Linea
Balanced Flue Convector Fire
Instructions for Use,
Installation and Servicing
For use in GB, IE (Great Britain and Eire)
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to
obtain the translated instructions and in some cases the appliance will require modification. Contact Gazco for further information.
IMPORTANT
Do not attempt to burn rubbish in this appliance. This appliance must only be operated with the glass door secured firmly in
position. The front casing of this appliance will become hot whilst in operation, it is therefore recommended that a suitable
guard should be used for the protection of young children, the elderly or infirm.
Please read these Instructions carefully before installation or use.
Keep them in a safe place for future reference and when servicing the fire.
The commissioning sheet found at the end of the Users Sections of these instructions should be completed by the Installer.
PR0731 Issue 9 (September 2007)
Download from Www.Somanuals.com. All Manuals Search And Download.
APPLIANCE COMMISSIONING CHECKLIST
IMPORTANT NOTICE
Explain the operation of the appliance to the end user, hand the completed instructions to them for safe keeping,
as the information will be required when making any guaranteed claims.
FLUE CHECK
PASS
FAIL
1.
2.
3.
Flue is correct for appliance
Flue flow test N/A
Spillage test N/A
GAS CHECK
1.
2.
3.
Gas soundness & let by test
Standing pressure test
mb
mb
Appliance working pressure (on High Setting)
NB All other gas appliances must be operating on full
3
4.
5.
6.
Gas rate
m /h
Does ventilation meet appliance requirements N/A
Has the remote hand set been tuned to the control box
YES
NO
DEALER AND INSTALLER INFORMATION
Dealer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contact No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Date of Purchase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Model No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Serial No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gas Type. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation Company . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Engineer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Contact No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Corgi Reg No.. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Date of Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
This product is guaranteed for 2 years from the date of installation, as set out in the terms and conditions of sale between Gazco and your
local Gazco dealer. This guarantee will be invalid, to the extent permitted by law, if the above Appliance Commissioning Checklist is not
fully completed by the installer and available for inspection by a Gazco engineer. The guarantee will only be valid during the second year,
to the extent permitted by law, if the annual service recommended in the Instructions for Use has been completed by a Corgi registered
engineer, and a copy of the service visit report is available for inspection by a Gazco engineer.
Download from Www.Somanuals.com. All Manuals Search And Download.
3
USER INSTRUCTIONS
The pilot and main burner ignite and the remote is now in
1. GENERAL
Manual Mode. In ‘MANUAL MODE’ you can:
• turn on the main burner
• regulate the flame from low to high and back
• turn off the burner leaving just the pilot burning
In ‘TEMP MODE’ you can:
• set the room temperature so the thermostat in the
remote automatically maintains that temperature
1.1 A competent person must carry out installation and
servicing.
1.2 In all correspondence, please quote the appliance type and
serial number, which can be found on the data badge
located on a plate under the control valve.
1.3 Ensure that curtains are not positioned above the appliance
and there is at least 300mm between the sides of the
appliance and any curtains.
1.4 If any cracks appear in the glass panel do not use the
appliance until the panel has been replaced.
In ‘TIMER MODE’ the fire:
• turns on and off according to the set time periods
• automatically regulates the room temperature during the
set periods
1.5 If, for any reason, the flue has to be removed from the
appliance, the seals must be replaced in the inner spigot.
1.6 Do not obstruct the flue terminal in any way, i.e. by
planting flowers, trees, shrubs etc in the near vicinity, or by
leaning objects up against the terminal guard.
1.7 Do not use a garden sprinkler or hose near the terminal.
1.8 Do not stand or place objects on the terminal guard as this
will deform it.
NOTE: Wh E N O p E r a T i N g T h E f i r E iN TE m p O r Ti m E r m O d E ,
T h E p i l O T r E m a i N s liT a N d T h E f i r E T h E N a u T O m a T i c a l l y
s W i T c h E s O N a T p r O g r a m m E d T i m E s T O b r i N g T h E r O O m T O
T h E s E T T E m p E r a T u r E W h E T h E r O r N O T y O u a r E iN T h E r O O m .
NEVER LEAVE ANY COMBUSTIBLE MATERIALS WITHIN 1
METRE OF THE FRONT OF THE APPLIANCE.
2.1 SWITCHING BETWEEN MODES
This product is guaranteed for 2 years from the date of
installation, as set out in the terms and conditions of sale
between Gazco and your local Gazco dealer. Please consult
with your local Gazco dealer if you have any questions. In
all correspondence always quote the Model Number and
Serial Number.
• Press the SET button to change to Manual Operation
• Press again to change to Temperature Mode
• Keep pressing to run through all operating modes. These
are:
•
•
•
•
MAN
DAY TEMP
NIGHT TEMP
TIMER
2. LIGHTING THE LINEA
There are two ways of lighting the Linea:
• by thermostatic remote control, see 2A
• using the fire’s touch pad, see 2B
and back to MAN
NOTE: MAN mode can also be reached by pressing
either the UP or DOWN arrow
2A - THERMOSTATIC and TIMER REMOTE CONTROL
2.2 MAN MODE
• Press both the UP arrow and immediately press the OFF
button to light the appliance. You hear a click as the fire
begins the ignition process , (up to 30 seconds)
1
• Press the OFF button to turn the appliance off
INCREASING TEMPERATURE
• Press the UP arrow once to increase flame height one
stage
• Press and hold the UP arrow to increase to maximum
DECREASING TEMPERATURE
AR1883
• Press the DOWN arrow once to decrease flame height
one stage
• Press and hold the DOWN arrow to decrease to
Turning the Linea On
Your remote can control the gas fire from pilot ignition
through to shut down.
minimum
At the lowest point the fire goes to ‘standby mode’ (only
pilot lit)
To turn the fire on:
NOTE: While pressing a button a symbol indicating
transmission appears on the display. The receiver
confirms transmission with an acoustic signal.
• Press the OFF button and the UP arrow simultaneously
Download from Www.Somanuals.com. All Manuals Search And Download.
4
USER INSTRUCTIONS
Turning the Linea Off
• Press the Off button to extinguish the pilot
2.3 TEMP MODE
• Press the SET button again to scroll past the settings for
P1 and P1
With the time still flashing:
• Press the UP arrow to alter the hour
• Press the DOWN arrow to alter the minutes
The display shows the current room temperature.
To increase or decrease the fire’s output:
Once all four times are set press the OFF button or simply
wait to complete programming.
• Press the SET button to select either the DAY TEMP
or the NIGHT TEMP mode by briefly pressing the
SET button
• Hold the SET button until the TEMP display flashes and
2.5 LOW BATTERY
then let go
“BATT” is displayed on the remote when its batteries need
replacement.
• Set the desired temperature with the UP and DOWN
arrows. (Minimum temperature 5C, maximum 30C or
fahrenheit)
2.6 SETTING THE TIME
• Press the OFF button to stop the display flashing or wait
• Simultaneously press the up and down arrow buttons
to return to TEMP mode.
• Press the up arrow to set the hour and the down arrow
NOTE: If you set a temperature that is beneath the
current room temperature, the fire automatically
switches to OFF.
to set the minutes
• Press OFF to return to the manual mode or simply wait
NOTE: If you would like the Night temperature control to
turn off then decrease the temperature until [---] is
displayed.
2.7 SETTING THE °C/24 HOUR OR °F/12 HOUR CLOCK
• Press OFF and the down arrow until the display changes
from °C/24 hour clock to °F/12 hour clock and vice
versa.
2.4 TIMER MODE
If the remote is removed, lost or damaged, signals
transmitted to the receiver cease. Your fire will go to
standby (pilot) mode after 6 hours.
There are two programmable settings you can make over a
24 hour period, P1 and P2
P1 +
P1 +
P2 +
P2 +
= Start Timed Setting 1
= End of Timed Setting 1
= Start Timed Setting 2
= End of Timed Setting 2
2B TOUCH PAD CONTROL
2.4.1 P1 - Program 1 for a Timed Setting
2
• Press the SET button until the TIMER mode is displayed
• Hold the SET button. The displays flashes the current
time for P1. While the time displayed is flashing you can
alter the hours and minutes set.
To set the time your fire first lights, change the Start Timed
Setting for P1
.
• Press the UP arrow to alter the hour
AR1885
• Press the DOWN arrow to alter the minutes
in 10 minute increments
• Press SET again to move to the End of Timed Setting,
P1. The display shows the current setting for P1
This is the time your Linea first shuts down:
• Press the ON-OFF button to light the appliance, (up to
30 seconds)
• Press the UP button to increase the flame height
• Press the UP arrow to alter the hour
• Press the DOWN arrow to alter the minutes
2.4.2 P2 - Program 2 for a Timed Setting
• Press the DOWN button to decrease the flame height. At
the lowest point it goes to ‘standby mode’, (only pilot
lit)
• Press the ON-OFF button to turn the appliance off
Use the same steps outlined in 2.4.1 to change the setting
for P2.
If you have already set P1 and want to alter the setting for
P2 only:
• Press the SET button until TIMER mode is displayed
• Hold the SET button until the display flashes the
current time for P1
Download from Www.Somanuals.com. All Manuals Search And Download.
5
USER INSTRUCTION
EMERGENCY SHUT OFF
5
If the batteries fail during use of the fire:
• Move the emergency shut off switch to the OFF (O)
position
This emergency switch is located behind the slotted lower
panel on the underside of the appliance:
3
Underside of appliance
Access to switch
AR1339
3.4 Use a damp cloth and warm soapy water. Ensure the glass is
dry before re-assembling.
3.5 Ensure that the fibreglass seal on the firebox is intact then
hook the location tabs over the hooks on the top of the
firebox. Replace the nine screws working from the top
down, three long ones in the bottom holes. Tighten the
screws evenly.
AR1341
• Use a ball point pen or narrow screwdriver to push the
rocker switch to the OFF (O) position, Diagram 4
NEVER OPERATE THE APPLIANCE WHEN THE GLASS
PANEL IS REMOVED OR BROKEN.
4
Emergency
Shut Off
4. FLAME FAILURE DEVICE
4.1 This is a safety feature incorporated on this appliance which
automatically switches off the gas supply if the pilot goes
out and fails to heat the thermocouple.
5. RUNNING IN
AR1961
5.1 The surface coating on the ceramic panel used in your
GAZCO fire will "burn off" during the first few hours of use
producing a harmless and temporary odour. This will
disappear after a short period of use. If the odour persists,
ask your installer for advice.
(This switch is set to be ON (|) during normal operation
and must remain ON)
3. CLEANING THE LINEA
6. SERVICING
ENSURE THE APPLIANCE IS COLD BEFORE PROCEEDING.
3.1 The outside casing of the Linea should be cleaned using a
damp cloth.
3.2 To clean the glass panel, remove the decorative front as
detailed in the instructions supplied with front.
3.3 Remove the glass panel by unscrewing the nine pozidrive
screws, Diagram 5
6.1 The fire must be serviced every 12 months by a qualified
Gas Engineer. In all correspondence always quote the
Model number and the Serial number which may be found
on the data badge.
7. VENTILATION
7.1 This appliance requires no additional ventilation.
Download from Www.Somanuals.com. All Manuals Search And Download.
6
USER INSTRUCTION
8. INSTALLATION DETAILS
11. FIRE WILL NOT LIGHT
8.1 To assist in any future correspondence, your installer should
have completed the commissioning sheet at the front of this
book, this records the essential installation details of the
appliance. In all correspondence always quote the Model
number and Serial number.
11.1 If you cannot light the Linea:
• Check that the emergency shut off switch is in the ON
(1) position, see Section 2, Emergency Shut Off
• Check and change the batteries in the remote handset
• Check and change the appliance batteries, Section 10.
Consult your Gazco dealer if the Linea still does not light.
9. HOT SURFACES
9.1 Parts of this appliance become hot during normal use. It is
therefore recommended that a suitable fire guard be used
for protection of young children and the infirm. Indeed, all
parts of the appliance should be treated as a 'working
surface' except for the control touch pad area and access
panel (Designio version only).
10. BATTERY REPLACEMENT
10.1 If the Linea is fitted with a Designio front, access to the
batteries can be achieved by simply dropping the lower
front access cover.
10.2 If the Linea is fitted with a Plano, Vetro or Steel front,
access to the batteries can be achieved through the access
hole in the casing below the unit, Diagram 6.
6
AR1341
10.3 Replace the batteries with four ‘AA’ size cells, ensuring they
are in the correct orientation as shown in the diagram in the
base of the plastic holder.
10.4 Once the batteries have been replaced, carefully locate the
battery holder back into its cradle in the base of the
appliance.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
TECHNICAL SPECIFICATION
COVERING THE FOLLOWING MODELS
8651EC P8651EC
Gas
Gas
Working
Gas Rate
m3/h
Input kW (Gross)
Nox
Class
Model
Aeration
2 x 8mm
Injector
Country
CAT.
Type
Pressure
High
5.25
5.25
Low
3.5
3.5
Linea NG
Linea LPG
I
Natural (G20)
Propane (G31)
20mbar
37mbar
1.7
1.2
0.50
0.20
4
4
GB, IE
GB, IE
2H
1 x 7.5mm
2 x 10mm
I
3P
Efficiency Class I
Flue Outlet Size 100 Ø / 152mm Ø
Gas Inlet Connection Size 8mm Ø
Wall Thickness - Minimum = 100mm (4") Maximum = 500mm
Linea Replacement Batteries - 4 x 'AA' Cells
Handset Replacement Batteries - 1 X 9v 'PP3' Cell
PACKING CHECKLIST
Qty
Description
1
1
1
1
Linea assembly including fixing bracket
Flue Pipe
Terminal Guard
Remote Hand Set
1
Terminal Guard Fixing Kit Containing:
1
4 Wood Screws 1 / ”
4
4 Red Rawlplugs
1
Linea Fixing Kit Containing:
AR1330
1
4 Wood Screws 2 / ”
2
4 Brown Rawlplugs
1 Aluminium Tape
1 Sealing Ring
4 x “AA” Cells
1 x 9v 'PP3' Cell
1
Instruction Manual
AR1331
Download from Www.Somanuals.com. All Manuals Search And Download.
8
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
2
1. FLUE AND CHIMNEY REQUIREMENTS
NOTE: This appliance can only be installed in
conjunction with the flue supplied.
1.1 The flue must be sited in accordance with BS5440: Part 1
(latest edition). See diagram 1.
1.2 Any terminal which is less than 2 metres above any access
(level ground, balcony or above a flat roof to which people
have access) is to be fitted with a guard.
1.3 The flue must be securely fixed and fire precautions
followed in accordance with local and national codes of
practice.
AR0630
1.4 The horizontal terminal can be reduced in size. See
diagram 2.
1
Download from Www.Somanuals.com. All Manuals Search And Download.
9
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
TIMBER FRAMED BUILDINGS
3. VENTILATION
1.5 It will be necessary to provide additional clearance when
the flue passes through a wall containing any combustible
materials so as to prevent a fire hazard.
3.1 This appliance requires no additional ventilation.
1.6 The hole through which the flue will pass, must have a steel
sleeve which is positioned so that an air gap of at least
25mm is maintained between the outer surface of the flue,
and any part of the sleeve.
1.7 For further guidance on the installation of gas appliances in
timber framed buildings, contact your local buildings control
authority.
4. APPLIANCE LOCATION
IMPORTANT: DO NOT OBSTRUCT THE TOP AND BOTTOM
SLOTS IN THE LINEA OUTER CASE, THESE MUST BE
UNOBSTRUCTED. DO NOT RECESS THIS APPLIANCE
INTO A WALL, IT MUST BE SURFACE MOUNTED ON A
FLAT WALL USING THE WALL MOUNTING BRACKET
SUPPLIED.
2. GAS SUPPLY
2.1 Before installation, ensure that the local distribution
conditions (identification of the type of gas and pressure)
and the adjustment of the appliance are compatible.
2.2 Ensure that the gas supply is capable of delivering the
required amount of gas and is in accordance with the rules
in force.
4.1 This appliance does not require a hearth. It can only be
fitted on an outside wall with suitable clearances for the flue
terminal and guard (if required). As detailed in diagram 1.
4.2 All minimum clearances must be complied with. See
diagram 3. These clearances are to the outside edge of the
decorative frame and are therefore dependant on the frame
chosen.
2.3 Soft copper tubing can be used to install the appliance. Soft
soldered joints can be used externally of the appliance.
2.4 This appliance is supplied complete with a factory fitted
isolation device incorporated into the inlet connection, no
further isolation device is required.
3
2.5 All supply gas pipes must be purged of any debris that may
have entered, prior to connection to the appliance.
2.6 The gas inlet is located centrally at the bottom of the
appliance. The supply pipe may be installed using one of
three alternatives.
1) By drilling a hole straight through the outside wall. There
is a cutout in the back panel of the Linea and the fixing
bracket to allow the pipe to be concealed within the
appliance.
2) Surface mounting the pipe. For this option there is a pipe
cover kit 8654. This consists of
AR1325
a) 1.4 Metre Cover
b) 2 Brackets
c) Screws and Rawlplugs
4.3 The outer dimensions of the frames and their position
relative to the flue centre of the Linea are detailed in
diagrams 4 and 5.
To fit the cover, measure the length required and cut down
accordingly. Fix the two brackets to the wall as required.
The magnets should be vertical. Fix pipe clips to the wall
and install the gas pipe. The cover can now be attached to
the magnets to cover the gas supply.
DESIGNO
4
NOTE: There are three options of cover finishes. Black,
Metallic Alloy and primed finish which allows the customer
to finish any chosen colour.
3) The gas pipe can be concealed by cutting a channel in
the wall. All current regulations must be adhered to and no
pipe joint must be concealed in the wall.
AR1326
10
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
SITE REQUIREMENTS
5
VETRO / PLANO / STEEL DIMENSIONS
AR1327
4.4 All combustible materials must be removed from behind the
appliance. See diagram 6.
6
Combustible material to be removed around centre
line of flue. Shown as shaded area
AR1328
4.5 The Linea may be mounted at any height, however, there
must be a minimum clearance of 150mm (6") between the
bottom edge of the appliance and the floor. To achieve this,
the minimum flue height for each front is shown in diagram
7.
7
MINIMUM HEIGHT OF FLUE FROM FLOOR LEVEL
VETRO / PLANO / STEEL
DESIGNIO
AR1324
Download from Www.Somanuals.com. All Manuals Search And Download.
11
INSTALLATION INSTRUCTIONS
INSTALLATION
IMPORTANT: BEFORE THE APPLIANCE CAN BE
of the flue hole and the position of four fixing holes for the
OPERATED THE REMOTE HANDSET MUST BE TUNED TO
THE CONTROL BOX SITUATED UNDER THE APPLIANCE.
IF THIS PROCEDURE IS OMITTED THE APPLIANCE CAN
ONLY BE LIT USING THE TOUCH PAD, SEE USER
INSTRUCTIONS, 2B TOUCH PAD CONTROL.
wall-fixing bracket. See diagram 2.
Note: If a Vetro, Plano or Steel decorative front has been
purchased, it will also be necessary to mark the positions of
the four fixing holes for the front.
ENSURE THAT THE APPLIANCE IS CORRECTLY ADJUSTED
FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE
COUNTRY OF USE. REFER TO DATA BADGE AND THE
TECHNICAL SPECIFICATIONS ON PAGE 8.
2
FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER
TO THE SERVICING INSTRUCTIONS.
1. SAFETY PRECAUTIONS
1.1 This appliance must be installed in accordance with the
rules in force, and used only in a sufficiently ventilated
space. Please read these instructions before installation and
use of this appliance.
AR1347
1.2 These instructions must be left intact with the user.
1.3 Do not attempt to burn rubbish on this appliance.
TAKE CARE WHEN MARKING OUT THE FLUE AS IT IS
VERY DIFFICULT TO MOVE AFTER INSTALLATION.
2.5 A 152mm (6") diameter hole is required to install the flue.
This can be achieved by either:
1.4 In your own interest, and those of safety, this appliance
must be installed by competent persons in accordance with
local and national codes of practice. Failure to install the
appliance correctly could lead to prosecution.
a) Core drill
b) Hammer and chisel
c) Drill small holes around the circumference, knock out
the centre and make good at both ends.
1.5 Keep all plastic bags away from young children.
2.6 When the hole for the flue has been completed, insert the
four brown rawplugs supplied and attach the fixing bracket
using only the top two screws. See diagram 2a.
2. INSTALLATION OF THE APPLIANCE
2.1 Remove the appliance from the box and remove the two
screws, one from either side near the top of the black
surround. This will release the wall-fixing bracket.
2a
2.2 Decide on the position of the Linea and Decorative front and
mark the intended position of the outer bottom edge of the
frame. Refer to diagram 4 and 5 in the site requirements for
overall dimensions of the decorative frames.
2.3 Having marked the position of the outer bottom edge,
position the template supplied ensuring that the line on the
wall aligns with the appropriate decorative frame bottom
edge on the template. See diagram 1.
2.4 Having ensured that the template is level, mark the centre
AR1418
1
AR1332
Download from Www.Somanuals.com. All Manuals Search And Download.
12
INSTALLATION INSTRUCTIONS
INSTALLATION
2.7 The flue can now be cut to size. Measure the thickness of
6
the wall, then deduct 12mm. This is the length required
when measuring from the line on the flue label. See
diagram 3.
3
AR1338
A
A
AR0630
DO NOT OVER TIGHTEN. DO NOT DEFORM THE REAR
OF THE APPLIANCE.
2.8 Attach the flue to the appliance and seal using the
aluminium tape. See diagram 4.
2.13 Remove the nine screws retaining the glass frame, remove
the frame and store in a safe place. See diagram 7.
4
7
AR1335
2.9 Place the sealing ring over the flue and position it up against
the rear of the appliance. See diagram 5.
AR1339
5
2.14 Remove the cardboard packaging from on top of the burner
and ensure the burner is fully engaged on the injector. Also
check the burner retention spring is located over the stud
and tab on the left hand side of the burner. See diagram 8.
8
AR1336
2.10 Fit the appliance on to the wall bracket by engaging the
arms on the bracket into the slots in the rear of the
appliance. See diagram 5.
2.11 Fit the appliance as far back as possible and refit the two
screws to secure the Linea to the wall bracket.
2.12 Fit the lower two wood screws through the rear of the
appliance and into the wall. See diagram 6 arrow A.
AR1340
Download from Www.Somanuals.com. All Manuals Search And Download.
13
INSTALLATION INSTRUCTIONS
INSTALLATION
2.15 Replace the glass frame; ensure the top of the frame is
• automatically regulates the room temperature during the
hooked on the tabs at the top of the appliance and replace
the nine screws with the three longest screws used in the
bottom fixing holes. Tighten from the top down.
set periods
TOUCH PAD CONTROL
HAVE YOU PURGED THE GAS SUPPLY?
2.16 Connect the gas supply to the isolation device using 8mm
pipe. Connect a suitable pressure gauge to the test point
and turn on the gas supply and check for leaks.
10
2.17 Light the appliance and set it to maximum. Check the
pressure corresponds to the data badge. Turn the gas off
and replace the test point screw. Turn the gas on and check
the screw for leaks.
THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE
HAS GAINED SUFFICIENT HEAT - TYPICALLY 20
MINUTES.
AR1885
3. LIGHTING THE LINEA
• Press the ON-OFF button to light the appliance, (up to
30 seconds)
• Press the UP button to increase the flame height
Note: The Emergency Shut Off switch must be in the ON
• Press the DOWN button to decrease the flame height. At
position, refer to Section 2, User Instructions.
the lowest point it goes to ‘standby mode’, (only pilot
There are two ways of lighting the Linea:
• by thermostatic remote control
• using the fire’s touchpad
lit)
• Press the ON-OFF button to turn the appliance off
4. REPROGRAMMING HANDSET/CONTROL
BOX
THERMOSTATIC REMOTE CONTROL
9
• Remove the battery cover from the handset to see the
four DIP switches, Diagram 11
11
AR1883
This remote controls the gas fire. In ‘MANUAL MODE’ you can:
• turn on the main burner
• regulate the flame from low to high and back
• turn off the burner
In ‘TEMP MODE’ you can:
• set the room temperature so the fire automatically
maintains that temperature
AR1935
In ‘TIMER MODE’ the fire:
• turns on and off according to the set time periods
14
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION INSTRUCTIONS
COMMISSIONING
Each of the four switches can be set to either one of two
positions, in any combination.
To re-code the handset:
• Change the combination of how the DIP switches are set,
Diagram 12
12
AR1936
Once the handset has a new code the control box needs to
be reprogrammed:
To access the control box see Servicing Instructions, Section
11 - Control Box.
• Press and hold the reset button on the control box until
you hear two signals. After the second longer signal:
•
Release the reset button and within 20
seconds press the DOWN button on the
handset until you hear an additional long signal
confirming the new code
5. COMMISSIONING
5.1 Complete the Commissioning Checklist at the front of this
manual covering:
• Flue checks
• Gas checks
5.2 In the unlikely event that the appliance is receiving
interferece from other electronic devices, re-programme the
handset/Control box
Download from Www.Somanuals.com. All Manuals Search And Download.
15
SERVICING INSTRUCTIONS
SERVICING / FAULT FINDING CHARTS
REPLACE BATTERIES BEFORE ATTEMPTING TO RECTIFY ANY
FAULTS.
1. SERVICING REQUIREMENTS
IF THE FIRE DOES NOT WORK, BUT HAS WORKED IN THE
PAST:
This appliance must be serviced at least once a year by a
competent person.
All tests must be serviced by best practice as described by the
current CORGI recommendations.
•
CHECK THE EMERGENCY SHUT OFF SWITCH
ON THE BOTTOM OF THE APPLIANCE IS
SWITCHED ON, SEE USER SECTION, PAGE 6
1.1 Before any tests are undertaken on the appliance:
Electronic Control Valve Fault Analysis
• Conduct a gas soundness test for the property to ensure
there are no gas leaks prior to starting work.
1.2 • Fully check the operation of the appliance
Symptom
Cause
Remedy
3 Short beeps from
control
Batteries low in
appliance
Replace appliance
batteries
Special checks
No ignition, 5 second
continuous tone (there
may be several short
beeps before)
1. On/Off switch is in 1. Move switch to
1.2.1 Clean any lint or fluff from the pilot
1.2.2 Clean away any fluff or lint from under the burner
1.2.3 Check the spark gap on the pilot is correct
• Correct any faults found during the initial tests
OFF position
2. Loose/damaged
wire
ON position
2 Check interuptor
bloack and wires
No ignition, no tone,
Receiver board
Replace receiver
motor turns slightly when damaged
operated
• Re-commission the appliance conducting the usual safety
checks
1.3 Advise the customer of any remedial action taken.
No pilot flame and
control continues to
spark
Thermocouple circuit Correct wiring
wired incorrectly
Pilot lights, control
continues to spark, value burner
1. No spark at pilot
1. Rectify spark at
pilot burner
shuts down after 10 - 30
seconds
2. Loose/damaged
wire
2. Check interrupter
and wires
Download from Www.Somanuals.com. All Manuals Search And Download.
1
6
SERVICING INSTRUCTIONS
FAULT FINDING CHARTS
Download from Www.Somanuals.com. All Manuals Search And Download.
1
7
SERVICING INSTRUCTIONS
REPLACING PARTS
2.4 Raise the burner from the slot in the bracket, pull the
burner forward and slide to the left to clear the injector.
Take care not to lose the spring.
1. GENERAL
2.5 Replace in reverse order ensuring the spring is located over
the stud on the burner and the tab on the bracket.
1.1 All principal components can be replaced without removing
the appliance from its installation, although it is essential
that the gas supply to the appliance is turned off at the
isolation device before proceeding further.
1.2 If for any reason the flue has to be removed from the
appliance, the seal must be replaced in the inner spigot.
3. PILOT UNIT
1.3 If access to the controls is restricted, the whole control
assembly and wiring loom can be removed and serviced
outside the Linea, refer to section 14 for further details.
The main frame, glass frame and main burner need only be
removed if the pilot burner is to be replaced. If only the
pilot injector, electrode or thermocouple is to be replaced
they can be accessed from under the appliance.
2. MAIN BURNER
The pilot assembly consists of four components, which can
be individually changed, these are:
2.1 Remove the front from the appliance. (Refer to the
instructions supplied with the decorative front)
2.2 Remove the glass frame, note the orientation of the screws.
The three long silver screws locate only in the bottom of the
frame. See diagram 1, arrow C.
1) Pilot burner bracket.
2) Pilot injector
3) Electrode
4) Thermocouple.
1
4. PILOT BURNER
C
4.1 Remove the main front by referring to the instructions
supplied with the decorative front.
C
4.2 Remove the glass frame from the appliance. See diagram 1
arrow C.
4.3 Remove the main burner by compressing the spring on the
lefthand side of the burner. See diagram 2. Raise the burner
forward and slide to the left to clear the injector. Take care
not to lose the spring.
C
C
C
C
4.4 Working underneath the appliance, remove the lower
panel. See diagram 3.
C
C
C
AR1338
3
2.3 Compress the burner retaining spring towards the burner.
See diagram 2.
2
AR1341
4.5 Remove the thermocouple, pilot pipe and electrode as
described in the sections 5 to 7.
4.6 Remove the two screws retaining the pilot burner. See
diagram 4.
AR1340
18
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICING INSTRUCTIONS
REPLACING PARTS
4
6
X = LPG 10
x
NG 15
AR1341
6.2 Pull the ignition lead off the electrode and undo the
retaining nut. See diagram 7.
4.7 Reassemble in reverse order and replace the pilot gasket
with a new one.
4.8 Check for gas leaks.
7
5. PILOT INjECTOR
5.1 To gain access to the pilot pipe, it is easier if the
thermocouple is removed first. To do this follow section 7.
5.2 Undo the pilot pipe from the gas valve and from under side
of the pilot burner. See diagram 5 arrow B.
5.3 Remove the pipe and the injector will drop out from the
burner. Take care not to lose or damage the injector.
5.4 To replace the injector reverse the above procedure.
5.5 Check for gas leaks.
5
B
B
AR1349
6.3 Replace with a new electrode. Do not over tighten the nut
as this could break the new component.
6.4 Replace the ignition lead and the lower panel.
7. THERMOCOUPLE
AR1993
7.1 Remove the lower panel. See diagram 6.
7.2 Disconnect the thermocouple from the gas valve. See
diagram 8 arrow C.
6. ELECTRODE
6.1 Remove the lower panel. See diagram 6.
Download from Www.Somanuals.com. All Manuals Search And Download.
19
SERVICING INSTRUCTIONS
REPLACING PARTS
8
C
9. MAGNETIC SAFETY VALVE
9.1 • Turn the gas off at the isolation device.
9.2 • Remove the lower panel, Diagram 6
9.3 • Undo the thermocouple from the interrupter block and
remove the two thermo current cables
• Unscrew the interrupter block from the back of the valve.
Diagram 10
AR1994
10
7.3 Undo the thermocouple nut in the back of the pilot burner
by half a turn. This will release the thermocouple.
7.4 When replacing the thermocouple into the pilot burner
ensure the component is pushed fully into the hole. There is
a stop on the thermocouple to set the height.
7.5 Lock the retaining nut just enough to grip the
thermocouple.
7.6 Replace the lower panel.
8. IGNITION LEAD
AR1994
8.1 Remove the lower panel and pull the ignition lead off the
electrode.
9.4 Support the valve and remove the magnetic valve retaining
nut, Diagram 11
8.2 Release the wires from the central white clip and carefully
cut the cable ties. This will release the ignition lead. See
diagram 9, Arrow B.
11
9
B
AR1994
AR1994
9.5 Reassemble in reverse order and check for gas leaks.
8.3 Replace with a new lead, replace with new cable ties and
fit the wires back into the clip.
8.4 Re-fit the panel and ensure no wires are trapped.
10. MAIN INjECTOR
10.1 Remove the lower panel. See diagram 6.
10.2 Remove the glass frame. See diagram 12 arrow C.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICING INSTRUCTIONS
REPLACING PARTS
appliance. Note the orientation of the injector on the pipe.
10.7 Reassemble in reverse order and check for gas leaks.
12
C
C
11. CONTROL BOX
C
C
11.1 Remove the lower panel, Diagram 6
11.2 Press on/off switch retaining clips in and pop put the switch.
Turn the switch to pass it through the retaining bracket.
C
C
11.3 Remove the two screws holding the control box to the
bracket. Slide the control box to the right and remove from
the bracket.
AR1338
C
C
C
11.4
• Remove the two thermo current cables by removing
the two screws, Diagram 15
• Remove the eight loom wire from the control box,
Diagram 15
10.3 Remove the main burner as described in section 2.
10.4 Remove the locknut from the injector. See diagram 13
15
Eight wire cable
13
Thermo current
cables
Touchpad
extension
cable
Battery
extension
cable
AR1345
10.5 Remove the feed pipe from the gas valve. See diagram 14.
AR1915
14
• Remove the battery extension cable, Diagram 15
• Remove the touch pad extension cable, Diagram 15
The control box can now be replaced.
11.5 After replacing the control box you may need to reprogram
the handset:
• Press and hold the reset button on the control box until
you hear two signals. After the second longer signal:
• Release the reset button and within 20
seconds
- Press the DOWN button on the handset until
you hear an additional long signal
confirming the new code
AR1994
• Refer to Section 4 of the Installation Instructions to set
new code
10.6 Remove the feed pipe with the injector attached from the
Download from Www.Somanuals.com. All Manuals Search And Download.
21
SERVICING INSTRUCTIONS
REPLACING PARTS
14.1 Remove the outer decorative front, refer to the instructions
supplied with the front. (FOR VETRO, PLANO AND STEEL
FRAMES, MAKE SURE THAT THE TOUCHPAD IS
REMOVED FROM THE HARNESS BEFORE FRAME
REMOVAL)
12. GAS VALVE
12.1 To change the gas valve:
14.2 Remove the lower panel. See diagram 6 above.
• Disconnect the inlet pipe
14.3 Disconnect the gas pipe at the isolation device. See diagram
17 arrow B.
• Disconnect the feed pipe
• Disconnect the pilot pipe
• Disconnect the thermocouple, thermo current wires and
the interrupter block
• Remove the two screws and rotate the valve to
access the front
The cable can now be removed from the valve, Diagram 16
17
16
B
AR1994
14.4 Remove the glass frame. See diagram 21 arrow C.
AR1994
18
C
C
• Reassemble in reverse order and check for leaks
C
13. CHANGING BETWEEN GAS TYPES
C
In order to change between gas types it will be necessary to
change the following items.
C
C
Main Injector
Main Burner
Pilot Injector
AR1338
C
C
C
Control Valve
Control Box
14.5 Remove the main burner as described in Section 2,
Replacing Parts
14.6 Remove the injector locknut. See diagram 19.
Thermocouple ( NG to LPG only).
LPG to NG no change).
Data Badge
14. CONTROL BRACKET ASSEMBLY
NOTE: THIS ONLY NEEDS TO BE DONE IF ACCESS IS
TO THE CONTROLS IS RESTRICTED.
Download from Www.Somanuals.com. All Manuals Search And Download.
22
SERVICING INSTRUCTIONS
REPLACING PARTS
19
AR1345
14.7 Disconnect the touch pad from the harness (DESIGNIO
FRAME ONLY)
14.8 Disconnect the ignition lead from the electrode.
14.9 Remove the thermocouple. See diagram 20 arrow C.
14.10 Remove the pilot pipe and ensure the pilot injector is kept
safe, Diagram 20, Arrow D
20
D
C
F
F
E
AR1994
14.11 Remove the injector feed pipe from the valve, Diagram 20,
Arrow E.
14.12 Remove the two screws securing the control bracket to the
appliance, Diagram 20, Arrow F
14.13 Tilt the front edge of the bracket down slightly and move
the assembly to the right. The assembly can now be lifted
clear of the appliance.
14.4 Reassemble in reverse order and check for gas leaks.
Download from Www.Somanuals.com. All Manuals Search And Download.
23
SERVICING INSTRUCTIONS
REPLACING PARTS
15. SHORT SPARES LIST
Component
NG
LPG
Propane Butane
Burner Unit
GC0104 GC0105 GC0106
Main Injector
IN0053
PI0069
PI0071
IN0052
PI0070
PI0072
Pilot Injector
Thermocouple
Control Box
GC0129
Gas Valve
GC0123
GC0092
GC0125
PI10073
CE0474
GZ3949
GC0131
GC0124
GC0126
GC0128
GC0130
EL0410
Mag Unit
IGN Lead
Spark Electrode
Ceramic Rear Panel
Window Frame Assembly
Remote Control
Interrupter Block
Thermocurrent Cable
Thermocurrent Switch Cable
Touchpad and Lead
Battery Holder
Battery Holder Cable
Control Box / Valve Cable
Burner Retention Spring
GC0127
GC0133
FA0407
Download from Www.Somanuals.com. All Manuals Search And Download.
24
SERVICE RECORDS
2ND SERVICE
1ST SERVICE
Date of Service:...........................................................................
Next Service Due:.......................................................................
Signed:........................................................................................
Dealer's Stamp/CORGI Registration Number
Date of Service:...........................................................................
Next Service Due:.......................................................................
Signed:........................................................................................
Dealer's Stamp/CORGI Registration Number
4TH SERVICE
3RD SERVICE
Date of Service:...........................................................................
Next Service Due:.......................................................................
Signed:........................................................................................
Dealer's Stamp/CORGI Registration Number
Date of Service:...........................................................................
Next ServiceDue:........................................................................
Signed:........................................................................................
Dealer's Stamp/CORGI Registration Number
6TH SERVICE
5TH SERVICE
Date of Service:...........................................................................
Next Service Due:.......................................................................
Signed:........................................................................................
Dealer's Stamp/CORGI Registration Number
Date of Service:...........................................................................
Next Service Due:.......................................................................
Signed:........................................................................................
Dealer's Stamp/CORGI Registration Number
8TH SERVICE
7TH SERVICE
Date of Service:...........................................................................
Next Due:........................................................................
Signed:........................................................................................
Dealer's Stamp/CORGI Registration Number
Date of Service:...........................................................................
Next Service Due:.......................................................................
Signed:........................................................................................
Dealer's Stamp/CORGI Registration Number
10TH SERVICE
9TH SERVICE
Date of Service:...........................................................................
Next Service Due:.......................................................................
Signed:........................................................................................
Dealer's Stamp/CORGI Registration Number
Date of Service:...........................................................................
Next Service Due:.......................................................................
Signed:........................................................................................
Dealer's Stamp/CORGI Registration Number
Download from Www.Somanuals.com. All Manuals Search And Download.
25
Gazco Limited, Osprey Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7jG
A member of the Stovax Group
Download from Www.Somanuals.com. All Manuals Search And Download.
|