TOA Electronics Speaker F 122CU User Manual

Rev. A  
INSTRUCTION MANUAL  
CEILING SPEAKER SYSTEM  
F-122CU  
Please follow the instructions in this manual to obtain the optimum results from this unit.  
We also recommend that you keep this manual handy for future reference.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. SAFETY PRECAUTIONS  
• Be sure to read the instructions in this section carefully before use.  
• Make sure to observe the instructions in this manual as the conventions of safety symbols and messages  
regarded as very important precautions are included.  
• We also recommend you keep this instruction manual handy for future reference.  
Safety Symbol and Message Conventions  
Safety symbols and messages described below are used in this manual to prevent bodily injury and property  
damage which could result from mishandling. Before operating your product, read this manual first and  
understand the safety symbols and messages so you are thoroughly aware of the potential safety hazards.  
Indicates a potentially hazardous situation which, if mishandled, could  
result in death or serious personal injury.  
WARNING  
Indicates a potentially hazardous situation which, if mishandled, could  
result in moderate or minor personal injury, and/or property damage.  
CAUTION  
• Use the specified mounting hardware in  
combination. Doing otherwise may cause the unit  
or component to fall off, resulting in personal injury.  
WARNING  
• Leave the installation to your TOA dealer because  
the installation requires expert knowledge.  
Improper installation may cause the unit to fall,  
resulting in personal injury and/or property  
damage.  
• Should the following irregularity be found during  
use, immediately stop operating the unit and  
contact your nearest TOA dealer. Further attempt  
to use under this condition may cause fire or  
electric shock.  
· If you detect smoke or a strange smell coming  
from the unit  
· If no tone sounds  
• Install the unit in a location that can structurally  
support the weight of the unit and its mounting  
hardware. Doing otherwise may result in the unit  
falling down and causing personal injury and/or  
property damage.  
CAUTION  
• Avoid installing the unit in humid or dusty locations,  
in locations exposed to the direct sunlight, near the  
heaters, or in locations generating sooty smoke or  
steam as doing otherwise may result in fire or  
electric shock.  
• Do not use other methods than specified to mount  
the unit. Extreme force is applied to the unit and  
the unit could fall off, possibly resulting in personal  
injuries.  
• Attach the safety wire to the unit. If not attached,  
the unit could fall off, resulting in personal injury.  
• Do not operate the unit for an extended period of  
time with the sound distorting. This is an indication  
of a malfunction, which in turn can cause heat to  
generate and result in a fire.  
• Tighten each screw securely. Ensure that the unit  
has no loose joints after installation to prevent  
accidents that could result in personal injury.  
• Never hold the diffuser section as a handle to carry  
the unit during installation. If the diffuser breaks off,  
the unit could fall from an elevated position,  
resulting in possible personal injury.  
2. GENERAL DESCRIPTION  
The F-122CU is a flush-mounted ceiling speaker that offers a wide frequency range of high-quality sound  
output. Use of its supplied mounting hardware and optional HY-TB1 Tile Bar Bridge permits it to be versatilely  
mounted to match a wide range of applications and installation locations.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. FEATURES  
• Bass-reflex speaker system designed to provide a wide frequency range and high power handling capability.  
• Wide-dispersion flush-mount ceiling speaker design employs unique acoustic construction to realize a wide  
area of coverage. Uniform sound output levels are achievable not only directly under the speaker, but also  
over a wide radius.  
• Because the speaker is provided with both low- and high-impedance operating capability, it can be used in  
many different applications. Front panel-mounted input selector switch permits easy verification and change  
of current impedance settings.  
• Easy installation. Can be quickly and accurately mounted to ceilings.  
• Rotating front grille can be installed quickly and conveniently.  
• Attractive exterior design specially created by an interior designer blends naturally with any architectural  
space, enhancing the immediate area's sense of harmony.  
4. NOMENCLATURE AND DIMENSIONS  
Unit: mm (inches)  
[Front]  
[Side]  
40 (137/64)  
238 (9 3/8)  
Front grille (accessory)  
Safety wire hook  
[Rear]  
Safety wire (accessory)  
Connector cover  
Choke bracket  
Mounting hole: ø200 (77/8)  
[Ceiling mounting]  
Ceiling reinforcement ring  
(accessory)  
Ceiling panel  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. MOUNTING HARDWARE INSTALLATION  
Before mounting the speaker, determine the most appropriate method for the existing ceiling structure.  
Be sure to use an optional HY-TB1 Tile Bar Bridge in combination with the supplied ceiling  
reinforcement ring.  
[Installation view on Drop Ceilings]  
Because the bridge rails are 603 mm (23 47/64") in length, be sure to match them to the ceiling tile size during  
installation.  
Caution  
Set the bridge rails so that both ends fit securely into the T-grids, even if the ceiling tile accidentally falls off.  
Reinforcement ring mounting screw  
Tie-plate mounting screw  
Tie-plate  
(preinstalled on Bridge rail)  
HY-TB1  
(optional)  
Bridge rail  
T-grid  
Ceiling tile  
Ceiling reinforcement ring (accessory)  
[Installation view on Dry Wall Ceilings]  
Caution  
Only install the Tile Bar Bridge on ceiling frames that can structurally support the weight of the speaker(s).  
Reinforcement ring mounting screw  
Tie-plate mounting screw  
Tie-plate  
(preinstalled on Bridge rail)  
HY-TB1  
(optional)  
Bridge rail  
Ceiling frame  
Ceiling panel  
Ceiling reinforcement ring (accessory)  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 1. Cut a ø200 mm (7 7/8") hole in the ceiling.  
ø200 5 mm (77/8 13/64")  
Ceiling panel  
Use the supplied paper pattern to position and trace the hole.  
Step 2. Install the HY-TB1 in the ceiling.  
Loosen the two reinforcement ring mounting screws in each tie-plate to the point that they do not fall  
out of their holes.  
Tie-plate  
HY-TB1  
(optional)  
Bridge rail  
Tie-plate mounting screw  
Reinforcement ring mounting screws  
(Leave these screws loose.)  
[For Drop Ceiling]  
HY-TB1 (optional)  
2-foot tile  
• Mounting to 2-foot tiles  
Align the two bridge rails as shown in the figure  
at right.  
T-grid  
HY-TB1 (optional)  
600 mm tile  
• Mounting to 600 mm tiles  
Align the two bridge rails diagonally at an angle  
of 10° – 15°.  
10° 15°  
T-grid  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 3. Place the supplied reinforcement ring on the ceiling panel.  
Fold the reinforcement ring in half* and insert it  
through the mounting hole in the ceiling panel,  
then open it with its tabs facing up.  
Place the ring on the ceiling panel aligning it  
with the mounting hole.  
Mounting hole  
* The reinforcement ring is too large to be  
inserted into the mounting hole unless folded.  
Ceiling reinforcement ring  
(accessory)  
Reinforcement ring placed on the ceiling panel  
These tabs must  
face upward,  
away from the hole.  
Step 4. Attach the ceiling reinforcement ring to  
each tie-plate using 2 reinforcement ring  
mounting screws.  
Reinforcement ring mounting screw  
1
Tie-plate  
Ceiling reinforcement ring  
2
Fit closely to the back surface  
of the ceiling panel.  
If the ceiling reinforcement ring does not line  
up accurately with the ceiling mounting hole,  
adjust its position by either loosening the tie-  
plate mounting screws and sliding the tie-  
plate into correct position, or by shifting the  
tie-plate mounting screws to the appropriate  
holes in the Tile Bridge rails.  
Tie-plate mounting screw  
Tie-plate  
The ceiling reinforcement ring can be moved  
in the direction indicated by the arrows.  
Note  
Be sure to tighten the tie-plate mounting  
screws after completing the adjustment.  
Ceiling reinforcement ring  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 5. Attach a safety wire to prevent the speaker from accidentally falling.  
To attach, tie one end of the supplied safety wire around the speaker's safety wire hook, and tie its  
snap ring around the installed HY-TB1 or a solid structure.  
Note  
When there is no gap between the bridge rails and the ceiling panel, to secure the safety wire, tie the  
wire around a solid structure (pipe, building frame, etc.).  
Safety wire (accessory)  
Ceiling reinforcement ring  
(accessory)  
Ceiling frame  
HY-TB1 (optional)  
Ceiling panel  
Safety wire (accessory)  
Safety wire hook  
Speaker unit  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. WIRING  
6.1. Using the Speaker in UL1480 Category UUMW  
Choke bracket  
Remove the choke bracket and the cover plate  
from the speaker.  
Cover plate  
Note  
The removed choke bracket is not used.  
Flexible metal conduit (3/8" or 1/2")  
Cover plate  
Conduit fitting  
To install this speaker as a fire alarm signaling  
service UUMW, use flexible conduit of 3/8 or 1/2  
inch trade size and the UL514B listed conduit  
fitting of the same trade size.  
Mount the conduit fitting to the cover plate.  
Connect the conduit to the fitting, and wire the  
detachable input connector.  
Detachable input connector  
(For wiring the input connector, refer to p. 12.)  
Replace the cover plate to the speaker.  
Plug the wired input connector into the speaker's  
socket.  
Connector cover  
After completing the speaker cable connection, turn the connector cover  
in the direction indicated by the arrow, and fix the cover with 2 screws.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.2. Using the Speaker in UL1480 Category UEAY only  
6.2.1. Wiring through hard or flexible conduit  
Note  
The choke bracket equipped with the speaker has not been evaluated by UL, for conduit connection and  
UL514B Standard.  
Flexible conduit of 3/8 or 1/2 inch trade size and the UL514B conduit fitting of the same trade size can also be  
used. For the method of conduit connection, refer to p. 9.  
Loosen the screw to allow the speaker cable to pass through.  
Flexible conduit  
Plug the wired input connector into the speaker's socket,  
then pull the speaker cable from the choke bracket.  
(For wiring the input connector, refer to p. 12.)  
Choke bracket  
Accommodating larger diameter conduit  
The choke bracket accommodates up to 3/8-inch  
(9.5 mm) flexible conduit. When larger diameter  
conduit should be fit, use a suitable fitting  
commercially available by replacing the existing  
choke bracket with it. Detaching the choke  
bracket by unscrewing it exposes a 7/8-inch (22  
mm) hole. Install the alternate fitting there.  
Note  
Ensure that the flexible conduit is securely fixed.  
Retighten the screw to fix  
the flexible conduit.  
Connector cover  
After completing the speaker cable connection, turn the connector cover  
in the direction indicated by the arrow, and fix the cover with 2 screws.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.2.2. Wiring with naked cables  
Loosen the screw to allow the speaker cable to pass through.  
Plug the wired input connector into the speaker's socket,  
then pull the speaker cable from the choke bracket.  
(For wiring the input connector, refer to p. 12.)  
Choke bracket  
Note  
Retighten the screw to fix  
the speaker cable.  
Ensure that the speaker cable is securely fixed.  
Connector cover  
After completing the speaker cable connection, turn the connector cover  
in the direction indicated by the arrow, and fix the cover with 2 screws.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. CABLE CONNECTION TO INPUT CONNECTOR  
Recommended cable types  
Solid copper wire:  
ø1.0 – ø1.6 mm  
(equivalent to AWG 18 14)  
Stranded copper wire: 0.75 2.5 mm2  
(equivalent to AWG 18 14)  
Cover mounting screw  
Step 1. Loosen the 2 cover mounting screws, and rotate the  
connector cover in the direction indicated by the  
arrow in the figure at right.  
Speaker unit  
Connector cover  
Detachable input  
connector  
Step 2. Remove the detachable input connector from the  
speaker's socket, and loosen the screw of the  
terminal to be used.  
Speaker unit  
Step 3. Insert the stripped cable end into the terminal and tighten the terminal screw with a screwdriver.  
[If not bridging] [If bridging]  
From Amplifier  
Caution  
If not making bridge connections,  
be sure to tighten unused terminal  
screws to avoid their vibration.  
5 mm  
(13/64")  
To the  
next speaker  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. SPEAKER INSTALLATION  
Caution  
In  
Before mounting, check to be sure that the speaker's  
3 mounting tabs are turned inside the unit as shown  
in the figure.  
Out  
If turned outward, the speaker cannot be inserted  
through the mounting hole.  
Mounting tab  
Step 1. Insert the speaker through the mounting hole till it  
contacts the ceiling panel. While doing so, avoid  
directly touching the speaker's diffuser section.  
Mounting hole  
Speaker unit  
WARNING  
Never hold the diffuser section as a handle to  
carry the speaker during installation. If the  
diffuser breaks off, the unit could fall from an  
elevated position, resulting in possible  
personal injury.  
Diffuser section  
Diffuser section  
Step 2. Rotate and tighten the mounting tab axis screws (3 places) on the unit clockwise to their full stop in  
order to grip the ceiling panel with the mounting tabs.  
Mounting tab  
Mounting tab axis screw  
Use an electric screwdriver to tighten.  
(Tightening torque: 6 10 kgf·cm)  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Step 3. Set the input power.  
Turn the input selector switch (on the unit's front) to  
set it to the desired input impedance.  
(Factory-preset to 170 .)  
Note  
Setting positions "8 " and "16 " can be used in  
UL1480 Category UEAY only.  
Step 4. Attach the front grille.  
Align the tabs (3 places) on the back side of the grille  
with the corresponding notches in the unit, then rotate  
the grille to full stop in the direction indicated by the  
"LOCK" arrow.  
Speaker unit  
Tip  
The front grille employs a double-locking system that  
clicks into place once partway through rotation, but  
only locks into position at its point of full rotation.  
Always be sure to rotate the grille to its full stop.  
Notch (3 places)  
LOCK  
Tab (3 places)  
Front grille (accessory)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. REMOVING THE SPEAKER FOR MAINTENANCE  
9.1. Detaching the Front Grille  
Turn the front grille counterclockwise to full stop, then lightly  
pull it downward.  
1
Unlock  
Tip  
The front grille employs a double-locking system.  
If the grille cannot be detached when lightly pulled downward,  
it likely has not yet been fully rotated back to the detachment  
position. In such cases, take care to rotate the grill fully  
counterclockwise in order to release the lock.  
Front grille  
Pull lightly.  
2
9.2. Removing the Speaker  
Rotate the 3 mounting tab axis screws counterclockwise. The mounting tabs rise as they turn, allowing the  
speaker to be removed.  
Caution  
When loosening the mounting tab axis screws, support the speaker by hand to prevent it from falling.  
Screw cap  
Mounting tab  
Mounting tab axis screw  
Use an electric screwdriver to detach.  
Caution  
Be sure to set the screwdriver's torque for under 4 kgf·cm.  
Failure to do so may cause the Screw cap and the Mounting tab to fall off  
on the rear of ceiling panel.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
10. REPAINTING THE SPEAKER  
Follow the procedure below when repainting the front grille:  
Step 1. Clean the front grille before painting.  
Wipe with a soft cloth dampened in a detergent.  
Caution  
Do not use thinner or other volatile liquids to clean the grille.  
Step 2. Spray on a uniform, thin coat of paint.  
Cautions  
Avoid painting with a roller or brush, as the grille mesh holes could become clogged with paint.  
Use appropriate spray paints for the front grille (grille and frame) materials.  
Grille: Rolled steel plate  
Frame: Fire-resistant ABS resin (acrylic paint)  
Be sure to follow the directions indicated on the paint when painting.  
Step 3. After the paint has dried, apply another light coat.  
Caution  
Repeating Step 2, apply two or more light coats of paint.  
Application of one thick coat of paint all at once may cause drips or unevenness to show up in the  
painted finish, or clog the mesh holes.  
11. INPUT OVERLOAD PROTECTION FUNCTION  
The F-122CU features an internal input overload protection circuitry. If an extremely high input level is fed to  
the unit, the protection circuitry automatically cuts off the signal to the speaker element.  
A drastic reduction in sound volume indicates that the protection circuitry has been enabled.  
In such cases, simply reduce the amplifier volume. The protection circuitry will automatically reset in  
approximately 10 seconds. After reset, try to maintain the volume at a level slightly lower than before.  
Caution  
This protection circuitry does not completely protect the unit against extremely high input power levels.  
Depending on the type or duration of excessive power input, the protection circuitry might not be enabled,  
resulting in damage to the speaker element. Also, if the excessive power input continues for a long period of  
time, the circuitry may not be capable of resetting to its original condition.  
Use the system with care so that the speakers are not exposed to excessive power input.  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12. SAFETY AGENCY COMPLIANCE  
This product is for indoor use only.  
S8460  
16VP  
Fire Protective Signaling Speaker  
16VP  
Signaling Speaker  
The F-122CU's front-mounted rotary switch permits selection of speaker handling power (wattage) on 25 V or  
70 V line operation or low impedance (8 or 16 ) operation.  
Depending on the switch settings, the unit complies with the different UL Categories as follows.  
Note: Setting to the "8 " and "16 " positions allows the unit to comply with Category UEAY only.  
12.1. Setting to the Following Positions  
70 V Line  
5 W  
25 V Line  
Setting Position 0.5 W 1.5 W  
15 W 30 W 0.06 W 0.2 W 0.6 W 1.9 W 3.7 W  
[Fire protective signaling speaker, UL1480 Category UUMW]  
Products Listed under this category are suitable for use in the following configurations:  
a. For fire alarm signaling service in conjunction with Listed compatible emergency communication and  
relocation equipment and/or fire alarm control unit, the combination of which is intended to be installed in  
accordance with the applicable requirements of NFPA 72, the National Electrical Code (NEC) and the local  
authority having jurisdiction.  
b. For general (non-fire alarm) signaling service in conjunction with compatible Listed audio equipment, the  
combination of which is intended to be installed in accordance with the applicable requirements of the  
National Electrical Code (NEC) and the local authority having jurisdiction.  
[Suitable for use in air-handling spaces (UL2043)]  
Fire Test for Heat and Visible Smoke Release for Discrete Products and their Accessories Installed in Air-  
Handling Spaces (1998) - NFPA 70 National Electrical Code (NEC) 2002, Article 300-22 (c) and NFPA 90A  
Installation of air-conditioning and ventilation systems, section 2-3.10.1 (a) exception 3.  
[Sound Pressure Level (SPL) specs]  
Loudspeaker sound pressure level is measured per UL1480/ANSI-S1.12/ANSI-S1.2 in the specified  
reverberant chamber.  
70 V Line  
5 W  
25 V Line  
Setting Position 0.5 W 1.5 W  
dB at 10 feet  
15 W 30 W 0.06 W 0.2 W 0.6 W 1.9 W 3.7 W  
74 dB 78 dB 83 dB 87 dB 90 dB 65 dB 70 dB 75 dB 79 dB 82 dB  
12.2. Setting to 8 or 16 Position  
[General signaling speaker, UL1480 Category UEAY ]  
Products Listed under this category are suitable for use in general (non-fire alarm) signaling service in  
conjunction with compatible Listed audio equipment, the combination of which is intended to be installed in  
accordance with the applicable requirements of the National Electrical Code (NEC) and the local authority  
having jurisdiction.  
[Suitable for use in air-handling spaces (UL2043)]  
Fire Test for Heat and Visible Smoke Release for Discrete Products and their Accessories Installed in Air-  
Handling Spaces (1998) - NFPA 70 National Electrical Code (NEC) 2002, Article 300-22 (c) and NFPA 90A  
Installation of air-conditioning and ventilation systems, section 2-3.10.1 (a) exception 3.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13. SPECIFICATIONS  
Enclosure  
Bass reflex type  
30 W (High Impedance)  
Rated Input  
Power Handling Capacity Continuous pink noise:  
60 W (8 ), 30 W (16 )  
Impedance  
70 V line: 170 (30 W), 330 (15 W), 1 k(5 W), 3.3 k(1.5 W),  
10 k(0.5 W)  
25 V line: 170 (3.7 W), 330 (1.9 W), 1 k(0.6 W), 3.3 k(0.2 W),  
10 k(0.06 W)  
16 , 8 Ω  
Frequency Response  
Speaker Component  
UL Code  
70 20,000 Hz  
12 cm (5") cone-type  
UL1480 (UUMW/UEAY), UL2043  
Mounting Hole  
ø200 mm (7 7/8")  
Maximum ceiling thickness: 37 mm (1 29/64")  
Input Terminal  
Usable Cable  
Finish  
Removable locking connector with screw-down terminals  
(2 input terminals and 2 bridge terminals)  
Solid copper wire:  
ø1.0 – ø1.6 mm (Equivalent to AWG 18 14)  
Stranded copper wire: 0.75 2.5 mm2 (Equivalent to AWG 18 14)  
Enclosure:  
Baffle:  
Steel plate, plating  
Fire-resistant ABS resin (resin material grade: UL-94 V-0 or  
its equivalent), black  
Rim:  
Fire-resistant ABS resin (resin material grade: UL-94 V-0 or  
its equivalent), white, paint  
Punching net: Steel plate, white, paint  
ø230 mm (9 1/16") x Depth 238 mm (9 3/8")  
3.8 kg (including mounting accessories)  
Dimensions  
Weight  
Note: The design and specifications are subject to change without notice for improvement.  
Accessories  
Front grille ............................................................ 1  
Ceiling reinforcement ring .................................... 1  
Safety wire (approx. 60 cm or 23 5/8") .................. 1  
Paper pattern ....................................................... 1  
Optional Component  
HY-TB1 (Tile Bar Bridge): Use this bridge when mounting the speaker unit to drop ceiling or weak dry wall  
ceiling.  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Printed in Indonesia  
533-06-090-20  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Tokina Camera Accessories TVB3516DCIR User Manual
Toshiba Car Satellite Radio System C850 User Manual
Toshiba DVD Player MD13N1 R User Manual
Toshiba Portable Media Storage DFP 2000A User Manual
Transition Networks Switch MIL SW8T1GPA User Manual
TRENDnet Tablet Accessory TEW ASAL 1 User Manual
Vantec Computer Drive NST D100UFS User Manual
Viking Dishwasher VDB325E User Manual
Vivitar Camera Lens VIV 35MM S User Manual
Vornado Humidifier Ultrasonic Humidifiers User Manual