Taylor Refrigerator model 430 torque shake slush freezer User Manual |
OPERATOR'S
MANUAL
Model 430 Torque
Shake/Slush Freezer
Original Operating Instructions
051430-M
3/97 Original Publication
(Updated 9/2/14)
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Section 1
To the Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
Installer Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air Cooled Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electrical Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Beater Rotation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Refrigerant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1
1
2
2
3
3
Section 2
To the Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operator Parts Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4
5
7
Section 3
Section 4
Section 5
Important: To the Operator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Viscosity Adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Power Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Reset Button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Indicator Light - “Mix Low” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Indicator Light - “Mix Out” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Section 6
Operating Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Sanitizing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Priming . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Closing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Draining Product From The Freezing Cylinder . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Rinsing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Disassembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Brush Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Table of Contents
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents - Page 2
______________________________________________________________________________
Section 7
Important: Operator Checklist . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
During Cleaning and Sanitizing: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Troubleshooting Bacterial Count: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Regular Maintenance Checks: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Winter Storage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Section 8
Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Parts Replacement Schedule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Limited Warranty on Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Limited Warranty on Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Section 9
Section 10
Section 11
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Note: Continuing research results in steady improvements; therefore, information
in this manual is subject to change without notice.
Note: Only instructions originating from the factory or its authorized translation
representative(s) are considered to be the original set of instructions.
E 1997 Carrier Commercial Refrigeration, Inc. (Original Publication)
(Updated September, 2014)
051430- M
Any unauthorized reproduction, disclosure, or distribution of copies by any person of any portion of this work
may be a violation of Copyright Law of the United States of America and other countries, could result in the
awarding of Statutory Damages of up to $250,000 (17 USC 504) for infringement, and may result in further
civil and criminal penalties. All rights reserved.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL 61072
Table of Contents
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 1
To the Installer
The following information has been included in the
manual as safety and regulatory guidelines. For
complete installation instructions, please see the
Installation Checklist.
This unit has many sharp edges that can
cause severe injuries.
Installer Safety
Site Preparation
In all areas of the world, equipment should be
installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Review the area where the unit will be installed before
uncrating the unit. Make sure all possible hazards to
the user or the equipment have been addressed.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor equipment.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of
70_-75_F (21_-24_C). The freezer has successfully
performed in high ambient temperatures of
104_(40_C) at reduced capacities.
S
Only authorized Taylor service personnel
should perform installation and repairs on the
equipment.
S
Authorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the
This unit must NOT be installed in an area
where a water jet or hose can be used. NEVER use a
water jet or hose to rinse or clean the unit. Failure to
follow this instruction may result in electrocution.
industry
standards
on lockout/tagout
procedures before beginning any installation
or repairs.
Authorized service personnel must ensure
that the proper PPE is available and worn
when required during installation and service.
Authorized service personnel must remove all
metal jewelry, rings, and watches before
working on electrical equipment.
S
S
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care should be
taken in moving this equipment for any reason. Two or
more persons are required to safely move this unit.
Failure to comply may result in personal injury or
equipment damage.
The main power supply(s) to the freezer must
be disconnected prior to performing any repairs.
Failure to follow this instruction may result in personal
injury or death from electrical shock or hazardous
moving parts as well as poor performance or damage
to the equipment.
The authorized installer should inspect the unit for
damage and promptly report any damage to the local
authorized Taylor distributor.
Note: All repairs must be performed by an
authorized Taylor Service Technician.
This unit is made using USA sizes of hardware. All
metric conversions are approximate and vary in size.
131202
1
Model 430 Torque
To the Installer
Download from Www.Somanuals.com. All Manuals Search And Download.
Each unit requires one power supply for each data
label on the unit. Check the data label(s) on the freezer
for branch circuit overcurrent protection or fuse, circuit
ampacity, and other electrical specifications. Refer to
the wiring diagram provided inside of the electrical box
for proper power connections.
Air Cooled Units
DO NOT obstruct air intake and discharge openings:
Air cooled units require a minimum of 3” (76.2 mm) of
clearance around all sides of the freezer to allow for
adequate air flow across condenser. Failure to allow
adequate clearance can reduce the refrigeration
capacity of the freezer and possibly cause permanent
damage to the compressor.
CAUTION: THIS EQUIPMENT MUST BE
PROPERLY GROUNDED! FAILURE TO DO SO
CAN RESULT IN SEVERE PERSONAL INJURY
FROM ELECTRICAL SHOCK!
Electrical Connections
This equipment is supplied with a 3- wire cord and
grounding type plug, for connection to a single phase,
60 cycle, branch circuit supply. This unit must be
plugged into a properly grounded receptacle. The cord
and plug provided are 20A for 115/60/1 or 15A for
208- 230/60/1; therefore, the wall outlet must also be
20A for 115/60/1 or 15A for 208- 230/60/1. Check the
data label, located on the side panel, for electrical
specifications. Permanent wiring may be employed, if
required by local codes. Instructions for conversion to
permanent wiring are as follows:
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment’s frame.
1. Be sure the freezer is electrically disconnected.
2. Remove the appropriate panel and locate the
small electrical box at the base of the freezer.
S
S
Stationary appliances which are not equipped
with a power cord and a plug or another device
to disconnect the appliance from the power
source must have an all-pole disconnecting
device with a contact gap of at least 3 mm
installed in the external installation.
3. Remove the factory installed cord and strain
relief bushing.
4. Route incoming permanent wiring through 7/8”
(22 mm) hole in base pan.
Appliances that are permanently connected to
fixed wiring and for which leakage currents
may exceed 10 mA, particularly when
disconnected, not used for long periods, or
during initial installation, shall have protective
devices such as a GFI to protect against the
leakage of current, installed by authorized
personnel to the local codes.
5. Connect two power supply leads. Attach ground
(earth) wire to the grounding lug inside the
electrical box.
6. Be sure unit is properly grounded before
applying power.
In the United States, this equipment is intended to be
installed in accordance with the National Electrical
Code (NEC), ANSI/NFPA 70-1987. The purpose of the
NEC code is the practical safeguarding of persons and
property from hazards arising from the use of
electricity. This code contains provisions considered
necessary for safety. In all other areas of the world,
equipment should be installed in accordance with the
existing local codes. Please contact your local
authorities.
S
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable, not
lighter than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(Code designation 60245 IEC 57) installed
with the proper cord anchorage to relieve
conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
If the supply cord is damaged, it must be
replaced by an authorized Taylor service
technician in order to avoid a hazard.
FOLLOW YOUR LOCAL ELECTRICAL CODES!
130930
2
To the Installer
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
Beater Rotation
Refrigerant liquid sprayed onto the skin may
cause serious damage to tissue. Keep eyes and skin
protected. If refrigerant burns should occur, flush
immediately with cold water. If burns are severe, apply
ice packs and contact a physician immediately.
Beater rotation must be clockwise as viewed
looking into the freezing cylinder.
Note: The following procedure must be
performed by an authorized Taylor service
technician.
To correct rotation on a single- phase unit, change the
leads inside the beater motor. (Follow the diagram
printed on motor.)
Taylor reminds technicians to be cautious of
government laws regarding refrigerant recovery,
recycling, and reclaiming systems. If you have any
questions regarding these laws, please contact the
factory Service Department.
Refrigerant
In consideration of our environment, Taylor
uses only earth friendly HFC refrigerants. The HFC
refrigerant used in this unit is R404A. This refrigerant
is generally considered non-toxic and non-flammable,
with an Ozone Depleting Potential (ODP) of zero (0).
However, any gas under pressure is potentially
hazardous and must be handled with caution.
WARNING: R404A refrigerant used in
conjunction with polyolester oils is extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
NEVER fill any refrigerant cylinder completely with
liquid. Filling the cylinder to approximately 80% will
allow for normal expansion.
Use only R404A refrigerant that conforms to
the AHRI standard 700 specification. The use of any
other refrigerant may expose users and operators to
unexpected safety hazards.
130816
3
Model 430 Torque
To the Installer
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 2
To the Operator
The freezer you have purchased has been carefully
engineered and manufactured to give you dependable
operation. The Taylor Model 430 Torque, when
properly operated and cared for, will produce a
consistent quality product. Like all mechanical
products, they will require cleaning and maintenance.
A minimum amount of care and attention is necessary
if the operating procedures outlined in this manual are
followed closely.
The user is responsible for returning the product to the
appropriate collection facility, as specified by your local
code. For additional information regarding applicable
local laws, please contact the municipal facility and/or
local distributor.
Compressor Warranty Disclaimer
The refrigeration compressor(s) on this unit are
warranted for the term stated in the Limited Warranty
section in this manual. However, due to the Montreal
Protocol and the U.S. Clean Air Act Amendments of
1990, many new refrigerants are being tested and
developed, thus seeking their way into the service
industry. Some of these new refrigerants are being
advertised as drop- in replacements for numerous
applications. It should be noted that in the event of
ordinary service to this unit’s refrigeration system,
only the refrigerant specified on the affixed data
label should be used. The unauthorized use of
alternate refrigerants will void your Taylor compressor
warranty. It is the unit owner’s responsibility to make
this fact known to any technician he employs.
This Operator’s Manual should be read before
operating or performing any maintenance on your
equipment.
Your Taylor freezer will NOT eventually compensate
for and correct any errors during the set- up or filling
operations. Thus, the initial assembly and priming
procedures are of extreme importance. It is strongly
recommended that personnel responsible for the
equipment’s operation, both assembly and
disassembly, sit down together and go through these
procedures in order to be properly trained and to make
sure that no misunderstandings exist.
In the event you should require technical assistance,
please contact your local authorized Taylor Distributor.
It should also be noted that Taylor does not warrant the
refrigerant used in its equipment. For example, if the
refrigerant is lost during the course of ordinary service
to this unit, Taylor has no obligation to either supply or
provide replacement refrigerant either at billable or
unbillable terms. Taylor will recommend a suitable
replacement if the original refrigerant is banned,
obsoleted, or no longer available during the five (5)
year Taylor warranty of the compressor.
Note: Your Taylor warranty is valid only if the parts are
authorized Taylor parts, purchased from the local
authorized Taylor Distributor, and only if all required
service work is provided by an authorized Taylor
service technician. Taylor reserves the right to deny
warranty claims on units or parts if non- Taylor
approved parts or incorrect refrigerant were installed
in the unit, system modifications were performed
beyond factory recommendations, or it is determined
that the failure was caused by abuse, misuse, neglect,
or failure to follow all operating instructions. For full
details of your Taylor Warranty, please see the Limited
Warranty section in this manual.
From time- to- time Taylor may test new refrigerant
alternates. Should a new refrigerant alternate prove,
through Taylor’s testing, that it would be accepted as
a drop- in replacement for this unit, then the disclaimer
in this “Compressor Warranty Disclaimer” section will
not apply to the use of the alternate refrigerant
approved by Taylor.
Note: Constant research results in steady
improvements; therefore, information in this
manual is subject to change without notice.
To find out the current status of an alternate refrigerant
as it relates to your compressor warranty, call Taylor or
your local authorized Taylor distributor. Be prepared to
provide the Model/Serial Number of the unit in
question.
If the crossed out wheeled bin symbol is
affixed to this product, it signifies that this product is
compliant with the EU Directive as well as other similar
legislation in effect after August 13, 2005. Therefore,
it must be collected separately after its use is
completed, and cannot be disposed as unsorted
municipal waste.
Note: Continuing research results in steady
improvements; therefore, information in this Operator
Manual is subject to change without notice.
131202
4
To the Operator
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 3
Safety
We, at Taylor Company, are concerned about the
safety of the operator at all times when they are
coming in contact with the unit and its parts. Taylor
makes every effort to design and manufacture built- in
safety features to protect both operators and service
technicians.
S
S
S
S
DO NOT operate the freezer unless it is
properly grounded.
DO NOT operate the freezer with larger fuses
than specified on the freezer data label.
Installing and servicing refrigeration equipment can be
hazardous due to system pressure and electrical
components. Only trained and qualified service
personnel should install, repair, or service refrigeration
equipment. When working on refrigeration equipment,
observe precautions noted in the literature, tags and
labels attached to the unit, and other safety
precautions that may apply. Follow all safety code
requirements. Wear safety glasses and work gloves.
All repairs must be performed by an
authorized Taylor service technician.
The main power supplies to the machine must
be disconnected prior to performing any
repairs.
For Cord Connected Units: Only Taylor
authorized service technicians or licensed
electricians may install a plug or replacement
cord on these units.
S
S
Stationary appliances which are not equipped
with a power cord and a plug or another device
to disconnect the appliance from the power
source must have an all-pole disconnecting
device with a contact gap of at least 3 mm
installed in the external installation.
Appliances that are permanently connected to
fixed wiring and for which leakage currents
may exceed 10 mA, particularly when
disconnected, not used for long periods, or
during initial installation, shall have protective
devices such as a GFI to protect against the
leakage of current, installed by authorized
personnel to the local codes.
Supply cords used with this unit shall be
oil-resistant, sheathed flexible cable, not
lighter than ordinary polychloroprene or other
equivalent synthetic elastomer-sheathed cord
(Code designation 60245 IEC 57) installed
with the proper cord anchorage to relieve
conductors from strain, including twisting, at
the terminals and protect the insulation of the
conductors from abrasion.
IMPORTANT - Failure to adhere to the
following safety precautions may result in severe
personal injury or death. Failure to comply with
these warnings may damage the machine and its
components. Component damage will result in
part replacement expense and service repair
expense.
S
DO NOT operate the freezer without reading
this Operator Manual. Failure to follow this instruction
may result in equipment damage, poor freezer
performance, health hazards, or personal injury.
S
This appliance is to be used only by trained
personnel. It is not intended for use by children or
people with reduced physical, sensory, or mental
capabilities, or lack of experience and knowledge,
unless given supervision or instruction concerning the
use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that
they do not play with the appliance.
If the supply cord is damaged, it must be
replaced by an authorized Taylor service
technician in order to avoid a hazard.
DO NOT use a water jet to clean or rinse the
freezer. Failure to follow these instructions may result
in serious electrical shock.
Failure to follow these instructions may result in
electrocution. Contact your local authorized Taylor
Distributor for service.
130930
Safety
5
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
This unit is provided with an equipotential
grounding lug that is to be properly attached to the rear
of the frame by the authorized installer. The installation
location is marked by the equipotential bonding
symbol (5021 of IEC 60417-1) on both the removable
panel and the equipment’s frame.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to the
cleaning section of this manual for the proper
procedure to clean this unit.
This machine is designed to maintain product
temperature under 41_F (5_C). Any product being
added to this machine must be below 41_F (5_C).
Failure to follow this instruction may result in health
hazards and poor freezer performance.
S
S
DO NOT allow untrained personnel to operate
this machine.
DO NOT operate the freezer unless all service
panels and access doors are restrained with
screws.
S
DO NOT remove any internal operating parts
(examples: freezer door, beater, scraper
blades, etc.) unless all control switches are in
the OFF position.
DO NOT obstruct air intake and discharge openings:
Failure to follow these instructions may result in severe
personal injury to fingers or hands from hazardous
moving parts.
Air cooled units require a minimum of 3” (76.2 mm) of
clearance around all sides of the freezer to allow for
adequate air flow across condenser. Failure to allow
adequate clearance can reduce the refrigeration
capacity of the freezer and possibly cause permanent
damage to the compressor.
This unit has many sharp edges that can
cause severe injuries.
S
DO NOT put objects or fingers in the door
spout. This may contaminate the product and
cause severe personal injury from blade
contact.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of 70_ -
75_F (21_ - 24_C). The freezer has successfully
performed in high ambient temperatures of
104_(40_C) at reduced capacities.
S
USE EXTREME CAUTION when removing
the beater asssembly. The scraper blades are
very sharp.
DO NOT run the unit without product. Failure to follow
this instruction can result in damage to the unit.
This freezer must be placed on a level
surface. Failure to comply may result in personal injury
or equipment damage.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the machine and at a height
of 1.6 meters from the floor.
Access to the service area of the unit must be
restricted to persons having knowledge and practical
experience with the unit, in particular as far as safety
and hygiene are concerned.
130930
Safety
6
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 4
Operator Parts Identification
9
8
10
7
12
6
5
11
AUTO
OFF
WASH
1
2
3
4
Item
Description
Part Number
Item
Description
Part Number
1
2
3
4
5
6
Shield- Splash
049320
049319
027504
049420
X50678
013496
7
8
Panel- Side Left
049639
Tray- Drip
Tube- Feed 13/32 Hole
Cover A.- Black Insulated
Panel- Back
025663- 10
X49679- BLA
049325
Pan- Drip 17- 1/4” Long
Gasket- Base Pan
Panel A.- Front
Stud- Nose Cone
9
10
11
12
Panel- Side Right
049640
Washer- Freezer Stud
049032
070104
7
Model 430 Torque
Operator Parts Identification
Download from Www.Somanuals.com. All Manuals Search And Download.
Item
Description
Part Number
Item
Description
Part Number
*1
2
Door A.- Partial
X39248- SER
X47384
047734
X25929
032504
047735
018550
X50382
014496
014030
11
12
13
14
15
16
17
18
19
Bearing- Front
013116
X49490
046237
046238
035418
032560
025307
025660
029880
Handle A.- Draw
Beater A.- 4 Qt. 1 Pin Support
Blade- Scraper- Plastic
Clip- Scraper Blade
Shaft- Beater
3
Valve- Draw
4
Valve A.- Handle Pin
O- Ring - 1” OD x .139 W
Buster- Ice
5
6
Seal- Drive Shaft
O- Ring 7/8 OD x .139 W
Arm- Torque
7
O- Ring - .291 ID x .080 W
Torque Assembly
8
9
Bearing- Guide
Nut- Stud
10
Gasket- Door 5.109” ID x 5.630
*IMPORTANT! Model 430 units equipped with prime
plug doors order: Door A.- Partial- Prime X50403- SER,
Plug- Prime 050405 & O- Ring 043758 (Not Shown)
130816
Operator Parts IdentificatiDoonwnload from Www.Somanuals.com. All Manuals Search And Download.
8
Model 430 Torque
Item
Description
Part Number
Item
Description
Part Number
1
2
3
Brush- 3” x 7” White
Brush- Double Ended
Brush- Draw Valve
023316
013072
014753
4
5
Brush- Rear Bearing
Lubricant- Taylor
013071
047518
*6
Video- Training M430Torque
050987- DVD
*Not Shown.
140102
9
Model 430 Torque
Operator Parts Identification
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 5
Important: To the Operator
Viscosity Adjustment
Reset Button
The viscosity (thickness) of the slush can be adjusted
by turning the viscosity adjustment screw on the upper
right side of the front panel. Turn the viscosity
adjustment screw clockwise for a thicker product, or
counterclockwise for a thinner product. After making
an adjustment, allow the refrigeration system to cycle
2 or 3 times to accurately evaluate the viscosity.
The reset button is located in the rear panel. The reset
protects the beater motor from an overload condition.
If an overload occurs, the reset mechanism will trip. To
properly reset the freezer, place the power switch in
the “OFF” position. Press the reset button firmly. Place
the power switch in the “WASH” position and observe
the freezer’s performance. Once satisfied, place the
control switch in the “AUTO” position.
Figure 1
Figure 3
IMPORTANT: Do not use metal objects to press the
reset button.
Power Switch
The center position is “OFF”. The “up” position is
“AUTO”, which activates the beater motor and the
refrigeration system. The “down” position is “WASH”,
which activates the beater motor only.
Indicator Light - “Mix Low”
A mix level indicating light is located on the front of the
machine. When the light is flashing, it indicates that the
mix hopper has a low supply of product and should be
refilled as soon as possible.
Indicator Light - “Mix Out”
A mix out indicating light is located on the front of the
machine. When the light is flashing, it indicates that the
hopper is empty and the mix supply needs
replenishing. To prevent damage to the unit,
refrigeration discontinues automatically when the mix
out indicator lights.
Figure 2
10
Important: To the OperatoDrownload from Www.Somanuals.com. All Manuals Search And Download.
Model 430 Torque
Section 6
Operating Procedures
The Model 430 freezer is designed to produce shake
or slush product at the desired thickness. This unit has
a 4 quart freezing cylinder.
Insert the beater drive shaft into the rear shell bearing
and engage the square end firmly into the female
socket of the drive unit. Be certain that the drive shaft
fits into the drive coupling without binding.
We begin our instructions at the point where we enter
the store in the morning and find the parts
disassembled and laid out to air dry from the previous
night’s brush cleaning.
These opening procedures will show you how to
assemble these parts into the freezer, sanitize them,
and prime the freezer with fresh mix in preparation to
serve your first portion.
If you are disassembling the machine for the first time
or need information to get to this point in our
instructions, turn to page 17, “Disassembly”, and start
there.
Assembly
Figure 5
Note: When lubricating parts, use an approved food
grade lubricant (example: Taylor Lube).
Step 1
Step 2
Lubricate both grooves on the drive shaft and slide the
o- ring in place. Lubricate the o- ring and shaft portion
that comes in contact with the bearing. DO NOT
lubricate the square end of the drive shaft. Lubricate
the boot seal groove and slide the boot seal over the
shaft and groove until it snaps into place. Fill the inside
portion of the seal with 1/4” more lubricant and evenly
lubricate the end of the seal that fits onto the rear shell
bearing. Install the drive shaft.
Install the beater assembly. First check the scraper
blade for any nicks or signs of wear. If any nicks are
present, replace the blade. If the blade is in good
condition, place the clip over the blade and install the
blade and clip on the beater assembly. Be sure the
holes in the blade and the clip are securely positioned
over the beater pin.
Figure 4
Note: Do not install the boot seal inside out.
Figure 6
11
Model 430 Torque
Operating Procedures
Download from Www.Somanuals.com. All Manuals Search And Download.
Holding the beater securely, slide the beater into the
freezing cylinder and align the hole at the rear of the
beater with the flats on the end of the drive shaft.
Slide the beater the remainder of the way into the
freezing cylinder and over the end of the drive shaft.
The beater assembly will not protrude beyond the front
of the freezing cylinder.
Figure 9
Step 5
Assemble the freezer door with the “Ice Buster” (door
spout clearing device). To assemble the door with the
ice buster, install the o- rings on the draw valve and
lubricate.
Figure 7
Step 3
Install the white plastic guide bearing on the short end
of the torque rotor. Slide the o- ring into the groove on
the long end of the torque rotor and lubricate the
o- ring. Do not lubricate the guide bearing.
Figure 10
Insert the draw valve into the door, leaving
approximately 1/2” of the valve sticking out the top of
the door.
Figure 8
Step 4
Insert the torque rotor end with the guide bearing into
the pilot hole in the center of the drive shaft. The hole
in the torque rotor shaft should be rotated to the 12
o’clock position.
Figure 11
12
Operating Procedures
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
Rotate the draw valve so the flats on the top of thedraw
valve are perpendicular to the door face.
Place the large rubber gasket into the groove on the
back side of the freezer door. Slide the white, plastic
front bearing onto the bearing hub, making certain that
the flanged end of the bearing is resting against the
freezer door. DO NOT lubricate the door gasket or
front bearing.
Figure 12
Insert the ice buster through the door spout and into
the slot located just above the lower o- ring.
Figure 15
Step 6
Position the torque arm by inserting it through the slot
in the torque switch arm and down into the hole in the
torque rotor which protrudes from the door. Verify
proper installation by moving the torque rotor back and
forth to be sure it moves freely and easily.
Figure 13
With the ice buster in place, rotate the draw valve to
allow installation of the draw handle. This will lock the
ice buster in place. Install the draw handle pin, and
close the draw valve by moving the handle to the left.
Figure 16
Figure 14
13
Model 430 Torque
Operating Procedures
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 7
Sanitizing
Install the front drip pan. Slide the long drip pan into the
hole in the front panel.
Step 1
Prepare a pail of an approved 100 PPM sanitizing
solution (examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R
or 2 gal. [7.6 liters] of Stera- SheenR). USE WARM
WATER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS.
Step 2
Pour the sanitizing solution into the hopper and allow
it to flow into the freezing cylinder.
Figure 17
Step 8
Install the front drip tray and splash shield beneath the
door spout.
Figure 20
Step 3
While the solution is flowing into the freezing cylinder,
brush clean the mix hopper, air/mix feed tube
(optional) and mix inlet hole.
Step 4
Figure 18
Place the power switch in the “WASH” position. This
will agitate the sanitizing solution in the freezing
cylinder. Allow the solution to agitate for five minutes.
Step 9
Lay the air/mix feed tube (optional) in the bottom of the
mix hopper.
Figure 19
Figure 21
090114
14
Operating Procedures
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 5
Priming
Place an empty pail beneath the door spout and move
the draw handle to the right. Draw off all the sanitizing
solution. When the sanitizer stops flowing from the
door spout, move the draw handle to the left and place
the control switch in the “OFF” position.
Step 1
With a pail beneath the door spout, move the draw
handle to the right. Pour two gallons (7.6 liters) of
FRESH mix into the hopper and allow it to flow into the
freezing cylinder. This will force out any remaining
sanitizing solution. When full strength mix is flowing
from the door spout, move the draw handle to the left.
Step 2
When the mix has stopped bubbling down into the
freezing cylinder, install the air/mix feed tube (optional)
in the mix inlet hole with the hole side down.
Figure 22
Step 6
Stand the air/mix feed tube (optional) in the corner of
the hopper.
Figure 24
Step 3
Place the power switch in the “AUTO” position. When
the unit cycles off, the product will be at serving
viscosity. The viscosity (thickness) of the slush can be
adjusted by turning the viscosity adjustment screw on
the upper right of the front panel. Turn the viscosity
adjustment screw clockwise for a thicker product, or
counterclockwise for a thinner product. After making
an adjustment, allow the refrigeration system to cycle
2 or 3 times to accurately evaluate the viscosity.
Figure 23
Figure 25
140804
15
Model 430 Torque
Operating Procedures
Download from Www.Somanuals.com. All Manuals Search And Download.
Step 4
Note: If local health codes DO NOT permit the use
of rerun, the product must be discarded. Follow the
instructions in the previous step, except drain the
product into a pail and properly discard the mix.
Place the mix hopper cover in position. Periodically,
during the day’s operation, check to be sure there is a
substantial amount of mix in the hopper.
ALWAYS FOLLOW LOCAL HEALTH CODES.
Rinsing
Step 1
Figure 26
Pour two gallons (7.6 liters) of cool, cleanwater intothe
mix hopper. With the brushes provided, scrub the mix
hopper and the mix inlet hole.
Closing Procedure
To disassemble this unit, the following items will be
needed:
S
S
S
S
Two cleaning pails
Necessary brushes (provided with freezer)
Cleaner
Single service towels
Draining Product From The
Freezing Cylinder
Step 1
Place the power switch in the “OFF” position as far
ahead of cleaning time as possible to allow frozen
product to soften for easier cleaning.
Figure 27
Step 2
Raise the hopper cover. If the unit is equipped with an
air/mix feed tube, take it to the sink for cleaning.
Step 2
Step 3
With a pail beneath the door spout, place the power
switch in the “WASH” position and move the draw
handle to the right. Drain all the rinse water from the
freezing cylinder. When the rinse water stops flowing
from the door spout, move the draw handle to the left
and place the control switch in the “OFF” position.
If local health codes permit the use of rerun, place
a sanitized, NSF approved stainless steel rerun
container beneath the door spout. Place the power
switch in the “WASH” position and move the draw
handle to the right. When all the product stops flowing
from the door spout, move the draw handle to the left
and place the power switch in the “OFF” position.
Place the sanitized lid on the rerun container and place
it in the walk- in cooler.
Repeat this procedure until the rinse water being
drawn from the freezing cylinder is clear.
140804
16
Operating Procedures
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
Cleaning
Brush Cleaning
Step 1
Step 1
Prepare a sink with a cleaning solution (examples:
Kay- 5R or Stera- SheenR). USE WARM WATER
AND FOLLOW THE MANUFACTURER’S SPECIFIC-
ATIONS. (If another approved cleaner is used, dilute
according to label instructions. IMPORTANT: Follow
the label directions. Too STRONG of a solution can
cause parts damage, while too MILD of a solution will
not provide adequate cleaning.) Make sure all brushes
provided with the freezer are available for brush
cleaning.
Prepare a pail of an approved 100 PPM cleaning
solution (examples: 2- 1/2 gal. [9.5 liters] of Kay- 5R
or 2 gal. [7.6 liters] of Stera- SheenR). USE WARM
WATER AND FOLLOW THE MANUFACTURER’S
SPECIFICATIONS.
Step 2
Pour the cleaning solution into the hopper and allow it
to flow into the freezing cylinder.
Step 3
Step 2
While the solution is flowing into the freezing cylinder,
brush- clean the mix hopper and mix inlet hole.
Remove the o- ring and seal from the drive shaft.
Remove the o- ring and the bearing from the torque
rotor.
Step 4
Step 3
Place the power switch in the “WASH” position. This
will agitate the cleaning solution in the freezing
cylinder.
Remove the draw valve, ice buster, front bearing, and
gasket from the freezer door. Remove all o- rings.
Note: To remove the o- ring, use a single service
towel to grasp the o- ring. Apply pressure in an upward
direction until the o- ring pops out of its groove. With
the other hand, push the top of the o- ring forward until
it rolls out of the groove and can be removed easily.
Step 5
Place an empty pail beneath the door spout and move
the draw handle to the right. Draw off all the cleaning
solution. When the solution stops flowing from the door
spout, move the draw handle to the left, and place the
power switch in the “OFF” position.
Step 4
Thoroughly brush- clean all disassembled parts in the
cleaning solution, making sure all lubricant and mix film
is removed. Place all the cleaned parts on a clean, dry
surface to air dry.
Step 5
Disassembly
Return to the freezer with a small amount of cleaning
solution. Brush- clean the rear shell bearing at the
back of the freezing cylinder with the black bristle
brush.
Step 1
BE SURE THE CONTROL SWITCH IS IN THE “OFF”
POSITION.
Step 2
Remove the handscrews, freezer door, beater
assembly, torque rotor, scraper blade and drive shaft
from the freezing cylinder. Take these parts to the sink
for cleaning.
Step 3
Remove the front drip tray and the splash shield. Take
these parts to the sink for cleaning.
Step 4
Remove the rear drip pan from the front panel.
Note: If the drip pan is filled with an excessive amount
of mix, it is an indication the drive shaft seal should be
replaced or properly lubricated.
Figure 28
Step 6
Wipe clean all exterior surfaces of the freezer.
090114
17
Model 430 Torque
Operating Procedures
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 7
Important: Operator Checklist
the rerun with fresh mix in a ratio of 50/50 during
the day’s operation.
During Cleaning and Sanitizing:
j 6. On a designated day of the week, run the mix as
low as feasible and discard after closing. This
will break the rerun cycle and reduce the
possibility of high bacteria and coliform counts.
ALWAYS FOLLOW LOCAL HEALTH CODES
j 7. Properly prepare the cleaning and sanitizing
solutions. Read and follow label directions
carefully. Too strong of a solution may damage
the parts and too weak of a solution will not do
an adequate job of cleaning or sanitizing.
Cleaning and sanitizing schedules are governed
by federal, state, or local regulatory agencies, and
must be followed accordingly. If the unit has a
“Standby mode”, it must not be used in lieu of
proper cleaning and sanitizing procedures and
frequencies set forth by the ruling health
authority. The following check points should be
stressed during the cleaning and sanitizing
operations.
j 8. Temperature of mix in mix hopper and walk- in
cooler should be below 40_F. (4.4_C.).
Regular Maintenance Checks:
j 1. Replace scraper blades that are nicked,
damaged or worn down. Before installing
beater, be certain the scraper blade is properly
attached.
CLEANING AND SANITIZING MUST BE
PERFORMED DAILY.
Troubleshooting Bacterial Count:
j 2. Check rear shell bearing for signs of wear
(excessive mix leakage in drip pan) and be
certain it is properly cleaned.
j 1. Thoroughly clean and sanitize machine
regularly, including complete disassembly and
brush cleaning.
j 3. Using a screwdriver and cloth towel, keep the
rear shell bearing and the female square drive
socket clean and free of lubricant and mix
deposits.
j 2. Use all brushes supplied for thorough cleaning.
The brushes are specially designed to reach all
mix passageways.
j 4. Dispose of o- rings and seals if they are worn,
torn, or fit too loosely, and replace with new
ones.
j 3. Use the white bristle brush to clean the mix feed
tube, which extends from the hopper down to
the rear of the freezing cylinder.
j 5. Follow all lubricating procedures as outlined in
j 4. Use the black bristle brush to thoroughly clean
the rear shell bearing located at the rear of the
freezing cylinder. Be sure to have a generous
amount of cleaning solution on the brush.
“Assembly”.
j 6. Check the condenser(s) for accumulation of dirt
and lint. Dirty condensers will reduce the
efficiency and capacity of the machine.
Condensers should be cleaned monthly with a
soft brush. Never use screwdrivers or other
metal probes to clean between the fins.
j 5. IF LOCAL HEALTH CODES PERMIT THE
USE OF RERUN, make sure the mix rerun is
stored in a sanitized, covered stainless steel
container and used the following day. DO NOT
prime the machine with rerun. When using
rerun, skim off the foam and discard, then mix
Note: For machines equipped with an air filter,
it will be necessary to vacuum clean the filters
on a monthly schedule.
071205
18
Important: Operator Checklist
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
Winter Storage
If the place of business is to be closed during the winter
months, it is important to protect the freezer by
following certain precautions, particularly if the
building is to be left unheated and subject to freezing
conditions. Disconnect the freezer from the main
power source to prevent possible electrical damage.
Wrap detachable parts of the freezer such as beater,
blades, drive shaft, and freezer door, and place in a
protected dry place. Rubber trim parts and gaskets
can be protected by wrapping with moisture- proof
paper. All parts should be thoroughly cleaned of dried
mix or lubrication accumulations which attract mice
and other vermin.
Your local Taylor Distributor can perform this service
for you.
19
Model 430 Torque
Important: Operator Checklist
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 8
Troubleshooting Guide
PROBLEM
PROBABLE CAUSE
REMEDY
PAGE
REF.
1. No product being
dispensed.
a. Power switch is in the “OFF”
position.
a. Place power switch in the
“AUTO” position.
15
b. Improper mixing of product.
b. Carefully follow directions
for mixing product.
- - -
c. Inadequate mix in hopper.
c. Fill hopper with mix.
16
10
d. Product frozen- up in freezing
cylinder.
d. Adjust viscosity adjustment
accordingly.
e. Unit out on reset.
e. Place power switch in the
“OFF” position. Press the
reset button. Return
10
control switch to “AUTO”.
f. Beater assembly is not
rotating at all or
counterclockwise. Control
switch is not in “AUTO”.
f. The power switch must be
in “AUTO”. If beater is
rotating counterclockwise,
call service technician to
correct rotation.
1
g. Unit is unplugged.
g. Plug in power cord.
- - -
- - -
h. Tripped circuit breaker or
blown fuse.
h. Reset circuit breaker or
replace fuse.
2. Unit will not operate in the
“AUTO” or “WASH” mode.
a. Unit unplugged at wall
receptacle.
a. Plug in power cord.
- - -
- - -
10
b. Tripped circuit breaker or
blown fuse.
b. Reset circuit breaker or
replace fuse.
c. Unit out on reset.
c. Place the power switch in
the “OFF” position. Press
the reset button. Return
control switch to “AUTO”.
3. No compressor operation
in the “AUTO” mode.
a. Beater motor is out on
overload.
a. Place control switch in
“OFF” position. Press the
reset button. Return
10
control switch to “AUTO”.
b. Condenser dirty A/C.
b. Clean condenser monthly.
a. Fill hopper with mix.
18
16
4. Product too thick.
a. Inadequate mix in hopper.
b. Improper mixing of product.
b. Carefully follow directions
for mixing product.
- - -
c. The viscosity adjustment is
set incorrectly.
c. Adjust the viscosity control.
10
13
d. The torque arm is not
installed.
d. Install the torque arm.
20
Troubleshooting Guide
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
PROBLEM
PROBABLE CAUSE
REMEDY
PAGE
REF.
5. Product too thin.
a. Missing, incorrectly installed,
or bad scraper blade.
a. Install or replace scraper
blade.
11
- - -
10
b. Improper mixing of product.
b. Carefully follow directions
for mixing product.
c. The viscosity adjustment is
set incorrectly.
c. Adjust accordingly.
d. Incorrect beater rotation.
e. Dirty condensers.
d. Contact service technician.
e. Clean regularly.
- - -
18
6. Scored walls of freezing
cylinder.
a. Broken pin on beater
assembly.
a. Repair or replace beater
assembly.
- - -
b. Front bearing worn or
missing.
b. Replace or install front
bearing.
12
11
7. Excessive leakage into
rear drip pan.
a. Improper or inadequate
lubrication of drive shaft
seal.
a. Use correct lubricant
(Taylor Lube) and follow
lubrication procedures.
b. Bad or missing seal on drive
shaft.
b. Replace seal every 3
months.
22
- - -
11
c. Worn rear shell bearing.
c. Contact service technician
for replacement.
8. Excessive leakage from
door spout.
a. Improper or inadequate
lubrication of draw valve
o- rings.
a. Use correct lubricant
(Taylor Lube) and follow
lubrication procedures.
b. Bad or missing o- rings on
draw valve.
b. Replace o- rings every 3
months.
22
11
9. Unable to remove drive
shaft.
a. Lubrication on square end of
drive shaft.
a. Do not lubricate square
end. Contact service
technician for replacement.
b. Rounded corners of drive
shaft, drive coupling, or both.
b. Contact service technician
to replace drive shaft, drive
coupling, or both.
- - -
21
Model 430 Torque
Troubleshooting Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 9
Parts Replacement Schedule
PART DESCRIPTION
EVERY 3
MONTHS
EVERY 6
MONTHS
ANNUALLY
QUANTITIES
TO BE
REPLACED
Drive Shaft Seal
X
X
X
X
X
X
1
1
1
1
1
2
1
Drive Shaft O- Ring
Scraper Blade
Freezer Door Gasket
Front Bearing
Draw Valve O- Rings
Black Bristle Brush - 1” x 2”
Inspect & Replace
if Necessary
Maximum
Maximum
Maximum
White Bristle Brush - 1- 1/2” x 2”
White Bristle Brush - 3” x 7”
Inspect & Replace
if Necessary
1
1
Inspect & Replace
if Necessary
Refer to the Parts List when ordering the above parts.
22
Parts Replacement SchedDuolewnload from Www.Somanuals.com. All Manuals Search And Download.
Model 430 Torque
Section 10 Limited Warranty on Equipment
TAYLOR COMPANY LIMITED WARRANTY ON FREEZERS
Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited
warranty on new Taylor-branded freezer equipment available from Taylor to the market generally (the “Product”)
to the original purchaser only.
LIMITED WARRANTY
Taylor warrants the Product against failure due to defect in materials or workmanship under normal use and
service as follows. All warranty periods begin on the date of original Product installation. If a part fails due to
defect during the applicable warranty period, Taylor, through an authorized Taylor distributor or service agency,
will provide a new or re- manufactured part, at Taylor’s option, to replace the failed defective part at no charge for
the part. Except as otherwise stated herein, these are Taylor’s exclusive obligations under this limited warranty for
a Product failure. This limited warranty is subject to all provisions, conditions, limitations and exclusions listed
below and on the reverse (if any) of this document.
Product
Soft Serve
Part
Limited Warranty Period
Five (5) years
Insulated shell assembly
Frozen Yogurt
Shakes
Refrigeration compressor
(except service valve)
Five (5) years
Beater motors
Two (2) years
Two (2) years
Two (2) years
Smoothies
Frozen Beverage
Batch Desserts
Beater drive gear
Printed circuit boards and
Softech controls beginning
with serial number H8024200
Parts not otherwise listed in
this table or excluded below
One (1) year
LIMITED WARRANTY CONDITIONS
1. If the date of original installation of the Product cannot be verified, then the limited warranty period begins
ninety (90) days from the date of Product manufacture (as indicated by the Product serial number). Proof of
purchase may be required at time of service.
2. This limited warranty is valid only if the Product is installed and all required service work on the Product is
performed by an authorized Taylor distributor or service agency, and only if genuine, new Taylor parts are
used.
3. Installation, use, care, and maintenance must be normal and in accordance with all instructions contained in
the Taylor Operator’s Manual.
4. Defective parts must be returned to the authorized Taylor distributor or service agency for credit.
5. The use of any refrigerant other than that specified on the Product’s data label will void this limited warranty.
LIMITED WARRANTY EXCEPTIONS
This limited warranty does not cover:
1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of
defective parts, replacement parts, or new Products.
2. Normal maintenance, cleaning and lubrication as outlined in the Taylor Operator’s Manual, including cleaning
of condensers.
131202
23
Model 430 Torque
Limited Warranty on Equipment
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Replacement of wear items designated as Class “000” parts in the Taylor Operator’s Manual.
4. External hoses, electrical power supplies, and machine grounding.
5. Parts not supplied or designated by Taylor, or damages resulting from their use.
6. Return trips or waiting time required because a service technician is prevented from beginning warranty
service work promptly upon arrival.
7. Failure, damage or repairs due to faulty installation, misapplication, abuse, no or improper servicing,
unauthorized alteration or improper operation or use as indicated in the Taylor Operator’s Manual, including
but not limited to the failure to use proper assembly and cleaning techniques, tools, or approved cleaning
supplies.
8. Failure, damage or repairs due to theft, vandalism, wind, rain, flood, high water, water, lightning, earthquake
or any other natural disaster, fire, corrosive environments, insect or rodent infestation, or other casualty,
accident or condition beyond the reasonable control of Taylor; operation above or below the electrical or
water supply specification of the Product; or components repaired or altered in any way so as, in the
judgment of the Manufacturer, to adversely affect performance, or normal wear or deterioration.
9. Any Product purchased over the Internet.
10. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the
inadequacy or interruption of electrical service.
11. Electricity or fuel costs, or increases in electricity or fuel costs from any reason whatsoever.
12. Damages resulting from the use of any refrigerant other than that specified on the Product’s data label will
void this limited warranty.
13. Any cost to replace, refill or dispose of refrigerant, including the cost of refrigerant.
14. ANY SPECIAL, INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY
NATURE WHATSOEVER. Some jurisdictions do not allow the exclusion of incidental or consequential
damages, so this limitation may not apply to you.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from
jurisdiction to jurisdiction.
LIMITATION OF WARRANTY
THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS
AND/OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER’S SOLE
REMEDY WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE
COMPONENTS UNDER THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL
OR INCIDENTAL DAMAGES (INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS,
PROPERTY DAMAGES OR SERVICE EXPENSES) ARE EXPRESSLY EXCLUDED. THE EXPRESS
WARRANTIES MADE IN THIS LIMITED WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGED
BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER.
LEGAL REMEDIES
The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect or
complaint with the Product, stating the defect or complaint and a specific request for repair, replacement, or other
correction of the Product under warranty, mailed at least thirty (30) days before pursuing any legal rights or
remedies.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL 61072, U.S.A.
24
Limited Warranty on Equipment
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 11
Limited Warranty on Parts
TAYLOR COMPANY LIMITED WARRANTY ON TAYLOR GENUINE PARTS
Taylor Company, a division of Carrier Commercial Refrigeration, Inc. (“Taylor”) is pleased to provide this limited
warranty on new Taylor genuine replacement components and parts available from Taylor to the market generally
(the “Parts”) to the original purchaser only.
LIMITED WARRANTY
Taylor warrants the Parts against failure due to defect in materials or workmanship under normal use and service
as follows. All warranty periods begin on the date of original installation of the Part in the Taylor unit. If a Part fails
due to defect during the applicable warranty period, Taylor, through an authorized Taylor distributor or service
agency, will provide a new or re- manufactured Part, at Taylor’s option, to replace the failed defective Part at no
charge for the Part. Except as otherwise stated herein, these are Taylor’s exclusive obligations under this limited
warranty for a Part failure. This limited warranty is subject to all provisions, conditions, limitations and exclusions
listed below and on the reverse (if any) of this document.
Part’s Warranty Class Code or Part
Class 103 Parts¹
Limited Warranty Period
Three (3) months
Class 212 Parts²
Twelve (12) months
Twelve (12) months
No warranty
Class 512 Parts
Class 000 Parts
Taylor Part #072454 (Motor- 24VDC *C832/C842*)
Four (4) years
LIMITED WARRANTY CONDITIONS
1. If the date of original installation of the Part cannot be otherwise verified, proof of purchase may be required
at time of service.
2. This limited warranty is valid only if the Part is installed and all required service work in connection with the
Part is performed by an authorized Taylor distributor or service agency.
3. The limited warranty applies only to Parts remaining in use by their original owner at their original installation
location in the unit of original installation.
4. Installation, use, care, and maintenance must be normal and in accordance with all instructions contained in
the Taylor Operator’s Manual.
5. Defective Parts must be returned to the authorized Taylor distributor or service agency for credit.
6. This warranty is not intended to shorten the length of any warranty coverage provided pursuant to a separate
Taylor Limited Warranty on freezer or grill equipment.
7. The use of any refrigerant other than that specified for the unit in which the Part is installed will void this
limited warranty.
1, 2
Except that Taylor Part #032129SER2 (Compressor-Air-230V SERV) and Taylor Part #075506SER1
(Compressor-Air-115V 60HZ) shall have a limited warranty period of twelve (12) months when used in Taylor
freezer equipment and a limited warranty period of two (2) years when used in Taylor grill equipment.
131202
25
Model 430 Torque
Limited Warranty on Parts
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITED WARRANTY EXCEPTIONS
This limited warranty does not cover:
1. Labor or other costs incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of
defective Parts, replacement Parts, or new Parts.
2. Normal maintenance, cleaning and lubrication as outlined in the Taylor Operator’s Manual, including cleaning
of condensers or carbon and grease buildup.
3. Required service, whether cleaning or general repairs, to return the cooking surface assemblies, including
the upper platen and lower plate, to an operational condition to achieve proper cooking or allow proper
assembly of release sheets and clips as a result of grease build-up on the cooking surfaces, including but
not limited to the platen and plate, sides of the shroud or top of the shroud.
4. Replacement of cooking surfaces, including the upper platen and lower plate, due to pitting or corrosion (or
in the case of the upper platen, due to loss of plating) as a result of damage due to the impact of spatulas or
other small wares used during the cooking process or as a result of the use of cleaners, cleaning materials
or cleaning processes not approved for use by Taylor.
5. Replacement of wear items designated as Class “000” Parts in the Taylor Operator’s Manual, as well as any
release sheets and clips for the Product’s upper platen assembly.
6. External hoses, electrical power supplies, and machine grounding.
7. Parts not supplied or designated by Taylor, or damages resulting from their use.
8. Return trips or waiting time required because a service technician is prevented from beginning warranty
service work promptly upon arrival.
9. Failure, damage or repairs due to faulty installation, misapplication, abuse, no or improper servicing,
unauthorized alteration or improper operation or use as indicated in the Taylor Operator’s Manual, including
but not limited to the failure to use proper assembly and cleaning techniques, tools, or approved cleaning
supplies.
10. Failure, damage or repairs due to theft, vandalism, wind, rain, flood, high water, water, lightning, earthquake
or any other natural disaster, fire, corrosive environments, insect or rodent infestation, or other casualty,
accident or condition beyond the reasonable control of Taylor; operation above or below the gas, electrical or
water supply specification of the unit in which a part is installed; or Parts or the units in which they are
installed repaired or altered in any way so as, in the judgment of Taylor, to adversely affect performance, or
normal wear or deterioration.
11. Any Part purchased over the Internet.
12. Failure to start due to voltage conditions, blown fuses, open circuit breakers, or damages due to the
inadequacy or interruption of electrical service.
13. Electricity, gas or other fuel costs, or increases in electricity or fuel costs from any reason whatsoever.
14. Damages resulting from the use of any refrigerant other than that specified for the unit in which the Part is
installed will void this limited warranty.
15. Any cost to replace, refill or dispose of refrigerant, including the cost of refrigerant.
16. ANY SPECIAL, INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY
NATURE WHATSOEVER. Some jurisdictions do not allow the exclusion of incidental or consequential
damages, so this limitation may not apply to you.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from
jurisdiction to jurisdiction.
26
Limited Warranty on Parts
Model 430 Torque
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITATION OF WARRANTY
THIS LIMITED WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS
AND/OR REMEDIES UNDER THE LAW, INCLUDING ANY IMPLIED WARRANTIES OR CONDITIONS OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. THE ORIGINAL OWNER’S SOLE
REMEDY WITH RESPECT TO ANY PRODUCTS SHALL BE REPAIR OR REPLACEMENT OF DEFECTIVE
PARTS UNDER THE TERMS OF THIS LIMITED WARRANTY. ALL RIGHTS TO CONSEQUENTIAL OR
INCIDENTAL DAMAGES (INCLUDING CLAIMS FOR LOST SALES, LOST PROFITS, PRODUCT LOSS,
PROPERTY DAMAGES OR SERVICE EXPENSES) ARE EXPRESSLY EXCLUDED. THE EXPRESS
WARRANTIES MADE IN THIS LIMITED WARRANTY MAY NOT BE ALTERED, ENLARGED, OR CHANGED
BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON, WHATSOEVER.
LEGAL REMEDIES
The owner must notify Taylor in writing, by certified or registered letter to the following address, of any defect or
complaint with the Part, stating the defect or complaint and a specific request for repair, replacement, or other
correction of the Part under warranty, mailed at least thirty (30) days before pursuing any legal rights or remedies.
Taylor Company
a division of Carrier Commercial Refrigeration, Inc.
750 N. Blackhawk Blvd.
Rockton, IL 61072, U.S.A.
27
Model 430 Torque
Limited Warranty on Parts
Download from Www.Somanuals.com. All Manuals Search And Download.
BLK
BLK
PRP/WHT
GRN/YEL
WHT/PRP
WHT
WHT/RED
FUSE
WHT/BLK
BRN
ORG/WHT
RED/WHT
BLU/WHT
L2
L1
COMP
BTR
BLU
ORG
BLK/WHT
BLK/WHT
BLK
BLK
WHT
WHT
WHT
WHT
WHT
GRN/YEL
GRN/YEL
GRN/YEL
MAIN
START
RED
BLU
WHT
BLK
Taylor Company
Model 430 Torque
050367-12
c
08/14
2014 Carrier Commercial Refrigeration, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
BLK
BLK
PURPLE/WHT
GRN/YEL
WHT/PURPLE
WHT
WHT/RED
FUSE
WHT/BLK
BRN
ORG/WHT
RED/WHT
BLU/WHT
L2
L1
COMP
BTR
BLU
ORG
BLK/WHT
BLK/WHT
BLK
WHT
WHT
WHT
WHT
WHT
GRN/YEL
GRN/YEL
GRN/YEL
MAIN
START
RED
BLU
WHT
BLK
BLK
BLK
WHT
GRN
WHT
GRN/YEL
BRN
BLK
BLU
WHT
YEL/GRN
GRN/YEL
Taylor Company
Model 430 Torque
050367-27
c
08/14
2014 Carrier Commercial Refrigeration, Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
|