Telguard® Digital Model TG-9
Digital Cellular Alarm Communicator
Installation and Operating Instructions
Important: Read Before Installing Model TG-9
The following tools are required for installation:
Screwdriver and appropriate mounting screws
Confirm the presence of all required parts:
•
•
•
1x TG-9 Cellular Alarm Communicator
1x Dipole Antenna
6x End-Of-Line resistors
Before going to the site:
•
Fill out and submit the Telular TG-9 Digital Cellular Service Activation
Form.
•
Fax the activation form to 678-945-1651 or submit the activation form
on the internet at Telular.com
Note:
Ensure that you have the correct wiring diagram for the selected TG-9
Operation Profile.
Technical Support: 800-229-2326
M-F 8:00AM – 8:00PM EST
Saturday 9:00 AM – 5:00 PM EST
April 27, 2007
56037002
- 1 -
© 2007 Telular Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Instructions
WARNING! DO NOT MOUNT THE UNIT YET!
This unit is a cellular communications device.
THE ANTENNA MUST NOT BE INSTALLED IN THE BASEMENT!
1. Connect the power.
Connect the Telguard TG-9 to the 12v DC power output from the alarm panel or to a 9-15v
DC (250 mA minimum) power supply. Ensure that the LEDs come on.
Important: The 2.5mm port on the side of the TG-9 is for programming and
diagnostics only. It is not a power input and installer shall not insert
any type of jack or other device into this port.
2. Check the signal strength.
Look at LED 1 and compare it to the following chart.
Green Solid
Green Flashing
Yellow Flashing
Red
Good Signal Strength
Acceptable Signal Strength
Weak Signal Strength
No Signal Strength
If the light is not green flashing or green solid, move the unit or antenna around until a green
flashing or green solid is achieved.
3. Activate the unit.
Short Trip Input 6 (the bottom two terminals). LED 2 should go from RED to SOLID GREEN.
This indicates that the unit is registered and active. This may require up to 3 minutes.
Note: If using Bell input, Bell must be connected per Table 1 on page 5 before
activating. Make sure there are no Bell alarms in progress before activating.
If a FLASHING RED appears on LED 2, the unit has failed registration. This usually indicates
that the Activation Form has not been completed. If this occurs, call Telular Technical
Support at 800-229-2326.
4. Connect the trip inputs.
The trip inputs on the TG-9 should be connected according to the TG-9 Operation Profile
selected for the unit. (Consult the installation diagram on the opposite page.) All zone inputs
require an E.O.L. resistor (supplied).
Note: If zone 1 is programmed as a bell input, do not connect E.O.L. resistor.
5. Send test signals.
Trip zones on the system, and confirm that signals are received at the central station.
6. Connect the relay output to the alarm panel. (Optional)
The STC relay output is a Normally Closed (N.C.) contact. The zone on the panel should be
programmed as a 24-Hour Supervisory Zone.
7. Permanently mount the Telguard TG-9
56037002
- 3 -
© 2007 Telular Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
56037002
- 4 -
© 2007 Telular Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
LED Functions & Description
LED 1: Signal Strength
LED 2: Operating Mode
Green Solid
Green Flashing
Yellow Flashing
Red
Good Signal Strength
Green
Registered and Enabled
Acceptable Signal Strength
Weak Signal Strength
No Signal Strength
Green flash Transmitting Signal
Yellow
Red
Awaiting Response
Not Registered or Enabled
Red Flashing Failed Registration, NACK
LED 3: System Status
LED 3: STC LED Table
Green
All OK
One Flash, Pause
Four Flashes, Pause
Five Flashes, Pause
Power Failure
No Cellular Service
Fail To Communicate
Green Flashing
Yellow Flashing
Red Flashing
Red
FOTA in Progress
Standby Mode (Shunt)
STC
No SIM Card Installed
UL SUPPLEMENTAL LISTING:
The following programming and installation requirements must be met:
For commercial applications, the model TG9G0001 shall be secured inside the listed control
unit enclosure and only the antenna may protrude out of the enclosure. TNC jumper may be
used for mounting the antenna outside of the control unit.
For residential applications, the model TG9G0001 may be mounted in the same protected
room outside of the panel enclosure.
The TG-9 panel has been cross listed with the following panels. If connecting Telguard with a
cross listed panel please use the following chart for the wiring between the bell output of the
alarm panel and the Trip1 input of the Telguard.
TG-9 is for supplemental use only. For UL listed application, do not connect the trip input
zones 2 through 6.
Bell polarity
Model
Low = connect – to INPUT_1,
High = connect + to INPUT_1
Ademco Vista-20
Brinks B3000
GEM P1632
Bosch D7212GV2
DMP XR500
High
High
High
High
High
High
Low
Napco F-8KIT1
DSC5020
TABLE 1 – Zone 1 Bell Polarity
Note: the Telguard model TG-9 requires a minimum of 250ma during normal operating mode. Please
ensure you do not exceed the auxiliary current supply of the alarm panel.
56037002
- 5 -
© 2007 Telular Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
System Specifications
Digital Cellular Radio
The Telguard TG-9 radio supports GSM/GPRS cellular protocol. It is equipped with an integrated radio
transceiver conforming to all the requirements of the GSM Phase 2+ tests specified in GSM 11.10. The
TG-9 transceiver is FCC compliant, meeting all of the requirements of Part 24 and SAR testing. It is also
compliant to the PTCRB NAPRD03 requirements.
•
Frequency range: GSM 850/1900MHz,
1. 850: Tx = 824MHz-849MHz & Rx = 869MHz-894MHz
2. 1900: Tx = 1850MHz-1910MHz & Rx = 1930-1990MHz
•
•
•
Antenna Port: TNC connector (female), 50-ohm
Receiver Sensitivity: -102 dBm
Transmit Power:
EGSM 850MHz: Class 4 (2 watts)
GSM 1900MHz: Class 1 (1 watt)
•
•
•
•
•
•
FCC ID: O9EQ2426-SK
Supplied Antenna: Dipole
Physical Size: 5.9"H x 2.5"W x 1.5"D.
Weight: 7.3 oz
Operating Environment: 0° C to +49° C; 0 - 85% humidity (non-condensing).
FCC RF Exposure Information
•
THE EXTERNAL ANTENNAS USED FOR THIS RADIO MODULE MUST PROVIDE A
SEPERATION OF AT LEAST 8 INCHES (20 CENTIMETERS) FROM THE GENERAL
PUBLIC.
Power Requirements
•
9-15v DC Power Supply, min. 250mA
Current Consumption
•
•
25mA Standby
150mA Transmit
Warranty
Telular will repair or replace (our option) inoperative units for up to two years from date of manufacture.
This excludes damage due to lightning or installer error. Unauthorized modifications void this warranty.
Not responsible for incidental or consequential damages. Liability limited to price of unit. This is the
exclusive warranty and no other warranties will be honored, whether expressed or implied. An RMA must
be assigned by calling tech support 800-229-2326 before returning product to:
Telular Corporation
Attn: Repair Depot
1801 South Fulton Drive
Corinth, MS 38834
RMA number must be on outside of box or product will not be accepted.
General Accessories
ACD-12
ACD-35
ACD-50
ACD-100
HGD-0
12 feet of antenna cable and mounting bracket
35 feet of low loss high performance antenna cable and mounting bracket
50 feet of low loss high performance antenna cable and mounting bracket
100 feet of low loss high performance antenna cable and mounting bracket
High Gain Directional Antenna
56037002
- 6 -
© 2007 Telular Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
|