81.3 116.3 116.3 116.3 116.3 122.7 82.5 110.6 110.6 110.6 110.6 118.0 84.0
90 125.4 125.4 125.4 125.4 129.0 93.8 124.7 124.7 124.2 124.2 127.9 98.0 121.5 121.5 121.5 121.5 124.3 100.5 117.0 117.0 117.0 117.0 119.6 103.4
75 115.7 111.0 121.3 75.4 124.6 48.3 109.5 109.5 119.1 77.3 123.5 46.8 102.3 102.3 114.0 76.7 121.0 45.0 94.2 94.2 105.4 73.3 116.8 42.8
80 119.8 119.8 122.8 94.9 126.3 64.5 117.0 117.0 120.3 98.7 125.1 65.4 112.0 112.0 115.5 100.1 122.5 66.1 104.7 104.7 107.7 98.0 117.7 66.0
85 123.7 123.7 124.4 113.4 127.9 80.0 121.9 121.9 122.4 118.8 126.7 82.9 118.5 118.5 118.5 118.5 124.0 85.7 113.2 113.2 113.3 113.3 119.0 87.2
90 126.4 126.4 126.5 126.5 129.5 95.6 125.6 125.6 125.4 125.4 128.4 100.2 123.7 123.7 122.9 122.9 125.8 104.8 118.9 118.9 118.9 118.9 120.8 107.5
3600
4000
4400
4800
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC=SensibleHeatCapacity
RT-PRC005-EN
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(3, 4Ton)
High Efficiency
Table PD-10 — Gross Cooling Capacities (MBH) 3 Ton THC036A1, A3, A4, AW
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
CFM
Bulb
61
67
73
61
67
73
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 34.2 29.2 39.8 22.7 43.1 15.2 31.1 27.4 37.0 21.2 41.3 14.1 28.0 25.7 33.3 19.8 39.0 12.9 24.8 24.0 29.8 18.1 36.1 11.6
80 34.9 34.9 40.0 28.5 43.5 21.3 32.3 32.3 37.1 27.1 41.6 20.1 29.7 29.7 33.5 25.3 39.2 18.8 27.1 27.1 30.0 23.6 36.2 17.5
1080
1200
1320
85
37.9 37.9 40.3 34.3 44.0 26.5 35.3 35.3 37.5 33.0 41.9 25.6 32.6 32.6 34.0 31.3 39.5 24.6 30.0 30.0 30.6 29.6 36.4 23.2
90 40.5 40.5 40.9 40.0 44.5 31.7 38.4 38.4 38.4 38.4 42.3 31.0 35.7 35.7 35.7 35.7 39.7 30.3 32.9 32.9 32.9 32.9 36.7 29.0
75 35.3 31.2 40.4 23.7 43.5 15.5 32.0 29.4 37.8 22.4 41.8 14.4 28.8 27.7 34.1 20.6 39.5 13.2 25.5 25.5 30.5 18.8 36.7 11.9
80 36.7 36.7 40.7 30.0 44.0 21.9 33.9 33.9 38.0 28.9 42.1 20.9 31.2 31.2 34.4 27.1 39.8 19.7 28.5 28.5 30.8 25.3 36.9 18.4
85 39.6 39.6 41.1 36.3 44.6 27.4 37.1 37.1 38.5 35.4 42.5 26.8 34.3 34.3 35.1 33.8 40.0 26.0 31.5 31.5 31.5 31.5 37.1 24.8
90
41.9 41.9 41.9 41.9 45.1 33.0 39.9 39.9 39.9 39.9 42.9 32.6 37.6 37.6 37.6 37.6 40.4 32.1 34.7 34.7 34.7 34.7 37.4 31.1
75 36.2 33.2 40.9 24.7 43.8 15.8 32.8 31.4 38.4 23.4 42.1 14.7 29.4 29.4 34.8 21.7 39.9 13.5 26.5 26.5 31.0 19.9 37.2 12.2
80 38.2 38.2 41.2 31.4 44.4 22.4 35.4 35.4 38.7 30.5 42.6 21.7 32.5 32.5 35.2 28.9 40.2 20.5 29.7 29.7 31.5 27.1 37.4 19.2
85 40.8 40.8 41.8 38.1 45.0 28.3 38.7 38.7 39.4 37.6 43.1 28.0 35.9 35.9 36.2 36.2 40.5 27.2 32.9 32.9 32.9 32.9 37.6 26.2
90 42.9 42.9 42.9 42.9 45.6 34.2 41.1 41.1 41.1 41.1 43.4 34.0 38.9 38.9 38.9 38.9 41.0 33.8 36.3 36.3 36.3 36.3 38.1 33.1
75
80 39.4 39.4 41.7 32.6 44.7 22.9 36.8 36.8 39.3 32.1 42.9 22.3 33.8 33.8 35.9 30.6 40.6 21.4 30.8 30.8 32.1 28.8 37.8 20.1
85 41.7 41.7 42.4 39.7 45.3 29.0 39.8 39.8 40.1 39.5 43.5 29.0 37.3 37.3 37.3 37.3 40.9 28.3 34.2 34.2 34.2 34.2 38.0 27.6
90 43.7 43.7 43.7 43.7 45.9 35.3 42.1 42.1 42.1 42.1 43.9 35.3 40.0 40.0 40.0 40.0 41.5 35.4 37.5 37.5 37.5 37.5 38.6 34.9
37.1 35.1 41.3 25.5 44.1 16.1 33.6 33.3 38.9 24.4 42.4 15.0 30.4 30.4 35.5 22.8 40.2 13.8 27.5 27.5 31.5 21.0 37.5 12.5
1440
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
Table PD-11 — Gross Cooling Capacities (MBH) 4Ton THC048A1, A3, A4, AW
AmbientTemperature (F)
85
95
105
67
115
67
Enter.
Dry
EnteringWet Bulb (F)
73 61
CFM
Bulb
61
67
73
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 45.3 39.9 51.4 30.3 54.9 19.9 41.1 37.7 48.4 28.8 53.1 18.7 37.1 35.6 43.9 26.7 51.0 17.4 33.2 33.2 39.3 24.6 47.8 16.0
80
47.1 47.1 52.0 38.4 55.5 28.1 43.8 43.8 48.7 36.9 54.6 27.2 40.3 40.3 44.3 34.9 51.3 25.6 36.9 36.9 39.8 32.8 47.9 24.1
1440
1600
1760
85 50.5 50.5 52.5 46.3 56.2 34.5 47.8 47.8 49.4 45.2 54.9 34.9 44.3 44.3 45.3 43.3 51.6 33.6 40.9 40.9 40.9 40.9 48.1 32.2
90 53.1 53.1 53.5 53.5 56.9 41.4 51.2 51.2 51.2 51.2 54.6 41.4 48.4 48.4 48.4 48.4 52.0 41.2 45.0 45.0 45.0 45.0 48.6 40.2
75 46.7 42.7 52.7 31.9 55.2 20.2 42.4 40.5 49.4 30.3 54.4 19.3 38.2 38.2 45.0 28.4 51.6 17.8 34.7 34.7 40.2 26.2 48.6 16.4
80 49.2 49.2 52.8 40.4 55.9 28.2 46.0 46.0 49.8 39.4 55.2 28.4 42.3 42.3 45.6 37.5 51.9 26.9 38.7 38.7 40.9 35.3 48.7 25.4
85 52.1 52.1 53.5 48.8 56.6 35.4 49.9 49.9 50.6 48.3 55.7 36.8 46.7 46.7 47.0 46.8 52.2 35.2 43.0 43.0 42.9 42.9 49.0 34.3
90 54.5 54.5 54.8 54.8 57.4 42.7 52.8 52.8 52.8 52.8 55.2 42.9 50.5 50.5 50.5 50.5 52.9 43.5 47.4 47.4 47.4 47.4 49.6 43.0
75
47.8 45.4 53.2 33.4 55.5 20.6 43.7 43.3 50.1 31.8 54.7 19.6 39.7 39.7 46.0 30.0 51.9 18.2 36.1 36.1 41.0 27.7 49.1 16.8
80 50.6 50.6 53.4 42.1 56.2 28.7 47.8 47.8 50.5 41.5 55.7 29.4 44.1 44.1 46.7 39.9 52.4 28.1 40.4 40.4 41.9 37.8 49.3 26.7
85 53.1 53.1 54.2 50.9 57.0 36.2 51.4 51.4 51.6 51.0 56.2 38.0 48.6 48.6 48.6 48.6 52.8 36.7 44.9 44.9 44.9 44.9 49.7 36.3
90 55.1 55.1 55.7 55.7 57.7 43.8 53.9 53.9 53.9 53.9 55.6 44.3 51.9 51.9 51.9 51.9 53.5 45.6 49.2 49.2 49.2 49.2 50.5 45.7
75 48.8 48.1 53.6 34.4 55.7 20.9 45.0 45.0 50.6 33.2 55.0 20.0 41.0 41.0 46.8 31.5 52.3 18.5 37.3 37.3 41.7 29.3 49.6 17.2
80
51.7 51.7 53.9 43.5 56.4 31.7 49.3 49.3 51.2 43.5 56.0 30.1 45.8 45.8 47.6 42.3 52.8 28.9 41.8 41.8 42.8 40.2 49.8 27.9
1920
85 53.9 53.9 54.8 52.7 57.2 36.9 52.4 52.4 52.4 52.4 56.5 39.1 50.0 50.0 50.0 50.0 53.2 38.1 46.6 46.6 46.6 46.6 50.3 38.1
90 55.7 55.7 56.3 56.3 58.0 44.8 54.7 54.7 54.7 54.7 56.0 45.6 53.0 53.0 53.0 53.0 54.0 47.4 50.5 50.5 50.5 50.5 51.2 48.1
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
RT-PRC005-EN
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(5Ton)
High Efficiency
Table PD-12 — Gross Cooling Capacities (MBH) 5 Ton Single Phase THC060A1
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
CFM
Bulb
61
67
73
61
67
73
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 56.2 48.2 64.3 37.8 68.4 24.8 51.4 45.6 60.5 35.2 66.7 23.5 46.8 43.2 55.3 32.8 63.9 21.9 42.2 40.8 50.0 31.0 59.9 20.1
80
57.6 57.6 64.6 46.6 69.3 34.7 53.7 53.7 60.7 44.8 67.3 33.1 49.8 49.8 55.5 42.3 64.2 31.5 45.9 45.9 50.5 39.9 60.1 29.6
1800
2000
2200
85 62.2 62.2 65.2 55.8 70.1 42.6 58.4 58.4 61.4 54.5 68.0 42.2 54.5 54.5 56.5 52.0 64.6 40.9 50.6 50.6 51.6 49.7 60.3 39.0
90 65.8 65.8 66.3 64.9 70.9 50.8 63.0 63.0 63.0 63.0 68.2 52.0 59.3 59.3 59.2 59.2 65.0 49.9 55.3 55.3 55.3 55.3 60.7 48.5
75
80 60.3 60.3 65.6 48.8 69.8 35.2 56.2 56.2 62.1 47.6 68.0 34.6 52.1 52.1 56.9 45.1 65.0 32.9 48.1 48.1 51.7 42.7 61.2 31.1
85 64.4 64.4 66.3 58.7 70.7 43.8 61.2 61.2 63.0 58.1 68.7 43.9 57.1 57.1 58.2 56.0 65.4 42.8 53.0 53.0 53.0 53.0 61.4 41.5
90
75 59.4 54.5 65.7 40.1 69.3 25.6 54.3 51.9 62.7 38.7 67.7 24.3 49.6 49.4 57.6 36.3 65.1 22.8 45.0 45.0 52.2 33.8 61.6 21.1
80 62.4 62.4 66.3 50.7 70.3 35.8 58.4 58.4 63.1 50.1 68.5 35.4 54.2 54.2 58.2 47.9 65.7 34.2 50.0 50.0 52.9 45.4 61.9 32.5
85 66.0 66.0 67.3 61.2 71.2 44.8 63.3 63.3 64.2 61.3 69.4 45.3 59.4 59.4 59.9 59.8 66.1 44.6 55.2 55.2 55.2 55.2 62.2 43.7
90 68.9 68.9 68.9 68.9 72.2 54.0 66.9 66.9 66.9 66.9 70.2 55.4 64.0 64.0 64.0 64.0 66.8 55.1 60.4 60.4 60.4 60.4 63.0 54.6
57.8 51.4 65.2 38.8 69.6 25.4 52.9 48.8 61.8 37.0 67.3 23.9 48.2 46.3 56.5 34.6 64.6 22.4 43.3 43.3 51.2 32.1 60.9 20.7
67.6 67.6 67.6 67.6 71.6 52.5 65.2 65.2 65.2 65.2 69.5 53.3 62.0 62.0 62.0 62.0 66.0 52.6 58.0 58.0 58.0 58.0 62.0 51.8
75 60.6 57.4 66.1 41.5 69.7 26.0 55.6 54.9 63.4 40.3 68.1 24.7 50.8 50.8 58.5 38.0 65.5 23.2 46.5 46.5 53.0 35.5 62.1 21.5
80 64.0 64.0 67.0 52.5 70.6 38.5 60.4 60.4 63.9 52.4 69.0 36.1 56.1 56.1 59.2 50.5 66.1 35.8 51.8 51.8 54.0 48.1 62.5 33.8
2400
85
67.2 67.2 68.0 63.5 71.5 50.9 64.9 64.9 65.3 64.2 69.9 46.6 61.4 61.4 61.4 61.4 67.0 46.8 57.2 57.2 57.2 57.2 62.9 45.6
90 69.8 69.8 69.8 69.8 72.6 55.3 68.1 68.1 68.1 68.1 70.8 57.1 65.5 65.5 65.5 65.5 67.5 57.3 62.2 62.2 62.2 62.2 63.9 57.2
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
Table PD-13 — Gross Cooling Capacities (MBH) 5Ton Three Phase THC060A3, A4, AW
AmbientTemperature (F)
85
95
105
67
115
67
Enter.
Dry
EnteringWet Bulb (F)
73 61
CFM
Bulb
61
67
73
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 56.6 49.0 64.4 37.5 67.7 24.7 52.0 46.8 60.9 35.7 66.2 23.3 47.0 44.2 55.9 33.3 63.6 21.8 42.3 41.7 50.0 30.7 59.8 20.0
80 58.5 58.5 64.6 47.0 68.6 34.7 54.7 54.7 61.2 45.5 66.8 33.3 50.6 50.6 56.3 43.2 64.1 31.7 46.4 46.4 50.5 40.5 60.0 29.8
85 62.9 62.9 65.3 56.4 69.4 42.2 59.6 59.6 61.9 55.5 67.7 42.3 55.6 55.6 57.3 53.2 64.3 41.1 51.2 51.2 51.9 50.7 60.3 39.5
90 66.2 66.2 66.4 65.6 70.3 50.3 63.7 63.7 63.7 63.7 68.4 51.2 60.3 60.3 60.3 60.3 64.9 50.3 56.4 56.4 56.3 56.3 60.8 49.1
1800
2000
2200
75 58.3 52.5 65.0 39.1 68.1 25.1 53.6 50.0 62.0 37.6 66.6 23.8 48.6 47.7 57.2 35.4 64.2 22.3 43.8 43.8 51.2 32.7 60.6 20.5
80
85 64.9 64.9 66.4 59.2 69.9 43.1 62.1 62.1 63.4 59.1 67.8 43.0 58.4 58.4 59.2 57.5 64.9 43.9 54.0 54.0 54.0 54.0 61.2 42.0
90 67.7 67.7 67.7 67.7 70.8 51.7 65.7 65.7 65.7 65.7 68.6 52.2 62.8 62.8 62.8 62.8 65.9 52.9 59.0 59.0 59.0 59.0 61.9 52.3
61.1 61.1 65.6 49.2 69.0 34.6 57.3 57.3 62.4 48.4 67.5 34.8 53.2 53.2 57.8 46.2 64.7 33.2 48.7 48.7 52.0 43.6 60.9 31.4
75 59.9 55.8 65.8 40.7 68.4 25.5 55.2 53.4 62.9 39.5 67.0 24.2 50.0 50.0 58.3 37.3 64.6 22.7 45.6 45.6 52.4 34.7 61.2 21.0
80 63.1 63.1 66.3 51.0 69.3 35.2 59.7 59.7 63.5 51.0 67.9 35.1 55.5 55.5 59.0 49.2 65.4 34.5 50.8 50.8 53.4 46.6 61.6 32.9
85 66.4 66.4 67.2 61.6 70.2 43.9 64.0 64.0 64.6 62.4 68.8 44.9 60.6 60.6 60.6 60.6 66.0 45.1 56.4 56.4 56.4 56.4 62.0 44.2
90 68.7 68.7 68.7 68.7 71.2 52.8 67.1 67.1 67.1 67.1 69.7 54.9 64.5 64.5 64.5 64.5 66.9 55.8 61.0 61.0 61.0 61.0 62.9 55.3
75
80 64.5 64.5 67.0 53.1 69.6 35.6 61.6 61.6 64.2 53.3 68.2 35.7 57.5 57.5 60.1 52.1 65.8 35.5 52.8 52.8 54.7 49.6 62.1 34.3
85 67.3 67.3 68.1 64.0 70.5 44.7 65.4 65.4 65.6 65.2 69.1 46.0 62.4 62.4 62.3 62.3 66.6 46.8 58.4 58.4 58.4 58.4 62.6 46.2
90 69.4 69.4 69.5 69.5 71.5 53.9 68.1 68.1 68.1 68.1 70.1 56.3 65.7 65.7 65.7 65.7 67.6 58.0 62.5 62.5 62.5 62.5 63.7 57.9
61.2 59.0 66.2 41.7 68.6 25.9 56.3 56.3 63.6 41.3 67.3 24.6 51.9 51.9 59.2 39.0 65.0 23.1 47.2 47.2 53.4 36.6 61.7 21.4
2400
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
RT-PRC005-EN
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(5Ton)
High Efficiency
Table PD-14 — Gross Cooling Capacities (MBH) 5Ton THC060A3, A4, AW – Dehumidification Option
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
73 61
CFM
Bulb
61
67
73
61
67
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 50.7 36.2 57.0 29.4 63.7 22.6 48.1 34.6 54.2 27.9 60.7 21.0 45.5 32.9 51.3 26.2 57.5 19.4 42.7 31.2 48.2 24.5 54.1 17.7
80 50.8 41.8 57.1 35.1 63.8 28.2 48.3 40.2 54.4 33.5 60.8 26.6 45.6 38.6 51.5 31.9 57.6 25.0 42.9 36.8 48.4 30.1 54.2 23.3
1000
1300
1600
85
51.0 47.5 57.2 40.7 64.0 33.8 48.6 45.9 54.5 39.1 61.0 32.2 46.0 44.2 51.6 37.4 57.8 30.6 43.3 42.5 48.5 35.7 54.4 28.8
90 52.2 52.2 57.4 46.3 64.1 39.4 50.1 50.1 54.6 44.7 61.1 37.8 47.8 47.8 51.7 43.0 57.9 36.1 45.5 45.5 48.7 41.3 54.5 34.4
75 54.3 41.5 60.7 32.7 67.6 23.8 51.5 39.9 57.7 31.0 64.3 22.1 48.6 38.1 54.5 29.3 60.8 20.4 45.5 36.4 51.1 27.5 57.0 18.7
80 54.6 48.8 60.9 40.0 67.8 31.0 51.9 47.1 57.9 38.3 64.5 29.3 49.0 45.4 54.7 36.6 60.9 27.6 46.0 43.6 51.3 34.8 57.2 25.9
85 55.6 55.6 61.1 47.2 67.9 38.2 53.2 53.2 58.1 45.5 64.6 36.5 50.7 50.7 54.9 43.7 61.1 34.8 48.1 48.1 51.5 41.9 57.4 33.0
90 58.8 58.8 61.5 54.4 68.1 45.3 56.3 56.3 58.5 52.7 64.8 43.6 53.7 53.7 55.3 50.9 61.3 41.9 51.0 51.0 52.0 49.1 57.5 40.1
75 56.8 46.5 63.2 35.6 70.2 24.7 53.9 44.9 60.0 33.9 66.6 23.0 50.8 43.1 56.6 32.2 62.9 21.3 47.5 41.3 53.0 30.4 58.9 19.5
80
57.6 55.5 63.4 44.5 70.3 33.5 54.7 53.8 60.2 42.7 66.8 31.8 51.6 51.6 56.8 41.0 63.0 30.1 48.8 48.8 53.2 39.1 59.1 28.3
85 60.3 60.3 63.8 53.2 70.5 42.2 57.7 57.7 60.6 51.5 67.0 40.5 54.9 54.9 57.3 49.7 63.2 38.8 52.0 52.0 53.7 47.9 59.3 36.9
90 63.8 63.8 64.7 62.1 70.8 50.9 61.1 61.1 61.6 60.4 67.3 49.2 58.2 58.2 58.2 58.2 63.5 47.4 55.1 55.1 55.1 55.1 59.6 45.6
75 58.1 49.6 64.5 37.5 71.4 25.2 55.1 48.2 61.1 35.8 67.8 23.5 51.9 46.3 57.6 34.0 63.9 21.8 48.6 44.5 53.9 32.2 59.8 20.0
80 59.3 59.3 64.7 47.4 71.6 35.1 56.6 56.6 61.4 45.6 67.9 33.4 53.8 53.8 57.9 43.8 64.1 31.6 50.8 50.8 54.2 42.0 60.0 29.8
85 62.9 62.9 65.3 57.2 71.8 44.9 60.1 60.1 62.0 55.4 68.2 43.1 57.2 57.2 58.6 53.6 64.3 41.3 54.1 54.1 55.0 51.8 60.2 39.5
90 66.5 66.5 66.5 66.5 72.2 54.6 63.7 63.7 63.7 63.7 68.5 52.9 60.6 60.6 60.6 60.6 64.7 51.0 57.4 57.4 57.4 57.4 60.7 49.1
1800
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC=SensibleHeatCapacity
RT-PRC005-EN
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(6, 7½Ton)
High Efficiency
Table PD-15 — Gross Cooling Capacities (MBH) 6Ton Three Phase THC072A3, A4, AW
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 67.3 56.6 73.6 42.5 74.5 27.6 61.6 53.5 71.8 41.9 75.1 26.6 55.8 50.4 66.8 38.7 74.1 25.3 49.8 47.2 59.9 36.3 71.3 23.5
80 68.7 68.2 73.8 51.7 75.4 37.0 63.6 63.6 72.0 52.1 76.0 38.1 58.9 58.9 66.9 49.7 74.7 36.4 54.1 54.1 60.2 46.5 71.5 34.5
85 72.2 72.2 74.5 61.4 76.2 44.5 69.2 69.2 72.5 62.8 76.8 46.1 64.6 64.6 67.8 60.9 75.0 46.2 59.5 59.5 61.3 57.7 71.7 45.4
90 74.7 74.7 75.3 70.6 77.0 51.9 73.4 73.4 73.7 73.2 77.7 55.1 70.1 70.1 70.1 70.1 75.6 56.1 65.4 65.4 65.4 65.4 72.1 55.8
2160
2400
2640
75 69.0 60.1 74.0 43.3 74.5 27.9 63.5 57.2 72.7 43.1 75.2 27.0 57.5 54.0 68.4 40.9 74.5 25.7 51.8 51.0 61.5 37.6 72.0 24.0
80 70.7 70.7 74.3 52.9 75.4 37.2 66.8 66.8 73.0 54.6 76.2 37.8 61.9 61.9 68.7 53.0 75.1 37.4 56.7 56.7 61.9 49.8 72.4 36.1
85 73.8 73.8 75.0 63.0 76.2 44.9 71.9 71.9 73.8 66.0 77.1 47.0 67.9 67.9 69.7 65.4 75.5 47.5 62.7 62.7 63.6 62.4 72.6 47.7
90 75.6 75.6 75.9 72.4 77.0 52.5 75.2 75.2 75.1 75.1 78.0 56.3 72.8 72.8 72.7 72.7 76.4 58.2 68.8 68.8 68.8 68.8 73.2 59.0
75 70.3 63.2 74.2 43.9 74.6 28.3 65.2 60.8 73.2 44.5 75.4 27.4 59.2 57.7 69.6 42.9 74.7 26.2 53.2 53.2 62.9 39.8 72.5 24.6
80 72.3 72.3 74.5 53.9 75.4 37.4 69.5 69.5 73.8 56.7 76.3 38.2 64.6 64.6 70.0 56.1 75.6 38.5 59.2 59.2 63.5 53.0 73.0 37.7
85 74.7 74.7 75.3 64.3 76.2 45.2 73.7 73.7 74.7 68.7 77.3 47.6 70.5 70.5 71.3 69.3 76.1 48.9 65.6 65.6 65.6 65.6 73.4 49.7
90 76.1 76.1 76.2 73.6 76.9 53.0 76.2 76.2 76.2 76.2 78.1 57.2 74.5 74.5 74.5 74.5 76.9 59.9 71.2 71.2 71.2 71.2 74.1 61.7
75
71.3 65.8 74.3 44.4 74.6 28.7 66.8 64.4 73.7 45.6 75.5 27.8 60.5 60.5 70.6 44.8 74.9 26.6 55.1 55.1 64.1 41.8 72.9 25.0
80 73.3 73.3 74.7 54.8 75.4 37.6 71.4 71.4 74.4 58.5 76.4 38.5 67.0 67.0 71.0 58.9 75.9 39.1 61.4 61.4 64.9 56.2 73.3 38.6
85 75.1 75.1 75.5 65.3 76.2 45.6 74.8 74.8 75.4 70.8 77.4 48.2 72.4 72.4 72.4 72.4 76.4 49.9 68.2 68.2 68.1 68.1 74.0 51.5
90 76.3 76.3 76.3 74.5 76.9 53.5 76.9 76.9 76.9 76.9 78.2 58.0 75.7 75.7 75.7 75.7 77.2 61.3 72.9 72.9 72.9 72.9 74.8 64.1
2880
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC=SensibleHeatCapacity
Table PD-16 — Gross Cooling Capacities (MBH) 7½Ton Three Phase THC092A3, A4, AW
AmbientTemperature (F)
85
95
105
67
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 85.7 72.4 95.8 56.8 99.9 37.1 79.3 69.3 92.0 53.7 98.8 35.8 72.8 66.0 85.9 50.8 96.1 34.2 66.1 62.6 78.5 49.1 91.8 32.2
80
87.5 87.0 96.2 68.5 101.1 50.4 81.8 81.8 92.4 67.4 99.6 50.2 76.6 76.6 86.2 64.6 96.7 48.0 71.1 71.1 79.0 61.4 92.0 45.8
2700
3000
3300
85 92.8 92.8 97.0 81.6 102.3 61.3 88.5 88.5 93.1 81.1 100.3 61.3 83.4 83.4 87.1 78.6 97.0 60.9 77.9 77.9 80.3 75.4 92.3 59.4
90
75
80 90.5 90.5 97.4 71.2 101.6 51.1 85.6 85.6 94.0 71.0 100.4 50.9 80.2 80.2 88.2 68.7 97.3 49.8 74.5 74.5 81.0 65.5 93.2 47.9
85 95.6 95.6 98.4 85.1 102.9 62.5 92.2 92.2 95.0 85.8 101.3 63.3 87.3 87.3 89.5 84.1 98.1 63.3 81.8 81.8 82.9 81.2 93.6 62.5
90 99.4 99.4 99.9 98.1 104.1 74.1 97.2 97.2 97.2 97.2 102.1 75.5 93.6 93.6 93.5 93.5 99.1 77.0 88.8 88.8 88.7 88.7 94.4 76.9
75 89.8 81.3 97.5 59.0 100.7 38.1 83.6 78.2 94.6 58.3 99.8 37.1 77.0 75.0 89.2 55.9 97.5 35.4 70.0 70.0 82.1 52.8 93.6 33.4
80 93.2 93.2 98.3 73.5 102.0 51.7 88.9 88.9 95.2 74.2 101.0 52.0 83.4 83.4 89.8 72.6 97.9 50.6 77.6 77.6 82.8 69.5 94.1 49.9
97.2 97.2 98.3 94.2 103.5 72.4 94.3 94.3 94.3 94.3 101.1 73.1 90.0 90.0 90.0 90.0 97.8 73.7 84.9 84.9 84.9 84.9 92.9 72.7
87.9 77.0 96.6 57.3 100.4 37.6 81.5 73.7 93.5 56.1 99.4 36.4 74.9 70.5 87.8 53.4 96.9 34.8 67.4 67.4 80.5 50.2 92.8 32.8
85
90 100.9 100.9 100.9 100.9 104.6 75.6 99.2 99.2 99.2 99.2 102.8 77.7 96.1 96.1 96.1 96.1 100.1 80.0 91.8 91.8 91.8 91.8 95.7 80.7
75 91.5 85.3 98.2 60.6 101.0 38.6 85.5 82.6 95.4 60.2 100.2 37.5 78.5 78.5 90.5 58.3 98.0 35.9 72.4 72.4 83.4 55.2 94.3 34.0
97.6 97.6 99.4 88.0 103.3 67.9 94.9 94.9 96.5 90.0 101.9 64.8 90.5 90.5 91.7 89.4 99.0 67.3 85.2 85.2 85.1 85.1 94.7 65.2
80 95.2 95.2 99.0 75.4 102.3 56.8 91.5 91.5 96.3 77.2 101.5 52.7 86.3 86.3 91.3 76.3 98.4 51.4 80.4 80.4 84.4 73.4 94.7 51.4
85 99.1 99.1 100.2 90.6 103.6 69.8 96.9 96.9 97.8 93.6 102.4 66.1 93.1 93.1 93.1 93.1 99.7 69.8 88.0 88.0 87.9 87.9 95.6 67.8
90 101.9 101.9 101.9 101.9 105.0 76.9 100.7 100.7 100.7 100.7 103.4 79.6 98.0 98.0 97.9 97.9 100.8 82.5 94.0 94.0 94.0 94.0 96.7 84.1
3600
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity
RT-PRC005-EN
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(8½, 10 Ton)
High Efficiency
Table PD-17 — Gross Cooling Capacities (MBH) 8½Ton Three Phase THC102A3, A4, AW
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 94.0 81.8 105.7 62.8 110.8 40.9 86.3 77.8 100.7 59.7 109.7 39.3 79.0 74.2 92.4 56.0 105.5 37.1 71.8 70.5 84.0 53.1 99.6 34.6
80 96.9 96.9 106.2 77.6 112.0 56.0 90.6 90.6 101.1 75.9 110.1 55.4 84.5 84.5 92.9 72.2 106.1 53.2 78.3 78.3 84.7 68.5 99.8 50.6
85 103.5 103.5 107.2 92.9 113.2 68.7 98.6 98.6 102.2 92.1 111.6 70.3 92.1 92.1 94.5 88.8 106.4 68.8 85.8 85.8 86.7 85.2 100.0 66.5
90 108.4 108.4 109.0 107.7 114.4 81.6 105.0 105.0 105.0 105.0 112.6 84.9 99.9 99.9 99.9 99.9 107.3 83.9 93.5 93.5 93.5 93.5 100.8 82.6
75 96.6 87.2 107.1 64.7 111.4 41.5 88.7 83.3 102.4 62.6 110.7 40.1 81.4 79.6 94.4 59.1 106.6 37.9 74.2 74.2 85.9 55.4 101.1 35.5
80 100.9 100.9 107.7 81.0 112.7 56.9 94.9 94.9 103.0 80.4 111.7 57.5 88.3 88.3 95.2 77.1 107.3 55.7 81.8 81.8 86.8 73.4 101.4 53.1
85 106.6 106.6 108.9 97.4 114.0 70.2 102.6 102.6 104.4 97.8 112.8 72.9 96.5 96.5 97.6 95.6 108.0 72.4 89.9 89.9 89.8 89.8 101.8 70.8
90 110.8 110.8 110.8 110.8 115.3 83.8 108.1 108.1 108.1 108.1 114.0 88.5 103.8 103.8 103.8 103.8 108.9 88.3 97.8 97.8 97.8 97.8 102.8 87.9
75 98.9 92.5 107.4 65.9 112.0 42.2 91.2 88.7 103.7 65.4 111.1 40.7 83.5 83.5 96.3 62.2 107.5 38.7 76.9 76.9 87.5 58.4 102.2 36.2
80 103.7 103.7 108.8 84.0 113.3 57.7 98.7 98.7 104.5 84.5 112.4 58.7 91.7 91.7 97.3 81.9 108.3 57.6 85.0 85.0 88.8 78.2 102.6 55.5
85 108.8 108.8 110.1 100.9 114.6 76.9 105.4 105.4 106.4 103.0 113.7 75.1 100.2 100.2 100.2 100.2 109.3 75.7 93.4 93.4 93.4 93.4 103.1 74.4
90 112.3 112.3 112.1 112.1 115.9 85.7 110.4 110.4 110.4 110.4 114.9 91.4 106.5 106.5 106.5 106.5 110.2 92.3 101.3 101.3 101.3 101.3 104.4 92.7
3060
3400
3740
75 100.9 97.3 108.1 67.4 112.5 42.9 93.1 93.1 104.7 67.9 111.5 41.4 86.2 86.2 97.8 65.2 108.2 39.4 79.4 79.4 88.8 61.3 103.0 36.9
80 105.9 105.9 109.5 86.2 113.8 58.4 101.6 101.6 105.8 88.2 112.8 59.6 94.9 94.9 99.1 86.5 109.2 59.6 87.9 87.9 90.6 82.8 103.5 57.8
85 110.2 110.2 110.9 103.4 115.1 79.5 107.6 107.6 107.6 107.6 114.1 76.6 103.0 103.0 103.0 103.0 109.9 77.6 96.6 96.6 96.6 96.6 104.2 77.7
90 112.9 112.9 112.9 112.9 116.5 87.5 112.2 112.2 112.2 112.2 115.4 93.4 108.6 108.6 108.6 108.6 111.3 95.9 103.9 103.9 103.9 103.9 105.8 97.0
4080
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC=SensibleHeatCapacity
Table PD-18 — Gross Cooling Capacities (MBH) 10 Ton Three Phase THC120A3, A4, AW
AmbientTemperature (F)
85
95
105
67
115
67
Enter.
Dry
EnteringWet Bulb (F)
73
CFM
Bulb
61
67
73
61
67
61
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 107.0 94.4 117.4 75.0 123.4 46.0 98.7 90.1 114.7 68.8 121.9 44.4 88.5 88.5 107.2 65.3 118.6 42.2 82.3 78.8 97.8 61.1 113.6 39.6
80 110.9 108.6 119.9 88.2 125.0 62.5 104.5 104.1 115.2 87.5 123.4 62.3 97.7 97.7 107.8 84.3 119.4 60.8 90.6 90.6 98.5 80.1 114.3 58.3
85 117.6 117.6 120.9 105.0 126.6 76.7 113.1 113.1 116.5 105.8 124.9 78.1 106.9 106.9 107.0 107.0 120.9 78.1 99.9 99.9 100.0 100.0 114.8 76.5
90 122.5 122.5 122.4 122.4 128.2 91.1 119.6 119.6 119.6 117.1 126.4 94.1 115.0 115.0 114.7 114.6 121.6 94.3 109.0 109.0 109.0 109.0 115.8 94.3
3600
4000
4400
75 109.8 100.5 119.4 71.9 122.5 46.5 99.7 99.7 116.1 71.5 121.7 45.0 92.5 92.5 110.1 69.1 119.4 43.0 85.6 83.4 100.9 65.0 114.6 40.5
80 114.6 114.1 120.8 90.1 124.1 68.3 109.3 109.3 117.0 91.2 123.4 62.7 102.3 102.3 110.8 89.9 120.6 62.5 94.8 94.8 101.9 86.0 115.5 61.1
85 120.5 120.5 122.3 107.9 125.9 76.4 117.0 117.0 118.6 110.2 125.0 78.8 111.6 111.6 111.8 111.8 122.1 80.4 104.7 104.7 105.8 102.6 116.3 79.7
90 125.2 125.2 124.2 124.2 127.6 90.9 122.4 122.4 121.7 120.9 126.6 95.1 118.5 118.5 118.3 118.3 123.6 98.4 113.1 113.1 113.3 113.3 117.7 98.6
75 112.3 106.1 121.2 74.8 124.6 47.6 103.6 103.6 117.1 75.5 123.0 46.0 96.7 93.9 111.2 72.2 120.0 43.7 88.6 88.0 102.0 68.2 115.3 41.2
80 117.6 117.6 122.5 94.7 126.3 64.2 113.0 113.0 118.4 95.8 124.7 64.4 106.3 106.3 112.2 94.9 121.5 64.3 98.8 98.8 103.5 91.1 116.1 62.8
85 122.4 122.4 124.3 113.8 128.0 79.6 119.6 119.6 119.6 119.6 126.4 81.8 115.1 115.1 115.5 111.7 122.7 83.0 109.1 109.1 108.8 107.4 117.2 83.2
90 126.0 126.0 127.1 125.0 129.6 95.2 124.3 124.3 124.2 124.2 128.0 99.4 120.9 120.9 120.9 120.9 123.9 101.2 116.1 116.1 116.1 116.1 118.8 103.3
75 113.4 113.4 121.8 76.2 125.0 48.4 107.6 104.0 118.5 77.0 123.5 46.9 99.6 98.2 112.7 75.4 120.5 44.8 91.6 91.6 103.7 71.6 115.9 41.9
80 119.5 119.5 123.2 97.0 126.7 64.8 115.8 115.8 119.8 99.6 125.2 65.3 109.8 109.8 113.9 99.4 122.1 65.5 102.3 102.3 105.5 96.3 117.2 66.8
85 124.3 124.3 125.2 116.6 128.4 80.7 121.5 121.5 121.5 121.5 126.9 83.3 117.5 117.5 117.6 115.4 123.7 85.6 111.8 111.8 111.8 111.8 118.5 86.4
90 127.5 127.5 128.0 126.7 130.1 96.9 126.0 126.0 125.5 125.5 128.6 101.5 122.6 122.6 123.0 123.0 125.5 105.5 118.2 118.2 118.2 118.2 120.3 107.5
4800
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC=SensibleHeatCapacity
RT-PRC005-EN
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(10 Ton)
High Efficiency
Table PD-19— Gross Cooling Capacities (MBH) 10Ton THC120A3, A4, AW – Dehumidification Option
AmbientTemperature (F)
85
95
105
115
67
Enter.
Dry
EnteringWet Bulb (F)
73 61
CFM
Bulb
61
67
73
61
67
67
73
61
73
Airflow
(F) MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC
75 94.2 68.9 105.8 56.2 118.4 42.6 89.7 66.2 101.0 53.6 113.2 40.0 84.8 63.4 95.8 50.9 107.6 37.3 79.7 60.4 90.2 48.1 101.5 34.6
80 94.4 79.8 106.0 66.8 118.6 53.6 89.9 77.1 101.2 64.1 113.4 51.0 85.0 74.2 96.0 61.4 107.8 48.3 79.9 71.2 90.4 58.4 101.7 45.4
85 93.0 93.0 106.3 77.6 118.8 64.3 90.4 86.3 101.4 74.9 113.6 61.7 86.1 82.8 96.2 72.1 108.0 59.0 81.6 79.1 90.7 69.2 101.9 56.1
90 98.0 97.2 106.4 88.3 119.0 75.0 94.4 94.4 101.6 85.6 113.8 72.4 90.4 90.4 96.4 82.8 108.2 69.6 86.1 86.1 90.9 79.8 102.1 66.7
2000
2600
3200
75 100.5 78.8 112.6 62.6 125.6 44.8 95.6 76.0 107.3 59.9 119.9 42.2 90.4 73.0 101.6 57.1 113.8 39.5 84.8 70.0 95.6 54.1 107.2 36.6
80 101.1 92.6 112.9 75.8 125.8 58.8 96.4 89.9 107.6 73.1 120.1 56.1 89.7 89.7 101.9 70.2 114.0 53.3 86.0 81.9 95.8 67.1 107.4 50.4
85 104.0 102.0 113.2 89.6 126.1 72.5 99.7 98.7 107.9 86.8 120.4 69.8 95.4 95.4 102.3 83.9 114.2 67.0 90.6 90.6 96.2 80.9 107.6 64.0
90 109.9 109.9 113.9 103.3 126.4 86.1 105.6 105.6 108.7 100.5 120.7 83.4 101.1 101.1 101.1 101.1 114.5 80.6 96.2 96.2 97.5 92.3 107.9 77.6
75 104.9 87.8 117.1 67.4 130.2 46.6 99.8 85.0 111.5 65.7 124.2 44.0 94.3 82.0 110.8 64.8 117.7 41.2 88.4 78.9 99.0 59.8 110.7 38.2
80 106.6 102.0 117.4 84.1 130.5 63.4 102.0 98.4 111.8 81.3 124.5 60.6 97.0 94.6 105.8 78.4 118.0 57.8 91.6 90.5 99.4 75.3 111.0 54.8
85 112.2 112.2 118.1 100.7 130.8 79.9 107.8 107.8 112.6 98.0 124.7 77.2 103.0 103.0 106.7 95.0 118.2 74.3 97.7 97.7 100.4 91.9 111.2 71.3
90 118.6 118.6 118.8 118.8 131.1 96.5 114.2 114.2 115.0 110.5 125.1 93.7 109.2 109.2 109.6 106.5 118.7 90.8 103.8 103.8 103.9 102.2 111.7 87.8
75 107.3 93.6 119.4 70.7 132.5 47.7 102.1 90.8 113.6 67.9 126.3 45.0 96.5 87.8 107.2 64.9 119.4 42.1 90.4 84.7 100.6 61.8 112.1 39.1
80 110.3 107.5 119.7 89.4 132.8 66.3 105.6 104.0 114.0 86.6 126.6 63.5 100.4 100.3 107.6 83.5 119.6 60.5 95.1 95.1 101.1 80.4 112.4 57.5
85 116.7 116.7 120.8 107.9 133.2 84.7 112.2 112.2 115.2 105.1 126.9 82.0 107.1 107.1 108.9 102.1 119.9 79.0 101.4 101.4 101.4 101.4 112.7 75.9
90 123.5 123.5 124.2 120.7 133.7 103.1 118.8 118.8 119.0 116.9 127.5 100.3 113.6 113.6 113.2 112.8 120.6 97.3 107.7 107.7 107.7 107.7 113.4 94.2
3600
NOTES:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC=SensibleHeatCapacity
RT-PRC005-EN
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(3, 4, 5Ton)
Standard Efficiency
Table PD-20— Direct Drive Evaporator Fan Performance 3, 4 and 5 Ton TSC036A, TSC048A, TSC060A
External Static Pressure (Inches ofWater) & Motor Power (Bhp)1
Standard Motor
High Speed Low Speed
Oversized Motor
High Speed Low Speed
Unit
Tons
3
Model No. CFM
ESP
BHP
ESP
BHP
ESP
BHP
ESP
BHP
960
1020
1080
0.81
0.77
0.73
0.69
0.66
0.60
0.55
0.49
0.44
0.36
0.37
0.38
0.39
0.40
0.41
0.42
0.42
0.43
0.61
0.57
0.50
0.42
0.34
0.26
0.14
0.05
—
0.28
0.28
0.29
0.29
0.30
0.30
0.31
0.31
—
0.96
0.94
0.91
0.88
0.84
0.80
0.75
0.70
0.64
0.39
0.41
0.43
0.44
0.45
0.46
0.48
0.49
0.52
0.89
0.86
0.82
0.77
0.74
0.70
0.65
0.59
0.54
0.35
0.47
0.39
0.40
0.41
0.42
0.44
0.45
0.48
1140
TSC036A 1200
Horizontal 1260
1320
1380
1440
1280
1360
1440
0.93
0.87
0.80
0.73
0.66
0.57
0.47
0.37
0.27
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.81
0.75
0.68
0.60
0.51
0.38
0.23
0.13
—
0.47
0.47
0.48
0.48
0.49
0.49
0.50
0.50
—
1.20
1.15
1.10
1.05
1.00
0.95
0.90
0.83
0.75
0.67
0.68
0.70
0.73
0.75
0.78
0.82
0.83
0.85
0.99
0.94
0.88
0.81
0.74
0.65
0.50
0.35
0.25
0.56
0.58
0.60
0.63
0.64
0.66
0.68
0.70
0.73
1520
4
5
3
4
5
TSC048A 1600
Horizontal 1680
1760
1840
1920
1600
1700
1800
0.90
0.85
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.86
0.82
0.78
0.74
0.71
0.65
0.60
0.54
0.49
0.98
0.92
0.85
0.78
0.71
0.62
0.52
0.42
0.32
0.95
0.90
0.85
0.75
0.65
0.55
0.45
0.35
0.25
0.78
0.82
0.85
0.88
0.90
0.93
0.95
0.97
1.00
0.36
0.37
0.38
0.39
0.40
0.41
0.42
0.42
0.43
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.78
0.82
0.85
0.88
0.90
0.93
0.95
0.97
1.00
0.82
0.68
0.56
0.46
0.30
0.14
0.05
—
0.64
0.65
0.65
0.65
0.66
0.66
0.67
—
1.20
1.15
1.05
0.98
0.90
0.80
0.70
0.60
0.48
1.01
0.99
0.96
0.93
0.89
0.85
0.80
0.75
0.69
1.25
1.20
1.15
1.10
1.05
1.00
0.95
0.88
0.80
1.25
1.20
1.10
1.03
0.95
0.85
0.75
0.65
0.53
0.90
0.94
0.98
1.02
1.05
1.10
1.12
1.17
1.20
0.39
0.41
0.43
0.44
0.45
0.46
0.48
0.49
0.52
0.67
0.68
0.70
0.73
0.75
0.78
0.82
0.83
0.85
0.90
0.94
0.98
1.02
1.05
1.10
1.12
1.17
1.20
1.05
0.95
0.85
0.75
0.65
0.50
0.35
0.15
—
0.89
0.91
0.87
0.82
0.79
0.75
0.70
0.64
0.59
1.04
0.99
0.93
0.86
0.79
0.70
0.55
0.40
—
1.10
1.00
0.90
0.80
0.70
0.55
0.40
0.20
—
0.85
0.89
0.91
0.94
0.95
0.96
0.96
0.97
—
0.35
0.47
0.39
0.40
0.41
0.42
0.44
0.45
0.48
0.56
0.58
0.60
0.63
0.64
0.66
0.68
0.70
—
0.85
0.89
0.91
0.94
0.95
0.96
0.96
0.97
—
1900
TSC060A3 2000
Horizontal 2100
2200
2300
2400
960
1020
1080
—
—
0.61
0.62
0.55
0.47
0.39
0.31
0.19
0.10
—
0.86
0.80
0.73
0.65
0.56
0.43
0.28
0.18
—
0.87
0.73
0.61
0.51
0.35
0.19
0.10
—
0.28
0.28
0.29
0.29
0.30
0.30
0.31
0.31
—
0.47
0.47
0.48
0.48
0.49
0.49
0.50
0.50
—
0.64
0.65
0.65
0.65
0.66
0.66
0.67
—
1140
TSC036A 1200
Downflow 1260
1320
1380
1440
1280
1360
1440
1520
TSC048A 1600
Downflow 1680
1760
1840
1920
1600
1700
1800
1900
TSC060A3 2000
Downflow 2100
2200
2300
2400
—
—
Fan motor heat (MBH) = 3.72 x Fan Bhp + .24.
Trane’s factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate
reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data
will not result in nuisance tripping or premature motor failure. Our product’s warranty will not be affected.
NOTES:
1. Data includes pressure drop due to wet coil and filters.
2. 5 ton oversized motor performance is with 12 x 11 FC blower wheel.
3. YSC060AK uses a 1.0 hp direct drive motor and 12x11 FC centrifugal blower wheel. Refer to oversized motor column for the standard
motor performance data.
RT-PRC005-EN
26
Download from Www.Somanuals.com. All Manuals Search And Download.
(3Ton)
Standard Efficiency
Performance
Data
Table PD-21 — Belt Drive Evaporator Fan Performance — 3 Ton —TSC036A3,A4,AW — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor
& Field Supplied
Low Static Drive (1)
1-HP Standard Motor & Drive
960
—
—
—
—
528
557
588
622
657
0.12
0.15
0.19
0.23
0.28
599
625
652
681
713
0.16
0.19
0.23
0.27
0.33
658
685
712
738
765
0.20
0.24
0.28
0.32
0.37
713
738
764
790
817
0.24
0.28
0.33
0.38
0.43
763
786
811
838
865
0.29
0.33
0.38
0.44
0.50
810
832
856
882
909
0.33
0.38
0.43
0.49
0.56
855
876
898
923
949
0.38
0.43
0.48
0.55
0.62
898 0.43
917 0.48
939 0.54
962 0.60 1000 0.66
987 0.68 1024 0.74
939 0.49
957 0.54
978 0.59
1080
1200
1320
1440
—
—
552
588
0.18
0.23
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1. FieldSuppliedFanSheaveAK69required. FieldSuppliedBeltmaybenecessary.
2. FieldSuppliedFanSheaveAK41required.FieldSuppliedBeltmaybenecessary.
Table PD-21 — Continued
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM BHP RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
BHP
BHP
BHP
1-HPStandardMotor&Drive
960
978
995
0.54
0.59
1016
1033
1051
1072
1094
0.60
0.65
0.71
0.78
0.86
1052
0.66
0.71
0.77
0.85
0.93
1086
1103
1120
1138
1160
0.72
0.78
0.84
0.91
1.00
1120
1136
1154
1171
1192
0.78
0.84
0.91
0.98
1.07
1080
1200
1320
1440
1069
1086
1106
1128
1015 0.65
1036 0.72
1060 0.80
1-HPStandardMotor&
Field Supplied High Static Drive (2)
Table PD-22 — Belt Drive Evaporator Fan Performance — 3 Ton — TSC036A3,A4,AW — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
960
—
—
588
622
654
687
723
0.15
0.18
0.23
0.28
0.33
661
694
727
760
793
0.19
0.24
0.28
0.34
0.40
725
756
787
821
855
0.24
0.29
0.34
0.40
0.47
782
813
843
875
908
0.29
0.34
0.40
0.46
0.53
832
864
895
925
956
0.35
0.40
0.46
0.53
0.60
878
910
942
973
0.40
0.46
0.52
0.59
919
954
986
1017
0.46
0.52
958 0.51
993 0.59 1031 0.65
996 0.56
1080
1200
1320
1440
531
570
610
651
0.13
0.17
0.22
0.27
0.59 1026 0.66 1064 0.73
0.66 1058 0.73 1095 0.81
1003 0.67 1047 0.75 1088 0.82
1127 0.89
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories.
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1-HPStandardMotor&
Field Supplied High Static Drive
(2)
1. FieldSuppliedFanSheaveAK69required. FieldSuppliedBeltmaybenecessary.
2. FieldSuppliedFanSheaveAK41required.FieldSuppliedBeltmaybenecessary.
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
Table PD-22 — Continued
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM BHP RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
1-HPStandardMotor&Drive
BHP
BHP
BHP
960
1032 0.62
1065 0.70
1099 0.80
1066
1099
1133
1167
1199
0.67
0.76
0.86
0.96
1.05
1101
0.73
0.82
0.93
1.04
1.14
1133
1164
1197
1230
1263
0.79
0.89
0.99
1.11
1.22
1166
1194
1227
1261
1294
0.86
0.95
1.06
1.19
1.30
1080
1200
1320
1440
1132
1166
1200
1232
1132
1164
0.88
0.97
1-HPStandardMotor&
Field Supplied High Static Drive (2)
RT-PRC005-EN
27
Download from Www.Somanuals.com. All Manuals Search And Download.
(4Ton)
Standard Efficiency
Performance
Data
Table PD-23 — Belt Drive Evaporator Fan Performance — 4 Ton — TSC048A3,A4,AW — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
1280
1440
1600
1760
1920
—
—
616
663
711
758
807
0.22
0.29
0.37
0.46
0.57
677
719
764
811
859
0.26
0.33
0.42
0.52
0.64
734
772
813
856
903
0.31
0.38
0.47
0.58
0.71
787
823
860
901
945
0.37
0.44
0.53
0.64
0.77
834
871
906
944
985
0.42
0.51
0.59
0.70
0.83
878
914
951
986
0.48
0.57
0.66
919
954
992
0.53
0.63
0.74
959 0.59
993 0.69 1029 0.75
1029 0.80 1065 0.87
997 0.64
596
647
701
755
0.23
0.31
0.41
0.52
0.77 1027 0.85 1066 0.93
1101 1.05
1102 1.00
1137 1.14
1024 0.89 1063 0.97
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1. FieldSuppliedFanSheaveAK61required. FieldSuppliedBeltmaybenecessary.
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
Table PD-23 — Continued
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
BHP
BHP
BHP
BHP
1-HPStandardMotor&Drive
1280
1440
1600
1760
1920
1033 0.70
1066 0.81
1099 0.93
1069 0.77
1099 0.87
1103
0.83
0.94
1.07
1.22
1.39
1136
1165
1196
1229
—
0.89
1.01
1.14
1.29
—
1170
1196
1228
—
0.96
1.08
1.21
—
1133
1166
1200
1236
1132
1168
1205
1.00
1.15
1.31
1136
1172
1.08
1.23
—
—
Table PD-24 — Belt Drive Evaporator Fan Performance — 4 Ton — TSC048A3,A4,AW — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
1280
1440
1600
1760
1920
604
660
717
774
833
0.20
0.28
0.36
0.47
0.59
683
731
783
837
892
0.26
0.34
0.43
0.54
0.67
756
800
846
894
946
0.32
0.41
0.51
0.62
0.76
816
862
907
952
998
0.39
0.48
0.58
0.70
0.85
869
914
961
1006 0.79
1050 0.94
0.45
0.54
0.66
920
963
0.51
0.61
1008 0.73
1054 0.87
967
0.57
1011
0.64 1052 0.71 1090 0.79
1009 0.68 1053 0.76
1053 0.81 1095 0.89
1094 0.83
1135 0.97
1178 1.12
1224 1.30
1133 0.91
1174 1.05
1216 1.21
1259 1.39
1098 0.95
1144 1.12
1139
1185
1.04
1.21
1100
1.03
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories.
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1-HPStandardMotor&
Field Supplied High Static Drive
1. FieldSuppliedFanSheaveAK61required. FieldSuppliedBeltmaybenecessary.
2. FieldSuppliedFanSheaveAK41required.FieldSuppliedBeltmaybenecessary.
Trane’s factory supplied motors, in commercial equipment, are definite purpose motors,
specifically designed and tested to operate reliably and continuously at all cataloged
conditions. Using the full horsepower range of our fan motors as shown in our tabular
data will not result in nuisance tripping or premature motor failure. Our product’s
warranty will not be affected.
Table PD-24 — Continued
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM BHP RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
1-HPStandardMotor&Drive
0.86
0.98
1.13
1.30
1.48
BHP
BHP
BHP
1280
1440
1600
1760
1920
1125
1169
1211
1253
1295
1160
1204
1247
1289
—
0.94
1.07
1.21
1.39
—
1192
1.01
1.15
1.30
1.47
—
1223
1269
1312
—
1.08
1.23
1.39
—
1254
1300
1343
—
1.15
1.32
1.48
—
1237
1280
1322
—
—
—
—
—
1-HPStandardMotor&
Field Supplied High Static Drive
RT-PRC005-EN
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(5Ton)
Standard Efficiency
Table PD-25— Belt Drive Evaporator Fan Performance — 5 Ton — TSC060A3,A4,AW — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
1600
1800
2000
2200
2400
674
743
813
886
959
0.33
0.46
0.61
0.80
1.03
735
801
0.39
0.52
0.68
0.87
1.10
786
849
914
0.45
0.59
0.76
0.96
1.19
835
894
956
0.50
0.65
0.83
1.03
1.28
883
937
995
1057
1121
0.56
0.70
0.89
1.11
928
979
1035 0.96
1093
1154
0.63
0.77
972
0.70
1011
0.77 1048 0.84 1084 0.90
1021 0.85 1060 0.93 1098 1.01
1134 1.09
1183 1.28
1233 1.50
866
933
1000
1073
1129
1188
1.02
1.25
1.53
1111
1.10
1.33
1147 1.19
1198 1.40
980
1045
1019
1085
1.18
1.45
1164
1.36
1221 1.60
—
—
—
—
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1. FieldSuppliedFanSheaveAK56required. FieldSuppliedBeltmaybenecessary.
Table PD-25 — Continued
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM BHP RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
BHP
BHP
BHP
1-HPStandardMotor&Drive
1600
1800
2000
2200
2400
1117
1167
1216
—
0.97
1.16
1.37
—
1150
1199
1249
—
1.04
1.24
1.47
—
1183
1.11
1.31
—
1215
1259
—
1.18
1.39
—
1244
1289
—
1.25
1.47
—
1230
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Table PD-26 — Belt Drive Evaporator Fan Performance — 5 Ton — TSC060A3,A4,AW — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
1600
1800
2000
2200
2400
746
824
902
981
1061
0.39
0.54
0.72
0.93
1.19
812
883
957
1032
1109
0.47
0.62
0.80
1.03
1.29
876
940
1008 0.90
1080
1153
0.54
0.70
934
996
1059 0.99
1126
1196
0.62
0.79
985
0.70
1032 0.77
1094 0.96
1074 0.85
1137 1.05
1200 1.28
1117
1176
1239 1.38
0.93
1.14
1157 1.01
1214 1.22
1276 1.47
1196 1.09
1252 1.31
1311 1.50
1048 0.88
1110
1173
—
1.09
1.34
—
1157
1219
—
1.19
1.44
—
1.13
1.40
1.23
1.50
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories.
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1. FieldSuppliedFanSheaveAK56required. FieldSuppliedBeltmaybenecessary.
Table PD-26 — Continued
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM BHP RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
BHP
BHP
BHP
1-HPStandardMotor&Drive
1600
1800
2000
2200
2400
1232
1289
—
—
—
1.18
1.41
—
1267
1323
—
1.26
1.50
—
1299
1.35
—
1332
—
1.45
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
RT-PRC005-EN
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(6 Ton)
Standard Efficiency
Table PD-27 — Belt Drive Evaporator Fan Performance — 6-Ton — TSC072A3,A4,AW — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
1920
2160
2400
2640
2880
—
—
—
—
—
—
—
573
602
635
670
706
0.34
0.42
0.52
0.64
0.78
630
656
682
715
749
0.41
0.50
0.60
0.72
0.86
680
706
732
758
789
0.48
0.58
0.69
0.81
0.96
726
751
777
802
830
0.55
0.65
0.77
0.91
1.06
769
792
818
845
870
0.62
0.73
0.86
1.01
1.16
811
832
856
883
909
0.70
0.81
0.95
1.10
1.27
851 0.78
871 0.90
893 1.04
919 1.20
945 1.37
889 0.87
908 0.99
930 1.13
953 1.29
979 1.48
548
584
621
660
0.35
0.45
0.56
0.69
—
569
612
0.47
0.60
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
1-HPFanMotorHeat(MBH)=2.829xFanBHP+.4024.
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
2-HPFanMotorHeat(MBH)=3.000xFanBHP+.5000
1. FieldSuppliedFanSheaveAK84andBeltAX34required.
Table PD-27 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
1 HP Standard Motor & Drive
1.20
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
BHP
RPM
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
1HP Standard Motor & High Static Drive Kit
(or2HPOversizedMotor&Drive)
1920
2160
2400
2640
2880
925
944
964
986
1011
0.95
1.08
1.22
1.39
1.58
960
978
998
1019
1043
1.03
1.17
1.32
1.49
1.69
994
1010
1030
1051
1073
1.11
1.26
1.42
1.60
1.79
1026
1043
1063
1082
1103
1.19
1.36
1.53
1.71
1.90
1057
1073
1092
1112
1133
1.27
1.44
1.63
1.81
2.02
1087
1104
1123
1141
1161
1.36
1.54
1.73
1.92
2.13
1116
1133
1151
1169
1190
1.44
1.63
1.83
2.03
2.26
1144
1162
1179
1198
—
1.52
1.72
1.93
1173 1.61 1200 1.70
1189 1.81 1216 1.91
1206 2.03 1233 2.13
2.15 1225 2.26
—
—
—
—
—
—
—
2 HP Oversized Motor & Drive
Table PD-28 — Belt Drive Evaporator Fan Performance — 6-Ton — TSC072A3,A4,AW — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HPStandardMotor
& Field Supplied
Low Static Drive (1)
1-HP Standard Motor & Drive
1920
2160
2400
2640
2880
—
—
565
609
660
710
762
0.31
0.41
0.54
0.68
0.86
627
663
701
745
795
0.39
0.48
0.60
0.76
0.94
679
716
751
788
828
0.45
0.57
0.69
0.83
1.02
726
762
798
833
869
0.52
0.64
0.78
0.93
1.11
771
804
839
875
911
0.60
0.72
0.87
1.04
1.21
814
843
877
914
950
0.69
0.80
0.95
1.13
1.33
857
883
914
949
986
0.77
0.90
1.04
1.22
1.44
899 0.85
922 0.99
950 1.14
984 1.31
1019 1.53
2-HP Oversized
Motor & Drive
939 0.93
960 1.08
984 1.24
1016 1.42
1051 1.63
566
619
672
726
0.35
0.47
0.61
0.77
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrange
of our fan motors as shown in our tabular data will not result in nuisance
tripping or premature motor failure. Our product’s warranty will not be
affected.
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredrop
duetootheroptions/accessories.
1HPStandard Motor&HighStatic Drive
Kit(or 2 HP Oversized Motor & Drive)
1-HPFanMotorHeat(MBH)=2.829xFanBHP+.4024.
2-HPFanMotorHeat(MBH)=3.000xFanBHP+.5000
1. FieldSuppliedFanSheaveAK84andBeltAX34required.
Table PD-28 — Continued
External Static Pressure (Inches ofWater)
1.10
1.20
1.30
1.40
1.50
1.60
1.70
1.80
1.90
2.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard
Motor& Drive
1-HP Standard Motor & High Static Drive Kit
(or 2 HP oversized Motor& Drive)
1920
2160
2400
2640
2880
978
996
1.02
1.17
1.35
1.53
1.74
1015
1034
1055
1081
1112
1.11
1.27
1.45
1.65
1.86
1051
1069
1089
1113
1141
1.20
1.36
1.55
1.76
1.97
1086
1103
1122
1144
1170
1.30
1.46
1.66
1.87
2.10
1118
1136
1154
1176
1199
1.39
1.56
1.76
1.98
2.22
1150
1169
1186
1207 2.10
—
1.49
1.67
1.86
1180
1199
1216
1237 2.21
—
1.58
1.77
1.97
1209 1.68
1229 1.88
1246 2.08 1276 2.20
1236 1.77
1258 1.98
1263 1.86
—
—
—
—
—
—
—
—
1020
1049
1081
—
—
—
—
—
—
—
—
—
—
2-HP Oversized Motor & Drive
RT-PRC005-EN
30
Download from Www.Somanuals.com. All Manuals Search And Download.
(6 Ton)
Standard Efficiency
Performance
Data
Table PD-29 — Belt Drive Evaporator Fan Performance — 6-Ton — TSC072,AK — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
RPM BHP
1.00
RPM BHP
CFM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
2-HPStandardMotor&FieldSuppliedLowStaticDrive(1)
2-HPStandardMotor&Drive
1920
2160
2400
2640
2880
-
-
-
-
-
-
-
573
602
635
670
706
0.34
0.42
0.52
0.64
0.78
630
656
682
715
749
0.41
0.50
0.60
0.72
0.86
680
706
732
758
789
0.48
0.58
0.69
0.81
0.96
726
751
777
802
830
0.55
0.65
0.77
0.91
1.06
769
792
818
845
870
0.62
0.73
0.86
1.01
1.16
811
832
856
883
909
0.70
0.81
0.95
1.10
1.27
851 0.78
871 0.90
893 1.04
919 1.20
945 1.37
889 0.87
908 0.99
930 1.13
953 1.29
979 1.48
548
584
621
660
0.35
0.45
0.56
0.69
-
569
612
0.47
0.60
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
2-HPFanMotorHeat(MBH)=3.000xFanBHP+.5000
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
Table PD-29 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
2-HPStandardMotor&Drive
1.20
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
BHP
RPM
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
2-HPStandard Motor&HighStaticDrive
1920
2160
2400
2640
2880
925
944
964
986
1011
0.95
1.08
1.22
1.39
1.58
960
978
998
1019
1043
1.03
1.17
1.32
1.49
1.69
994
1.11
1.26
1.42
1.60
1.79
1026
1043
1063
1082
1103
1.19
1.36
1.53
1.71
1.90
1057
1073
1092
1112
1133
1.27
1.44
1.63
1.81
2.02
1087
1104
1123
1141
1161
1.36
1.54
1.73
1.92
2.13
1116
1133
1151
1169
1190
1.44
1.63
1.83
2.03
2.26
1144
1162
1179
1198
-
1.52
1.72
1.93
2.15
-
1173 1.61
1189 1.81
1206 2.03
1225 2.26
1200 1.70
1216 1.91
1233 2.13
1010
1030
1051
1073
-
-
-
-
-
-
2-HPStandardMotor&HighStaticDrive
Table PD-30 — Belt Drive Evaporator Fan Performance — 6-Ton — TSC072,AK — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
RPM BHP
1.00
RPM BHP
CFM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
2-HPStandardMotor&FieldSuppliedLowStaticDrive(1)
2-HPStandardMotor&Drive
1920
2160
2400
2640
2880
-
-
565
609
660
710
762
0.31
0.41
0.54
0.68
0.86
627
663
701
745
795
0.39
0.48
0.60
0.76
0.94
679
716
751
788
828
0.45
0.57
0.69
0.83
1.02
726
762
798
833
869
0.52
0.64
0.78
0.93
1.11
771
804
839
875
911
0.60
0.72
0.87
1.04
1.21
814
843
877
914
950
0.69
0.80
0.95
1.13
1.33
857
883
914
949
986
0.77
0.90
1.04
1.22
1.44
899 0.85
922 0.99
950 1.14
984 1.31
1019 1.53
939 0.93
960 1.08
984 1.24
1016 1.42
1051 1.63
566
619
672
726
0.35
0.47
0.61
0.77
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
2-HPFanMotorHeat(MBH)=3.000xFanBHP+.5000
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrange
of our fan motors as shown in our tabular data will not result in nuisance
tripping or premature motor failure. Our product’s warranty will not be
affected.
Table PD-30 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
2-HPStandardMotor&Drive
1.20
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
BHP
RPM
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
2-HPStandard Motor&HighStaticDrive
1920
2160
2400
2640
2880
978
996
1020
1049
1081
1.02
1.17
1.35
1.53
1.74
1015
1034
1055
1081
1112
1.11
1.27
1.45
1.65
1.86
1051
1069
1089
1113
1141
1.20
1.36
1.55
1.76
1.97
1086
1103
1122
1144
1170
1.30
1.46
1.66
1.87
2.10
1118
1136
1154
1176
1199
1.39
1.56
1.76
1.98
2.22
1150
1169
1186
1.49
1.67
1.86
1180
1199
1216
1.58
1.77
1.97
1209
1229
1.68
1.88
1236 1.77
1258 1.98
1276 2.20
1263 1.86
-
-
-
-
-
-
-
-
1246 2.08
-
-
1207 2.10
1237 2.21
-
-
-
-
-
-
-
-
-
-
2-HPStandardMotor&HighStaticDrive
RT-PRC005-EN
31
Download from Www.Somanuals.com. All Manuals Search And Download.
(7½ Ton)
Standard Efficiency
Performance
Data
Table PD-31 — Belt Drive Evaporator Fan Performance — 7½-Ton — TSC090,092A3,A4,AW,AK — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
2-HP Standard Motor & Field Supplied Low Static Drive (1)
2-HP Standard Motor & Drive
2400
2700
3000
3300
3600
—
—
656
713
771
—
—
0.71
0.93
1.19
—
—
652
699
747
797
848
0.54
0.70
0.91
1.15
1.42
701
743
789
836
885
0.63
0.79
0.99
1.24
1.53
750
787
827
873
921
0.72
0.89
1.10
1.34
1.63
794
830
867
908
954
0.81
0.99
1.20
1.45
1.74
834
871
906
944
986
0.90
1.09
1.31
1.57
1.87
873
908
944
980
1019
0.98
1.19
1.43
1.69
1.99
909 1.08
943 1.29
980 1.54
1016 1.82
945 1.17
977 1.39
1013 1.65
1050 1.94
652
703
755
809
0.63
0.81
1.03
1.29
1052 2.13 1085 2.26
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories.
2-HPFanMotorHeat(MBH)=2.000xFanBHP+.5000.
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.4750.
1. FieldSuppliedMotorSheave1VL40Lx7/8andFan
SheaveAK71required.
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
Table PD-31 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
2-HPStandardMotor&Drive
1.20
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
BHP
RPM
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
2-HPStandard Motor&HighStaticDrive
Kit(or3-HPOversizedMotor&Drive)
2400
2700
3000
3300
3600
980
1010
1045
1.27
1.49
1.76
1013
1043
1076
1111
1.37
1.60
1.87
2.18
2.53
1046
1074
1105
1141
1177
1.47
1.71
1.98
2.30
2.66
1076
1105
1134
1168
1.57
1.82
2.09
2.42
1106
1134
1163
1197
1.68
1.93
2.21
2.55
1137
1163
1192
1.78
2.04
2.34
1166
1192
1.89
2.16
1194
1.99
1220 2.08 1248 2.19
1219 2.27 1246 2.39 1273 2.51
1219 2.45 1247 2.58 1272 2.71 1299 2.84
1249 2.79 1276 2.92 1301 3.06 1326 3.19
1283 3.19 1309 3.32
1081 2.06
1116 2.39
1222 2.66
1257 3.05
1148
1204 2.79
1232 2.93
—
—
—
—
3-HP Oversized Motor & Drive
Table PD-32 — Belt Drive Evaporator Fan Performance — 7½-Ton — TSC090,092A3,A4,AW,AK — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
2-HP Standard Motor & Field Supplied
2-HP Standard Motor & Drive
Low Static Drive (1)
2400
2700
3000
3300
3600
—
—
673
738
805
873
942
0.56
0.76
1.00
1.29
1.63
718
773
837
903
970
0.63
0.83
1.08
1.38
1.74
769
817
870
930
996
0.72
0.92
1.17
1.47
1.84
814
862
912
963
1021
0.82
1.02
1.26
1.57
1.94
855
904
951
1000 1.68
1052 2.04
0.90
1.13
1.38
893
941
0.98
1.23
1.51
1.80
929
975
1025
1073
1121
1.08
1.32
1.62
1.94
2.29
965 1.18
1009 1.42
1056 1.72
1106 2.08
1153 2.44
999 1.29
1041 1.52
1088 1.82
1136 2.19
1184 2.59
702
771
842
913
0.68
0.91
1.19
1.53
989
1037
1086 2.16
3-HP Oversized Motor
& Drive
2-HPStandardMotor&HighStatic
Drive Kit (or 3-HP Oversized Motor)
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredrop
duetootheroptions/accessories
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
2-HPFanMotorHeat(MBH)=2.000xFanBHP+.5000.
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.4750.
1. FieldSuppliedMotorSheave1VL40Lx7/8andFanSheaveAK71required.
Table PD-32 — Continued
External Static Pressure (Inches ofWater)
1.10
BHP
1.20
BHP
1.30
BHP
1.40
1.50
1.60
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
RPM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM BHP
RPM BHP
2-HP Standard Motor & High Static Drive Kit
(or 3-HP Oversized Motor & Drive)
2-HP Standard Motor & Drive
2400
2700
3000
3300
3600
1035
1073
1117
1165
1.39
1.64
1.93
2.30
1070
1104
1146
1194
1.50
1.76
2.05
2.41
1104
1136
1176
1220 2.52
1269 2.98
1.60
1.87
2.17
1137
1167
1205 2.31
1248 2.66
1295 3.10
1.70
1.99
1168
1198
1.81
2.11
1201
1.92
1232 2.03 1261 2.14 1291 2.26 1319 2.38
1258 2.34 1287 2.46 1315 2.58 1343 2.69
1289 2.69 1317 2.82 1344 2.95 1372 3.08
1228 2.22
1261 2.56
1301 2.93
1345 3.35
1233 2.44
1275 2.79
1319 3.22
1326 3.07 1352 3.22 1378 3.36
—
—
—
—
1215 2.73
1242 2.86
—
—
—
—
—
—
3-HP Oversized Motor & Drive
RT-PRC005-EN
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(8½ Ton)
Standard Efficiency
Table PD-33— Belt Drive Evaporator Fan Performance — 8½-Ton — TSC102A3,A4,AW, AK —DownflowAirflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
2-HP Standard Motor & Field Supplied
2-HP Standard Motor
& Drive
Low Static Drive (1)
2720
3060
3400
3740
4080
—
—
—
622
671
—
—
—
0.76
0.96
—
—
612
659
706
—
—
0.68
0.86
1.08
—
—
613
650
689
729
770
0.60
0.74
0.91
1.10
1.32
655
688
724
764
804
0.72
0.85
1.02
1.23
1.46
695
725
759
795
834
0.84
0.98
1.15
1.35
1.60
733
761
792
826
864
0.95
1.11
1.29
1.49
1.74
769
796
825
857
892
1.08
1.25
1.43
1.64
1.88
802 1.21
828 1.38
856 1.58
887 1.79
920 2.04
833 1.34
861 1.52
887 1.72
916 1.96
948 2.20
611
651
693
738
0.64
0.79
0.97
1.19
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostnadardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
2-HPFanMotorHeat(MBH)=2.000xFanBHP+.5000.
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.4750.
1. FieldSuppliedFanSheaveAK79andBeltAX38required.
Table PD-33 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
2-HPStandardMotor&Drive
1.20
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
BHP
RPM
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
3-HPOversizedMotor&Drive
2720
3060
3400
3740
4080
863
891
917
945
976
1.48
1.66
1.87
2.11
2.38
892
919
946
974
1.63
1.81
2.03
2.28
920
946
974
1001 2.44
1029 2.73
1.78
1.96
2.18
946
973
1001 2.34
1028 2.61
1055 2.91
1.93
2.12
973
999
1026 2.52
1054 2.78
1081 3.09
2.08
2.29
999
2.24
1025 2.39
1048 2.63
1074 2.86
1050 2.55
1072 2.80
1099 3.05
1073 2.71
1096 2.98
1121 3.23
—
—
1098 2.88
1119 3.14
1143 3.41
1024 2.46
1051 2.69
1079 2.96
1103
1130
3.14
3.45
1126
—
3.32
—
—
—
—
—
—
—
1002 2.56
1105
3.26
Table PD-34 — Belt Drive Evaporator Fan Performance — 8½-Ton — TSC102A3,A4,AW, AK —Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
2-HP Standard Motor & Field Supplied
2-HP Standard Motor & Drive
Low Static Drive (1)
2720
3060
3400
3740
4080
—
—
598
654
711
770
828
0.57
0.77
1.01
1.30
1.65
646
693
743
799
857
0.67
0.86
1.10
1.40
1.76
689
735
781
830
883
0.78
0.98
1.22
1.51
1.86
734
773
819
865
913
0.90
1.10
1.36
1.65
1.99
781
812
853
899
945
1.04
1.23
1.49
1.79
2.15
826
855
886
930
977
1.18
1.39
1.62
1.94
865
897
925
960
1.31
1.55
1.79
2.09
898 1.44
934 1.70
964 1.97 1000 2.14
994 2.26 1028 2.44
928 1.56
969 1.85
616
675
735
796
0.69
0.92
1.20
1.53
2.30 1006 2.47 1034 2.63 1061 2.79
3-HP Oversized Motor & Drive
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
2-HPFanMotorHeat(MBH)=2.000xFanBHP+.5000.
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.4750.
1. FieldSuppliedFanSheaveAK79andBeltAX38required.
Table PD-34 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
2-HPStandardMotor&Drive
1.20
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
BHP
RPM
1008
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
3-HPOversizedMotor&Drive
2720
3060
3400
3740
4080
956
999
1.67
1.99
2.32
2.63
2.99
982
1.79
1.91
1033 2.03
1078 2.39
1056 2.14
1079 2.26
1102
1146
1191
—
2.38
2.79
3.24
—
1125
1168
2.50
2.92
1146 2.62
1188 3.05
—
—
—
1168 2.74
1209 3.18
1026 2.12
1067 2.49
1098 2.84
1052 2.26
1094 2.64
1101
1145
1185
—
2.52
2.94
3.39
—
1124
1168
—
2.66
3.09
—
1034
1063
1093
1120
1158
—
2.79
3.21
—
1213 3.39
—
—
—
—
—
—
—
—
—
—
—
1129
1157
3.03
3.40
—
—
1125
3.19
—
—
—
—
RT-PRC005-EN
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(10 Ton)
Standard Efficiency
Table PD-35 — Belt Drive Evaporator Fan Performance — 10-Ton — TSC120A3,A4,AW,AK — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
3-HP Standard Motor & Field Supplied
Low Static Drive (1)
3200
3600
4000
4400
4800
—
—
—
741
803
—
—
—
1.27
1.62
—
—
715
773
833
—
—
1.09
1.40
1.76
—
—
747
803
861
—
—
1.21
1.53
1.90
—
—
718
764
814
864
916
0.97
1.20
1.49
1.82
2.20
754
797
844
894
945
1.10
1.33
1.63
1.98
2.38
789
829
874
922
972
1.25
1.48
1.77
2.13
2.55
822
860
903
948
997
1.38
1.63
1.93
2.28
856 1.53
892 1.79
932 2.09
887 1.67
922 1.95
960 2.27
731
782
834
887
1.08
1.35
1.67
2.04
975 2.44 1001 2.62
2.71 1022 2.87 1046 3.04
3-HP Standard Motor & Drive
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredrop
duetootheroptions/accessories
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.475.
5-HPFanMotorHeat(MBH)=2.950xFanBHP+.470.
1. FieldSuppliedMotorSheave1VM50x7/8”,FanSheaveAK89 andBeltAX40required.
Table PD-35 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
1.20
BHP
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
RPM
RPM
BHP RPM RPM
3-HPStandardMotor&Drive
973 2.14 999 2.30
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
3200
3600
4000
4400
4800
917
951
988
1.82
2.11
2.44
945
979
1.97
2.27
1015 2.62
1053 3.00
1095 3.42
1024 2.47
1059 2.78
1093 3.15
1048 2.65
1082 2.95
1072 2.82
1095 3.00
1117 3.17
1152 3.52
1187 3.91
1140 3.36
1173 3.71
1209 4.11
1007 2.43
1042 2.79
1078 3.19
1033 2.60
1068 2.97
1107
1142
1176
3.14
3.52
3.96
1130
1164
1198
3.33
3.70
1117
1152
1189
3.33
3.77
4.25
1028 2.81
1071 3.23
1103
1142
3.38
3.83
1128
1166
3.57
4.04
4.15 1221 4.36 1243 4.56
1119
3.62
1212 4.46 1233 4.66 1256 4.88 1277 5.09
5-HP Oversized Motor & Drive
Table PD-36— Belt Drive Evaporator Fan Performance — 10-Ton — TSC120A3,A4,AW,AK — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
3-HP Standard Motor & Field Supplied
Low Static Drive (1)
3200
3600
4000
4400
4800
—
—
—
—
730
792
860
931
1.00
1.32
1.73
2.24
771
829
890
955
1.13
1.45
1.86
2.35
807
865
923
983
1.26
1.60
2.01
2.49
844
898
956
1014
1.39
1.74
2.17
2.66
886
930
986
1.55
1.89
2.32
926
965
1015
1.72
965 1.89 1000 2.06
729
802
876
950
1.13
1.52
1.99
2.56
761
833
905
977
1.22
1.63
2.12
2.70
2.06 1002 2.24 1038 2.43
2.48 1044 2.65 1077 2.85
1045 2.84 1072 3.01
1102 3.43 1131 3.63
1098 3.18
1156 3.81
1125 3.36
1181 4.00
1002 2.84
1025 2.96
1048 3.08
1074 3.24
3-HP Standard Motor & Drive
5-HP Oversized Motor & Drive
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
For Standard Evaporator Fan Speed (RPM), reference Table PD-48.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.475.
5-HPFanMotorHeat(MBH)=2.950xFanBHP+.470.
1. FieldSuppliedMotorSheave1VM50x7/8”,Fan
SheaveAK89 andBeltAX40required.
Table PD-36 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
3-HPStandardMotor&Drive
1.20
1.30
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
BHP
RPM
BHP
RPM
BHP RPM RPM
BHP
BHP
RPM
1177
BHP
RPM BHP
RPM BHP
3200
3600
4000
4400
4800
1029 2.20
1072 2.62
1057 2.35
1084 2.49
1108
1160
1204 3.68
1241 4.21
1280 4.81
2.63
3.15
1132
1185
1232 3.88
1270 4.44
1309 5.06
2.77
3.31
1155
2.91
3.05
1198
3.18 1219 3.32 1239 3.46
1106
1143
1182
2.81
3.26
3.76
1134
1174
1211
2.98
3.47
3.99
1209 3.47
1260 4.09
1299 4.68
1336 5.31
1231 3.63 1252 3.78 1274 3.94 1295 4.10
1283 4.27 1306 4.46 1327 4.63 1349 4.81
1327 4.91 1352 5.14 1377 5.37 1400 5.57
1111
1152
3.05
3.55
1205 4.19
1229 4.39
1253 4.58
1363 5.56
—
—
—
—
—
—
5-HP Oversized Motor & Drive
RT-PRC005-EN
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(3, 4, 5Ton)
High Efficiency
Table PD-37— Direct Drive Evaporator Fan Performance — 3, 4, and 5 Ton — THC036A, THC048A,
THC060A
External Static Pressure (Inches ofWater) & Motor Power (Bhp)1
Standard Motor
High Speed Low Speed
Oversized Motor
Unit
High Speed Low Speed
Tons Model No.
CFM
ESP
BHP
ESP
BHP
ESP
BHP
ESP
BHP
960
0.74
0.69
0.65
0.61
0.55
0.51
0.46
0.41
0.34
0.36
0.37
0.38
0.39
0.40
0.41
0.42
0.43
0.44
0.56
0.49
0.44
0.37
0.29
0.19
0.10
0.00
—
0.28
0.28
0.29
0.29
0.30
0.30
0.31
0.31
—
0.89
0.85
0.82
0.77
0.74
0.70
0.67
0.64
0.57
0.38
0.39
0.41
0.43
0.44
0.45
0.47
0.48
0.51
0.82
0.77
0.74
0.69
0.65
0.61
0.57
0.52
0.45
0.35
0.36
0.38
0.40
0.41
0.42
0.44
0.45
0.48
1020
1080
1140
1200
1260
1320
1380
1440
3
4
5
3
4
5
THC036A
Horizontal
1280
1360
1440
1520
1600
1680
1760
1840
1920
1600
1700
1800
1900
2000
2100
2200
2300
2400
0.90
0.83
0.76
0.69
0.60
0.51
0.42
0.31
0.21
1.04
0.97
0.92
0.82
0.74
0.64
0.51
0.42
0.31
0.79
0.74
0.70
0.66
0.60
0.56
0.51
0.46
0.39
0.95
0.88
0.81
0.74
0.65
0.56
0.47
0.36
0.26
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.78
0.80
0.85
0.88
0.90
0.93
0.94
0.95
0.97
0.36
0.37
0.38
0.39
0.40
0.41
0.42
0.43
0.44
0.53
0.54
0.54
0.55
0.55
0.56
0.56
0.57
0.57
0.79
0.71
0.65
0.56
0.44
0.32
0.17
0.05
—
0.94
0.81
0.70
0.61
0.45
0.30
0.15
—
0.47
0.47
0.48
0.48
0.49
0.49
0.50
0.50
—
0.64
0.65
0.65
0.65
0.66
0.66
0.67
—
1.16
1.11
1.06
1.01
0.94
0.89
0.84
0.75
0.67
1.37
1.29
1.21
1.20
1.03
0.94
0.83
0.73
0.60
0.94
0.90
0.87
0.82
0.79
0.75
0.72
0.69
0.62
1.21
1.16
1.11
1.06
0.99
0.94
0.89
0.80
0.72
1.42
1.34
1.26
1.25
1.08
0.99
0.88
0.78
0.65
0.67
0.68
0.70
0.73
0.75
0.78
0.82
0.83
0.85
0.90
0.94
0.98
1.02
1.05
1.10
1.12
1.17
1.20
0.38
0.39
0.41
0.43
0.44
0.45
0.47
0.48
0.51
0.67
0.68
0.70
0.73
0.75
0.78
0.82
0.83
0.85
0.95
0.90
0.85
0.77
0.68
0.59
0.42
0.29
0.18
1.23
1.13
1.02
0.92
0.81
0.68
0.47
0.23
—
0.82
0.82
0.79
0.74
0.70
0.66
0.62
0.57
0.50
1.00
0.95
0.90
0.82
0.73
0.64
0.47
0.34
—
0.56
0.58
0.60
0.63
0.64
0.66
0.68
0.70
0.73
0.85
0.89
0.91
0.94
0.95
0.96
0.96
0.97
—
0.35
0.36
0.38
0.40
0.41
0.42
0.44
0.45
0.48
0.56
0.58
0.60
0.63
0.64
0.66
0.68
0.70
—
THC048A
Horizontal
THC060A
Horizontal
—
—
960
0.56
0.54
0.49
0.42
0.34
0.24
0.15
0.05
—
0.84
0.76
0.70
0.61
0.49
0.37
0.22
0.10
—
0.99
0.86
0.75
0.66
0.50
0.35
0.20
—
0.28
0.28
0.29
0.29
0.30
0.30
0.31
0.31
—
0.47
0.47
0.48
0.48
0.49
0.49
0.50
0.50
—
0.64
0.65
0.65
0.65
0.66
0.66
0.67
—
1020
1080
1140
1200
1260
1320
1380
1440
1280
1360
1440
1520
1600
1680
1760
1840
1920
1600
1700
1800
1900
2000
2100
2200
2300
2400
THC036A
Downflow
THC048A
Downflow
1.09
1.02
0.97
0.87
0.79
0.69
0.56
0.47
0.36
0.78
0.80
0.85
0.88
0.90
0.93
0.94
0.95
0.97
0.90
0.94
0.98
1.02
1.05
1.10
1.12
1.17
1.20
1.28
1.18
1.07
0.97
0.86
0.73
0.52
0.28
—
0.85
0.89
0.91
0.94
0.95
0.96
0.96
0.97
—
THC060A
Downflow
—
—
Fan motor heat (MBH) = 3.72 x Fan Bhp + .24.
Trane’s factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate
reliably and continuously at all cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will
not result in nuisance tripping or premature motor failure. Our product’s warranty will not be affected.
NOTE:
1. Data includes pressure drop due to wet coil and filters.
2. 5 ton oversized motor performance is with 12 x 11 FC blower wheel.
RT-PRC005-EN
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(3 Ton)
High Efficiency
Table PD-38 — Belt Drive Evaporator Fan Performance — 3 Ton — THC036A3,A4,AW — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor
& Field Supplied
Low Static Drive (1)
1-HP Standard Motor & Drive
960
—
—
—
552
588
—
—
—
0.18
0.23
528
557
588
622
657
0.12
0.15
0.19
0.23
0.28
599
625
652
681
713
0.16
0.19
0.23
0.27
0.33
658
685
712
738
765
0.20
0.24
0.28
0.32
0.37
713
738
764
790
817
0.24
0.28
0.33
0.38
0.43
763
786
811
838
865
0.29
0.33
0.38
0.44
0.50
810
832
856
882
909
0.33
0.38
0.43
0.49
0.56
855
876
898
923
949
0.38
0.43
0.48
0.55
0.62
898 0.43
917 0.48
939 0.54
962 0.60 1000 0.66
987 0.68 1024 0.74
939 0.49
957 0.54
978 0.59
1080
1200
1320
1440
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1. FieldSuppliedFanSheaveAK69required. FieldSuppliedBeltmaybenecessary.
2. FieldSuppliedFanSheaveAK41required.FieldSuppliedBeltmaybenecessary.
Table PD-38 — Continued
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
BHP
BHP
BHP
BHP
1-HPStandardMotor&Drive
960
978
995
1015
1036
1060
0.54
0.59
0.65
0.72
0.80
1016 0.60
1033 0.65
1051 0.71
1072 0.78
1094 0.86
1052 0.66
1069 0.71
1086 0.77
1106
1128
1086 0.72
1120
1136
1154
1171
1192
0.78
0.84
0.91
0.98
1.07
1080
1200
1320
1440
1103
1120
1138
1160
0.78
0.84
0.91
1.00
0.85
0.93
1-HPStandardMotor&
Field Supplied High Static Drive (2)
Table PD-39— Belt Drive Evaporator Fan Performance — 3 Ton — THC036A3,A4,AW — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
960
—
—
588
622
654
687
723
0.15
0.18
0.23
0.28
0.33
661
694
727
760
793
0.19
0.24
0.28
0.34
0.40
725
756
787
821
855
0.24
0.29
0.34
0.40
0.47
782
813
843
875
908
0.29
0.34
0.40
0.46
0.53
832
864
895
925
956
0.35
0.40
0.46
0.53
0.60
878
910
942
973
0.40
0.46
0.52
0.59
919
954
986
1017
0.46
0.52
958 0.51
996 0.56
1080
1200
1320
1440
531
570
610
651
0.13
0.17
0.22
0.27
993 0.59 1031 0.65
0.59 1026 0.66 1064 0.73
0.66 1058 0.73 1095 0.81
1003 0.67 1047 0.75 1088 0.82
1127 0.89
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1-HPStandardMotor&
Field Supplied High Static Drive (2)
1. FieldSuppliedFanSheaveAK69required. FieldSuppliedBeltmaybenecessary.
2. FieldSuppliedFanSheaveAK41required.FieldSuppliedBeltmaybenecessary.
Table PD-39— Continued
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
BHP
BHP
BHP
BHP
1-HPStandardMotor&Drive
960
1032
1065
1099
1132
1164
0.62
0.70
0.80
0.88
0.97
1066 0.67
1099 0.76
1133
1167
1199
1101
0.73
0.82
0.93
1.04
1.14
1133
1164
1197
1230
1263
0.79
0.89
0.99
1.11
1.22
1166
1194
1227
1261
1294
0.86
0.95
1.06
1.19
1.30
1080
1200
1320
1440
1132
1166
1200
1232
0.86
0.96
1.05
1-HPStandardMotor&
Field Supplied High Static Drive (2)
RT-PRC005-EN
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(4 Ton)
High Efficiency
Table PD-40 — Belt Drive Evaporator Fan Performance — 4 Ton — THC048A3,A4,AW — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
1280
1440
1600
1760
1920
—
—
626
674
724
775
825
0.23
0.30
0.38
0.48
0.59
686
730
776
825
875
0.27
0.34
0.44
0.54
0.66
744
783
825
870
918
0.32
0.39
0.49
0.60
0.73
796
834
872
915
959
0.38
0.45
0.54
0.66
0.79
843
882
919
958
0.43
0.52
0.61
0.72
885
924
962
999
0.49
0.58
927
964
0.54
967 0.60 1005 0.66
609
661
716
771
0.24
0.32
0.42
0.53
0.64 1002 0.70 1038 0.76
0.68 1002 0.75 1039 0.82 1076 0.89
0.79 1040 0.87 1078 0.95
1116 1.09
1113 1.03
1151 1.17
1000 0.86
1039 0.92 1078 1.00
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1. FieldSuppliedFanSheaveAK61required. FieldSuppliedBeltmaybenecessary.
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
Table PD-40 — Continued
External Static Pressure (Inches ofWater)
1.10
RPM
1.20
RPM BHP
1.30
RPM
1.40
RPM
1.50
CFM
BHP
1-HPStandardMotor&Drive
BHP
BHP
RPM
BHP
1280
1440
1600
1760
1920
1041 0.72
1074 0.83
1109
1147
1186
1076
1108
1142
1179
1218
0.78
0.89
1.02
1.17
1.34
1110
0.84
0.96
1.09
1.25
1.42
1143
1174
1207
1241
—
0.91
1.03
1.17
1.32
—
1176
1205
1236
—
0.98
1.10
1.24
—
1141
1175
1211
1249
0.95
1.10
1.26
—
—
Table PD-41 — Belt Drive Evaporator Fan Performance — 4 Ton —THC048A3,A4,AW — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
1280
1440
1600
1760
1920
617
674
733
793
853
0.21
0.29
0.38
0.49
0.62
696
745
799
854
911
0.27
0.35
0.45
0.56
0.70
767
815
862
911
964
0.34
0.42
0.53
0.65
0.79
826
874
922
969
1018
0.40
0.49
0.60
0.73
0.88
879
925
975
1023 0.82
1069 0.97
0.46
0.56
0.68
930
974
0.52
0.63
976
0.59 1020 0.66 1060 0.73 1098 0.80
1020 0.70 1064 0.77
1104 0.85
1147 0.99
1191 1.15
1239 1.34
1142 0.92
1186 1.07
1230 1.24
1275 1.43
1020 0.75
1069 0.90
1065 0.83
1107
1152
1201
0.91
1.07
1.25
1112
1161
0.98
1.15
1118
1.06
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1-HPStandardMotor&Field
Supplied High Static Drive (2)
1. FieldSuppliedFanSheaveAK61required. FieldSuppliedBeltmaybenecessary.
2. FieldSuppliedFanSheaveAK41required. FieldSuppliedBeltmaybenecessary.
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
Table PD-41 — Continued
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM BHP RPM RPM
1.10
RPM
1.50
RPM BHP
CFM
BHP
BHP
BHP
1-HPStandardMotor
1280
1440
1600
1760
1920
1132
1179
1223 1.15
1267 1.33
0.88
1.01
1167
1213
1258 1.24
1301
—
0.95
1.09
1199
1.03
1245 1.17
1291 1.33
1231
1.10
1277 1.26
1322 1.42
1260 1.17
1307 1.34
—
—
—
—
—
—
1.42
—
—
—
—
—
—
—
—
—
—
—
1-HP Standard Motor &
Field Supplied High Static Drive(2)
RT-PRC005-EN
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(5 Ton)
High Efficiency
Table PD-42— Belt Drive Evaporator Fan Performance — 5 Ton — THC060A3,A4,AW — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
1600
1800
2000
2200
2400
—
—
703
760
821
885
950
0.36
0.47
0.62
0.80
1.02
757
815
873
930
990
0.41
0.54
0.69
0.87
1.08
806
861
918
977
1034
0.47
0.60
0.76
0.95
1.16
854
904
958
1016
1074
0.52
0.66
0.83
1.03
1.25
899
947
998
1053
1110
0.58
0.72
0.90
1.10
1.00
944
988
0.65
985
0.73 1023 0.79 1060 0.86
706
773
840
909
0.42
0.57
0.75
0.96
0.78 1028 0.86 1067 0.94
1104 1.02
1147 1.19
1191 1.39
1036 0.96 1073
1.02
1.24
1.50
1111 1.10
1158 1.31
—
1089
1143
1.17
1.42
1124
1177
—
—
—
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
1. FieldSuppliedFanSheaveAK56required. FieldSuppliedBeltmaybenecessary.
Table PD-42 — Continued
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
BHP
BHP
BHP
BHP
1-HPStandardMotor&Drive
1600
1800
2000
2200
2400
1093 0.92
1126
1171
1215
—
0.99
1.17
1.37
—
1160
1.06
1.25
1.46
—
1190
1232
—
—
—
1.13
1.32
—
—
—
1222
1262
—
—
—
1.20
1.39
—
—
—
1138
1182
1226
—
1.10
1.28
1.48
—
1203
1246
—
—
—
—
—
PD-43 — Belt Drive Evaporator Fan Performance — 5 Ton — THC060A3,A4,AW — Downflow Airflow — Dehumidification (Hot Gas Reheat)
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
1-HPStandardMotor&Low
StaticDriveAccessoryKit(2)
RPM
BHP
RPM
BHP
RPM
BHP
RPM BHP
RPM BHP
1-HP Standard Motor & Low
1-HPStandard
Motor&Drive
Static Drive Accessory Kit (1)
1000
1200
1400
1600
—
—
537
588
645
703
0.13
0.19
0.26
0.36
608
652
702
757
0.17
0.23
0.31
0.41
667
712
756
806
0.21
0.28
0.36
0.47
721
764
808
854
0.25
0.33
0.41
0.52
770
811
856
899
0.30
0.38
0.48
0.58
817
856
900
944
0.35
0.43
0.54
0.65
861
898
941
985
0.39
0.48
0.59
0.73
905 0.45
944 0.50
978 0.59
1017 0.71
1060 0.86
517
576
640
0.15
0.21
0.31
939 0.54
979 0.65
1023 0.79
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 1600 CFM.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Datadoesnotincludepressuredropduetoreheatcoil.
1HPFanMotorHeat(MBH)=2.829xFanBHP+.4024.
1. BAYLSDR008ARequired.
Trane’s factory supplied motors, in commercial equipment, are
definite purpose motors, specifically designed and tested to
operate reliably and continuously at all cataloged conditions.
Using the full horsepower range of our fan motors as shown in
our tabular data will not result in nuisance tripping or premature
motor failure. Our product’s warranty will not be affected.
2. BAYLSDR008ARequired.
PD-43 — Continued
External Static Pressure (Inches ofWater)
1.10
RPM
1.20
RPM BHP
1.30
RPM BHP
1.40
RPM
1.50
RPM
CFM
BHP
BHP
BHP
1-HPStandardMotor&Drive
1000
1200
1400
1600
985
0.56
1021 0.62
1051 0.71
1088 0.84
1058 0.68
1086 0.77
1121
1160
1093 0.74
1126
1154
1185
1222
0.80
0.91
1.04
1.20
1015 0.65
1052 0.77
1093 0.92
1120
1153
1190
0.84
0.97
1.13
0.90
1.06
1126
0.99
RT-PRC005-EN
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(5 Ton)
High Efficiency
Table PD-44 — Belt Drive Evaporator Fan Performance — 5 Ton — THC060A3,A4,AW — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
1600
1800
2000
2200
2400
707
778
850
923
997
0.35
0.48
0.65
0.84
1.07
774
840
908
978
1049
0.42
0.56
0.73
0.93
1.17
837
897
961
1028
1096
0.50
0.64
0.81
1.02
1.27
898
953
1012
1075
1140
0.57
0.72
0.90
1.12
1.37
953
1008 0.81
1062 1.00
1120
1183
0.65
1001 0.72
1058 0.89
1045 0.80 1087 0.87
1129 0.95
1181 1.15
1237 1.37
1168 1.03
1219 1.23
1274 1.47
1102
1157
1211
—
0.98
1.19
1.43
—
1143
1198
—
1.06
1.28
—
1111
1166
—
1.09
1.32
—
1.22
1.48
—
—
—
—
—
—
—
—
—
—
Trane’sfactorysuppliedmotors,incommercial
equipment, are definite purpose motors,
specifically designed and tested to operate
reliably and continuously at all cataloged
conditions. Using the full horsepower range of our
fan motors as shown in our tabular data will not
result in nuisance tripping or premature motor
failure. Our product’s warranty will not be
affected.
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
FanMotorHeat(MBH)=2.829xFanBHP+.4024.
1. FieldSuppliedFanSheaveAK56required. FieldSuppliedBeltmaybenecessary.
Table PD-44 — Continued
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM BHP RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
BHP
BHP
BHP
1-HPStandardMotor
1600
1800
2000
2200
2400
1206 1.12
1256 1.32
1241 1.20
1291 1.41
1275 1.28
1326 1.50
—
—
—
1306 1.37
1338 1.46
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Table PD-45— Belt Drive Evaporator Fan Performance — 5 Ton — THC060A3,A4,AW — Horizontal Airflow — Dehumidification (Hot Gas Reheat)
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
1-HPStandardMotor&Low
StaticDriveAccessoryKit(2)
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM BHP
RPM BHP
1-HP Standard Motor & Low
Static Drive Accessory Kit (1)
1-HP Standard Motor & Drive
1000
1200
1400
1600
507
570
638
707
0.11
0.17
0.25
0.35
599
654
711
774
0.16
0.23
0.31
0.42
671
727
782
837
0.21
0.28
0.38
0.50
735
787
844
898
0.26
0.34
0.44
0.57
792
843
896
953
0.31
0.40
0.51
0.65
843
895
946
0.37
0.46
0.58
889
942
993
0.42
0.52
0.65
931
986
1037 0.72
1087 0.87
0.48
0.59
971 0.54
1026 0.66
1078 0.79
1129 0.95
1007 0.59
1064 0.73
1117 0.86
1168 1.03
1001 0.72
1045 0.80
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 1600 CFM.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Datadoesnotincludepressuredropduetoreheatcoil.
1HPFanMotorHeat(MBH)=2.829xFanBHP+.4024.
1. BAYLSDR008ARequired.
Trane’s factory supplied motors, in commercial equipment,
are definite purpose motors, specifically designed and
tested to operate reliably and continuously at all cataloged
conditions. Using the full horsepower range of our fan
motors as shown in our tabular data will not result in
nuisance tripping or premature motor failure. Our product’s
warranty will not be affected.
2. BAYLSDR008ARequired.
Table PD-45 — Continued
External Static Pressure (Inches ofWater)
1.20 1.30 1.40
RPM BHP RPM RPM
1.10
RPM
1.50
RPM
CFM
BHP
BHP
1-HPStandardMotor&Drive
BHP
BHP
1000
1200
1400
1600
1042
1099
1153
1206
0.65
0.80
0.94
1.12
1078 0.70
1110
1166
1221
1275
0.76
0.93
1.10
1.28
1142
1197
1253
1306
0.82
0.99
1.18
1.37
1175
1227
1284
1338
0.89
1.06
1.27
1.46
1133
1188
1241
0.86
1.02
1.20
RT-PRC005-EN
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(6 Ton)
High Efficiency
Table PD-46— Belt Drive Evaporator Fan Performance — 6 Ton — THC072A3,A4,AW* — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
1-HP Standard Motor & Drive
Low Static Drive (1)
1920
2160
2400
2640
2880
—
—
—
589
634
—
—
—
0.50
0.63
—
—
588
618
652
690
728
0.35
0.44
0.54
0.67
0.82
643
672
701
734
770
0.43
0.52
0.63
0.76
0.91
693
721
750
779
810
0.50
0.60
0.72
0.85
1.01
738
765
794
822
851
0.57
0.68
0.81
0.95
1.11
782
806
834
864
892
0.65
0.76
0.90
1.05
1.22
823
847
873
901
930
0.73
0.85
0.98
1.15
1.33
862 0.81
885 0.93
909 1.08
936 1.24
965 1.44
900 0.89
922 1.02
945 1.17
971 1.34
999 1.54
564
602
642
682
0.37
0.47
0.59
0.74
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredrop
duetootheroptions/accessories
1-HPFanMotorHeat(MBH)=2.829xFanBHP+.4024.
2-HPFanMotorHeat(MBH)=3.000xFanBHP+.5000
1. FieldSuppliedFanSheaveAK84andBeltAX34required.
Table PD-46 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
1.20
BHP
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
RPM
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
1-HPStandard
Motor&Drive
1-HP Standard Motor & High Static Drive Kit
(or2HPOversizedMotor&Drive)
1920
2160
2400
2640
2880
937
0.98
1.12
1.27
1.44
1.64
971
1.06
1.21
1.37
1.55
1.75
1004
1024
1046
1067
1092
1.14
1.30
1.47
1.65
1.86
1037
1057
1076
1098
1123
1.22
1.40
1.57
1.77
1.98
1068
1087
1106
1129
1151
1.30
1.49
1.68
1.88
2.09
1097
1.38
1.58
1.78
1.99
2.22
1127
1146
1166
1185
—
1.47
1.67
1.89
2.10
—
1154
1174
1194
1214 2.22
—
1.55
1.76
1.99
1182 1.64
1201 1.85
1220 2.08
1210 1.74
1227 1.95
1248 2.19
957
980
1004
1030
991
1117
1137
1158
1181
1013
1036
1061
—
—
—
—
—
—
—
—
—
2-HPOversizedMotor&Drive
Table PD-47 — Belt Drive Evaporator Fan Performance — 6 Ton — THC072A3,A4,AW — Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
1-HP Standard Motor & Field Supplied
Low Static Drive (1)
1-HP Standard Motor & Drive
1920
2160
2400
2640
2880
—
—
580
623
673
725
778
0.33
0.43
0.56
0.71
0.90
641
679
718
762
811
0.41
0.51
0.63
0.79
0.98
692
731
769
808
848
0.47
0.59
0.72
0.87
1.06
738
775
814
853
891
0.54
0.67
0.82
0.98
1.16
783
817
855
894
932
0.63
0.74
0.90
1.09
1.28
827
857
893
931
970
0.71
0.83
0.98
1.17
1.40
870
896
929
966
0.79
0.93
1.08
912 0.88
935 1.02
965 1.18
951 0.96
974 1.12
999 1.29
1032 1.47
1068 1.69
578
633
688
743
0.37
0.49
0.64
0.81
1.26 1000 1.36
1037 1.59
1004 1.49
2-HP Oversized
Motor & Drive
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredrop
duetootheroptions/accessories
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
1-HPStandardMotor&HighStatic
Drive Kit (or 2-HP Oversized Motor)
1-HPFanMotorHeat(MBH)=2.829xFanBHP+.4024.
2-HPFanMotorHeat(MBH)=3.000xFanBHP+.5000
1. FieldSuppliedFanSheaveAK84andBeltAX34required.
2. FieldSuppliedFanSheaveAK54andBeltAX30.
Table PD-47 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
1.20
BHP
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
RPM
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
1.71
RPM BHP
RPM BHP
1-HP Standard
Motor & Drive
1-HPStandard Motor&HighStaticDriveKit
(or2HPOversizedMotor&Drive)
1920
990
1010
1035
1065
1099
1.05
1026
1047
1070
1097
1130
1.14
1.31
1.50
1.71
1.93
1062
1082
1104
1129
1159
1.24
1.40
1.60
1.82
2.05
1096
1116
1137
1161
1188
1.33
1.50
1.70
1.93
2.18
1130
1.43
1.61
1.81
2.05
1160
1182
1201
1.52
1.71
1.92
1190
1211
1.61
1.81
1218
1242 1.92
1247 1.80
1271 2.03 1298 2.14
1273 1.90
2160
2400
2640
2880
1.21
1.39
1.59
1.80
1150
1168
1192
1232 2.03 1261 2.14 1291 2.26
1252 2.27
—
—
2-HPOversizedMotor&
Field Supplied Drive (2)
1223 2.16
—
—
—
—
1217 2.30
—
—
—
—
2-HP Oversized Motor & Drive
RT-PRC005-EN
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(7½Ton)
High Efficiency
Table PD-48 — Belt Drive Evaporator Fan Performance — 7½-Ton — THC092A3,A4,AW — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
2-HP Standard Motor & Field Supplied
Low Static Drive (1)
2400
2700
3000
3300
3600
—
—
—
—
—
—
—
—
—
—
—
—
—
604
639
675
—
—
0.61
0.74
0.89
583
611
643
678
713
0.50
0.60
0.71
0.86
1.02
627
653
682
713
748
0.61
0.71
0.83
0.97
1.14
669
693
719
748
780
0.72
0.83
0.95
1.09
1.26
708
731
755
783
811
0.83
0.95
1.08
1.23
1.40
743
768
791
815
844
0.95
1.07
1.21
1.37
1.55
776 1.08
801 1.20
824 1.35
848 1.52
874 1.70
808 1.21
832 1.33
856 1.48
880 1.66
904 1.86
—
—
601
—
0.68
599
640
0.63
0.79
2-HP Standard Motor & Drive
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
2-HPFanMotorHeat(MBH)=2.000xFanBHP+.5000.
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.4750
1. FieldSuppliedFanSheaveAK79andBeltAX38required.
Table PD-48— Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
2-HP Standard Motor & Drive
1.20
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
BHP
RPM
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
2400
2700
3000
3300
3600
839
862
886
910
933
1.34
1.48
1.63
1.81
2.01
868
891
915
939
962
1.48
1.62
1.78
1.96
2.17
898
918
942
967
990
1.61
1.77
1.93
2.12
2.33
926
946
968
993
1.75
1.92
2.09
2.28
953
971
1.89
2.07
2.25
2.45
980
998
2.04
2.23
2.42
1006 2.18
1023 2.38
1044 2.59
1066 2.79
1091 3.02
1032 2.34
1049 2.54
1067 2.75
1091 2.98
1056 2.49
1074 2.70
1092 2.93
1113 3.15
1137 3.39
1080 2.64
1097 2.86
1115 3.09
1136 3.34
1158 3.58
994
1019
1019
1042 2.66
3-HPOversizedMotor&Drive
1043 2.62
1067 2.84
1016 2.49
1114
3.21
Table PD-49 — Belt Drive Evaporator Fan Performance — 7½-Ton — THC092A3,A4,AW—Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
2-HP Standard Motor & Field Supplied
Low Static Drive (1)
2400
2700
3000
3300
3600
—
—
605
658
711
—
—
0.65
0.84
1.07
—
—
603
644
684
728
776
0.52
0.66
0.82
1.02
1.27
653
686
726
767
809
0.63
0.77
0.94
1.15
1.38
707
732
765
805
846
0.75
0.89
1.06
1.28
1.52
754
780
806
840
880
0.88
1.03
1.20
1.40
1.66
792
824
849
876
912
0.99
1.17
1.35
1.55
1.80
825
863
891
916
943
1.09
1.30
1.51
1.71
1.95
857 1.19
895 1.42
929 1.66
955 1.89
980 2.13
886 1.30
925 1.54
962 1.80
991 2.06
1016 2.30
595
644
694
746
0.56
0.73
0.93
1.18
2-HP Standard Motor & Drive
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
2-HPFanMotorHeat(MBH)=2.000xFanBHP+.5000.
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.4750
1. FieldSuppliedFanSheaveAK79andBeltAX38required..
Table PD-49 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
1.20
BHP
2-HPStandardMotor&Drive
1.30
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
RPM
BHP
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
2400
2700
3000
3300
3600
913
954
992
1.40
1.66
1.94
941
981
1019
1055 2.38
1085 2.69
1.51
1.77
2.07
966
1.61
991
1030 2.00
1069 2.32
1108
1144
1.71
1017
1054 2.12
1094 2.46
1132
1170
1.82
1040
1077 2.24
1116
1156
1193
1.92
1064 2.04 1087 2.14
1110 2.26
1144 2.60
1181 2.97 1202 3.10
1132 2.37
1164 2.71
1006 1.89
1045 2.20
1082 2.53
1100
1138
1178
—
2.36
2.71
3.11
—
1121
1160
2.47
2.84
2.58
2.96
3.37
1025 2.22
1052 2.50
2.67
3.05
2.82
3.21
1200 3.25 1221 3.39
—
—
—
—
—
1117
2.88
—
—
—
3-HP Oversized Motor & Drive
RT-PRC005-EN
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(8½ Ton)
High Efficiency
Table PD-50— Belt Drive Evaporator Fan Performance — 8½-Ton — THC102A3,A4,AW — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
2-HP Standard Motor & Field Supplied
LowStaticDrive(1)
2720
3060
3400
3400
4080
--
--
--
641
693
--
--
--
0.81
1.03
--
--
584
626
669
713
758
0.53
0.68
0.84
1.04
1.27
626
665
706
749
792
0.64
0.78
0.96
1.17
1.41
668
703
741
781
824
0.76
0.90
1.08
1.30
1.56
708
740
775
813
854
0.88
1.04
1.21
1.43
1.69
746
775
809
845
883
1.00
1.17
1.36
1.58
1.83
781
810
841
875
912
1.12
1.30
1.51
1.73
1.99
814 1.26
843 1.44
873 1.65
905 1.89
940 2.16
845 1.40
875 1.58
904 1.81
935 2.06
968 2.33
--
--
628
677
726
0.72
0.92
1.15
2-HPStandardMotor&Drive
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
2-HPFanMotorHeat(MBH)=2.000xFanBHP+.5000.
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.4750
1. FieldSuppliedFanSheaveAK79andBeltAX38required.
Table PD-50 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
1.20
BHP
2-HPStandardMotor&Drive
1.30
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
RPM
BHP
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
2720
3060
3400
3400
4080
874
905
933
964
995
1.54
1.73
1.96
2.22
2.51
904
933
962
992
1.69
1.89
2.11
2.39
930
960
990
1018 2.55
1048 2.86
1.84
2.05
2.27
958
986
1016 2.44
1045 2.72
1075 3.05
2.00
2.20
983
2.14
1010 2.30
1035 2.54
1065 2.79
1095 3.08
1035 2.46
1059 2.71
1089 2.97
1060 2.62
1083 2.89
1084 2.78
1107 3.06
1134 3.34
1109 2.95
1131 3.24
1010 2.37
1041 2.62
1071 2.90
1112
1141
--
3.15
3.45
--
--
--
--
--
--
--
1118
--
3.26
--
--
--
--
--
1023 2.69
1100
3.23
1124
3.41
3-HPOversizedMotor&Drive
Table PD-51 — Belt Drive Evaporator Fan Performance — 8½-Ton — THC102A3,A4,AW —Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
2-HP Standard Motor & Field Supplied
Low Static Drive (1)
2720
3060
3400
3740
4080
—
—
612
667
726
786
848
0.60
0.80
1.05
1.36
1.72
660
709
760
815
874
0.71
0.91
1.15
1.46
1.83
703
750
800
850
903
0.81
1.03
1.29
1.59
1.95
751
788
836
886
935
0.95
1.15
1.42
1.74
2.10
798
830
870
918
968
1.09
1.29
1.56
1.88
2.26
841
873
907
949
998
1.23
1.45
1.71
2.03
877
914
945
980
1.36
1.62
1.88
2.19
909 1.48
951 1.77
984 2.06 1020 2.24
1015 2.37 1052 2.57
939 1.60
983 1.92
631
692
754
817
0.72
0.96
1.26
1.61
2.42 1026 2.58 1054 2.75 1085 2.94
2-HP Standard Motor & Drive
3-HP Oversized Motor & Drive
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
2-HPFanMotorHeat(MBH)=2.000xFanBHP+.5000.
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.4750
1. FieldSuppliedFanSheaveAK79andBeltAX38required.
Table PD-51 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
2-HPStandardMotor&Drive
1.20
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
BHP
RPM
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
2720
3080
3400
3740
4080
967
1.72
2.06
994
1.84
1018
1.96
1042 2.07
1090 2.46
1066 2.19
1089 2.31
1112
1158
2.43
2.86
1204 3.33
1134
1179
—
2.55
2.99
—
1155 2.67
1199 3.12 1220 3.26
—
—
—
1176 2.79
1012
1039 2.19
1083 2.58
1065 2.32
1113
1159
—
2.59
3.04
—
1136
1183
—
2.73
3.19
—
1052 2.41
1086 2.77
1109
1149
—
2.73
3.15
—
1135
1178
—
2.88
3.34
—
—
—
—
—
—
—
—
—
—
1119
1151
2.96
3.36
—
—
—
—
—
—
—
—
1117
3.14
—
—
—
—
3-HP Oversized Motor & Drive
RT-PRC005-EN
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(10 Ton)
High Efficiency
Table PD-52— Belt Drive Evaporator Fan Performance — 10-Ton — THC120A3,A4,AW — Downflow Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
3-HP Standard Motor & Field Supplied Low Static Drive (1)
3200
3600
4000
4400
4800
—
—
—
—
—
—
734
795
857
—
—
1.16
1.49
1.88
—
—
—
—
734
782
834
888
942
1.03
1.27
1.58
1.95
2.36
770
815
863
916
970
1.17
1.41
1.72
2.10
2.53
804
847
894
943
996
1.31
1.57
1.87
2.25
839
879
923
970
1.45
1.73
2.04
2.41
871 1.60
909 1.89
952 2.21
901 1.74
939 2.04
979 2.39
714
768
825
884
1.02
1.30
1.63
2.02
749
803
857
913
1.14
1.44
1.79
2.18
—
—
764
828
1.36
1.74
997 2.59 1024 2.78
2.70 1021 2.86 1045 3.03 1070 3.22
3-HPStandardMotor&Drive
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.475.
5-HPFanMotorHeat(MBH)=2.950xFanBHP+.470.
1. FieldSuppliedMotorSheave1VM50x7/8inch,FanSheaveAK89,
andBeltAX40required.
Table PD-52 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
1.20
BHP
1.30
BHP
2.22
1.70
BHP
1084 2.91
1.80
RPM
1.90
2.00
CFM
RPM
RPM
RPM
986
RPM
BHP RPM BHP RPM BHP
RPM
BHP
RPM BHP
RPM BHP
3200
3600
4000
4400
4800
931
969
1.89
2.21
1007 2.57
1050 2.97
1095 3.42
959
997
2.06
2.37
1034 2.74
1075 3.17
1012 2.39
1050 2.72
1037 2.56
1074 2.89
1061 2.74
1098 3.08
1108
1145
1182
1219
3.09
3.46
3.86
4.34
1131 3.28
1166 3.65
1204 4.07
1241 4.54
1280 5.12
1153 3.46
1188 3.85
1226 4.28
1264 4.77
1300 5.32
1024 2.54
1062 2.93
1122
1159
1198
3.27
3.66
4.15
1087
1126
1166
3.11
3.55
4.05
1112
1150
1189
3.29
3.75
4.26
1136
1173
3.47
3.94
1101
1143
3.36
3.83
1119
3.62
1212 4.47
1235 4.68
1258 4.90
5-HPOversizedMotor&Drive
Table PD-53— Belt Drive Evaporator Fan Performance—10-Ton— THC120A3,A4,AW— Downflow Airflow— Dehumidification (Hot Gas Reheat)
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM BHP
RPM BHP
3-HPStandardMotor&Low
StaticDriveAccessoryKit(1)
3-HPStandardMotor&Low
StaticDriveAccessoryKit(2)
2000
2400
2800
3200
—
—
—
—
—
—
—
—
564
618
—
—
0.50
0.67
—
—
607
659
—
—
0.60
0.79
568
606
649
697
0.43
0.56
0.71
0.90
613
650
689
734
0.53
0.67
0.83
1.03
653
691
728
770
0.64
0.78
0.95
1.17
691
728
766
804
0.75
0.90
1.08
1.31
727
763
801
839
0.86
1.02
1.21
1.45
763 0.98
796 1.16
833 1.35
871 1.60
797 1.10
826 1.29
864 1.50
901 1.74
576
0.57
Trane’sfactorysuppliedmotors,incommercial
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
equipment,aredefinitepurposemotors,specifically
designedandtestedtooperatereliablyand
continuouslyatallcatalogedconditions.Usingthefull
horsepowerrangeofourfanmotorsasshowninour
tabular data will not result in nuisance tripping or
premature motor failure. Our product’s warranty will
notbeaffected.
NOTES:
Data includes pressure drop due to standard filters and wet coils.
Data does not include pressure drop due to reheat coil.
3-HP Fan Motor Heat (MBH) = 2.900 x Fan BHP+.475.
1. BAYLSDR010ARequired.
2. BAYLSDR010ARequired.
Table PD-53 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
1.20
BHP
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
RPM
RPM
BHP RPM BHP RPM BHP
RPM
BHP
RPM BHP
RPM BHP
3 HP Standard Motor & Drive
2000
2400
2800
3200
828
858
894
931
1.22
1.43
1.65
1.89
859
888
921
959
1.35
1.56
1.79
2.06
888
916
949
986
1.48
1.70
1.95
2.22
917
945
975
1.61
1.85
2.11
945
972
1.75
1.99
971
998
1027 2.43
1061 2.74
1.88
2.14
998
2.03
1023
1050 2.45
1076 2.75
2.19
1048 2.35
1073 2.60
1100 2.92
1131 3.28
1072 2.50
1097 2.76
1123 3.09
1023 2.29
1051 2.59
1084 2.91
1001 2.27
1037 2.56
1012 2.39
1108
3.09
—
—
RT-PRC005-EN
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
(10 Ton)
High Efficiency
Table PD-54— Belt Drive Evaporator Fan Performance — 10-Ton — THC120A3,A4,AW —Horizontal Airflow
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP
RPM BHP RPM BHP RPM BHP RPM BHP
3-HP Standard Motor & Field Supplied
3-HP Standard Motor
& Drive
Low Static Drive (1)
3200
3600
4000
4400
4800
—
—
—
—
748
811
879
950
1.06
1.39
1.81
2.32
787
849
912
977
1.19
1.54
1.95
2.46
824
883
946
1008 2.63
1072 3.23
1.32
1.68
2.12
864
916
977
1039 2.81
1101 3.42
1.47
1.82
2.28
906
950
1.64
1.98
946
987
1.81
983 1.97
1015 2.13
746
822
898
974
1.18
1.59
2.09
2.69
777
850
925
1.27
1.70
2.21
2.16 1024 2.35 1060 2.55
1006 2.43 1035 2.60 1067 2.79
1067 2.98 1094 3.16 1121 3.33
1130 3.62 1156 3.81
5-HP Oversized Motor & Drive
1101 2.99
1147 3.52
1181 4.00 1206 4.19
1000 2.83
1023 2.95
1046 3.07
Trane’sfactorysuppliedmotors,incommercialequipment,aredefinitepurpose
motors,specificallydesignedandtestedtooperatereliablyandcontinuouslyat
allcatalogedconditions.Usingthefullhorsepowerrangeofourfanmotorsas
shown in our tabular data will not result in nuisance tripping or premature motor
failure.Ourproduct’swarrantywillnotbeaffected.
ForStandardEvaporatorFanSpeed(RPM),referenceTablePD-50.
NOTES:
Dataincludespressuredropduetostandardfiltersandwetcoils.
Noaccessoriesoroptionsareincludedinpressuredropdata.
RefertoTablePD-54todetermineadditionalstaticpressuredropduetootheroptions/accessories
3-HPFanMotorHeat(MBH)=2.900xFanBHP+.475.
5-HPFanMotorHeat(MBH)=2.950xFanBHP+.470.
1. FieldSuppliedMotorSheave1VM50x7/8inch,FanSheaveAK89,
andBeltAX40required
Table PD-54 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
1.20
BHP
3-HPStandardMotor&Drive
1.30
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
RPM
BHP
RPM
BHP RPM RPM
BHP
BHP
RPM
1189
BHP
RPM BHP
RPM BHP
3200
3600
4000
4400
4800
1044 2.28
1093 2.74
3.21
3.73
1229 4.39
1072 2.42
1097 2.57
1122
1176
1227 3.84
1268 4.42
1310 5.07
2.71
3.25
1145
2.84
1168
2.99
3.12 1210 3.27 1231 3.41 1250 3.54
1124
1167
1207 3.96
1254 4.59
2.92
3.42
1151
1198
1239 4.19
1282 4.83
3.09
3.63
1201 3.42
1254 4.05
1297 4.67
1338 5.32
1224 3.58
1278 4.23
1324 4.90
1365 5.58
1246 3.74 1268 3.90 1289 4.06 1308 4.20
1301 4.41 1323 4.60 1344 4.77 1365 4.95
1351 5.12 1376 5.35 1398 5.56 1420 5.75
1135
1177
—
—
—
—
—
—
—
—
5-HP Oversized Motor & Drive
Table PD-55— Belt Drive Evaporator Fan Performance — 10-Ton — THC120A3,A4,AW —Horizontal Airflow — Dehumidification (Hot Gas Reheat)
External Static Pressure (Inches ofWater)
.10
.20
.30
.40
.50
.60
.70
.80
.90
1.00
CFM
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM
BHP
RPM BHP
RPM BHP
3-HPStandardMotor&Low
3-HPStandardMotor&Low
StaticDriveAccessoryKit(2)
StaticDriveAccessoryKit(1)
2000
2400
2800
3200
—
—
596
671
—
—
0.58
0.85
—
—
584
627
686
748
0.43
0.57
0.79
1.06
639
683
728
787
0.53
0.70
0.90
1.19
682
734
776
824
0.62
0.83
1.04
1.32
721
776
822
864
0.71
0.94
1.19
1.47
755
812
865
906
0.79
1.05
1.34
1.64
787
845
900
946
0.88
1.15
1.47
1.81
818 0.97
876 1.26
932 1.60
983 1.97
849 1.06
904 1.36
962 1.73
1015 2.13
578
640
706
0.48
0.67
0.93
3-HPOversizedMotor&Drive
***MINIMUM AIR VOLUME REQUIRED FOR USE WITH OPTIONAL ELECTRIC HEAT IS 3200 CFM.
Trane’sfactorysuppliedmotors,incommercial
equipment,aredefinitepurposemotors,specifically
designedandtestedtooperatereliablyand
continuouslyatallcatalogedconditions.Usingthefull
horsepowerrangeofourfanmotorsasshowninour
tabular data will not result in nuisance tripping or
premature motor failure. Our product’s warranty will
notbeaffected.
NOTES:
Data includes pressure drop due to standard filters and wet coils.
Data does not include pressure drop due to reheat coil.
3-HP Fan Motor Heat (MBH) = 2.900 x Fan BHP+.475.
1. BAYLSDR010ARequired.
2. BAYLSDR010ARequired.
Table PD-55 — Continued
External Static Pressure (Inches ofWater)
1.40 1.50 1.60
1.10
BHP
1.20
BHP
1.30
BHP
1.70
BHP
1.80
RPM
1.90
2.00
CFM
RPM
RPM
RPM
RPM
BHP RPM RPM
BHP
BHP
RPM
BHP
RPM BHP
RPM BHP
3-HPStandardMotor&Low
StaticDriveAccessoryKit(2)
3-HPStandardMotor&Drive
2000
2400
2800
3200
877
931
989
1.15
1.47
1.84
906
958
1015
1.24
1.58
1.97
933
983
1040 2.09
1097 2.57
1.33
1.68
961
1.43
1.78
988
1.54
1.89
1014
1.64
1038
1080
1132
1189
1.74
2.11
2.58
3.12
1063
1103
1154
1.85
2.22
2.71
1087 1.96
1126 2.34
1176 2.83
1111 2.07
1149 2.46
1196 2.95
1008
1032
1087 2.34
1145 2.84
1056 2.00
1064 2.21
1122 2.71
1110
1168
2.46
2.99
1044 2.28
1072 2.42
1210 3.27
—
—
—
—
RT-PRC005-EN
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
Table PD-56— Standard Motor & Sheave/Fan Speed (Rpm)
Unit
Model No.
6Turns
Open
5Turns
Open
4Turns
Open
3Turns
Open
2Turns
Open
1Turn
Open
Tons
3
4
5
6
7½
8½
10
Closed
1117
1250
1346
1002
1113
T#C036A
T#C048A
T#C060A
T#C072A
TSC090,092A
T#C102A
T#C120A
NA
NA
NA
N/A
N/A
N/A
N/A
745
833
897
723
835
787
908
819
916
987
779
891
847
969
894
1000
1077
835
946
908
968
1083
1166
890
1002
968
1043
1167
1256
946
1057
1029
1150
1089
1211
1029
1090
Factory set at 3 turns open.
Table PD-57— Standard Motor & High Static DriveAccessory Sheave/Fan Speed (Rpm)
Unit
Model No.
6Turns
Open
5Turns
Open
4Turns
Open
3Turns
Open
2Turns
Open
1Turn
Open
Tons
6
6
Closed
1150
1278
1278
T#C072A3,A4,AW
TSC072AK
TSC090,092A
N/A
N/A
N/A
831
958
958
895
1022
1022
959
1086
1086
1022
1150
1150
1086
1214
1214
7½
Factory set at 3 turns open.
Table PD-58— Oversized Motor & Drive Sheave/Fan Speed (Rpm)
Unit
Model No.
T#C072A3,A4,AW
6Turns
Open
N/A
5Turns
Open
958
4Turns
Open
1022
3Turns
Open
1086
2Turns
Open
1150
1Turn
Open
1214
Tons
6
7½
8½
10
Closed
1278
1479
1278
N/A
TSC090,092A
T#C102A
T#C120A
N/A
N/A
1050
1068
958
1135
1150
1022
1200
1232
1086
1275
1315
1150
1350
1397
1214
1425
Factory set at 3 turns open.
Table PD-59— Outdoor Sound Power Level - dB (ref. 10 -12 Watts)
Unit
Octave Center Frequency
Overall
Tons
3
Model No.
T*C036A
63.
86
125
83
250
81
500
80
1000
78
2000
74
4000
69
8000
68
dBA
83
TSC048A1
TSC048A3,A4,AW
THC048A
92
90
92
87
84
86
84
78
83
83
77
82
81
76
81
76
72
75
72
70
72
69
68
69
86
82
85
4
TSC060A
THC060A
94
94
87
87
83
82
82
81
79
78
75
74
73
72
69
69
84
84
5
TSC072A
THC072A
90
91
94
95
90
90
87
87
83
84
78
79
74
75
67
68
88
89
6
TSC090A
TSC092A
THC092A
92
89
92
95
93
96
91
88
92
88
85
89
84
81
85
80
76
80
75
72
76
68
66
69
90
87
91
7½
TSC102A
THC102A
TSC120A
THC120A
88
91
91
94
92
95
88
89
87
90
84
87
84
87
82
85
80
84
81
84
75
79
76
78
72
75
73
75
65
68
67
69
86
89
86
88
8½
10
Note:
Tests follow ARI270-95.
# Indicates both Standard and High Efficiency.
RT-PRC005-EN
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
Table PD-60 — Static Pressure DropsThroughAccessories (InchesWater Column) — 3 - 10 Tons
Economizer with
Electric Heater
Unit
Model No.
Standard Through
2 Inch
Pleated Filters 100% OA 100% RA 100%OA 100%RA
Downflow Horizontal
0.05 0.05
OA/RA Dampers2
Accessory (kW)3
Tons
CFM
Filters1
Reheat
5-6
9-15
17-36
54
Coil (WC)
960
0.03
0.04
0.06
0.02
0.03
0.04
0.04
0.05
0.08
0.10
0.15
0.22
—
—
—
0.04
—
0.06
—
0.09
0.04
0.06
0.09
0.06
0.10
0.14
0.04
0.06
0.09
0.05
0.08
0.12
0.07
0.11
0.16
—
—
—
—
—
—
—
—
—
—
0.05
0.07
0.10
0.04
0.05
0.07
0.06
0.09
0.12
0.15
0.22
0.29
—
0.01
0.02
0.03
0.01
0.02
0.03
0.03
0.04
0.06
0.04
0.07
0.10
—
0.00
0.01
0.01
0.00
0.01
0.01
0.01
0.01
0.02
0.01
0.02
0.04
—
.013
.020
.029
.013
.020
.029
.023
.036
.052
.036
.056
.081
—
.016
.025
.036
.016
.025
.036
.029
.045
.064
.045
.070
.100
—
.019
.030
.043
.019
.030
.043
.034
.053
.077
.053
.083
.120
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
TSC036A
THC036A
T#C048A
TSC060A
1200
1440
960
0.07
0.10
0.05
0.07
0.10
0.08
0.12
0.17
0.12
0.18
0.26
—
0.07
0.10
0.05
0.07
0.10
0.08
0.12
0.17
0.12
0.18
0.26
—
3
4
1200
1440
1280
1600
1920
1600
2000
2400
1000
1200
1400
1600
1800
2000
2200
2400
1920
2400
2880
2400
3000
3600
2400
3000
3600
2720
3400
4080
3200
4000
4800
2000
2400
2800
3200
3600
4000
4400
4800
—
—
—
.03
.04
.05
.07
.09
.10
.12
.14
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
0.07
—
0.10
—
—
—
0.12
—
0.18
—
—
—
0.04
—
0.07
—
—
—
0.12
—
0.18
—
—
—
0.01
—
0.02
—
—
—
.036
—
.056
—
—
—
.045
—
.070
—
—
—
.053
—
.083
—
5
THC060A
0.14
0.07
0.09
0.12
0.09
0.13
0.18
0.06
0.09
0.13
0.08
0.11
0.16
0.10
0.15
0.20
—
0.26
0.10
0.11
0.13
0.11
0.14
0.21
0.11
0.14
0.21
0.12
0.19
0.30
0.17
0.26
0.34
—
0.10
0.01
0.02
0.04
0.02
0.05
0.07
0.02
0.05
0.07
0.03
0.06
0.07
0.05
0.07
0.09
—
0.26
0.06
0.08
0.10
0.08
0.12
0.25
0.08
0.12
0.25
0.09
0.18
0.31
0.14
0.30
0.35
—
0.04
0.02
0.02
0.04
0.02
0.05
0.08
0.02
0.05
0.08
0.04
0.06
0.09
0.05
0.08
0.10
—
.081
0.02
0.02
0.04
0.02
0.05
0.08
0.02
0.05
0.08
0.04
0.06
0.09
0.05
0.08
0.10
—
.100
0.011
0.020
0.033
0.020
0.042
0.077
0.016
0.025
0.036
0.020
0.032
0.047
0.028
0.045
0.065
—
.120
0.021
0.034
0.052
0.034
0.063
0.102
0.021
0.032
0.046
0.026
0.041
0.059
0.036
0.056
0.081
—
6
T#C072A
TSC090, 092A
THC092A
7½
8½
10
T#C102A
0.042
0.070
0.106
—
—
—
0.042
—
0.070
—
0.106
T#C120A
—
—
0.09
0.10
0.13
0.15
0.19
0.22
0.27
0.31
—
—
0.07
—
0.11
—
—
0.10
—
0.15
—
—
0.17
—
0.26
—
—
0.05
—
0.07
—
—
0.14
—
0.30
—
—
0.05
—
0.08
—
—
0.05
—
0.08
—
—
0.028
—
0.045
—
—
0.036
—
0.056
10
THC120A
—
0.16
—
0.20
—
0.34
—
0.09
—
0.35
—
0.10
—
0.10
—
0.065
—
0.081
NOTES:
Table PD-61— Electric HeaterVoltage
Correction Factors (Applicable to
Auxiliary Heat Capacity)
1. Tested with standard filters (3-5 tons 1" filters, 6-10 tons 2” filters). Difference in
pressure drop should be considered when utilizing optional 2”pleated filters.
2. OA = Outside Air and RA = Return Air.
3. Nominal kW ratings at 240, 480, 600 volts.
Nominal
Voltage
Distribution
Voltage
Capacity
Multiplier
208
230
240
380
440
460
480
540
575
600
0.751
0.918
1.000
1.000
0.840
0.918
1.000
0.810
0.918
1.000
240
380
480
600
RT-PRC005-EN
46
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
Table PD-62— Auxiliary Electric Heat Capacity
Total2
Stage1
Stage 2
Unit
Model No.
kW
MBH
No. of
Stages
kW
MBH
kW
MBH
Tons
3
Input1
Output1
Input1
Output1
Input1
Output1
5.00
10.00
13.80
17.07
34.14
47.11
1
2
2
5.00
5.00
8.80
17.07
17.07
30.04
—
5.00
5.00
—
17.07
17.07
T#C036A1
6.00
12.00
17.40
5.00
10.00
13.80
17.60
6.00
12.00
17.40
5.00
10.00
13.80
17.60
6.00
20.48
40.97
59.40
17.07
34.14
47.11
60.09
20.48
40.97
59.40
17.07
34.14
47.11
60.09
20.48
40.97
59.40
78.52
25.61
37.23
49.18
30.73
61.45
92.18
122.90
38.60
57.72
77.18
30.73
61.45
92.18
122.90
38.60
57.72
77.18
30.73
61.45
92.18
122.90
30.73
61.45
92.18
122.90
57.72
77.18
61.45
92.18
122.90
184.36
57.72
77.18
115.43
1
2
2
1
2
2
2
1
2
2
1
2
2
2
1
2
2
2
2
2
2
1
1
2
2
1
2
2
1
1
2
2
1
2
2
1
1
2
2
1
1
2
2
2
2
1
2
2
2
2
2
2
6.00
6.00
8.70
5.00
5.00
8.80
8.80
6.00
6.00
8.70
5.00
5.00
8.80
8.80
6.00
6.00
8.70
20.48
20.48
29.70
17.07
17.07
30.04
30.04
20.48
20.48
29.70
17.07
17.07
30.04
30.04
20.48
20.48
29.70
48.82
11.10
18.61
24.59
30.73
61.45
61.45
61.45
38.60
38.60
38.60
30.73
61.45
61.45
61.45
38.60
38.60
38.60
30.73
61.45
61.45
61.45
30.73
61.45
61.45
61.45
38.60
38.60
61.45
61.45
61.45
122.90
38.60
38.60
76.84
—
6.00
8.70
—
5.00
5.00
8.80
—
6.00
8.70
—
5.00
5.00
8.80
—
6.00
8.70
8.70
3.25
5.45
7.20
—-
—
T#C036A3, A4, AW
20.48
29.69
—
17.07
17.07
30.04
—
20.48
29.70
—
17.07
17.07
30.04
—
20.48
29.70
29.70
11.10
18.61
24.59
—-
T#C048A1
4
5
T#C048A3, A4, AW
T#C060A1
T#C060A3, A4, AW
12.00
17.40
23.00
7.50
10.90
14.4
14.30
3.25
5.45
7.20
9.00
TSC060AK
9.00
T#C072A3, A4, AW
18.00
27.00
36.00
11.30
16.90
22.60
9.00
18.00
27.00
36.00
11.30
16.90
22.60
9.00
18.00
18.00
18.00
11.30
11.30
11.30
9.00
18.00
18.00
18.00
11.30
11.30
11.30
9.00
—-
—-
6
9.00
18.00
—
5.60
11.30
—-
30.73
61.45
—
19.13
38.60
—-
TSC072AK
T#SC090A3, A4, AW
—-
—-
9.00
18.00
—
5.60
11.30
—-
30.73
61.45
—
19.13
38.60
—-
7 1/2
TSC090AK
T#C092A3, A4, AW
18.00
27.00
36.00
9.00
18.00
18.00
18.00
9.00
—-
—-
9.00
18.00
—-
30.73
61.45
—-
8 1/2
T#C102A3, A4, AW
TSC102AK
18.00
27.00
36.00
16.90
22.60
18.00
27.00
36.00
54.00
16.90
22.60
33.80
18.00
18.00
18.00
11.30
11.30
18.00
18.00
18.00
36.00
11.30
11.30
22.50
—-
—-
9.00
18.00
5.60
11.30
—-
9.00
18.00
18.00
11.30
11.30
11.30
30.73
61.45
19.13
38.60
—-
30.73
61.45
61.45
38.60
38.60
38.60
10
T#C120A3, A4, AW
TSC120AK
NOTES:
1. Does not include indoor fan power or heat.
2. Heaters are rated at 240v, 380v, 480v. and 600v. For other than rated voltage, CAP =
2
Voltage
Rated Voltage
x rated cap.
(
)
RT-PRC005-EN
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Performance
Data
Table PD-63 — 3-5TonsAirTemperature RiseAcross Electric Heaters (Degrees F)
3 Ton
4 Ton
5 Ton
1
1200 CFM
1600 CFM
2000 CFM
Single Phase
Stages T#C036A1
Three Phase
T#C036A3,A4,AW
Single Phase
T#C048A1
Three Phase
T#C048A3,A4,AW
Single Phase
T#C060A1
Three Phase
kW
5.00
6.00
7.50
10.00
10.90
12.00
13.80
14.40
17.40
17.60
23.00
T#C060A3,A4,AW
TSC060AK
1
1
2
2
2
2
2
2
2
2
2
13.2
—
—
26.3
—
—
36.4
—
—
—
—
15.8
—
—
—
31.6
—
—
45.8
—
9.9
—
—
19.8
—
—
27.3
—
—
34.8
—
—
11.9
—
—
—
23.7
—
—
34.4
—
7.9
—
—
15.8
—
—
21.8
—
—
27.8
—
—
9.5
—
—
—
19.0
—
—
27.5
—
—
—
11.9
—
17.2
—
—
22.8
—
—
—
—
—
—
36.4
For minimum design airflow, see airflow performance table for each unit.
To calculate temp rise at different air flow, use following formula:
NOTE:
KW x 3414
1.08 x CFM
Temp. Rise across Elect. Htr =
1. Minimum allowable aiflow with a 17.4 or 17.6 KW heater is 1440 cfm.
Table PD-64 — 6-10TonsAirTemperature RiseAcross Electric Heaters (Degrees F)
6Ton
2000 CFM
7½Ton
3000 CFM
8½Ton
3400 CFM
10 Ton
4000 CFM
1
T#C090A3, A4, AW
kW
9.00
Stages T#C072A3, A4, AW TSC072AK T#C092A3, A4, AW
TSC090AK T#C102A3, A4, AW TSC102AK T#C120A3,A4,AW TSC120AK
1
1
2
1
2
2
2
2
2
14.2
—
—
28.5
—
42.7
—
56.9
—
—
14.9
22.3
—
29.8
—
—
—
—
9.5
—
—
19.0
—
28.5
—
37.9
—
—
11.9
17.8
—
23.8
—
8.4
—
—
16.7
—
25.1
—
—
15.7
—
21.0
—
—
—
—
14.2
—
21.3
—
—
13.4
—
17.9
—
11.30
16.90
18.00
22.60
27.00
33.80
36.00
54.00
—
—
—
—
33.5
—
—
—
—
—
28.5
42.7
26.7
—
—
For minimum design airflow, see airflow performance table for each unit.
kW x 3414
1.08 x CFM
To calculate temp rise at different air flow, use following formula:
NOTE:
Temp. Rise across Elect. Htr =
1. Minimum allowable aiflow with a 17.4 or 17.6 KW heater is 1440 cfm.
Table PD-65— Hot Gas ReheatTemperature Rise3
SCFM
Leaving Evaporator Dry Bulb [F]
5Tons
1000
1200
1400
1600
1800
2000
2200
2400
35
40
45
50
55
60
65
23.7
22.6
21.4
20.3
19.1
17.9
16.8
15.6
23.6
22.4
21.2
20.1
18.9
17.8
16.6
15.4
23.4
22.2
21.0
19.9
18.7
17.6
16.4
15.2
23.2
22.0
20.9
19.7
18.5
17.4
16.2
15.1
23.0
21.8
20.7
19.5
18.4
17.2
16.0
14.9
22.8
21.6
20.4
19.3
18.1
16.9
15.7
14.6
22.5
21.3
20.2
19.0
17.8
16.6
15.4
14.3
10Tons
2000
2400
2800
3200
3600
4000
4400
4800
35
40
45
50
55
60
65
26.0
23.5
21.1
18.7
16.2
13.8
11.3
8.9
26.5
24.1
21.8
19.5
17.2
14.9
12.5
10.2
26.9
24.7
22.5
20.3
18.1
15.9
13.7
11.5
27.4
25.3
23.3
21.2
19.1
17.0
14.9
12.9
27.9
25.9
24.0
22.0
20.1
18.1
16.1
14.2
28.3
26.4
24.6
22.7
20.8
19.0
17.1
15.3
28.6
26.9
25.1
23.4
21.6
19.8
18.1
16.3
NOTES:
1. Temperature rise does not account for indoor fan heat.
2. 70 deg OD Ambient Temperature.
3. For units with the Dehumidification (Hot Gas Reheat) option.
RT-PRC005-EN
48
Download from Www.Somanuals.com. All Manuals Search And Download.
Zone Controls
ReliaTel™ Controlled Units
Zone Sensors are the building
occupant’s comfort control devices for
Precedent™ units with the Micro control:
Programmable Night Setback —
Auto or manual changeover with seven-
day programming. Keyboard selection
of Heat, Cool, Fan, Auto, or On. All
Electromechanically Controlled
Units
ConventionalThermostats are the
building occupant’s comfort control
devices for electromechanically
controlled units.
Manual
Changeover —
Heat, Cool or Off
System Switch. Fan
Auto or Off Switch.
One temperature
setpoint lever.
Manual Changeover — One Heat,
One Cool
Thermostat.
Heat, Cool or Off
System Switch.
Fan Auto or On
TM
Switch. Set Point
90
Dial. Adjustable
Heat Anticipator.
70
80
programmable sensors have System
On, Heat, Cool, Service LED/indicators as
standard. Night Setback Sensors have
one (1) Occupied, one (1) Un-occupied,
and two (2) Override programs per day.
Manual/Automatic Changeover —
Auto, Heat, Cool or Off System
Switch. Fan Auto
or Off Switch.Two
temperature
Automatic Changeover — One Heat,
Two CoolThermostat. Off, Auto System
Switch. Auto/On Fan Switch.
Humidity Sensor — Field installed,
wall-mounted
setpoint levers.
(BAYSENS036) or
Optional Status
duct-mounted
Indication LED
(BAYSENS037)
lights, System On,
Heat, Cool, or
HEAT
COOL
humidity sensor is
used to control
50 60 70 80
50 60 70 80
Service.
activation of the
50 60 70 80
hot gas reheat
dehumidification
TM
option.The
humidity sensor
FAN
AUTO
ON
OFF
AUTO
can be set for
humidity levels
Remote Sensor
— Sensor(s)
between 40% and 60% relative humidity
adjusting the ReliaTel Options Module.
available for all
zone sensors to
provide remote
sensing
Programmable Electronic Night Setback
Thermostat —
Heating setback
and cooling
setup with 7-day,
5-1-1
programming
capability.
Available inTwo
heating/cooling
or one heating/
cooling versions
with automatic changeover.
CO2 Sensing —The CO2 sensor shall
have the ability to to monitor space
occupancy levels within the building by
measuring the
capabilities.
parts per million
of CO2 (Carbon
Dioxide) in the
air. As the CO2
levels increase,
Integrated
ComfortTM System — Sensor(s)
available with
the outside air
damper
modulates to
optional
temperature
meet the CO2
space
adjustment and
override buttons to
provide central
control through a
Trane Integrated
ComfortTM system.
ventilation
requirements.
The CO2
accessory shall
be available as field installed.
RT-PRC005-EN
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
(Standard
Efficiency)
Table ED-1 — UnitWiring — Standard Efficiency
Optional
Standard Indoor Fan Motor
Oversize Indoor Fan Motor
Minimum Maximum Fuse
Circuit Size Or Maximum
Ampacity Circuit Breaker1
Belt Drive Indoor Fan Motor2
Minimum Maximum Fuse
Circuit Size or Maximum
Ampacity Circuit Breaker1
Unit
Operating
Voltage Range
187-253
Minimum Maximum Fuse
Circuit Size Or Maximum
Ampacity Circuit Breaker1
Unit
Tons
3
Model No.
TSC036A1
TSC036A3
TSC036A4
TSC036AW
25.3
17.9
9.2
40
25
15
15
27.7
20.3
10.4
8.3
40
30
15
15
N/A
20.6
10.6
8.3
N/A
30
15
187-253
414-506
517-633
7.7
15
TSC048A1
TSC048A3
TSC048A4
TSC048AW
TSC060A1
TSC060A3
TSC060A4
TSC060AW
TSC060AK
TSC072A3
TSC072A4
TSC072AW
TSC072AK
187-253
187-253
414-506
517-633
187-253
187-253
414-506
517-633
342-418
187-253
414-506
517-633
342-418
34.0
23.9
12.8
9.8
47.3
31.5
16.0
12.2
19.6
32.7
17.6
12.8
23.2
50
35
20
15
60
50
25
15
30
50
25
20
35
36.1
26.0
14.4
10.6
49.0
33.2
16.3
12.8
—
34.0
18.2
13.6
—
50
40
20
15
60
50
25
20
—
50
25
20
—
N/A
25.3
13.6
10.0
N/A
30.3
15.6
11.8
—
—
—
—
—
N/A
35
20
4
5
6
15
N/A
45
25
15
—
—
—
—
—
TSC090A3
TSC090A4
TSC090AW
TSC090AK
TSC092A3
TSC092A4
TSC092AW
TSC102A3
TSC102A4
TSC102AW
TSC102AK
TSC120A3
TSC120A4
187-253
414-506
517-633
342-418
187-253
414-506
517-633
187-253
414-506
517-633
342-418
187-253
414-506
42.7
22.6
17.6
28.4
38.9
20.5
15.5
45.1
24.0
19.5
32.6
52.6
26.9
60
35
25
40
50
25
20
60
30
25
40
60
35
45.8
24.1
18.8
29.9
42.0
22.0
16.7
48.2
25.5
20.7
35.6
56.6
28.9
60
35
25
45
50
25
20
60
35
25
45
60
35
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
7½
8½
10
TSC120AW
517-633
21.8
25
23.5
30
—
—
TSC120AK
342-418
32.6
40
35.6
45
—
—
NOTES:
1. HACR breaker per NEC.
2. Optional Belt Drive motor applies to 3-5 ton models only.
The standard motor for 6-10 ton models is belt drive.
RT-PRC005-EN
50
Download from Www.Somanuals.com. All Manuals Search And Download.
(High
Efficiency)
Electrical
Data
Table ED-2 — UnitWiring — High Efficiency
Optional
Standard Indoor Fan Motor
Minimum Maximum Fuse
Circuit Size Or Maximum
Ampacity Circuit Breaker1
Oversize Indoor Fan Motor
Belt Drive Indoor Fan Motor2
Minimum Maximum Fuse
Unit
Operating
Voltage Range
187-253
Minimum Maximum Fuse
Circuit Size Or Maximum
Ampacity Circuit Breaker1
Unit
Circuit
Size or Maximum
Tons
3
Model No.
THC036A1
THC036A3
THC036A4
THC036AW
Ampacity Circuit Breaker1
23.9
16.7
8.3
40
25
15
15
26.3
19.1
9.5
40
25
15
15
N/A
19.4
9.7
N/A
25
15
187-253
414-506
517-633
7.0
7.6
7.6
15
THC048A1
THC048A3
THC048A4
THC048AW
187-253
187-253
414-506
517-633
29.4
21.2
11.0
8.3
45
30
15
15
31.5
23.3
12.6
9.1
50
35
15
15
N/A
22.6
11.8
8.5
N/A
35
15
4
15
THC060A1
THC060A3
THC060A4
THC060AW
187-253
187-253
414-506
517-633
39.5
30.0
14.7
11.8
60
45
20
15
41.2
31.7
15.0
12.4
60
45
20
15
N/A
28.8
14.3
11.4
N/A
45
20
5
15
THC072A3
THC072A4
THC072AW
THC092A3
THC092A4
THC092AW
THC102A3
THC102A4
THC102AW
187-253
414-506
517-633
187-253
414-506
517-633
187-253
414-506
517-633
34.8
17.5
13.5
38.1
19.4
14.8
42.3
21.4
16.6
50
25
20
50
25
15
50
25
20
36.1
18.1
14.3
41.2
20.9
16.0
45.4
22.9
17.8
50
25
20
50
25
20
60
30
20
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
6
7½
8½
THC120A3
THC120A4
THC120AW
187-253
414-506
517-633
48.6
25.3
19.9
60
30
25
52.6
27.3
21.6
60
35
25
—
—
—
—
—
—
10
NOTES:
1. HACR breaker per NEC.
RT-PRC005-EN
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
(Standard
Efficiency)
Table ED-3 — UnitWiringWith Electric Heat (Single Point Connection) —208/230Volts — Standard Efficiency
Standard Indoor Motor
Oversize Indoor Motor
Max Fuse Size Or
To Use
With
Heater
Model No.
Heater
Control
Stages
Max Fuse Size Or
Tons
kW Rating1
MCA
Max Circuit Breaker2
MCA
Max Circuit Breaker2
208/230 Volts Single Phase
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
3.8/5.0
7.5/10.0
10.4/13.8
1
2
2
25.5/28.9
48.0/55.0
65.1/74.8
40/40
50/60
70/80
28.5/31.9
51.0/58.0
68.1/77.8
40/40
60/60
70/80
3
4
TSC036A1
TSC048A1
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
BAYHTRR118A
3.8/5.0
7.5/10.0
10.4/13.8
13.2/17.6
1
2
2
2
34.0/34.0
49.6/56.6
66.8/76.4
84.0/96.1
50/50
50/60
70/80
90/100
36.1/36.1
52.3/59.3
69.4/79.0
86.6/98.8
50/50
60/60
70/80
90/100
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
BAYHTRR118A
3.8/5.0
7.5/10.0
10.4/13.8
13.2/17.6
1
2
2
2
47.3/47.3
52.9/59.9
70.0/79.6
87.3/99.4
60/60
60/60
80/80
90/100
49.0/49.0
55.0/62.0
72.1/81.8
89.4/101.54
60/60
60/70
80/90
90/110
5
TSC060A1
208/230 Volts Three Phase
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
4.5/6.0
9.0/12.0
13.1/17.4
1
2
2
18.5/20.9
34.1/39.0
48.3/55.3
25/25
35/40
50/60
21.5/23.9
37.1/42.0
51.3/58.3
30/30
40/45
60/60
3
4
TSC036A3
TSC048A3
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
4.5/6.0
9.0/12.0
13.1/17.4
1
2
2
23.9/23.9
35.8/40.6
49.9/56.9
35/35
40/45
50/60
26.0/26.0
38.4/43.3
52.5/59.5
40/40
40/45
60/60
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
BAYHTRR323A
4.5/6.0
9.0/12.0
13.1/17.4
17.3/23.0
1
2
2
2
31.5/31.5
39.0/43.9
53.1/60.1
67.8/76.9
50/50
50/50
60/70
70/80
33.2/33.2
41.1/46.0
55.3/62.3
69.9/79.0
50/50
50/50
60/70
70/80
5
6
TSC060A3
TSC072A3
TSC090A3
TSC092A3
TSC102A3
TSC120A3
BAYHTRS309A
6.8/9.0
1
32.7/33.4
50/50
34.0/35.0
50/50
BAYHTRS318A
BAYHTRS327A
BAYHTRS336A
13.5/18.0
20.3/27.0
27.0/36.0
1
2
2
53.1/60.4
76.6/87.5
100.1/114.5
60/70
80/90
110/125
54.8/62.0
78.3/89.1
101.8/116.1
60/70
80/90
110/125
BAYHTRS309A
BAYHTRS318A
BAYHTRS327A
BAYHTRS336A
6.8/9.0
1
1
2
2
42.7/42.7
54.8/62.0
78.3/89.1
101.8/116.1
60/60
60/70
80/90
45.8/45.8
58.6/65.9
82.1/93.0
105.6/120.0
60/60
60/70
90/100
110/125
13.5/18.0
20.3/27.0
27.0/36.0
110/125
7½
8½
BAYHTRS309A
BAYHTRS318A
BAYHTRS327A
BAYHTRS336A
6.8/9.0
1
1
2
2
38.9/38.9
54.8/62.0
78.3/89.1
101.8/116.1
50/50
60/70
80/90
42.0/42.0
58.6/65.9
82.1/93.0
105.6/120.0
50/50
60/70
90/100
110/125
13.5/18.0
20.3/27.0
27.0/36.0
110/125
BAYHTRT309A
BAYHTRT318A
BAYHTRT327A
BAYHTRT336A
6.8/9.0
1
1
2
2
45.1/45.1
54.8/62.0
78.3/89.1
101.8/116.1
60/60
60/70
80/90
48.2/48.2
58.6/65.9
82.193.0
60/60
60/70
90/100
110/125
13.5/18.0
20.3/27.0
27.0/36.0
110/125
105.6/120.0
BAYHTRT318A
BAYHTRT327A
BAYHTRT336A
BAYHTRT354A
13.5/18.0
20.3/27.0
27.0/36.0
40.6/54.0
1
2
2
2
58.6/65.9
82.1/93.0
105.8/120.0
152.5/141.7
60/70
90/100
110/125
175/150
63.6/70.9
87.1/98.0
110.6/125.0
157.5/146.7
70/80
90/100
125/125
175/150
10
NOTES:
1. Heater kW ratings are at 208/240 for 208/230V unit
2. HACR type circuit breaker per NEC.
RT-PRC005-EN
52
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
(Standard
Efficiency)
Table ED-4 — UnitWiringWith Electric Heat (Single Point Connection) — Standard Efficiency
Standard Indoor Motor
Oversize Indoor Motor
Max Fuse Size Or
To Use
With
Heater
Model No.
Heater
Control
Stages
Max Fuse Size Or
Tons
kW Rating1
MCA
Max Circuit Breaker2
MCA
Max Circuit Breaker2
380 Volts Three Phase
BAYHTRR412A
BAYHTRR418A
BAYHTRR423A
7.5
10.9
14.4
2
2
2
19.6
26.1
32.8
30
30
35
—
—
—
—
—
—
5
6
TSC060AK
TSC072AK
BAYHTRS418A
BAYHTRS427A
BAYHTRS436A
11.3
16.9
22.6
1
2
2
27.6
38.3
49.0
35
40
50
—
—
—
—
—
—
BAYHTRS418A
BAYHTRS427A
BAYHTRS436A
11.3
16.9
22.6
1
2
2
28.4
38.3
49.0
40
40
50
29.9
40.1
50.9
45
45
60
7½
8½
TSC090AK
TSC102AK
BAYHTRT427A
BAYHTRT436A
16.9
22.6
2
2
38.8
49.0
40
50
40.1
50.9
45
60
BAYHTRT427A
BAYHTRT436A
BAYHTRT454A
16.9
22.6
33.8
2
2
2
40.1
50.9
72.3
45
60
80
43.6
54.4
75.8
45
60
80
10
TSC120AK
460 Volts Three Phase
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
6.0
12.0
17.4
1
2
2
10.4
19.4
27.5
15
20
30
11.9
20.9
29.0
15
25
30
3
4
TSC036A4
TSC048A4
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
6.0
12.0
17.4
1
2
2
12.8
20.1
28.3
20
25
30
14.4
22.1
30.3
20
25
35
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
BAYHTRR423A
6.0
1
2
2
2
16.0
21.6
29.8
38.3
25
25
30
40
16.3
22.0
30.1
38.6
25
25
35
40
12.0
17.4
23.0
5
6
TSC060A4
TSC072A4
BAYHTRS409A
BAYHTRS418A
BAYHTRS427A
BAYHTRS436A
9.0
1
1
2
2
17.6
30.3
43.8
57.3
25
35
45
60
18.2
31.0
44.5
58.0
25
35
45
60
18.0
27.0
36.0
BAYHTRS409A
BAYHTRS418A
BAYHTRS427A
BAYHTRS436A
9.0
1
1
2
2
22.6
31.0
44.5
58.0
35
35
45
60
24.1
32.9
46.4
59.9
35
35
50
60
TSC090A4
18.0
27.0
36.0
7½
8½
BAYHTRS409A
BAYHTRS418A
BAYHTRS427A
BAYHTRS436A
9.0
1
1
2
2
20.5
31.0
44.5
58.0
25
35
45
60
22.0
32.9
46.4
59.9
25
35
50
60
TSC092A4
TSC102A4
TSC120A4
18.0
27.0
36.0
BAYHTRT409A
BAYHTRT418A
BAYHTRT427A
BAYHTRT436A
9.0
1
1
2
2
24.0
31.0
44.5
58.0
30
35
45
60
25.5
32.9
46.4
59.9
35
35
50
60
18.0
27.0
36.0
BAYHTRT418A
BAYHTRT427A
BAYHTRT436A
BAYHTRT454A
18.0
27.0
36.0
54.0
1
2
2
2
32.9
46.4
59.9
70.8
35
50
60
80
35.4
48.9
62.4
73.3
40
50
70
80
10
NOTES:
1. Heater kW ratings are at 208/240 for 208/230V, unit
2. HACR type circuit breaker per NEC.
RT-PRC005-EN
53
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
(Standard
Efficiency)
Table ED-5 — UnitWiringWith Electric Heat (Single Point Connection) — 575Volts — Standard Efficiency
Standard Indoor Motor
Oversize Indoor Motor
To Use
With
Heater
Model No.
Heater
kW Rating1
Control
Stages
Max Fuse Size Or
Max Circuit Breaker2
Max Fuse Size Or
Max Circuit Breaker2
Tons
MCA
MCA
575 Volts Three Phase
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
6.0
12.0
17.4
1
2
2
8.6
15.8
22.3
15
20
25
9.3
16.6
23.1
15
20
25
3
4
TSC036AW
TSC048AW
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
6.0
12.0
17.4
1
2
2
9.8
16.3
22.8
15
20
25
10.6
17.3
23.8
15
20
25
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
BAYHTRRW23A
6.0
1
2
2
2
12.2
17.1
23.6
30.3
15
20
25
35
12.8
17.8
24.3
31.0
20
20
25
35
12.0
17.4
23.0
5
6
TSC060AW
TSC072AW
BAYHTRSW09A
BAYHTRSW18A
BAYHTRSW27A
BAYHTRSW36A
9.0
1
1
2
2
13.0
23.8
34.6
45.4
20
25
35
50
14.0
24.8
35.6
46.4
20
25
40
50
18.0
27.0
36.0
BAYHTRSW09A
BAYHTRSW18A
BAYHTRSW27A
BAYHTRSW36A
9.0
1
1
2
2
17.6
24.8
35.6
46.4
25
25
40
50
18.8
26.3
37.1
47.9
25
30
40
50
TSC090AW
TSC092AW
18.0
27.0
36.0
7½
8½
BAYHTRSW09A
BAYHTRSW18A
BAYHTRSW27A
BAYHTRSW36A
9.0
1
1
2
2
15.5
24.8
35.6
46.4
20
25
40
50
16.7
26.3
37.1
47.9
20
30
40
50
18.0
27.0
36.0
BAYHTRTW18A
BAYHTRTW27A
BAYHTRTW36A
18.0
27.0
36.0
1
2
2
24.8
35.6
46.4
25
40
50
26.3
37.1
47.9
30
40
50
TSC102AW
TSC120AW
BAYHTRTW18A
BAYHTRTW27A
BAYHTRTW36A
BAYHTRTW54A
18.0
27.0
36.0
54.0
1
2
2
2
26.3
37.1
47.9
56.6
30
40
50
60
28.4
39.3
50.0
58.8
30
40
50
60
10
NOTES:
1. Heater kW ratings are at 208/240 for 208/230V unit
2. HACR type circuit breaker per NEC.
RT-PRC005-EN
54
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
(Standard
Efficiency)
Table ED-5 — UnitWiringWith Electric Heat (Single Point Connection) — Optional Belt Drive — Standard Efficiency
Optional Belt Drive Indoor Motor
To Use
With
Heater
Model No.
Heater
kW Rating1
Control
Stages
Max Fuse Size Orr
Max Circuit Breaker2
Tons
MCA
208/230 Volts Single Phase
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3
4
TSC036A1
TSC048A1
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
BAYHTRR118A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
BAYHTRR118A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5
TSC060A1
208/230 Volts Three Phase
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
4.5/6.0
9.0/12.0
13.1/17.4
1
2
2
21.9/24.3
37.5/42.4
51.6/58.6
30/30
40/45
60/60
3
4
TSC036A3
TSC048A3
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
4.5/6.0
9.0/12.0
13.1/17.4
1
2
2
25.3/25.3
37.5/42.4
51.6/58.6
35/35
40/45
60/60
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
BAYHTRR323A
4.5/6.0
9.0/12.0
13.1/17.4
17.3/23.0
1
2
2
2
30.3/30.3
37.5/42.4
51.6/58.6
66.3/75.4
45/45
45/45
60/60
70/80
5
TSC060A3
460 Volts Three Phase
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
6.0
12.0
17.4
1
2
2
12.1
21.1
29.3
15
25
30
3
TSC036A4
TSC048A4
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
6.0
12.0
17.4
1
2
2
13.6
21.1
29.3
20
25
30
4
5
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
BAYHTRR423A
6.0
1
2
2
2
15.6
21.1
29.3
37.8
25
25
30
40
12.0
17.4
23.0
TSC060A4
575 Volts Three Phase
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
6.0
12.0
17.4
1
2
2
9.3
16.6
23.1
15
20
25
3
4
TSC036AW
TSC048AW
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
6.0
12.0
17.4
1
2
2
10.0
16.6
23.1
15
20
25
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
BAYHTRRW23A
6.0
1
2
2
2
11.8
16.6
23.1
29.8
15
20
25
30
12.0
17.4
23.0
5
TSC060AW
NOTES:
1. Heater kW ratings are at 208/240 for 208/230V unit
2. HACR type circuit breaker per NEC.
RT-PRC005-EN
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
(High Efficiency)
Table ED-7 — UnitWiringWith Electric Heat (Single Point Connection) — 208/230Volts — High Efficiency
Standard Indoor Motor
Oversize Indoor Motor
To Use
With
Heater
Model No.
Heater
kW Rating1
Control
Stages
Max Fuse Size Or
Max Circuit Breaker2
Max Fuse Size Or
Max Circuit Breaker2
Tons
MCA
MCA
208/230 Volts Single Phase
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
3.8/5.0
7.5/10.0
10.4/13.8
1
2
2
25.5/28.9
48.0/55.0
65.1/74.8
40/40
50/60
70/80
28.5/31.9
51.0/58.0
68.1/77.8
40/40
60/60
70/80
3
4
THC036A1
THC048A1
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
BAYHTRR118A
3.8/5.0
7.5/10.0
10.4/13.8
13.2/17.6
1
2
2
2
29.4/30.5
49.6/56.6
66.8/76.4
84.0/96.1
45/45
50/60
70/80
90/100
31.5/33.1
52.3/59.3
69.4/79.0
86.6/98.8
50/50
60/60
70/80
90/100
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
BAYHTRR118A
3.8/5.0
7.5/10.0
10.4/13.8
13.2/17.6
1
2
2
2
39.5/39.5
52.9/59.9
70.0/79.6
87.3/99.4
60/60
60/60
80/80
90/100
41.2/41.2
55.0/62.0
72.1/81.8
89.4/101.5
60/60
60/70
80/90
90/100
5
THC060A1
208/230 Volts Three Phase
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
4.5/6.0
9.0/12.0
13.1/17.4
1
2
2
18.5/20.9
34.1/39.0
48.3/55.3
25/25
35/40
50/60
21.5/23.9
37.1/42.0
51.3/58.3
25/25
40/45
60/60
3
4
THC036A3
THC048A3
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
4.5/6.0
9.0/12.0
13.1/17.4
1
2
2
21.2/22.5
35.8/40.6
49.9/56.9
30/30
40/45
50/60
23.3/25.1
38.4/43.3
52.5/59.5
35/35
40/45
60/60
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
BAYHTRR323A
4.5/6.0
9.0/12.0
13.1/17.4
17.3/23.0
1
2
2
2
30.0/30.0
39.0/43.9
53.1/60.1
67.8/76.9
45/45
45/45
60/70
70/80
31.7/31.7
41.1/46.0
55.3/62.3
69.9/79.0
45/45
45/50
60/70
70/80
5
6
THC060A3
THC072A3
BAYHTRS309A
BAYHTRS318A
BAYHTRS327A
BAYHTRS336A
6.8/9.0
1
1
2
2
34.8/34.8
53.1/60.4
76.6/87.5
100.1/114.5
50/50
60/70
80/90
35.7/35.7
54.8/62.0
78.3/89.1
101.8/116.1
50/50
60/70
80/90
13.5/18.0
20.3/27.0
27.0/36.0
110/125
110/125
BAYHTRT309A
BAYHTRT318A
BAYHTRT327A
BAYHTRT336A
6.8/9.0
1
1
2
2
38.1/38.1
54.8/62.0
78.3/89.1
101.8/116.1
50/50
60/70
80/90
44.2/44.2
58.6/65.9
82.1/93.0
105.6/120.0
50/50
60/70
90/100
110/125
7½
8½
THC092A3
THC102A3
THC120A3
13.5/18.0
20.3/27.0
27.0/36.0
110/125
BAYHTRT309A
BAYHTRT318A
BAYHTRT327A
BAYHTRT336A
6.8/9.0
1
1
2
2
42.3/42.3
54.8/62.0
78.3/89.1
101.8/116.1
50/50
60/70
80/90
44.2/44.2
58.6/65.9
82.1/93.0
105.6/120.0
50/50
60/70
90/100
110/125
13.5/18.0
20.3/27.0
27.0/36.0
110/125
BAYHTRT318A
BAYHTRT327A
BAYHTRT336A
BAYHTRT354A
13.5/18.0
20.3/27.0
27.0/36.0
40.6/54.0
1
2
2
2
58.6/65.9
82.1/93.0
105.6/120.0
152.5/141.7
60/70
90/100
110/125
175/150
63.6/70.9
87.1/98.0
110.6/125.0
157.5/146.7
70/80
90/100
125/125
175/150
10
NOTES:
1. Heater kW ratings are at 208/240 for 208/230V unit
2. HACR type circuit breaker per NEC.
RT-PRC005-EN
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
(High Efficiency)
Table ED-8 — UnitWiringWith Electric Heat (Single Point Connection) — 460Volts — High Efficiency
Standard Indoor Motor
Oversize Indoor Motor
Max Fuse Size Or
To Use
With
Heater
Heater
kW Rating1
Control
Stages
Max Fuse Size Or
Tons
Model No.
MCA
Max Circuit Breaker2
MCA
Max Circuit Breaker2
460 Volts Three Phase
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
6.0
12.0
17.4
1
2
2
10.4
19.4
27.5
15
20
30
11.9
20.9
29.9
15
25
30
3
4
5
THC036A4
THC048A4
THC060A4
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
6.0
12.0
17.4
1
2
2
11.1
20.1
28.3
15
25
30
13.1
22.1
30.3
15
25
35
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
BAYHTRR423A
6.0
1
2
2
2
14.7
21.6
29.8
38.3
20
25
30
40
15.0
22.0
30.1
38.6
20
25
35
40
12.0
17.4
23.0
BAYHTRS409A
BAYHTRS418A
BAYHTRS427A
BAYHTRS436A
9.0
1
1
2
2
17.5
30.3
43.8
57.3
25
35
45
60
18.1
31.0
44.5
58.0
25
35
45
60
6
THC072A4
THC092A4
THC102A4
THC120A4
18.0
27.0
36.0
BAYHTRT409A
BAYHTRT418A
BAYHTRT427A
BAYHTRT436A
9.0
1
1
2
2
19.4
31.0
44.5
58.0
25
35
45
60
20.9
32.9
46.4
59.9
25
35
50
60
7½
8½
18.0
27.0
36.0
BAYHTRT409A
BAYHTRT418A
BAYHTRT427A
BAYHTRT436A
9.0
1
1
2
2
21.4
31.0
44.5
58.0
25
35
45
60
22.9
32.9
46.4
59.9
30
35
50
60
18.0
27.0
36.0
BAYHTRT418A
BAYHTRT427A
BAYHTRT436A
BAYHTRT454A
18.0
27.0
36.0
54.0
1
2
2
2
32.9
46.4
59.9
70.8
35
50
60
80
35.4
48.9
62.4
73.3
40
50
70
80
10
NOTES:
1. Heater kW ratings are at 208/240 for 208/230V unit
2. HACR type circuit breaker per NEC.
RT-PRC005-EN
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
(High Efficiency)
Table ED-9 — UnitWiringWith Electric Heat (Single Point Connection) — 575Volts — High Efficiency
Standard Indoor Motor
Oversize Indoor Motor
To Use
With
Heater
Model No.
Heater
kW Rating1
Control
Stages
Max Fuse Size Or
Max Circuit Breaker2
Max Fuse Size Or
Max Circuit Breaker2
Tons
MCA
MCA
575 Volts Three Phase
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
6.0
12.0
17.4
1
2
2
8.6
15.8
22.3
15
20
25
9.3
16.6
23.1
15
20
25
3
4
THC036AW
THC048AW
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
6.0
12.0
17.4
1
2
2
9.1
16.3
22.8
15
20
25
10.1
17.3
23.8
15
20
25
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
BAYHTRRW23A
6.0
1
2
2
2
11.8
17.1
23.6
30.3
15
20
25
35
12.4
17.8
24.3
31.0
15
20
25
35
12.0
17.4
23.0
5
6
THC060AW
THC072AW
BAYHTRSW09A
9.0
1
13.5
20
14.3
20
BAYHTRSW18A
BAYHTRSW27A
BAYHTRSW36A
18.0
27.0
36.0
1
2
2
23.8
34.6
45.4
25
35
50
24.8
35.6
46.4
25
40
50
BAYHTRTW18A
BAYHTRTW27A
BAYHTRTW36A
18.0
27.0
36.0
1
2
2
24.8
35.6
46.4
25
40
50
26.3
37.1
47.9
30
40
50
7½
8½
10
THC092AW
THC102AW
THC120AW
BAYHTRTW18A
BAYHTRTW27A
BAYHTRTW36A
18.0
27.0
36.0
1
2
2
24.8
35.6
46.4
25
40
50
26.3
37.1
47.9
30
40
50
BAYHTRTW18A
BAYHTRTW27A
BAYHTRTW36A
BAYHTRTW54A
18.0
27.0
36.0
54.0
1
2
2
2
26.3
37.1
47.9
56.6
30
40
50
60
28.4
39.3
50.0
58.8
30
40
50
60
NOTES:
1. Heater kW ratings are at 208/240 for 208/230V unit
2. HACR type circuit breaker per NEC.
RT-PRC005-EN
58
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
(High Efficiency)
Table ED-10 — UnitWiringWith Electric Heat (Single Point Connection) — Optional Belt Drive — High
Efficiency
Belt Drive Indoor Motor
To Use
With
Heater
Model No.
Heater
kW Rating1
Control
Stages
Max Fuse Size Or
Max Circuit Breaker2
Tons
MCA
208/230 Volts Single Phase
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
3
4
THC036A1
THC048A1
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
BAYHTRR118A
N/A
N/A
1N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
BAYHTRR105A
BAYHTRR110A
BAYHTRR114A
BAYHTRR118A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
5
THC060A1
208/230 Volts Three Phase
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
4.5/6.0
9.0/12.0
13.1/17.4
1
2
2
21.9/24.3
37.5/42.4
51.6/58.6
25/25
40/45
60/60
3
4
THC036A3
THC048A3
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
4.5/6.0
9.0/12.0
13.1/17.4
1
2
2
22.6/24.3
37.5/42.4
51.6/58.6
35/35
40/45
60/60
BAYHTRR306A
BAYHTRR312A
BAYHTRR318A
BAYHTRR323A
4.5/6.0
9.0/12.0
13.1/17.4
17.3/23.0
1
2
2
2
28.8/28.8
37.5/42.4
51.6/58.6
66.3/75.4
45/45
45/45
60/60
70/80
5
THC060A3
460 Volts Three Phase
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
6.0
12.0
17.4
1
2
2
12.1
21.1
29.3
15
25
30
3
4
5
THC036A4
THC048A4
THC060A4
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
6.0
12.0
17.4
1
2
2
12.1
21.1
29.3
15
25
30
BAYHTRR406A
BAYHTRR412A
BAYHTRR418A
BAYHTRR423A
6.0
1
2
2
2
14.3
21.1
29.3
37.8
20
25
30
40
12.0
17.4
23.0
575 Volts Three Phase
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
6.0
12.0
17.4
1
2
2
9.3
16,6
23.1
15
20
25
3
4
THC036AW
THC048AW
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
6.0
12.0
17.4
1
2
2
9.3
16.6
23.1
15
20
25
BAYHTRRW06A
BAYHTRRW12A
BAYHTRRW18A
BAYHTRRW23A
6.0
1
2
2
2
11.4
16.6
23.1
29.8
15
20
25
30
12.0
17.4
23.0
5
THC060AW
NOTES:
1. Heater kW ratings are at 208/240 for 208/230V unit
2. HACR type circuit breaker per NEC.
RT-PRC005-EN
59
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Table ED-11 — Electrical Characteristics — Evaporator Fan Motor — 60 Cycle — Standard and Oversized
Standard Evaporator Fan Motor
Oversized Evaporator Fan Motor
Amps
FLA
Amps
Unit
Tons Model No.
T#C036A1
No.
Volts
Phase
HP
FLA
LRA
No.
Volts
Phase
HP
LRA
1
1
1
1
208-230
208-230
460
1
1
1
1
.33
.33
.33
.33
2.30
2.30
1.10
1.10
3.90
3.90
2.00
1.80
1
1
1
1
208-230
208-230
460
1
1
1
1
.50
.50
.50
.50
4.70
4.70
2.30
1.70
9.80
9.80
5.20
3.60
3
T#C036A3
T#C036A4
T#C036AW
575
460
T#C048A1
T#C048A3
T#C048A4
T#C048AW
T#C060A1
T#C060A3
T#C060A4
T#C060AW
TSC060AK
T#C072A3
T#C072A4
T#C072AW
TSC072AK
1
1
1
1
1
1
1
1
1
1
1
1
1
208-230
208-230
460
1
1
1
1
1
1
1
1
1
3
3
3
3
.60
.60
.60
.60
.90
.90
.90
.90
1.00
1.00
1.00
1.00
2.0
3.60
3.60
1.70
1.50
6.20
6.20
2.90
2.10
4.3
5.00
2.50
1.70
4.9
6.60
6.60
2.80
2.40
14.0
14.0
6.60
4.90
8.3
32.20
16.10
13.20
35.0
1
1
1
1
1
1
1
1
—
1
1
208-230
208-230
460
1
1
1
1
1
1
1
1
—
3
3
.80
..80
.80
.80
1.00
1.00
1.00
1.00
—
2.00
2.00
2.00
—
5.70
5.70
3.30
2.30
7.90
7.90
3.2
2.4
—
6.30
3.10
2.50
—
13.60
13.60
7.20
4
5
6
575
575
5.80
208-230
208-230
460
575
380
208-230
460
575
208-230
208-230
460
575
—
208-230
460
575
16.40
16.40
8.20
5.00
—
48.00
24.00
18.20
—
1
—
3
—
380
—
T#C090A3
T#C090A4
T#C090AW
TSC090AK
T#C092A3
T#C092A4
T#C092AW
T#C102A3
T#C102A4
T#C102AW
TSC102AK
T#C120A3
T#C120A4
T#C120AW
TSC120AK
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
208-230
460
575
380
208-230
460
575
208-230
460
575
380
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
2.00
2.00
2.00
2.0
2.00
2.00
2.00
2.00
2.00
2.00
2.0
3.00
3.00
3.00
3.0
6.30
3.10
2.50
4.9
6.30
3.10
2.50
6.30
3.10
2.50
4.9
9.40
4.60
3.70
6.4
48.00
24.00
18.20
35.0
48.00
24.00
18.20
48.00
24.00
18.20
35.0
83.00
42.00
31.00
51.1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
208-230
460
575
380
208-230
460
575
208-230
460
575
380
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3.00
3.00
3.00
3.0
3.00
3.00
3.00
3.00
3.00
3.00
3.0
5.00
5.00
5.00
5.0
9.40
4.60
3.70
6.4
9.40
4.60
3.70
9.40
4.60
3.70
6.4
13.40
6.60
5.40
10.8
83.00
42.00
31.00
51.1
83.00
42.00
31.00
83.00
42.00
31.00
51.1
112.00
56.00
44.0
7½
8½
10
208-230
460
575
208-230
460
575
380
380
66.5
Table ED-12 — Electrical Characteristics — Evaporator Fan Motor — 60 Cycle — Optional Belt Drive
Amps
Unit
Tons
3
Model No.
No.
Volts
Phase
HP
FLA
LRA
T#C036A3
T#C036A4
T#C036AW
1
1
1
208-230
460
575
3
3
3
1.00
1.00
1.00
5.00
2.50
1.70
32.20
16.10
13.20
T#C048A3
T#C048A4
T#C048AW
1
1
1
208-230
460
575
3
3
3
1.00
1.00
1.00
5.00
2.50
1.70
32.20
16.10
13.20
4
5
T#C060A3
T#C060A4
T#C060AW
1
1
1
208-230
460
575
3
3
3
1.00
1.00
1.00
5.00
2.50
1.70
32.20
16.10
13.20
RT-PRC005-EN
60
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Table ED-13— Electrical Characteristics — Compressor MotorAnd Condenser Motor — 60 Cycle — Standard Efficiency
Compressor Motors
Condenser Fan Motors
Amps
FLA
1
Amps
Unit
Tons
Model No.
No.
Volts
Phase
HP2
RPM
RLA
LRA
No.
Phase
HP
LRA
TSC036A1
TSC036A3
TSC036A4
TSC036AW
1
1
1
1
208-230
208-230
460
1
3
3
3
3.1
3.1
3.1
3.1
3450
3450
3450
3450
17.2
11.3
6.0
104.0
74.0
37.6
1
1
1
1
1
1
1
1
.20
.20
.20
.20
1.5
1.5
.6
2.5
2.5
1.3
1.2
3
575
4.9
30.4
.5
TSC048A1
TSC048A3
TSC048A4
TSC048AW
TSC060A1
TSC060A3
TSC060A4
TSC060AW
TSC060AK
1
1
1
1
1
1
1
1
1
208-230
208-230
460
1
3
3
3
1
3
3
3
3
3.9
3.9
3.9
3.9
5.1
5.1
5.1
5.1
5.1
3450
3450
3450
3450
3450
3450
3450
3450
3450
22.7
14.6
7.9
131.0
91.0
46.0
37.0
144.0
128.0
63.0
49.0
64
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
.33
.33
..33
.33
.33
.33
.33
.33
.40
2.0
2.0
1.2
.7
2.0
2.0
1.2
.7
6.6
6.6
2.5
1.5
6.6
6.6
2.5
1.5
4.3
4
5
575
6.1
208-230
208-230
460
575
380
31.3
18.6
9.5
7.5
11.4
1.1
TSC072A3
TSC072A4
TSC072AW
TSC072AK
1
1
1
1
208-230
460
575
3
3
3
3
6
6
6
6
3450
3450
3450
3450
18.6
10.1
7.7
156
75
54
1
1
1
1
1
1
1
1
.70
.70
.70
.75
3.85
2.50
1.54
2.5
9.30
5.80
3.60
7.7
6
380
12.2
70
TSC090A3
TSC090A4
TSC090AW
TSC090AK
TSC092A3
TSC092A4
TSC092AW
TSC102A3
TSC102A4
TSC102AW
TSC102AK
1
1
1
1
2
2
2
2
2
2
1
208-230
460
575
380
208-230
460
575
208-230
460
575
3
3
3
3
3
3
3
3
3
3
3
7.5
7.5
7.5
3450
3450
3450
3450
3450 14.7/10.3
3450
3450
26.0
13.6
10.9
16.4
172
90
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
.70
.70
.70
.75
.70
.70
.70
.75
.75
.75
.75
3.85
2.50
1.54
2.5
3.85
2.50
1.54
4.0
2.8
2.4
2.5
9.30
5.80
3.60
7.7
9.30
5.80
3.60
9.4
6.8
6.2
7.7
62.3
92.5
91/77
50/39
37/31
128/77
63/39
49/31
64/39
7.5
7½
8½
4/2.8
4/2.8
4/2.8
7.6/5.4
5.8/4.2
5.1/2.8 3450 18.6/10.3
5.1/2.8 3450 10.0/5.4
5.1/2.8 3450
8.2/4.2
380
5.1/2.8 3450 12.1/6.6
TSC120A3
TSC120A4
TSC120AW
TSC120AK
2
2
2
1
208-230
460
575
3
3
3
3
5.1/3.9 3450 18.6/14.7
128/91
63/46
49/37
64/54
1
1
1
1
1
1
1
1
.75
.75
.75
.75
4.0
2.8
2.4
2.5
9.4
6.8
6.2
7.7
10
5.1/3.9 3450
5.1/3.9 3450
5.1/3.9 3450
9.5/7.4
7.8/.58
11.5/9.0
380
NOTES:
1. Amp draw for each motor; multiply value by number of motors to determine total amps.
2. HP for each compressor.
RT-PRC005-EN
61
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Table ED-14 — Electrical Characteristics — Compressor MotorAnd Condenser Motor — 60 Cycle — High Efficiency
Compressor Motors
Condenser Fan Motors
Amps1
Unit
Amps1
RLA LRA
88.0
Tons
Model No.
No.
Volts
Phase
HP2
RPM
No.
Phase
HP
FLA
LRA
THC036A1
THC036A3
THC036A4
THC036AW
1
1
1
1
208-230
208-230
460
1
3
3
3
2.8
2.8
2.8
2.8
3450
3450
3450
3450
16.1
10.3
5.3
1
1
1
1
1
1
1
1
.20
.20
.20
.20
1.5
1.5
0.6
0.5
2.5
2.5
1.3
1.2
77.0
39.0
31.0
3
575
4.3
THC048A1
THC048A3
THC048A4
THC048AW
1
1
1
1
208-230
208-230
460
1
3
3
3
3.5
3.5
3.5
3.5
3450
3450
3450
3450
19.0
12.5
6.5
109.0
88.0
44.0
34.0
1
1
1
1
1
1
1
1
.33
.33
.33
.33
2.0
2.0
1.2
0.7
6.6
6.6
2.5
1.5
4
575
4.9
THC060A1
THC060A3
THC060A4
THC060AW
THC072A3
THC072A4
THC072AW
THC092A3
THC092A4
THC092AW
1
1
1
1
1
1
1
2
2
2
208-230
208-230
460
575
208-230
460
575
208-230
460
575
208-230
460
1
3
3
3
3
3
3
3
3
3
4.5
4.5
4.5
4.5
5.7
5.7
5.7
3450
3450
3450
3450
3450
3450
3450
25.0
17.4
7.8
6.2
20.7
169.0
124.0
59.6
49.4
156
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
.33
.33
.33
.33
.70
.70
.70
.70
.70
.70
2.0
2.0
1.2
6.6
6.6
2.5
5
0.9
1.5
3.85
2.50
1.54
3.85
2.50
1.54
4.0
2.8
2.4
9.30
5.80
3.60
9.30
5.80
3.60
9.4
6.8
6.2
6
10
8.2
75
54
3.5/3.3 3450
3.5/3.3 3450
3.5/3.3 3450
3.9/3.5 3450
3.9/3.5 3450
3.9/3.5 3450
12.4/12.4
6.4/5.8
4.8/4.8
14.7/12.4
7.1/6.4
88/88
44/44
34/34
91/88
50/44
37/34
7½
8½
THC102A3
THC102A4
THC102AW
2
2
2
3
3
3
1
1
1
1
1
1
.75
.75
.75
575
5.4/4.8
THC120A3
THC120A4
THC120AW
2
2
2
208-230
460
575
3
3
3
4.8/3.5 3450
4.8/3.5 3450
4.8/3.5 3450
17.3/12.4 124/88
1
1
1
1
1
1
.75
.75
.75
4.0
2.8
2.4
9.4
6.8
6.2
10
9.0/6.4
7.1/4.8
59.6/44
49.4/34
NOTES:
1. Amp draw for each motor; multiply value by number of motors to determine total amps.
2. HP for each compressor.
Table ED-15— Electrical Characteristics — Power Exhaust
Accessory
Tons
6-10
6-10
6-10
Note:
Model No.
Volts
208-230
460
Phase
HP
RPM1
FLA
5.7
3.3
2.3
LRA
16.3
6.8
BAYPWRX026
BAYPWRX027
BAYPWRX028
1
1
1
0.87
0.87
0.87
1075
1075
1075
575
5.4
1. Two speed.
RT-PRC005-EN
62
Download from Www.Somanuals.com. All Manuals Search And Download.
Jobsite
Connections
Zone Sensors —Typical Number OfWires
DISCONNECT
SWITCH
(BY OTHERS)
A— Manual Changeover...................................... 4
Manual/Auto Changeover ............................. 5
Manual/Auto Changeover with
Status Indication LED’s .......................... 10
Programmable Night Setback with
ZONE SENSOR
OR THERMOSTAT
Status Indication LED’s ............................ 7
ROOFTOP
UNIT
Thermostats — Typical Number of Wires
A — 3 wires, 24-volts, Cooling Only
4 wires, 24-volts, with Electric Heat
B— 3 Power Wires + 1 Ground Wire (three phase)
2 Power Wires + 1 Ground Wire (single phase)
For specific wiring information, see the installation instructions.
All wiring except power wires is low voltage.
All customer supplied wiring to be copper and must conform to applicable electrical codes (such as NEC or CEC) and local electrical codes. Wiring shown dotted is to be
furnished and installed by the customer.
RT-PRC005-EN
63
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional
Data
(3-5Tons)
All dimensions are in inches/millimeters.
3 - 5Tons Standard Efficiency
3 and 4Tons High Efficiency
5Tons High Efficiency
RT-PRC005-EN
64
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional
Data
(3-5Tons)
All dimensions are in inches/millimeters.
DownflowAirflow Supply/Return
Through the Base Utilities
HorizontalAirflow Supply/Return
Unit Clearance and Roof Opening
RT-PRC005-EN
65
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional
Data
(3-5Tons)
All dimensions are in inches.
37 1/8”
928 MM
Downflow Duct Connections — Field Fabricated
RT-PRC005-EN
66
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional
Data
(6-10Tons)
All dimensions are in inches.
6Tons Standard and High Efficiency
7½Tons Standard Efficiency
7½Tons High Efficiency
8½ and 10Tons Standard and High Efficiency
RT-PRC005-EN
67
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional
Data
(6-10Tons)
All dimensions are in inches.
6-10Tons — Downflow Airflow Supply and Return;
Through the Base Utilities
Return
6-10Tons — Horizontal Airflow Supply and Return
Supply
6-10Tons — Unit Clearance and Roof Opening
RT-PRC005-EN
68
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional
Data
(6-10Tons)
All dimensions are in inches.
6-10Tons — Roof Curb
ALL FLANGES 1 1/4” (31 MM)
6-10Tons — Downflow Duct Connections —
Field Fabricated
RT-PRC005-EN
69
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional
Data
(3-5Tons Options/
Accessories)
All dimensions are in inches.
Barometric Relief Damper Hood
Economizer , Manual or Motorized Fresh Air Damper
Swing Diameter for Hinged Doors Option
See Page 65 for Through the Base Utilities Information
70
RT-PRC005-EN
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensional
Data
(6-10Tons Options/
Accessories)
All dimensions are in inches.
6-10Tons — Power Exhaust
6-10Tons — Economizer and Barometric
Relief Damper Hoods
6-10Tons — Swing Diameter for Hinged
Door(s) Option
See Page 68 for Through the Base Utilities Information
RT-PRC005-EN
71
Download from Www.Somanuals.com. All Manuals Search And Download.
Weights
TableW-1— Maximum Unit And CornerWeights (Lbs)And Center Of Gravity Dimensions (In.)
Maximum Weights (Lbs)
Corner Weights (Lbs)1
Center of Gravity (In.)
Unit
Model No.
Tons
Shipping2
Net
A
B
C
D
Length
Width
TSC036A
501
409
132
104
79
94
31
19
3
4
5
6
THC036A
TSC048A
THC048A
TSC060A
THC060A
518
526
560
543
610
426
434
468
451
518
139
140
146
149
165
108
110
113
114
124
84
91
95
94
32
33
31
31
31
19
19
20
18
19
97
88
111
99
105
124
TSC072A
THC072A
824
861
681
718
236
235
177
182
119
128
150
173
38
38
21
22
TSC090A
TSC092A
THC092A
897
899
1000
754
756
857
257
261
289
188
202
222
129
131
148
180
162
197
37
39
38
22
21
21
7½
8½
TSC102A
THC102A
978
1036
835
893
281
294
223
233
149
159
181
207
40
39
21
22
TSC120A
THC120A
1052
1125
909
982
306
323
241
253
164
178
197
229
40
39
21
22
10
NOTES:
1. Corner weights are given for information only.
2. Weights are approximate.
TableW-2 — Factory-installed Options NetWeights (Lbs)1,2
NetWeight
Accessory
Economizer
Barometric Relief
Powered Exhaust
Motorized Outside Air Damper
Manual Outside Air Damper
Roof Curb
3-5Tons
26
7
—
20
16
70
5
6-10Tons
36
10
80
30
26
115
8
Oversized Motor
Belt Drive Motor
31
7
5
12
10
38
8
15
5
—
7
5
20
12
38
13
30
5
Smoke Detector, Return
Smoke Detector, Supply
Coil Guards
Hinged Doors
Powered Convenience Outlet
Through the Base Electrical
Electric Heaters
Unit Mounted Circuit Breaker
Unit Mounted Disconnect
Novar Control
5
8
5
8
Dehumidification (Hot Gas Reheat) Coil
15
25
NOTES:
1.Weights for options not listed are < 5 lbs.
2.Net weight should be added to unit weight when ordering
factory-installed accessories.
RT-PRC005-EN
72
Download from Www.Somanuals.com. All Manuals Search And Download.
Mechanical
Specifications
General
UnitTop
be leak tested to 200 psig and pressure
tested to 450 psig.The condensor coil
shall have a patent pending 1 + 1 + 1
hybrid coil designed with slight gaps for
ease of cleaning. A removeable,
reversible, double-sloped condensate
drain pan with provision for through the
base condensate drain is standard.
The units shall be convertible airflow.
The operating range shall be between
115°F and 0°F in cooling as standard
from the factory for units with
The top cover shall be one piece
construction or where seams exist, it
shall be double-hemmed and gasket-
sealed. The ribbed top adds extra
strength and prevents water from
pooling on unit top.
microprocessor controls. Operating
range for units with electromechanical
controls shall be between 115°F and
40°F. Cooling performance shall be
rated in accordance with ARI testing
procedures. All units shall be factory
assembled, internally wired, fully
charged with R-22, and 100 percent run
tested to check cooling operation, fan
and blower rotation, and control
sequence before leaving the factory.
Wiring internal to the unit shall be
colored and numbered for simplified
identification. Units shall be UL listed
and labeled, classified in accordance to
UL 1995/CAN/CSA No. 236-M90 for
Central Cooling Air Conditioners.
Canadian units shall be CSA Certified.
Filters
One inch, throwaway filters shall be
standard on all 3-5 ton units.The filter
rack can be converted to two inch
capability.Two inch filters shall be factory
supplied on all 6-10 ton units. Optional 2-
inch pleated filters shall be available.
Outdoor Fans
The outdoor fan shall be direct-drive,
statically and dynamically balanced,
draw-through in the vertical discharge
position.The fan motor shall be
permanently lubricated and shall have
built-in thermal overload protection.
Compressors
All 3 ton standard units shall have direct-
drive, hermetic, reciprocating type
compressors.The reciprocating type
compressors have a centrifugal oil pump
providing positive lubrication to moving
parts. Motor shall be suction gas-cooled
and shall have a voltage utilization range
of plus or minus 10 percent of unit
nameplate voltage. Crankcase heater,
internal temperature, and current-
sensitive motor overloads shall be
included for maximum protection.
Compressors shall have internal spring
isolation and sound muffling to minimize
vibration transmission and noise. Low
pressure switches shall be standard.
Indoor Fan
All 3-5 ton 3-phase units offer a choice of
direct-drive, FC, centrifugal fans or belt
driven, FC centrifugal fans with
adjustable motor sheaves. 3-5 ton direct
drive oversized motors shall be available
for high static operations. All 6-10 ton
units shall have belt drive motors with
an adjustable idler-arm assembly for
quick-adjustment to fan belts and motor
sheaves. All motors shall be thermally
protected. All indoor fan motors meet
the U.S. Energy Policy Act of 1992
(EPACT).
Casing
Unit casing shall be constructed of zinc
coated, heavy gauge, galvanized steel.
Exterior surfaces shall be cleaned,
phosphatized, and finished with a
weather-resistant baked enamel finish.
Unit’s surface shall be tested 1000
hours in a salt spray test in compliance
with ASTM B117. Cabinet construction
shall allow for all maintenance on one
side of the unit. Service panels shall
have lifting handles and be removed
and reinstalled by removing only a
single fastener while providing a water
and air tight seal. All exposed vertical
panels and top covers in the indoor air
section shall be insulated with a
Controls
Unit shall be completely factory-wired
with necessary controls and contactor
pressure lugs or terminal block for
power wiring. Unit shall provide an
external location for mounting a fused
disconnect device.
3 ton high efficiency and 4-10 ton
standard and high efficiency units shall
have direct-drive, hermetic, scroll type
compressors with centrifugal type oil
pumps. Motor shall be suction gas-
cooled and shall have a voltage
utilization range of plus or minus 10
percent of unit nameplate voltage.
Internal overloads shall be provided with
the scroll compressors.
A choice of microprocessor or
electromechanical controls shall be
available.
cleanable foil-faced, fire-retardent
permanent, odorless glass fiber
material. The base of the unit shall be
insulated with 1/2 inch, 1 pound density
foil-faced, closed-cell material. All
insulation edges shall be either
captured or sealed.The unit’s base pan
shall have no penetrations within the
perimeter of the curb other than the
raised 11/8 inch high downflow supply/
return openings to provide an added
water integrity precaution, if the
Microprocessor controls provide for all
24 volt control functions.The resident
control algorithms shall make all
heating, cooling, and/or ventilating
decisions in response to electronic
signals from sensors measuring indoor
and outdoor temperatures.The control
algorithm maintains accurate
temperature control, minimizes drift
from set point, and provides better
building comfort. A centralized
Microprocessor shall provide anti-short
cycle timing and time delay between
compressors to provide a higher level of
machine protection.
Refrigerant Circuits
Each refrigerant circuit offers a choice of
independent fixed orifice expansion
devices or thermal expansion valve.
Service pressure ports, and refrigerant
line filter driers are factory-installed as
standard. An area shall be provided for
replacement suction line driers.
Evaporator and Condenser Coils
Internally finned, 5/16” copper tubes
mechanically bonded to a configured
aluminum plate fin shall be standard.
Coils shall be leak tested at the factory to
ensure the pressure integrity.The
condensate drain backs up.The base of
the unit shall have provisions for forklift
and crane lifting, with forklift
capabilities on three sides of the unit.
evaporator coil and condenser coil shall
RT-PRC005-EN
73
Download from Www.Somanuals.com. All Manuals Search And Download.
Mechanical
Specifications
Through the Base Electrical with Circuit
Breaker —This option is a factory-
installed, thermal magnetic, molded
case, HACR Circuit Breaker with
provisions for through the base electrical
connections.The circuit breaker will be
installed in a water tight enclosure in the
unit with access through a swinging
door. Factory wiring will be provided
from the switch to the unit high voltage
terminal block.The circuit breaker will
provide overcurrent protection, be sized
per NEC and UL guidelines, and be
agency recognized by UL/CSA.
operating position by the installing
contractor.
24-volt electromechanical control circuit
shall include control transformer and
contactor pressure lugs for power
wiring. Units shall have single point
power entry as standard.
Powered Exhaust —The field installed
powered exhaust, available for 6-10 ton
units, shall provide exhaust of return air,
when using an economizer, to maintain
better bulding pressurization.
Accessories/Options
Electric Heaters — Factory or field-
installed electric heat modules shall be
available for installation within basic
unit. Electric heater elements shall be
constructed of heavy-duty nickel
chromium elements internally delta
connected for 240 volt, wye connected
for 480 and 600 volt. Staging shall be
achieved through the unitary control
processor (UCP). Each heater package
shall have automatically reset high limit
control operating through heating
element contactors. All heaters shall be
individually fused from the factory,
where required, and shall meet all NEC
and CEC requirements when properly
installed. Power assemblies shall provide
single-point connection. Electric heat
modules shall be UL listed or CSA
certified.
Remote Potentiometer — The minimum
position setting of the economizer shall
be adjusted with this accessory.
Manual Outside Air Damper — Factory
or field-installed rain hood and screen
shall provide up to 50 percent outside air.
Powered or Unpowered Convenience
Outlet —This factory-installed option is a
GFCI, 120v/15amp, 2 plug, convenience
outlet, either powered or unpowered.
When the convenience outlet is
powered, a service receptacle disconnect
will be available.The convenience outlet
is powered from the line side of the
disconnect or circuit breaker, and
therefore will not be affected by the
position of the disconnect or circuit
breaker.This option can only be ordered
when theThrough the Base Electrical
with either the Disconnect Switch or
Circuit Breaker option is ordered.
Motorized OutsideAir Dampers —
Factory or field-installed manually set
outdoor air dampers shall provide up to
50 percent outside air. Once set, outdoor
air dampers shall open to set position
when indoor fan starts.The damper shall
close to the full closed position when
indoor fan shuts down.
DischargeAir Sensing —This factory or
field-installed option provides true
discharge air sensing in heating models.
This sensor is a status indicator readable
throughTracer® orTracker®. This option
is available for microprocessor
Roof Curb — The roof curb shall be
designed to mate with the unit’s
controlled units.
Clogged Filter/Fan Failure Switch — A
dedicated differential pressure switch is
available, factory-installed, to achieve
active fan failure indication and/or
clogged filter indication.These
indications will be registered with either
a zone sensor with status indication
lights or an Integrated Comfort™
System.This option is available for
microprocessor controlled units.
downflow supply and return and provide
support and a water tight installation
when installed properly.The roof curb
design shall allow field-fabricated
rectangular supply/return ductwork to be
connected directly to the curb. Curb
design shall comply with NRCA
requirements. Curb shall be shipped
knocked down for field assembly and
shall include wood nailer strips.
Oversized Motors — Factory or field-
installed direct drive oversized motors
shall be available for high static
applications.
Through the Base Electrical Access —
An electrical service entrance shall be
factory provided allowing electrical
access for both control and main power
connections inside the curb and through
the base of the unit. Option will allow for
field installation of liquid-tight conduit
and an external field-installed disconnect
switch.
Reference or Comparative Enthalpy —
Factory-installed Reference or
Comparative Enthalpy option shall be
available when a factory-installed
Economizer is ordered.This option is
available for microprocessor controlled
units.
Economizer — This accessory shall be
either field or factory-installed and shall
be available with or without barometric
relief.The assembly includes fully
modulating 0-100 percent motor and
dampers, minimum position setting,
preset linkage, wiring harness with plug,
spring return actuator and fixed dry bulb
control.The barometric relief shall
provide a pressure operated damper that
shall be gravity closing and shall prohibit
entrance of outside air during the
equipment “off” cycle. Optional solid
state or differential enthalpy control shall
be available for either factory or field
installation.The factory-installed
economizer arrives in the shipping
position and shall be moved to the
Through the Base Electrical with
Disconnect Switch — Factory-installed 3-
pole, molded case, disconnect switch
with provisions for through the base
electrical connections are available.The
disconnect switch will be installed in the
unit in a water tight enclosure with
access through a swinging door. Factory
wiring will be provided from the switch
to the unit high voltage terminal block.
The switch will be UL/CSA agency
recognized. Note:The disconnect switch
will be sized per NEC and UL guidelines
but will not be used in place of unit
overcurrent protection.
High Pressure Cutout —This factory-
installed option is offered for units that
do not have High Pressure cutout as
standard. All 3-phase units with scroll
compressors include High Pressure
Cutout as standard.
Hinged Access Doors — Sheet metal
hinges are available factory-installed on
the Filter/Evaporator, Supply Fan/Heat,
and the Compressor/Control Access
Doors.
RT-PRC005-EN
74
Download from Www.Somanuals.com. All Manuals Search And Download.
Mechanical
Specifications
Supply and/or Return Air Smoke
Detector —With this option factory-
installed, if smoke is detected, all unit
operation will be shut down. Reset will
be manual at the unit. Return Air Smoke
Detectors require minimum allowable
airflow when used with certain models.
See the Installation, Operation, and
Maintenance (IOM) manual for the
models affected and the minimum
allowable airflow required.This option is
available for microprocessor controlled
units.
Thermostat —Two stage heating and
cooling operation or one stage heating
and cooling shall be available, for field
installation, in either manual or
automatic changeover. Automatic
programmable electronic with night set
back shall also be available.
Novar Unit Controls — Optional Novar
rooftop unit controls shall be factory
installed and tested. The Novar
electronic thermostat module will
interface to the unit microprocesser and
will control the unit to the desired stage
of cooling or heating.
Differential Pressure Switches —These
factory or field-installed sensors allow
individual fan failure and dirty filter
indication for microprocessor controlled
units.The fan failure switch will disable
all unit functions and “flash” the Service
LED on the zone sensor.The dirty filter
switch will light the Service LED on the
zone sensor and will allow continued
unit operation.
Novar ReturnAir Sensor —This option,
when used in conjunction with Novar
Controls, will contain a factory provided
and wired zone temperature snesor
located in the return air stream.
CO2 Sensing —The CO2 sensor shall
have the ability to to monitor space
occupancy levels within the building by
measuring the parts per million of CO2
(Carbon Dioxide) in the air. As the CO2
levels increase, the outside air damper
modulates to meet the CO2 space
ventilation requirements.The CO2
accessory shall be available as field
installed.
Black Epoxy Coated Condenser Coil —
The coil provides corrosion protection to
condenser coils for seacoast application.
The protection is a factory-applied
thermoset vinyl coating, bonded to
normal aluminum fin stock.The uniform
thickness of the bonded vinyl layer
exhibits excellent corrosion protection in
salt spray tests performed in accordance
with ASTM B117.
Enthalpy Control — Replaces the dry
bulb control with a wet bulb changeover
controller which has a fully adjustable
set point. Enthalpy control offers a
higher level of comfort control, along
with energy savings potential, than the
standard dry bulb control. This is due to
the additional wet bulb sensing
capability.This option shall be available
for microprocessor controlled units. It
can be field-installed, or factory-installed
with the factory-installed economizer.
Ventilation OverrideAccessory —With
theVentilation Override Accessory
installed, the unit can be set to transition
to up to 3 different pre-programmed
sequences for Smoke Purge,
Dehumidification Option —The
dehumidification (hot gas reheat) option
shall be a factory-installed option that
provides increased dehumidification.The
option shall consist of a hot-gas reheat
coil located on the leaving air side of the
evaporator coil prepiped and circuited.
Pressurization, and Exhaust.The
transition occurs when a binary input on
the RTOM is closed (shorted).This would
typically be a hard wired relay output
from a smoke detector of fire control
panel.The ventilation override accessory
shall be available as field installed.
Differential Enthalpy — Replaces the
standard dry bulb control with two
enthalpy sensors that compare total heat
content of the indoor air and outdoor air
to determine the most efficient air
source.This control option offers the
highest level of comfort control, plus
energy efficiency, available.This option
shall be available for microprocessor
controlled units. It can be field-installed,
or factory-installed with the factory-
installed economizer.
The option shall be equipped with
crankcase heater(s), low pressure
switch(es), Frostat™, and a thermostatic
expansion valve(s) (TXV) as standard.
Control Options
Humidity Sensor (BAYSENS036) —Field
installed, wall-mounted humidity sensor
is used to control activation of the hot
gas reheat dehumidification option.The
humidity sensor can be set for humidity
levels between 40% and 60% relative
humidity by adjusting the ReliaTel
Options Module.
Trane Communication Interface — This
factory or field-installed option shall be
provided to interface microprocessor
controlled units with theTrane Integrated
ComfortTM systems.
LowAmbient Cooling — All
LonTalk® Communication Interface —
This factory or field-installed option shall
be provided to allow the unit to
communicate as aTracer™LCI-R device
or directly with generic LonTalk Network
Building Automation System Controls.
microprocessor units shall have cooling
capabilities down to 0°F as standard.
Electromechanical models have cooling
capabilites to 40°F as built, or to 0°F by
adding the optional low ambient (frostat)
control.
Humidity Sensor (BAYSENS037) —Field
installed, duct-mounted humidity sensor
is used to control activation of the hot
gas reheat dehumidification option.The
humidity sensor can be set for humidity
levels between 40% and 60% relative
humidity by adjusting the ReliaTel
Options Module.
Zone Sensor —This field-installed
control shall be provided to interface
with the Micro equipped units and shall
be available in either manual, automatic
programmable with night setback, with
system malfunction lights, or remote
sensor options.
Thermal ExpansionValve — All units
shall have a short orifice refrigerate
control metering device. For more exact
refrigerant flow, when using unit in low
airflow applications, aThermal
ExpansionValve option shall be
available.
RT-PRC005-EN
75
Download from Www.Somanuals.com. All Manuals Search And Download.
*High Efficiency Units only
Literature Order Number
File Number
RT-PRC005-EN
PL-UN-RT-TSC/THC 3-10TONS-PRC005-EN-03-03
PL-UN-RT-TSC/THC 3-10TONS-PRC005-EN-02-03
March Publication Electronic Only
Supersedes
Trane
Stocking Location
A business of American Standard Companies
For more information contact your local dealer
(distributor), local district office, or e-mail us at
Trane has a policy of continuous product and product data improvement and reserves the right to change
design and specifications without notice.