Split System
Cooling
Product Data
XL16i
4TTX6024, 036, 048 & 060E
2, 3, 4 & 5 Tons
PUB. NO. 22-1752-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Contents
features and Benefits
2
General Data
4
4
4
5
5
Product Specifications
A-weighted Sound Power Level [dB(A)]
Accessory Description and Usage
AHRI Standard Capacity Rating Conditions
model Nomenclature
Electrical Data
6
7
8
9
Dimensions
mechanical Specifications
22-1752-10
3
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
Product Specifications
Model No. 1
4TTX6024E1
4TTX6036E1
4TTX6048E1
4TTX6060E1
Electrical Data V/Ph/Hz 2
Min Cir Ampacity
Max Fuse Size (Amps)
230/1/60
14
20
230/1/60
22
35
230/1/60
29
50
230/1/60
39
60
Compressor
CLIMATUFF® - SCROLL
CLIMATUFF® - SCROLL
CLIMATUFF® - SCROLL
CLIMATUFF® - SCROLL
RL AMPS - LR AMPS
Outdoor Fan FL Amps
Fan HP
10.3 - 52
0.74
1/8
16.7 - 82
0.74
1/8
21.2 - 104
2.80
1/3
28.8 - 152.9
2.80
1/3
Fan Dia (inches)
27.6
27.6
27.6
27.6
Coil
Spine Fin™
9/13-LB/OZ
5/8
Spine Fin™
9/13-LB/OZ
3/4
Spine Fin™
12/9-LB/OZ
7/8
Spine Fin™
12/9-LB/OZ
1-1/8
Refrigerant R-410A
Line Size - (in.) O.D. Gas 3
Line Size - (in.) O.D. Liquid 3
3/8
3/8
3/8
3/8
Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7
57.4 x 35.1 x 38.7
57.4 x 35.1 x 38.7
57.4 x 35.1 x 38.7
Weight - Shipping
Weight - Net
309
261
316
266
328
291
332
295
Start Components
Sound Enclosure
Compressor Sump Heat
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
NO
Optional Accessories: 4
Rubber Isolator Kit
Snow Leg - Base & Cap 4" High
Snow Leg - 4" Extension
Hard Start Kit Scroll
BAYISLT101
BAYLEGS002
BAYLEGS003
BAYKSKT260
BAYCCHT301
BAYECMT023
BAYVDTA003
BAYCAKT001
TAYREFLN9*
BAYISLT101
BAYLEGS002
BAYLEGS003
BAYKSKT260
BAYCCHT301
BAYECMT004
BAYVDTA004
BAYCAKT001
TAYREFLN7*
BAYISLT101
BAYLEGS002
BAYLEGS003
BAYKSKT260
BAYCCHT301
BAYECMT004
BAYVDTA004
BAYCAKT001
TAYREFLN3*
BAYISLT101
BAYLEGS002
BAYLEGS003
BAYKSKT260
BAYCCHT301
BAYECMT004
BAYVDTA004
BAYCAKT001
TAYREFLN4*
Crankcase Heater Kit
Extreme Condition Mounting Kit
Vertical Discharge Air Kit Base 4
Auto Charge Solenoid Kit
Refrigerant Lineset 5
1 Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on AHRI Standard 210/240.
2 Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
3 Standard line lengths - 60'. Standard lift - 25' Suction and Liquid line.
For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0†. (†denotes latest revision)
4 For accessory description and usage, see page 5.
5 * = 15, 20, 25, 30, 40 and 50 foot lineset available.
A-weighted Sound Power Level [dB(A)]
SOUND POWER
LEVEL [dB(A)]
A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)]
MODEL
63
125
250
500
1000
2000
4000
8000
4TTX6024E
4TTX6036E
4TTX6048E
4TTX6060E
72
72
73
74
43.7
52.6
54.3
62.4
60.4
57
54.1
46.6
38
50.4
50.4
53.8
56.8
58.9
57.8
60.4
63.1
66
59.8
63
57.2
57.4
57.7
55.2
53.6
58.4
49.2
47.4
51.7
44.2
42.2
65.7
Note: Rated in accordance with AHRI Standard 270-2008.
4
22-1752-10
Download from Www.Somanuals.com. All Manuals Search And Download.
General
Data
accessory Description and Usage
ahRi Standard Capacity Rating Conditions
ahRi STaNDaRD 210/240 RaTiNG CONDiTiONS —
(A) Cooling 80°F DB, 67°F WB air entering indoor coil,
95°F DB air entering outdoor coil.
(B) High Temperature Heating 47°F DB, 43°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
Rubber isolators — 5 rubber donuts to isolate condens-
ing unit from mounting frame or pad. Use on any application
where sound transmission needs to be minimized.
Extreme Conditions mounting kit — Bracket kits to secure-
ly mount condensing unit to a frame or pad without removing
any panels. Use in areas with high winds, or on commercial
rooftops, etc.
(D) Rated indoor airflow for heating is the same as for cooling.
Low ambient Cooling — For low ambient cooling below 55°
see Application Guide APP-APG013-EN.
ahRi STaNDaRD 270 RaTiNG CONDiTiONS — (Noise
rating numbers are determined with the unit in cooling opera-
tion.) Standard Noise Rating number is at 95°F outdoor air.
22-1752-10
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Model
Nomenclature
T
U
D
2
B
0
8
0
A
C
V
3
2
A
A
4 T
T
X
6
0
3
6
E
1
0
0
0 A
A
Gas Furnaces
Outdoor Units
Refrigerant Type
4 = R-410A
TRANE
Product Type
W = Split Heat Pump
T = Split Cooling
Product Family
Z = Leadership – Two Stage
X = Leadership
R = Replacement/Retail
M or B = Basic
A = Light Commercial
Family SEER
3 = 13
4 = 14
5 = 15
6 = 16
8 = 18
9 = 19
0 = 20
Split System Connections 1-6 Tons
0 = Brazed
Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply
1 = 200-230/1/60 or 208-230/1/60
3 = 200-230/3/60
4 = 460/3/60
Secondary Function
Minor Design Modifications
Unit Parts Identifier
4
T
X
C
B
0
0
1
C
C
3
H
C
A
A
4
T
E
E
3
F
3
6
A
1
0
0
0
A
A
Coils –
Air Handlers –
Residential
Residential
RefrigerantType
Refrigerant Type
4 - R410A
4 = R-410A
Product Family
T-Premium
(HeatPumporConvertibleCoil)
Application
TE = Fully Convertible
TG = Semi Convertible
TF = Front Return
Coil Design
X - Direct Expansion Evaporator Coil
Product Family
C - Cased A Coil
Product Family
E = Leadership – Variable Speed
P = Leadership
A - Uncased A Coil
F - Cased Horizontal Flat Coil
C = Replacement/Retail
B = Basic
CoilWidth(Cased/Uncased)
A - 14.5" / 13.3"
B - 17.5" / 16.3"
C - 21.0" / 19.8"
D - 24.5" / 23.3"
H - 10.5"
Flow Control
0 = No Flow Control
3 = Nonbleed TXV
RefrigerantLineCoupling
Feature Identifier
0 = Standard Unit
F = Air-Tite™
0 - Brazed
ModelNumberDistinguisher
MajorDesignChange
Nominal Capacity in 1000’s (BTUH)
Major Design Change
Efficiency
C - Standard
Power Supply
1 = Single Phase
S - Hi Efficiency (Derived from 10 SEER products)
RefrigerantControl
Electrical Connection
0 = Pig Tails
B = Circuit Breaker
D = Pull Disconnect
3 - TXV - Non-Bleed
Coil Circuitry
H - Heat Pump
AirflowConfiguration
A - Upflow Only
Future Option – Factory Installed Heater Nominal KW Value
Minor Design Modifications
U - Upflow / Downflow
H - Horizontal Only
Unit Parts Identifier
C - Convertible - Upflow, Downflow, Left or Right Airflow
NOTE: There will be a phase-in of new model numbers for new
air handlers over next 2 years.
MinorDesignChange
UnitPartsIdentifier
6
22-1752-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
(SEE LEGEND)
4TTX6024E, 036E
Printed from D156630P02 Rev 00
22-1752-10
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
(SEE LEGEND)
4TTX6048E, 060E
8
22-1752-10
Download from Www.Somanuals.com. All Manuals Search And Download.
Electrical
Data
Schematic Diagrams
LEGEND
22-1752-10
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Dimensions
4TTX6 Outline Drawing
Note: all dimensions are in mm (inches).
mODELS
BaSE
a
B
C
D
E
f
G
h
J
k
4TTX6024E
4TTX6036E
4TTX6048E
4TTX6060E
4
4
4
4
1267 (49-7/8) 946 (37-1/4) 870 (34-1/4)
1369 (53-7/8) 946 (37-1/4) 870 (34-1/4)
1369 (53-7/8) 946 (37-1/4) 870 (34-1/4)
5/8
3/4
7/8
3/8
3/8
3/8
152 (6)
152 (6)
152 (6)
152 (6)
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)
730 (28-3/4)
98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 1035 (40-3/4)
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)
98 (3-7/8) 219 (8-5/8) 86 (3-3/8)
730 (28-3/4)
730 (28-3/4)
1369 (53-7/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8
From Dwg. D152635 Rev. 16
22-1752-10
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Mechanical
Specifications
General
Condenser Coil
The 4TTX6 is fully charged from the fac-
tory for matched indoor section and up
to 15 feet of piping. This unit is designed
to operate at outdoor ambient tempera-
tures as high as 115°F. Cooling capaci-
ties are matched with a wide selection
of air handlers and furnace coils that are
AHRI certified. The unit shall be certi-
fied to UL 1995. Exterior is designed for
outdoor application.
The outdoor coil provides low airflow
resistance and efficient heat transfer.
The coil is protected on all four sides by
louvered panels.
Low ambient Cooling
As manufactured, this unit has a cool-
ing capability to 55°F. For low ambient
cooling below 55° see Application Guide
APP-APG013-EN.
Casing
Unit casing is constructed of heavy
gauge, G60 galvanized steel and
painted with a weather-resistant powder
paint on all louvers and panels. Cor-
rosion and weatherproof CMBP-G30
DuraTuff™ base.
Refrigerant Controls
Refrigeration system controls include
condenser fan, compressor contactor
and high pressure switch. High and low
pressure controls are inherent to the
compressor. A factory installed liquid line
drier is standard.
Compressor
The Climatuff® 2-stage compressor
features internal over temperature and
pressure protection and hermetic motor.
Other features include: roto lock suction
and discharge refrigerant connections,
centrifugal oil pump and modular plugs
for electrical connections.
22-1752-10
11
Download from Www.Somanuals.com. All Manuals Search And Download.
10/10
Trane has a policy of continuous product and product data improvement and it reserves the right to change
Trane
design and specifications without notice.
Download from Www.Somanuals.com. All Manuals Search And Download.
|