MANUAL ADDENDUM
ULTRA SENSITIVITY MODEL
M200EU
NO/NO2/NOx ANALYZER
(Addendum to M200E Manual PN 04410)
Teledyne Advanced Pollution Instrumentation
9480 Carroll Park Drive
San Diego, CA 92121-5201
USA
Toll-free Phone: 800-324-5190
Phone: 858-657-9800
Fax: 858-657-9816
Email: [email protected]
Website: http://www.teledyne-api.com/
05385 Rev C
Copyright 2009-2010
DCN 5731
Teledyne Advanced Pollution Instrumentation
14 May 2010
Download from Www.Somanuals.com. All Manuals Search And Download.
Ultra Sensitivity Model M200EU NO/NO2/NOx Analyzer
Addendum to M200E
TABLE OF CONTENTS
Pneumatics................................................................................................................. 4
TAPI 05385 Rev B (DCN5519)
PRINTED DOCUMENTS ARE UNCONTROLLED
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Ultra Sensitivity Model M200EU NO/NO2/NOx Analyzer
Addendum to M200E
1. OVERVIEW
The model M200EU is a close derivative of the Model 200E NOx Analyzer. The main
differences are as follows.
The M200EU is more sensitive at low NOx levels than a standard 200E. The
instrument has a user selectable full scale range of 0-5 PPB to 0-2000 PPB of
NOx.
The reaction cell is gold plated. In addition, there is a pre-reactor, which allows
the measurements of any hydrocarbon interferents in the sample stream.
The sample flow is about 1000 cc/min.
The M200EU is equipped with a high performance pump, capable of producing a
reaction cell pressure of less than 5 Inch Hg absolute.
In addition to the contents of this M200EU Addendum, you must use the M200E manual.
CAUTION!
The following procedures apply only to the External Zero Air Scrubber and NOT to the inline
exhaust scrubber cartridge that is part of the pump pack assembly.
NOTE
The M200EU has equivalency approval, and may be used
for EPA monitoring.
TAPI 05385 Rev B (DCN5519)
PRINTED DOCUMENTS ARE UNCONTROLLED
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Ultra Sensitivity Model M200EU NO/NO2/NOx Analyzer
Addendum to M200E
2. SPECIFICATIONS, AGENCY
APPROVALS, AND WARRANTY
Min/Max Range
Min: 0-5 ppb of Full Scale
(Physical Analog Output)
Max 0-2000 ppb of Full Scale
Measurement Units
Noise at Zero1
ppb, ug/m3 (user selectable Single, independent or auto ranges)
<25 ppt RMS
Noise at Span1
Lower Detectable Limit1
<0.25% RMS of reading above 50 ppb
50 ppt RMS
<0.1 ppb / 24 hours
<0.2 ppb / 7 days
Zero Drift2
Span Drift2
<0.5% of reading or 50 ppt RMS whichever is greater / 24 hrs
<1% of reading or 100 ppt RMS whichever is greater / 7 days
Linearity
1% of full scale or 0.1 ppb whichever is greater
0.5% of reading above 50 ppb
20 sec
Precision
Lag Time1
Rise / Fall Time1, 3
95% in <50 sec
Sample Flow Rate
1000 cc/min. ± 10%
20-30oC within drift and noise specifications, and operating with EPA equivalency
5-35oC safe operating range
Temperature Range
Humidity
0-95% RH non-condensing
Propylene rejection ratio > 20,000:1
Ethylene rejection ratio > 40,000:1
Hydrocarbon Interference
Voltage Coefficient
Dimensions H x W x D
Weight, Analyzer
Weight, Ext Pump Pack
Power, Analyzer
Power, Analyzer4
Power, Ext Pump
Power, Ext Pump4
Analog Outputs
< 0.1% per V
7" x 17" x 23.5" (178mm x 432 mm x 597 mm)
18 kg (40 lbs)
9.5 kg (21 lbs)
100V~ 50/60 Hz, 120V~ 60 Hz, 230V~ 50 Hz, 2.5A, 125 watts
230V~ 50 Hz, 2.5A
110V~ 60 Hz, 220V~ 50 Hz, 240V~ 50Hz, 150 watts
230V~ 50 Hz, 2.2A
Four (4) Outputs
All outputs: 100 mV, 1, 5, 10V
Analog Output Ranges
Three outputs convertible to 4-20 mA isolated current loop
All ranges with 5% under/over range
Analog Output Resolution
Status Outputs
1 part in 4096 of selected full-scale voltage
8 Status Outputs from opto-isolators, 7 defined, 1 spare
6 Control Inputs, 4 defined, 2 spare
Control Inputs
2
TAPI 05385 Rev B
PRINTED DOCUMENTS ARE UNCONTROLLED
Download from Www.Somanuals.com. All Manuals Search And Download.
Ultra Sensitivity Model M200EU NO/NO2/NOx Analyzer
Addendum to M200E
COM 1: RS-232;
Serial I/O
COM 2: RS-232 or RS-485 (Ethernet interface available)
Baud Rate: 300-115200
Environmental4
Certifications
Installation Category (Over-voltage Category) II, Pollution Degree 2
US EPA: Reference Method Number RFNA 1194-099
CE: EN61326 (1997 w/A1:98) Class A, FCC Part 15 Subpart B Section 15.107 Class
A, ICES-003 Class A (ANSI C63.4 1992) & AS/NZS 3548 (w/A1 &A2;97) Class A
(1)
As defined by the USEPA
(2)
At constant temperature and voltage
With adaptive filter, > 20 ppb change
Electrical rating for CE mark compliance
(3)
(4)
TAPI 05385 Rev B (DCN5519)
PRINTED DOCUMENTS ARE UNCONTROLLED
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Ultra Sensitivity Model M200EU NO/NO2/NOx Analyzer
Addendum to M200E
3. PNEUMATICS
Refer to the following pneumatic diagram. It shows the internal pneumatics of the
M200EU in its standard configuration, along with the optional Zero/Span valves. The
sample flow is about 1000 cc/min. Also during Auto Zero mode, the sample gas is routed
through a pre-reactor before the mixture goes through the reaction cell. Since the reaction
rate constant between NO and ozone is several time faster than the reaction rate constant
between hydrocarbons and ozone, this mechanism helps to eliminate the interference
effects of hydrocarbons in NOx measurements. In addition, the M200EU is equipped
with a high performance pump, capable of producing a reaction cell pressure of less than
5 Inch Hg absolute.
Figure 3-1: Pneumatic Diagram With Zero/Span Option
4
TAPI 05385 Rev B
PRINTED DOCUMENTS ARE UNCONTROLLED
Download from Www.Somanuals.com. All Manuals Search And Download.
Ultra Sensitivity Model M200EU NO/NO2/NOx Analyzer
Addendum to M200E
4. SPARE PARTS LIST
Note: Only parts different from M200E are listed below. Refer to the M200E users
manual for the common spare parts.
Part Number
011340800
024600100
011420700
011440200
041800600
001270001
001330001
001350001
014080200
022880000
Description
Assy, Sensor, M200EU
Assy, Prereactor NO/NOx valve, M200EU
Assy, NOx cell, Gold plated, M200EU
Assy, PMT, M200AU/EU
PCA, PMT Preamp, VR, M200EU
Manifold, Gold Plated, NOx
Sleeve, Gold Plated, NOx
Nozzle, Outer, Gold Plated
Assy, HVPS, M200AU/EU
Assy, HVPS, Low Leak Current, M100EU/M200EU
TAPI 05385 Rev B (DCN5519)
PRINTED DOCUMENTS ARE UNCONTROLLED
5
Download from Www.Somanuals.com. All Manuals Search And Download.
|