Sun Fire V440 Server
Installation Guide
Sun Microsystems, Inc.
4150 Network Circle
Santa Clara, CA 95054 U.S.A.
650-960-1300
Part No. 816-7727-10
July 2003, Revision A
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
1. Preparing for Installation
About the Parts Shipped to You
Verify All Parts
1
1
2
2. Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Checklist of 4-Post Rackmounting Tasks
5
6
Inventory for 4-Post Rackmounting
Tools Required for Rackmounting
7
8
Attach the Inner Glides to the Chassis
Prepare the Cabinet 10
9
Locate the Mounting Holes 11
Install the Slide Assemblies 13
Install the Server Into the Cabinet 16
What Next 19
Install the Cable Management Arm 20
Contents
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Secure the Cords and Cables to the Cable Management Arm 25
Install Optional Components 28
Connecting the Cords and Cables 29
Connect the Power Cords to the Server 30
3. Setup and Power-On Procedures 35
Set Up a System Console Device 35
About Connecting the Server to a Terminal Server 36
▼
▼
▼
How to Access the System Console via a Terminal Server 38
How to Access the System Console via an Alphanumeric Terminal 38
How to Access the System Console via tipConnection 39
Prepare to Configure the Primary Network Interface 41
Power On the Server 42
▼
▼
How to Power On via the Power Button 43
A. Background and Reference 49
System LEDs 49
Serial Port Connector 51
Serial Port Connector Diagram 51
Serial Port Connector Signals 51
4-Post Cabinet Requirements 52
iv Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Preface
The Sun Fire V440 Server Installation Guide provides instructions, some background
information, and reference material to help you install a new Sun Fire™ V440 server.
Instructions in Chapters 1 and 3 assume that a system administrator who is
™
experienced with the Solaris operating environment is performing the installation.
However, you do not need Solaris operating environment experience to follow
instructions in Chapter 2, which detail the installation of the Sun Fire V440 server
into a 4-post cabinet.
How This Book Is Organized
This guide is organized into three chapters and one appendix.
Chapter 1 illustrates the contents of the Sun Fire V440 server ship kit, provides
guidelines for planning the installation, and lists the documentation included on the
Sun Fire V440 Server Documentation CD.
Chapter 2 provides instructions for installing the Sun Fire V440 server into a 4-post
cabinet, installing the cable management arm, and routing the cables and cords into
the cable management arm.
Chapter 3 provides instructions for powering on the server and for installing the
Solaris operating environment and additional software.
Appendix A includes background information about the system console and
additional technical specifications, including those for connectors and for the rack.
v
Download from Www.Somanuals.com. All Manuals Search And Download.
Using UNIX Commands
®
This document might not contain information on basic UNIX commands and
procedures such as shutting down the system, booting the system, and configuring
devices.
See one or more of the following for this information:
▼ Solaris Handbook for Sun Peripherals
™
▼ AnswerBook2 online documentation for the Solaris operating environment
▼ Other software documentation that you received with your system
Typographic Conventions
*
Typeface
Meaning
Examples
AaBbCc123
The names of commands, files,
and directories; on-screen
computer output
Edit your .loginfile.
Use ls-ato list all files.
% You have mail.
AaBbCc123
What you type, when
contrasted with on-screen
computer output
% su
Password:
AaBbCc123
Book titles, new words or terms, Read Chapter 6 in the User’s Guide.
words to be emphasized.
Replace command-line
variables with real names or
values.
These are called class options.
To delete a file, type rmfilename.
* The settings on your browser might differ from these settings.
vi Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
System Prompts
Type of Prompt
Prompt
C shell
machine-name%
C shell superuser
machine-name#
Bourne shell and Korn shell
Bourne shell and Korn shell superuser
ALOM system controller
OpenBoot firmware
OpenBoot Diagnostics
$
#
sc>
ok
obdiag>
Related Documentation
Application
Title
Part Number
Late-breaking product
information
Sun Fire V440 Server Product Notes
816-7733
Cabling and power-on
overview
Sun Fire V440 Server Setup:
Cabling and Power-On
816-7734
816-7728
816-7729
816-7730
817-1960
Administration
Sun Fire V440 Server Administration
Guide
Parts installation and
removal
Sun Fire V440 Server Parts Installation
and Removal Guide
Diagnostics and
troubleshooting
Sun Fire V440 Server Diagnostics and
Troubleshooting Guide
Sun Advanced Lights Out Sun Advanced Lights Out Manager
Manager (ALOM) system
controller
(ALOM) 1.1 Online Help
Preface
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessing Sun Documentation
You can view, print, or purchase a broad selection of Sun documentation, including
localized versions, at:
Note – For important safety, compliance, and conformity information regarding the
Sun Fire V440 server, see the Sun Fire V440 Server Safety and Compliance Guide, part
number 816-7731, on the Documentation CD or online at the above location.
Contacting Sun Technical Support
If you have technical questions about this product that are not answered in this
document, go to:
Sun Welcomes Your Comments
Sun is interested in improving its documentation and welcomes your comments and
suggestions. You can submit your comments by going to:
Please include the title and part number of your document with your feedback:
Sun Fire V440 Server Installation Guide, part number 816-7727-10.
viii Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
1
Preparing for Installation
administrator must answer before installing the server software.
This chapter contains the following sections:
▼ “About the Parts Shipped to You” on page 1
▼ “Verify All Parts” on page 2
▼ “Transfer Online Documentation” on page 3
▼ “Plan the Installation” on page 3
About the Parts Shipped to You
Standard components of Sun Fire V440 servers are installed at the factory. However,
if you ordered options such as a PCI card and monitor, these will be shipped to you
separately.
In addition, you should have received the Solaris™ Media Kit and documentation
for all appropriate system software.
Check that you have received everything you ordered.
Note – Inspect the shipping carton for evidence of physical damage. If a shipping
carton is damaged, request that the carrier’s agent be present when the carton is
opened. Keep all contents and packing material for the agent’s inspection.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Verify All Parts
▼ Verify that you have received all the parts of your system.
See the illustration below to identify most of the parts shipped with the system. (Not
shown in the illustration is the RJ-45/ DB-9 adapter, which is also shipped with the
system.)
Ship kit carton
Documentation CD
Ra
c
k
Al
ig
nm
ten
e
T
m
f
pl
Us
e
this
r
ack
4inpstoasllta
postside
aet
tion
or
Grounding strap
Cable management arm
System keys
RJ-45 cable
RJ-45/DB-25
adapter
Inner glides
Slide assemblies
Rackmounting kit carton
Screws, nuts, washers (4 packs)
2
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Transfer Online Documentation
The Sun Fire V440 Server Documentation CD is included in the ship kit. See the
booklet included with the CD for instructions on transferring the documentation to
disk or viewing the documentation directly from the CD.
In addition to this guide, the following documents are included on the Sun Fire V440
Server Documentation CD:
▼ Sun Fire V440 Server Safety Information
▼ Sun Fire V440 Server Product Notes
▼ Sun Fire V440 Server Using Online Documentation
▼ Sun Fire V440 Server Administration Guide
▼ Sun Fire V440 Server Diagnostics and Troubleshooting Guide
▼ Sun Fire V440 Server Parts Installation and Removal Guide
▼ Sun Advanced Lights Out Manager (ALOM) 1.1 Online Help
▼ Sun Fire V440 Server 2-Post Rackmounting Guide
▼ Sun Fire V440 Server Safety and Compliance Guide
Plan the Installation
The Sun Fire V440 server is a general-purpose server. How you set up your server
depends on what you want it to do.
This set of installation procedures is intended to be as “generic” as possible, to
accommodate the variety of uses to which you can apply the server. Even so, you
need to make certain decisions to complete the procedures. If you need background
information to help you answer the following two questions, see the Sun Fire V440
Server Administration Guide.
▼ On which network or networks do you intend to operate the server?
You need to provide specific networking information about the server when you
install the Solaris operating environment.
▼ How do you want to use and configure the server’s internal disks?
▼ What software do you intend to load?
Software included in the Solaris Media Kit or other software products can impose
certain disk space or disk partitioning requirements. Refer to the documentation
accompanying the Solaris software to determine those requirements.
Chapter 1 Preparing for Installation
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Note – Be sure to use a supported version of the Solaris operating environment. See
the Sun Fire V440 Server Product Notes for more information.
What Next
Install the server into a cabinet, following instructions in Chapter 2.
4
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
2
Installing a Sun Fire V440
Server Into a 4-Post Cabinet
This chapter shows you how to install a Sun Fire V440 server into a 4-post Sun™
StorEdge Expansion Cabinet or other Electronic Industries Association
(EIA)-compliant 19-inch (48.26-cm) wide rack. If you are installing a Sun Fire V440
server into a 2-post rack, refer to the 2-post rackmounting instructions that are
included on the Documentation CD in the Ship kit.
Note – To install a server into an EIA-compliant 19-inch wide rack with mounting
holes sized for U.S. dimension screws, use 10-32 screws and 8-32 screws to attach the
slide assemblies to the rack. The rackmounting kit includes 8-32 and 10-32 screws
and washers.
To install a server into an EIA-compliant 19-inch wide rack with mounting holes
sized for metric dimension screws, use M4 or M6 screws—depending on your rack
model—to attach the slide assemblies to the rack. The rackmounting kit includes M4
and M6 screws and washers.
detailed.
▼ “Attach the Inner Glides to the Chassis” on page 9
▼ “Prepare the Cabinet” on page 10
▼ “Locate the Mounting Holes” on page 11
▼ “Install the Slide Assemblies” on page 13
▼ “Install the Server Into the Cabinet” on page 16
▼ “Install the Cable Management Arm” on page 20
5
Download from Www.Somanuals.com. All Manuals Search And Download.
▼ “Secure the Cords and Cables to the Cable Management Arm” on page 25
▼ “Install Optional Components” on page 28
▼ “Connect the Power Cords to the Server” on page 30
▼ “Connect Twisted-Pair Ethernet Cables” on page 32
▼ “Restore the Cabinet” on page 34
For a detailed list of 4-post cabinet requirements, turn to the section, “4-Post Cabinet
Requirements” on page 52.
Step
Task
Refer to This Section
1
Install the inner glides on the
chassis.
“Attach the Inner Glides to the Chassis” on
page 9
2
3
4
Prepare the cabinet.
Locate the mounting holes.
“Install the Slide Assemblies” on page 13
Install the slide assemblies into
the cabinet.
5
6
7
Install the server into the cabinet.
“Install the Server Into the Cabinet” on
page 16
page 20
Secure the cords and cables to the
cable management arm.
Management Arm” on page 25
8
9
Install optional components.
Connect the power cords.
“Install Optional Components” on page 28
“Connect the Power Cords to the Server” on
page 30
10
11
Connect a twisted-pair Ethernet
(TPE) cable.
“Connect Twisted-Pair Ethernet Cables” on
page 32
Restore the cabinet.
“Restore the Cabinet” on page 34
6
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Inventory for 4-Post Rackmounting
You need one 4-post rackmounting kit for each Sun Fire V440 server you intend to
install into a cabinet. The 4-post rackmounting kit is included with the server. You
also need this document and the Rack Alignment template from the ship kit.
Back
Inner glides (2)
Slide assemblies (2)
Front
Cable management arm
Speed pin
R
a
c
k
A
l
i
g
n
m
te
n
e
T
m
p
l
a
et
Rack
Alignment
template
M4 screws (8)
M6 screws (12)
M6 washers (12)
10-32 screws (12)
10-32 washers (12)
Documentation CD
(Installation Guide)
8-32 screws (2)
8-32 nuts (2)
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
7
The plastic bags of hardware contain screws and nuts that are shown below in actual
size.
10-32
8-32
M6
M4
8-32
M6
10-32
Any screws not used for rackmounting are spares.
Note – Bar nuts are required (but not included) for non-threaded cabinets. See the
instructions provided with your cabinet for more information.
Tools Required for Rackmounting
▼ Phillips No. 2 screwdriver (Use to tighten 10-32 and M6 screws.)
▼ Set of appropriate Allen wrenches to remove the side panels on some cabinets
▼ Adjustable wrench to tighten the nuts on the mounting brackets
8
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Attach the Inner Glides to the Chassis
▼ Attach the inner glides to the chassis using four M4 screws for each inner glide.
Position the straight end of each inner glide toward the front of the server. Align the
second hole on the inner glide with the first hole on the chassis.
M4
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
9
Prepare the Cabinet
See the instructions provided with your cabinet.
2. Stabilize the cabinet by extending its anti-tip legs or bolting the cabinet securely
to the floor.
See the instructions provided with your cabinet and read “4-Post Cabinet
Requirements” on page 52.
The following illustration shows two anti-tip legs. Note that some cabinets have
only one such leg.
3. Remove the side panels from the cabinet, if applicable.
See the instructions provided with your cabinet. Removing the side panels can
improve access to the areas where you will install nuts and screws when securing
the server in the cabinet.
10
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Locate the Mounting Holes
▼ Locate and mark the rack rail holes that you will use to attach each slide assembly.
You can either count the holes on the vertical rack rails or use the Rack Alignment
template included with your documentation set. Make sure that each slide assembly
is installed at the same height front-to-back and side-to-side in the rack.
The Rack Alignment template is four rack units (7.00 inch/ 17.78 cm) tall. You use the
Rack Alignment template to ensure that the server is correctly placed within
standard rack unit spacing, in which the top of the system is defined to be midway
between a set of holes separated by 0.5 inch (1.27 cm).
One side of the Rack Alignment template is for 4-post rackmounting and the other is
for 2-post rackmounting. For 2-post rackmounting instructions, refer to the Sun Fire
V440 Server 2-Post Rackmounting Guide included on your Documentation CD.
The 4-post mounting holes on the Rack Alignment template are for mounting the
slide assembly brackets to the vertical rack rails. The upper and lower retainer screw
openings in the template locate the chassis bracket screws that secure the server in
the rack after the server is installed.
The following figure shows both sides of the Rack Alignment template.
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
11
To use the Rack Alignment template, complete these steps:
a. Place the Rack Alignment template over the right front vertical rack rail, then
move the bottom of the template to the location on the rack rail where the
bottom of the server will be located.
Retainer screw hole
Mounting holes
R
a
c
k
A
l
i
g
n
m
te
n
e
T
m
p
l
a
et
b. Adjust the Rack Alignment template until the mounting holes openings are
centered on two holes in the rail and the retainer screw hole is visible.
When you do this, the top of the template is midway between a set of half-inch
holes.
c. Repeat Step a and Step b for the left front vertical rack rail.
12
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Install the Slide Assemblies
Be aware of the following guidelines.
Caution – Ensure that you have stabilized the cabinet by extending its anti-tip legs
or bolting the cabinet securely to the floor.
▼ Install the slide assemblies into the lowest available position.
▼ Install additional servers from the base up in the cabinet.
1. Use the Rack Alignment template to locate and mark mounting holes on the front
vertical rack rails.
See “Locate the Mounting Holes” on page 11.
2. Adjust the back mounting brackets to accommodate the depth of the rack.
▼ Loosen the 8-32 lock nut on each of the back mounting brackets.
▼ Adjust the back mounting bracket forward or backward on each slide assembly to
accommodate the depth of the rack. You may find it necessary to remove the nuts
and reposition the brackets to obtain the correct spacing.
▼ Partially tighten the lock nuts. Do not fully tighten the lock nuts until after you
attach the slide assemblies to the mounting rails.
Lock nut
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
13
3. With the help of an assistant, position one slide assembly on the inside of the
cabinet with the front (short) mounting bracket at the front of the rack.
a. Use the holes you marked in Step 1.
b. Make sure that the slide assembly is level front-to-back.
4. Using two screws for each bracket, attach the front mounting bracket to the front
rail of the cabinet and attach the back (long) mounting bracket to the back rail of
the cabinet.
Count the rack rail holes to ensure that you are matching the holes used on the front
rail.
To attach the slide assembly, use the appropriate screws for your type of rack:
▼ Racks with mounting holes sized for U.S. dimensions require 10-32 screws.
▼ Racks with mounting holes sized for metric dimensions require M4 or M6 screws.
a. Fully tighten the front bracket screws.
b. Partially tighten the back bracket screws.
Do not fully tighten the screws that attach the back brackets to the rack rails until
after you slide the server into the cabinet.
c. Fully tighten the 8-32 lock nuts on the back mounting bracket.
Step 4b.
Step 4a.
Step 4c.
5. Repeat Step 3 and Step 4 for the other slide assembly.
14
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
6. If the depth of the rack is greater than 27.25 inches (69.21 cm), install a
Phillips 8-32 screw and an 8-32 lock nut on each back mounting bracket.
Fully tighten the lock nuts.
7. Make sure that each slide assembly is fully retracted into the cabinet.
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Install the Server Into the Cabinet
Caution – Before you install or remove the server from the cabinet, be sure the
cabinet is stabilized so that it cannot move or tip forward. See the cabinet
documentation for information about stabilizing the cabinet.
!
!
Caution – The server is heavy. Two persons are required to move the server.
Note – Make sure that each slide assembly is fully retracted into the cabinet and
check that the ball-bearing runner on each slide assembly is all the way forward.
1. With one person on each side of the server, lift the server and approach the
cabinet with the back of the server facing the front of the cabinet.
Note – Do not use the vent holes in the server doors as “handles” to lift the server.
2. Align the rounded ends of the inner glides on the server with the slide assemblies
in the cabinet.
Note – Make sure that the inner glides attached to the server are inserted within the
ball-bearing runners.
16
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Holding the server level, slide it evenly into the cabinet until the inner glides
stop.
Tip – Slide the server in and out of the cabinet slowly and carefully to ensure that
the slide assemblies are working correctly and are free from obstructions.
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
17
4. Press the flat spring catch on each inner glide in order to slide the server the rest
of the way into the cabinet.
5. Fully tighten the screws that attach the back brackets to the back rails.
18
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Secure the server to the front rails using four M4, M6, or 10-32 screws, depending
on your cabinet, to attach the brackets to the rack.
What Next
The next tasks are to install the cable management arm and to connect the power
cords and Ethernet (RJ-45) cables.
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
19
Install the Cable Management Arm
This procedure describes how to attach the cable management arm to a server that
is already installed in a cabinet.
You need the following components from the ship kit and the rackmounting kit to
install the cable management arm and to connect the cords and cables:
▼ Cable management arm
▼ Ethernet (RJ-45) cable
You also need two AC power cords, which are not supplied.
AC power cords (2)
(Not supplied in kit)
Ethernet RJ-45 cable
Cable management arm
1. Loosen the four screws that secure the system to the left and right vertical rails at
the front of the cabinet.
2. Slide the server smoothly out of the cabinet about 3 inches (7.62 cm).
Sliding the server out of the cabinet enables easy access to the areas where you will
attach the cable management arm.
3. Attach one end of the cable management arm to the inner glide.
20
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
a. Go to the back of the cabinet. Locate the tab and mounting hole on the curved
end of the left inner glide as viewed from the back.
b. Locate the slot and captive screw on one end of the cable management arm.
The slot and captive screw attach the arm to the inner glide. You can attach the
end of the cable management arm containing the slot and captive screw to either
the left or right inner glide, depending on where the cords and cables connect to
the server. It may be easier for you to route the cords if you attach the cable
management arm to the right inner glide as viewed from the back of the server. If
from the back of the server, turn the arm over so that the bottom becomes the top.
Note that illustrations in this guide show the cable management arm attached to
the left side.
The end of the cable management arm that is not attached to the inner glide
attaches to the slide assembly. See Step 4 for instructions on how to attach the
cable management arm to the slide assembly.
Mounting
hole
Tab
Captive
screw
Slot
Inner
glide
Cable management arm
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
21
c. Fit the slot of the cable management arm over the tab of the inner glide.
Slide the slot over the tab until the captive screw aligns with the mounting hole
on the inner glide.
You may need to rotate the cable management arm flange containing the slot and
captive screw so that you can fit the slot over the tab.
22
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
d. Tighten the captive screw on the cable management arm.
4. Attach the other end of the cable management arm to the slide assembly.
a. Go to the slide assembly on the right side of the server as viewed from the
back.
b. Locate the barrel at the end of the slide assembly.
c. Locate the bracket at the end of the cable management arm.
The bracket has openings at the top and bottom.
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
23
Download from Www.Somanuals.com. All Manuals Search And Download.
d. Slide the cable management arm bracket over the barrel so that the bracket
openings align with the barrel openings.
You may have to rotate the bracket to align the bracket openings with the barrel
openings. You may also have to release the Velcro straps on the cable
management arm to make sliding the assembly into the rack easier.
Cable management
arm bracket
Barrel
e. Locate the speed pin on the end of the cable management arm.
The speed pin secures the cable management arm to the slide assembly.
24
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
f. Insert the speed pin through the aligned openings of the bracket and the barrel
and push the pin down firmly.
Speed
pin
Secure the Cords and Cables to the
Cable Management Arm
This procedure illustrates how to secure the power cords and the Ethernet cable to
the cable management arm. Your server might use additional cables.
1. Install the cable management arm on the server.
See “Install the Cable Management Arm” on page 20.
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
25
2. Locate the oval cutouts in the center section of the cable management arm and the
Velcro straps in the first and third sections.
The cutouts and straps enable you to route the cables and cords and to secure them
to the cable management arm.
Upper lip
Velcro straps
Oval cutouts
First
section
Velcro straps
3. Route the cords and cables between the upper and lower lips of the first section of
the cable management arm.
Ensure that cords and cables provide enough slack to allow routing, yet are taut
enough to avoid obstruction of the slide assemblies.
4. Tie the cords and cables to the first section of the cable management arm.
Use the Velcro straps to tie the cables to the cable management arm. How you tie the
straps to the cable management arm depends on the size and number of your cables.
For example, for a smaller bundle of cables, thread the Velcro straps through the
slots in the upper and lower lips. For a larger bundle of cables, wrap the straps
completely around the cables and the cable management arm.
26
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Group the cords and cables and insert each group into the oval cutouts.
Use both oval cutouts in the center section to route different groups of cords and
cables through the cable management arm. For example, you can group the power
cords and insert them into one oval cutout, and then group the other cables and
insert them into the other oval cutout.
Note – Do not insert the cords or cables into the round cutouts. Use those cutouts to
access and manipulate the cords or cables.
Oval cutouts
Note – You can route the power cords to emerge at either the right or the left side of
the server. The above illustration shows the cords routed to the right as seen from
the back of the server. See the section, “Install the Cable Management Arm” on
page 20, Step 3b, for instructions.
6. Secure the cords and cables to the third section of the cable management arm
using the Velcro straps.
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
27
Install Optional Components
▼ Install any optional components shipped with your system.
If you ordered options that are not factory-installed, see the Sun Fire V440 Server
Parts Installation and Removal Guide for installation instructions.
Note – All internal components except disk drives must be installed by qualified
service technicians only.
Electrostatic Precautions – To protect electronic components from electrostatic
damage, which can permanently disable the system or require repair by Sun service
technicians, note the following guidelines.
▼ Place components on an antistatic surface, such as a Sun antistatic discharge mat,
an antistatic bag, or a disposable antistatic mat.
▼ Always wear an antistatic wrist strap connected to a metal surface on the chassis
when you work on system components.
28
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the Cords and Cables
The following figure shows the Sun Fire V440 server back panel and identifies the
AC power inlets and I/ O ports.
1
2 3
4
5
6
7
Port
Information
1
2
AC inlets
Power cords connect to each AC inlet. Do not connect the
cord to an AC outlet at this point. See “Connect the Power
Cords to the Server” on page 30.
Serial port (ttyb)
This port provides standard serial functionality. Note that
the system controller serial management port is not a
Administration Guide for more information.
3
4
USB ports
See the Sun Fire V440 Server Administration Guide for
information about devices you can connect to these ports.
Ethernet ports
You use these ports to connect to your Ethernet network.
The left port is net0, and the right port is net1. See “Connect
Twisted-Pair Ethernet Cables” on page 32.
5
6
7
External SCSI port
See the Sun Fire V440 Server Administration Guide for
information about the devices you can connect to this port.
Network management port
(NET MGT)
You use this port to access ALOM features by way of the
network.
Serial management port
(SERIAL MGT)
You use this, the default port, to attach the system console
device.
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
29
Connect the Power Cords to the Server
1. Unlock and open the right system door.
2. Insert the system key into the system control keyswitch.
Note that you have two sizes of system keys. The smaller key enables you to close
the system door even while the key is in the system control keyswitch. The door
cannot be closed with the larger key in the keyswitch.
3. Turn the system control keyswitch to the Standby position.
Standby
HDD
HDD
HDD
HDD
3
2
1
0
PS 1
PS 0
4. Slide the server out of the rack far enough to give you convenient access to the
back of the server.
30
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Connect an AC power cord to each AC inlet at the back of the server.
Do not connect the cords to AC power outlets at this point. You connect the cords to
AC outlets during a later step, after you set up a system console device.
A
C
0
A
C
1
AC
0
AC
1
CAUTION: In order to remove all
power from this unit, disconnect
all power cords.
A
TTENTION: Pour mettre le systeme
hors tension, il est imperatif de
debrancher tous les cordons
alimentation
d
0
1
VORSICHT:
Trennen Sie alle
Stromkable um die, gesamte
2
3
1
0
RMC
PCI
5
PCI
4
PCI 3
33 MHz
PCI 2
33/66MHz
PCI
1
PCI
0
33/66MHz
33/66MHz
33MHz
33MHz
SERIAL
10/100/1000
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
31
Connect Twisted-Pair Ethernet Cables
Connect a twisted-pair Ethernet (TPE) cable to one or both of the Ethernet
ports on the back panel. Each network interface is capable of 10-Mbps,
100-Mbps, or 1000-Mbps operation depending on network characteristics.
1. Choose a network port, using the following table as a guide.
Ethernet Port
OBP Devalias Device Path
0
1
net0
net1
/pci@1c,600000/network@2
/pci@1f,700000/network@1
Select the correct TPE connector for the interface you are installing. The server comes
with two TPE connectors on the back panel. Your server might also include one or
more TPE connectors provided on PCI Ethernet interface cards.
For ease of identifying the Ethernet cable later, use a piece of tape or some other
method of marking it to differentiate it from other cables.
Note – The server also provides a TPE connector on the Sun Advanced Lights Out
Manager (ALOM) system controller card. Use this connector to access ALOM
features through a network. See the Sun Fire V440 Server Administration Guide.
32
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Plug in a Category-5 unshielded twisted-pair cable (which is included in your
ship kit) to the appropriate RJ-45 connector.
You should hear the connector tab snap into place. The cable length must not exceed
328 feet (100 meters).
AC
0
AC
1
CAUTION: In order to remove all
power from this unit, disconnect
all power cords.
A
TTENTION: Pour mettre le systeme
hors tension, il est imperatif de
debrancher tous les cordons
alimentation
d
0
1
VORSICHT:
Trennen Sie alle
Stromkable um die, gesamte
2
3
1
0
RMC
PCI
5
PCI
4
PCI
3
PCI 2
33/66MHz
PCI
1
PCI
0
33/66MHz
33/66MHz
33 MHz
33MHz
33MHz
SERIAL
10/100/1000
Note – Because the Sun Fire V440 server has two RJ-45 ports, to help avoid
confusing the two later, you should label each cable at each end, identifying which
cable is connected to which port.
3. Plug in the cable to the RJ-45 outlet to connect to your Ethernet network.
See your network administrator if you need more information about how to connect
to your network.
Chapter 2 Installing a Sun Fire V440 Server Into a 4-Post Cabinet
Download from Www.Somanuals.com. All Manuals Search And Download.
33
Restore the Cabinet
See the instructions provided with your cabinet to complete these steps.
1. Replace the side panels, if applicable.
2. Replace the front and back doors, if applicable.
What Next
The next tasks are to set up a system console device, power on the server, and install
the Solaris operating environment. See Chapter 3.
34
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
CHAPTER
3
Setup and Power-On Procedures
This chapter tells you how to set up a system console device and how to power on
the server. It also provides guidelines for installing the Solaris operating
▼ “How to Access the System Console via tipConnection” on page 39
▼ “Prepare to Configure the Primary Network Interface” on page 41
▼ “Power On the Server” on page 42
▼ “How to Power On via the Power Button” on page 43
▼ “How to Power On via the poweronCommand” on page 44
▼ “Install the Solaris Operating Environment and Additional Software” on page 47
Set Up a System Console Device
To install the Solaris operating environment and any application software, you must
set up a terminal or other device to access the system console. You can either:
▼ Connect the system to a terminal server.
▼ Use an alphanumeric (ASCII) terminal.
▼ Establish a tipconnection from another server.
Regardless of the method you choose, you must connect the device to the serial
management port (SERIAL MGT) on the ALOM card.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
The following section provides background information on connecting the server to
a terminal server. This section is followed by instructions for setting up a terminal
server, followed by instructions for setting up an alphanumeric terminal to access
the system console, and then followed by instructions for setting up a tip
connection from another Sun system.
For more detailed information, see the Sun Fire V440 Server Administration Guide or
the Sun Fire V440 Server Diagnostics and Troubleshooting Guide.
Note – All of the procedures in the following sections assume that you are setting
up a system console device by using the default configuration; that is, the system
console is directed to the ALOM system controller.
About Connecting the Server to a Terminal Server
The serial management port on the Sun Fire V440 server is a data terminal
equipment (DTE) port. The pinouts for the serial management port correspond with
the pinouts for the RJ-45 ports on the Serial Interface Breakout Cable supplied by
Cisco for use with the Cisco AS2511-RJ terminal server. If you use a terminal server
made by another manufacturer, check that the serial port pinouts of the Sun Fire
V440 server match those of the terminal server you plan to use.
If the pinouts for the server serial ports correspond with the pinouts for the RJ-45
ports on the terminal server, you have two connection options:
▼ Connect a serial interface breakout cable directly to the Sun Fire V440 server. See
the Sun Fire V440 Server Administration Guide for details.
▼ Connect a serial interface breakout cable to a patch panel and use the straight-
through patch cable (supplied by Sun) to connect the patch panel to the server.
The following illustration shows how to connect a patch cable between a terminal
server, patch panel, and the serial management port (SERIAL MGT) on the Sun Fire
V440 server.
36
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15
Terminal
server
Straight-through cable
1
2
3
4
5
6
7
8
9
10 11 12 13 14 15
Patch panel
Patch cable to serial management port
Sun Fire V440
server
FIGURE 3-1 Patch Panel Connection Between a Terminal Server and a Sun Fire V440
Server
If the pinouts for the serial management port do not correspond with the pinouts for
the RJ-45 ports on the terminal server, you need to make a crossover cable that takes
each pin on the Sun Fire V440 server serial management port to the corresponding
pin in the terminal server’s serial port.
TABLE 3-1 shows the crossovers that the cable must perform.
TABLE 3-1
Pin Crossovers for Connecting to a Typical Terminal Server
Sun Fire V440 Serial Management Port
(RJ-45 Connector) Pin
Terminal Server Serial Port Pin
Pin 1 (CTS)
Pin 1 (RTS)
Pin 2 (DTR)
Pin 2 (DSR)
Pin 3 (TXD)
Pin 3 (RXD)
Pin 4 (Signal Ground)
Pin 5 (Signal Ground)
Pin 6 (RXD)
Pin 4 (Signal Ground)
Pin 5 (Signal Ground)
Pin 6 (TXD)
Pin 7 (DSR / DCD)
Pin 8 (CTS)
Pin 7 (DTR)
Pin 8 (RTS)
Chapter 3 Setup and Power-On Procedures
37
Download from Www.Somanuals.com. All Manuals Search And Download.
▼ How to Access the System Console via a
Terminal Server
The following procedure assumes that you are accessing the system console device
by connecting a terminal server to the serial management port (SERIAL MGT) of the
Sun Fire V440 server.
For detailed information about system console options, see the Sun Fire V440 Server
Administration Guide.
1. Open a terminal session on the connecting device, and type:
% telnet IP-address-of-terminal-server port-number
For example, for a Sun Fire V440 server connected to port 10000 on a terminal server
whose IP address is 192.20.30.10, you would type:
% telnet 192.20.30.10 10000
Note – At this point, all system information will be delivered to you by way of the
ALOM system controller and its software. ALOM is the default method for
communicating with the Sun Fire V440 server. For detailed information about using
ALOM, consult the Sun Advanced Lights Out Manager (ALOM) 1.1 Online Help and
the Sun Fire V440 Server Administration Guide, which includes information about
reconfiguration options.
2. Continue setup with the section, “Prepare to Configure the Primary Network
Interface” on page 41.
▼ How to Access the System Console via an
Alphanumeric Terminal
The following procedure assumes that you are accessing the system console device
by connecting an alphanumeric terminal to the serial management port (SERIAL
MGT) of the Sun Fire V440 server.
For detailed information about system console options, see the Sun Fire V440 Server
Administration Guide.
1. Turn off power to the alphanumeric terminal.
38
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Attach one end of the serial cable to the alphanumeric terminal’s serial port.
Use an RJ-45 null modem serial cable or an adapter that is appropriate for your
appropriate RJ-45/ DB-9 adapter. Plug in this cable or adapter to the terminal’s serial
port connector.
3. Attach the serial cable’s RJ-45 connector to the server’s serial management port
(SERIAL MGT) on the ALOM card.
See the section, “Connecting the Cords and Cables” on page 29 for an illustration
and chart of the various ports.
4. Connect the alphanumeric terminal’s power cord to an AC outlet and turn it on.
5. Set the terminal to receive:
▼ 9600 baud
▼ 8 bits
▼ No parity
▼ 1 stop bit
▼ No handshake protocol
See the documentation accompanying your terminal for information about how to
configure it.
Note – At this point, all system information will be delivered to you by way of the
ALOM system controller and its software. ALOM is the default method for
communicating with the Sun Fire V440 server. For detailed information about using
ALOM, consult the Sun Advanced Lights Out Manager (ALOM) 1.1 Online Help and
the Sun Fire V440 Server Administration Guide, which includes information about
reconfiguration options.
6. Continue setup with the section, “Prepare to Configure the Primary Network
Interface” on page 41.
▼ How to Access the System Console via tip
Connection
The following procedure assumes that you are setting up a system console device for
the Sun Fire V440 server by connecting the serial port of another Sun system to the
serial management port (SERIAL MGT) of the Sun Fire V440 server.
For detailed information about system console options, see the Sun Fire V440 Server
Administration Guide.
Chapter 3 Setup and Power-On Procedures
Download from Www.Somanuals.com. All Manuals Search And Download.
39
1. Make sure that the Sun system to which you are establishing the tipconnection
is powered on and active.
2. Connect the RJ-45 serial cable and RJ45/DB25 adapter.
Use the cable and adapter to connect the other Sun system’s ttybserial port to the
Sun Fire V440 server’s serial management port (SERIAL MGT). Pinouts, part
numbers, and other details about the serial cable and adapter are provided in the
Sun Fire V440 Server Parts Installation and Removal Guide.
3. Ensure that the /etc/remotefile on the Sun system contains an entry for
hardwire.
Most releases of Solaris operating environment software shipped since 1992 contain
an /etc/remotefile with the appropriate hardwireentry. However, if the Sun
system is running an older version of Solaris operating environment software, or if
the /etc/remotefile has been modified, you may need to edit it. See the Sun Fire
V440 Server Administration Guide for details.
4. In a terminal window on the other Sun system, type:
hostname% tip hardwire
The other Sun system responds by displaying:
connected
The terminal window is now a tipwindow directed to the Sun Fire V440 server via
the other Sun system’s ttybport. This connection is established and maintained
even when the Sun Fire V440 server is completely powered off or just starting up.
Note – Use a terminal tool, not a console tool. Some tipcommands might not work
properly in a console tool window.
Note – At this point, all system information will be delivered to you by way of the
ALOM system controller and its software. ALOM is the default method for
communicating with the Sun Fire V440 server. For detailed information about using
ALOM, consult the Sun Advanced Lights Out Manager (ALOM) 1.1 Online Help and
the Sun Fire V440 Server Administration Guide, which includes information about
reconfiguration options.
5. Continue setup with the section, “Prepare to Configure the Primary Network
Interface” on page 41.
40
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Network Interface
The following instructions assume that you have chosen a network port and have
installed an Ethernet cable, as instructed in the section, “Connect Twisted-Pair
Ethernet Cables” on page 32. Note that some of these steps are optional, depending
on how you want to configure the network. Optional steps are indicated by italics.
1. Choose a host name for the server and make a note of it.
The host name—no longer than 30 characters—must be unique within the network,
consisting only of alphanumeric characters and the dash (-). Do not use a dot in the
host name or begin the name with a number or a special character.
2. Determine the unique Internet Protocol (IP) address of the network interface and
make a note of it.
An IP address must be assigned by the network administrator. Each network device
or interface must have a unique IP address.
3. If the system is part of a subnet, determine the netmask and make a note of it.
An example of a netmask is: 255.255.0.0
4. Determine which name service that the system will use.
Your choices are NIS+, NIS, DNS, LDAP, or None. For information about setting up
a network name service, consult the Solaris Naming Setup and Configuration Guide for
your specific Solaris release.
▼ If the system uses a name service, supply the name of the domain in which the
system resides.
▼ If the name service you use is NIS or NIS+, determine whether you want to specify a
name server or have the installation program find one.
If you want to specify a name server rather than have the installation program
find one, make a note of the server’s host name and the server’s IP address.
▼ If the name service you use is DNS, make a note of the IP addresses for the DNS
server.
You must enter at least one IP address, and you can enter up to three addresses.
▼ If the name service you use is LDAP, provide the following information about your
LDAP profile:
▼
▼
▼
Profile name
Profile server
IP address
Chapter 3 Setup and Power-On Procedures
Download from Www.Somanuals.com. All Manuals Search And Download.
41
During installation of the Solaris operating environment, the software automatically
detects the system’s on-board network interfaces and any installed PCI network
interface cards for which native Solaris device drivers exist. The installation program
then asks you to select one of the interfaces as the primary network interface and
prompts you for the information you gathered. Depending on how you answer other
installation questions, the system may prompt you for setup information in addition
to the information you gathered in the preceding steps.
You can configure only one network interface during installation of the operating
environment. You must configure any additional interfaces separately, after the
operating environment is installed. For more information, see the Sun Fire V440
Server Administration Guide.
After completing installation of the Solaris operating environment (in a later step),
the primary network interface is ready for operation. The device driver for the
server’s on-board Ethernet interfaces is automatically installed with the Solaris
release. For more information about network interfaces and configuring the Sun Fire
V440 server’s second Gigabit Ethernet interface, see the Sun Fire V440 Server
Administration Guide.
Power On the Server
You can use either of two methods to power on the server:
▼ Power on by using the Power button
▼ Power on by using the poweroncommand from the ALOM sc>prompt
For information about the LED status indicators that appear during power-up, see
the Sun Fire V440 Server Administration Guide.
Caution – Never move the server when the server power is on. Movement can
cause catastrophic disk drive failure. Always power off the server and allow several
seconds for the disks to spin down before moving it.
Caution – The AC power cords provide a discharge path for static electricity.
Unless otherwise noted in the Sun Fire V440 Server Parts Installation and Removal
Guide, the cords must remain plugged in to the AC outlets when you install or
handle internal components.
42
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
▼ How to Power On via the Power Button
1. Make sure that your system console device is turned on and active.
2. Turn on power to any peripherals and external storage devices.
Read the documentation supplied with the device for specific instructions.
3. Unlock and open the right system door, as viewed from the front of the system.
4. Insert the system key into the system control keyswitch and turn the system
control keyswitch to the Diagnostics position.
See the Sun Fire V440 Server Administration Guide for information about each system
control keyswitch setting.
The illustration below shows the system control keyswitch and the Power button
locations, as well as the keyswitch position icons..
Power button
Standby
Keyswitch
Normal
Locked
Diagnostics
5. Connect the Sun Fire V440 server’s outlet plug of each power cord to the power
sequencer in the cabinet (if your type of cabinet includes one), to a grounded
outlet strip, or to a grounded AC power outlet.
Note – Each outlet must connect the server to a 15A circuit for North America and
Japan, and to a 10A or 16A circuit for Europe. Consult your local electrical codes for
any additional requirements. See the instructions provided with your cabinet for
information about the power sequencer.
Chapter 3 Setup and Power-On Procedures
Download from Www.Somanuals.com. All Manuals Search And Download.
43
Note – Connect each cord to a separate circuit to maximize system availability.
The Standby Available LEDs on the power supplies are lit, indicating that power is
being supplied to the system.
As soon as you plug in the power cord, several boot messages from the ALOM
software are displayed on your system console device. The ALOM boot messages
end with the ALOM prompt:
sc>
6. At the ALOM prompt (sc>), enter the following command:
sc> console
The system will prompt you to create an administrator password.
7. When prompted, create and then confirm an administrator password.
The ALOM prompt will again be displayed.
8. At the ALOM prompt (sc>), again enter the following command:
sc> console
9. Press the Power button.
The server runs full diagnostics, which can take several minutes. Because the auto-
boot?parameter is set to trueby default, installation of the Solaris operating
environment will begin at this point—if your system administrator has configured
the network for Solaris JumpStart™ installation. If the network is not so configured,
then you must install the operating environment manually, in a later step.
10. Turn the system control keyswitch to the Locked position.
The Locked position disables the Power button, which prevents anyone from
accidentally powering off the server.
11. Remove the system key from the system control keyswitch and keep it in a secure
place.
12. Close and lock the right system door.
▼ How to Power On via the poweronCommand
The following instructions show you how to power on the server by using the
poweroncommand from the ALOM sc>prompt. To use this command, you must
pay careful attention to the ALOM boot messages, as this procedure requires quick
entry of commands.
1. Make sure that your system console device is set up and active.
44
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Turn on power to any peripherals and external storage devices.
Read the documentation supplied with the device for specific instructions.
3. Connect the Sun Fire V440 server’s outlet plug of each power cord to the power
sequencer in the cabinet (if your type of cabinet includes one), to a grounded
outlet strip, or to a grounded AC power outlet.
Note – Each outlet must connect the server to a 15A circuit for North America and
Japan, and to a 10A or 16A circuit for Europe. Consult your local electrical codes for
any additional requirements. See the instructions provided with your cabinet for
information about the power sequencer.
Note – Connect each cord to a separate circuit to maximize system availability.
The Standby LEDs on the power supplies are lit, indicating that power is being
supplied. As soon as you plug in the power cord, several boot messages from the
ALOM software are displayed on your system console device. The ALOM boot
messages end with the ALOM sc>prompt.
4. Unlock and open the right system door, as viewed from the front of the system.
5. Insert the system key into the system control keyswitch and turn the system
control keyswitch to the Diagnostics position.
See the Sun Fire V440 Server Administration Guide for information about each system
control keyswitch setting.
The illustration below shows the system control keyswitch and the Power button
locations, as well as the keyswitch position icons.
Power button
Standby
Keyswitch
Normal
Locked
Diagnostics
Chapter 3 Setup and Power-On Procedures
Download from Www.Somanuals.com. All Manuals Search And Download.
45
6. At the ALOM sc>prompt, type the poweroncommand:
sc> poweron
The ALOM software then prompts you to enter a new administrative password.
7. When prompted, enter and then confirm a new administrative password.
Once again, the ALOM sc>prompt is displayed.
8. At the ALOM sc>prompt, again type the poweroncommand:
sc> poweron
The poweroncommand is executed and the sc>prompt is again displayed.
You must complete the next step quickly, before the ALOM 60-second timeout
expires. In the event that the timeout expires, enter #.to return to the ALOM
prompt.
9. Quickly enter the consolecommand:
sc> console
After running full diagnostics, the system banner is displayed on the system console
device and then the okprompt is displayed. If your system administrator has
configured the network for Solaris JumpStart installation, then installation of the
Solaris operating environment will begin at this point. If the network is not so
configured, then you must install the operating environment manually, in a later
step.
10. Turn the system control keyswitch to the Locked position.
The Locked position disables the Power button, which prevents anyone from
accidentally powering off the server.
11. Remove the system key from the system control keyswitch and keep it in a secure
place.
If you are using the smaller key, you can leave it in place and use the larger key for
the next step.
12. Close and lock the right system door.
46
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Environment and Additional Software
You must have set up a system console device before you can install the Solaris
operating environment. See the section, “Set Up a System Console Device” on
page 35. Be sure that you are using the Solaris operating environment supported by
the Sun Fire V440 server. See the Sun Fire V440 Server Product Notes for additional
information.
Note – The Solaris Media Kit, in which you will find the Solaris operating
environment CDs and additional software CDs, must be ordered separately. Contact
your Sun service provider if you do not have a Solaris Media Kit.
1. Locate your Solaris Media Kit.
2. Install the Solaris operating environment on your server.
▼ Read the Start Here document that is included in the Solaris Media Kit.
▼ Complete each step to install the Solaris operating environment.
Install the software using any of four methods, fully explained in the documentation
included in the Solaris Media Kit:
▼ Solaris Web Start
▼ Solaris interactive installation
▼ Solaris JumpStart or (Custom JumpStart)
▼ Over a network
3. Load additional software from the Solaris Software Supplement CD (optional).
The Solaris Media Kit includes the Solaris Software Supplement CD with additional
software to help you operate, configure, and administer the server. See the
documentation provided in the Solaris Media Kit for a listing of included software.
To install the software from the Solaris Software Supplement CD, use the installation
utility, Solaris Web Start. For instructions, see your Solaris documentation, which is
included in the Solaris Media Kit.
4. Install any software patches listed in the Sun Fire V440 Server Product Notes on
the Documentation CD.
SM
A list of recommended patches is also available on the SunSolve Online Web site at
from your Sun service provider or by downloading them from the SunSolve Online
Web site.
Chapter 3 Setup and Power-On Procedures
Download from Www.Somanuals.com. All Manuals Search And Download.
47
5. Run the SunSM Install Check tool to validate installation configuration.
The tool identifies unsupported firmware and hardware configurations, identifying
conflicts with configuration rules. The tool also ensures that your firmware is current
and that you have all required patches installed. The URL for obtaining this tool is:
What Next
The Sun Fire V440 server is now ready for use and, if you desire, additional
configuration.
▼ Consult the Sun Fire V440 Server Administration Guide for detailed information and
instructions relating to configuration and administration of the server.
▼ Refer to the Sun Fire V440 Server Parts Installation and Removal Guide for parts
replacement and installation information and instructions.
▼ Refer to the Sun Fire V440 Server Diagnostics and Troubleshooting Guide for help
with any problems you may encounter.
▼ Refer to the Sun Advanced Lights Out Manager (ALOM) 1.1 Online Help for
information about how to use the ALOM software.
48
Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
APPENDIX
A
Background and Reference
This appendix includes background and reference information that can help you
with installation of your Sun Fire V440 server. All of the information in this
appendix is related directly to instructions in this guide.
System LEDs
As you install your Sun Fire V440 server, be aware of several system status LED
indicators on both the front and back panels. These indicators provide general
system status, alert you to system problems, and help you to determine the location
of system faults.
At the top left of the server as you look at its front are three general system status
LEDs. Two of these LEDs, the system Service Required LED and the System Activity
LED, provide a snapshot of the overall system status. One LED, the Locator LED,
helps you to locate a specific system quickly, even though it might be one of many
systems in a room. The front panel Locator LED is at the far left in the cluster. The
Locator LED is lit by command from the administrator. For instructions, see the Sun
Fire V440 Server Diagnostics and Troubleshooting Guide.
Other LEDs located on the front of the server work in conjunction with specific fault
LED icons. For example, a power supply fault illuminates the associated power
supply Service Required LED and the system Service Required LED. Since all front
panel status LEDs are powered by the server’s 5-volt standby power source, fault
LEDs remain lit for any fault condition that results in a system shutdown.
Locator, Service Required, and System Activity LEDs are also found at the upper-left
corner of the back panel. Also located on the back panel are LEDs for the server’s
two power supplies and RJ-45 Ethernet ports.
The following tables list and describe the LEDs on the front and back panels: system
status LEDs, power supply LEDs, and hard disk drive LEDs.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
From left to right, system status LEDs operate as described in the following table.
TABLE A-1 System Status LEDs
Name
Description
Locator
This white LED is lit by Sun Management Center or ALOM
software, or by Solaris command, to locate a system.
Service Required
System Activity
This amber LED lights to indicate that the system hardware
or software has detected a system fault.
This green LED lights when the AC power is available and
the operating system is running.
The following table describes the power supply LEDs.
TABLE A-2 Power Supply LEDs
Name
Description
OK-to-Remove
This blue LED lights when it is safe to remove the power
supply from the system.
Service Required
This amber LED lights when the power supply’s internal
circuitry detects a fault in the monitored power supply. Note
that the Service Required LEDs on the front and back panels
also light when this occurs.
Power OK
This green LED lights when the power supply is on and
outputting regulated power within specified limits.
Standby Available This green LED lights when a proper AC voltage source is
input to the power supply.
The following table describes the disk drive LEDs.
TABLE A-3 Hard Disk Drive LEDs
Name
Description
OK-to-Remove
This blue LED lights when it is safe to remove the hard disk
drive from the system.
Service Required Reserved for future use.
Activity This green LED lights when a disk is present in the monitored
drive slot. This LED blinks slowly to indicate that the drive is
spinning up or down, and quickly to indicate disk activity.
50 Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
Further details about the diagnostic use of LEDs are discussed separately in the Sun
Fire V440 Server Diagnostics and Troubleshooting Guide.
Serial Port Connector
Accessible from the back panel of the Sun Fire V440 server is a DB-9 connector
labeled ttybthat serves as a single, general-purpose serial port.
Serial Port Connector Diagram
1 2 3 4 5
SERIAL
6 7 8 9
Serial Port Connector Signals
Pin
1
Signal Description
Data Carrier Detect
Receive Data
Pin
6
Signal Description
Data Set Ready
Request to Send
Clear to Send
2
7
3
Transmit Data
Data Terminal Ready
Ground
8
4
9
Ring Indicate
5
Appendix A
Background and Reference
51
Download from Www.Somanuals.com. All Manuals Search And Download.
4-Post Cabinet Requirements
The server is designed so that you can install it into a 72-inch (184-cm) tall Sun
StorEdge Expansion cabinet or other EIA-compliant industry-standard cabinet that
meets the requirements listed in the following table. You need a Sun rackmounting
kit for each server that you rackmount.
Note – The server is fully serviceable in a 4-post cabinet when it is extended on its
slide assemblies.
TABLE A-4 4-Post Cabinet Requirements
Cabinet Feature
Requirement
Load-bearing capacity
The rack must firmly support the weight of as many Sun
Fire V440 servers installed in the cabinet (each server
weighs up to 82 lb/ 37.2 kg), plus the weight of the
rackmounting hardware, and the weight of any other
installed devices.
Vertical space requirements
Each server requires four rack units (7.0 inch/ 17.78 cm)
of vertical space for rack installation. A 72-inch (184-cm)
Sun cabinet ships with a power sequencer so it can
nominally hold up to eight servers (with a power
sequencer there are 36 rack units of usable space).
However, because of electrical power issues, the actual
maximum of systems per rack is six.
Doors and panels
Anti-tip protection
If you are using a Sun StorEdge Expansion Cabinet, you can
remove the front and back doors and the side panels to
increase access to the server. Otherwise, see the instructions
provided with the cabinet.
The cabinet must be bolted securely to the floor or equipped
with two sturdy and extendable anti-tip legs. You must
prevent the cabinet from tilting forward when one or more
servers or devices are fully extended out the front of the
cabinet.
52 Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
TABLE A-4 4-Post Cabinet Requirements (Continued)
Cabinet Feature
Requirement
Airflow
The server operating airflow is 92 cfm, regardless
of ambient air and altitude. This airflow provides
appropriate cooling up to 104o F (40o C) and 10,000
feet (3000 meters).
For proper ventilation of the server, the front and back
doors must comply with the following minimum open area
requirements.
• 60 percent of the area of the front door that is directly in
front of the server must be open.
• 63 percent of the area of the back door that is directly
behind the server must be open.
• Maintain a minimum of 1.5 inches (3.8 cm) clearance
between the server and any front or back doors.
If the doors of the cabinet do not meet the open area
requirements, remove the door or doors that do not comply.
Vertical mounting rails
The cabinet must have two pairs of vertical mounting rails
(one pair in front, one pair in back) that conform to the EIA
(RETMA) standard for mounting hole spacing.
Left-side-to-right-side rail spacing (mounting hole center to
mounting hole center) for front and back rails must be 17.72
inches (45 cm).
Front-to-back rail spacing must be at least 23 inches (58.42
cm) and not more than 34.5 inches (87.63 cm) from the
outside face of the front rail to the outside face of the back
rail.
Front and back vertical rail mounting faces must be parallel
with each other and with the front plane of the rack.
EMI shielding
Electromagnetic interference (EMI) shielding requirements
are met by the system chassis and metal side panels, which
remain in place when the server is rackmounted.
Minimum service access
Fire containment
An area not less than 3 feet (1 meter) deep and
6 feet (2 meters) wide must be available in front of
the cabinet, for installation and service access.
The cabinet must meet Underwriters Laboratories, Inc., and
TUV Rheinland of N.A. requirements for fire containment.
Appendix A
Background and Reference
53
Download from Www.Somanuals.com. All Manuals Search And Download.
54 Sun Fire V440 Server Installation Guide • July 2003
Download from Www.Somanuals.com. All Manuals Search And Download.
|