830S and 850S Series Rotary Sprinklers
Installation & Service Instructions
Introduction ______________________________________________________________________
The 830S and 850S series full-circle rotary sprinklers are designed
specifically for golf course applications.
Manufactured from durable, high-strength engineering plastic and
stainless-steel components, these sprinklers incorporate many innovative
and time-proven features for lasting, maintenance-free operation.
Prior to installing the sprinkler, read through the recommended installation
and start-up procedures. Please observe all WARNINGS and CAUTIONS
when installing and operating this equipment.
830S Electric Valve-In-Head
850S Electric Valve-In-Head
Features _______________________________________________________________________________
I Full 3" (7.6 cm) pop-up clears tall grasses
I Nozzles color-coded by radius and gallonage
I Cap serves as an effluent water indicator
I Variable stator
I Three body thread types available: NPT, BSP and ACME
I Manual control at the sprinkler, On-Off-Auto (Electric VIH only)
I Bowl-vented discharge (atmospheric) minimizes the
differential pressure required for regulation and ensures
positive valve closure (Electric VIH only)
I Standard pressure regulation settings of 50 psi (3.4 bar),
65 psi (4.5 bar), 80 psi (5.5 bar) or 100 PSI (6.9 bar) to
ensure consistently accurate nozzle performance
regardless of elevation
I All internal components serviceable from the top of the
sprinkler
I Large selection of color-coded nozzles available
I Durable plastic and stainless-steel construction
I Spike-GuardTM solenoid for superior surge protection
I Three body activation types available: Electric VIH,
Normally Open Hydraulic VIH, and Check-O-Matic
Specifications and Performance/Application Data _______________________________________
830S Series
850S Series
I
I
I
I
I
Radius: 55–89' (16.8–27.1 m)
Flow Rate: 13.6–45.3 GPM (51.4–171.5 l/mn)
Trajectory: 25°
Arc: Full Circle
Recommended Operating Pressure: 50–100 PSI
(3.5–6.9 Bar)
I
I
I
I
I
I
I
I
Radius: 55'–100' (16.7 m–30.4 m)
Flow Rate: 13.9–61.7 GPM (52.6–233.5 l/mn)
Trajectory: 25°
Arc: Full Circle
Recommended Operating Pressure: 50–100 PSI (3.5–6.9 Bar)
Minimum Pressure: 40 PSI (2.8 Bar)
Maximum Pressure: 150 PSI (10.3 Bar)
Precipitation Rate:
I
I
I
Minimum Pressure: 40 PSI (2.8 Bar)
Maximum Pressure: 150 PSI (10.3 Bar)
Precipitation Rate:
I
Minimum: 0.50"/hr (12.7 mm/hr)
Maximum: 0.72"/hr (18.3 mm/hr)
I
Minimum: 0.46"/hr (11.7 mm/hr)
I
I
Maximum: 0.63"/hr (16 mm/hr)
I
I
I
I
Body Height: 11" (27.9 cm)
Pop-Up Height: 3" (7.6 cm)
I
I
I
I
Body Height: 10" (25.4 cm)
Pop-Up Height: 3" (7.6 cm)
1.5" NPT, BSP or ACME Female Thread Inlet
1" NPT, BSP or ACME Female Thread Inlet
Spike GuardTM Solenoid:
Spike GuardTM Solenoid:
I
I
24 V a.c., 50/60 Hz
Inrush Current: 50 Hz, 0.17 Amps (4.1 VA)
60 Hz, 0.12 Amps (2.9 VA)
I
I
24 V a.c., 50/60 Hz
Inrush Current: 50 Hz, 0.17 Amps (4.1 VA)
60 Hz, 0.12 Amps (2.9 VA)
Holding Current: 50 Hz, 0.15 Amps (3.6 VA)
60 Hz, 0.10 Amps (2.4 VA)
I
Holding Current: 50 Hz, 0.15 Amps (3.6 VA)
60 Hz, 0.10 Amps (2.4 VA)
I
I
I
I
Manual Control (Electric VIH only): On-Off-Auto
Check-O-Matic model checks up to 37' (11.3 m) of elevation.
Nozzle Variations: See chart on page 2.
I
I
I
Manual Control (Electric VIH only): On-Off-Auto
Check-O-Matic model checks up to 37' (11.3 m) of elevation.
Nozzle Variations: See chart on page 2.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Procedure ___________________________________________________
To assure maximum performance from your 800S series sprinklers, read these instructions
completely prior to installation or service.
Figure 1
O
A
U
T
F
F
O
N
O
Constructing Swing Joints
1. Construct or provide triple swing joints for each sprinkler as shown in Figure 1. Use PVC or
ABS pipe nipple for the sprinkler connection.
Note: On sites where the possibility of heavy equipment rolling over a sprinkler exists, the
swing joint will flex preventing damage to the lateral or main lines. On a new installation in
raw ground where the sprinklers are to be initially installed above the finished grade and
lowered when new turf is established, the swing joint allows sprinkler repositioning without
changing risers. This is a common and practical procedure which eliminates the problem of
dirt being accidentally introduced into the lateral lines when a riser is changed.
2. Flush lines thoroughly prior to installing sprinkler.
3. Apply plumbing tape on riser threads (not required on ACME threads). Install sprinkler to riser and tighten.
CAUTION: Use only plumbing tape on riser threads. Use of pipe dope or other types of sealing compounds can cause
deterioration of sprinkler body threads.
Connecting Control Wires (Electric Models Only)
1. Route control wires to sprinklers. Provide extra wire at sprinkler to allow for height adjustment. One common wire and station
wire is required for each sprinkler. See Wire Sizing Chart, Table 1 for proper application.
Note: Wire length data provided in Table 1 is the sum of the station and common wire legs. See example in Figure 2.
Table 1: Wire Sizing Chart
Total Wire Length Between Controller and Sprinkler
1 Sprinkler 2 Sprinklers 3 Sprinklers 4 Sprinklers
Voltage Drop
Voltage AWG
mm2
2.5/2.5
2.5/4.0
Circular Mils
4100
23
23
23
23
23
23
23
24
24
24
24
24
24
24
4
4
4
4
4
4
4
5
5
5
5
5
5
5
6571'
8518'
2003 m 3285' 1001 m 2190' 668 m
2596 m 4259' 1298 m 2839' 865 m
1643'
2129'
14/14
14/12
501 m
649 m
886 m
798 m
1034 m
1406 m
5315
7250
6530
8465
11515
10400
4100
5315
7250
6530
8465
11515
10400
14/10 2.5/5.5
11619' 3541 m 5809' 1771 m 3873' 1180 m 2905'
10465' 3190 m 5232' 1595 m 3488' 1063 m 2616'
13566' 4135 m 6783' 2067 m 4522' 1378 m 3391'
1875 m
12/12
12/10
12/8
4.0/4.0
4.0/5.5
4.0/7.0
18454'
5625 m
9227'
2812 m 6151'
4613'
4167'
2053'
10/10 5.5/5.5
14/14
16667' 5080 m 8333' 2540 m 5556' 1693 m
8213'
1270 m
626 m
2503 m 4107' 1252 m 2738' 835 m
2.5/2.5
14/12 2.5/4.0
14/10
3245 m
2662'
812 m
10647'
5324' 1623 m 3549' 1082 m
4427 m
4841'
1107 m
997 m
1292 m
1758 m
1581 m
14523'
7262' 2213 m
1993 m
4360' 1329 m 3270'
1476 m 3631'
2.5/5.5
13081' 3987 m 6540'
16957' 5168 m 8479' 2584 m 5652' 1723 m
12/12 4.0/4.0
12/10 4.0/5.5
4239'
23067'
20833'
12/8
10/10 5.5/5.5
7031 m 11533' 3515 m 7689' 2344 m 5767'
4.0/5.5
10417'
6944'
5208'
6350 m
3175 m
2117 m
Figure 2
2. Attach control wires to solenoid leads using an
approved waterproof splicing method.
CAUTION: All wire splices and field
connections must be waterproofed to prevent
short circuit to ground and subsequent controller
damage.
Station Wire = 1095' (334m)
Common Wire = 1095' (334m)
Total Wire Length = 2190' (668m)
Connecting Hydraulic Control Tubing
1. Route control tubing from the controller to the
sprinkler location(s).
Note: Leave an 18" (45.7 cm) service loop of tubing
at each sprinkler to facilitate movement of sprinkler
and service operations. Refer to Table 2 for tubing
run length and sprinkler elevation information.
Table 2: Hydraulic Control Systems
Maximum Distance
Type of System*
From Controller
Elevation Restrictions
Normally Open (01)
Valve elevation should not exceed
25' ABOVE controller elevation or
70' BELOW controller elevation.
2. Flush tubing thoroughly to remove all air and debris.
with 3/16" Control Tubing
500'
3. Remove the tube retainer and poly cap from the
tubing adapter at the base of the sprinkler.
Normally Open (01)
Valve elevation should not exceed
25' ABOVE controller elevation or
70' BELOW controller elevation
with 1/4" Control Tubing
1000'
4. Slide the tube retainer over the end of the control
tubing and attach tubing to adapter.
- All hydraulic connections on Toro valves are 1⁄4" insert type.
- Control line pressure must be equal to or greater than mainline pressure.
- Control line pressure range is 40 to 150 PSI.
*
5. Slide tube retainer over adapter area to secure tubing.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
System Start Up _________________________________________________________
The following is a recommended procedure that will protect system components during system start-up. The procedure is based on a
velocity fill rate of less than 2' (.61 m) per second. See Table 3 below.
Table 3: Recommended System Fill Rate
Pipe Size
Flow
Velocity
Pipe Size
Flow
Velocity
in.
1/2
3/4
cm
1.3
1.9
2.5
3.1
3.8
5.0
6.4
GPM
2
3
LPM
7.6
ft/sec
m/sec
0.49
0.59
0.46
0.57
0.43
0.55
0.56
in.
3
4
6
8
cm
7.6
GPM
45
75
150
250
450
500
LPM
170.3
283.9
567.8
946.3
1703.0
1893.0
ft/sec
m/sec
0.57
0.57
0.53
0.52
0.60
0.47
1.60
1.92
1.50
1.86
1.41
1.80
1.84
1.86
1.87
1.73
1.70
1.97
1.55
11.4
18.9
37.9
37.9
75.7
113.6
10.1
15.2
20.2
25.4
30.5
1
5
1-1/4
1-1/2
2
10
10
20
30
10
12
2-1/2
WARNING
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED,
DURING MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE
PROCEDURES. DIRECT CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED
SPRINKLER CONNECTION OR SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER
PRESSURE CAN CAUSE SERIOUS INJURY.
1. Use a jockey pump only to fill the system at a velocity fill rate of less than 2' (0.61 m) per second.
CAUTION: Failure to comply with recommended fill rate will increase line pressure resulting in a water hammer
effect that could damage sprinklers and piping components. See Warning above.
2. At all tees and greens use quick coupler keys with quick coupler valves to bleed air from the system lines during the filling
process. For best results, do not compress air and then relieve it – bleed the air constantly while filling the system.
3. After water has filled all lines and all air is removed, remove the quick coupler keys.
Pilot Valve Operation (Electric Models Only) ________________________________________
The pilot valve controls the operation of the main valve located in the base of the sprinkler body. The main valve is operated by the release
of water metered through the pilot valve when it is activated either manually at the sprinkler or by the irrigation system controller.
The pilot valve regulates the water pressure to the sprinkler nozzle. Pressure regulation compensates for large variations within the
system and maintains a constant pressure for optimum sprinkler operation. The pilot valve is factory set to regulate one of four
pressure levels: 50 psi (3.4 bar), 65 psi (4.5 bar), 80 psi (5.5 bar) or 100 PSI (6.9 bar).
The sprinkler operation mode is set using a Toro Selector Tool (P/N 995-15) inserted through the body flange onto the pilot valve D-
shaped selector cam. The "AUTO" mode permits automatic operation from the system controller. The "ON" mode opens the main
valve for manual operation and "OFF" mode prevents the main valve from opening.
Troubleshooting _________________________________________________________
I
Pilot Valve
Possible equipment failures with causes and corrective action are listed below.
PROBLEM
POSSIBLE CAUSE – CORRECTIVE ACTION
SPRINKLER WILL
NOT TURN ON
(a) No 24 VAC to coil assembly. (Electric Models)
– Measure voltage with a Digital Volt Meter (DVM). Check wiring and controller program.
– Refer to Controller Operating Instructions.
(b) Selector cam in "OFF" position.
– Set to "AUTO" position.
(c) Debris in pilot valve assembly.
– Disassemble and remove all debris. (See Servicing Pilot Valve page 11.)
(d) Insufficient pressure in controller supply line and/or sprinkler control tube. (N.C. Models)
– Check pressure.
SPRINKLER WILL
NOT SHUT OFF
(a) Constant 24 VAC from controller. (Electric Models)
– Check for voltage using a DVM. If voltage is present, disconnect wire.
If sprinkler closes, service controller. Refer to Controller Service Manual.
(b) Selector cam in manual "ON" position.
– Set to "AUTO" or "OFF" position.
(c) Debris in pilot valve assembly.
– Disassemble and remove all debris. (See Servicing Pilot Valve page 11.)
(d) Constant pressure from controller. (N.C. Models)
– Check pilot valve at controller for constant flow.
– Check elevation differential. Valve elevation should not exceed 0' above
controller elevation or 70' (21.3 m) below controller elevation.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
I
Sprinkler Assembly
PROBLEM
POSSIBLE CAUSE – CORRECTIVE ACTION
SPRINKLER WON'T ROTATE
(a) Debris wedged between stator and turbine.
– Remove obstruction.
(b) Drive assembly defective.
– Replace drive assembly.
(c) Nozzle base assembly defective.
– Replace nozzle base assembly.
(a) Dirt in riser assembly.
HEAD STICKS UP
– Flush out. (See Flushing Procedure on page 11.)
(b) Damaged or missing return spring.
– Replace.
(c) Damaged riser.
– Replace.
POOR DISTRIBUTION PATTERN
(a) Nozzle plugged with debris.
– Clean or replace nozzle.
(b) Nozzle orifice damaged.
– Replace nozzle.
(c) Low operating pressure.
– Determine why system overloaded and correct.
I
Main Valve
PROBLEM
VALVE WON'T CLOSE
(Electric )
POSSIBLE CAUSE – CORRECTIVE ACTION
(a) Continuous 24 VAC to sprinkler.
– Check controller for voltage source.
(b) Leak in pilot valve assembly.
– Replace pilot valve assembly.
(c) Plugged supply screen on piston.
– Clean or replace screen.
(d) Manual control selector on pilot valve assembly turned to "ON" position.
– Turn to "AUTO" position.
(e) Plunger movement restricted.
– Inspect and clean or replace.
(f) Valve cylinder misaligned with sprinkler body communication tube.
– Remove valve assembly and install correctly.
(g) Foreign object keeping valve from seating.
– Remove, clean and check valve for damage. Replace if necessary.
(h) Damaged piston seal or piston assembly.
– Replace valve assembly.
VALVE WON'T CLOSE
(Hydraulic)
(a) Leak in control tubing.
– Isolate and repair.
(b) Pilot valve leak in controller.
– Confirm by observing constant dripping from discharge line of controller.
Refer to Controller Service Manual.
(c) Valve cylinder misaligned with sprinkler body communication tube.
– Remove valve assembly and install correctly.
(d) Foreign object keeping valve from seating.
– Remove, clean and check valve for damage. Replace if necessary.
(e) Damaged piston seal or piston assembly.
– Replace valve assembly.
VALVE WON'T OPEN
(Electric)
(a) Control (field) wires severed.
– Isolate and repair.
(b) No power to controller.
– Establish controller power.
(c) No power from controller to solenoid.
– Check for blown fuse and replace.
(d) Manual control selector on pilot valve assembly turned to "OFF" position.
– Turn to "AUTO" position.
(e) Pilot valve solenoid inoperative.
– Remove and replace.
(f) Pilot valve plunger movement restricted.
– Inspect, clean and/or replace.
(g) No supply from main valve.
– Debris in control tube, main valve assembly and/or communication passages in
body. Flush thoroughly.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
VALVE WON'T OPEN
(Hydraulic)
(a) Plugged controller discharge line or discharge port in pilot valve.
– Verify by checking for discharge at discharge line when station is
activated. If no discharge, refer to Controller Service Manual.
SPRINKLER WEEPING
(Slow leak in valve)
(a) Damaged or blocked valve seat.
– Remove blockage and, if necessary, replace valve assembly.
(b) Damaged piston seal or piston assembly.
– Replace valve assembly.
(c) Low pressure on supply line .
– Check for low pressure reason and correct.
(d) Elevation of normally closed sprinkler exceeds 75' (22.9 m) differential.
SEVERAL VALVES ON DIFFERENT (a) Control tubing leak which lowers supply pressure to other stations.
STATIONS FAIL TO CLOSE
(Hydraulic)
– Turn controller from station to station until a station is reached where
only valves on that station stay open. The leak would be in the tubing
on that station. Isolate and repair.
(b) Leak in supply line to controller.
– Verify by checking pressure in all control lines.
(c) Leak in controller pilot valve.
– Verify by constant discharge from controller.
(d) Plugged supply line filter.
– Replace filter if more than 3 psi (0.21 bar) differential exists.
Servicing Procedures ____________________________________________________
The 800S series sprinklers are designed to provide the user trouble-free operation for many years without scheduled maintenance. If
it becomes necessary to disassemble the sprinkler to correct a malfunction or replace a component, all internal parts of the sprinkler
can be accessed from the top. Refer to the Troubleshooting Procedure in this manual in the event of a malfunction. Some special
tools are required for disassembly and/or maintenance of the sprinkler and are available from your Toro dealer.
WARNING
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED,
DURING MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE
PROCEDURES. DIRECT CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED
SPRINKLER CONNECTION OR SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER
PRESSURE CAN CAUSE SERIOUS INJURY.
Servicing Sprinkler Mechanism
Note: Refer to Figure 3 for the following procedure.
Figure 3
1. Remove cap screw (1) and cap (3).
1
2
12
2. Insert hooked end of multi-purpose tool (P/N 995-83) into slot in snap
ring (8). Pull snap ring inward toward the sprinkler assembly, then
upward to remove from the snap ring groove in sprinkler body.
3
13
3. Insert hooked end of multi-purpose tool into slot over inner nozzle (7)
and pull riser assembly out of sprinkler body.
4
5
4. Grasp return spring (11) and riser (13) firmly and hold in place while
removing nozzle base (5). Turn nozzle base assembly counter-
clockwise to remove.
6
7
5. Carefully release tension from return spring.
6. Remove spring and seal retainer/o-ring assembly (9 and 10).
8
14
7. Remove rock screen (16) from bottom of riser assembly by turning it
counterclockwise with edge of multi-purpose tool or tips of snap ring
pliers (P/N 995-100).
9
10
8. Remove o-ring (12) from top of riser assembly.
15
9. Remove drive assembly (14) and stator (15) from riser assembly by
carefully pressing on end of threaded shaft.
16
10. Using a 5/8" nut driver (P/N 995-99), unscrew main nozzle (4) from
nozzle base assembly.
11. Using a 7/16" nut driver (P/N 995-79), unscrew two inner nozzles
(6 and 7) from nozzle base assembly.
11
12. Thoroughly clean and inspect all parts and replace as necessary.
Reassemble in the reverse order.
Note: During reassembly, ensure snap ring is correctly installed and
fully seated in snap ring groove.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Servicing Main Valve
WARNING
IF THE VALVE SNAP RING IS DIFFICULT TO REMOVE, RESIDUAL WATER PRESSURE MAY BE
REMAINING IN THE SYSTEM. TO PREVENT POSSIBLE SERIOUS INJURY DUE TO VALVE BEING
EJECTED UPWARD UNDER PRESSURE, CONFIRM THE FOLLOWING CONDITIONS EXIST PRIOR TO
REMOVING THE SNAP RING AND VALVE:
A. WATER SUPPLY TO SPRINKLER IS SHUT OFF AT SOURCE.
B. All PRESSURE IS BLED FROM SYSTEM, INCLUDING CONTROL TUBES.
C. AC POWER IS DISCONNECTED AT SOURCE.
1. See WARNING above. To remove valve assembly, squeeze
Figure 4
Figure 5
snap ring ears together with snap ring pliers (P/N 995-100) and
remove snap ring from sprinkler body. See Figure 4.
2. Use valve removal tool P/N 995-08 for 830S or 995-09 for 850S
to remove valve assembly from base of sprinkler body. Valve
removal tool is inserted into sprinkler body and pushed through
valve ribs. A slight twist will catch tool under ribs enabling valve
removal by pulling straight up and out. See Figure 5.
Note: If valve removal tool is not available, use snap ring pliers
to grasp rib of valve cylinder assembly and pull up and out of
sprinkler body.
3. Reinstall valve assembly using valve insertion tool P/N 995-76
for 830S or 995-101 for 850S as follows:
• Load snap ring on insertion tool carrier with stepped side
against carrier as shown in Figure 6. While holding snap ring in
compressed position, slide retainer clip in to hold snap ring ears
• Load valve assembly on carrier as shown.
• Locate position of communication tube in bottom of sprinkler body and orient insertion tool accordingly.
• Insert tool straight down into sprinkler body aligning bosses on t-handle with holes on sprinkler body flange. When valve
assembly clears vertical side wall ribs inside body, pull up on snap ring release mechanism (850S models only) and press valve
assembly into position. Snap ring will lock into groove when properly installed. Remove insertion tool and check snap ring to
confirm that it is fully seated in groove.
Figure 6
Snap Ring In
Retainer Clip
Snap Ring Release
Mechanism
Stepped Side
of Snap Ring
Valve Assembly
Orientation In Carrier
Valve Assembly
Pressed Into Position
Snap Ring
Released
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Servicing Pilot Valve
WARNING
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED,
DURING MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE
PROCEDURES. DIRECT CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED
SPRINKLER CONNECTION OR SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER
PRESSURE CAN CAUSE SERIOUS INJURY.
Note: Refer to Figure 7 for the following procedure.
1. Make sure that the water supply to sprinkler is
positively shut off and any residual pressure
has been bled off. If the sprinkler is
Figure 7
pressurized, main valve will open when the
pilot valve is disconnected from control tube.
6
2. Carefully remove turf and soil from side of
sprinkler to expose pilot valve and control
tubing.
10
7
3. Remove two retaining screws from the pilot
valve housing (1).
5
9
4. Pull the pilot valve assembly away from the
sprinkler body and cut the control tubing just
below tube retainer. Unless pilot valve has
been previously removed, control tubing
length will be sufficient for re-connection.
8
5. Remove tube retainer and remaining piece of
control tubing from valve body fitting.
4
2
8. Pull pilot valve body assembly out of
housing.
3
1
6. Remove solenoid (2) by turning it
counterclockwise.
7. Remove selector shaft assembly (8) and
plunger assembly (3). (The selector shaft
retains the plunger in the valve body.)
9. Remove diaphragm assembly (10), piston (9),
spring (8) and o-ring (4).
10. Thoroughly clean and inspect all parts. Replace damaged parts as necessary and reassemble in reverse order.
Note: Refer to Illustrated Parts Breakout Book, form number 368-0044 for part numbers.
Flushing Sprinkler _______________________________________________________
WARNING
NEVER STAND OR LEAN OVER THE SPRINKLER WHILE THE IRRIGATION SYSTEM IS BEING FILLED,
DURING MANUAL OR AUTOMATIC OPERATION OR WHEN PERFORMING SPRINKLER SERVICE
PROCEDURES. DIRECT CONTACT WITH IRRIGATION SPRAY, A FAILED OR IMPROPERLY INSTALLED
SPRINKLER CONNECTION OR SPRINKLER COMPONENTS FORCIBLY EJECTED UPWARD UNDER
PRESSURE CAN CAUSE SERIOUS INJURY.
1. With sprinkler operating, carefully step down on center of cap several times. Water will flow around riser and flush out debris.
2. Cycle sprinkler on and off several times to check for proper retraction. Cap should be even with top of body flange when fully
retracted. If riser sticks in up position, check for debris lodged between riser and body. Flush out all debris. Remove sprinkler
mechanism if necessary.
© 2002 The Toro Company, Irrigation Division
Form Number 373-0243 Rev. A
Download from Www.Somanuals.com. All Manuals Search And Download.
|