LIMITEDWARRANTY
STORCASE TECHNOLOGY, Incorporated (StorCase) warrants that its products will be free
from defects in material and workmanship, subject to the conditions and limitations set forth
belowꢀ StorCase will, at its option, either repair or replace any part of its product that proves
defective by reason of improper workmanship or materialsꢀ Repair parts or replacement
products will be provided by StorCase on an exchange basis, and will be either new or
reconditioned to be functionally equivalent to newꢀ
This warranty does not cover any product damage that results from accident, abuse, misuse,
natural or personal disaster, external power surge or failure, or any unauthorized disassem-
bly, repair or modificationꢀ StorCase will not be responsible for any software, firmware or other
customer data stored within, or interfacing with a StorCase productꢀ
Duration of Warranty
Seven-Year Warranty: The following StorCase products are covered by this warranty for a
period of seven (7) years from the original date of purchase from StorCase or its authorized
®
®
®
resellers: all Data Express removable device enclosures and all Data Silo , Data Stacker and
®
InfoStation external expansion chassis, except for those components integrated into or
purchased separately for use with these products which are identified and covered by the three-
year or hard drive warranties described belowꢀ All StorCase interface cables and other
accessories specifically intended for use with the StorCase products identified above are also
covered by this (7) year warrantyꢀ
Three-Year Warranty: The following components integrated into or purchased separately for
use with StorCase Data Express, Data Silo, Data Stacker and/or InfoStation products are subject
to warranty for a period of three (3) years from the original date of purchase from StorCase or
its authorized resellers: all RAID controllers, power supplies, fans and blowersꢀ
Two-Year Warranty: The following StorCase products are covered by this warranty for a
period of two (2) years from the original date of purchase from StorCase or its authorized
®
resellers: all Rhino JR fixed external expansion chassis (model types FJR) and all RhinoJR
removable device enclosures (model types RJR)ꢀ
One-Year Warranty: All StorCase products identified as Reconditioned or Special Inventory
are covered by this warranty for a period of one (1) year from the original date of purchase from
StorCase or its authorized resellersꢀ Reconditioned products may only be exchanged for
reconditioned productsꢀ
Hard Disk Drive Warranty: All hard disk drives purchased from StorCase or through its
authorized resellers, whether purchased separately or integrated into StorCase products, are
subject to the warranty terms and conditions provided by the drive manufacturerꢀ
Third Party Software Warranty: All third party software purchased from StorCase for use
with and/or as part of StorCase products is subject to the warranty terms and conditions
provided by the software manufacturerꢀ
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
iii
Warranty Claim Requirements
To obtain warranty service, the defective product must be returned to your local authorized
StorCase dealer or distributor, or, with prior StorCase approval, to the StorCase factory
service centerꢀ
For defective products returned directly to StorCase, a Return Material Authorization (RMA)
number must be obtained by calling StorCase Customer Service at (714) 445-3455ꢀ The RMA
number must be prominently displayed on the outside of the return packageꢀ Shipments must
be freight-prepaid and insured, and must include the product serial number, a detailed
description of the problem experienced, and proof of the original retail purchase dateꢀ Products
must be properly packaged to prevent damage in transitꢀ Damage resulting from improper
packaging will not be covered by this warrantyꢀ The StorCase factory service center is located
at 17650 Newhope Street, Receiving Dock, Gate #4, Fountain Valley, CA 92780, UꢀSꢀAꢀ
Free Technical Support
StorCase provides free technical supportꢀ If you experience any difficulty during the
installation or subsequent use of a StorCase product, please contact StorCases Technical
Support Department prior to servicing your systemꢀ This warranty covers only repair or
replacement of defective StorCase products, as described aboveꢀ StorCase is not liable for,
and does not cover under warranty, any costs associated with servicing and/or installation
of StorCase productsꢀ
StorCase Technical Support can be reached in the UꢀSꢀ at (714) 438-1858 or toll-free at (888)
435-5460 (UꢀSꢀ and Canada only)ꢀ StorCase European Technical Support can be reached in
the UꢀKꢀ at +44 (0) 1932 738900ꢀ
Disclaimers
The foregoing is the complete warranty for the products identified above and
supersedes all other warranties and representations, whether oral or written'
StorCase expressly disclaims all warranties for the identified products, which are
not stated herein, including, to the extent permitted by applicable law, any implied
warranty of merchantability or fitness for a particular purpose' In no event will
StorCase be liable to the purchaser, or to any user of a StorCase product, for any
damages, expenses, lost revenues, lost savings, lost profits, or any other
incidental or consequential damages arising from the purchase, use or inability
to use a StorCase product, even if StorCase has been advised of the possibility
of such damages'
Copyright © 2005 StorCase Technologyꢀ All rights reservedꢀ All registered
trademarks are the property of StorCase Technologyꢀ All other logos and trademarks
are properties of their respective companiesꢀ
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
iv
Declaration of Conformity
StorCase Technology, Incꢀ
Company Name:
17600 Newhope Street
Fountain Valley, CA 92708
Corporate Office Address:
Manufacturing Address:
17600 Newhope Street
Fountain Valley, CA 92708
Data Express DE100
DE100i-XXXX/XXX
Product Name:
Model Number:
Conforms to the following standards:
ITEEmission
- EN 50081-1
EMC Directives:
(89/336/EEC)
- EN 61000-3-2 Harmonic Current
- EN 61000-3-3 Voltage Fluctuations and Flicker
- EN 50082-1
- EN 61000-4-2
- EN 61000-4-3
- EN 61000-4-4
- EN 61000-4-5
- EN 61000-4-6
- En 61000-4-8
- EN 61000-4-11
EN 60950
Low Voltage Directive:
(73/23/EEC)
CAN/CSA-C22ꢀ2 Noꢀ 950-95
UL 1950
Safety Standards:
CSA (NRTL/C)
EN 60950: 2000
TUV
FCC Part 15, Class B
EMI Standards:
EMC Standards:
Year of Manufacture:
AS/NZS 3548 Information Technology Equipment
2000
Signature:___________________
Full name: Dieter Paul
Position: President
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
v
Table of Contents
INTRODUCTION ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 1
Packaging Information ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 1
Serial Numbersꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 1
Package Contentsꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 2
General Description ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 3
Receiving Frame Front Panel ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 4
Receiving Frame Rear Panelꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 5
INSTALLATION ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 7
Installing the Drive into the Carrierꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 7
Drive Activity Indicator Connector (J5) ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 7
Installation ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 8
Installing the Receiving Frame ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 9
Selecting the Unit ID Number ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 10
Unit ID Select Switch Settings ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 12
I/O Connector J2 ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 13
APPENDICES ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 14
Appendix A - Specifications/Dimensions ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 15
Appendix B - Attaching the ON/OFF Key ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 17
Appendix C - Optional Accessoriesꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 18
Carrying Case ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 18
Drive Cover ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 19
Drive Plugꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 19
Solenoid Drive Lockꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 20
Reader's Commentsꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 21
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
vi
List of Figures
Figure 1:
Figure 2:
Figure 3:
Figure 4:
Figure 5:
Figure 6:
Figure 7:
Figure 8:
Figure 9:
Figure 10:
Package Contents ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 2
DE100i-A100 Receiving Frame and Carrier ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 3
Receiving Frame Front Panel ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 4
Receiving Frame Unit ID Number and Activity Display ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 5
Receiving Frame Rear Panel ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 6
Drive Carrier Circuit Boardꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 7
Drive Installation Assemblyꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 8
Master/Slave Configuration Jumper J5 ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 9
Receiving Frame Mounting Holes ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 10
Unit ID Select Switch Location ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 11
Figure A-1: DE100i-A100 Physical Dimensionsꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 16
Figure B-1: Attaching the ON/OFF Key ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 17
Figure C-1: Carrying Case ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 18
Figure C-2: Full Drive Cover ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 19
Figure C-3: Drive Plug ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 19
Figure C-4: Solenoid Mechanism ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 20
List of Tables
Table 1:
Table 2:
Unit ID Select Switch Settings ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 12
AT/IDE Interface Signals ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ 13
NOTICE:
This User's Guide is subject to periodic updates without noticeꢀ While reason-
able efforts have been made to ensure accuracy of this document, Stor-
Case Technology, Incꢀ assumes no liability resulting from errors or omissions
in this publication, or from the use of the information contained hereinꢀ
your StorCase representative for the latest revision of this documentꢀ
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
1
INTRODUCTION
Packaging Information
The StorCase Technology Data Express® system is shipped in a container designed to provide
protection and prevent damage during shipmentꢀ The Data Express unit was carefully
inspected before and during the packing procedure at the factoryꢀ Bent or broken connectors,
or evidence of other damage to the Data Express should be reported to the shipper immediatelyꢀ
Refer to Figure 1 for the package contentsꢀ
If the wrong Data Express model has been received, please call your reseller or StorCase at
(800) 435-0642 to arrange for a Return Material Authorization (RMA)ꢀ StorCase cannot ac-
cept returns which do not display an RMA number on the outside of the packageꢀ Return the
unit with all the original packing materialsꢀ
Before removing any component from its packaging, discharge any static electricity by
touching a properly grounded metal objectꢀ
Serial Numbers
Both the Data Express receiving frame and carrier are labeled with serial numbersꢀ These
numbers must be reported to the StorCase Customer Service Representative in order to
receive a Return Material Authorization (RMA) for warranty claimsꢀ Locate the serial number
labels and record the numbers in the spaces provided belowꢀ
Receiving Frame:
Drive Carrier:
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Introduction
Package Contents
The DE100i-A100 package contents include the following itemsꢀ If any items are missing
or damaged, contact your StorCase dealer for a replacementꢀ
Dat
a
Express
C
a
C
b
le
o
(P ve
ro
r
v
id
e
d
D
)
is
(N
k
o
D
ri
t
In
v
e
c
lu
d
e
P
a
d
)
o
w
e
I/
c
r
O
C
C
a
b
b
le
ID
le
S
e
le
t
D
C
ab
ri
ve
l
e
C
a
rr
ie
r
D
ri
ve
H
a
P
rd
M
o
h
w
3
ill
F
a
u
n
/1
ip
re
6
s
ti
n
#
(4
g
la
6
e
t
-3
a
H
2
)
D
x
C
a
S
b
le
c
#
re
2
C
01
6
w
51
Fl
-3
s
ov
p
a
(2
e
r
t
H
x
D
3
l
c
/
1
s
6
)
0430e
6ꢀ InsertSheet
7ꢀ #6-32PhillipsMachineHdꢀ
MountingScrews
8ꢀ #6-32PhillipsFꢀHꢀMounting
Screws
1ꢀ CableCover
2ꢀ AlignmentTool
3ꢀ DriveLockKeys
4ꢀ ReceivingFrame
5ꢀ Drive Carrier
Figure 1: Package Contents
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
3
General Description
NOTE:
For Ultra ATA133 (133MByte/sec) operation, an Ultra ATA/133 controller and hard
drive(s), and appropriate 40-pin, 80-conductor cable are requiredꢀ
The StorCase Technology Data Express® DE100i-A100 is a removable drive carrier and
receiving frame designed to provide durable and reliable mounting for 3ꢀ5 Ultra ATA133 drives
within 5ꢀ25" half-height peripheral slots (Figure 2)ꢀ It is downward-compatible with earlier
technology IDE drivesꢀ
The DE100i-A100 allows a drive to be removed and transported to another DE100i-A100-
equipped computer or expansion chassis, and also provides the ability to secure sensitive data
by removing and storing the drive safely for future useꢀ
Figure 2: DE100i-A100 Receiving Frame and Carrier
This User's Guide describes the steps required to install the StorCase Data Express
DE100i-A100 removable enclosure inside a computer peripheral bayꢀ This guide supplements
documentation provided with the host computer system, operating system, and the drive to
be installed within the Data Express carrierꢀ
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Introduction
Receiving Frame Front Panel
(Figure 3)
Key Lock/Drive Power Switch performs three (3) functionsꢀ The key lock
assures proper seating of the drive carrier within the receiving frame, turns power
to the drive carrier on and off, and prevents unauthorized removal or installation of
the carrierꢀ For the computer to access data on the DE100i-A100 drive, the key must
be turned counterclockwise to the locked positionꢀ
Unit ID Number Display (Figure 4) shows the physical address of the DE100i-A100
drive carrier when the carrier is Installed and Locked in the receiving frame or
Removed from the receiving frameꢀ If the drive carrier is Installed but Not Locked,
a "u" will be displayedꢀ The unit ID number is selected by means of the unit ID select
switch located inside the receiving frame using a special alignment tool supplied with
the DE100i-A100ꢀ This procedure is explained later during the installation processꢀ
Activity Indicator is a small dot next to the Unit ID Number which flashes when the
host computer is accessing data on the DE100i-A100 carrierꢀ Refer to Figure 6 on
page 7 and section "Drive Activity Indicator Connector (J5)" on page 8 for further
informationꢀ
Device Spin Down/Up Timer may be disabled by removing Jumper J6 P1-P2
(Figure 5)ꢀ This feature allows the receiving frame unit number display to provide
a visual indication of drive spin down/up activityꢀ
High Insertion
Count Mating
Connector
Carrier Guide
All Steel
Receiving
Frame
Device Spin
Down/Up
Timer Switch
Unit ID Number
Indicator
Receiving Frame
Front
Activity Indicator
2.
Key Lock/Drive
Power Switch
0231A
Figure 3: Receiving Frame Front Panel
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
5
Figure 4: Receiving Frame Unit ID Number and Activity Display
Receiving Frame Rear Panel
(Figure 5)
DC Power Connector (J3): The DE100i-A100 uses a standard 4-pin DC Power
Connector to accept DC powerꢀ
I/O Connector (J2): The input/output connector provides a standard interface for
all IDE signalsꢀ See Table 3 on page 13 for J2 pin assignmentsꢀ
Master/Slave Selection Jumper (J5): Master Drive configuration (default)ꢀ
Forces master drive configuration on receiving frameꢀ Change jumper to set slave
drive configurationꢀ Refer to Table 1 on page 12 for further informationꢀ
Device Spin Down/Up Timer Jumper (J6): Jumper installed (Factory Default)
enables device spin down/up visual indicatorꢀ Receiving frame unit ID number
display (Figure 4) will flash to indicate device spin down/upꢀ
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Introduction
Figure 5: Receiving Frame Rear Panel
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
7
INSTALLATION
Installing the Drive into the Carrier
NOTE:
A #2 Phillips screwdriver will be required during this procedureꢀ
While performing the steps in this section, work on a soft surface to prevent excessive shock
to the drive being installedꢀ Also refer to the manufacturer's documentation provided with the
driveꢀ
1ꢀ Remove the drive from its protective packagingꢀ
2ꢀ Plastic Drive Bezel: If the drive came equipped with a plastic front bezel, it must
be removed before installing the drive into the drive carrierꢀ
3ꢀ Master/Slave Drive Selection: In most cases, the drive will be factory-configured
as a Master Ultra ATA133 drive using a jumper plug on the drive itselfꢀ No con-
figuration changes are requiredꢀ For multiple drive configurations, it is necessary
to set the first Ultra ATA133 drive as Master and the second Ultra ATA133 drive to
Slaveꢀ This can be done by changing the jumper on the Ultra ATA133 drive itself
(refer to your drive manufacturer documentation for further information)ꢀ
Figure 6: Drive Carrier Circuit Board
Drive Activity Indicator Connector J5 (Drive Carrier Circuit Board)
Jumper removed (factory default) disables drive activity indicator (Figure 4)ꢀ
Jumper installed enables drive activity indicatorꢀ
NOTE:
If two (2) drives are installed (with J5 enabled on both drives), both drive activity
indicators will flash simultaneously, even if only one drive is being accessedꢀ
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Installation
Installation
1ꢀ Attach the I/O cable on the drive carrier circuit board to the driveꢀ Refer to Figure
7 for an illustration of the installation processꢀ
2ꢀ Attach the power cable on the drive carrier circuit board to the driveꢀ Carefully insert
the drive into the drive carrier at an angle, cable-end firstꢀ Make sure none of
the cables are pinched' Lower the front of the drive carefully into placeꢀ Fasten
the drive into the carrier with the four (4) screws provided as shown in Figure 7ꢀ
3ꢀ Install the provided cable coverꢀ
Figure 7: Drive Installation Assembly
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
9
Installing the Receiving Frame
The drive should be installed into the carrier before installing the receiving frame into the
mounting bay of a computer or expansion chassisꢀ
NOTE:
Use a #2 Phillips screwdriver for this procedureꢀ
1ꢀ Turn OFF power to the computerꢀ
2ꢀ Open the computer system according to the manufacturers instructionsꢀ If neces-
sary, temporarily remove any expansion boards that may make installation difficultꢀ
3ꢀ Select the Master/Slave configuration on the rear of the receiving frame by placing
a jumper on the appropriate (J5) pins (Figure 8)ꢀ Remove the jumper if you wish
to use the Unit ID Select switch on the receiving frame to configure the Master/Slave
drive selectionꢀ Refer to Table 1 for further informationꢀ
NOTE:
The unit ID select switch configures the unit ID display onlyꢀ The
master/slave setting on must still be set on the drive itself (refer to the
drive manufacturer's documentation for further information)ꢀ
Master Drive Select
(Factory Default)
Slave Drive Select
J5
0423A
Figure 8: Master/Slave Configuration Jumper J5
4ꢀ With the drive carrier locked in place inside the receiving frame, install the
DE100i-A100 into the 5ꢀ25 drive opening in the computer or expansion chassisꢀ Use
the appropriate guides to position the Data Express, and fasten it into place with the
four (4) #6-32 Phillips screws providedꢀ Figure 9 illustrates the location of the
mounting holesꢀ Mounting holes are provided on each side and the bottom of the
receiving frame to accommodate a variety of mounting configurationsꢀ Use the
mounting holes which best suit the computer or expansion chassis configurationꢀ
Note that bottom mounting holes require self-tapping screws (not provided)ꢀ
5ꢀ Adjust the front of the receiving frame so the carrier slides freely in and out on the
receiving frame guidesꢀ The position of adjoining peripheral units may require ad-
justmentꢀ
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Installation
Front of Unit
Mounting
Holes (Left)
Mounting
Holes (Right)
Mounting
Holes (Bottom)
0086
Figure 9: Receiving Frame Mounting Holes
6ꢀ ConnecttheI/Ocablefromthehostadaptertothereceivingframeꢀ ThePin1 indicator
on the cable must be properly alignedꢀ Refer to Figure 5 for the correct Pin 1 locationꢀ
7ꢀ Connect the power cable from the DC power supply in the computer or expansion
chassis to the power connector on the DE100i-A100 receiving frameꢀ Refer to
Figure 5 for the DE100i-A100 receiving frame power connector locationꢀ
8ꢀ Replace any expansion boards that may have been removed earlierꢀ Replace the
system cover according to the manufacturers instructionsꢀ
9ꢀ Reconnect any system or peripheral cables removed earlierꢀ
10ꢀ Turn ON power to the computerꢀ If the installation has been successful, and all the
cables have been properly attached, the system should boot normallyꢀ Although the
computer may not recognize the DE100i-A100 yet, the front panel display on the
DE100i-A100 receiving frame should illuminateꢀ
11ꢀ The new drive may need to be formatted or initialized prior to use with the operating
system and applications softwareꢀ Refer to the drive and/or computer manufacturer's
documentation for formatting informationꢀ
Selecting the Unit ID Number
1ꢀ Verify that power is turned ON to the DE100i-A100 receiving frame by turning on
your computerꢀ A number will appear in the unit ID display window if the carrier is
locked in placeꢀ
2ꢀ Unlock the DE100i-A100 drive carrier and remove it from the receiving frameꢀ A "u"
will be displayed initially when the unit is unlocked but will return to a number when
the carrier is removed from the receiving frameꢀ
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
11
WARNING:
Unlocking the carrier unit switches DC power off to the driveꢀ Since
disk drives require a short amount of time to spin down, allow about
15 seconds before pulling the carrier unit out of the receiving frame
to avoid possible damage to the driveꢀ
3ꢀ Use the alignment tool supplied with the DE100i-A100 to select the ID number of the
disk driveꢀ Refer to Figure 10 for the location of the ID Select Switch inside the
receiving frameꢀ Table 2 lists the valid unit ID numbers available for the driveꢀ
4ꢀ After you have selected an appropriate unit number, replace the DE100i-A100
carrier in the receiving frame, and LOCK IT IN PLACEꢀ
NOTE:
The lock on the DE100i-A100 receiving frame functions as a lock and
a DC power switch for the carrier unitꢀ The lock must be engaged
in order to supply power to the carrier and installed driveꢀ
5ꢀ Reboot the computerꢀ The new disk is now ready for use, although it may have to
be formatted or initialized prior to use with your operating system and applications
softwareꢀ
Unit ID
Number
Display
Lock
Unit ID Select
and DC
Rotating Switch
Power
Switch
Front of Unit
Drive Carrier
Guide
Receiving
Frame
0087
Drive Carrier
(removed)
Figure 10: Unit ID Select Switch Location
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Installation
Unit ID Select Switch Settings
The following table lists the Unit ID Select Switch settings and the valid AT/IDE unit numbersꢀ
Please note that all invalid switch settings have X's through them and result in a blank display
in the receiving frame display windowꢀ
Table 1: Unit ID Select Switch Settings
Unit ID Select
Position
0
1
2
3
4
5
6
7
8
9
Ultra ATA/100
Drive
1
0
2
1
1
2
2
3
Unit ID Number
Display
Blank
Blank Blank
Blank Blank Blank
(with both jumpers
removed from J5)
Drive
Selection
Master Slave
Master Slave
824
NOTE:
The unit ID number display is for ID display purposes onlyꢀ The master/slave
setting must still be set on the drive itself (refer to the drive manufacturer's
documentation for further information)ꢀ
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation
13
I/O Connector J2
The I/O connector (J2) pin assignments are as follows:
Table 2: AT/IDE Interface Signals
Pin
01
03
05
07
09
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
Signal
Host Reset-
Host Data 7
Host Data 6
Host Data 5
Host Data 4
Host Data 3
Host Data 2
Host Data 1
Host Data 0
Ground
DMARQ
DIOW-
DIOR-
Reserved
Reserved
IRQ14
Host ADDR 1
Host ADDR 0
Host CS0-
DASP-
I/O
O
Pin
02
Signal
I/O
Ground
Host Data 8
Host Data 9
Host Data 10
Host Data 11
Host Data 12
Host Data 13
Host Data 14
Host Data 15
Key
Ground
Ground
Ground
Reserved
Ground
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
04
06
08
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
I/O
I/O
I/O
I/O
I/O
I/O
I/O
I/O
NoPin
O
O
O
I
O
O
O
Notes
Host IO16-(AT)
PDIAG- (16)
Host ADDR 2
Host CS1-
Ground
I
Notes
O
O
- Indicates an active-low signalꢀ
Signal direction is with respect to the hostꢀ
"I" indicates To the host
"O" indicates From the host
The /PDIAG and /DASP signals are used for communication between master, slave, and the
hostꢀ
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
14
APPENDICES
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A - Specifications/Dimensions
15
Appendix A - Specifications/Dimensions
Environmental Specifications
Operating
Storage
Ambient Temperature
RelativeHumidity(1)
Altitude
-5° C to 50° C
10% to 80%
-45° C to 75° C
10% to 90%
-1000 to 50,000 ft
-304m to 15240m
10g60g
-1000 to 50,000 ft
-304m to 15240m
Shock (2)
(1)Non-condensing with maximum gradient of 10% per hourꢀ
(2)11 msec pulse width 1/2 sine waveꢀ
Physical
Specifications
Height
Carrier
Receiving Frame
1ꢀ70" (43ꢀ2mm)
1ꢀ68" (42ꢀ7mm)
4ꢀ67" (118ꢀ6mm)
7ꢀ38" (187ꢀ5mm)
Width
5ꢀ75" (146ꢀ1mm)
8ꢀ18" (207ꢀ8mm)
Depth
Weight
1ꢀ1lb (0ꢀ50kg)
1ꢀ25lb (0ꢀ57kg)(1)
(1)With carrier removedꢀ
Chassis Reliability/Maintainability
MTBF
500,000 Hours
5 Minutes
MTTR
Preventive
Maintenance
None
Electrical Specifications
Input
+5V
65mA
+12V
400mA
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
16
Appendix A - Specifications/Dimensions
Figure A-1: DE100i-A100 Physical Dimensions
(Dimensions are for reference only)
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix B - Attaching the ON/OFF Key
17
Appendix B - Attaching the ON/OFF Key
The following information describes the necessary steps to attach the ON/OFF key to the key
lock mechanism so that it is non-removable, preventing accidental key lossꢀ The procedure
can be reversed at a later date to revert back to a removable keyꢀ
1ꢀ Make certain power is OFF to the receiving frameꢀ
Locate the rectangular shaped key lock mecha-
nism access hole on the inside of the receiving
frameꢀ Note that the pawl is in an upright positionꢀ
Insert the key into the lockꢀ
2ꢀ Rotate the key 90 degrees counterclockwise so
that the pawl is visible in the access hole as
shown in the figure at leftꢀ
3ꢀ Using the provided alignment tool, unscrew and
remove the pawl from the access holeꢀ
4ꢀ Rotate the key 180 degrees clockwise (or coun-
terclockwise)ꢀ
5ꢀ Reinstall the pawl into the access hole with the
alignment toolꢀ
The key lock has now been reconfiguredꢀ
Figure B-1: Attaching the ON/OFF Key
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
18
Appendix C - Optional Accessories
Appendix C - Optional Accessories
Carrying Case
320FW_13
Figure C-1: Carrying Case
The optional molded plastic carrying case (P/N S20E104), is designed to transport the
DE100i-A100 carrier from one site to another in a safe, impact and moisture resistant
environmentꢀ Its compact dimensions, 7 long x 9 wide x 3ꢀ5 high, make it easy to carry and
tostoreꢀ ThefoamliningiscontouredtofitasingleDE100i-A100carrierꢀ ContactyourStorCase
dealer for further details and ordering informationꢀ
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix C - Optional Accessories
19
Drive Cover
1
2
Slip Drive Cover
Lip into Top Rear
of Carrier. The
Sides of the Cover
Will Fit Between
the Drive and the
Carrier. Mounting
Holes Must be
Towards Rear of
Carrier.
1
3
Slide Drive Cover
Forward Making Certain
Front Cover Lip is Inside
Carrier. Fasten Screws.
2
Drive
Cover
3
Swing Drive Cover
Down, Covering
the Drive. Make
Certain You Do
Not Damage
Connector Pins or
Cables.
Mounting
Holes
Disk
Carrier
0067
Full Drive Cover (optional)
Figure C-2: Full Drive Cover
The full drive cover (P/N DX100-COV), is an attractive metal cover which can provide additional
protection to the drive, preventing foreign material from coming in contact with the drive and
cablesꢀ The full drive cover is similar to the cable cover provided with the DE100i-A100, except
the full drive cover protects the drive as well as the cablesꢀ It is easily installed with two (2)
#6-32 Phillips Flat Hdꢀ screws as shown in the illustration aboveꢀ
Drive Plug
0429
Figure C-3: Drive Plug
The drive plug (P/N DX100-PLUG), is designed to fill system or external enclosure bays that
are occupied by receiving frames that have no carrier units installedꢀ The purpose of the plug
is to provide an attractive and functional method of directing proper air flow to the other installed
devices in the system or external enclosureꢀ
DE100i-A100 User's Guide - Revꢀ C02
StorCase Technology, Incꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
20
Appendix C - Optional Accessories
Solenoid Drive Lock
The factory installed solenoid option prevents premature removal of the carrier and drive unit
until the target drive has fully spun downꢀ For disk drives, this period of time can range from
15-40 seconds, depending on the type of drive being used (eꢀgꢀ Barracuda drives require up
to 50 seconds)ꢀ Refer to the drive manufacturer's documentation for specific drive informationꢀ
The solenoid lock is controlled by a timing switch located on the side of the receiving frameꢀ
The solenoid option provides an extra step in drive protection by preventing the removal and
movement of the drive until the drive motor has fully stoppedꢀ
Figure C-4: Solenoid Mechanism
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
21
Reader's Comments
Please take a few moments when your computer system is up and running to send us your
ideas and suggestions for improving our products and documentationꢀ Did the installation go
smoothly for you? Are there any changes you would like us to make, either with the hardware
itself, or with the installation instructions? Everyone at StorCase Technology is working
toward the goal of providing you with the highest quality, most cost effective, products
available on the market, and we need your comments to guide our effortsꢀ We look forward
to hearing from you soon!
Date:
Your Name:
Address:
Telephone: (
)
To mail this page, carefully remove it from the manual, fold it, staple or tape it shut, and drop
it in the mailꢀ To FAX this page, carefully remove it from the manual (or make a photocopy) and
FAX it to us at (714) 438-1847ꢀ Thank you for taking the time to help us make our products
better!
StorCase Technology, Incꢀ
DE100i-A100 User's Guide - Revꢀ C02
Download from Www.Somanuals.com. All Manuals Search And Download.
FOLD ALONG THIS LINE AND STAPLE SHUT
NO POSTAGE
NECESSARY
IF MAILED
IN THE
UNITED STATES
BUSINESS REPLY MAIL
FIRST CLASS MAIL PERMIT NO. 10686 SANTA ANA, CA
POSTAGE WILL BE PAID BY ADDRESSEE
17600 NEWHOPE STREET
FOUNTAIN VALLEY CA 92708-9885
Download from Www.Somanuals.com. All Manuals Search And Download.
|