Tanita Scale TBF 560 User Manual

TBF-560BODYFAT  
MONITOR/SCALE  
Instruction Manual  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tanita TBF-560 Body Fat Monitor/Scale  
Quick Start  
Use this section to begin using the unit immediately. We recommend that you read the Instruction Manual  
thoroughly before making full use of the monitor.  
7
Before you start  
You must complete the sequence on “Preparation before use”.  
Taking measurements before programming the monitor  
16  
If you want to measure your body weight and body fat percentage before or without programming the monitor, see the  
section on Taking measurements of a guest that does not have a PERSONAL key.  
Programming a PERSONAL key  
9
If you want to set and store your personal data into a PERSONAL key, see the section on Setting and storing personal  
data in memory.  
Taking measurements once you have programmed a PERSONAL  
key  
11  
To take your body fat and body weight measurements after programming your personal key, see the section on How to  
measure your body weight and body fat percentage.  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of contents  
Page  
Introduction  
Safety precautions  
1
!
Important notes for users  
2
4
Quick start  
Principles of body fat percentage measurement  
What is body fat percentage?  
Body fat percentage measurement  
Body fat percentage fluctuations in a day  
Advantages of the TANITA TBF-560  
5
Features and functions of the TBF-560  
Components  
5
5
6
6
6
6
Measuring platform  
Accessories  
Useful features of the TBF-560  
Switching the weight mode  
Automatic shut-down function  
Preparations before use  
Inserting the batteries  
7
9
7
7
7
7
8
Positioning the measuring platform  
Attaching the support feet  
Handling tips  
Setting current date and time  
Operation of the TBF-560  
Overview of measuring  
9
9
Setting and storing personal data in memory  
How to measure your body weight and body fat percentage  
Recording measurements  
11  
12  
13  
14  
16  
Overriding recorded data protection feature  
Using memory function  
Taking measurements of a guest  
Resetting data  
16  
Reprogramming and storing new data in memory  
Changing height data for growing children  
Changing the date and time  
16  
17  
18  
18  
Replacing the batteries  
19  
20  
21  
Troubleshooting  
Warranty  
Record keeping sheet  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tanita TBF-560 Body Fat Monitor/Scale  
Principles of body fat percentage measurement  
The Tanita Body Fat Monitor/Scale TBF-560 allows you to estimate your body fat  
percentage at home as easily as you measure your weight.  
What is body fat percentage?  
Body fat percentage is the percentage of fat in your body. Until now, your absolute  
weight has determined whether or not you were considered overweight or obese. In  
recent years, the definition of obesity has been refined to mean the presence of excess  
body fat. Too much body fat has been linked to conditions such as high blood pressure,  
heart disease, diabetes, cancer, and other disabling conditions.  
1, 2  
Body Fat Ranges for Standard Adults  
Underfat  
Healthy  
Overfat  
Obese  
Female 20–39  
Age 40–59  
60–79  
0%  
10%  
20%  
30%  
40%  
Male 20–39  
Age 40–59  
60–79  
Underfat  
1 Based on NIH/WHO BMI Guidelines.  
2 As reported by Gallagher, et al., at NY Obesity Research Center.  
To determine the percentage of body fat that is appropriate for your body, consult your physician.  
Healthy  
Overfat  
Obese  
The BIA method  
The TBF-560 uses the BIA (Bioelectrical Impedance Analysis) technique. In this method,  
a safe low-level electrical signal is passed through the body. It is difficult for the signal to  
flow through fat in the human body, but easy to flow through moisture in the muscle  
and other body tissues. The difficulty with which a signal flows through a substance is  
called impedance. So the amount of fat in the body can be accurately estimated by mea-  
suring the impedance. The signal used is very low, making it safe and imperceptible.  
Tanitas patented foot-paddesign sends a safe,  
low-level electrical signal through the body to deter-  
mine its composition.  
The illustration on the left show how the signal travels through the body.  
Body fat percentage fluctuations in a day  
Hydration levels in the body may affect body fat readings. Readings are usually highest  
in the early waking hours, since the body tends to be dehydrated after a long nights  
sleep. For the most accurate reading, a person should take a body fat percentage reading  
at a consistent time of day under consistent conditions.  
Body Fat %  
22  
21  
20  
Besides this basic cycle of fluctuations in the daily body fat readings, variations may be  
caused by hydration changes in the body due to eating, drinking, menstruation, illness,  
exercising, and bathing. Daily body fat readings are unique to each person, and depend  
upon ones lifestyle, job and activities.  
19  
18  
17  
The graph on the left shows an example of daily body fat percentage fluctuations.  
Advantages of the Tanita TBF-560  
6am  
10am  
2pm  
6pm  
10pm Time  
Previously, body fat percentage was determined by measuring the thickness of subcuta-  
neous fat by pinching it with calipers, or by laying a person on a scanning bed and pass-  
ing a current from hand to foot. However, these methods had problems; measurement  
values varied, professional skills were required, and extensive time was required for mea-  
surement. Currently, the standard methods of fat percentage measurement are DEXA  
(dual energy x-ray absorptiometry) and Hydrodensitometry (underwater weighing).  
Daily fluctuations in body fat percentage based  
on the BIA method  
Based on data from both the DEXA and underwater weighing methods, Tanita established  
a formula for estimating the percentage of body fat. There is a high correlation between  
measurements taken with the TBF-560 and those obtained through DEXA and underwa-  
ter weighing.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Features and functions of the TBF-560  
Components  
Measuring platform  
(1)  
Support feet  
(4)  
(4)  
(1)  
(1)  
AA-size batteries  
Instruction manual and warranty  
Educational booklet  
Measuring platform  
1. Display screen  
2. Orange Set button  
3. Green Selection buttons (Up/Down)  
4. Toe electrodes  
5. Heel electrodes  
6. PERSONAL keys (start switch)  
Setting of birth date, Male/Female/Adult Athlete mode, and height for up to  
five persons can be stored in the memory of the PERSONAL keys.  
1
2
3
4
5
6
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tanita TBF-560 Body Fat Monitor/Scale  
Accessories  
1
2
1. Support feet (4)  
For use on carpeting 0.8 inches thick or less; a hard, uncarpeted surface is  
recommended.  
2. AA-size batteries (4)  
These are trial batteries. Their service life will be short. New batteries will last  
for about a year when this unit is used by five persons once every day.  
Useful features of the TBF-560  
The TBF-560 allows you to measure both weight and body fat percentage simultaneously  
as easily and simply as stepping on a scale.  
The TBF-560 can be set for a Male/Female/Adult Athlete, increasing the accuracy of  
the measurements.  
Personal data (birth date, gender, height) can be preset and stored in memory for up  
to five persons. Personal data can be reprogrammed to allow for changes such as a  
child growing.  
Body weight and body fat percentage measurements for five persons can be recorded  
in the memory of the unit. Users current measurements can be compared with past  
readings record for up to 2 years.  
The TBF-560 can also provide body weight and body fat percentage for an unlimited  
number of guests that do not require their data to be recorded in the memory of the unit.  
The TBF-560 alerts you with a No(triggered by a significant weight change) to indi-  
cate the possibility that you have mistakenly used someone elses PERSONAL key.  
Switching the weight mode  
The TBF-560 can record measurements in lb (pounds), kg (kilograms), or st-lb (British  
stone pounds). To select the preferred unit, make sure the monitor is off. Press the  
Green Up and Orange Set buttons simultaneously and release instantly. Press the  
Up/Down buttons to choose the measurement unit (lb/kg/st-lb) you desire, then press  
the Orange Set button. The display screen will flash and you will hear two beeps to  
confirm your selection and store it in memory. (To change weight unit, repeat the  
previous steps.)  
Press buttons simultaneously and release instantly.  
Automatic shut-down function  
The automatic shut-down function shuts off the power automatically in the  
following cases:  
If you interrupt the measurement process.  
The power will shut down automatically within 10 to 20 seconds, depending  
upon the type of operation.  
If an extraordinary weight is applied to the platform.  
If you make a mistake during measurement or a key operation.  
After you have completed the measurement process.  
NOTE: If the power shuts off automatically due to a problem, repeat the steps from the  
beginning (see pp. 9-10 for steps).  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Preparations before use  
Open as shown  
(detachable)  
Direction of the batteries  
Inserting the batteries  
1. Open the battery cover on the back of the measuring platform.  
2. Insert the supplied AA-size batteries as indicated.  
NOTE: Be sure that the polarity of the batteries is set properly. If the batteries are  
incorrectly positioned the fluid may leak and damage floors. If you do not intend to  
use this unit for a long period of time, it is advisable to remove the batteries before storage.  
!
Positioning the measuring platform  
Place the measuring platform on a hard, flat surface where there is minimal vibration to  
ensure safe and accurate measurement.  
NOTE: To avoid possible injury, do not step on the edge of the platform.  
!
Attaching the support feet (carpet use only)  
Insert the support feet into the holes at the four corners on the bottom of the  
measuring platform.  
NOTE: Do not use the support feet on hard, flat surfaces, as the unit may tip over. Do  
not use the measuring platform on any carpeting that is more than 0.8 inches in  
thickness. To avoid unstable readings.  
!
Handling tips  
This monitor is a precision instrument utilizing state-of-the-art technology. To keep the  
unit in the best condition, follow these instructions carefully:  
Do not attempt to disassemble the measuring platform.  
Store the unit horizontally, and place it so that the PERSONAL keys will not be  
pressed accidentally.  
Avoid excessive impact or vibration to the unit.  
Place the unit in an area free from direct sunlight, heating equipment, high  
humidity, or extreme temperature change.  
Never submerge in water. To clean, use a dampened cloth and mild detergent.  
Use alcohol to clean the electrodes.  
When you change the batteries, exchange all four batteries at the same time with  
new AA-size batteries.  
If you need assistance, please call our toll-free customer service number at 1-800-TANITA-8.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tanita TBF-560 Body Fat Monitor/Scale  
Setting current date and time  
NOTE: This unit makes a beepevery time the Orange Set button is pushed and two beepswhen the input data is confirmed.  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
1. Setting the current year  
2. Setting the current month  
3. Setting the current day  
When the batteries are installed, the  
display will flash an arrow pointing  
to DATEand two dashes where  
the yearis to be stored. Use the  
Green Up/Down buttons to specify  
the last two digits of the year. Then  
press the Orange Set button.  
Once the year is set (1998, in the  
example shown above), then use the  
Up/Down buttons to specify the  
month. Then press the Set button.  
Once the month is set (October, in  
the example shown above), then use  
the Up/Down buttons to specify the  
day. Then press the Set button.  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
4. Setting the current hour  
5. Setting the current  
minutes  
Use the Up/Down buttons to  
specify the minutes. Then press  
the Set button. Example: For 35  
minutes, the display will show 35.  
6. Completing the sequence  
Once the day is set (15, in the  
example shown above), then use  
the Up/Down buttons to specify  
the hour (indicate AM or PM).  
Then press the Set button.  
Example: For 5 pm, the display  
shows P 5.  
Then, press the Set button. Two  
beepswill be heard and the  
confirmed data will flash. The  
power will automatically shut off.  
NOTE: Midnight is indicated by A12: 00and noon is indicated by P12: 00.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation of the TBF-560  
Overview of measuring  
To get the most accurate absolute values, measurements should be taken while wearing no clothing, preferably in the evening, and after  
urinating. If you do not undress, always remove your socks or stockings, and be sure the soles of your feet are clean before stepping on  
the measuring platform. Stand erect on the platform. If measurements are to be taken after bathing, the body must be completely dry.  
NOTE: Accurate measurement will not be possible if the soles of your feet are not clean, if your knees are bent or you are in a sitting position.  
It is best to take measurements at the same time each day, preferably in the evening. If doing so is not convenient, remember to wait  
about three hours after rising, eating, or doing hard exercise before taking measurements. While readings taken under other conditions  
may not have the same absolute values, they are accurate for determining the percentage of change, as long as the readings are taken in  
a consistent manner. To monitor progress, compare weight and body fat percentage measurements taken under the same conditions  
over a period of time.  
Setting and storing personal data in memory (Initial setup only)  
To take full advantage of the features and benefits of the TBF-560, your personal data must be programmed into one of the five person-  
al keys. The unit has an automatic shut-down function. If you do not step on the platform after selecting a PERSONAL key, the unit  
will automatically shut off in about 30 seconds.  
Note: In order to use a PERSONAL key that was previously programmed for another person, see the section on Preprogramming a PERSONAL  
key for a new user on page 16.  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
1. Turn on the power  
2. Select a PERSONAL num-  
ber  
Use the Green Up/Down buttons  
to select a PERSONAL number.  
After selecting the number, press  
3. Specify the year of  
your birth  
Use the Orange Set button to turn  
the unit on. The numbers (1-2-3-4-5)  
will appear and the display will flash.  
Use the Up/Down buttons to  
specify the last two digits of the  
year you were born. Then press  
the Set button. Example: For year  
1971, the display will show 71.  
Note: Users with birth dates before 1908 should enter 08as their year of birth.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tanita TBF-560 Body Fat Monitor/Scale  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
4. Specify the month of  
your birth  
Use the Green Up/Down buttons  
to specify the month you were  
born. Then press the Orange Set  
button. Example: For the month of  
June, the display will show 6.  
5. Specify the day of  
your birth  
6. Specify Male/Female  
and Athlete  
Use the Up/Down buttons to  
Press the Up/Down buttons to  
specify the appropriate gender  
specify day you were born. Then  
press the Set button. Example: For  
the 3rd, the display will show 3.  
and whether you are an Athlete.  
Then press the Set button.  
Persons 17 years of age and under  
cannot be entered as an athlete.  
About user modes:  
MALE  
MALE  
TIME  
TIME  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
DATE  
DOB  
DATE  
DOB  
Female  
Male  
Athlete  
WEEK  
WEEK  
MONTH  
MONTH  
This model automatically selects the  
correct mode of calibration based on  
the users preprogrammed date of birth.  
The unit can be used by children who  
are at least 3.6 ft. tall and adults with  
active or sedentary lifestyles.  
7. Specify your height  
Press the Up/Down buttons to  
specify your height (hold the  
buttons down continuously for  
speed setting). Then press the  
Set button.  
8. Completing the sequence  
Once the height is specified, data  
storage is complete. The display  
will flash all data for 3 seconds to  
confirm the programming. The  
power will automatically shut off.  
To set the next PERSONAL key for  
another person, after the power  
shuts off, repeat steps 1 through 8.  
A special athlete mode may be selected  
by those adults who are involved in  
intense aerobic exercise programs  
(approximately 10 hours a week) and  
have a resting heart rate of approxi-  
mately 60 beats-per-minuteexcluding  
professional athletes and bodybuilders.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
How to measure your body weight and body fat percentage  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
lb  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
2. Programmed data  
appears  
1. Turn on the power  
3. Wait until 0.0 lb”  
appears  
Use your toe to tap your PERSONAL  
key that has your preprogrammed  
data (birth date, gender and height).  
The current date will appear.  
Your preprogrammed gender (male,  
in the example) height (58, in  
the example), current age (27, in  
the example) and PERSONAL key  
number (2 in the example) will  
appear. If athlete mode has been  
chosen, it will also appear.  
Then, the display will show 0.0 lb.  
If you step on the platform before  
0.0 lbappears, the unit will not  
function properly.  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
lb  
lb  
DATE  
DOB  
DATE  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
DOB  
MONTH  
MONTH  
MONTH  
4. Step on the platform  
Be sure that your toes and heels  
are correctly aligned with the  
toe and heel electrodes on the  
measuring platform.Your weight  
will be shown first (149.8 lb, in  
the example shown above).  
5. Display shows ooooo”  
o o o o o will appear in the  
display and then disappear  
one by one as your body fat  
percentage is calculated.  
6. Display shows body weight  
and body fat percentage  
The values of body weight  
and body fat percentage will be  
displayed at the same time for 15  
seconds. To store these measure-  
ments, see Recording measured data  
(standard saving sequence) below.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tanita TBF-560 Body Fat Monitor/Scale  
Recording measurements  
The first 2 steps of this sequence are described in more detail in steps 1 through 6 of How to measure body weight and body fat  
percentage, shown on page 11.  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
lb  
lb  
lb  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
1. Turn on the power  
2. Take measurements  
3. Record measurements  
While the values of body weight  
and body fat percentage are dis-  
played, press the Orange Set  
button (you have a maximum of 15  
seconds to do this from the time  
these measurements appear on the  
screen). The numbers will flash a  
few times and the unit will make  
two beepsto confirm recording  
the data.  
Using your toe, tap the PERSONAL  
key (2, in the example shown above)  
that has your preprogrammed data.  
The current date will appear and then  
the preprogrammed gender, height,  
and current age. Then the display  
will show 0.0 lb. If you step on  
the platform before 0.0 lbappears,  
the unit will not function properly.  
Be sure that your toes and heels are  
correctly aligned with the toe and  
heel electrodes on the measuring  
platform. Your weight will be  
shown first (149.8 lb, in the example  
shown above). Then your body fat  
percentage (21.3%, in the example  
shown above).  
MALE  
TIME  
FEMALE  
ATHLETE  
lb  
DATE  
WEEK  
DOB  
MONTH  
4. Availability of previously  
recorded data  
An arrow pointing to WEEKwill  
flash, to indicate the availability of  
comparisons with previously  
recorded measurements. If you  
choose to compare the current  
reading with previously recorded  
measurements, follow the sequence  
on Using memory function.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Overriding recorded data protection feature  
If another persons PERSONAL key is selected by mistake and a measurement is taken, then incorrect data could be recorded to  
that PERSONAL key. In order to avoid this, when the unit detects a large weight change (of more than the previous weight multi-  
plied by 1/16 ) within a two week period, the display will show Noand will not measure. However, if a person has had a large  
weight change during this period of time, and wants to record the new measurement, follow the procedure below.  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
ATHLETE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
lb  
lb  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
1. Turn on the power  
and take measurement  
2. Unit does not record  
measurements due to a  
3. Reconfirm PERSONAL key  
and record measurement  
Reconfirm that you are using your  
PERSONAL key, then measure again  
within 1 minute. Press the Set but-  
ton. Noflashes in the  
display. Then press the Set button  
again within 5 seconds. The unit will  
make two beepsto indicate that  
the measurement was recorded this  
time.  
significant weight change  
If the change in body weight is more  
than the previous weight multiplied  
by 1/16, the unit will not record the  
measured values even if the Set  
button is pressed to record. No”  
will flash in the display.  
Using your toe, tap the PERSONAL  
key that has your preprogrammed  
data. Wait for 0.0 lbto appear  
before stepping on the platform. Be  
sure that your toes and heels are  
correctly aligned with the toe and  
heel electrodes on the measuring  
platform. The unit will measure  
the values of body weight and body  
fat percentage (149.8 lb and 21.3%,  
respectively, in the example  
shown above).  
Note: The unit will record the values of body weight and body fat percentage only once for a  
certain date. If a person takes measurements several times a day, only the last values of body  
weight and body fat percentage will be recorded for the day within that 24 hour period.  
MALE  
TIME  
FEMALE  
ATHLETE  
lb  
DATE  
WEEK  
DOB  
MONTH  
4. Availability of previously  
recorded data  
An arrow pointing to WEEKwill  
flash, to indicate the availability of  
comparisons with previously  
recorded measurements.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tanita TBF-560 Body Fat Monitor/Scale  
Using memory function  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
ATHLETE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
lb  
lb  
lb  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
1. Turn on the power  
2. Take measurements  
3. Comparing current data  
with last weeks data  
Using your toe, tap PERSONAL  
key (2, in the example shown  
above) that has your prepro-  
Be sure that your toes and heels are  
correctly aligned with the toe and  
heel electrodes on the measuring  
platform. Your weight will be  
shown first (149.8 lb, in the example  
shown above). Then your body fat  
percentage (21.3%, in the example  
shown above).  
Step off the measuring platform.  
An arrow pointing to WEEKwill  
flash to indicate the availability of  
comparisons with previously  
recorded measurements. Press the  
Green Down button to select 1”  
(for 1 week past). The difference  
between the current and last weeks  
reading will be displayed.  
grammed data. The current date will  
appear and then the preprogrammed  
gender, height, and current age.  
Then the display will show 0.0 lb.  
If you stand on the platform before  
0.0 lbappears, the unit will not  
function properly.  
Note: You must have recorded data in order to use the memory function. Any user who  
doesnt have a PERSONAL key can not use the memory function.  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
lb  
lb  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
4. No data recorded for  
week/month  
If you havent recorded data for  
a given week or month, nothing  
will be displayed.  
5. Comparing current data  
6. Comparing current data  
with data from 3 to 12  
weeks ago  
You may continue pressing the  
Down button to compare the  
current data with past data. The  
monitor will store weekly aver-  
ages for up to 12 weeks. You can  
use the Up button to see the  
more recent averages.  
with data from 2 weeks ago  
Press the Down button again, a  
2will appear, and the difference  
between the current data and the  
average from 2 weeks ago will be  
displayed.  
Note: Weekly readings stored beyond 12 weeks will automatically be combined to create  
monthly averages. Averages for months 3 through 24 will be stored and available for  
comparison to the current reading.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
lb  
lb  
lb  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
7. Comparing current data  
8. Comparing current  
data with data from the  
past 3 to 24 months  
You may continue pressing the  
Down button to compare the  
current data with past data. The  
monitor will average up to 24  
months (2 years) of stored data.  
9. Viewing the actual  
reading  
While the difference is showing  
press and hold the Set button and  
the averaged measurement for the  
selected week or month will be  
displayed.  
with stored data by month  
Once you have compared the  
current data with the past 12  
weeks press the Down button once  
more and an arrow will appear  
next to MONTHon the display.  
3will appear and the difference  
between the current data and the  
averaged data from three months  
ago will be displayed.  
The following examples illustrate the memory function feature:  
MALE  
TIME  
FEMALE  
Recorded readings are averaged weekly starting on Sunday and ending on Saturday. A  
monthly average is calculated using the weekly averages within a given calendar month.  
ATHLETE  
lb  
DATE  
WEEK  
DOB  
With the arrow pointing to WEEKthe difference between the current reading and  
MONTH  
the previous 12 weeks will be displayed.  
1 The difference between the current reading and last weeks average  
10. Finish using the  
memory function  
2 The difference between the current reading and the average 2 weeks ago  
WEEK  
Wait about 20 seconds without  
operating the monitor to end the  
memory display function and the  
power will automatically shut off.  
MONTH  
3 The difference between the current reading and the average 3 weeks ago  
4 The difference between the current reading and the average 4 weeks ago  
With the arrow pointing to MONTHthe difference between the current reading  
and the previous 24 months will be displayed. To get to Month Modepress the  
Down button 13 times.  
3 The difference between the current reading and the average 3 months ago  
WEEK  
4 The difference between the current reading and the average 4 months ago  
MONTH  
5 The difference between the current reading and the average 5 months ago  
6 The difference between the current reading and the average 6 months ago  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tanita TBF-560 Body Fat Monitor/Scale  
Taking measurements of a guest that does not have a PERSONAL key  
The TBF-560 allows the measurement of body weight and body fat percentage of a person who does not have a PERSONAL key.  
The procedure is as follows:  
1. Use the Green Up button to turn on the unit.  
2. Follow the procedure in steps 3 to 8 on Setting and storing personal data in memory on pages 9 to 10. Do not use the  
PERSONAL key number.  
3. Press the Orange Set button. The current date will appear on the display. Then follow the procedure How to measure your body  
weight and body fat percentage (steps 2 to 6) to measure the guests body weight and body fat percentage. The guests measurements  
will not be recorded in the memory of the unit.  
Resetting data  
Reprogramming a personal key for a new user  
Follow this procedure to use a PERSONAL key that was previously programmed for another person.  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
1. Select the PERSONAL  
2. Change the year,  
3. Confirmation of  
reprogramming  
key to be reprogrammed  
Select a PERSONAL key (2, in the  
example shown above), using the  
same process described under  
Setting and storing personal data  
in memory (steps 1 and 2). Then,  
the preprogrammed year of birth  
(71, in the example shown above)  
and an arrow pointing to DOB”  
will appear and flash.  
month and day of birth,  
and the height  
The display will show the word  
CLEARand the PERSONAL  
key being reprogrammed. If this  
is correct press and hold the Set  
button. Two beepswill be heard  
and the confirmed data will flash.  
The power will automatically  
shut off.  
Use the Up/Down buttons to  
change the last two digits of  
the year of birth (to 75, in the  
example shown above). Then  
press the Orange Set button.  
Follow the same procedure to  
change the month of birth, day  
of birth, and height, as needed.  
Note: All of the previously recorded information such as body weight and body  
fat percentage averages for the selected PERSONAL key will be lost.  
!
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Changing height data for growing children  
Follow this procedure to use a PERSONAL key that was previously programmed for another person.  
Note: If birth date is changed at any time, the unit will assume the personal key is being reprogrammed for another user and will erase  
any recorded measurements. Simply confirm birth year, month and date by pressing the Set button and continue on to adjust the height.  
!
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
1. Turn on the power  
Use the Orange Set button to  
turn the unit on. The numbers  
(1-2-3-4-5) will appear and the  
display will flash.  
2. Select the PERSONAL key  
requiring height change  
3. Confirm the year of birth  
Since no change is needed on the  
year of birth, press the Set button  
to confirm it. The year of birth  
will stop flashing. Then, the pre-  
programmed month of birth (May,  
in the example above) will appear  
and the display will flash.  
Use the Green Up/Down buttons to  
select the PERSONAL key number  
(which is number 4 in the example  
shown above) for the person whose  
height setting needs to be changed.  
Then press the Set button. Then, the  
preprogrammed year of birth (83, in  
the example shown above) will  
appear and the display will flash.  
MALE  
MALE  
TIME  
TIME  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
MONTH  
MONTH  
5. Change the height  
4. Confirm the month  
and day of birth  
Use the Up button to change the  
height (increased to 42.5in the  
example shown above). Then press  
and hold the Set button until 2  
beepsare heard. The confirmed  
data will flash and the power will  
shut off automatically.  
Since no change is needed on the  
month of birth, press the Set button  
to confirm it. The month of birth  
will stop flashing. Then, the prepro-  
grammed day of birth (12th day, in  
the example shown above) will  
appear and the display will flash.  
Since no change is needed on the  
day of birth, press the Set button to  
confirm it. The day of birth will stop  
flashing. Then, the preprogrammed  
height (41.5in the example shown  
above) will appear and the display  
will flash.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Tanita TBF-560 Body Fat Monitor/Scale  
Changing the date and time  
MALE  
MALE  
MALE  
TIME  
TIME  
TIME  
FEMALE  
FEMALE  
FEMALE  
ATHLETE  
ATHLETE  
ATHLETE  
DATE  
DOB  
DATE  
DOB  
DATE  
DOB  
WEEK  
WEEK  
WEEK  
MONTH  
MONTH  
MONTH  
1. Changing the date  
2. Date change completed  
3. Changing the time  
Use the Green Down button to turn  
the unit on. The date and time will  
appear on the display. Press the  
Orange Set button to begin the  
sequence. The flashing arrow will  
point to DATE. Use the Up/Down  
buttons to correct the number at a  
selected date area (selected number  
will flash). Press the Set button to  
change the selected date area from  
year, to month, to day.  
After the date resetting is completed,  
the time setting will flash on the  
display.  
Use the Up/Down buttons to  
correct the number (selected num-  
bers, hours or minutes, will flash).  
Press the Set button after each  
selection. Two beepswill be  
heard and the confirmed data will  
flash. The power will automatically  
shut off.  
Replacing the batteries  
When the batteries run low, the Lomessage will appear on the display window. When this message appears, be sure to replace  
the batteries immediately, since weak batteries will affect the accuracy of your measurements.  
Your settings will not be erased from the memory when you remove the batteries.  
New batteries will last for about one year if five persons use the unit once every day. The unit comes with 4 trial batteries; their  
service life will be short.  
Note: Batteries must be replaced within 5 minutes after removal or the date and time will  
MALE  
need to be reset.  
TIME  
FEMALE  
ATHLETE  
DATE  
DOB  
WEEK  
MONTH  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
If the following problems occur...  
Then...  
Nothing appears in the LCD after  
Check foot alignment. Make sure you wait for 0.0 lbto appear before stepping onto  
initial display.  
the platform. Check to see that the batteries are new and are in the correct position.  
Nothing appears when a PERSONAL key  
is pressed, or  
No data (Male/Female/Adult Athlete, birth date, height) has been stored in memory for  
that PERSONAL key. Enter data.  
the display shows - - - - -and goes off  
when a PERSONAL key is pressed.  
The body fat percentage measurement  
does not appear after the weight  
is measured.  
Vibration will interfere with measurement of the fat percentage. Be sure to stand erect  
and still on the measuring platform. Do not bend your knees. Be sure that shoes and  
socks are removed and check foot alignment. Step off and repeat steps on page 11.  
The body fat percentage measurement  
is extremely low.  
Be sure you are measuring in the correct user mode (Male/Female/Adult Athlete), and  
that the soles of your feet are clean and properly aligned with the guides on the  
measuring platform. Consider whether or not you are overhydrated. Step off and  
repeat steps on page 11.  
The body fat percentage measurement  
is extremely high.  
Be sure you are measuring in the correct user mode (Male/Female/Adult Athlete), and  
that the soles of your feet are clean and properly aligned with the guides on the  
measuring platform. Dehydration, exercise, foot calluses, etc. will interfere with  
measurement of the fat percentage. Step off and repeat steps on page 11.  
The display reads OLinstead of  
Step off the platform and wait for 0.0 lbto appear in the display before stepping  
the weight.  
onto the platform.  
The display reads No”  
If the new body weight is significantly more or less than the last weight measure-  
ment, the unit will assume you are using the wrong PERSONAL key and will not  
measure. See Overriding recorded data protection feature on page 13.  
Technical Support: Please call 1(800) TANITA-8 (USA & Canada only).  
FEDERAL COMMUNICATIONS COMMISSION NOTICE  
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable  
protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance  
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment  
does cause harmful interference to radio or television reception, which can be determined by turning the equipment on and off, the user is encouraged to try to correct the interference by  
one or more of the following measures:  
Reorient or relocate the receiving antenna.  
Increase the separation between the equipment and receiver.  
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  
Consult the dealer or an experienced radio or television technician for help.  
Modifications  
The FCC requires the user to be notified that any changes or modifications made to this device that are not expressly approved by Tanita Corporation may void the users authority to  
operate the equipment.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TANITA PRODUCTS LIMITED WARRANTY  
Not Valid Without Proof of Purchase  
Your Tanita product is warranted to the original consumer only, for one (1) year, to be free from defects in materials and work-  
manship under normal use. This product is designed for Personal use only. Tanita Corporation of America reserves the  
right to nullify the warranty agreement should the product be used in a commercial environment. This warranty is void if the  
product has been tampered with or mistreated, or if the defect is related to servicing or parts not supplied by us. Our obliga-  
tion under this warranty is limited solely to the charge of repairing the product, plus the cost of parts or, at the option of Tanita,  
replacing the product with an equivalent model. There are no express or implied warranties except as listed above. Tanita is  
not liable for incidental or consequential damages for failure or malfunction of the product and any recov-  
ery may not be greater than the purchase price paid for this product. Some states do not allow limitation on how  
long an implied warranty lasts, or the exclusion or limitation of incidental or consequential damages, so the above limitations  
may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state  
to state. No person is authorized to change the terms of this warranty.  
IF PRODUCT IS DEFECTIVE OR NEEDS REPAIR  
Do not return this product to the place of purchase; doing so may delay the processing of your warranty claim.  
Call Tanita at: 1-800-TANITA-8 to receive a Return Authorization Number before returning this product. Include $12.50 for  
handling, return postage and insurance to the facility listed below. Proof of purchase must accompany the product.  
Because of possible loss, we recommend insuring your product, return receipt requested, when using the mail. If you do not  
receive a receipt within a reasonable time, start a tracer through the originating post office. It is important that you pack the  
product carefully prior to shipment to prevent damage in transit and that you include a letter describing in detail the specific  
condition requiring adjustment or repair.  
TANITA PRODUCTS LIMITED AFTER WARRANTY  
All terms and conditions apply as specified above in the original Tanita Limited Warranty except for the cost of labor and parts:  
Minimum charge for After Warranty labor is $30 per hour, plus the cost of parts.  
You will be notified by mail or telephone of the total cost to repair your product to working condition, so prepayment can  
be arranged.  
Your approval is required before any repair work can be performed on your product.  
Please complete the following information and retain for your records.  
MODEL:  
DATE PURCHASED:  
/
/
PURCHASED FROM:  
ADDRESS:  
Please send all returns to:  
Tanita Corporation  
2625 S. Clearbrook Drive  
Arlington Heights, IL 60005 USA  
AStepToward A Healthier Life.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Record keeping sheet  
Use this area to chart your progress by day, week or month to use the information for future reference. Make photocopies of this page  
for more than one user or as needed.  
Date Weight  
%
Date Weight  
%
Date Weight  
%
Date Weight  
%
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS: TBF-560 BODY FAT MONITOR/SCALE  
Unit: lb  
330 lb  
Unit: kg  
150 kg  
Unit: st-lb  
23st-8lb  
Capacity  
*
Graduation*  
0-330 lb / 0.2 lb 0-150 kg / 0.1 kg 0-23st-8lb / 0.2lb  
Body Fat Graduation  
Power Supply  
0.1%  
DC 6V AA-size (UM3-type) dry battery (x4) included  
60 mA maximum  
Power Consumption  
Measuring Current  
50 kHz 500 µA  
Not for professional or commercial use.  
©1998 Tanita Corporation. All rights reserved. 7/98 HDI  
TANITA Corporation  
TANITA Corporation of America Inc.  
2625 S. Clearbrook Drive  
Arlington Heights, IL 60005 USA  
Tel. 847-640-9241 Fax 847-640-9261  
Toll Free 1-800-TANITA-8  
http:// WWW.TANITA.COM (English)  
http:// WWW.TANITA.CO.JP (Japanese)  
14-2, 1-Chome, Maeno-Cho  
Itabashi-Ku, Tokyo, Japan  
Tel. 03-3968-2123 Fax 03-3967-3766  
ISO 9001 Certified  
TANITA UK Ltd.  
TANITA France S.A.  
3-3 Bis, Rue Charcot 92200  
Neuilly-sur-Seine, France  
Tel. 01-5524-9999  
TANITA Health Equipment H.K. Ltd.  
Unit 301-303 3/F Wing On Plaza  
62 Mody Road, Tsimshatsui East  
Kowloon, Hong Kong  
TANITA Europe GmbH  
Dresdener Strasse 25  
D-71065 Sindelfingen, Germany  
Tel. 07031-61896  
Tanita House, Willow Avenue, Denham  
Uxbridge, Middlesex UB9 4AF, Great Britain  
Tel. 01895-232355  
Fax 01895-233116  
Fax 01-5524-9868  
Tel. 852-2838-7111 Fax 852-2838-8667  
Fax 07031-618971  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Shop Vac Vacuum Cleaner MV35 User Manual
Sony Computer Keyboard VGP WKB1 User Manual
Sony Cordless Telephone IT ID20 User Manual
Sony Ericsson GPS Receiver 3200 LS Color User Manual
Sony Headphones XBA1 User Manual
Sony Portable CD Player D EJ620 User Manual
Sony Projector V800QM User Manual
Suzuki Automobile 2010 Grand Vitara User Manual
Sylvania CRT Television C6432TD User Manual
Sylvania Flat Panel Television LD195SL8 User Manual