Planning Information
Integrated Electric Fryer Module
M O D E L I F 1 5 / S
Low profile lid
Hidden 2600-watt
heating element
Model IF15/S
Classic Stainless Steel
Illuminated electronic
touch controls
Graduated
control lighting
Deep drawn pan
Digital temperature
readout
Location of
rating plate
To round out your options for the ideal kitchen, you
must have a fryer to choose from and Wolf offers a
great option that the market has never seen. Dinner
specialties that you never tried before will be at your
fingertips when your client uses this module.
The Wolf Model IF15/S 15" (381)
integrated fryer module is available in the
classic stainless steel finish.
The accurate temperature control will enable your
customer to seal in that great flavor of the food
without absorbing any unnecessary grease. In addition,
the extremely deep fryer will enable you to handle large
portions of small items or a whole chicken.
Let Wolf, the corporate companion and kitchen soul
mate of Sub-Zero, fuel your passion for cooking and
kitchen design.
Dimensions in parentheses are in
millimeters unless otherwise specified.
1
7/06
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning Information
Integrated Electric Fryer Module
M O D E L I F 1 5 / S
S P E C I F I C A T I O N S
Overall Width
15" (381)
131/2" (343)
21" (533)
Overall Height
Overall Depth
Model IF15/S
Classic Stainless Steel
Countertop Cut-Out Width
Countertop Cut-Out Depth
Minimum Cabinet Depth
Minimum Height Clearance
Heating Element
14" (356)
191/4" (489)
223/4" (578)
131/2" (343)
2600 W
T R I M F I N I S H
Classic Stainless Steel
IF15/S
Electrical Supply Requirements
240/208 V AC, 60 Hz
15 amp dedicated circuit
V E N T I L A T I O N O P T I O N S
30" (762) Cooktop or Pro wall
hood or liner
Conduit
4 ft (1.2 m) flexible 3-wire
Electrical Rating
2.6 kW at 240 V
1.9 kW at 208 V
36" (914) Cooktop or Pro island
hood
Shipping Weight
30 lbs (14 kg)
For additional information, refer to the
Wolf Cooktop Ventilation or Pro
Ventilation sections of our website,
wolfappliance.com.
Special Note
Module can be installed in combination
with other cooktops or modules
Specifications are subject to change without notice.
A C C E S S O R I E S
Filler strip
Accessories are available through your
Wolf dealer. To obtain local dealer
information, visit the Locator section of
our website, wolfappliance.com.
Dimensions in parentheses are in
millimeters unless otherwise specified.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning Information
Integrated Electric Fryer Module
M O D E L I F 1 5 / S
I N S T A L L A T I O N S P E C I F I C A T I O N S
33" (838) RECOMMENDED
CABINET WIDTH
13" max
(330)
30" (762)
18"
7"*min (178)
CUT-OUT TO
COUNTERTOP TO
COMBUSTIBLE
MATERIALS
(457)
14" (356)
COMBUSTIBLE COOKTOP CUT-OUT
1
19 /4" (489)
2"**
1
(64) COOKTOP CUT-OUT
DEPTH
2 /2"min
MATERIALS
(BOTH SIDES)
WIDTH
ABOVE COOKTOP
(64)
3
3
1
12 /8"
12 /8"
13 /2"
(314)
(314)
(343)
5
7 /8"
6"
DRAIN OUTLET
LOCATION
(194)
(152)
36" (914)
STANDARD
FLOOR TO
COUNTERTOP
HEIGHT
DRAIN OUTLET
LOCATION
15"
E
(381)
15"
(381)
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457)
recommended cabinet width for installation of single 15" (381) cooktop or module. NOTE: Fryer module must be installed in a base cabinet with
access to manual valve at base of unit to drain oil into heat resistant receptacle. *Minimum clearance from both side edges of cooktop cut-out
to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up
to 18" (457) above countertop.
14" (356)
COOKTOP CUT-OUT
WIDTH
1
19 /4" (489)
COOKTOP
CUT-OUT DEPTH
1
2 /2"min
(64)
FRONT OF COUNTERTOP
D I M E N S I O N S
Countertop Cut-Out Width
Recommended Cabinet Width
Countertop Cut-Out Depth
Minimum Cabinet Depth
Location of Electrical
14" (356)
33" (838)
191/4" (489)
223/4" (578)
Within shaded area
See Installation Instructions shipped with unit for detailed specifications.
Dimensions in parentheses are in
millimeters unless otherwise specified.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning Information
Integrated Electric Fryer Module
M O D E L I F 1 5 / S
I N S T A L L A T I O N N O T E S
Refer to the illustrations and specifications
for overall dimensions, cut-out dimensions and
installation specifics.
IMPORTANT NOTE: Wolf does not recommend
the use of downdraft ventilation with the inte-
grated fryer module.
Wolf recommends using 33" (838) wide
cabinets for installation of two 15" (381)
modules side by side. An 18" (457) wide
cabinet is recommended for installation of a
single 15" (381) cooktop or module.
The Wolf integrated fryer module requires a
separate, grounded 3-wire 240/208 V AC, 60
Hz, 15 amp service with its own circuit breaker.
The unit is provided with a 4' (1.2 m) flexible
3-wire conduit for connection at the electrical
supply. Locate electrical within the shaded area
shown in the Installation illustration on page 4.
IMPORTANT NOTE: Review specific installation
instructions for product to product capabilities
You must follow all National Electrical Code
regulations. In addition, be aware of local codes
and ordinances when installing your service.
When multiple cooktops or modules are
installed side by side, refer to the countertop
cut-out dimensions on page 6.
The integrated fryer module must be
installed in a base cabinet with access to the
bottom of the unit to drain the oil through a
manual valve. The consumer must supply a
heat resistant bucket to accept the drained oil.
Refer to the Installation illustration on page 4
for location of the drain outlet.
This fryer module must be installed at least
15" (381) away from any open flame
cooking device. The open flame may cause
ignition of oil.
Refer to the installation instructions
shipped with each Wolf product for detailed
specifications.
This fryer module must be installed at least
15" (381) away from a Wolf steamer
module, as contact between water and hot
oil may cause burns from steam and hot oil.
This cooktop is intended for indoor use only.
A Wolf Cooktop or Pro ventilation hood is
recommended. When installing a ventilation
hood, refer to the specific requirements of the
hood for the minimum dimension to countertop.
Also refer to Ventilation Recommendations in
the Cooktop Ventilation or Pro Ventilation
sections of our website, wolfappliance.com.
Dimensions in parentheses are in
millimeters unless otherwise specified.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Planning Information
Integrated Electric Fryer Module
M O D E L I F 1 5 / S
I N T E G R A T E D M O D U L E S —
M U LT I P L E U N I T I N S T A L L A T I O N
With Wolf's integrated modules, you have the
ultimate in customization. You can create your
own design by mixing and matching the various
components within this system. And when you
couple these modules with other cooktops
within the Wolf inventory you and your client will
truly understand freedom of choice.
IMPORTANT NOTE: Where multiple cooktops
and/or modules are installed side by side, each
unit must have its own separate recommended
electrical circuit. When multiple gas cooktops
and/or modules are installed next to one
another, they can receive their gas supply from a
common line. However, each unit must have its
own regulator installed between the mainline
and the cooktop or module.
Some Wolf integrated modules can be installed
together or with a 30" (762) or 36" (914)
cooktop. When multiple units are installed side
by side, the cut-out dimensions that are shown
in the illustration are derived by adding 11/4" (32)
additional space for each additional unit, to give
you your total cut-out width. Refer to the illus-
tration below for countertop cut-out dimensions
for installation of multiple cooktops.
When two or more cooktops or modules are
installed together, an integrated module filler
strip is recommended. Contact your Wolf dealer
for information on this accessory component.
For electrical requirements, additional specifica-
tions and installation limitations, refer to the
Installation Notes on page 5.
IMPORTANT NOTE: Refer to the pages for each
specific integrated module for installation
limitations.
IMPORTANT NOTE: Review specific installation
instructions for product to product capabilities.
3
59 /4
"
(1518) FOUR MODULES WIDTH OR
1
59 /2 (1511) 30" COOKTOP AND TWO MODULES OR
"
1
50 /4
"
(1276) 36" COOKTOP AND ONE MODULE
1
44 /2
"
(1130) THREE MODULES WIDTH OR
(1124) 30" COOKTOP AND ONE MODULE
1
44 /4
"
1
29 /4 (743)
"
TWO MODULES WIDTH
1
14"
(356)
19 /4"
(489)
CUT-OUT
WIDTH
CUT-OUT
DEPTH
1
(64)
2 /2"min
FRONT OF COUNTERTOP
Countertop cut-out dimensions for installation of multiple cooktop units.
Dimensions in parentheses are in
millimeters unless otherwise specified.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
|