IMPORTANT FOR FUTURE REFERENCE
Please complete this information and retain
this manual for the life of the equipment:
Model #: __________________________
Serial #: __________________________
Date Purchased: ___________________
Owner’s Manual
StratoSteam
Countertop Steamer
Models STRE-3EZ and STRE-5EZ
WARNING
Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death.
Read installation, operation, and maintenance instructions thoroughly before installing or servicing this equipment.
MANUAL 1185184
$18.00
STRATOSTEAM COUNTERTOP STEAMER
MANUAL SECTION STRATOSTEAM
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
INTRODUCTION
INTRODUCTION
Congratulations! You have purchased one of the finest pieces of heavy-duty commercial cooking equipment on the
market.
You will find that your new equipment, like all Southbend equipment, has been designed and manufactured to meet
the toughest standards in the industry. Each piece of Southbend equipment is carefully engineered and designs are
verified through laboratory tests and field installations. With proper care and field maintenance, you will experience
years of reliable, trouble-free operation. For best results, read this manual carefully.
RETAIN THIS MANUAL FOR FUTURE REFERENCE.
This manual is for Southbend StratoSteam Countertop Steamer models STRE-3EZ and STRE-5EZ. The manual is
divided into six sections:
Introduction............................................3
Specifications.........................................4
Operation...............................................7
Cleaning & Maintenance........................11
Installation..............................................13
Service...................................................18
Each steamer has two serial plates located on the exterior of the steamer (see Figure 1 below).
Read these instructions carefully before attempting installation. Installation and initial startup should be performed by
a qualified installer. Unless the installation instructions for this product are followed by a qualified service technician (a
person experienced in and knowledgeable with the installation of commercial gas and/or electric cooking equipment)
then the terms and conditions on the Manufacturer’s Limited Warranty will be rendered void and no warranty of any
kind shall apply.
In the event you have questions concerning the installation, use, care, or service of the product, write to:
Southbend
1100 Old Honeycutt Road
Fuquay-Varina, North Carolina 27526 USA
Figure 1
Location of Serial Plates
OWNER’S MANUAL 1185184
PAGE 3 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
STRATOSTEAM COUNTERTOP STEAMER
SPECIFICATIONS
NOTICE
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association,
Inc., states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to
installation requirements for equipment. Therefore, installations should comply with all local codes.
The steamer, when installed, must be electrically grounded and comply with local codes, or in the absence of local
codes with the National Electrical Code ANSI/NFPA 70-latest edition.
Canadian installations must comply with CSA-Standard (C22.2 No. 109-M1981 General Requirements-Canadian
Electrical Code, Part II. 109-M1981) Commercial Cooking Appliances.
Southbend reserves the right to change specifications and product design without notice. Such revisions do not
entitle the buyer to corresponding changes, additions, or replacements for previously purchased equipment.
This product is intended for commercial use only, not for household use.
CLEARANCES
WARNING
MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION
Minimum clearance from combustible and non-combustible surfaces is 0" on the sides, bottom, and top; and 4" on
the rear. Adequate clearance must be provided in the aisle in front of the steamer to permit operation (including
pulling out of pans).
Steam may escape from the pressure relief valve at the top left rear corner of each steamer, and from the door
opening when the door is opened. Installation under a vented hood is recommended.
A steamer may be installed on combustible and non-combustible countertops.
DIMENSIONS
The dimensions of the steamer are shown in Figure 2 on the next page. The following table lists the interior
dimensions and the crate dimensions and weight.
Interior Dimensions
Pan Capacity*
Crate Dimensions
Crated
Weight
Model
Width
Depth
Height
1"
2.5"
4"
Width
Depth
Height
Volume
13-1/2"
(343)
24"
(610)
10-5/8"
(270)
52"
(1321)
43"
(1092)
40"
(1016)
51.8 cu. ft.
1.47 cu. m.
216 lbs.
98 kg.
STRE-3EZ
STRE-5EZ
6
3
2
3
13-1/2"
(343)
24"
(610)
15-5/8"
(397)
52"
(1321)
43"
(1092)
40"
(1016)
51.8 cu. ft.
1.47 cu. m.
238 lbs.
108 kg.
11
5
* “Pan Capacity” is the number of 1", 2.5", or 4" high standard pans (12" wide x 20" front-to-back) that the steamer will hold.
PAGE 4 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
OPERATION
Figure 2
Dimensions
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
PAGE 5 OF 44
OPERATION
STRATOSTEAM COUNTERTOP STEAMER
ELECTRICAL REQUIREMENTS
One fused electrical connection is required to the contactor of each steamer. All steamers are shipped per customer
order, three phase or single phase. (A kit is available for field conversion to three phase or single phase.) The fused
connection must be wired for the required voltage and maximum amperage as listed in the chart below:
Total Connected Amps
Voltage
Model STRE-3EZ
1 Phase 3 Phase
44 26
Model STRE-5EZ
1 Phase 3 Phase
53 31
208 V 60 Hz
220 V 50/60 Hz
240 V 60 Hz
41
38
24
22
51
46
29
27
WATER REQUIREMENTS
To meet warranty requirements, the water supply must be as follows:
Total Dissolved Solids (TDS)
60 PPM or less
2 grains (35 PPM) or less
7.0 to 7.5
Hardness
pH
Maximum Reservoir Capacity
3.0 gallons
Typical usage is 3.0 gallons in 4 hours.
In order to minimize service problems and to meet the warranty requirements, a water treatment system (softener) is
recommended when water quality does not meet the limits stated above.
DRAIN REQUIREMENTS
Water drains into a pan attached to the bottom of the steamer. Pan pulls out for periodic dumping.
PAGE 6 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
OPERATION
OPERATION
NOTICE: WATER SPECIFICATION
To meet warranty requirements, supply water must meet the following specification:
Total Dissolved Solids (TDS)............60 PPM or less
Hardness...........................................2 Grains (35 PPM) or less
pH Factor ..........................................7.0 to 7.5
STARTUP
Fill steamer with 3.0 gallons of water through upper trough as shown in Figure 3. Turn control lever to “ON” position
(see Figure 4). The steamer will fill automatically and be ready for cooking in about four minutes.
Figure 3
Location of Water Trough
OPERATION
CAUTION
HOT STEAM WILL ESCAPE WHEN DOOR IS BEING OPENED. TO PREVENT BURNS KEEP HANDS AND
FACE AWAY FROM STEAM.
When turned ON, the steamer operates continuously. To save water and electricity, turn the control lever to OFF
when the steamer is not in use.
Suggested cooking times for various foods are shown in the table in the following section.
Pan specifications are shown on page 4.
The door may be opened or closed at any time. The steamer temporarily shuts off while the door is open.
Timer can be used as a reminder to the operator. The timer does NOT turn the steamer on or off!
When low water indicator light turns ON, fill steamer with water.
Periodically check drain pan for water accumulation, empty drain pan if necessary.
OWNER’S MANUAL 1185184
PAGE 7 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
STRATOSTEAM COUNTERTOP STEAMER
SHUTDOWN
Turn lever to the “OFF” position. The water in the bottom of the cavity will automatically drain.
TROUBLESHOOTING BY OPERATOR
The following table lists the possible causes and solutions of problems that may occur during operation.
Problem
Possible Causes and Solutions
Steamer does not heat up at all.
– Electric power is shut off. Turn on power.
– Not enough water is in steamer. Add water.
– Lime build-up. De-lime steamer cavity (see page 11).
– If water is OK and there is little lime build-up, call repair service.
Steamer does heat up, but does not produce enough steam.
Steamer does not drain correctly.
– Door is open or ajar. Close steamer door completely.
– Lime build-up. De-lime steamer cavity (see page 11).
– Not enough water. Add water.
– Clogged drain on inside of steamer cavity. Check and clear.
– Clogged drain outside of steamer. Check and clear.
PAGE 8 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
OPERATION
Figure 4
Controls
COOKING TIPS
•
Schedule cooking of fresh vegetables so that they will be served soon after they are cooked. If it is necessary to
prepare them in advance, they can be plunged into cold water, drained thoroughly and held under refrigeration
until needed for service. Five pounds of cold cooked vegetables can be reheated in the steamer in 5 to 10
minutes, depending upon the variety.
OWNER’S MANUAL 1185184
PAGE 9 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
STRATOSTEAM COUNTERTOP STEAMER
•
•
To avoid green yolk (which is a deposit of iron sulfide) chill the eggs immediately after removing from the
steamer by plunging them into a cold water bath (preferably containing ice).
A quick and easy way to cook eggs for a salad mixture is to crack them directly into a solid steam table pan
which has been lightly coated with salad oil. Do not mix. Steam until they are hard cooked. Remove and chop as
you would for egg salad. The job of peeling is eliminated.
•
Chicken, sausage, and/or fish may be browned in an infra-red or radiant broiler after steaming by brushing with
melted margarine mixed with salad oil to give a golden brown color.
•
•
•
Save juices from steamed meat and poultry to make soups, sauces, or casserole dishes.
Chicken may be steamed in advance and then refrigerated. Bring food back to 180°F before serving.
Steaming brisket is a definite time saver. Boiling in water takes 40 to 50 minutes per pound. Using the steamer
can save 50% in cooking time.
•
•
Steamed cabbage retains its color and wedge identity. It will not break apart as it does when boiled.
When removing items prepared in a perforated pan, place a solid pan underneath the perforated pan with the
cooked food in order to prevent dripping on the floor.
•
•
•
The steamer is designed to accept standard 12" x 20" pans. Fractional size pans and dishes can be used as
well with a perforated shelf.
For stirring, the pan does not have to be removed from the steamer. Pull pan 1/3 way out of the cavity and the
entire surface is accessible.
The door may be opened at any time during operation to remove or add food. While the door is open, the
steamer will stop producing steam.
SUGGESTED COOKING TIMES
These cooking times are for general guidance only. Differences in food quality, size, shape, thickness, freshness, load
size, and desired degree of doneness must be taken into consideration and adjustments made in time, if necessary.
STRE-3EZ Cooking
Time (minutes)
STRE-5EZ Cooking
Time (minutes)
Product
Quantity
18
48
5
6
6
7
Eggs
4 lbs.
8 lbs.
18
18
18
18
Potatoes, Red
Rice
2 lbs.
3 lbs.
15
15
16
17
2.5 lbs.
8 lbs.
4.5
8
4
7
Shrimp, Frozen
Corn, Frozen
Peas, Frozen
2.5 lbs.
7.5 lbs.
3
5
2.5
4.5
5 lbs.
12 lbs.
5.5
10
4
8
2.5 lbs.
8 lbs.
15 lbs. (3 full pans)
25 lbs. (5 full pans)
4
6.5
14
-
3.25
5.5
-
Mixed Vegetables, Frozen
17
1 piece
8 pieces
7
7
7
7
Salmon Filets, Frozen, 4.5 oz.
Salmon Filets, Frozen, 6 oz.
8 pieces
18 pieces (3 full pans)
30 pieces (5 full pans)
12
17
-
10
-
15
1
3
5
65
65
-
60
-
60
Lasagna, 6 lb., Frozen
Cake, White, 5 lb. Mix
1 pan
30
25
PAGE 10 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
CLEANING & MAINTENANCE
CLEANING & MAINTENANCE
WARNING
Shut off the steamer before cleaning or performing maintenance.
Southbend appliances are sturdily constructed of the best materials and are designed to provide durable service when
treated with ordinary care. To expect the best performance, your equipment must be maintained in good condition and
cleaned daily. Naturally, the periods for this care and cleaning depend on the amount and degree of usage.
Following daily and periodic maintenance procedures will enhance long life for your equipment. Climatic conditions
(such as salt air) may require more thorough and frequent cleaning or the life of the equipment could be adversely
affected.
Keep exposed, cleanable areas clean at all times.
DAILY CLEANING AND MAINTENANCE
NOTICE
DO NOT USE high-chlorine or bleach solution for cleaning the door gasket.
DO NOT USE steel wool or other metallic pads in the steamer.
1. Turn control lever to “OFF” and allow time for the steamer to drain and cool.
2. Remove and clean pans.
3. Remove and clean pan supports and cavity bottom cover. Wash separately in a sink with a mild detergent and
warm water. Dry thoroughly with a clean cloth. Non-metallic scouring pads may be used to remove cooked-on
deposits.
4. Clean all interior surfaces with mild detergent, warm water, and a non-metallic pad. If discoloration of surfaces
starts due to buildup of seasonings or food products, remove them using a non-metallic scouring pad. RINSE
THOROUGHLY WITH CLEAN WATER. Dry thoroughly with a clean cloth.
5. Ensure drain opening inside of cavity is clear.
6. Clean drain opening.
7. Place cleaned cavity bottom cover, pan supports, and pans back into their correct positions.
8. Leave the door open at night after cleaning to allow complete drying and to prolong the life of the door gasket.
PERIODIC DE-LIMING (AS NEEDED)
If lime or mineral deposits start to buildup on the cavity interior, they should be removed with a non-caustic de-liming
solution such as Lime-A-Way®. Follow the manufacturer’s instructions for use of the de-liming solution.
STAINLESS-STEEL SURFACES
To remove normal dirt, grease and product residue from stainless steel surfaces that operate at LOW temperature,
use ordinary soap and water (with or without detergent) applied with a sponge or cloth. Dry thoroughly with a clean
cloth.
To remove BAKED-ON grease and food splatter, or condensed vapors; apply cleanser to a damp cloth or sponge and
rub cleanser on the metal in the direction of the polishing lines on the metal. Rubbing cleanser, as gently as possible,
in the direction of the polished lines will not mar the finish of the stainless steel. NEVER RUB WITH A CIRCULAR
MOTION. Soil and burnt deposits which do not respond to the above procedure can usually be removed by rubbing
the surface with SCOTCH-BRITE scouring pads or STAINLESS scouring pads. DO NOT USE ORDINARY STEEL
WOOL as any particles left on the surface will rust and further spoil the appearance of the finish. NEVER USE A
WIRE BRUSH, STEEL SCOURING PADS (EXCEPT STAINLESS), SCRAPER, FILE OR OTHER STEEL TOOLS.
OWNER’S MANUAL 1185184
PAGE 11 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING & MAINTENANCE
STRATOSTEAM COUNTERTOP STEAMER
Surfaces which are marred collect dirt more rapidly and become more difficult to clean. Marring also increases the
possibility of corrosive attack. Refinishing may then be required.
“Heat tint” is darkened areas that sometimes appear on stainless steel surfaces where the area has been subjected to
excessive heat. These darkened areas are caused by thickening of the protective surface of the stainless steel and
are not harmful. Heat tint can normally be removed by the foregoing, but tint which does not respond to this procedure
calls for a vigorous scouring in the direction of the polish lines using SCOTCH-BRITE scouring pads or a STAINLESS
scouring pad in combination with a powered cleanser.
PAGE 12 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
INSTALLATION
INSTALLATION
CAUTION
Do not locate steamer adjacent to any high heat or grease producing piece of equipment, such as a range top,
griddle, fryer, etc., that could allow radiant heat to raise the exterior temperature of the steamer body above
130°F (54°C). DO NOT MOUNT ABOVE OTHER COOKING EQUIPMENT.
NOTICE
These installation procedures must be followed by qualified personnel or warranty will be void.
Local codes regarding installation vary greatly from one area to another. The National Fire Protection Association,
Inc., states in its NFPA 96 latest edition that local codes are the “authority having jurisdiction” when it comes to
installation requirements for equipment. Therefore, installations should comply with all local codes.
The steamer, when installed, must be electrically grounded and comply with local codes, or in the absence of local
codes with the National Electrical Code ANSI/NFPA 70-latest edition.
Canadian installations must comply with CSA-Standard (C22.2 No. 109-M1981 General Requirements-Canadian
Electrical Code, Part II. 109-M1981) Commercial Cooking Appliances.
NOTICE
EXHAUST FANS AND CANOPIES: It is recommended that the steamer be installed under a ventilation hood.
Consult local codes for proper installation of hoods. Proper ventilation is the owner’s responsibility. Any problem
due to improper ventilation will not be covered by warranty.
LEVELING: Steamer must be level for proper operation. Improper leveling may void the warranty.
STEP 1: UNPACKING
IMMEDIATELY INSPECT FOR SHIPPING DAMAGE
All containers should be examined for damage before and during unloading. The freight carrier has assumed
responsibility for its safe transit and delivery. If damaged equipment is received, either apparent or concealed, a
claim must be made with the delivering carrier.
Apparent damage or loss must be noted on the freight bill at the time of delivery. The freight bill must then be
signed by the carrier representative (Driver). If the bill is not signed, the carrier may refuse the claim. The carrier
can supply the necessary forms.
A request for inspection must be made to the carrier within 15 days if there is concealed damage or loss that is not
apparent until after the equipment is uncrated. The carrier should arrange an inspection. Be certain to hold all
contents plus all packing material.
Do the following:
1. Cut the banding straps and remove the corrugated cardboard surrounding the steamer. If legs were shipped in
the same container, set them aside for installation in later steps of this procedure. Do not remove any tags or
labels attached to the steamer until the steamer is installed and working properly.
2. If the steamer was shipped on a wooden skid, cut the banding strap holding the steamer to the wooden skid,
unbolt the shipping hold-down brackets from the skid, then remove the brackets from the steamer.
3. If the steamer is to be installed on legs, go to Step 2a.
If the steamer is to be mounted on the optional cabinet base, go to Step 2b.
If two steamers are to be stacked, go to Step 2c.
OWNER’S MANUAL 1185184
PAGE 13 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
STRATOSTEAM COUNTERTOP STEAMER
STEP 2A: ATTACH LEGS AND BRACKETS
A set of four legs is packed with steamers ordered with legs.
A threaded hole is located at each corner. Each leg has a corresponding mating thread. The legs can be adjusted to
overcome a slightly uneven surface.
1. Raise the steamer sufficiently to allow the legs to be attached. For safety, “shore up” and support the steamer
with an adequate blocking arrangement strong enough to support the load.
2. Screw the legs into the holes (see Figure 5). Note that the front legs are different than the rear legs.
3. Lower the steamer gently onto a level surface. Never drop or allow the steamer to fall.
4. Make sure that the steamer is level (both side-to-side and front-to-back). If necessary, adjust the height of each
leg by turning the foot-pad of the leg.
5. Go on to Installation Step 3.
Figure 5
Attach Legs and Brackets
STEP 2B: MOUNTING ON CABINET BASE
If the steamer is to be mounted on the optional cabinet base, first attached the legs to the cabinet base (if not already
attached). Then place the steamer on top of the cabinet base and line up the threaded holes on the bottom of the
steamer with the holes in the cabinet-base top. Secure the steamer to the base with four 3/8-16 bolts. Go on to
Installation Step 3.
STEP 2C: STACKING TWO STEAMERS
If two steamers are to be stacked, mount the lower steamer first on either legs (Step 2a) or the optional cabinet base
(Step 2b). Remove (if present) the four chrome-plated plugs from the holes in the top panel of the lower steamer.
Place the upper steamer on top of the lower steamer and line up the threaded holes on the bottom of the upper
steamer with the holes in the top of the lower steamer. Secure the upper steamer to the lower steamer with four 3/8-
16 bolts. The remaining steps of the installation must be performed for both steamers (they do not share any
connections internally).
PAGE 14 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
INSTALLATION
Figure 6
Location of Connections and Vents
STEP 3: WATER CONNECTION
NOTICE
To meet warranty requirements, the supply water must meet the following specifications:
Pressure
30 to 60 PSI (205 to 410 kPa)
60 PPM or less
Total Dissolved Solids (TDS)
Hardness
pH
2 grains (35 PPM) or less
7.0 to 7.5
STEP 4: ELECTRICAL CONNECTION
The electric connection is made to the contactor, which is located inside the service compartment on the right side of
the steamer. The right side panel must be removed to gain access to the contactor. A hole on the rear of each
steamer is provided for a 3/4" conduit fitting (solid or flex). An electric cable support bracket and clamp are located
inside of the service compartment, to the right and above the contactor (see Figure 7).
Be sure that the input voltage and number of phases matches the requirement stated on the serial plate. The steamer
is factory wired per customer order. A wiring diagram is attached to the inside of the right side panel of the steamer.
WARNING
A POSITIVE GROUND CONNECTION IS ESSENTIAL. DO NOT ALLOW ANY TAMPERING OR
ADJUSTMENT OF ANY CONTROL OR WIRING. THE STEAMER IS FACTORY SET. ADJUSTING ANY
INTERNAL COMPONENT CAN VOID THE WARRANTY.
THIS STEAMER REQUIRES A KIT TO BE FIELD CONVERTED FROM THREE-PHASE TO SINGLE-PHASE
OR VICE-VERSA. CONSULT FACTORY FOR PHASE CHANGES.
OWNER’S MANUAL 1185184
PAGE 15 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
INSTALLATION
STRATOSTEAM COUNTERTOP STEAMER
For 3-wire 3-phase installations, connect wires L1, L2, and L3 to the three terminals on the upper end of the contactor.
For 2-wire 1-phase installations, connect wires L1 and L2 to the two outer terminals on the upper end of the contactor.
Make the electrical ground connection to the ground lug located at the top right-hand corner of the contactor bracket.
Figure 7
Electrical Connection
PAGE 16 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
INSTALLATION
STEP 5: CHECK THE INSTALLATION
Check the installation of each steamer, as follows:
1. Check that all screws and bolts are tightened.
2. Check that the electrical connection has been made correctly.
3. Check that the steamer is level. If not, adjust the legs (or level the countertop surface).
4. Check that the appropriate minimum clearances are satisfied (see page 4).
5. Check the door for proper alignment, and that it opens and closes properly.
6. Check that there is sufficient clearance in front of the steamer to open the door and to pull out the pans.
7. Wipe clean all surfaces.
STEP 6: CHECK STEAMER OPERATION
Check the operation of each steamer, as follows:
1. Fill tank with water.
2. Turn on the electric power supply.
3. Move the ON/OFF lever to the “ON” position and check that the Power light comes on.
4. Check that the timer and buzzer operate correctly.
5. Open the door and check that water is entering the cavity (NOTE: The fill rate is slow).
6. Wait four minutes, then check that some water has covered the bottom of the cavity.
7. Depress the door-switch actuator rod and listen for an audible “click.” Release the door-switch actuator rod
and listen for another audible “click.” (The clicks indicate that the contactor is functioning properly.)
8. Check that steam is escaping from the vent at the top left rear corner of the steamer.
9. Move the ON/OFF lever to the “OFF” position and check that the Power light goes out. Also check that the
water is draining correctly into the drain, and that the steamer completely drains.
STEP 7: SHUT-DOWN AND WIPE-CLEAN STEAMER
Complete the installation by leaving the steamer ready for customer use:
1. Allow the steamer to cool.
2. Wipe clean all surfaces.
3. Unless the steamer is to be placed in service immediately, turn off the electric power supply.
4. Make sure that a copy of this manual will be available to the people who will operate and maintain the
steamer.
OWNER’S MANUAL 1185184
PAGE 17 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
WARNING
ADJUSTMENTS AND SERVICE WORK MAY BE PERFORMED ONLY BY A QUALIFIED TECHNICIAN WHO IS
EXPERIENCED IN, AND KNOWLEDGEABLE WITH, THE OPERATION OF COMMERCIAL COOKING
EQUIPMENT. TO ASSURE YOUR CONFIDENCE, CONTACT YOUR AUTHORIZED SERVICE AGENCY FOR
RELIABLE SERVICE, DEPENDABLE ADVICE OR OTHER ASSISTANCE, AND FOR GENUINE FACTORY
PARTS.
NOTICE
INSTALLATION OF OTHER THAN GENUINE SOUTHBEND PARTS WILL VOID THE WARRANTY ON THIS
EQUIPMENT.
A serial plate is located on the right side of the steamer, near the top right corner. A second serial plate is located on
the rear of the steamer near the top left corner (see Figure 1).
Replacement parts (including parts not listed in this manual) may be ordered either through a Southbend Authorized
Parts Distributor or a Southbend Authorized Service Agency.
When ordering parts, please supply the Model Number, Serial Number, Part Number, and Part Description.
This section contains troubleshooting flowcharts, procedures, and electric schematics to assist a qualified service
technician in the servicing of a StratoSteam countertop steamer.
A description of how the steamer operates appears on the next page.
To remove a side panel (for access to the interior), remove the securing screw near the center of the bottom edge of
the panel. To remove the top panel, remove the two securing screws on the rear face, then slide the top panel forward
and off.
The door is field-reversible (contact Southbend for instructions).
TROUBLESHOOTING FLOWCHARTS, PROCEDURES, AND WIRING DIAGRAMS
Find the symptom below that corresponds to the malfunction, then turn to the corresponding page. Follow the
flowchart on that page until the problem is solved.
Troubleshooting Flowchart, Procedure, or Wiring Diagram
Page
Troubleshooting Flowchart: Steamer Not Heating Up, “Power” Light Is Not Lit
Troubleshooting Flowchart: Steamer Not Heating Up Properly or Not Cooking Properly, “Power” Light is Lit
Troubleshooting Flowchart: Buzzer Does Not Come On When Timer Runs Out
Troubleshooting Procedure: Heating Cartridge Check (at Contactor)
Troubleshooting Procedure: Power Switch Check
21
22
23
24
25
26
27
28
29
30
31
32
Troubleshooting Procedure: Contactor Check
Troubleshooting Procedure: Timer and Buzzer Check
Troubleshooting Procedure: Door Switch Check
Troubleshooting Procedure: High Limit Thermostats Check
Troubleshooting Procedure: Water-Level-Control Sensor Check
Troubleshooting Procedure: Water Solenoid Check
Wiring Diagram for 208/220/240 Volt Models
PAGE 18 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
HOW THE STEAMER OPERATES
The steamer is a manual fill, “connectionless” steamer. The internal components of the steamer are shown in
Figure 8.
The only utility required for operation is electrical power. The unit is available in 208, 220, and 240V single or
three phase.
To fill the unit approximately 3.0 gallons of water should be poured into the trough just above the door. Water can also
be poured directly into the cavity, if desired.
Water poured into the upper trough will fill the reservoir tank at the top of the steamer. This water is gravity fed
through a solenoid valve that is controlled by a time delay relay that is controlled by a capacitive discharge water level
sensor on the side of the tank. As the water level in the interior of the steamer drops below the midpoint of the sensor
the level switch will close. After 30 seconds of continuous close the time delay relay will trip closing the circuit to the
water solenoid. The water solenoid will be energized opening the valve to allow water to flow from the tank into the
cavity. Water will continue to fill the cavity until the water level sensor has opened and remained open for 30 seconds.
A pressure switch is located on the right side toward the rear of the control compartment. The high pressure side of
the switch is open to the interior of the cavity, the low pressure side is open to atmosphere. When the cavity pressure
rises, because the product is absorbing energy from the steam the interior pressure will rise. When the interior
pressure reaches approximately 3″ W.C. the switch shuts off power to the contactor coil, which shuts off power to the
heating elements. This is intended to reduce consumption of water. When the reservoir is full (3.0 gallons) the
steamer will operate for 4 hours in an empty cavity.
Any excess steam is vented out the pressure-relief valve located at the top left rear corner of the steamer. The dial
thermometer on the control panel is connected by a capillary tube to the sensor bulb located in the pressure-relief
vent. The thermometer does not affect the operation of the steamer.
A mechanical timer activates when the timer times out. The timer does not affect anything else! When the control
valve is turned to OFF, power to the electronic circuitry is turned off, which de-energizes the contactor and shuts off
the heating cartridges. Turning the control lever to OFF also de-energizes the water solenoid (turning off the water)
and mechanically opens the drain valve, permitting all water to drain from the bottom of the cooking cavity into the
drain pan.
OWNER’S MANUAL 1185184
PAGE 19 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
STRATOSTEAM COUNTERTOP STEAMER
Figure 8
How the Steamer Operates
PAGE 20 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 9
Steamer Not Heating Up, “Power” Light Is Not Lit
Steamer not heating up, “Power” light not lit.
DISCONNECT POWER AT CIRCUIT BREAKER
Remove right side panel for access.
Reconnect power at circuit breaker.
Turn lever to “ON” position and close door (to actuate door switch).
Check voltage between terminals L1 and L3 on contactor
(see page 26).
Is measured
voltage 208, 220, or 240
volts?
No
Yes
DISCONNECT POWER AT CIRCUIT BREAKER
Test operation of power switch (see page 25). Replace if
necessary. If power switch is OK, replace “Power” light and follow
procedure on page 22.
Check resistance between heating-cartridge contactor terminals
as described on page 24.
Is measured resistance
in the range specified on
page 24?
No
Yes
Disconnect all the heating
cartridges from the contactor.
Measure the resistance across
the leads each cartridge.
Replace any cartridge that
shows either an open or short
circuit.
Cartridges are OK
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
PAGE 21 OF 44
SERVICE
Figure 10
STRATOSTEAM COUNTERTOP STEAMER
Steamer Not Heating Up Properly or Not Cooking Properly, “Power” Light is Lit
Steamer not heating properly or not cooking properly,
“Power” light is lit.
Turn off steamer and check that it drains completely. If steamer
does not drain, check drain path for obstructions. Fill steamer
reservoir. Turn steamer back on and wait 10 minutes.
Is water level at
normal level in cavity?
No
Yes
DISCONNECT POWER AT CIRCUIT BREAKER
DISCONNECT POWER AT CIRCUIT BREAKER
Check door switch (see page 28).
Check high-limit thermostats (see page 29).
Door switch OK?
No
High-limit thermostats OK?
Yes
No
Yes
Replace door switch.
Replace high-limit
thermostats as necessary.
Reconnect door switch lead wires.
Check water solenoid (see page 31).
Check resistance between heating-cartridge contactor terminals
and replace heating cartridges as necessary (see page 24).
Check water-level control sensor (see page 30).
Water solenoid OK?
No
Yes
Water-level control
No
Yes
Replace water solenoid.
Check for loose or broken
wires (see wiring diagram).
If wiring is OK, remove screen
from strainer and clean or
replace as necessary.
Reassemble, reconnect, and
recheck the steamer. If water
still does not enter the
steamer, examine the water
solenoid and inline Y strainer
for obstructions or deposits.
Clean or replace as
sensor OK?
Replace water-level
control sensor.
Check contactor (see page 26).
Contactor OK?
No
Yes
necessary.
Replace contactor.
Check for loose or broken
wires (see wiring diagram).
If wiring is OK, check that
heating cartridges are secure
(tighten to 75 inch-pounds of
torque).
PAGE 22 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 11
Buzzer Does Not Come On When Timer Runs Out
Buzzer does not come on when timer runs out.
DISCONNECT POWER AT CIRCUIT BREAKER
Remove right side panel for access.
Set timer for 5 minutes.
No
Does timer time down?
Yes
Replace timer.
Disconnect buzzer lead wires from the timer.
Check the timer (see page 27).
Timer OK?
No
Yes
Replace timer.
Replace buzzer.
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
PAGE 23 OF 44
SERVICE
Figure 12
STRATOSTEAM COUNTERTOP STEAMER
Heating Cartridge Check (at Contactor)
L1
L2
L3
Top of
Steamer
Ohms
A
B
C
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Turn Control Lever to OFF.
3. Remove right side panel of steamer.
4. DO NOT DISCONNECT HEATING-CARTRIDGE LEAD WIRES FOR THIS TEST.
5. Using a multimeter, check the resistance across contactor terminals as specified in the following table:
Model STRE-3EZ
Allowable Resistance (Ohms)
Three-Phase
Model STRE-5EZ
Allowable Resistance (Ohms)
Three-Phase
Serial-
Plate
Voltage
Single-Phase
A-C
Single-Phase
A-C
A-B and B-C
A-C
A-B and B-C
A-C
208
220
240
10 to 12
12 to 13
14 to 16
14 to 16
15 to 18
18 to 21
5 to 6
8 to 10
9 to 11
11 to 13
11 to 13
13 to 15
15 to 17
4 to 5
6 to 7
5 to 6
7 to 9
6 to 7
6. If the measured resistance at the contactor is not in the specified range, disconnect all the heating cartridges
from the contactor. Measure the resistance across the leads each cartridge. Replace any cartridge that
shows either an open or short circuit.
PAGE 24 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 13
Power Switch Check
Connector
Connector
PL1
Connector
PL1
PL1
Continuity
Continuity
(socket half)
(socket half)
(socket half)
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
6
L1
L2
L3
L1
L2
L3
No Continuity
Contactor
Test-Lead Positions
for Steps 5 to 7
Test-Lead Positions
for Step 8
Test-Lead Positions
for Step 9
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove right side panel.
3. Turn control lever from OFF to ON and then from ON to OFF while looking to see that the power switch is
properly actuating when the lever moves.
4. Disconnect the connector (PL1) that connects the control-panel component wires to the wiring harness.
5. As shown above, place one test lead on terminal L1 of the contactor and the other test lead in position 1 of
connector PL1 (the socket half, which is wired to the control panel).
6. Check for continuity with control lever in OFF position (there should not be continuity).
7. Check for continuity with control lever in ON position (there should be continuity).
8. Repeat steps 5 through 7 with one test lead on terminal L3 of the contactor and the other test lead in position
2 of connector PL1 (as shown above).
9. Place one test lead on PL1 position 1 and the other test lead on PL1 position 2 (as shown above). Check for
continuity with control lever in the ON position (there should not be continuity).
10. If continuity checks are incorrect, replace power switch.
11. Reconnect lead wires.
OWNER’S MANUAL 1185184
PAGE 25 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
Figure 14
STRATOSTEAM COUNTERTOP STEAMER
Contactor Check
Top of
Steamer
L1
L2
L3
Ohms
Actuator
Button
No Continuity
A
B
C
View Looking Down
Behind Contactor
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove right side panel.
3. Depress actuator on top of contactor. Actuator should travel freely and spring back when released.
4. Check for continuity between contacts L1 and A as shown above. There should be no continuity.
5. Repeat Step 4 for contacts L2 and B and for contacts L3 and C.
6. Remove wires B3 and B9 from contactor coil.
7. Place test leads on contactor coil terminals as shown in “View Looking Down” shown above and check
resistance
8. If resistance is not in the range 350 to 425 Ω, replace contactor.
9. Reconnect all wires.
PAGE 26 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 15
Timer and Buzzer Check
Continuity
1
3
Timer
Ohms
Buzzer
Inside of Control Panel
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove right side panel.
3. Set timer for one minute and allow to time out. If timer does not run, then replace timer.
4. Disconnect from the timer the wire that leads to the buzzer.
5. Disconnect connector PL1 to separate the other buzzer lead wire from the wiring harness.
6. Place test leads between positions 1 and 3 on the timer (as shown above).
7. Check for continuity when the timer has run down (so the buzzer should be on). If no continuity, replace timer.
8. Disconnect other lead wire from buzzer. Place test leads in terminals of buzzer lead wires (as shown above).
9. Check that resistance is approximately 3400 Ω. If it is not, replace the buzzer.
10. Reconnect wires.
OWNER’S MANUAL 1185184
PAGE 27 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
Figure 16
STRATOSTEAM COUNTERTOP STEAMER
Door Switch Check
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove right side panel.
3. Open and close the steamer’s door while looking to see that the door switch actuator rod actuates the door
switch when the rod moves.
4. Disconnect the wiring harness from the switch terminals at the two places shown above (where the test-probe
tips are located).
5. Place the test probes on the switch terminals (as shown above).
6. Check for continuity with the door open (there should NOT be continuity).
7. Check for continuity when the door is closed (there should be continuity).
8. If the continuity checks are not correct, replace the door switch.
9. Reconnect the wiring harness to the switch terminals.
PAGE 28 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 17
High-Limit Thermostats Check
1. Allow cavity bottom to cool before performing this test.
2. DISCONNECT POWER AT CIRCUIT BREAKER.
3. Remove left side panel.
4. Disconnect wire B4 from left side of high-limit thermostat.
5. Disconnect wire B5 from right side of high-limit thermostat.
6. Disconnect remaining high-limit thermostat wires B11 and B12.
7. Test each high-limit thermostat for continuity (as shown above). There should be continuity when the
thermostat is cool. Replace as necessary.
8. Reconnect wires.
OWNER’S MANUAL 1185184
PAGE 29 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
Figure 18
STRATOSTEAM COUNTERTOP STEAMER
Water-Level-Control Sensor Check
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove the left and right side panels.
3. Remove bottom panel (four screws).
4. Remove insulation cover panel (four nuts).
5. Locate the water-level-control sensor (at the rear edge of the rear element block). Disconnect wires B1 and B2
from the sensor.
6. Place test leads across water-level-control sensor terminals (as shown above) and check for continuity when
the sensor is cool. If no continuity, replace sensor.
7. Reconnect wires and reassemble.
PAGE 30 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 19
Water Solenoid Check
1. DISCONNECT POWER AT CIRCUIT BREAKER.
2. Remove right side panel.
3. Disconnect wires B6 and B7 from water solenoid lead wires.
4. Place test probes into water solenoid lead wires as shown above.
5. Resistance should be approximately 800 Ω. Replace if necessary.
6. Apply waterline pressure to water inlet. Water should not leak out of the compression fittings. If necessary,
replace water solenoid. Check to see that water is slowly running into the cooking cavity.
7. Reconnect solenoid lead wires and reconnect power to steamer. When power is turned on with the steamer
cool, the solenoid should “click.” If no click is heard, test for 200 to 240 volts on wires B6 and B7. If 200 to 240
volts is present and the water solenoid does not click, replace water solenoid.
OWNER’S MANUAL 1185184
PAGE 31 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
Figure 20
STRATOSTEAM COUNTERTOP STEAMER
Wiring Diagram for 208/220/240 Volt Models
PAGE 32 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 21
Wiring Diagram for 480 Volt Models
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
PAGE 33 OF 44
SERVICE
STRATOSTEAM COUNTERTOP STEAMER
PARTS
The following parts diagrams list and show serviceable parts. For parts not listed, contact a Southbend Authorized
Parts Distributor or a Southbend Authorized Service Agency.
Parts Diagram
Page
Structural Parts
35
37
39
40
40
41
42
Door Assembly Parts
Door Switch Parts
Control Panel Parts
Heating Cartridges, Thermostats, and Contactor Parts
Water Train Parts
Cabinet Base Parts
PAGE 34 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Structural Parts
See drawing on following page.
Quantity*
Key Part Number
Description
3EZ 5EZ
STRE-3 DOOR ASSEMBLY (see page 377 for individual parts)
STRE-5 DOOR ASSEMBLY (see page 377 for individual parts)
DRIP PAN
1
1185026
1185122
1185016
1185115
1185135
1185072
1185036
1185103
1185123
1178668
1178664
1178663
1178669
1185019
1185137
1
-
-
1
1
-
2
3
1
1
-
DOOR GASKET, STRE-3
DOOR GASKET, STRE-5
1
1
1
-
DOOR SWITCH ASSEMBLY (see page 388 for individual parts)
FLOOR PANEL
4
5
6
1
1
1
-
SIDEWALL ASSEMBLY STRE-3
SIDEWALL ASSEMBLY STRE-5
PAN GUIDE, LEFT SIDE, STRE-3
PAN GUIDE, LEFT SIDE, STRE-5
PAN GUIDE, RIGHT SIDE, STRE-3
PAN GUIDE, RIGHT SIDE, STRE-5
SIDE PANEL, LEFT OR RIGHT STRE-3
SIDE PANEL, LEFT OR RIGHT STRE-5
TOP PANEL W/A STRE-EZ
1
-
7
8
9
1
-
1
-
1
-
1
-
2
-
2
1
2
-
10 1189315
11 1-2476
12 1185042
1185138
1
2
1
-
PLUG, BUTTON, ZN PLATED, 5/8"
REAR INSULATING COVER STRE-3
REAR INSULATING COVER STRE-5
REAR PANEL ASSEMBLY STRE-3
REAR PANEL ASSEMBLY STRE-5
COVER, SIDE INSULATION STRE-3
COVER, SIDE INSULATION STRE-5
BRACKET, CONT S/A
1
-
13 1185075
1185121
1
-
1
-
14 1185189
1185192
1
-
1
1
1
1
1
2
2
2
2
1
1
15 1185078
16 1185172
17 1185067
18 1185185
19 1178485
20 1178486
21 1188948
22 11889462
23 1178410
24 1189032
1
1
1
1
2
2
2
2
1
1
WIRING SUPPORT BRACKET
BOTTOM PANEL ASSEMBLY
PANEL, COVER BOTTOM INSULATION
FRONT LEG
REAR LEG
BRACKET LEG
PAN GUIDE BRACKETS
PAN ASSEMBLY
PLATE REAR DRAIN BLANK
* Quantity of part used may depend on model (STRE-3EZ or SRTE-5EZ).
OWNER’S MANUAL 1185184
PAGE 35 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
Figure 22
STRATOSTEAM COUNTERTOP STEAMER
Structural Parts
See parts list on previous page.
PAGE 36 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 23
Door Assembly Parts
Note: The entire door, assembled, can be ordered (see page 35).
Key Part Number Qty Description
LATCH ASSEMBLY
1
2
3
4
5
1177317
1177344
1146527
1146526
1185053
1185124
1185028
1185115
1185135
1146268
6600412
1
4
6
4
1
1
2
1
1
2
2
1
1
1
2
1
1
1
1
8
1
1
4
4
SCREW, #10-24 × 3/4 SLOTTED HEX
WASHER #10 LOCK, SS, 300
WASHER, #10, FLAT
PANEL W/A, STR-3
PANEL W/A, STR-5
HINGE PLATE W/A
6
7
GASKET, DOOR STR-3
GASKET, DOOR STR-5
BOLT, 1/4-20 × 5/8 HEX HEAD, SS
LOCK WASHER, SS
8
9
RETAINER
10 1177086
11 1185088
12 PH-423
13 PH-292
14 1185029
1181018
DOOR HINGE BRACKET
FLANGE BUSHING, 1/4 ID BRONZE
NYLON WASHER, 1/4 × 1/2 × 1/8
INSULATION, DOOR STR-3
INSULATION, DOOR STR-5
SUPPORT W/A , DOOR GASKET STR-3
SUPPORT, DOOR GASKET STR-5
SCREW, 6-32 × 3/4, SELF TAP
RETAINER, DOOR GASKET STR-3
RETAINER, DOOR GASKET STR-5
WASHER, FLAT #10
15 1185023
1185128
16 1173254
17 1185118
1185136
18 1180460
19 1173224
SCREW, 1/2-20 × 5/8 S, SLOT TRS
OWNER’S MANUAL 1185184
PAGE 37 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
Figure 24
STRATOSTEAM COUNTERTOP STEAMER
Door Switch Parts
5
2
3
4
1
6
8
7
Note: The entire door switch, assembled, can be ordered (see page 35).
Key Part Number Qty Description
ARM, DOOR SW SWING STRATOSTEAM
BRACKET W/A, STRATOSTEAM, DOOR SWITCH
SWITCH, DOOR, SPDT, 15 AMP SUBMINIATURE
SCREW, 6-32 × 1 ROUND HEAD
1
2
3
4
5
6
7
8
1185070
1185071
1185195
1146320
1177081
1177082
PH-292
1
1
1
2
1
1
1
1
PIN, .250 DIA, SS, CAST LATCH STEAMER
SPRING, DOOR HANDLE
NYLON WASHER, 1/4 × 1/2 × 1/8
RING, RETAINING S.S. COMBI
6600402
PAGE 38 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 25
Control Panel Parts
Key Part Number Qty Description
CONTROL PANEL ASSEMBLY (assembled)
KNOB
1-17 1185039
1
1
1
1
1
2
1
1
1
1
1
1
2
2
1
2
1
1
1
1
1
1
1
2
3
4
5
6
7
8
9
1170337
1188947
1189024
1185205
1170350
1178388
1177770
1177865
1178276
POLYPANEL, CONTROL
PANEL, CONTROL W/A
GAUGE, THERMOMETER 2 IN
LIGHT, AMBER 240V SIGNAL
VALVE LEVER W/A
BUSHING, VALVE LEVER MOUNT
NUT, HEX, 5/8-18, BRASS
CAM ACTUATOR
SCREW, SET
10 1178549
11 1185056
12 1183429
13 6600430
14 1178535
15 1146320
16 1175712
17 1178341
18 1185080
19 1185031
20 1178393
BRACKET, ON/OFF SWITCH
INSERT, KNURLED
LOCKNUT
SWITCH, POWER
SCREW, 6-32 × 1 ROUND HD
BUZZER ASSEMBLY
TIMER, MECHANICAL
GASKET, CONTROL PANEL
VALVE ACTUATION ROD
1/8 × 1 1/4 18-8 COTTER PIN
WIRING HARNESS
*
1185161
* Not shown on drawing.
OWNER’S MANUAL 1185184
PAGE 39 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
Figure 26
STRATOSTEAM COUNTERTOP STEAMER
Heating Cartridges, Thermostats, and Contactor Parts
Quantity*
Key Part Number
Description
3EZ 5EZ
CONTACTOR 208-240V
1
2
1181032
1181501
1181771
1181502
1181772
1181503
1181773
1181504
1181774
1185197
1185177
1
6
-
1
-
HEATER CARTRIDGE, 208V 60HZ (for Model STRE-3)
HEATER CARTRIDGE, 208V 60HZ (for Model STRE-5)
HEATER CARTRIDGE, 220V 50/60HZ (for Model STRE-3)
HEATER CARTRIDGE, 220V 50/60HZ (for Model STRE-5)
HEATER CARTRIDGE, 240V 60HZ (for Model STRE-3)
HEATER CARTRIDGE, 240V 60HZ (for Model STRE-5)
HEATER CARTRIDGE, 480V 60HZ (for Model STRE-3)
HEATER CARTRIDGE, 480V 60HZ (for Model STRE-5)
HIGH TEMP LIMIT THERMOSTAT
6
-
6
-
6
-
6
-
6
-
6
-
6
3
1
3
4
3
1
CONTROL THERMOSTAT
* Quantity of part used may depend on model (STRE-3EZ or SRTE-5EZ).
PAGE 40 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 27
Water-Train Parts
See parts list on previous page.
Water Train Parts
See drawing on following page.
Key Part Number Qty Description
FITTING, 1/8NPT × 3/8CC STRAIGHT
TUBE, FLEX .375 × 18″
1
1176385
1185292
1184260
1176384
1174933
1187477
1189315
1189314
1178552
4
1
1
1
1
1
1
1
1
1
1
1
1
1
1
2
3
4
5
6
7
8
9
STRAINER, Y IN-LINE 1/8″ NPTF
NIPPLE, CLOSE 1/8NPT, 3/4″ LONG
VALVE, 240/60 SOLENOID
TUBE, FLEX .375 × 5
TOP PANEL W/A STRE-EZ
COVER, WATER TANK STRE-EZ
COVER W/A, DRAIN, EZ-3
MOUNTING WELL, WATER LVL SENSR
LEVEL SENSOR, WTR, CAPACATIVE
RELAY, TIME DELAY
10 1189006
11 1189005
12 1189022
13 1185106
14 1146910
15 1146805
VALVE, DRAIN STR STEAMER
ELBOW, STREET, BLK, 3/4″, 90 DEG
NIPPLE, PIPE, BLK, 3/4″ × 5″
OWNER’S MANUAL 1185184
PAGE 41 OF 44
Download from Www.Somanuals.com. All Manuals Search And Download.
SERVICE
STRATOSTEAM COUNTERTOP STEAMER
Cabinet Base Parts
See drawing on following page.
Key Part Number Qty Description
PANEL, 12" SS DOOR
1
2
3
*
1188933
1188934
1183987
1182637
1183985
1183983
1183984
1183986
1184527
1185144
1188936
2
2
LINING, 12" SS DOOR
HANDLE, CATCH DOOR
2
CATCH, MAGNETIC, SGS
2
HINGE ASSEMBLY, UPPER LEFT
HINGE ASSEMBLY, UPPER RIGHT
HINGE ASEMBLY, LOWER RIGHT
HINGE ASSEMBLY, LOWER LEFT
COVER, 24" BASE BOTTOM
PANEL, TOP CABINET
4
5
6
*
1
1
1
1
7
8
9
1
1
BODY BACK, 12" CABINET
1
BODY SIDE, 12" CABINET
10 1188935
11 1172650
12 1146500
13 1146201
14 1174260
2
LEG PAD (3/4 X 10 HOLE)
4
1/4 LOCK WASHER
16
16
1
1/4 X 30 X 3/4 HEX HEAD
LEG PACKAGE (set of four legs, not including bolts, leg pads, or lock washers)
EARTHQUAKE LEGS SS (set of four)
*
1174262
1
* Not shown on drawing.
PAGE 42 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
STRATOSTEAM COUNTERTOP STEAMER
SERVICE
Figure 28
Cabinet-Base Parts
See parts list on previous page.
9
10
8
1
2
4
3
5
7
11
6
12
13
14
15
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
PAGE 43 OF 44
STRATOSTEAM COUNTERTOP STEAMER
StratoSteam
Countertop Steamer
Models STRE-3EZ and STRE-5EZ
A product with the Southbend name incorporates the best in durability and low maintenance. We all recognize,
however, that replacement parts and occasional professional service may be necessary to extend the useful life of
this appliance. When service is needed, contact a Southbend Authorized Service Agency, or your dealer. To avoid
confusion, always refer to the model number, serial number, and type of your appliance.
Southbend
1100 Old Honeycutt Road, Fuquay-Varina, NC 27526
PAGE 44 OF 44
OWNER’S MANUAL 1185184
Download from Www.Somanuals.com. All Manuals Search And Download.
|
Sharp Fax Machine FO 2970M User Manual
Sharp Printer AR M450 User Manual
Sharp Projector XG F210X User Manual
Snapper Lawn Mower ZT18440KH User Manual
Sony CRT Television KV J14P2S User Manual
Sony Projector ES7 User Manual
Southbend Lathe SB1314 User Manual
SOYO Computer Hardware SY K7VEMPRO User Manual
Speco Technologies Computer Monitor VM 1201 User Manual
SVA Flat Panel Television ED4228P User Manual