3-776-792-12(1)
Remote Control
Panel
Operating Instructions
Before operating the unit, please read this manual
thoroughly and retain it for future reference.
RCP-D50/D51
2004 by Sony Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Overview ............................................................................4
Features ............................................................................... 4
Locations and Functions of Parts ...................................5
Operation Panel ................................................................... 5
Connector Panel ................................................................ 13
Mounting on a Console ..................................................14
Menu Configuration and Basic Menu Operations........ 15
Basic Operating Procedure ................................................ 15
Basic Configuration of Menu Display .............................. 16
Menu Items with the DXC-D50-Series Cameras .............. 20
Menu Items with the DXC-D30/D35-Series Cameras ...... 27
Menu Items with the DXC-637-Series Cameras ............... 34
Menu Items with the CCU-TX50 ...................................... 38
Initial Settings..................................................................45
Setting the Operating Conditions of the RCP-D50/D51 ... 45
Setting the Built-in Clock.................................................. 45
Adjusting the Buzzer Sound.............................................. 46
Adjusting the Brightness of the LEDs............................... 47
Changing the Functions of the Rotary Encoders............... 47
Adjusting the Brightness/Contrast of the LCD ................. 48
Assigning a Function to the ASSIGN Button.................... 48
Specifying the Security Codes .......................................... 49
File Operations ................................................................51
Operating Scene Files........................................................ 53
Transferring Scene Files between the Camera and
a Memory Stick (with the DXC-D50 Series) ............... 54
Operating Setup Files (for DXC-D30/D35 Series only) ... 55
Skin Detail Correction/Skin Matrix Adjustment
(for DXC-D30/D35/D50 Series Only) .....................56
Multi-Camera Control......................................................57
Connections and Preparatons ............................................ 57
Adjusting the Iris/Master Black of Multiple Cameras
at One Time .................................................................. 57
Data Transfer Among Multiple Cameras .......................... 57
Operating Multiple Cameras from One RCP Unit —
Command Link............................................................. 58
Memory Sticks.................................................................59
Using a Memory Stick....................................................... 59
Notes on Memory Stick..................................................... 59
Specifications..................................................................61
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Overview
The RCP-D50/D51 Remote Control Panel enables
remote operation of the DXC-D50-series, DXC-D30/
D35-series,or DXC-637-series Color Video Cameras.
Confirmation of camera conditions and
operation status
This unit’s LCD panel indicates camera conditions
such as the optical filter position, value, and lens
extender setting. The results of the camera’s self-
diagnosis tests are also displayed on the LCD panel.
The RCP-D50 and RCP-D51 are completely identical
in their functions except with respect to the iris and
master black adjustments.
For the iris and master black adjustments, the RCP-
D50 uses a joystick type control while the RCP-D51
uses rotary knobs.
Signal transmission via a digital line
Between this remote control panel and the camera
control unit, signals are digitally transmitted via a
single connection cable (CCA-7), ensuring a reliable
signal. Operating power is also supplied via the cable.
Features
Optimal control parts arrangement for
basic camera operation
Memory Stick slot
Various data, including scene files, can be stored on a
Memory Stick and reproduced at any time.
This remote control panel is provided with essential
control functions for basic operation of a camera.
The buttons, knobs, and other controls have been
arranged according to their functions and with
consideration to their frequency of use. Indicators and
buttons light or flash to indicate the status of the
system operation. Also, guard frames are provided to
protect against accidental use of those buttons vital to
camera operation. These features ensure easy and
error-free use of this remote control panel.
Touch panel with 31/2-inch LCD for various
operations
The control panel has a touch panel that permits
various items to be selected and adjusted on the LCD
in menu format. (The menu items differ among the
cameras to be connected.)
Full control of shooting operations
Video display function
Besides controlling camera adjustments and settings,
this unit can control tripod operations (pan and tilt) and
lens settings (focus and zoom).
The LCD can also display pictures from the connected
camera, permitting you to use it as a convenient video
monitor.
Scene file
Four units mountable on a 19-inch rack
The unit provides memory to hold data on shooting
conditions for 20 different scenes, to enable easy
readjustment of the camera for any memorized scenes.
(When a DXC-D50-series camera is connected, data
are held in memory of the camera.)
Up to four units of this control panel can be mounted
in a line on a 19-inch EIA standard rack.
Coordination of settings among several
cameras
In a system that includes several cameras that are
connected via CCUs, connecting the CCUs allows this
unit to set up all of the cameras into the same color
condition.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Locations and Functions of Parts
Operation Panel
1 MASTER and SLAVE buttons
qa ASSIGN button
qs Power and output select buttons
MASTER SLAVE ASSIGN
CAM PW
AUTO SETUP
BARS
CLOSE
2 PREVIEW button
qd AUTO SETUP buttons
3 STANDARD button
SKIN DTL LEVEL START
SET UP
PREVIEW
STANDARD
WHITE BLACK
qf White balance control buttons
4 Camera/CCU function
5600K
AUTO
KNEE
SKIN
DETAIL PRESET
GATE
A
B
DETAIL
WHITE
ON/OFF buttons
PAINT1 PAINT2 PAINT3 SCENE OTHERS FUNCTION MONITOR
MENU
Menu operation block (page 9)
MONITOR
BRIGHT
CONTRAST
qg MASTER GAMMA knob
qh DETAIL knob
5 WHITE knobs
MASTER
GAMMA
DETAIL
WHITE
6 BLACK/FLARE knobs and
indicator
qj MEMORY STICK slot and
access lamp
BLACK/FLARE
a
EXT
7 Camera number/tally indication
window
IRIS/M.BLACK
ACTIVE
OPEN
IRIS/M.BLACK
LINK
MASTER
BLACK
SENS
AUTO
Iris/master black control block
(page 10)
RELATIVE
RELATIVE
CLOSE
COARSE
OPEN
8 ALARM indicator
ALARM
CALL
9 CALL button
PANEL
ACTIVE
0 PANEL ACTIVE button
IRIS
CLOSE
REMOTE CONTROL PANEL
RCP-D50
BLACK/FLARE
7 Camera number/tally indication
EXT
window
MASTER
BLACK
RELATIVE
IRIS/
M.BLACK
LINK
SENS
OPEN
CLOSE
COARSE
AUTO
Iris/master black control block
(page 12)
IRIS/M.BLACK
ACTIVE
8 ALARM indicator
ALARM
CALL
9 CALL button
PANEL
ACTIVE
0 PANEL ACTIVE button
IRIS
REMOTE CONTROL PANEL
RCP-D51
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Locations and Functions of Parts
1 MASTER and SLAVE buttons
5 WHITE (white balance manual adjustment)
knobs
Used to manually adjust the white balance.
The left knob is for the R signal and the right knob for
the B signal.
When adjusting the white balance of multiple cameras
in Master/Slave mode, designate the master camera or
the slave cameras. Press and light up the MASTER
button to specify the connected camera for the master.
Press and light up the SLAVE button to specify the
connected camera for the slave. The slave cameras
follow the master camera settings.
6 BLACK/FLARE (black balance/flare balance
manual adjustment) knobs and indicator
Used to manually adjust the black balance (when the
indicator is not lit) or the flare balance (when the
indicator is lit).
If you press a button when lit, it goes dark.
2 PREVIEW button
Press this button to control an external device
connected to the EXT I/O connector on the connector
panel.
For the operational specifications, see “3 EXT I/O
(external input/output) connector (9-pin)” in “Connector
Panel” on page 13.
From the left, the knobs are for R, G, and B signal
adjustment.
Selection between black balance and flare balance is
made using the OTHERS menu.
See “Changing the Functions of the Rotary Encoders” on
page 47.
3 STANDARD button
7 Camera number/tally indication window
The number of the camera being controlled from this
panel is displayed in orange.
When a red tally signal is sent to the camera, the
number is displayed in black and the background of
the number lights in red.
When you press this button, the video camera is
initialized to its standard state and the button lights for
several seconds.
If you press the button while it lights, the video camera
retrieves the state before the button was lit.
When a green tally signal is sent to the camera, the
number is displayed in black and the background of
the number lights in green.
When both the red and green tally signals are
simultaneously sent, the left half of the background
lights in red and the right half lights in green.
4 Camera/CCU function ON/OFF buttons
Various functions of the video camera or the CCU can
be turned on and off from this panel.
8 ALARM indicator
5600K
AUTO
KNEE
SKIN
DETAIL
DETAIL
GATE
Lights when trouble occurs in the camera system and
the self-diagnostic function activates at the video
camera or the CCU.
5600K (valid only with the DXC-D50 series):
5600K electric color temperature conversion
function
9 CALL button
When the camera is connected via a CCU, press to
send a call signal to the video camera, on which the
CALL button lights. The tally lamps on the camera
and the red tally lamp on the CCU light when not lit,
or go dark when lit.
When the CALL button on the video camera is
pressed, the CALL button on this panel lights and a
buzzer sounds.
AUTO KNEE: Auto knee function. When this button
is lit (ON), the knee point is automatically adjusted
according to the light content of the picture.
SKIN DETAIL: Skin detail function
DETAIL GATE: Skin detail gate function. When
this button is lit (ON), the adjustment range of the
skin tone detail is displayed in white on the
monitor screen.
For details on the Skin detail and Skin detail gate, see “Skin
Detail Correction/Skin Matrix Adjustment (for DXC-D30/
D35/D50-Series Only)” on page 56.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
0 PANEL ACTIVE button
C CLOSE button
Press and light up the button to permit this panel to
control the camera system (Panel active status).
The IRIS/M.BLACK ACTIVE button of the iris/
master black control block also lights.
If you press this button so that it goes dark, the panel
will be locked, preventing accidental misoperation.
If Panel Active Lock with a security code has been
enabled, the PANEL ACTIVE and the IRIS/
M.BLACK ACTIVE buttons are locked by pressing
the PANEL ACTIVE button for more than 2 seconds
in Panel active status.
Press and light the button to close the iris. To release
the close mode, press the button again so that it goes
dark.
The close mode is also released when you press the
STANDARD or IRIS/M.BLACK LINK button, or
operate a scene file.
qd AUTO SETUP buttons
A
B
C
D
For details on Panel Active Lock, see “Specifying the
Security Codes” on page 49.
AUTO SETUP
SKIN DTL LEVEL START
SET UP
WHITE BLACK
qa ASSIGN button
Various functions can be assigned to this button using
“SW Setting” of the RCP Config menu (No function is
assigned at the factory).
A Auto adjustment item select buttons
Press and light up these buttons to select the items to
be automatically adjusted.
To assign a function, see “Assigning a Function to the
ASSIGN Button” on page 48.
SKIN DTL SETUP: Skin detail
LEVEL: Gamma balance, knee point, master black
level, etc.
qs Power and output select buttons
For details on the Skin detail setup, see “Skin Detail
Correction/Skin Matrix Adjustment (for DXC-D30/D35/D50
Series Only)” on page 56.
B
A
C
B START button
CAM PW
BARS
CLOSE
Press to start automatic adjustment of the selected
items.
The button lights during adjustment and goes dark
when adjustment is completed.
A CAM PW (camera power) button
When the unit is connected to the CCU-TX7, you can
turn the power supply to the video camera ON by
pressing and lighting up this button. (The button
promptly flashes until the camera becomes ready for
transmission.)
C WHITE (white balance) button
Press to automatically adjust the white balance.
The button lights during adjustment and goes dark
when adjustment is completed.
When you press this button again, it starts flashing and
the power supply is turned off.
D BLACK (black balance) button
Press to automatically adjust the black balance and
black set.
The button lights during adjustment and goes dark
when adjustment is completed.
B BARS (color-bar signal) button
Press and light up this button to activate the color-bar
signal generator of the video camera and send the
respective the color-bar signal. When you press this
button again, the button goes dark and the camera
picture is displayed.
Note
If an error occurs during adjustment, the pressed
button flashes.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Locations and Functions of Parts
qf White balance control buttons
PRESET
A
B
WHITE
PRESET: Press and light this button to retrieve the
preset white balance of the camera.
A (memory A): Press and light this button to retrieve
the white balance stored in memory A of the
camera.
B (memory B) (valid only with the DXC-D50
series): Press and light this button to retrieve the
white balance stored in memory B of the camera.
Note
When the ATW (automatic tracing white balance)
function is active, the white balance control buttons are
not operative.
qg MASTER GAMMA knob
Used to adjust the master gamma.
qh DETAIL knob
Used to adjust the detail level.
qj MEMORY STICK slot and access lamp
Insert a Memory Stick to store setting data, such as
reference files and scene files of the video camera or
CCU.
The access lamp shows the status of the Memory
Stick.
Off: No Memory Stick is inserted.
Lit in green: There is a Memory Stick in the slot. In
this condition, you can safely eject the Memory
Stick.
Lit in red: Data are being read/written. If you eject
the Memory Stick in this condition, the data are
not guaranteed. All the data may be lost.
Note
If “Check Memory Stick” is displayed on the LCD in
the menu operation block, check that the Memory
Stick has sufficient unused storage space or it has been
properly formatted.
For details on Memory Sticks, see page 59.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
2 MONITOR button
Press this button to display the picture from the
connected camera on the LCD.
Menu operation block
Press the button again to return to the display of this
unit.
2
1
With a DXC-D50-series camera connected, eath time
you press the MONITOR button, the camera picture,
the camera picture with characters superimposed, and
the menu display of this unit are displayed in sequence
(When a CCU is used, the camera picture with
characters is not displayed).
PAINT 1 PAINT 2 PAINT 3 SCENE OTHERS
MENU
MONITOR
FUNCTION
If no camera picture is displayed with the CCU-TX7
connected, consult your Sony dealer.
3
3 LCD/touch panel
Normally displays the statuses (see page 16).
When you press a MENU button, the corresponding
menu is displayed to enable you to adjust the displayed
items.
When you press the MONITOR button, the picture
from the camera is displayed.
MONITOR
BRIGHT
CONTRAST
4
4 Control knobs (rotary encoders)
In Menu mode, adjust the selected items on the touch
panel.
1 MENU buttons
Select the menu mode.
When the picture from the camera is displayed on the
LCD (MONITOR button lit), you can adjust the
picture brightness with the second knob (BRIGHT)
from the left and the picture contrast with the third
knob (CONTRAST) from the left.
If you press and light one of these buttons, the menu
for the selected mode appears on the LCD.
PAINT 1/2/3: Each selects the Paint menu to adjust
various paint items, such as white, black, and flare.
The configuration of the Paint menu depends on
the connected camera. When Paint 4 and Paint 5
are available, you can select them by pressing v or
V on the Paint menu display (see page 16) or the
PAINT 3 button.
SCENE: Selects the File operation menu to register
and retrieve scene files.
OTHERS: Selects the OTHERS menu to set various
settings, such as operational conditions of this
control panel.
FUNCTION: Selects the Function menu to control
various camera and CCU functions.
For the items of each menu, see “Menu Configuration and
Basic Menu Operations” on page 15.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Locations and Functions of Parts
Iris/master black control block (RCP-D50)
3 IRIS/M.BLACK LINK button
4 IRIS/M.BLACK ACTIVE button
5 AUTO button
6 f-number display
7 EXT indicator
EXT
IRIS/M.BLACK
ACTIVE
OPEN
IRIS/M.BLACK
LINK
1 MASTER BLACK display
8 SENS control knob
MASTER
BLACK
SENS
AUTO
2 MASTER BLACK RELATIVE
button
9 COARSE control knob
RELATIVE
RELATIVE
CLOSE
OPEN
COARSE
0 Master black control ring
qa IRIS control lever
qs Preview switch
IRIS
CLOSE
qd IRIS RELATIVE button
1 MASTER BLACK display
Displays the current master black setting in the range
3 IRIS/M.BLACK LINK (iris/master black
adjustment link) button
from –99 to +99.
Press and light up the button to perform linked
adjustments of iris and master black for several
cameras.
For details, see “Adjusting the Iris/Master Black of Multiple
Cameras at One Time” on page 57.
2 MASTER BLACK RELATIVE button
When the IRIS/M.BLACK ACTIVE button is lit, the
master black adjustment mode can be selected with
this button.
4 IRIS/M.BLACK ACTIVE (iris/master black
active) button
Press and light up this button to enable the iris/master
black control block of the panel.
When the PANEL ACTIVE button is pressed, this
button also lights.
Press and light up the button for Relative mode, or
press and turn it dark for Absolute mode.
When the IRIS/M.BLACK ACTIVE button is not lit,
Relative mode is automatically selected and this button
is not operative.
Note
If you press this button so that it goes dark, the panel
will be locked, preventing accidental misoperation.
When VR STD MODE is set to Absolute with the VR
Setting of the RCP Config menu, Relative mode is not
selected even if you turn the IRIS/M.BLACK
ACTIVE button off. When you turn the IRIS/
M.BLACK ACTIVE button on, the master black value
corresponding to the position of the master black
control ring is restored.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
5 AUTO button
qd IRIS RELATIVE (iris relative) button
When the IRIS/M.BLACK ACTIVE button is lit, the
iris adjustment mode can be selected with this button.
Press and light up the button for Relative mode or
press so that it goes dark for Absolute mode.
When the IRIS/M.BLACK ACTIVE button is not lit,
Relative mode is automatically selected and this button
is not operative.
Press and light the button to automatically adjust the
iris according to the amount of input light.
When this button is lit, the reference value for
automatic iris adjustment can be set with the iris
control.
If you press the button when lit, it goes dark and
manual iris adjustment is enabled.
Note
6 f-number display
When VR STD MODE is set to Absolute with “VR
Setting” of the RCP Config menu, Relative mode is
not selected even if you turn the IRIS/M.BLACK
ACTIVE button off. When you turn the IRIS/
M.BLACK ACTIVE button on, the iris setting
corresponding to the IRIS lever position is restored.
Displays the f number of the current iris setting. When
the iris is closed, “CL” is displayed.
When the DXC-D50 series is connected, “OP” is
displayed for the maximum f-number value.
7 EXT (lens extender) indicator
Lights when the lens extender is used.
Iris adjustment functions
Relative mode
Absolute mode
8 SENS (sensitivity) control knob
Used for manual iris adjustment in Absolute mode.
This control is not operative when Relative mode is
selected.
(RELATIVE button lit)
(RELATIVE button not lit)
IRIS lever
Adjusts the iris with
Adjusts the iris
within the variable
(RCP-D50)/ relative values from
IRIS control OPEN to CLOSED.a) range set by the
(RCP-D51)
SENS and COARSE
controls.
See the table “Iris adjustment functions”to the right.
COARSE
control
Adjusts the total
range from OPEN
to CLOSED in relative
values.
Sets the lower limit
for CLOSED.
9 COARSE control knob
Used for manual iris adjustment.
See the table “Iris adjustment functions”to the right.
SENS
control
Does not function.
Sets the upper limit
for OPEN according
to CLOSED value
set by the COARSE
control.
0 Master black control ring
Turn to manually adjust the master black level.
qa IRIS control lever
When the AUTO button is not lit, you can adjust the
a) The adjustable range can be set with “VR Rel. Scale” of
the RCP Config menu.
iris manually by moving the lever.
When the AUTO button is lit, the reference value for
automatic iris adjustment can be set.
See the table “Iris adjustment functions” to the right.
qs Preview switch
Press this switch to control an external device
connected to the EXT I/O connector on the connector
panel.
For the operational specifications, see “3 EXT I/O
(external input/output) connector (9-pin)” in “Connector
Panel” on page 13.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Locations and Functions of Parts
Iris/master black control block (RCP-D51)
4 IRIS RELATIVE button
5 IRIS/M.BLACK LINK button
1 MASTER BLACK display
6 f-number display
EXT
7 EXT indicator
2 MASTER BLACK control
8 SENS control knob
9 COARSE control knob
MASTER
BLACK
IRIS/
M.BLACK
LINK
SENS
RELATIVE
OPEN
COARSE
CLOSE
3 IRIS/M.BLACK ACTIVE button
AUTO
IRIS/M.BLACK
ACTIVE
0 IRIS control
qa Iris gauge
IRIS
qs AUTO button
1 MASTER BLACK display
Note
Displays the current master black setting in the range
from –99 to +99.
When VR STD MODE is set to Absolute with “VR
Setting” of the RCP Config menu, Relative mode is
not selected even if you turn the IRIS/M.BLACK
ACTIVE button off. When you turn the IRIS/
M.BLACK ACTIVE button on, the iris setting
corresponding to the position of the IRIS control is
restored.
2 MASTER BLACK control
Manually adjust the master black level.
The setting is displayed in the MASTER BLACK
display.
3 IRIS/M.BLACK ACTIVE (iris/master black
active) button
Press and light up this button to enable the iris/master
black control block of the panel.
When the PANEL ACTIVE button is pressed, this
button also lights.
If you press this button so that it goes dark, the panel
will be locked, preventing accidental misoperation.
5 IRIS/M.BLACK LINK (iris/master black
adjustment link) button
Press and light up the button to perform linked
adjustments of iris and master black for several
cameras.
For details, see “Adjusting the Iris/Master Black of Multiple
Cameras at One Time” on page 57.
6 f-number display
Displays the f number of the current iris setting. When
the iris is closed, “CL” is displayed.
When the DXC-D50 series is connected, “OP” is
displayed for the maximum f-number value.
4 IRIS RELATIVE (iris relative) button
When the IRIS/M.BLACK ACTIVE button is lit, the
iris adjustment mode can be selected with this button.
Press and light up the button for Relative mode or
press so that it goes dark for Absolute mode.
When the IRIS/M.BLACK ACTIVE button is not lit,
Relative mode is automatically selected and this button
is not operative.
7 EXT (lens extender) indicator
Lights when the lens extender is used.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
8 SENS (sensitivity) control knob
Used for manual iris adjustment in Absolute mode.
This control is not operative when Relative mode is
selected.
Connector Panel
1 MONITOR connector
See the table “Iris adjustment functions”on page 11.
2 CCU/CAMERA connector
3 EXT I/O connector
9 COARSE control knob
Used for manual iris adjustment.
See the table “Iris adjustment functions” on page 11.
CCU/
CAMERA
MONITOR
EXT I/O
0 IRIS control
When the AUTO button is not lit, you can adjust the
iris manually by turning the control.
When the AUTO button is lit, the reference value for
automatic iris adjustment can be set with this control.
1 MONITOR connector (BNC type)
Connect to a video monitor.
See the table “Iris adjustment functions” on page 11.
2 CCU/CAMERA (camera control unit/camera)
connector (10-pin)
Connect to the REMOTE connector of a camera
control unit or a camera.
qa Iris gauge
Turn the gauge to set the line to the most frequently
used iris position, and it can be used as the reference
for manual iris adjustment.
3 EXT I/O (external input/output) connector
(9-pin)
This connector permits you to control an external
device using the PREVIEW button (page 6) or the
preview switch (page 11).
qs AUTO button
Press and light the button to automatically adjust the
iris according to the amount of input light.
When this button is lit, the reference value for
automatic iris adjustment can be set with the iris
control.
Operational specifications
If you press the button when lit, it goes dark and
manual iris adjustment is enabled.
While the PREVIEW button or the preview switch
(RCP-D50 only) is held pressed, pin 1 and pin 2 of the
EXT I/O connector are short-circuited.
Pin assignment of the EXT I/O connector
1
5
9
6
Caution
When installing this panel, provide a gap of 7 cm (3
inches) or more behind the connector panel to prevent
damage to cables.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Mounting on a Console
The RCP-D50/D51 can be mounted on a console as
shown below:
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
The RCP-D50/D51 provides menu operations for
various functions such as adjustments of system
equipment.
When the selected menu is composed of
multiple pages
With the menu that is composed of multiple pages
such as Paint menu, press v or V to flip the pages.
See “Initial display (Paint menu)” on the next page.
Basic Operating Procedure
When a submenu is shown
Press the desired submenu item to change the
display.
See “Submenu” on page 17.
1
3 Set or adjust the item (parameters).
FUNCTION MONITOR
PAINT 1 PAINT 2 PAINT 3 SCENE OTHERS
MENU
• Turn the control knobs (or press the button) to
adjust (or set) the corresponding item
(parameters) to the desired values.
See “Adjustment display” on page 17.
• When a message is displayed, follow the
instruction and press [OK].
2
3
When the adjustment is finished
• To adjust another item of the same menu, press the
names of that item.
• To adjust items of another menu, press the
corresponding MENU button.
MONITOR
BRIGHT
CONTRAST
• To release the menu operation mode, press the lit
MENU button.
• You may select Function menu without exiting the
currently selected menu. When you exit Function
menu by either of the following methods, the
previous menu is restored.
– Press the lit FUNCTION button so that it goes dark.
– Press the lit MENU button for the previous menu.
1 To display a menu, press and light one of the
MENU buttons.
The menu operation mode is initiated and the menu
for the pressed button appears on the display.
PAINT 1/2/3: Paint menu
SCENE: Scene file operation menu
OTHERS: OTHERS menu
To monitor the camera picture
Press the MONITOR button.
The picture from the connected camera is displayed on
the LCD.
FUNCTION: Function menu
With a DXC-D50-series camera connected, eath time
you press the MONITOR button, the camera picture,
the camera picture with characters superimposed, and
the menu display of this unit are displayed in
sequence. (When a CCU is used, the camera picture
with characters is not displayed.)
Note
The menu items to be displayed depends on the
connected camera.
2 Select the item to be adjusted.
Press the button that shows the name of the item on
the menu to obtain the corresponding adjustment
display or operation area.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Basic Configuration of Menu Display
Status display
When you do not select any menu or the signal from
the camera, the LCD shows the following status
display:
On the status display, the set value
of each item is only displayed. The
setting is made with the Function
menu or with the corresponding
knob on the operation panel.
The set values of the shutter and master gain
are displayed. You may adjust these items
using the Function menu.
The ND filter number being selected
on the camera is displayed.
Status
Shutter
M. Gain
Filter
60
12dB
1
When you select a scene file,
the filename is displayed.
Scene File : 2 DXC-D50
White
You may adjust these items using the
WHITE, MASTER GAMMA, BLACK/
FLARE, and DETAIL knobs, and IRIS
control (or IRIS lever).
Gamma
Detail
0
0
Black
0
0
Iris
The “Black” columns can be changed to
“Flare” using the OTHERS menu.
0
0
0
2
Initial display (Paint menu)
When you press and light the PAINT 1 (or PAINT 2,
PAINT 3) button of the menu operation block, the
initial display of the Paint menu is obtained.
Current page number / total number of pages
1 / 5
Clear
To clear the adjusted values
Press either to flip the pages of the
menu.
Gamma
/Knee
White
Black
Flare
The names of the items are
displayed. Press the name
of the item to be adjusted.
The color of the pressed
name area will change, and
the lower half of the panel
will become the adjustment
display (see the next page).
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Adjustment display (Paint menu)
When you select an item on the initial display of the
Paint menu, the lower half of the panel becomes the
adjustment display for the selected item.
Example: when you select “White” from the PAINT 1 initial display with the DXC-D50 series
connected
The name of the item selected on
the initial display is displayed.
If you press this area after pressing
[Clear], all the adjustment values for
the selected item are initialized to
standard.
Clear
White
1 / 5
Black
Flare
Gamma
/Knee
When you press this, the upper
half of the panel becomes the
monitor output setting display
(see page 19).
Monitor
Select
White
Memory
Preset
Memory
A
ATW
When there are any ON/OFF
functions related to the adjustment,
the names of the functions are
displayed on this line.
B
R
B
The adjustment parameters
for the selected item and their
adjustment values are
displayed.
0
0
You may adjust these items
using the corresponding
control knobs.
If you press a value area after
pressing [Clear], that
adjustment value is initialized
to standard.
Submenu
If the selected item has many parameters, a submenu is
displayed.
Example: when you select “Skin Detail” from the PAINT 2 initial display (Advance mode)
with the DXC-D50 series connected
Clear
2 / 5
Detail
Skin
Detail
Black
Gamma
WF/PIX
Select
Detail 1
Submenu
1
2
Level
H/V Ratio Frequency
0
0
0
Press to switch the parameters.
WF/PIX
Select
Detail 2
1
2
Crispening Level Dep
0
0
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Function menu displays
When you press and light the FUNCTION button of
the menu operation block, the scene file operation
menu display is obtained.
When “Operation” is selected
Example: with the DXC-D50 series connected
The ND filter number being selected
on the camera is displayed.
Filter
1
Opera-
tion
SW
Lens
/Pan
White
Black
Flare
Monitor
Select
Press one of these buttons
calls the adjustment display of
the corresponding paint item.
The items to be displayed on
this Function menu can be
changed using the OTHERS
menu. (You cannot jump to the
items that are not available on
the connected camera or
disabled.)
When you press this, the upper
half of the panel becomes the
monitor output setting display
(see the next page).
Gamma
/Knee
Detail
CLS
Skin
Detail
Matrix
Shutter
TLCS
Master
Gain
60 50.31
0dB
You may adjust these items using the
corresponding control knobs.
When “SW” is selected
Example: with the DXC-D35 series connected
Filter
1
Opera-
tion
SW
Lens
/Pan
Current page number /
total number of pages
1 / 2
Skin
Detail
Skin
Gate
Press either to flip the pages of
the menu.
ATW
TLCS
Auto
Knee
Skin
Matrix
Flare
Off
These buttons turn on and off the
corresponding functions.
Any button whose designation includes “Off”
turns the respective function OFF when you
light it. Other buttons turn the respective
functions ON when you light them.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Monitor output set display (Expansion menu)
When you press [Monitor Select] on an adjustment
display of the Paint menu, the upper half of the panel
becomes the monitor output setting display.
When the CCU-TX7 is connected, you
can select the WF/PIX output signals.
R/G/B: To independently select the R,
G, or B signal.
Monitor Select
R
G
B
RGB
SEQ
ENC
RGB: To select the R, G, and B signals
in combination.
Monitor
Select
SEQ: Only the WF output is enabled,
and you can monitor the waveforms of
the R, G, and B signals in sequence.
Press again to return to
the previous display.
ENC (encode): The encoded signal is
output.
Scene File operation menu display
When you press and light the SCENE button of the
menu operation block, the Scene File operation menu
display is obtained.
Scene Files
Scene file store button
Store
Scene file recall buttons:
Buttons 1 to 20 can be displayed
by pressing v or V, or turning the
leftmost (Page) control knob.
1
2
3
4
5
Scene 1 : STUDIO1
Scene 2 : DXC-D30
Scene 3 : TEST 002
Scene 4 :
Scene :
DXC_D
2*
Filename box:
File list
Enter a filename using the
second (Char) from the right and
the rightmost (Cur) control knob.
Scene 5 :
Page
Char
Cur
For details on the scene file operations, see page 53.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Menu Items with the DXC-D50-Series Cameras
z
The “Control items” marked with are those assigned
to the control knobs. The other items are operated on
the menu display.
The items displayed differ according to whether the
unit is in Advanced Setting mode or in Normal Setting
mode. The items shaded (
) in the table below are
displayed only in Advanced Setting mode.
Switching between Normal Setting mode and
Advanced Setting mode is performed in RCP Config
(Security → Status) on the OTHERS menu.
Paint menu (with the DXC-D50 series)
Paint menu consists of pages 1 to 5.
Paint 4 and 5 can also be selected in sequence by
pressing the PAINT 3 button.
You can select page 1 through 3 directly by pressing
the MENU buttons, PAINT 1, PAINT 2, or PAINT 3.
Pressing vor V of the page selected with a MENU
button flip pages 1 through 5 in sequence.
Page
Menu
Submenu
Control item
White Preset
Memory A
Function
Paint 1
White
To retrieve the white balance settings preset by the camera
To retrieve the white-balance settings stored in Memory A. The
retrieved settings can be adjusted in Auto or Manual mode (the
adjusted values are stored in Memory A).
Memory B
ATW
To retrieve the white-balance settings stored in Memory B. The
retrieved settings can be adjusted in Auto or Manual mode (the
adjusted values are stored in Memory B).
To turn ON/OFF the Auto Tracing White function (which
automatically adjusts the white balance when lighting conditions
change)
• R
• B
To adjust the gain of the R signal in the white when Memory A or
Memory B is pressed
To adjust the gain of the B signal in the white when Memory A or
Memory B is pressed
Black
Flare
• R
To adjust the gain of the R signal in the black
To adjust the gain of the B signal in the black
To adjust the master black
• B
• Master
Flare Off
To turn the flare (black level when flare is generated) correction
function ON/OFF
• R
To adjust the amount of flare correction for the R signal
To adjust the amount of flare correction for the G signal
To adjust the amount of flare correction for the B signal
To turn the Auto Knee circuit ON/OFF
• G
• B
Gamma/Knee
Auto Knee
• Gamma
• Blk Gamma
• Knee Point
To adjust the gamma level
To adjust the black gamma level
To adjust the level at which the knee correction starts. As the value
becomes larger, the start level decreases, which enhances the knee
correction effects.
• Knee Slope
To adjust the knee slope (amount of knee correction)
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Page
Menu
Submenu
Control item
• Level
Function
Paint 2
Detail
Detail 1
To adjust the detail (contour correction) level
• H/V Ratio
To adjust the ratio of V (Vertical) detail to H (Horizontal) detail in
detail correction. As the value becomes larger, the V detail ratio
increases.
• Frequency
• Crispening
• Level Dep
• CCS Level
Detail Gate
Skin DTL
To adjust the boost frequency (thickness of contour lines) for the
detail correction
Detail 2
To adjust the crispening level (appropriate level at which details of
noise signals are removed)
To adjust the level dependence (level at which the detail signal starts
being suppressed)
Cross Color
Skin Detail
To adjust the cross color suppress level to suppress the phenomenon
of color jittering or coloring when a minutely striped pattern is shot
To turn ON/OFF the skin gate area (target color range of skin detail
correction or skin matrix adjustment)
To turn the skin detail function (which suppresses the contour
correction in the selected area) ON/OFF
Auto Skin
The unit will go to Standby mode when this button is pressed, and
will automatically start obtaining the skin gate area data when Start
is pressed.
• Level
To adjust the amount of skin detail correction. As the value becomes
larger, the amount of detail in the skin gate area decreases.
• Phase
• Width
• Sat
To adjust the color phase of the designated area
To adjust the color width of the designated area
To adjust the color saturation of the designated area
To adjust the level of the black R gamma
To adjust the level of the black B gamma
To adjust the master black gamma
Black Gamma
Knee/DL
• R
• B
• Master
Auto Knee
• Point
Paint 3
To turn the auto knee ON/OFF
To adjust the level at which the knee correction starts. As the value
becomes larger, the start level decreases, which enhances the knee
correction effects.
• Slope
• R
To adjust the knee slope (amount of knee correction)
To adjust the level of the R gamma
Gamma
Matrix
• B
To adjust the level of the B gamma
• Master
• Hue
• Sat
To adjust the master gamma
Matrix 1
To adjust the hue of the linear matrix
To adjust the color saturation of the linear matrix
• Matrix
To select the Matrix Adjustment mode
STD: Standard
FL: For shooting under fluorescent light
High Sat: High saturation (increasing the saturation of primary
colors)
Matrix 2
Matrix 3
• R-G/• G-B/• B-R
To adjust the color tone for the R–G, G–B, or B–R elements of the
matrix
• Matrix
To select the Matrix Adjustment mode
• R-B/• G-R/• B-G
To adjust the color tone for the R–B, G–R, or B–G elements of the
matrix
• Matrix
Skin Matrix
• Hue
To select the Matrix Adjustment mode
Skin Matrix
To select the skin matrix function ON/OFF
To adjust the hue of the designated area
To adjust the color saturation of the designated area
• Sat
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Page
Menu
Submenu
Control item
Function
Paint 4
White Clip
• Master
To adjust the amount of white clip (the highest white level). As the
value becomes larger, the output level decreases.
TLCS
TLCS
To turn the TLCS (total level control) function ON/OFF
• AGC/C.Point
To set the f-stop value (f-2, f-2.8, f-4, or f-5.6) at which the iris
control is switched to AGC (auto gain control)
• AGC/Limit
• AE/C.Point
To set the upper limit value for the AGC (3 dB/6 dB/9 dB/12 dB/
18 dB) adjustment
To set the f-stop value (f-5.6, f-8, f-11, or f-16) at which the iris
control is switched to the AE (auto exposure)
• AE/Limit
STD
To set the upper limit value for AE control (100/150/200/250)
To select the standard auto iris mode
Auto Iris
Spot Light
Back Light
TLCS
To select the auto iris mode for shooting spot-lit subjects
To select the auto iris mode for shooting back-lit subjects
To turn the TLCS (total level control) function ON/OFF
To turn the shutter function ON/OFF
CLS/EVS
Shutter
CLS
To turn the CLS (clear scan) function (which reduces noise on the
horizontal scan lines when the monitor screen connected to a PC is
shot) ON/OFF
EVS
To turn the EVS mode (which reduces flicker by increasing the
vertical resolutions) ON/OFF
• Shutter
• CLS
To select the shutter speed
To adjust the CLS frequency
To adjust the low key saturation level
Paint 5
Low Key Sat
Auto Knee
• Level
Adaptive
To turn ON/OFF the function that makes the knee correction slope
smooth to make the gradation natural
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Function menu (with the DXC-D50 series)
Menu
Control item
Jump menu 1
Jump menu 2
Jump menu 3
Jump menu 4
Function
Operation
To jump to the adjustment screen designated for Menu 1 in Menu Set a)(Default: White of Paint 1)
To jump to the adjustment screen designated for Menu 2 in Menu Set a) (Default:Black of Paint 1)
To jump to the adjustment screen designated for Menu 3 in Menu Set a) (Default: Flare of Paint 1)
To jump to the adjustment screen designated for Menu 4 in Menu Set a) (Default: Gamma/Knee
of Paint 1)
Jump menu 5
Jump menu 6
To jump to the adjustment screen designated for Menu 5 in Menu Set a) (Default: Detail of Paint 2)
To jump to the adjustment screen designated for Menu 6 in Menu Set a) (Default: Skin Detail of
Paint 2)
Jump menu 7
To jump to the adjustment screen designated for Menu 7 in Menu Set a) (Default: Matrix of Paint
3)
Shutter
To turn the shutter function ON/OFF
• Shutter
CLS
To select the shutter speed
To turn the CLS (clear scan) function ON/OFF
To select the CLS frequency
• CLS
TLCS
To turn the TLCS (total level control) function ON/OFF
To select the master gain value among –3/0/3/6/9/12/18/24/30/36 dB
To turn the color temperature 5600K ON/OFF
To turn the skin detail function ON/OFF
• Master Gain
5600K
SW
Skin Detail
Detail Gate
To turn ON/OFF the display for the skin detail gate area (target color range for the skin detail
correction or the skin matrix adjustment)
ATW
To turn the ATW (auto tracing white balance) function (which automatically adjusts the white
balance when lighting conditions change) ON/OFF
TLCS
To turn the TLCS (total level control) function ON/OFF
To turn the Auto Knee function ON/OFF
To turn the skin matrix function ON/OFF
To turn the flare correction function ON/OFF (OFF while the button is lit)
To turn the option control function 1 ON/OFF
To turn the option control function 2 ON/OFF
To adjust the focus
Auto Knee
Skin Matrix
Flare Off
Option 1
Option 2
• Focus c)
• Zoom c)
• Pan d)
Lens/Pan b)
To adjust the zoom
To adjust panning of the tripod head
• Tilt d)
To adjust tilting of the tripod head
a) The submenu “Menu Set” can be selected from Security of RCP Config on the OTHERS menu.
b) The item “Lens/Pan” is displayed when Pan/Tilt Enable is set to ON with Security of RCP Config on the OTHERS menu.
c) To control the lens from this unit, the optional focus zoom servo unit and the interface unit for the camera adapter and lens are required.
d) To control the tripod head from this unit, an electric tripod head and the interface unit for the camera adapter and tripod head are required.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
OTHERS menu (with the DXC-D50 series)
Menu
2ndary menu Submenu
Control item
Function
Adjusting
White Shading
• R
To adjust the V white shading (vertical variation of the white) of the
R signal
• G
To adjust the V white shading of the G signal
To adjust the V white shading of the B signal
• B
Camera
Config
Camera ID
CAM ID IND
To turn the camera ID display ON/OFF while the camera is in Color
Bars mode
Clock IND
• Char
Switching of the clock indication
Cam: To always display the clock indication
Bars: To display only when the camera color bars are displayed
Off: No clock indication
To select characters when entering a camera ID (alphanumerics,
symbols, and space)
• Cur
To move the cursor when entering a camera ID (eight characters)
To register the entered camera ID
ID SET
Center Marker
Center Marker
Safety Zone
Screen Mode
Req
To turn the center marker ON/OFF
To set the safety zone (90%/80%/OFF)
To select the Screen mode (4:3/16:9)
Screen Mode a)
Diag
To request camera’s self-diagnostic data (available only when any
abnormality has been detected during self-diagnosis)
Reset
• Sel
To erase the camera’s self-diagnostic data
To display the data read from the camera in order (No display when
no abnormality has been detected during self-diagnosis)
Bars
Bars Type
To select the type of color-bar signals:
SMPTE(SPLIT)/SNG/FF 75%/FF 100%
File
Scene Trans
CAM->MS
MS->CAM
To transfer a scene file (from the camera to the Memory Stick)
To transfer a scene file (from the Memory Stick to the camera)
To copy the status of the master unit to slave units
To set the volume of the call buzzer
Copy to Slave
RCP Config RCP
Adjusting
Buzzer
• Call
Volume
• Touch
• Switch
To set the responding sound volume of the touch panel
To set the confirmation sound volume of the self-illuminating
switches
• Master
To set the total buzzer sound volume
Call Buzzer
Touch Click
SW Click
All Off
To turn the call buzzer ON/OFF
To turn the responding sound of the touch panel ON/OFF
To turn the confirmation sound of switches ON/OFF
To turn the volume of all the buzzers ON/OFF
To set the brightness of respective LEDs
LED Bright
• Switch
• Tally
• Other
• Master
To set the brightness of the all LEDs of the unit
RE Setting
VR Setting
BLACK/FLARE
To select the function for the BLACK/FLARE knob
Black: Black balance adjustment
Flare: Flare balance adjustment
VR STD Mode
To select the initial settings for IRIS or MASTER BLACK
adjustment mode: Absolute or Relative
VR Rel. Scale IRIS VR To select the response rate of the IRIS knob (relative-value
adjustment rates: 1/1, 1/2, and 1/4, where 1/1 is the quickest
response position)
a) The item “Screen Mode” is displayed when Screen Md Enable is set to ON with Security of RCP Config on the OTHERS menu.
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu
2ndary menu Submenu
Control item
Function
RCP Config VR Setting
(cont.)
M. Black VR
(Only available for RCP-D50) To select the response rate of the
MASTER BLACK knob (relative-value adjustment rates: 1/1, 1/2,
and 1/4, where 1/1 is the quickest response position)
(cont.)
Information
Cable Comp
SW Setting
To display the software version of the unit
Cable Length
To set the length of the remote cable (5 m/25 m/50 m)
• SW Assign/Sel
To allocate a function to the ASSIGN button
No Assign: No assignment
Black/Flare: Switching the function of the BLACK/FLARE knobs
Black Auto: ON/OFF of the auto black (Not operative)
ATW: ON/OFF of the auto tracing white balance
TLCS: ON/OFF of the total level control function
DynaLatitude: ON/OFF of the DynaLatitude function (Not operative)
CAM No.
CAM ID->No.
To switch the display of the camera number/tally indication of the
unit between camera ID and camera number
• No.
To select the camera number to be displayed on the RCP
Date adjustment of the clock built into the unit
Date/Time
Set
Date
• Year
• Month
• Day
Set
Cancel
• Hour
• Minute
• Second
Set
Time
Time adjustment of the clock built into the unit
Cancel
Gain
Comm Link
To turn ON/OFF command link operation (activation of several
cameras at the same time) of the gain
Shutter
To turn ON/OFF command link operation of shutter settings
R/B White
To turn ON/OFF command link operation of the white R/B
adjustment
R/B Black
To turn ON/OFF command link operation of the black R/B
adjustment
R/G/B Flare
Protocol Type a)
To turn ON/OFF command link operation of the flare R/G/B
adjustment
Comm Type
To set the connection mode
P Type 2: When connected to DXC-D35, DXC-D50, CCU-TX7,
CCU-D50, DSR-300/370/390/500/570
P Type 7: When connected to CCU-TX50
a) Be sure to power off the camera system and then power it on again after changing the “Protocol Type” setting.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Menu
2ndary menu Submenu
Control item
Function
RCP Config Security
(cont.)
Engineer Mode
To set whether to display “Status”, “Menu Set”, and “Code No.” or
not (With Engineer Mode ON, all operative menu items are
displayed regardless of the Advance Mode setting.)
Status a)
Advance Mode
To switch between the Normal Setting mode and Advanced Setting
mode of the menu
Screen Md Enable
Pan/Tilt Enable
Power On Active
To set whether switching between 4:3 and 16:9 is enabled or not
To set whether panning/tilting adjustment is enabled or not
To specify the Panel Active and Iris/Master Black Active statuses
when the unit is started up
Full Active: To set the unit to the Panel Active status when started up
IRIS/M.Black: To set the unit to the Iris/Master Black Active
status when started up
Lock: To set the unit to the Panel Lock status when started up
Keep state: To set the unit to the previous state when started up
Panel Active Lock
To set whether to use the Panel Active Lock function with a security
code or not.
Disable: Not to use the Panel Active Lock function
Enable: To use the Panel Active Lock function by specifying a
new security code
Enable (Engineer Code): To use the Panel Active Lock function
with the same security code as that for Engineer Mode
Code Change
To change the security code for Panel Active Lock (displayed only
when a security code for Panel Active Lock has been set)
Menu Set a)
Code No. a)
To select an item to be displayed on the function menu. Select the
number (1-7) using • Cur, and select the item with • Sel: White,
Black, Flare, Gamma/Knee, Detail, Cross Color, Skin Detail, Black
STR, Black Gamma, Knee/DL, Gamma, Matrix, Skin Matrix, White
Clip, TLCS, Auto Iris, CLS/EVS, Auto Knee, Low Key Sat, no jump
Code No.
To enable/disable the security code setting for Engineer Mode
Code Change
To change the security code for Engineer Mode (displayed only
when a security code for Engineer Mode has been set)
LCD
LCD Brightness/Contrast
• Bright
• Cont
To set the brightness of the LCD of the unit
To set the contrast of the LCD of the unit
LCD Moni. LCD Monitor
• Bright
To set the brightness of the LCD of the unit when displaying the
camera picture
Brightness/Contrast
• Cont
To set the contrast of the LCD of the unit when displaying the
camera picture
Memory Stick Memory Stick
Format
To perform formatting of the Memory Stick
a) The items “Status,” “Menu Set,” and “Code No.” are displayed only in Engineer Mode.
26
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Items with the DXC-D30/D35-Series Cameras
z
The “Control items” marked with are those assigned
to the control knobs. The other items are operated on
the menu display.
The items displayed differ according to whether the
unit is in Advanced Setting mode or in Normal Setting
mode. The items shaded (
) in the table below are
displayed only in Advanced Setting mode.
Switching between Normal Setting mode and
Advanced Setting mode is performed in RCP Config
(Security → Status) on the OTHERS menu.
Paint menu (with the DXC-D30/D35 series)
Paint menu consists of pages 1 to 4.
Paint 4 can also be selected by pressing the PAINT 3
button.
You can select page 1 through 3 directly by pressing
the MENU buttons, PAINT 1, PAINT 2, or PAINT 3.
Pressing vor V of the page selected with a MENU
button flip pages 1 through 4 in sequence.
Page
Menu
Submenu
Control item
White Preset
Auto
Function
Paint 1
White
To retrieve the preset white balance settings in the camera
To select the auto white balance adjustment mode
To select the manual white balance adjustment mode
Manual
ATW
To turn ON/OFF the Auto Tracing White function (which
automatically adjusts the white balance when lighting conditions
change)
• R
• B
To adjust the gain for the R signal in the white when Manual is
pressed
To adjust the gain for the B signal in the white when Manual is
pressed
Black
Auto
To select the auto black balance adjustment mode
To select the manual black balance adjustment mode
To adjust the gain of the R signal in the black
To adjust the gain of the B signal in the black
To adjust the master black
Manual
• R
• B
• Master
Flare Off
Flare
To turn the flare (black level when flare is generated) correction
function ON/OFF
• R
• G
• B
DL
To adjust the amount of flare correction for the R signal
To adjust the amount of flare correction for the G signal
To adjust the amount of flare correction for the B signal
Gamma/Knee
To turn ON/OFF the DynaLatitude function (for automatically
setting the contrast between the bright and dark areas by detecting
the levels of the subject in these areas)
Knee Preset
Auto Knee
• Gamma
To turn ON/OFF the mode that uses the preset knee correction value
To turn the Auto Knee circuit ON/OFF
To adjust the gamma level
• Knee Point
To adjust the level at which the knee correction starts. As the value
becomes larger, the start level decreases, which enhances the knee
correction effects.
• Knee Slope
To adjust the knee slope (amount of knee correction)
27
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Page
Menu
Submenu
Control item
• Level
Function
Paint 2
Detail
Detail 1
To adjust the detail (contour correction) level
• H/V Ratio
To adjust the ratio of V (vertical) detail to H (horizontal) detail in
detail correction. As the value becomes larger, the V detail ratio
increases.
• Frequency
To adjust the boost frequency (thickness of contour lines) for the
detail correction
• V-Limit
To adjust the limit value for vertical detail
Detail 2
• Crispening
To adjust the crispening level (appropriate level at which details of
noise signals are removed)
• Level Dep
• High L.
To adjust the level dependence (level at which the detail signal starts
being suppressed)
To adjust the amount of suppression of highlight detail (detail added
to a high-luminance area)
• AFT GAM
Aperture
To adjust the amount of detail added after gamma correction
To turn the aperture correction ON/OFF
Detail 3
Knee Apert
To turn ON/OFF the detail correction to the level higher than the
knee point
• Aperture
To adjust the amount of aperture correction
• Knee Apert
To adjust the amount of detail correction to the level higher than the
knee point
Cross Color
Skin Detail
Comb Filter R
Comb Filter G
• CCS Level
To turn the red comb filter in the detail circuit ON/OFF. If OFF is
selected, clarity improves, but cross color increases.
To turn the green comb filter in the detail circuit ON/OFF. If OFF is
selected, clarity improves, but cross color increases.
To adjust the cross color suppress level to suppress the phenomenon
of color jittering or coloring when a minutely striped pattern is shot
Skin Detail 1 Detail Gate
Skin DTL
To turn ON/OFF the skin gate area (target color range of skin detail
correction or skin matrix adjustment)
To turn the skin detail function (which suppresses the contour
correction in the selected area) ON/OFF
Auto Skin
The unit will go to Standby mode when this button is pressed, and
will automatically start obtaining the skin gate area data when Start
is pressed.
• Level
• Size
To adjust the amount of skin detail correction. As the value becomes
larger, the amount of detail in the skin gate area decreases.
To adjust the R–Y and B–Y ranges of the skin gate area (for setting
each range to the same value at the same time)
• R-Y
• B-Y
To adjust the R–Y range of the skin gate area
To adjust the B–Y range of the skin gate area
To turn the display of skin gate area ON/OFF
To turn the skin detail function ON/OFF
Skin Detail 2 Skin Gate
Skin DTL
Auto Skin
The unit will go to Standby mode when this button is pressed, and
will automatically start obtaining the skin gate area data when Start
is pressed.
• Level
• Posi
To adjust the skin detail level
To adjust the R–Y and B–Y position of the skin detail gate area (for
setting each range to the same value at the same time)
• R-Y
• B-Y
To adjust the R–Y position of the skin detail gate area
To adjust the B–Y position of the skin detail gate area
28
Download from Www.Somanuals.com. All Manuals Search And Download.
Page
Menu
Submenu
Black
Control item
Function
Paint 2
(cont.)
Black STR
• Level
To adjust the black stretch level
Stretch 1
• Stretch Level/Point 1 To adjust the upper limit of the signal levels that activate the black
stretch function
• Stretch Level/Point 2 To adjust the lower limit of the signal levels that activate the black
stretch function
Black
• Level
To adjust the black stretch level
Stretch 2
• Compress Level/
Point 1
To adjust the upper limit of the signal levels that activate the black
compress function
• Compress Level/
Point 2
To adjust the lower limit of the signal levels that activate the black
compress function
Paint 3
Knee/DL
DL
To turn ON/OFF the DynaLatitude function (for automatically
setting the contrast between the bright and dark areas by detecting
the levels of the subject in these areas)
Knee Preset
Auto Knee
• DL
To turn ON/OFF the mode that uses the preset knee correction value
To turn the Auto Knee function ON/OFF
To select the level of the DynaLatitude effects (Low/STD/High)
• Point
To adjust the level at which the knee correction starts. As the value
becomes larger, the start level decreases, which enhances the knee
correction effects.
• Slope
• Master
Init 3.5
To adjust the knee slope (amount of knee correction)
To adjust the master gamma
Gamma
To set the value of the initial part of the gamma curve for low
brightness to 3.5
Init 4.0
To set the value of the initial part of the gamma curve for low
brightness to 4.0
• R
To adjust the level of the R gamma
To adjust the level of the B gamma
To turn the matrix ON/OFF
• B
Matrix
Matrix 1
Matrix Off
• Hue
To adjust the hue of the linear matrix
To adjust the color saturation of the linear matrix
• Sat
Matrix 2
Matrix 3
• R-G/• G-B/• B-R
To adjust the color tone for the R–G, G–B, or B–R elements of the
matrix
• R-B/• G-R/• B-G
To adjust the color tone for the R–B, G–R, or B–G elements of the
matrix
Skin Matrix
Skin Matrix
• Hue
To select the skin matrix function ON/OFF
To adjust the hue of the designated area
• Sat
To adjust the color saturation of the designated area
Paint 4
White Clip
TLCS
• Master
To adjust the amount of white clip (the highest white level). As the
value becomes larger, the output level decreases.
TLCS
To turn the TLCS (total level control) function ON/OFF
• AGC/C.Point
To set the f-stop value (f-2, f-2.8, f-4, or f-5.6) at which the iris
control is switched to AGC (auto gain control)
• AGC/Limit
• AE/C.Point
To set the upper limit value for the AGC (3 dB/6 dB/9 dB/12 dB/18
dB) adjustment
To set the f-stop value (f-5.6, f-8, f-11, or f-16) at which the iris
control is switched to the AE (auto exposure)
Auto Iris
STD
To select the standard auto iris mode
Spot Light
Back Light
AI
To select the auto iris mode for shooting spot-lit subjects
To select the auto iris mode for shooting back-lit subjects
To select the intelligent auto iris mode a)
a) Only with models with the AI function
29
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Page
Menu
Submenu
Control item
TLCS
Function
Paint 4
(cont.)
CLS/EVS
To turn the TLCS (total level control) function ON/OFF
To turn the shutter function ON/OFF
Shutter
CLS
To turn the CLS (clear scan) function (which reduces noise on the
horizontal scan lines when the monitor screen connected to a PC is
shot) ON/OFF
EVS
To turn the EVS mode (which reduces flicker by increasing the
vertical resolutions) ON/OFF
• Shutter
• CLS
To select the shutter speed
To adjust the CLS frequency
Function menu (with the DXC-D30/D35 series)
Menu
Submenu Control item
Jump menu 1
Function
Operation
To jump to the adjustment screen designated for Menu 1 in Menu Set a)(Default: White of Paint 1)
To jump to the adjustment screen designated for Menu 2 in Menu Set a) (Default:Black of Paint 1)
To jump to the adjustment screen designated for Menu 3 in Menu Set a) (Default: Flare of Paint 1)
Jump menu 2
Jump menu 3
Jump menu 4
To jump to the adjustment screen designated for Menu 4 in Menu Set a) (Default: Gamma/Knee
of Paint 1)
Jump menu 5
Jump menu 6
To jump to the adjustment screen designated for Menu 5 in Menu Set a) (Default: Detail of Paint 2)
To jump to the adjustment screen designated for Menu 6 in Menu Set a) (Default: Skin Detail of
Paint 2)
Jump menu 7
To jump to the adjustment screen designated for Menu 7 in Menu Set a) (Default: Matrix of Paint
3)
Shutter
• Shutter
CLS
To turn the shutter function ON/OFF
To select the shutter speed
To turn the CLS (clear scan) function ON/OFF
To select the CLS frequency
• CLS
TLCS
To turn the TLCS (total level control) function ON/OFF
To select the master gain value among –3/0/3/6/9/12/18/18+DPR/24/24+DPR/HYPER Gain
To turn the skin detail function ON/OFF
• Master Gain
SW
Page1
Skin Detail
Detail Gate
To turn ON/OFF the display for the skin detail gate area (target color range for the skin detail
correction or the skin matrix adjustment)
ATW
To turn the ATW (auto tracing white balance) function (which automatically adjusts the white
balance when lighting conditions change) ON/OFF
TLCS
To turn the TLCS (total level control) function ON/OFF
To turn the Auto Knee function ON/OFF
Auto Knee
Skin Matrix
Flare Off
To turn the skin matrix function ON/OFF
To turn the flare correction function ON/OFF (OFF while the button is lit)
Page 2
Knee Aperture To turn ON/OFF the detail correction to the level higher than the knee point
Aperture
DL
To turn the aperture correction ON/OFF
To turn ON/OFF the DynaLatitude function (for automatically setting the contrast between the
bright and dark areas by detecting the levels of the subject in these areas)
White Clip Off To turn the white clip function ON/OFF (OFF while the button is lit)
Detail Off
Gamma Off
Matrix Off
To turn the detail adjustment function ON/OFF (OFF while the button is lit)
To turn the gamma adjustment function ON/OFF (OFF while the button is lit)
To turn the linear matrix adjustment function ON/OFF (OFF while the button is lit)
a) The submenu “Menu Set” can be selected from Security of RCP Config on the OTHERS menu.
30
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu
Lens/Pan a)
Submenu Control item
Option 1
Function
To turn the option control function 1 ON/OFF
To turn the option control function 2 ON/OFF
To adjust the focus
Option 2
• Focus b)
• Zoom b)
To adjust the zoom
• Pan c)
• Tilt c)
To adjust panning of the tripod head
To adjust tilting of the tripod head
a) The item “Lens/Pan” is displayed when Pan/Tilt Enable is set to ON with Security of RCP Config on the OTHERS menu.
b) To control the lens from this unit, the optional focus zoom servo unit and the interface unit for the camera adapter and lens are required.
c) To control the tripod head from this unit, an electric tripod head and the interface unit for the camera adapter and tripod head are required.
OTHERS menu (with the DXC-D30/D35 series)
Menu
2ndary menu Submenu
Control item
Function
Adjusting
White Shading
• R
To adjust the V white shading (vertical variation of the white) of the
R signal
• G
To adjust the V white shading of the G signal
To adjust the V white shading of the B signal
• B
Camera
Config
Camera ID
CAM ID IND
To turn the camera ID display ON/OFF while the camera is in Color
Bars mode
Clock IND
• Char
Switching of the clock indication
Cam: To always display the clock indication
Bars: To display only when the camera color bars are displayed
Off: No clock indication
To select characters when entering a camera ID (alphanumerics,
symbols, and space)
• Cur
To move the cursor when entering a camera ID (eight characters)
To register the entered camera ID
ID SET
Center Marker
Center Marker
Safety Zone
Screen Mode
Req
To turn the center marker ON/OFF
To set the safety zone (90%/80%/OFF)
To select the Screen mode (4:3/16:9)
Screen Mode a)
Diag
To request camera’s self-diagnostic data (available only when any
abnormality has been detected during self-diagnosis)
Reset
• Sel
To erase the camera’s self-diagnostic data
To display the data read from the camera in order (No display when
no abnormality has been detected during self-diagnosis)
Bars
Bars Type
To select the type of color-bar signals:
SMPTE (SPLIT)/SNG/FF 75%/FF 100%
File
Setup File
To store/retrieve a setup file
Copy to Slave
To copy the scene files to slave units
To set the volume of the call buzzer
To set the responding sound volume of the touch panel
RCP Config RCP
Adjusting
Buzzer
Volume
• Call
• Touch
• Switch
To set the confirmation sound volume of the self-illuminating
switches
• Master
To set the total buzzer sound volume
Call Buzzer
Touch Click
SW Click
All Off
To turn the call buzzer ON/OFF
To turn the responding sound of the touch panel ON/OFF
To turn the confirmation sound of switches ON/OFF
To turn the volume of all the buzzers ON/OFF
a) The item “Screen Mode” is displayed when Screen Md Enable is set to ON with Security of RCP Config on the OTHERS menu.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Menu
2ndary menu Submenu
Control item
• Switch
Function
RCP Config RCP
(cont.) Adjusting
LED Bright
To set the brightness of respective LEDs
• Tally
(cont.)
• Other
• Master
To set the brightness of the all LEDs of the unit
RE Setting
BLACK/FLARE
To select the function for the BLACK/FLARE knob
Black: Black balance adjustment
Flare: Flare balance adjustment
VR Setting
VR STD Mode
To select the initial settings for IRIS or MASTER BLACK
Adjustment mode: Absolute or Relative
VR Rel. Scale IRIS VR To select the response rate of the IRIS knob (relative-value
adjustment rates: 1/1, 1/2, and 1/4, where 1/1 is the quickest
response position)
M. Black VR
(Only available for RCP-D50) To select the response rate of the
MASTER BLACK knob (relative-value adjustment rates: 1/1, 1/2,
and 1/4, where 1/1 is the quickest response position)
Information
Cable Comp
SW Setting
To display the software version of the unit
Cable Length
To set the length of the remote cable (5 m/25 m/50 m)
• SW Assign/Sel
To allocate a function to the ASSIGN button
No Assign: No assignment
Black/Flare: Switching the function of the BLACK/FLARE knobs
Black Auto: ON/OFF of the auto black
ATW: ON/OFF of the auto tracing white balance
TLCS: ON/OFF of the total level control function
DynaLatitude: ON/OFF of the DynaLatitude function
CAM No.
CAM ID->No.
To switch the display of the camera number/tally indication of the
unit between camera ID and camera number
• No.
To select the camera number to be displayed on the RCP
Date adjustment of the clock built into the unit
Date/Time
Set
Date
• Year
• Month
• Day
Set
Cancel
• Hour
• Minute
• Second
Set
Time
Time adjustment of the clock built into the unit
Cancel
Gain
Comm Link
To turn ON/OFF command link operation (activation of several
cameras at the same time) of the gain
Shutter
To turn ON/OFF command link operation of shutter settings
R/B White
To turn ON/OFF command link operation of the white R/B
adjustment
R/B Black
To turn ON/OFF command link operation of the black R/B
adjustment
R/G/B Flare
Protocol Type a)
To turn ON/OFF command link operation of the flare R/G/B
adjustment
Comm Type
To set the connection mode
P Type 2: When connected to DXC-D35, DXC-D50, CCU-TX7,
CCU-D50, DSR-300/370/390/500/570
P Type 7: When connected to CCU-TX50
a) Be sure to power off the camera system and then power it on again after changing the “Protocol Type” setting.
32
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu
2ndary menu Submenu
Control item
Function
RCP Config Security
(cont.)
Engineer Mode
To set whether to display “Status”, “Menu Set”, and “Code No.” or
not (With Engineer Mode ON, all operative menu items are
displayed regardless of the Advance Mode setting.)
Status a)
Advance Mode
To switch between the Normal Setting mode and Advanced Setting
mode of the menu
Screen Md Enable
Pan/Tilt Enable
Power On Active
To set whether switching between 4:3 and 16:9 is enabled or not
To set whether panning/tilting adjustment is enabled or not
To specify the Panel Active and Iris/Master Black Active statuses
when the unit is started up
Full Active: To set the unit to the Panel Active status when started up
IRIS/M.Black: To set the unit to the Iris/Master Black Active
status when started up
Lock: To set the unit to the Panel Lock status when started up
Keep state: To set the unit to the previous state when started up
Panel Active Lock
To set whether to use the Panel Active Lock function with a security
code or not.
Disable: Not to use the Panel Active Lock function
Enable: To use the Panel Active Lock function by specifying a
new security code
Enable (Engineer Code): To use the Panel Active Lock function
with the same security code as that for Engineer Mode
Code Change
To change the security code for Panel Active Lock (displayed only
when a security code for Panel Active Lock has been set)
Menu Set a)
Code No. a)
To select an item to be displayed on the function menu. Select the
number (1-7) using • Cur, and select the item with • Sel: White,
Black, Flare, Gamma/Knee, Detail, Cross Color, Skin Detail, Black
STR, Black Gamma, Knee/DL, Gamma, Matrix, Skin Matrix, White
Clip, TLCS, Auto Iris, CLS/EVS, Auto Knee, Low Key Sat, no jump
Code No.
To enable/disable the security code setting for Engineer Mode
Code Change
To change the security code for Engineer Mode (displayed only
when a security code for Engineer Mode has been set)
LCD
LCD Brightness/Contrast
• Bright
• Cont
To set the brightness of the LCD of the unit
To set the contrast of the LCD of the unit
LCD Moni. LCD Monitor
• Bright
To set the brightness of the LCD of the unit when displaying the
camera picture
Brightness/Contrast
• Cont
To set the contrast of the LCD of the unit when displaying the
camera picture
Memory Stick Memory Stick
Format
To perform formatting of the Memory Stick
a) The items “Status,” “Menu Set,” and “Code No.” are displayed only in Engineer Mode.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Menu Items with the DXC-637-Series Cameras
z
The “Control items” marked with are those assigned
to the control knobs. The other items are operated on
the menu display.
The items displayed differ according to whether the
unit is in Advanced Setting mode or in Normal Setting
mode. The items shaded (
) in the table below are
To operate the DXC-637-series cameras from this unit,
it is necessary to connect the camera and this unit via
the CCU-TX7.
displayed only in Advanced Setting mode.
Switching between Normal Setting mode and
Advanced Setting mode is performed in RCP Config
(Security → Status) on the OTHERS menu.
Paint menu (with the DXC-637 series)
Paint menu consists of pages 1 to 3.
Page
Menu
Control item
White Preset
Auto
Function
Paint 1
White
To retrieve the preset white balance settings in the camera
To select the auto white balance adjustment mode a)
To select the manual white balance adjustment mode a)
Manual
ATW
To turn ON/OFF the Auto Tracing White function (which
automatically adjusts the white balance when lighting conditions
change)
• R
• B
To adjust the gain for the R signal in the white when Manual is
pressed
To adjust the gain for the B signal in the white when Manual is
pressed
Black
Auto
To select the auto black balance adjustment mode a)
To select the manual black balance adjustment mode a)
To adjust the gain of the R signal in the black
To adjust the gain of the B signal in the black
To adjust the master black
Manual
• R
• B
• Master
Knee Preset
Auto Knee
• Knee Point
Gamma/Knee
To turn ON/OFF the mode that uses the preset knee correction value
To turn the Auto Knee circuit ON/OFF
To adjust the level at which the knee correction starts. As the value
becomes larger, the start level decreases, which enhances the knee
correction effects.
Paint 2
Paint 3
Detail
• Level
To adjust the detail (contour correction) level
Knee/DL
Knee Preset
Auto Knee
• Point
To turn ON/OFF the mode that uses the preset knee correction value
To turn the Auto Knee function ON/OFF
To adjust the level at which the knee correction starts. As the value
becomes larger, the start level decreases, which enhances the knee
correction effects.
Matrix
• Matrix
To select the Matrix Adjustment mode
STD: Standard
FL: For shooting under fluorescent light
High Sat: High saturation (increasing the saturation of primary
colors)
a) The Auto/Manual setting for Black is synchronized with that for White.
34
Download from Www.Somanuals.com. All Manuals Search And Download.
Function menu (with the DXC-637 series)
Menu
Control item
Jump menu 1
Jump menu 2
Jump menu 3
Jump menu 4
Function
Operation
To jump to the adjustment screen designated for Menu 1 in Menu Set a)(Default: White of Paint 1)
To jump to the adjustment screen designated for Menu 2 in Menu Set a) (Default:Black of Paint 1)
To jump to the adjustment screen designated for Menu 3 in Menu Set a) (Default: Flare of Paint 1)
To jump to the adjustment screen designated for Menu 4 in Menu Set a) (Default: Gamma/Knee
of Paint 1)
Jump menu 5
Jump menu 6
To jump to the adjustment screen designated for Menu 5 in Menu Set a) (Default: Detail of Paint 2)
To jump to the adjustment screen designated for Menu 6 in Menu Set a) (Default: Skin Detail of
Paint 2)
Jump menu 7
To jump to the adjustment screen designated for Menu 7 in Menu Set a) (Default: Matrix of Paint
3)
Shutter
• Shutter
CLS
To turn the shutter function ON/OFF
To select the shutter speed
To turn the CLS (clear scan) function ON/OFF
To select the CLS frequency
• CLS
• Master Gain
ATW
To select the master gain setting from among Hi/Mid/Low
SW
To turn the ATW (auto tracing white balance) function (which automatically adjusts the white
balance when lighting conditions change) ON/OFF
Auto Knee
Option 1
Option 2
• Focus c)
• Zoom c)
• Pan d)
To turn the Auto Knee function ON/OFF
To turn the option control function 1 ON/OFF
To turn the option control function 2 ON/OFF
To adjust the focus
Lens/Pan b)
To adjust the zoom
To adjust panning of the tripod head
To adjust tilting of the tripod head
• Tilt d)
a) The submenu “Menu Set” can be selected from Security of RCP Config on the OTHERS menu.
b) The item “Lens/Pan” is displayed when Pan/Tilt Enable is set to ON with Security of RCP Config on the OTHERS menu.
c) To control the lens from this unit, the optional focus zoom servo unit and the interface unit for the camera adapter and lens are required.
d) To control the tripod head from this unit, an electric tripod head and the interface unit for the camera adapter and tripod head are required.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
OTHERS menu (with the DXC-637 series)
Menu
2ndary menu Submenu
Control item
Function
Camera
Config
Title ID
Title IND
To turn the title display ON/OFF while the camera is in Color Bars
mode
Clock IND
Switching of the clock indication
Cam: To always display the clock indication
Off: No clock indication
File
Copy to Slave
To copy the status of the master unit to slave units
To set the volume of the call buzzer
RCP Config RCP
Adjusting
Buzzer
• Call
Volume
• Touch
• Switch
To set the responding sound volume of the touch panel
To set the confirmation sound volume of the self-illuminating
switches
• Master
To set the total buzzer sound volume
Call Buzzer
Touch Click
SW Click
All Off
To turn the call buzzer ON/OFF
To turn the responding sound of the touch panel ON/OFF
To turn the confirmation sound of switches ON/OFF
To turn the volume of all the buzzers ON/OFF
To set the brightness of respective LEDs
LED Bright
• Switch
• Tally
• Other
• Master
To set the brightness of the all LEDs of the unit
VR Setting
VR STD Mode
To select the initial settings for IRIS or MASTER BLACK
Adjustment mode: Absolute or Relative
VR Rel. Scale IRIS VR To select the response rate of the IRIS knob (relative-value
adjustment rates: 1/1, 1/2, and 1/4, where 1/1 is the quickest
response position)
M. Black VR
(Only available for RCP-D50) To select the response rate of the
MASTER BLACK knob (relative-value adjustment rates: 1/1, 1/2,
and 1/4, where 1/1 is the quickest response position)
Information
Cable Comp
SW Setting
To display the software version of the unit
Cable Length
To set the length of the remote cable (5 m/25 m/50 m)
• SW Assign/Sel
To allocate a function to the ASSIGN button
No Assign: No assignment
Black/Flare: Switching the function of the BLACK/FLARE knobs
Black Auto: ON/OFF of the auto black (not operative)
ATW: ON/OFF of the auto tracing white balance
TLCS: ON/OFF of the total level control function (not operative)
DynaLatitude: ON/OFF of the DynaLatitude function (not operative)
CAM No.
• No.
To select the camera number to be displayed on the RCP
Date adjustment of the clock built into the unit
Date/Time Set Date
• Year
• Month
• Day
Set
Cancel
• Hour
• Minute
• Second
Set
Time
Time adjustment of the clock built into the unit
Cancel
36
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu
2ndary menu Submenu
Control item
Function
RCP Config Comm Link
(cont.)
Gain
To turn ON/OFF command link operation (activation of several
cameras at the same time) of the gain
Shutter
To turn ON/OFF command link operation of shutter settings
R/B White
To turn ON/OFF command link operation of the white R/B
adjustment
R/B Black
To turn ON/OFF command link operation of the black R/B
adjustment
R/G/B Flare
Protocol Type a)
To turn ON/OFF command link operation of the flare R/G/B
adjustment
Comm Type
Security
To set the connection mode
P Type 2: When connected to DXC-D35, DXC-D50, CCU-TX7,
CCU-D50, DSR-300/370/390/500/570
P Type 7: When connected to CCU-TX50
Engineer Mode
Status b)
To set whether to display “Status”, “Menu Set”, and “Code No.” or
not (With Engineer Mode ON, all operative menu items are
displayed regardless of the Advance Mode setting.)
Advance Mode
To switch between the Normal Setting mode and Advanced Setting
mode of the menu
Screen Md Enable
Pan/Tilt Enable
Power On Active
To set whether switching between 4:3 and 16:9 is enabled or not
To set whether panning/tilting adjustment is enabled or not
To specify the Panel Active and Iris/Master Black Active statuses
when the unit is started up
Full Active: To set the unit to the Panel Active status when started up
IRIS/M.Black: To set the unit to the Iris/Master Black Active
status when started up
Lock: To set the unit to the Panel Lock status when started up
Keep state: To set the unit to the previous state when started up
Panel Active Lock
To set whether to use the Panel Active Lock function with a security
code or not.
Disable: Not to use the Panel Active Lock function
Enable: To use the Panel Active Lock function by specifying a
new security code
Enable (Engineer Code): To use the Panel Active Lock function
with the same security code as that for Engineer Mode
Code Change
To change the security code for Panel Active Lock (displayed only
when a security code for Panel Active Lock has been set)
Menu Set b)
Code No. b)
To select an item to be displayed on the function menu. Select the
number (1-7) using • Cur, and select the item with • Sel: White,
Black, Flare, Gamma/Knee, Detail, Cross Color, Skin Detail, Black
STR, Black Gamma, Knee/DL, Gamma, Matrix, Skin Matrix, White
Clip, TLCS, Auto Iris, CLS/EVS, Auto Knee, Low Key Sat, no jump
Code No.
To enable/disable the security code setting for Engineer Mode
Code Change
To change the security code for Engineer Mode (displayed only
when a security code for Engineer Mode has been set)
LCD
LCD Brightness/Contrast
• Bright
• Cont
To set the brightness of the LCD of the unit
To set the contrast of the LCD of the unit
LCD Moni. LCD Monitor
• Bright
To set the brightness of the LCD of the unit when displaying the
camera picture
Brightness/Contrast
• Cont
To set the contrast of the LCD of the unit when displaying the
camera picture
Memory Stick Memory Stick
Format
To perform formatting of the Memory Stick
a) Be sure to power off the camera system and then power it on again after changing the “Protocol Type” setting.
b) The items “Status,” “Menu Set,” and “Code No.” are displayed only in Engineer Mode.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Menu Items with the CCU-TX50
z
The “Control items” marked with are those assigned
to the control knobs. The other items are operated on
the menu display.
The items displayed differ according to whether the
unit is in Advanced Setting mode or in Normal Setting
mode. The items shaded (
) in the table below are
displayed only in Advanced Setting mode.
Switching between Normal Setting mode and
Advanced Setting mode is performed in RCP Config
(Security → Status) on the OTHERS menu.
Paint menu (with the CCU-TX50)
Paint menu consists of pages 1 to 5.
Paint 4 and 5 can also be selected in sequence by
pressing the PAINT 3 button.
You can select page 1 through 3 directly by pressing
the MENU buttons, PAINT 1, PAINT 2, or PAINT 3.
Pressing vor V of the page selected with a MENU
button flip pages 1 through 5 in sequence.
Page
Menu
Submenu
Control item
White Preset
Memory A
Function
Paint 1
White
To retrieve the white balance settings preset by the camera
To retrieve the white-balance settings stored in Memory A. The
retrieved settings can be adjusted in Auto or Manual mode (the
adjusted values are stored in Memory A).
Memory B
ATW
To retrieve the white-balance settings stored in Memory B. The
retrieved settings can be adjusted in Auto or Manual mode (the
adjusted values are stored in Memory B).
To turn ON/OFF the Auto Tracing White function (which
automatically adjusts the white balance when lighting conditions
change)
• R
• B
To adjust the gain of the R signal in the white when Memory A or
Memory B is pressed
To adjust the gain of the B signal in the white when Memory A or
Memory B is pressed
Black
Flare
• R
To adjust the gain of the R signal in the black
To adjust the gain of the B signal in the black
To adjust the master black
• B
• Master
Flare Off
To turn the flare (black level when flare is generated) correction
function ON/OFF
• R
To adjust the amount of flare correction for the R signal
To adjust the amount of flare correction for the G signal
To adjust the amount of flare correction for the B signal
To turn the Auto Knee circuit ON/OFF
• G
• B
Gamma/Knee
Auto Knee
• Gamma
• Blk Gamma
• Knee Point
To adjust the gamma level
To adjust the black gamma level
To adjust the level at which the knee correction starts. As the value
becomes larger, the start level decreases, which enhances the knee
correction effects.
• Knee Slope
To adjust the knee slope (amount of knee correction)
38
Download from Www.Somanuals.com. All Manuals Search And Download.
Page
Menu
Submenu
Control item
• Level
Function
Paint 2
Detail
Detail 1
To adjust the detail (contour correction) level
• H/V Ratio
To adjust the ratio of V (Vertical) detail to H (Horizontal) detail in
detail correction. As the value becomes larger, the V detail ratio
increases.
• Frequency
• Crispening
• Level Dep
• CCS Level
Detail Gate
Skin DTL
To adjust the boost frequency (thickness of contour lines) for the
detail correction
Detail 2
To adjust the crispening level (appropriate level at which details of
noise signals are removed)
To adjust the level dependence (level at which the detail signal starts
being suppressed)
Cross Color
Skin Detail
To adjust the cross color suppress level to suppress the phenomenon
of color jittering or coloring when a minutely striped pattern is shot
To turn ON/OFF the skin gate area (target color range of skin detail
correction or skin matrix adjustment)
To turn the skin detail function (which suppresses the contour
correction in the selected area) ON/OFF
Auto Skin
The unit will go to Standby mode when this button is pressed, and
will automatically start obtaining the skin gate area data when Start
is pressed.
• Level
To adjust the amount of skin detail correction. As the value becomes
larger, the amount of detail in the skin gate area decreases.
• Phase
• Width
• Sat
To adjust the color phase of the designated area
To adjust the color width of the designated area
To adjust the color saturation of the designated area
To adjust the level of the black R gamma
To adjust the level of the black B gamma
To adjust the master black gamma
Black Gamma
Knee/DL
• R
• B
• Master
Auto Knee
• Point
Paint 3
To turn the auto knee ON/OFF
To adjust the level at which the knee correction starts. As the value
becomes larger, the start level decreases, which enhances the knee
correction effects.
• Slope
• R
To adjust the knee slope (amount of knee correction)
To adjust the level of the R gamma
Gamma
Matrix
• B
To adjust the level of the B gamma
• Master
• Hue
• Sat
To adjust the master gamma
Matrix 1
To adjust the hue of the linear matrix
To adjust the color saturation of the linear matrix
• Matrix
To select the Matrix Adjustment mode
STD: Standard
FL: For shooting under fluorescent light
High Sat: High saturation (increasing the saturation of primary
colors)
Matrix 2
Matrix 3
• R-G/• G-B/• B-R
To adjust the color tone for the R–G, G–B, or B–R elements of the
matrix
• Matrix
To select the Matrix Adjustment mode
• R-B/• G-R/• B-G
To adjust the color tone for the R–B, G–R, or B–G elements of the
matrix
• Matrix
Skin Matrix
• Hue
To select the Matrix Adjustment mode
Skin Matrix
To select the skin matrix function ON/OFF
To adjust the hue of the designated area
To adjust the color saturation of the designated area
• Sat
39
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Page
Menu
Submenu
Control item
Function
Paint 4
White Clip
• Master
To adjust the amount of white clip (the highest white level). As the
value becomes larger, the output level decreases.
TLCS
TLCS
To turn the TLCS (total level control) function ON/OFF
• AGC/C.Point
To set the f-stop value (f-2, f-2.8, f-4, or f-5.6) at which the iris
control is switched to AGC (auto gain control)
• AGC/Limit
• AE/C.Point
To set the upper limit value for the AGC (3 dB/6 dB/9 dB/12 dB/
18 dB) adjustment
To set the f-stop value (f-5.6, f-8, f-11, or f-16) at which the iris
control is switched to the AE (auto exposure)
• AE/Limit
STD
To set the upper limit value for AE control (100/150/200/250)
To select the standard auto iris mode
Auto Iris
Spot Light
Back Light
TLCS
To select the auto iris mode for shooting spot-lit subjects
To select the auto iris mode for shooting back-lit subjects
To turn the TLCS (total level control) function ON/OFF
To turn the shutter function ON/OFF
CLS/EVS
Shutter
CLS
To turn the CLS (clear scan) function (which reduces noise on the
horizontal scan lines when the monitor screen connected to a PC is
shot) ON/OFF
EVS
To turn the EVS mode (which reduces flicker by increasing the
vertical resolutions) ON/OFF
• Shutter
• CLS
To select the shutter speed
To adjust the CLS frequency
To adjust the low key saturation level
Paint 5
Low Key Sat
Auto Knee
• Level
Adaptive
To turn ON/OFF the function that makes the knee correction slope
smooth to make the gradation natural
40
Download from Www.Somanuals.com. All Manuals Search And Download.
Function menu (with the CCU-TX50)
Menu
Control item
Jump menu 1
Jump menu 2
Jump menu 3
Jump menu 4
Function
Operation
To jump to the adjustment screen designated for Menu 1 in Menu Set a)(Default: White of Paint 1)
To jump to the adjustment screen designated for Menu 2 in Menu Set a) (Default:Black of Paint 1)
To jump to the adjustment screen designated for Menu 3 in Menu Set a) (Default: Flare of Paint 1)
To jump to the adjustment screen designated for Menu 4 in Menu Set a) (Default: Gamma/Knee
of Paint 1)
Jump menu 5
Jump menu 6
To jump to the adjustment screen designated for Menu 5 in Menu Set a) (Default: Detail of Paint 2)
To jump to the adjustment screen designated for Menu 6 in Menu Set a) (Default: Skin Detail of
Paint 2)
Jump menu 7
To jump to the adjustment screen designated for Menu 7 in Menu Set a) (Default: Matrix of Paint
3)
Shutter
To turn the shutter function ON/OFF
• Shutter
CLS
To select the shutter speed
To turn the CLS (clear scan) function ON/OFF
To select the CLS frequency
• CLS
TLCS
To turn the TLCS (total level control) function ON/OFF
To select the master gain value among –3/0/3/6/9/12/18/24/30/36 dB
To turn the color temperature 5600K ON/OFF
To turn the skin detail function ON/OFF
• Master Gain
5600K
SW
Skin Detail
Detail Gate
To turn ON/OFF the display for the skin detail gate area (target color range for the skin detail
correction or the skin matrix adjustment)
ATW
To turn the ATW (auto tracing white balance) function (which automatically adjusts the white
balance when lighting conditions change) ON/OFF
TLCS
To turn the TLCS (total level control) function ON/OFF
To turn the Auto Knee function ON/OFF
To turn the skin matrix function ON/OFF
To turn the flare correction function ON/OFF (OFF while the button is lit)
To turn the option control function 1 ON/OFF
To turn the option control function 2 ON/OFF
To adjust the focus
Auto Knee
Skin Matrix
Flare Off
Option 1
Option 2
• Focus c)
• Zoom c)
• Pan d)
Lens/Pan b)
To adjust the zoom
To adjust panning of the tripod head
• Tilt d)
To adjust tilting of the tripod head
a) The submenu “Menu Set” can be selected from Security of RCP Config on the OTHERS menu.
b)The item “Lens/Pan” is displayed when Pan/Tilt Enable is set to ON with Security of RCP Config on the OTHERS menu.
c) To control the lens from this unit, the optional focus zoom servo unit and the interface unit for the camera adapter and lens are required.
In addition, special settings must be made on the connected CA-TX50. For details, consult your Sony dealer.
d)To control the tripod head from this unit, an electric tripod head and the interface unit for the camera adapter and tripod head are required.
In addition, special settings must be made on the connected CA-TX50. For details, consult your Sony dealer.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
OTHERS menu (with the CCU-TX50)
Menu
2ndary menu Submenu
Control item
Function
Adjusting
White Shading
• R
To adjust the V white shading (vertical variation of the white) of the
R signal
• G
To adjust the V white shading of the G signal
To adjust the V white shading of the B signal
To select the Screen mode (4:3/16:9)
• B
Camera
Config
Screen Mode a)
Scene Trans
Screen Mode
File
CAM->MS
MS->CAM
• Call
To transfer a scene file (from the camera to the Memory Stick)
To transfer a scene file (from the Memory Stick to the camera)
To set the volume of the call buzzer
RCP Config RCP
Adjusting
Buzzer
Volume
• Touch
To set the responding sound volume of the touch panel
• Switch
To set the confirmation sound volume of the self-illuminating
switches
• Master
To set the total buzzer sound volume
Call Buzzer
Touch Click
SW Click
All Off
To turn the call buzzer ON/OFF
To turn the responding sound of the touch panel ON/OFF
To turn the confirmation sound of switches ON/OFF
To turn the volume of all the buzzers ON/OFF
To set the brightness of respective LEDs
LED Bright
• Switch
• Tally
• Other
• Master
To set the brightness of the all LEDs of the unit
RE Setting
VR Setting
BLACK/FLARE
To select the function for the BLACK/FLARE knob
Black: Black balance adjustment
Flare: Flare balance adjustment
VR STD Mode
To select the initial settings for IRIS or MASTER BLACK
adjustment mode: Absolute or Relative
VR Rel. Scale IRIS VR To select the response rate of the IRIS knob (relative-value
adjustment rates: 1/1, 1/2, and 1/4, where 1/1 is the quickest
response position)
M. Black VR
(Only available for RCP-D50) To select the response rate of the
MASTER BLACK knob (relative-value adjustment rates: 1/1, 1/2,
and 1/4, where 1/1 is the quickest response position)
Information
Cable Comp
SW Setting
To display the software version of the unit
Cable Length
To set the length of the remote cable (5 m/25 m/50 m)
• SW Assign/Sel
To allocate a function to the ASSIGN button
No Assign: No assignment
Black/Flare: Switching the function of the BLACK/FLARE knobs
Black Auto: ON/OFF of the auto black (Not operative)
ATW: ON/OFF of the auto tracing white balance
TLCS: ON/OFF of the total level control function
DynaLatitude: ON/OFF of the DynaLatitude function (Not operative)
CCU character: Switching the CCU-TX50 character pages
CAM No.
CAM ID->No.
• No.
To switch the display of the camera number/tally indication of the
unit between camera ID and camera number b)
To select the camera number to be displayed on the RCP
a) The item “Screen Mode” is displayed when Screen Md Enable is set to ON with Security of RCP Config on the OTHERS menu.
b) Camera ID cannot be displayed when connected to the CCU-TX50.
42
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu
2ndary menu Submenu
Control item
• Year
Function
RCP Config Date/Time
Date
Date adjustment of the clock built into the unit
(cont.)
Set
• Month
• Day
Set
Cancel
Time
• Hour
Time adjustment of the clock built into the unit
• Minute
• Second
Set
Cancel
Comm Type
Security
Protocol Type a)
To set the connection mode
P Type 2: When connected to DXC-D35, DXC-D50, CCU-TX7,
CCU-D50, DSR-300/370/390/500/570
P Type 7: When connected to CCU-TX50
Engineer Mode
Status b)
To set whether to display “Status”, “Menu Set”, and “Code No.” or
not (With Engineer Mode ON, all operative menu items are
displayed regardless of the Advance Mode setting.)
Advance Mode
To switch between the Normal Setting mode and Advanced Setting
mode of the menu
Screen Md Enable
Pan/Tilt Enable
Power On Active
To set whether switching between 4:3 and 16:9 is enabled or not
To set whether panning/tilting adjustment is enabled or not
To specify the Panel Active and Iris/Master Black Active statuses
when the unit is started up
Full Active: To set the unit to the Panel Active status when started up
IRIS/M.Black: To set the unit to the Iris/Master Black Active
status when started up
Lock: To set the unit to the Panel Lock status when started up
Keep state: To set the unit to the previous state when started up
Panel Active Lock
To set whether to use the Panel Active Lock function with a security
code or not.
Disable: Not to use the Panel Active Lock function
Enable: To use the Panel Active Lock function by specifying a
new security code
Enable (Engineer Code): To use the Panel Active Lock function
with the same security code as that for Engineer Mode
Code Change
To change the security code for Panel Active Lock (displayed only
when a security code for Panel Active Lock has been set)
Menu Set b)
Code No. b)
To select an item to be displayed on the function menu. Select the
number (1-7) using • Cur, and select the item with • Sel: White,
Black, Flare, Gamma/Knee, Detail, Cross Color, Skin Detail, Black
STR, Black Gamma, Knee/DL, Gamma, Matrix, Skin Matrix, White
Clip, TLCS, Auto Iris, CLS/EVS, Auto Knee, Low Key Sat, no jump
Code No.
To enable/disable the security code setting for Engineer Mode
Code Change
To change the security code for Engineer Mode (displayed only
when a security code for Engineer Mode has been set)
a) Be sure to power off the camera system and then power it on again after changing the “Protocol Type” setting.
b) The items “Status,” “Menu Set,” and “Code No.” are displayed only in Engineer Mode.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Configuration and Basic Menu Operations
Menu
2ndary menu Submenu
Control item
• Bright
Function
LCD
(cont.)
LCD Brightness/Contrast
To set the brightness of the LCD of the unit
To set the contrast of the LCD of the unit
• Cont
LCD Moni. LCD Monitor
Brightness/Contrast
• Bright
To set the brightness of the LCD of the unit when displaying the
camera picture
• Cont
To set the contrast of the LCD of the unit when displaying the
camera picture
Memory Stick Memory Stick
Format
To perform formatting of the Memory Stick
44
Download from Www.Somanuals.com. All Manuals Search And Download.
Initial Settings
RCP Config. Menu
Setting the Operating Conditions
of the RCP-D50/D51
Exit
RCP
Adjusting
RE
Setting
By using the RCP Config menu or LCD setting
display, you can set the built-in clock of the RCP-D50/
D51 and adjust various conditions of the RCP-D50/
D51, such as the sound volume of the warning buzzer
and the brightness of the indicators and LCD.
Cable
Comp
SW
Setting
Camera
No.
Date
Time
Secu-
rity
To obtain the LCD setting display, press [LCD].
Displaying the RCP Config menu/LCD
setting display
The LCD setting display (page 48) appears.
Proceed as follows:
Setting the Built-in Clock
1
The RCP-D50/D51 has a built-in clock to record the
date and time when scene files are saved to Memory
Sticks.
PAINT 1 PAINT 2 PAINT 3 SCENE OTHERS FUNCTION MONITOR
MENU
To set the clock, proceed as follows:
Others Menu
Camera
1 Press the OTHERS button in the Menu operation
block so that the OTHERS menu is displayed on
the LCD, then press [RCP Config] to call the RCP
Config menu.
Adjusting
File
Config
2
RCP
Config
Memory
Stick
LCD
LCD
Moni.
2 Set the menu to Advanced Setting mode.
1)Press [Security] on the RCP Config menu.
2)Press and highlight [Engineer Mode].
MONITOR
BRIGHT
CONTRAST
The [Status], [Menu Set], and [Code No.]
buttons are displayed.
3)Press [Status].
The Security Status menu appears.
4)Press [Advance Mode].
1 Press to light the OTHERS button of the menu
operation block.
The OTHERS menu appears.
3 Press [Date/Time] on the RCP Config menu.
The current setting is displayed on the Date/Time
Set menu.
2 To display RCP Config menu, press
[RCP Config].
The RCP Config menu appears.
Date Time Set Menu
Exit
2001/11/17
(Sat)
22:12:31
Date
Time
45
Download from Www.Somanuals.com. All Manuals Search And Download.
Initial Settings
4 To set the date:
Adjusting the Buzzer Sound
1)Press and light [Date].
A buzzer sounds on the RCP-D50/D51 when it
receives call signal or a panel control is operated.
When required, you may turn on/off the buzzer or
adjust the sound volume.
Date Time Setting
Exit
2001/11/17
(Sat)
22:12:31
To adjust the buzzer, proceed as follows:
1 Press [RCP Adjusting] on the RCP Config menu.
Date
Year
Time
Set
Day
Cancel
Month
The RCP adjustment menu appears.
2001
8
8
Clear
Exit
Buzzer
Volume
LED
Bright
2)Set the Year, Month and Day with the left three
control knobs.
3)Press [Set].
The set date becomes valid.
To restore the previous setting, press [Cancel]
instead of [Set].
5 To set the time:
2 Press and light [Buzzer Volume].
1)Press and light [Time].
The lower half of the display becomes the Buzzer
Volume adjustment display.
Date Time Setting
Exit
Clear
Exit
2001/11/17
(Sat)
22:12:31
Buzzer
Volume
LED
Bright
Date
Hour
Time
Minute
32
Set
Second
25
Cancel
Buzzer
Volume
Call
Touch
Click
SW
Click
All
Buzzer
Off
17
Call
Touch
Switch
Master
50
50
50
50
2)Set the Hour, Minute and Second with the left
three control knobs.
3)Press [Set] in synchronization with a time
signal.
3 Adjust the levels with the corresponding control
knobs (50 is the standard value with all items).
Call: Sound volume of the buzzer when a call
signal is received
The set time becomes valid.
To resume the previous setting, press [Cancel]
instead of [Set].
Touch: Sound volume of the buzzer when a
button displayed on the menu display is operated
Switch: Sound volume of the buzzer when a
button on the panel is operated
The master volume can be adjusted with the
rightmost control knob (Master).
When the clock setting is completed
Press [Exit] to leave the menu.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
To turn on/off the buzzers independently
Press the corresponding button. When it is lit, the
buzzer is on.
[Call Buzzer]: For the buzzer sound when a call signal
is received
lamps, including the master black indicator and
f-number indicator
The master brightness can be adjusted with the
rightmost control knob (Master).
[Touch Click]: For the buzzer sound when a button
displayed on the menu display is operated
[SW Click]: For the buzzer sound when a button on
the panel is operated
When the adjustment is completed
Press [Exit] to leave the menu.
Changing the Functions of the
Rotary Encoders
To turn off all the buzzers
Press and light [All Off].
You can change the functions of BLACK/FLARE
control knobs.
Proceed as follows:
When the adjustment is completed
Press [Exit] to leave the menu.
1 Press [RE Setting] on the RCP Config menu to
Adjusting the Brightness of the
LEDs
obtain the Rotary Encoder Setting display.
RCP Config Menu
Exit
RE Setting
You can adjust the brightness of the LEDs of the panel
buttons and camera number/tally indication window.
To adjust the brightness, proceed as follows.
Rotary Encoder
Setting
1 Press [RCP Adjusting] on the RCP Config menu to
display the RCP adjustment menu.
BLACK / FLARE
Black
Flare
2 Press and light [LED Bright].
The lower half of the display becomes the LED
Brightness adjustment display.
2 When changing the function of the BLACK/
FLARE control knobs, press [Black] or [Flare] as
desired.
Clear
Exit
Buzzer
Volume
LED
When the adjustment is completed
Press [Exit] to leave the menu.
Bright
LED
Brightness
Switch
Tally
Other
Master
50
50
50
50
3 Adjust the brightness with the corresponding
control knobs (50 is the standard value with all
items).
Switch: Brightness of the built-in LEDs of the
control buttons
Tally: Brightness of the built-in LEDs of the
camera number/tally indication window
Other: Brightness of the other LED indicators/
47
Download from Www.Somanuals.com. All Manuals Search And Download.
Initial Settings
2 Set the menu to Advanced Setting mode.
1)Press [Security] on the RCP Config menu.
2)Press and highlight [Engineer Mode].
Adjusting the Brightness/
Contrast of the LCD
You can adjust the brightness and contrast of the
display of the menu control block.
Proceed as follows:
The [Status], [Menu Set], and [Code No.] buttons
are displayed.
3)Press [Status].
1 Press [LCD] on the OTHERS menu to display the
The Security Status menu appears.
4)Press [Advance Mode].
LCD setting display.
Clear
Exit
3 Press [SW Setting] on the RCP Config menu to
obtain the SW Setting display.
LCD Brightness
/Contrast
RCP Config Menu
Exit
SW Setting
Bright
Cont
SW Assign
NoAssign
Black/Flare
BlackAUTO
ATW
5
5
TLCS
DynaLatitude
Sel
2 Adjust Bright and Cont (5 is the standard value
with both items).
To adjust the brightness and contrast for
camera pictures
4 Turn the second left control knob (Sel) to highlight
the function to be assigned.
NoAssign (default): No assignment
Black/Flare: Switching the function of the
BLACK/FLARE knobs
1 Press [LCD Moni.] on the OTHERS menu to
display the LCD setting display.
Black AUTO: ON/OFF of the auto black
ATW: ON/OFF of the auto tracing white balance
TLCS: ON/OFF of the total level control function
DynaLatitude: ON/OFF of the DynaLatitude
function
2 Adjust Bright and Cont (5 is the standard value
with both items).
When the adjustment is completed
Press [Exit] to leave the menu.
Note
Some functions may be unoperative, depending on the
connected camera.
Assigning a Function to the
ASSIGN Button
When the assignment is completed
Press [Exit] to leave the menu.
You can assign a function to the ASSIGN button.
Note that the assignable functions depend on the
connected camera.
Proceed as follows:
1 Press the OTHERS button in the Menu operation
block so that the OTHERS menu is displayed on
the LCD, then press [RCP Config] to call the RCP
Config menu.
48
Download from Www.Somanuals.com. All Manuals Search And Download.
If you enter an incorrect security code, the message
“!!!Code No. NG!!!” is displayed.
Specifying the Security Codes
You can authorize specific persons to set the menu to
Engineer mode, to operate this panel, and to adjust the
iris and master black by specifying a security code.
When you enter the correct security code, the
Security Code setting display is resumed with
highlighted [Enable] and additional [Code
Change].
Locking Engineer mode with a security
code
After this setting, the Security Code input display
appears when you press [Engineer Mode] of the
Security menu.
1 Press the OTHERS button in the Menu operation
block so that the OTHERS menu is displayed on
the LCD, then press [RCP Config] to call the RCP
Config menu.
Releasing the security code lock of
Engineer mode
2 Set the menu to Engineer mode.
1 When a security code for Engineer mode has been
set, operate in the same manner as step 1 through
step 4 in “Locking Engineer mode with a security
code.”
1)Press [Security] on the RCP Config menu.
2)Press and highlight [Engineer Mode].
The [Status], [Menu Set], and [Code No.] buttons
are displayed.
The Security Code input display appears.
2 Enter the security code and press [Enter].
The security code lock is released.
3 Press [Code No.].
The Security Code setting display appears.
4 Press [Enable].
Locking panel operations, iris/master
black adjustments menu with a security
code (Panel Active Lock)
The Security Code input display now appears and
“Input New Code No.” is displayed.
1 Press the OTHERS button in the Menu operation
block so that the OTHERS menu is displayed on
the LCD, then press [RCP Config] to call the RCP
Config menu.
5 Enter a security code and press [Enter].
Use [0] to [9] to enter the security code (up to 8
digits).
2 Set the menu to Engineer mode.
Asterisks, each representing one digit of the
entered security code, are displayed in the upper
New Code No. box.
1)Press [Security] on the RCP Config menu.
2)Press and highlight [Engineer Mode].
The [Status], [Menu Set], and [Code No.] buttons
Press [Back Space] to cancel previous input one at
are displayed.
a time.
3 Press [Status].
When you press [Enter], the message “Input Again
to Confirm” is displayed.
The Security Status menu appears.
6 Enter the security code again and press [Enter].
4 Press B to display the second page and press
[Enable].
Asterisks, each representing one digit of the
entered security code, are displayed in the lower
New Code No. box.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
Initial Settings
The Security Code input display appears.
(Pressing [Enable $ENG Code%] registers the same
security code as Engineer mode for Panel Active
Lock.)
2 Press B to display the second page and press
[Disable].
The security code is disabled.
5 Operate in the same manner as step 5 and step 6 in
Changing a security code
“Locking Engineer mode with a security code.”
1 Press [Code Change] on the Security Code setting
The Security Status menu is resumed with
highlighted [Enable] and additional [Code
Change].
display.
The Security Code input display appears and the
message “Input Old Code No.” is displayed.
After this setting, when you hold the PANEL ACTIVE
button pressed for more than 2 seconds, the message
“!!Panel Locked!!” is displayed and the panel is
locked.
When the panel is locked, the Security Code input
display appears when you press the PANEL ACTIVE
or IRIS/M. BLACK ACTIVE button.
If the correct security code is not entered, the lock is
not released.
2 Enter the current security code and press [Enter].
Asterisks, each representing one digit of the
entered security code, are displayed in the Old
Code No. box.
When you press [Enter], the message “Input New
Code No.” is displayed.
Notes
3 Enter a new security code and press [Enter].
• If no security code has been set for Engineer mode,
[Enable $ENG Code%] is not displayed.
• When the panel is locked with a security code, the
panel lock is not released even when power to this
unit is shut off.
The message “Input Again to Confirm” is
displayed.
4 Enter the new security code again and press
The panel lock is released when you select Engineer
mode.
[Enter].
• When the panel is locked with a security code, only
Security from RCP Config can be selected in the
OTHERS menu.
The new security code becomes valid.
Note
• If you specify a security code only for Panel Active
Lock without setting a security code for Engineer
mode, Engineer mode is also locked with the security
code for Panel Active Lock when the panel is locked.
If no security code has been set, [Code Change] is not
displayed.
If you forget the specified security code(s)
Disabling the security code for Panel
Active Lock
1 Shut down power to the unit, then reapply power
while holding the MASTER and CLOSE buttons
pressed.
1 When Panel Active Lock has been enabled, operate
in the same manner as step 1 through step 3 in
“Locking panel operations, iris/master black
adjustments menu with a security code (Panel
Active Lock).”
The confirmation display for canceling the
securing code appears.
2 Press [OK].
The Security Code input display appears.
The message “Code No. cleared” is displayed, and
the security code settings are canceled.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
File Operations
This unit can operate two types of files: scene files and
setup files.
The table below shows the setting items which can be
registered as either of the files.
Setting data of cameras can be registered as scene files
or setup files and recalled as required.
Setup file
Scene file
Setting item
DXC-D30/D35
series only
DXC-D30/D35
series
DXC-D50
series
DXC-637
series
Selecting shooting picture or color bars
Master black
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
Iris
Auto iris mode
yes
yes
Master gain
TLCS
Upper limit value for AGC
Initial F-stop value for AGC
Initial F-stop value for AE
Shutter/Clear scan
yes
yes
yes
yes
yes
yes
yes
Shutter speed
Clear scan frequency
Filter position
Selecting white balance or black balance adjustment
ATW ON/OFF
yes
yes
yes
yes
yes
yes
yes
yes
yes
R/B white balance adjustment
R/B black balance adjustment
Flare correction ON/OFF
R/G/B flare correction
Detail correction ON/OFF
Detail level
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
Detail boost frequency
Crispening level
Level dependence value
Detail H/V
V-detail limit value
Highlight detail
After gamma detail
Aperture correction ON/OFF
Aperture correction value
Knee aperture correction ON/OFF
Knee aperture correction value
Cross color suppress value
R/G comb filter ON/OFF
Knee correction mode
Master knee point
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
Master knee slope
White clip circuit ON/OFF
White clip value
yes
51
Download from Www.Somanuals.com. All Manuals Search And Download.
File Operations
Setup file
Scene file
Setting item
DXC-D30/D35
series only
DXC-D30/D35
series
DXC-D50
series
DXC-637
series
Gamma correction on/off
Master gamma
yes
yes
yes
yes
yes
yes
yes
yes
R/B gamma
Master black gamma
R/B black gamma
Gamma initial gain
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
Black stretch level
Upper/lower limit value for black stretch
Upper/lower limit value for black compress
DynaLatitude effect
Matrix adjustment ON/OFF
Saturation/hue
yes
yes
yes
yes
yes
yes
yes
yes
Matrix adjustment mode
Matrix parameter (R-G, R-B, G-R, G-B, B-R, B-G)
Skin detail level
yes
yes
yes
yes
yes
yes
Skin matrix saturation/hue
Skin gate position/size
Position/size of skin gate detect window
EVS
yes
yes
Low Key saturation
Focus/zoom
yes
yes
yes
yes
yes
yes
Pan/tilt
ON/OFFselection of optional control 1 or 2
52
Download from Www.Somanuals.com. All Manuals Search And Download.
If the scene file button corresponding to the
memory cell in which you wish to store data is not
displayed, press either the v or V button at the
lower-right position. You can change the scene file
buttons by 5, in the order of [1] to [5], [6] to [10],
[11] to [15], and [16] to [20]. You can also change
the buttons one by one. When the knob at the
leftmost position (Page) is turned clockwise,
larger-numbered buttons are displayed one by one.
When the knob is turned counterclockwise,
smaller-numbered buttons are displayed in turn.
Operating Scene Files
Scene files are stored in the memory of this unit (or of
the camera when using the DXC-D50-series camera).
Among the setting items listed in the table on pages 51
and 52, the settings for those items that have “yes” in
the scene-file column can be stored as a scene file. Up
to 20 scene files can be registered and retrieved as
required. To register or retrieve scene files, use the
Scene File Operation menu.
The selected file number is displayed above the
filename input box.
Registering a scene file
Use the Scene File Operation menu for storing a scene
file, in the following manner:
Retrieving a scene file
1 Make the adjustment for the setting items that have
“yes” in the scene-file column in the table on pages
51 and 52, until the values you wish to store are
obtained.
Use the Scene File operation menu for retrieving a
scene file.
1 Press the SCENE button in the menu operation
block to display the Scene File Operation menu on
the LCD.
2 Press the SCENE button in the menu operation
block to display the Scene File operation menu on
the LCD.
2 Press either the v or V button, or turn the knob at
the leftmost position (Page) until the file button
corresponding to the desired file is displayed.
Scene Files
Store
3 Press the button corresponding to the scene file to
1
2
3
4
5
be retrieved.
Scene 1 : STUDIO1
Scene 2 : DXC-D30
Scene 3 : TEST 002
Scene 4 :
Scene :
DXC_D
2*
The selected scene file is retrieved, and the settings
of the camera are replaced with the data of the
retrieved file.
Scene 5 :
Page
Char
Cur
3 Press [Store].
4 Enter a filename (up to eight characters) in the
filename input box.
Moving the cursor: Turn the rightmost knob
(Cur) until the cursor comes to the position
where you wish to enter a character.
Selecting a character: Turn the second knob
(Char) from the left until the character which
you wish to enter appears.
5 Press a scene file select button (1 to 20)
corresponding to the memory cell in which you
wish to store the setting data.
53
Download from Www.Somanuals.com. All Manuals Search And Download.
File Operations
Reading the scene files from a Memory
Stick
Transferring Scene Files between
the Camera and a Memory Stick
(with the DXC-D50 Series)
Proceed as follows:
1 Insert the Memory Stick (see page 59).
When a DXC-D50-series camera is connected, the
registered scene files can be stored as a data block and
can be read when required.
2 Operate in the same manner as when you stored
the files until the Scene File Transfer display
appears.
Storing the scene files on a Memory Stick
3 Press [MS -> CAM].
Proceed as follows:
A confirmation display appears.
1 Insert the Memory Stick (see page 59).
4 Press [Start].
The scene files are transferred from the Memory Stick
2 Press the OTHERS button in the Menu operation
block so that the OTHERS menu is displayed on
the LCD, then press [RCP Config] to call the RCP
Config menu.
to the connected camera.
When the transfer is finished
The termination message “COMPLETED” appears.
3 Set the menu to Advanced Setting mode.
1)Press [Security] on the RCP Config menu.
2)Press and highlight [Engineer Mode].
The [Status], [Menu Set], and [Code No.]
buttons are displayed.
3)Press [Status].
The Security Status menu appears.
4)Press [Advance Mode].
4 Return to the OTHERS menu, and press [File].
5 Press [File Trans].
The Scene File Transfer display appears.
6 Press [CAM -> MS].
A confirmation display appears.
7 Press [Start].
The registered scene files are transferred to the
Memory Stick.
When the transfer is finished
The termination message “COMPLETED” appears.
54
Download from Www.Somanuals.com. All Manuals Search And Download.
5 Press [Store].
Operating Setup Files (for DXC-
D30/D35 Series only)
The current settings of the camera are stored as a
setup file with the name entered in Step 4, and that
filename is displayed on the list.
Among the setting items listed in the table on pages 51
and 52, the settings for those items that have “yes” in
the Setup-file column are stored as a setup file in the
memory of the camera. In addition to five files
Retrieving a setup file
(PRESET 1 to PRESET 5) that have already been
registered in the camera, three more files (USER 1 to
USER 3) can be registered and retrieved as required.
1 Call the Setup File operation display, then turn the
knob at the leftmost position (Sel) to select the file
you wish to retrieve from among PRESET 1 to
PRESET 5 (preset files 1–5) and USER 1 to USER
3 (user’s registration files 1–3) from the list.
To register or retrieve setup files, use the Setup File
operation display.
2 Press [Recall].
Registering a setup file
The selected file is retrieved, and the settings of the
camera are replaced with the data of the retrieved
file.
1 Press the OTHERS button in the menu operation
block to display the OTHERS menu on the LCD,
then press [File] to call the File menu.
2 Press [Setup File].
The Setup File operation display appears.
Setup Files
Exit
PRESET 1 : STD
PRESET 2 : HISAT
PRESET 3 : FL
Recall
PRESET 4 : FILMLIKE
PRESET 5 : SVHS/VHS
USER 1 : USER 1
USER 2 : USER 2
USER 3 : USER 3
Sel
DXC_D
Store
Cur
Char
3 Turn the knob at the leftmost position (Sel) to
select a file to which you wish to register data
among USER 1 to USER 3 (user’s registration files
1-3) from the list.
4 Enter a filename (up to eight characters) in the
filename input box.
Moving the cursor: Turn the rightmost knob
(Cur) until the cursor comes to the position
where you wish to enter a character.
Selecting a character: Turn the second knob
(Char) from the right until the character which
you wish to enter appears.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
Skin Detail Correction/Skin Matrix Adjustment (for
DXC-D30/D35/D50 Series Only)
The skin detail and skin matrix functions can adjust
detail level and matrix (saturation and hue) of a
selected skin gate area (area designated by color
range).
Once a skin gate area has been selected, it can be used
as a target for both skin detail correction and skin
matrix adjustment, and activation of each function can
be performed independently.
If you power off the unit or store the current
settings as a scene file while setting the detail level
to the minimum value, the skin detail function will
be set to off when you power on the unit or recall
the scene file next time.
To store the skin detail settings
Set the SKIN DETAIL button on before powering off
the unit or storing the settings as a scene file. If the
button is off, the skin detail settings will not be stored.
Selecting the skin gate area
Normally, use the SKIN DTL SETUP button of the
AUTO SETUP block to designate the skin gate
position (target color) automatically.
Performing skin matrix adjustment
Follow the procedure described below to adjust the
matrix (saturation and hue) of the skin gate area.
1 Press and light the SKIN DTL SETUP button
1 Select [Skin Matrix] in Paint menu 3.
(ON).
2 Set [Skin Matrix] to ON.
The window which shows the skin gate and target
area appears in the camera’s viewfinder.
You can also see the skin gate with a picture
output from the CCU’s PIX connector.
3 Set the saturation and hue using the leftmost
control knob (Hue) or the second control knob
(Sat) from the left.
2 Press the START button.
Selecting 00 causes the same situation as the skin
matrix function is set off.
The skin gate is designated automatically.
If you power off the unit or store the current
settings as a scene file while selecting 00, the skin
matrix function will be set to off when you power
on the unit or recall the scene file next time.
When using a DXC-D30/D35-series camera, you can
manually adjust the position of the designated skin
gate in Paint menu.
Note
When using the DXC-D30 series, this adjustment is
valid when the matrix adjustment function is active.
Performing skin detail correction
By skin detail correction, you can lower the detail level
of the skin gate area to the detail level outside of the
area.
To store the skin matrix settings
Activate both the matrix adjustment and skin matrix
adjustment functions before powering off the unit or
storing the settings as a scene file. Otherwise, the skin
matrix settings will not be stored.
1 Press and light the SKIN DETAIL button (ON).
2 Select [Skin Detail] in Paint menu 2.
3 Set the detail correction level using the leftmost
control knob (Level).
Setting the level to the max. value (+99): The
detail level of the area is set to the lowest level.
Setting the level to the min. value (0): The detail
level of the area is set to the same level with the
outside of the area. (The same situation as the
skin detail function is set to off.)
56
Download from Www.Somanuals.com. All Manuals Search And Download.
Multi-Camera Control
Connections and Preparatons
Adjusting the Iris/Master Black
of Multiple Cameras at One Time
In a multi-camera system, connecting all the CCU-
TX7 units via the RS232C connectors allows one RCP
unit selected from all the RCP units in the system to
control the multiple cameras.
If the selected unit is set as the master unit and the rest
are set as slave units, the setting data of the camera
connected to the master unit can be transferred to other
cameras.
For iris and master black adjustments, you can use any
one of the RCP units (whether it is the master unit or a
slave unit) specified with the IRIS/M.BLACK LINK
button.
1 Select the cameras for which you will adjust the
iris or master black by pressing the IRIS/
M.BLACK LINK buttons on the connected RCP
units. (The buttons light when pressed.)
To make connections among the CCU-TX7
units
Connect RS-232C cross (or reverse) cables with D-sub
25-pin plugs (not supplied) to the RS232C connectors
on each CCU to make a daisy chain of the CCUs.
2 Adjust the iris or master black on one RCP unit
whose IRIS/M.BLACK LINK button lights.
For more information about cables which can be used,
consult your Sony dealer.
On the cameras connected to the RCP units whose
IRIS/M.BLACK LINK buttons light, the iris or
master black adjustments are performed by the
same amount and at the same time (on relative
mode).
Notes
• It is impossible to assure that all the cameras can be
set up to the same conditions under the multi-camera
control. Setting purposes and the current condition of
each camera may cause variation of the setting
condition.
Note
The IRIS/M.BLACK LINK function is released while
transferring the scene files.
• In a system which contains more than two types of
cameras, the setting items, adjustment range and
adjustment accuracy available at the multi-camera
operation are determined depending on the efficiency
of the camera connected to the master unit.
• There are two setting modes: Absolute mode and
Relative mode.
Data Transfer Among Multiple
Cameras
The settings made on the master unit can be transferred
to the cameras connected to the slave units, if they can
be registered as a scene file.
• Settings performed on a slave unit are valid only to
the connected camera.
Perform as follows:
Setting a unit to the master unit or a slave
unit
1 Select [File] from the OTHERS menu, and press
[Copy to Slaves].
Note
Perform the following procedure after making sure all
the cameras in the system are powered on. Note that
executing the procedure when there is any cameras
powered off may result in failure.
2 Press [Start].
Data transfer begins.
Meanwhile, on all the linked RCP units (including
units selected as neither the master unit nor slave
units), the message “IN PROGRESS” is displayed on
the LCD and all buttons and knobs are locked.
1 Select one RCP unit for the master unit, and press
the MASTER button. (The button lights when
pressed.)
When the data transfer completes, the message
“COMPLETED” appears on the LCD. The LCD soon
returns to the original status.
2 Select one RCP unit (or more) for a slave unit, and
press the SLAVE button. (The button lights when
pressed.)
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Multi-Camera Control
Notes
• The command link adjustment of R/G/B flare
correction is available only with the DXC-D30/D35/
D50 series.
• While scene file transfer is in progress on a slave
unit, do not tranfer data from the master unit to the
slave unit. Scene file transfer will fail.
• The master/slave setting is released while transferring
the scene files.
Activating command link adjustments/
settings
1 Press the OTHERS button in the Menu operation
block so that the OTHERS menu is displayed on
the LCD, then press [RCP Config] to call the RCP
Config menu.
Operating Multiple Cameras from
One RCP Unit —Command Link
Command link allows one RCP selected as the master
unit to control the adjustments or settings of the
cameras connected to the slave units.
To perform command link operation, activate the
command link on the Command Link operation
display on the master unit.
2 Set the menu to Advanced Setting mode.
1)Press [Security] on the RCP Config menu.
2)Press and highlight [Engineer Mode].
The [Status], [Menu Set], and [Code No.]
buttons are displayed.
Note
3)Press [Status].
The Command Link operation display can be
displayed from the RCP Config menu only in
Advanced Setting mode.
The Security Status menu appears.
4)Press [Advance Mode].
3 Return to the RCP Config menu, and press
Command Link items
[Comm Link].
• Gain setting (Absolute mode)
• Shutter settings (Absolute mode)
- Shutter on/off
The Command Link Items are displayed.
- Clear scan mode on/off
- EVS function on/off
RCP Config Menu
Exit
Command Link Item
- Shutter speed
- Clear scan frequency
R/B
White
Gain
• R/B manual white balance adjustment (Relative
mode)
R/B
Shutter
Black
• R/B manual black balance adjustment(Relative
mode)
R/G/B
Flare
• R/G/B manual flare correction (Relative mode)
Notes
• Do not perform command link operation in a system
containing multiple cameras of different types. If the
camera connected to a slave unit is different in type
from the camera connected to the master unit,
changing the gain value on the master unit will set the
gain value of the camera connected to the slave unit
to 0 dB or the LOW position. The CLS frequency
does not exceed the limit for the camera.
4 Press and highlight the button for the item for
which you wish to activate the command link.
5 Press [Exit] to leave the menu.
When you adjust the item for which you wish to
activate the command link on the master unit, the
adjustment becomes valid on the cameras
connected to the slave units.
• When adjusting the white balance, black balance and
flare with the command link, select Manual
Adjustment mode for white balance, black balance
and flare also on slave units.
58
Download from Www.Somanuals.com. All Manuals Search And Download.
Memory Sticks
Using a Memory Stick
Notes on Memory Stick
When a Memory Stick is inserted in the panel, the file
data can be stored on the Memory Stick, which
enables you to share data among RCPs.
On Memory Stick
Memory Stick is a new compact, portable and
versatile IC recording medium with a data capacity
that exceeds that of a floppy disk. Memory Stick is
specially designed for exchanging and sharing digital
data among Memory Stick compatible products.
Because it is removable, Memory Stick can also be
used for external data storage.
Inserting a Memory Stick
Insert a Memory Stick with the label side to the left
into the Memory Stick slot until it clicks and the
access lamp lights in red.
Types of Memory Stick
Label side
There are two types of Memory Stick: “MagicGate
Memory Stick” that are equipped with the MagicGate
copyright protection technology and general “Memory
Stick.” You can use either type of Memory Stick with
your camera. However, because your camera does not
support the MagicGate standards, data recorded with
your camera is not subject to MagicGate copyright
protection.
Access lamp
Memory Stick
EXT
On MagicGate
MagicGate is copyright-protection technology that
uses encryption technology.
Note
Structure of Memory Stick
Never insert/remove a Memory Stick while the access
lamp is lit in red.
Terminal
To remove a Memory Stick
If you push the inserted Memory Stick, the Memory
Stick will pop out a little. Then pull the Memory
Stick out.
Write-Protect tab
Access lamp
The access lamp shows the status of the Memory
Stick.
Off: No Memory Stick is inserted.
Lit in green: There is a Memory Stick in the slot. In
this condition, you can safely eject the Memory
Stick.
Labeling position
You cannot record or erase data when the write-protect
tab on the Memory Stick is set to LOCK.
Lit in red: Data are being read/written. If you eject
the Memory Stick in this condition, the data are
not guaranteed. All the data may be lost.
We recommend backing up important data.
59
Download from Www.Somanuals.com. All Manuals Search And Download.
Memory Sticks
Handling of Memory Stick
• Image data may be damaged in the following cases:
– If you remove the Memory Stick, or turn the power
off when the access lamp is lit in red
– If you use a Memory Stick near static electricity or
a magnetic field
We recommend backing up important data.
• Prevent metallic objects or your finger from coming
into contact with the terminal of the connecting
section.
• Do not attach any material other than the supplied
label to the label space.
• Attach the label at the prescribed labeling position.
Make sure the label is attached at the labeling
position properly.
• Do not bend, drop, or apply strong shock to a
Memory Stick.
• Do not disassemble or modify a Memory Stick.
• Do not let the Memory Stick get wet.
• Do not use or keep a Memory Stick in locations that
are:
– Extremely hot such as in a car parked in the sun
– Under direct sunlight
– Very humid or subject to corrosive gases
• When you carry or store a Memory Stick, keep it in
its case.
• Memory Sticks of the sizes that can be used with the
RCP-D50/D51 may not be used with some cameras.
To exchange the setting data with a camera via a
Memory Stick, be sure to use Memory Sticks of a
size that can be used with both the RCP-D50/D51 and
the camera.
Memory Stick and
Corporation.
MagicGate Memory Stick and
are the trademarks of Sony
are the
trademarks of Sony Corporation.
60
Download from Www.Somanuals.com. All Manuals Search And Download.
Specifications
General
Power requirements 10.5 to 17 V DC
Power consumption 4.5 W
Cable length
50 m (164 feet) max.
(when the CCA-7 cable is used)
Operating temperature
5°C to 40°C (41°F to 104°F)
Dimensions (w/h/d) RCP-D50:
102 × 354 × 126.5 mm
(4 1/8 × 14 × 5 inches)
RCP-D51:
102 × 354 × 86.5 mm
(4 1/8 × 14 × 31/2 inches)
RCP-D50: 1.5 kg (3 lb 5 oz)
RCP-D51: 1.3 kg (2 lb 14 oz)
Mass
Inputs/outputs
CCU/CAMERA
MONITOR
EXT I/O
10-pin multiconnector (1)
BNC type (1)
9-pin D-sub connector (1)
Supplied accessories
Remote cable CCA-7-5 (5 m) (1)
Operating instructions (1 set)
Optional accessories
Remote cable CCA-7-5 (5 m)
Remote cable CCA-7-25 (25 m)
Memory Stick
Design and specifications are subject to change
without notice.
61
Download from Www.Somanuals.com. All Manuals Search And Download.
Sony Corporation
Download from Www.Somanuals.com. All Manuals Search And Download.
|