Trane Fan 4TTB4 User Manual

Split System  
Cooling  
Product Data  
XB14 4TTB4  
1 1/2 - 5 Tons (018E - 061E)  
PUB. NO. 22-1833-09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features and Benefits  
2
General Data  
4
4
4
6
6
Product Specifications  
A-Weighted Sound Power Level [dB(A)]  
Accessory Description and Usage  
AHRI Standard Capacity Rating Conditions  
Model Nomenclature  
Electrical Data  
7
8
Dimensions  
13  
16  
Mechanical Specification Options  
22-1833-09  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Data  
Product Specifications  
4TTB4024E1  
Model No. 1  
4TTB4018E1  
4TTB4030E1  
4TTB4036E1  
Electrical Data V/Ph/Hz 2  
Min Cir Ampacity  
Max Fuse Size (Amps)  
208/230/1/60  
208/230/1/60  
208/230/1/60  
208/230/1/60  
9
15  
9
15  
12  
20  
19  
30  
Compressors  
CLIMATUFF®  
CLIMATUFF®  
CLIMATUFF®  
CLIMATUFF® - SCROLL  
No. Used - No. Stages  
RL AMPS - LR AMPS  
Outdoor Fan FL Amps  
Fan HP  
1-1  
6.4 - 38.6  
0.74  
1-1  
6.8 - 38.6  
0.74  
1-1  
9.1 - 57.8  
0.93  
1/5  
27.6  
1-1  
14.1 - 77  
0.93  
1/5  
27.6  
1/8  
23  
1/8  
23  
Fan Dia (inches)  
Coil  
Spine Fin™  
5/2-LB/OZ  
5/8  
Spine Fin™  
6/3-LB/OZ  
3/4  
Spine Fin™  
7/0-LB/OZ  
3/4  
Spine Fin™  
7/4-LB/OZ  
3/4  
Refrigerant R-410A  
Line Size - (in.) O.D. Gas 3  
Line Size - (in.) O.D. Liquid 3  
3/8  
3/8  
3/8  
3/8  
Dimensions H x W x D (Crated)  
Weight - Shipping  
Weight - Net  
34 x 30.1 x 33  
34 x 30.1 x 33  
38.4 x 35.1 x 38.7  
42.4 x 35.1 x 38.7  
200  
173  
201  
174  
234  
201  
228  
193  
Start Components  
Sound Enclosure  
Compressor Sump Heat  
YES  
YES  
NO  
YES  
YES  
NO  
YES  
YES  
NO  
NO  
NO  
NO  
Optional Accessories: 4  
Anti-short Cycle Timer  
Evaporator Defrost Control A/C  
Rubber Isolator Kit  
Crank Case Heater Kit  
Hard Start Kit Scroll  
Extreme Condition Mounting Kit  
Snow Leg - Base & Cap 4" High  
Snow Leg - 4" Extension  
Seacoast Kit  
TAYASCT501A  
AY28X079  
BAYISLT101  
BAYCCHT300  
TAYASCT501A  
AY28X079  
BAYISLT101  
BAYCCHT300  
TAYASCT501A  
AY28X079  
BAYISLT101  
BAYCCHT300  
TAYASCT501A  
AY28X079  
BAYISLT101  
BAYCCHT302  
BAYKSKT260  
BAYECMT004  
BAYLEGS002  
BAYLEGS003  
BAYSEAC001  
TAYREFLN7*  
BAYECMT023  
BAYLEGS002  
BAYLEGS003  
BAYSEAC001  
TAYREFLN950  
BAYECMT023  
BAYLEGS002  
BAYLEGS003  
BAYSEAC001  
TAYREFLN7*  
BAYECMT004  
BAYLEGS002  
BAYLEGS003  
BAYSEAC001  
TAYREFLN7*  
Refrigerant Lineset 5  
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification  
program which is based on AHRI Standard 210/240.  
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.  
3 Standard line lengths - 80'. Standard lift - 60' Suction and Liquid line.  
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. (denotes  
latest revision)  
4 For accessory description and usage, see pages 5 and 6.  
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.  
A-Weighted Sound Power Level [dB(A)]  
A_WEIGHTED FULL OVTAVE SOUND POWER LEVEL dB - [dB(A)]  
SOUND POWER  
LEVEL [dB(A)]  
MODEL  
63  
125  
250  
500  
1000  
2000  
4000  
8000  
4TTB4018E  
4TTB4024E  
4TTB4030E  
4TTB4036E  
4TTB4042E  
4TTB4048E  
4TTB4049E  
4TTB4060E  
4TTB4061E  
79  
79  
80  
78  
80  
80  
76  
80  
76  
24.9  
23  
44.9  
45.4  
52.9  
51.7  
52.8  
52.8  
53.8  
52.8  
53.8  
56.7  
57  
71.1  
70.9  
74.3  
72.3  
73.3  
73.3  
63.6  
73.3  
66  
74.1  
74.2  
76.2  
74.1  
75.1  
75.1  
34.6  
75.1  
65.7  
72.7  
70.5  
73  
62.2  
62.9  
64.7  
62.7  
62.8  
62.8  
52.7  
62.8  
58.4  
49.9  
52.6  
52.5  
49.5  
50  
27.9  
23.2  
22.8  
22.8  
44.3  
22.8  
42.2  
62.9  
64.2  
65.6  
65.6  
56.6  
65.6  
57.8  
71.3  
75.1  
75.1  
59.9  
71.5  
57.7  
50  
43.7  
50  
51.7  
Note: Rated in accordance with AHRI Stnadard 270-2008  
4
22-1833-09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Data  
Product Specifications  
Model No. 1  
4TTB4042E1  
4TTB4048E1  
4TTB4049E1  
4TTB4060E1  
4TTB4061E1  
Electrical Data V/Ph/Hz 2  
Min Cir Ampacity  
Max Fuse Size (Amps)  
208/230/1/60  
208/230/1/60  
208/230/1/60  
208/230/1/60  
230/1/60  
45  
60  
23  
40  
26  
45  
26  
45  
34  
60  
Compressors  
CLIMATUFF® - SCROLL  
CLIMATUFF® - SCROLL  
CLIMATUFF® - SCROLL  
CLIMATUFF® - SCROLL  
CLIMATUFF® - SCROLL  
No. Used - No. Stages  
RL AMPS - LR AMPS  
Outdoor Fan FL Amps  
Fan HP  
1-1  
17.9 - 112  
0.93  
1/5  
27.6  
1-1  
19.9 - 109  
0.93  
1/5  
27.6  
1-1  
19.9 - 109  
1.0  
1/5  
27.6  
1-1  
26.4 - 134  
0.93  
1/5  
27.6  
1-2  
32.1 - 152.9  
2.80  
1/3  
27.6  
Fan Dia (inches)  
Coil  
Spine Fin™  
8/4-LB/OZ  
7/8  
Spine Fin™  
8/5-LB/OZ  
7/8  
Spine Fin™  
11/9-LB/OZ  
7/8  
Spine Fin™  
8/8-LB/OZ  
7/8  
Spine Fin™  
12/9-LB/OZ  
1-1/8  
Refrigerant R-410A  
Line Size - (in.) O.D. Gas 3  
Line Size - (in.) O.D. Liquid 3  
3/8  
3/8  
3/8  
3/8  
3/8  
Dimensions H x W x D (Crated) 46.4 x 35.1 x 38.7  
51 x 35.1 x 38.7  
51 x 35.1 x 38.7  
51 x 35.1 x 38.7  
51 x 35.1 x 38.7  
Weight - Shipping  
Weight - Net  
272  
235  
282  
245  
304  
267  
285  
248  
312  
275  
Start Components  
Sound Enclosure  
Compressor Sump Heat  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
NO  
Optional Accessories: 4  
Anti-short Cycle Timer  
Evaporator Defrost Control A/C  
Rubber Isolator Kit  
Crank Case Heater Kit  
Hard Start Kit Scroll  
Extreme Condition Mounting Kit BAYECMT004  
Snow Leg - Base & Cap 4" High BAYLEGS002  
Snow Leg - 4" Extension  
Seacoast Kit  
TAYASCT501A  
AY28X079  
BAYISLT101  
BAYCCHT301  
BAYKSKT260  
TAYASCT501A  
AY28X079  
TAYASCT501A  
AY28X079  
TAYASCT501A  
AY28X079  
BAYISLT101  
BAYCCHT301  
TAYASCT501A  
AY28X079  
BAYISLT101  
BAYCCHT301  
BAYISLT101  
BAYCCHT301  
BAYKSKT260  
BAYECMT004  
BAYLEGS002  
BAYLEGS003  
BAYSEAC001  
TAYREFLN3*  
BAYISLT101  
BAYCCHT301  
BAYKSKT260  
BAYECMT004  
BAYLEGS002  
BAYLEGS003  
BAYSEAC001  
TAYREFLN3*  
BAYECMT004  
BAYLEGS002  
BAYLEGS003  
BAYSEAC001  
TAYREFLN3*  
BAYECMT004  
BAYLEGS002  
BAYLEGS003  
BAYSEAC001  
TAYREFLN*4  
BAYLEGS003  
BAYSEAC001  
TAYREFLN3*  
Refrigerant Lineset 5  
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.  
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.  
3 Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For 061 units, Max. linear length 60 ft.; Max. lift - Suction 25 ft.; Max lift - Liquid 25 ft.  
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0. (denotes latest revision)  
4 For accessory description and usage, see pages 5 and 6.  
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.  
22-1833-09  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
General Data  
Accessory Description and Usage  
AHRI Standard Capacity Rating Conditions  
Anti-Short Cycle Timer — Solid state timing device that  
prevents compressor recycling until 5 minutes have elapsed  
after satisfying call or power interruptions. Use in area with  
questionable power delivery, commercial applications, long  
lineset, etc.  
AHRI STANDARD 210/240 RATING CONDITIONS —  
(A) Cooling 80°F DB, 67°F WB air entering indoor coil,  
95°F DB air entering outdoor coil.  
AHRI STANDARD 270 RATING CONDITIONS —  
(Noise rating numbers are determined with the unit in cooling  
operation.) Standard Noise Rating number is at 95°F outdoor  
air.  
Evaporator Defrost Control — SPST Temperature actuated  
switch that cycles the condenser off as indoor coil reaches  
freeze-up conditions. Used for low ambient cooling to 30°F  
with TXV.  
Rubber Isolators —  
5
large rubber donuts to isolate  
condensing unit from transmitting energy into mounting frame  
or pad. Use on any application where sound transmission  
needs to be minimized.  
Hard Start kit — Start capacitor and relay to assist  
compressor motor startup. Use in areas with marginal power  
supply, on long linesets, low ambient conditions, etc.  
Extreme Condition Mount Kit — Bracket kits to securely  
mount condensing unit to a frame or pad without removing  
any panels. Use in areas with high winds, or on commercial  
roof tops, etc.  
6
22-1833-09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Model Nomenclature  
T
U
D
2
B
0
8
0
A
C
V
3
2
A
A
4 T  
T
B
4
0
3
6
E
1
0
0
0 A  
A
Gas Furnaces  
Outdoor Units  
Refrigerant Type  
2 = R-22  
4 = R-410A  
TRANE  
Product Type  
W = Split Heat Pump  
T = Split Cooling  
Product Family  
Z = Leadership – Two Stage  
X = Leadership  
R = Replacement/Retail  
B = Basic  
A = Light Commercial  
Family SEER  
0 = 10  
1 = 11  
2 = 12  
3 = 13  
4 = 14  
5 = 15  
6 = 16  
8 = 18  
9 = 19  
Split System Connections 1-6 Tons  
0 = Brazed  
Nominal Capacity in 000s of BTUs  
Major Design Modifications  
Power Supply  
1 = 200-230/1/60 or 208-230/1/60  
3 = 200-230/3/60  
4 = 460/3/60  
Secondary Function  
Minor Design Modifications  
Unit Parts Identifier  
4
T
E
E
3
F
3
6
A
1
0
0
0
A
A
Air Handlers –  
Residential  
4
T
X
C
B
0
0
1
C
C
3
H
C
A
A
Coils –  
Residential  
Refrigerant Type  
4 = R-410A  
RefrigerantType  
4 - R410A  
Application  
Product Family  
T-Premium  
(HeatPumporConvertibleCoil)  
TE = Fully Convertible  
TG = Semi Convertible  
TF = Front Return  
Coil Design  
X - Direct Expansion Evaporator Coil  
Product Family  
E = Leadership – Variable Speed  
P = Leadership  
Product Family  
C - Cased A Coil  
A - Uncased A Coil  
F - Cased Horizontal Flat Coil  
C = Replacement/Retail  
B = Basic  
CoilWidth(Cased/Uncased)  
A - 14.5" / 13.3"  
B - 17.5" / 16.3"  
C - 21.0" / 19.8"  
D - 24.5" / 23.3"  
H - 10.5"  
Flow Control  
0 = No Flow Control  
3 = Nonbleed TXV  
Feature Identifier  
0 = Standard Unit  
F = Air-Tite™  
RefrigerantLineCoupling  
0 - Brazed  
Nominal Capacity in 1000’s (BTUH)  
Major Design Change  
ModelNumberDistinguisher  
MajorDesignChange  
Power Supply  
1 = Single Phase  
Efficiency  
C - Standard  
Electrical Connection  
0 = Pig Tails  
B = Circuit Breaker  
D = Pull Disconnect  
S - Hi Efficiency (Derived from 10 SEER products)  
RefrigerantControl  
3 - TXV - Non-Bleed  
Coil Circuitry  
Future Option – Factory Installed Heater Nominal KW Value  
Minor Design Modifications  
H - Heat Pump  
AirflowConfiguration  
A - Upflow Only  
Unit Parts Identifier  
U - Upflow / Downflow  
H - Horizontal Only  
NOTE: There will be a phase-in of new model numbers for new  
air handlers over next 2 years.  
C - Convertible - Upflow, Downflow, Left or Right Airflow  
MinorDesignChange  
UnitPartsIdentifier  
22-1833-09  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Data  
Schematic Diagrams  
4TTB4018, 4TTB4024, 4TTB4030  
From Drawing D157123P01REV0  
8
22-1833-09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Data  
Schematic Diagrams  
4TTB4036, 4TTB4042  
From Drawing D157124P01  
22-1833-09  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Data  
Schematic Diagrams  
4TTB4048, 4TTB4049  
From Drawing D157125P01  
10  
22-1833-09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Data  
Schematic Diagrams  
4TTB4060  
From Drawing D157126P01  
22-1833-09  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Electrical Data  
Schematic Diagrams  
4TTB4061  
From Drawing D156975p01  
12  
22-1833-09  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Dimensions  
4TTB4 Outline Drawing  
Note: All dimensions are in MM (Inches).  
MODELS  
BASE  
A
B
C
D
E
F
G
H
J
K
4TTB4018E  
4TTB4024E  
4TTB4030E  
4TTB4036E  
4TTB4042E  
4TTB4048E  
4TTB4049E  
4TTB4060E  
4TTB4061E  
3
3
4
4
4
4
4
4
4
730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 5/8  
730 (28-3/4) 829 (32-5/8) 756 (29-3/4) 3/4  
841 (33-1/8) 946 (37-1/4) 870 (34-1/4) 3/4  
943 (37-1/8) 946 (37-1/4) 870 (34-1/4) 3/4  
1045 (41 1/8) 946 (37-1/4) 870 (34-1/4) 7/8  
1147 (45 1/8) 946 (37-1/4) 870 (34-1/4) 7/8  
1147 (45 1/8) 946 (37-1/4) 870 (34-1/4) 7/8  
1147 (45 1/8) 946 (37-1/4) 870 (34-1/4) 7/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
3/8  
127 (5)  
127 (5)  
152 (6)  
152 (6)  
152 (6)  
152 (6)  
152 (6)  
152 (6)  
152 (6)  
76 (3)  
76 (3)  
197 (7-3/4) 57 (2-1/4)  
197 (7-3/4) 57 (2-1/4)  
508 (20)  
508 (20)  
508 (20)  
508 (20)  
508 (20)  
508 (20)  
508 (20)  
508 (20)  
508 (20)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)  
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)  
1147 (45 1/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8  
From Dwg. D156010  
22-1833-09  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Notes  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22-1833-09  
Notes  
22-1833-09  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mechanical Specification  
Options  
General  
Condenser Coil  
The 4TTB4 is fully charged from the  
factory for up to 15 feet of piping. This  
unit is designed to operate at outdoor  
The outdoor coil provides low airflow  
resistance and efficient heat transfer.  
The coil is protected on all four sides by  
ambient temperatures as high as 115°F. louvered panels.  
Cooling capacities are matched with  
Low Ambient Cooling  
a wide selection of air handlers and  
furnace coils that are AHRI certified. The  
unit is certified to UL 1995. Exterior is  
designed for outdoor application.  
As manufactured, this unit has a cooling  
capability to 55°F. The addition of an  
evaporator defrost control with TXV  
permits low ambient cooling to 30° F.  
Casing  
Accessories  
Unit casing is constructed of heavy  
gauge, G90 galvanized steel and  
painted with a weather-resistant powder  
paint on all louvers, panels, prepaint  
on all other panels. Corrosion and  
weatherproof CMBP-G30 DuraTuff™  
base.  
Thermostats  
Cooling only and  
heat/cooling (manual and automatic  
changeover). Sub-base to match  
thermostat and locking thermostat cover.  
Refrigerant Controls  
Refrigeration system controls include  
condenser  
fan  
and  
compressor  
contactor. High and low pressure  
controls are inherent to the compressor.  
A factory installed liquid line drier is  
standard.  
Compressor  
The Climatuff® compressor features  
internal over temperature and pressure  
protection and total dipped hermetic  
motor. Other features include: roto  
lock suction and discharge refrigerant  
connections, centrifugal oil pump and  
low vibration and noise.  
01/12  
The manufacturer has a policy of continuous product and product data improvement and it reserves the right  
to change design and specifications without notice.  
Trane  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tektronix TV Converter Box P6701B User Manual
Texas Instruments Battery Charger BQ2461X User Manual
Toastmaster Can Opener 2238 User Manual
Topfield Satellite TV System TF6400IR User Manual
Toshiba Computer Drive 593209 A0 User Manual
Toshiba Computer Hardware 386SX User Manual
Toshiba PDAs Smartphones e755 User Manual
Transcend Information Computer Drive StoreJet 25 Version 13 User Manual
TRENDnet Router Not available User Manual
Valcom Welding System vp 4024b User Manual