Sub Zero Fryer IF15 S User Manual

Planning Information  
Integrated Electric Fryer Module  
M O D E L I F 1 5 / S  
Low profile lid  
Hidden 2600-watt  
heating element  
Model IF15/S  
Classic Stainless Steel  
Illuminated electronic  
touch controls  
Graduated  
control lighting  
Deep drawn pan  
Digital temperature  
readout  
Location of  
rating plate  
To round out your options for the ideal kitchen, you  
must have a fryer to choose from and Wolf offers a  
great option that the market has never seen. Dinner  
specialties that you never tried before will be at your  
fingertips when your client uses this module.  
The Wolf Model IF15/S 15" (381)  
integrated fryer module is available in the  
classic stainless steel finish.  
The accurate temperature control will enable your  
customer to seal in that great flavor of the food  
without absorbing any unnecessary grease. In addition,  
the extremely deep fryer will enable you to handle large  
portions of small items or a whole chicken.  
Let Wolf, the corporate companion and kitchen soul  
mate of Sub-Zero, fuel your passion for cooking and  
kitchen design.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
1
7/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Integrated Electric Fryer Module  
M O D E L I F 1 5 / S  
S P E C I F I C A T I O N S  
Overall Width  
15" (381)  
131/2" (343)  
21" (533)  
Overall Height  
Overall Depth  
Model IF15/S  
Classic Stainless Steel  
Countertop Cut-Out Width  
Countertop Cut-Out Depth  
Minimum Cabinet Depth  
Minimum Height Clearance  
Heating Element  
14" (356)  
191/4" (489)  
223/4" (578)  
131/2" (343)  
2600 W  
T R I M F I N I S H  
Classic Stainless Steel  
IF15/S  
Electrical Supply Requirements  
240/208 V AC, 60 Hz  
15 amp dedicated circuit  
V E N T I L A T I O N O P T I O N S  
30" (762) Cooktop or Pro wall  
hood or liner  
Conduit  
4 ft (1.2 m) flexible 3-wire  
Electrical Rating  
2.6 kW at 240 V  
1.9 kW at 208 V  
36" (914) Cooktop or Pro island  
hood  
Shipping Weight  
30 lbs (14 kg)  
For additional information, refer to the  
Wolf Cooktop Ventilation or Pro  
Ventilation sections of our website,  
wolfappliance.com.  
Special Note  
Module can be installed in combination  
with other cooktops or modules  
Specifications are subject to change without notice.  
A C C E S S O R I E S  
Filler strip  
Accessories are available through your  
Wolf dealer. To obtain local dealer  
information, visit the Locator section of  
our website, wolfappliance.com.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Integrated Electric Fryer Module  
M O D E L I F 1 5 / S  
I N S T A L L A T I O N S P E C I F I C A T I O N S  
33" (838) RECOMMENDED  
CABINET WIDTH  
13" max  
(330)  
30" (762)  
18"  
7"*min (178)  
CUT-OUT TO  
COUNTERTOP TO  
COMBUSTIBLE  
MATERIALS  
(457)  
14" (356)  
COMBUSTIBLE COOKTOP CUT-OUT  
1
19 /4" (489)  
2"**  
1
(64) COOKTOP CUT-OUT  
DEPTH  
2 /2"min  
MATERIALS  
(BOTH SIDES)  
WIDTH  
ABOVE COOKTOP  
(64)  
3
3
1
12 /8"  
12 /8"  
13 /2"  
(314)  
(314)  
(343)  
5
7 /8"  
6"  
DRAIN OUTLET  
LOCATION  
(194)  
(152)  
36" (914)  
STANDARD  
FLOOR TO  
COUNTERTOP  
HEIGHT  
DRAIN OUTLET  
LOCATION  
15"  
E
(381)  
15"  
(381)  
NOTE: Application shown allows for installation of two 15" (381) modules side-by-side with 33" (838) recommended cabinet width. 18" (457)  
recommended cabinet width for installation of single 15" (381) cooktop or module. NOTE: Fryer module must be installed in a base cabinet with  
access to manual valve at base of unit to drain oil into heat resistant receptacle. *Minimum clearance from both side edges of cooktop cut-out  
to combustible materials up to 18" (457) above countertop. **Minimum clearance from rear edge of cooktop cut-out to combustible materials up  
to 18" (457) above countertop.  
14" (356)  
COOKTOP CUT-OUT  
WIDTH  
1
19 /4" (489)  
COOKTOP  
CUT-OUT DEPTH  
1
2 /2"min  
(64)  
FRONT OF COUNTERTOP  
D I M E N S I O N S  
Countertop Cut-Out Width  
Recommended Cabinet Width  
Countertop Cut-Out Depth  
Minimum Cabinet Depth  
Location of Electrical  
14" (356)  
33" (838)  
191/4" (489)  
223/4" (578)  
Within shaded area  
See Installation Instructions shipped with unit for detailed specifications.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Integrated Electric Fryer Module  
M O D E L I F 1 5 / S  
I N S T A L L A T I O N N O T E S  
Refer to the illustrations and specifications  
for overall dimensions, cut-out dimensions and  
installation specifics.  
IMPORTANT NOTE: Wolf does not recommend  
the use of downdraft ventilation with the inte-  
grated fryer module.  
Wolf recommends using 33" (838) wide  
cabinets for installation of two 15" (381)  
modules side by side. An 18" (457) wide  
cabinet is recommended for installation of a  
single 15" (381) cooktop or module.  
The Wolf integrated fryer module requires a  
separate, grounded 3-wire 240/208 V AC, 60  
Hz, 15 amp service with its own circuit breaker.  
The unit is provided with a 4' (1.2 m) flexible  
3-wire conduit for connection at the electrical  
supply. Locate electrical within the shaded area  
shown in the Installation illustration on page 4.  
IMPORTANT NOTE: Review specific installation  
instructions for product to product capabilities  
You must follow all National Electrical Code  
regulations. In addition, be aware of local codes  
and ordinances when installing your service.  
When multiple cooktops or modules are  
installed side by side, refer to the countertop  
cut-out dimensions on page 6.  
The integrated fryer module must be  
installed in a base cabinet with access to the  
bottom of the unit to drain the oil through a  
manual valve. The consumer must supply a  
heat resistant bucket to accept the drained oil.  
Refer to the Installation illustration on page 4  
for location of the drain outlet.  
This fryer module must be installed at least  
15" (381) away from any open flame  
cooking device. The open flame may cause  
ignition of oil.  
Refer to the installation instructions  
shipped with each Wolf product for detailed  
specifications.  
This fryer module must be installed at least  
15" (381) away from a Wolf steamer  
module, as contact between water and hot  
oil may cause burns from steam and hot oil.  
This cooktop is intended for indoor use only.  
A Wolf Cooktop or Pro ventilation hood is  
recommended. When installing a ventilation  
hood, refer to the specific requirements of the  
hood for the minimum dimension to countertop.  
Also refer to Ventilation Recommendations in  
the Cooktop Ventilation or Pro Ventilation  
sections of our website, wolfappliance.com.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Planning Information  
Integrated Electric Fryer Module  
M O D E L I F 1 5 / S  
I N T E G R A T E D M O D U L E S —  
M U LT I P L E U N I T I N S T A L L A T I O N  
With Wolf's integrated modules, you have the  
ultimate in customization. You can create your  
own design by mixing and matching the various  
components within this system. And when you  
couple these modules with other cooktops  
within the Wolf inventory you and your client will  
truly understand freedom of choice.  
IMPORTANT NOTE: Where multiple cooktops  
and/or modules are installed side by side, each  
unit must have its own separate recommended  
electrical circuit. When multiple gas cooktops  
and/or modules are installed next to one  
another, they can receive their gas supply from a  
common line. However, each unit must have its  
own regulator installed between the mainline  
and the cooktop or module.  
Some Wolf integrated modules can be installed  
together or with a 30" (762) or 36" (914)  
cooktop. When multiple units are installed side  
by side, the cut-out dimensions that are shown  
in the illustration are derived by adding 11/4" (32)  
additional space for each additional unit, to give  
you your total cut-out width. Refer to the illus-  
tration below for countertop cut-out dimensions  
for installation of multiple cooktops.  
When two or more cooktops or modules are  
installed together, an integrated module filler  
strip is recommended. Contact your Wolf dealer  
for information on this accessory component.  
For electrical requirements, additional specifica-  
tions and installation limitations, refer to the  
Installation Notes on page 5.  
IMPORTANT NOTE: Refer to the pages for each  
specific integrated module for installation  
limitations.  
IMPORTANT NOTE: Review specific installation  
instructions for product to product capabilities.  
3
59 /4  
"
(1518) FOUR MODULES WIDTH OR  
1
59 /2 (1511) 30" COOKTOP AND TWO MODULES OR  
"
1
50 /4  
"
(1276) 36" COOKTOP AND ONE MODULE  
1
44 /2  
"
(1130) THREE MODULES WIDTH OR  
(1124) 30" COOKTOP AND ONE MODULE  
1
44 /4  
"
1
29 /4 (743)  
"
TWO MODULES WIDTH  
1
14"  
(356)  
19 /4"  
(489)  
CUT-OUT  
WIDTH  
CUT-OUT  
DEPTH  
1
(64)  
2 /2"min  
FRONT OF COUNTERTOP  
Countertop cut-out dimensions for installation of multiple cooktop units.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser Telephone MM 60 iPhone User Manual
Sharp Portable Multimedia Player MX B200 User Manual
Sony Car Stereo System CDX 454XRF User Manual
Sony DVR HVR A1P User Manual
Sony Stereo Receiver STR DV10 User Manual
Southbend Convection Oven 536A User Manual
Sparky Group Drill BR 100E User Manual
Sprint Nextel Cell Phone MOTOKRZRTM User Manual
Stiga Lawn Mower 53 SE COMBI User Manual
Sunrise Medical Mobility Aid Breezy 100 User Manual