DME PROCESSOR PACK
MVE-9000-C
MULTI FORMAT DME PROCESSOR
MVE-9000
HK-PSU04
MKE-9020M
MKE-9021M
MKE-9040M
INSTALLATION MANUAL
1st Edition
Download from Www.Somanuals.com. All Manuals Search And Download.
For MVE-9000
Attention-when the product is installed in Rack:
1. Prevention against overloading of branch circuit
When this product is installed in a rack and is
supplied power from an outlet on the rack, please
make sure that the rack does not overload the supply
circuit.
2. Providing protective earth
When this product is installed in a rack and is
supplied power from an outlet on the rack, please
confirm that the outlet is provided with a suitable
protective earth connection.
3. Internal air ambient temperature of the rack
When this product is installed in a rack, please make
sure that the internal air ambient temperature of the
rack is within the specified limit of this product.
4. Prevention against achieving hazardous
condition due to uneven mechanical loading
When this product is installed in a rack, please make
sure that the rack does not achieve hazardous
condition due to uneven mechanical loading.
5. Install the equipment while taking the operating
temperature of the equipment into consideration
For the operating temperature of the equipment, refer
to the specifications of the Operation Manual.
6. When performing the installation, keep the rear of
the unit 10 cm (4 inches) or more away from walls
in order to obtain proper exhaust and radiation of
heat.
For MVE-9000
When using a LAN cable:
For safety,do not connect to the connector for
peripheral device wiring that might have excessive
voltage.
MVE-9000 IM
1 (P)
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Manual Structure
Purpose of this manual .............................................................................................. 2
Related manuals......................................................................................................... 2
Contents ..................................................................................................................... 2
Trademark.................................................................................................................. 2
1. Installation
1-1. Operating Environment ............................................................................... 1-1
1-2. Power Supply .............................................................................................. 1-1
1-2-1. Power Specifications .................................................................. 1-1
1-2-2. Recommended Power Cord........................................................ 1-2
1-3. Installation Space (External dimensions) .................................................... 1-3
1-4. Installing the Options .................................................................................. 1-4
1-4-1. Installing the Plug-in Boards...................................................... 1-4
1-4-2. Installing the Connector Board .................................................. 1-6
1-4-3. Installing the HK-PSU04 ........................................................... 1-7
1-5. Rack Mounting ............................................................................................ 1-8
1-6. Matching Connectors and Cables..............................................................1-10
1-7. Input/Output Signals of Connectors .......................................................... 1-11
1-8. Checks on Completion of Installation .......................................................1-12
1-8-1. On-board Switches Setting and LED Functions ...................... 1-12
1-9. System Connection.................................................................................... 1-22
2. Service Overview
2-1. Troubleshooting .......................................................................................... 2-1
2-2. Periodic Inspection and Maintenance ......................................................... 2-2
2-2-1. Cleaning ..................................................................................... 2-2
2-3. About the Data Backup Capacitor............................................................... 2-2
MVE-9000 IM
1
Download from Www.Somanuals.com. All Manuals Search And Download.
Manual Structure
Purpose of this manual
This manual is the installation manual of DME Processor Pack MVE-9000-C and
their optional boards and units.
This manual is intended for use by trained system and service engineers, and
describes the information on installing the MVE-9000-C system.
Related manuals
The following manuals are prepared for MVE-9000-C and their optional boards and
units.
. Operation Manual (Supplied with MVE-9000-C)
This manual describes the application and operation of MVE-9000-C system.
. Maintenance Manual (Available on request)
This manual describes the detailed service information.
If this manual is required, please contact your local Sony Sales Office/Service
Center.
Contents
This manual is organized by following sections.
Section 1 Installation
This section describes the operating environment, power supply, installation space,
installation of optional boards and units, rack mounting, connectors, input and
output signals of connectors, checking upon completion of installation, and system
configuration.
Section 2 Service Overview
This section describes the troubleshooting and periodic inspection and maintenance.
Trademark
Registered trademark used in this manual is follows.
. Ethernet is a registered trademark of Xerox Corporation.
MVE-9000 IM
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 1
Installation
1-1. Operating Environment
1-2. Power Supply
Operating guaranteed temperature : +5 dC to +40 dC
1-2-1. Power Specifications
Performance guaranteed temperature : +10 dC to +35 dC
Operating humidity :
(relative humidity)
Storage temperature :
10 % to 90 %
A switching regulator is used for the power supply of this
unit. The voltage within the range of 100 V to 240 V can
be used without changing the supply voltage.
_20 dC to +60 dC
Mass (when all options are installed) : Approx. 27 kg
Power requirements :
Power frequency :
Current consumption (when all options are installed) :
6.0 to 2.5 A
AC 100 to 240 V 10 %
50/60 Hz
Prohibited locations for installation
. Areas where the unit will be exposed do direct sunlight
or any other strong lights.
. Dusty areas
. Areas subject to vibration.
m
. Areas with strong electric or magnetic fields.
. Areas near heat sources.
. Areas subject to electrical noise.
. Areas subject where is subjected to static electricity.
. As the inrush current at turn-on is a maximum 110 A (at
100 V)/220 A (at 240 V), the capacity of the AC power
source must be commensurate with this load.
If the capacity of the AC power is not adequately large,
the AC power source braker will operate or the unit will
abnormally operate.
Ventilation
The inside of the MVE-9000-C is cooled by a fan (both
sides).
The power supply can be damaged if the exhaust vent
(both sides) and air intake (front panel) are blocked or the
fan is stopped.
. The MVE-9000 contains the single power supply unit as
the standard configuration. A maximum of two power
supply units may be installed. When starting up the
MVE-9000, be sure to turn on the power of one or more
power supply units.
Therefore, leave a blank space of more than 10 cm in the
front and both sides of the MVE-9000-C.
MVE-9000 IM
1-1
Download from Www.Somanuals.com. All Manuals Search And Download.
1-2-2. Recommended Power Cord
This unit does not come with a power cord.
To get a power cord, please contact your local Sony Sales
Office/Service Center.
w
. Use the approved Power Cord (3-core mains lead)/
Appliance Connector/Plug with earthing-contacts that
conforms to the safety regulations of each country if
applicable.
. Use the Power Cord (3-core mains lead)/Appliance
Connector/Plug conforming to the proper ratings (Volt-
age, Ampere).
If you have questions on the use of the above Power Cord/
Appliance Connector/Plug, please contact your local Sony
Sales Office/Service Center.
w
. Never use an injured power cord.
. Plugging the power cord in the AC inlet, push as far as it
will go.
For customers in the U.S.A. and Canada
1 Power cord, 125 V 10 A (2.4 m) : ! 1-557-377-11
AC inlet
1
For customers in the all European countries
1 Power cord, 250 V 10 A (2.4 m) : ! 1-782-929-21
AC inlet
1
MVE-9000 IM
1-2
Download from Www.Somanuals.com. All Manuals Search And Download.
1-3. Installation Space (External dimensions)
482
465
440
375
144.5
115.5
380
115.5
61
Unit : mm
MVE-9000 IM
1-3
Download from Www.Somanuals.com. All Manuals Search And Download.
1-4. Installing the Options
Installation procedure
1. Turn off the main power of the MVE-9000 and
disconnect the AC power cord from the wall outlet.
2. Loosen the four screws (with drop-safe) and remove
the front panel in the direction of the arrow.
The MVE-9000-C is shipped from the factory with the
necessary option (refer to the following table) already
installed in the MVE-9000, in accordance with the speci-
fied system configuration.
MVE-9000-C options
Screws
(with drop-safe)
Model name
Board configuration
Plug-in board Connector board
MKE-9020M
MVS Interface Board Set
_
CN-2357A board
CN-2357B board
MKE-9021M
Input/Output Board Set
_
CN-2355A board
CN-2355B board
MKE-9040M
DVP-24A board
Advanced Effects Board
HK-PSU04
_
_
Power Supply Unit
Front panel
1-4-1. Installing the Plug-in Boards
Screws
(with drop-safe)
c
Be sure to turn off the POWER switch and unplug the
power cord from the wall outlet before starting the installa-
tion work.
If the installation work is started with the POWER switch
left on, it may cause electrical shock or damage of printed
circuit boards.
3. Remove the four screws (B3 x 5), and remove the
“plug-in board loose-proof assembly”.
B3 x 5
Plug-in board
loose-proof assembly
B3 x 5
MVE-9000 IM
1-4
Download from Www.Somanuals.com. All Manuals Search And Download.
4. While the eject levers are kept open as shown in the
illustration, insert the plug-in board into the board
guide rails.
5. While closing the eject levers in the direction of arrow
1, push in the plug-in board.
1
1
Eject lever
Eject lever
Eject levers
6. Attach the plug-in board loose-proof assembly and the
front panel by reversing the installation steps 2, 3.
Name of option
Name of board
Slot on the front side
MKE-9040M
DVP-24A board*1 3, 4, 5, 6
*1 : The DVP-24A boards are assigned to the following channels in
accordance with the slots to which the boards are inserted.
Slot
Channel
3
4
5
6
CH1
CH2
CH3
CH4
MVE-9000 IM
1-5
Download from Www.Somanuals.com. All Manuals Search And Download.
1-4-2. Installing the Connector Board
The board slot
In the case of MKE-9020M
Parts required (Supplied accessory of MKE-9020M)
. Connecting cable
. Harness support
. Cover panel
. Screws (Two of PSW3 x 6)
Name of option
Name of board
Slot on the rear side
MKE-9020M
CN-2357A board
CN-2357B board
CN-2355A board
CN-2355B board
3
5
3
5
Perform the following procedures after step 1.
2. While the board levers are kept open as shown in the
illustration, insert the connector board into the board
guide rails.
MKE-9021M
Installation procedure
3. While closing the board levers in the direction of
arrow 1, push in the connector board and secure it
with the two screws.
1. Remove the two screws and remove the blank panel.
n
Store the removed blank panel in a safe location.
1
2
3
1
2
3
4
5
6
7
8
B3 x 5
Fixing screw
Blank panel
Connector board
B3 x 5
Fixing screw
The following procedures vary with the options.
In the case of other than MKE-9020M
2. Insert the connector board horizontally level and
secure it with the two fixing screws.
1
1
Board lever
Board lever
1
2
3
(Continued)
Fixing screw
Connector board
Fixing screw
MVE-9000 IM
1-6
Download from Www.Somanuals.com. All Manuals Search And Download.
1-4-3. Installing the HK-PSU04
4. Remove the blank panel from the slots 2 and 4.
5. Attach the cover panel and secure it with the two
screws.
The HK-PSU04 is used after it is installed in the MVE-
9000.
c
Before installing the HK-PSU04, be sure to turn off the
main power. If the HK-PSU04 is installed while the main
power is turned on, it can result in electrical shock or
damage to printed circuit boards.
1
2
3
4
5
Installation procedure
1. Remove the front panel of the MVE-9000.
(Refer to Section 1-4-1.)
6
7
8
B3 x 5
2. Remove the two screws (B3 x 5) fixing the PS cover,
and remove the PS cover.
3. Remove the two screws (PSW3 x 6) fixing the blank
panel, and remove the blank panel.
n
Cover panel
B3 x 5
Store the removed blank panel in a safe place.
6. Attach the connecting cable on the harness support.
7. Connect the connecting cable to the connector.
8. Secure the harness support to the cover panel using the
two screws supplied with MKE-9020M.
Blank panel
B3 x 5
PSW
3 x 6
1
2
3
4
5
B3 x 5
PS cover
6
7
8
4. Push the portion of the HK-PSU04 indicated by the
arrow and insert the HK-PSU04 into deep end as far as
it will go.
5. Secure the HK-PSU04 with the two screws removed in
step 3.
PSW3 x 6
Connecting cable
HK-PSU04
PSW3 x 6
Harness support
PSW3 x 6
6. Install the PS cover and the front panel by reversing
the installation steps of 1, 2.
MVE-9000 IM
1-7
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Rack mounting procedure
1-5. Rack Mounting
This section describes the rack mounting procedure using
the RMM-10 rack mount kit.
The MVE-9000 installs in a 19-inch standard rack.
To mount the MVE-9000 in a rack, use the specified rack
mount kit and follow the procedure described below.
n
Tighten the screws to the following torque.
Tightening torque : 120 x 10_2 N.m {12.2 kgf.cm}
Specified rack mount kit : RMM-10
n
1. Attach the rack tool to the side of the equipment using
If a rack mount kit other than the specified one is used, the
the specified six screws.
unit may not be correctly install in a 19-inch standard rack.
n
Use B4 x 6 screws.
Parts of the RMM-10
. Rack tools
2 pcs
1 pc
1 pc
Rack tool
B4 x 6
. Right rack mount adaptor
. Left rack mount adaptor
. Rack tool attaching screws
(B4 x 6 : 7-682-560-09)
. Rack tool attaching screws
(B4 x 10 : 7-682-560-10)
6 pcs
6 pcs
1. Precautions for rack mounting
w
. To prevent the rack from falling or moving, fix the rack
on a flat and steady floor using bolts or other fixings.
If the rack falls due to the weight of the equipment, it
may cause death or injury.
. Be sure to use the specified rack mount kit.
If not, injury may result and the equipment may fall due
to insufficient strength.
Rack tool
B4 x 6
. After rack mounting, be sure to tighten the screws on the
rack angle and fix the unit in the rack.
If the screws on the rack angle are not tightened, the unit
may slip from the rack and fall, causing injury.
2. Loosen the screws on the rear of the right and left
adaptors and adjust the length of the adaptor according
to the depth of the rack.
(The illustration below shows the left adaptor.)
c
When mounting the unit in the rack, note the following:
. Be sure to mount in the rack with two persons or more.
. Be careful not to catch your fingers or hands in the rack
mount rail or others.
Adaptor
. Mount in the rack in a stable position.
Portion of
the rail
n
B4 x 6
If several units are mounted in a rack, it is recommended
that a ventilation fan is installed to prevent temperature rise
inside the rack.
B4 x 6
n
Maximum depth of adaptor :750 mm
Minimum depth of adaptor : 595 mm
MVE-9000 IM
1-8
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Attach the right and left adaptors to the rack complete-
ly using the specified six screws.
7. Fix the rack angles in the rack using the specified
screws.
(The illustration below shows the left adaptor.)
Rack
31.75
Rack angle
B4 x 10
3U
B4 x 10
31.75
B5 x 12
Unit : mm
4. Tighten the screws (B4 x 6 : two screws each on the
right and left) for adjusting the length of the adaptor
completely (the screws that were loosened in step 2).
5. Align the groove of the rack tool at the side of the
equipment with the rail, and slide the equipment to the
rear.
B5 x 12
n
Rack angle
The rack tools are hooked on the rails as shown below.
8. Install the front panel to the equipment.
Rack tool
Rail
Rack tool
Rail
6. Remove the front panel. (Refer to Section 1-4-1.)
MVE-9000 IM
1-9
Download from Www.Somanuals.com. All Manuals Search And Download.
1-6. Matching Connectors and Cables
Use the following connectors, cables or equivalents when connecting cables to the unit.
Model name
Panel indication
Connector name
Matching connector and cable
Name
Sony part No.
MVE-9000
REF IN
BNC, 75 Z
BNC, 75 Z
EXT IN 1-4
MONI OUT 1-4
BELDEN 8281 coaxial cable
REMOTE 1-4
D-sub 9-pin, Female
D-sub 25-pin, Female
D-sub 9-pin, Male
Connector 9-pin, Male
Junction Shell 9-pin
1-560-651-00*1
1-561-749-00
GPI
GPI2
D-sub 25-pin, Male
Connector 25-pin, Male
Junction Shell 25-pin
1-560-904-11*1
1-563-377-11
DATA
CTRL
RJ-45 modular jack*2
MDR 68-pin, Female
BNC, 75 Z
_
_
MKE-9020M
MKE-9021M
SWITCHER A, B
Dedicated cable
(Supplied accessory of MKE-9020M)
_
IN V1-V4
BNC, 75 Z
IN K1-K4
BELDEN 8281 coaxial cable
OUT V1-V4
OUT K1-K4
*1 : The following crimp contact is required for the plug.
AWG#18 to #22 : 1-566-493-21
AWG#22 to #24 : 1-564-774-11
AWG#24 to #30 : 1-564-775-11
*2 : Conforms to the IEEE 802.3 Ethernet100BASE-TX standards.
MVE-9000 IM
1-10
Download from Www.Somanuals.com. All Manuals Search And Download.
GPI, GPI2 : (D-sub 25-pin, Female)
INPUT x 8, TTL
1-7. Input/Output Signals of Connectors
OUTPUT x 4, relay contacts 30 V 0.1 A
(resistive load)
OUTPUT x 4, open collector 30 V rated voltage
The input/output signals of the connectors at the rear panel
are as follows.
n
13
25
1
<CONTROLLER> indicates a controlling device.
<DEVICE> indicates a controlled device.
14
_ EXT VIEW _
REMOTE 1-4 : RS-422A (D-sub 9-pin, Female)
<DEVICE> (*1)
Pin No.
Signal Name
Function
1
GND
Ground
Ground
1
5
2
GND
9
6
3
GPI IN 2
General-purpose input
_ EXT VIEW _
4
GPI IN 4
5
GPI IN 6
Pin No.
Signal Name
Function
6
GPI IN 8
1
2
3
4
5
6
7
8
9
FG
Frame ground
Transmitted data (_)
Received data (+)
Ground
7
GPI OUT 1B
GPI OUT 2B
GPI OUT 3B
GPI OUT 4B
GPI OUT 6
GPI OUT 8
General-purpose relay output (B)*2
TX_
RX+
GND
_
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
No Connection
Ground
General-purpose open collector
output*3
GND
TX+
RX_
_
Transmitted data (+)
Received data (_)
No Connection
GPI OUT COM Ground for open collector output
GND
Ground
GPI IN 1
General-purpose input
GPI IN 3
(*1) : Editing control unit such as BVE-9100 (EDITOR)
GPI IN 5
GPI IN 7
DATA
CTRL : 100BASE-TX, RJ-45 (8-pin)
GPI OUT 1A
GPI OUT 2A
GPI OUT 3A
GPI OUT 4A
GPI OUT 5
GPI OUT 7
General-purpose relay output (A)*2
8
1
General-purpose open collector
output*3
_ EXT VIEW _
Pin No.
Signal Name
Function
GPI OUT COM Ground for open collector output
1
2
3
4
5
6
7
8
TX+
TX_
RX+
_
Transmitted data (+)
Transmitted data (_)
Received data (+)
No Connection
n
A and B of the same number constitute a pair of relay contacts.
(*2)<Relay>
GPI OUT n B
_
No Connection
GPI OUT n A
RX_
_
Received data (_)
No Connection
+V
n;1-4
_
No Connection
(*3)<Open collector output>
GPI OUT 5-8
GPI OUT COM
MVE-9000 IM
1-11
Download from Www.Somanuals.com. All Manuals Search And Download.
1-8. Checks on Completion of Installation
1-8-1. On-board Switches Setting and LED Functions
n
The number shown in parentheses ( ) indicates the address on the circuit board.
1. CA-54CFA board
A
B
C
D
E
E5
TP1
E2
S403
TP23
TP1301
1
2
3
4
5
1
2
3
4
F
S402
S401
E
D
C
B
A
SW1
D4
SIO-25
D409
D5
D410
SW2
DI4
DI1
D1303
D601
D602
D704
D701
D1002
D1001
D1201
D1202
CPU-DK
Module
D12
D18
D19
D14
D15
D16
D17
(COM CPU-1)
S102
S103
CPU-DR
Module
(MAIN CPU)
SW2
1
2
3
4
5
CN1003
F
SW1
D10
E3
E
D
C
B
A
D13
S101
SW1
ND101
ND102
ND901
ND902
ND1101
ND1102
S104
S901
S1101
S902
S1102
TP16 TP15 TP11 TP14
SW2
DI4
DI1
A
1
B
C
D
E
CPU-DK
Module
TP13
TP12
E2
E1
E3 E4
TP6
TP1
TP2
TP3
TP4
TP5
(COM CPU-2)
D3
D6
TP7
TP8
TP9
D7
2
DIF-130
(PC CARD)
D101
D102
D103
D104
D901
D902
D903
D904
D1101
D1102
D1103
D1104
D1
D4
D2
TP10
1
2
CN103
CN503
CN703
A
3
D100
D101
D200
5
CN401
B
E4
SG-272
E1
CN1002
A side/Component side
<LED>
D4 (A-1) : +3.3 V
D409 (A-2) : RESET status LED
System reset status indication.
+3.3 V power supply status indication.
Lit when S401 is pressed or the power voltage drops to
Lit when the +3.3 V power is supplied.
+3.3 V.
D5 (A-2) : +12 V
+12 V power supply status indication.
Lit when the +12 V power is supplied.
If this LED does not light, the fuse may have blown.
D410 (A-2) : CPU RESET status LED
CA-54CFA board reset status indication.
Lit when S402 is pressed or the power voltage drops to
+3.3 V.
D101, D102, D103, D104 (A-4), ND101 (A-3), ND102
(A-4) : MAIN CPU status LED
Main CPU status indication.
D601 (A-2) : REF EXT status LED
REF IN signal presence/absence status indication.
Lit when the REF signal is input to the REF IN connector.
Not lit when the REF signal is not input to the REF IN
connector.
MVE-9000 IM
1-12
Download from Www.Somanuals.com. All Manuals Search And Download.
D602 (A-2) : PLL LOCK status LED
REF IN signal format status indication.
Lit when the REF IN signal matches with the switcher
format setup.
<Switch>
S101 (A-3) : Mode setting switch for the main CPU
Sets the modes of the main CPU.
Default setting when shipped from the factory is all OFF.
D701 (A-2) : SBUS RX status LED
S-BUS receive status indication.
S102 (A-2) : Group ID setting switch for LAN
Sets the group ID for connecting LAN.
Lit while the data receive is in progress.
For details, refer to “MVS-8000 System Setup Manual”.
D704 (A-2) : SBUS TX status LED
S-BUS send status indication.
S103 (A-2) : Unit ID setting switch for LAN
Sets the unit ID for connecting LAN.
Lit while the data send is in progress.
For details, refer to “MVS-8000 System Setup Manual”.
D901 (A-4), D902, D903, D904 (A-5) : COM CPU-1
status LED
S104 (A-4) : Monitor reset switch for the main
CPU
COM CPU-1 status indication.
Pressing this switch resets the system while maintaining
this unit through the main CPU control terminal connector.
D1001 (A-2) : COM1 100 status LED
COM CPU-1 Ethernet communication speed status
indication.
S401 (A-1) : System reset switch
Pressing this switch activates the system reset and the
system re-starts.
Lit :
100 Mb/s
Not lit : 10 Mb/s
S402 (A-1) : CA-CPU reset switch
D1002 (A-2) : COM1 ACT status LED
Pressing this switch resets the CA-54CFA board.
COM CPU-1 Ethernet communication status indication.
Lit while data send or receive is in progress.
S403 (B-1) : Switch setting the number of the
power supply units
D1101, D1102, D1103, D1104 (A-5) : COM CPU-2
status LED
Setting switch for the number of the power supply units
that is required for this unit.
COM CPU-2 status indication.
Do not change the settings.
By the default setting when shipped from the factory, the
bit 1 and 2 are set to ON and the bit 3 and 4 are set to OFF.
D1201 (A-2) : COM2 ACT status LED
COM CPU-2 Ethernet communication status indication.
Lit while data send or receive is in progress.
S901 (A-4) : Monitor reset switch for the COM CPU-1
Pressing this switch resets the system while maintaining
this unit through the COM CPU-1 control terminal.
D1202 (A-2) : COM2 100 status LED
COM CPU-2 Ethernet communication speed status
indication.
S902 (A-4) : Modes setting switch for the COM CPU-1
Sets the modes of the COM CPU-1.
Lit :
100 Mb/s
Not lit : 10 Mb/s
Default setting when shipped from the factory is all OFF.
D1303 (A-2) : +5 V
+5 V power supply status indication.
Lit when the +5 V power is supplied.
S1101 (A-4) : Monitor reset switch for the COM CPU-2
Pressing this switch resets the system while maintaining
this unit through the COM CPU-2 control terminal.
ND901, ND902 (A-4) : COM CPU-1 status LED
COM CPU-1 status indication.
S1102 (A-4) : Modes setting switch for the COM
CPU-2
Sets the modes of the COM CPU-2.
Default setting when shipped from the factory is all OFF.
ND1101, ND1102 (A-4) : COM CPU-2 status LED
COM CPU-2 status indication.
MVE-9000 IM
1-13
Download from Www.Somanuals.com. All Manuals Search And Download.
<Connector>
<LED on the CPU-DR module> : Main CPU
D10 (green) (A-1) : RUN status LED
RUN status indication.
CN103 (A-4) : TERMINAL pin
This pin is connected to the main CPU control terminal
and used during maintenance.
Conforms to RS-232C.
Lit when the CPU-DR module starts operating.
D12 (green) (A-4) : CD (Card Detect) status LED
Lit when the CPU-DR module is inserted correctly into the
parent board.
CN401 (A-5) : TERMINAL pin
This pin is connected to the IEEE1394 control terminal and
used during maintenance.
Conforms to IEEE1394.
D13 (green) (A-1) : +2.5 V
Indicates the statue of the +2.5 V power that is generated
by the VCC (CORE) and supplied to the CPU-DR module.
Lit while the specified power is turned on.
CN503 (A-5) : TERMINAL pin
This pin is connected to the COM CPU-1 control terminal
and used during maintenance.
Conforms to RS-232C.
D14, D15, D16, D17 (A-3) (green) : STATUS1 to
STATUS4 status LED
CN703 (A-5) : TERMINAL pin
This pin is connected to the COM CPU-2 control terminal
and used during maintenance.
Used for maintenance purpose. Only the STATUS1 LED is
lit in normal operation.
Conforms to RS-232C.
D18 (green) (A-4) : +3.3 V
Indicates the statue of the VCC (I/O) power that is sup-
CN1002 (A-5) : TERMINAL pin
This pin is connected to the S-BUS CPU control terminal
and used during maintenance.
plied to the CPU-DR module.
Lit while the specified power is turned on.
Conforms to RS-232C.
D19 (green) (A-4) : CORE status LED
Indicates the statue of the VCC (CORE) power that is
supplied to the CPU-DR module.
CN1003 (A-3) : ISP common connector
Used only for production in the assembly factory. Used for
program writing into the JTAG device with ISP.
Lit while the specified power is turned on.
<Switch on the CPU-DR module> : Main CPU
SW1 (A-1) : RESET switch
<TEST terminal>
E1 (E-5), E2 (E-1), E3 (C-3), E4 (A-5), E5 (A-1) :
GND terminal
Pressing this switch resets the CPU-DR module.
n
Use this terminal as the earth point for measuring the
respective check terminals.
In some machines in which the CPU-DR module is
installed, the system reset may be activated.
TP1 (A-1) : +3.3 V check terminal
SW2 (A-2) : MODE switch
+3.3 V measuring terminal.
8-pin DIP switch
Used only for production in the assembly factory. All
switches are set to OFF for normal operation.
Default setting when shipped from the factory is all OFF.
TP23 (B-1) : +12 V check terminal
+12 V measuring terminal.
TP1301 (A-1) : +5 V check terminal
+5 V measuring terminal.
MVE-9000 IM
1-14
Download from Www.Somanuals.com. All Manuals Search And Download.
<LED on the CPU-DK module> : COM CPU-1
: COM CPU-2
<LED on the DIF-130 board> : PC card
D1 (A-1) : DETECT A
DI1 (green) (B-5) : CD (Card Detect) status LED
Lit when the CPU-DK module is inserted correctly to the
parent board.
Lit when the socket “A” is inserted correctly.
D2 (A-1) : DETECT B
Lit when the socket “B” is inserted correctly.
DI2 (green) (F-3) : RUN status LED
Lit when the CPU-DK module starts operating.
D3 (A-1) : +3.3 V
+3.3 V power supply status indication.
Lit when +3.3 V power is supplied.
DI3 (F-3), DI6 (F-3), DI7 (F-3), DI8 (F-4) (green) :
STATUS1 to STATUS4 LED
Used for maintenance purpose. Only the STATUS1 LED is
lit in normal operation.
D4 (A-1) : ACTIVE A
Lit when the socket “A” is active.
DI4 (green) (B-5) : +3.3 V
Indicates the status of the VCC (CORE) and VCC (I/O)
powers that are supplied to the CPU-DK module.
D6 (A-1) : CD (Card Detect) status LED
Lit when the DIF-130 board is inserted into the mother
board correctly.
<Switch on the CPU-DK module> : COM CPU-1
: COM CPU-2
D7 (A-1) : GPO status LED
GPO status indication.
SW1 (D-5) : RESET switch
Pressing this switch resets the CPU-DK module.
n
In some machines in which the CPU-DK module is
installed, the system reset may be activated.
< Test terminal on the DIF-130 board > : PC card
E1 (E-1), E2 (A-1), E3 (B-2), E4 (C-2) : GND terminal
Use this terminal as the earth point for measuring the
respective check terminals.
SW2 (C-5) : MODE switch
TP1 (B-3) : RST# signal check terminal
8-pin DIP switch
RST # signal measuring terminal.
Used only for production in the assembly factory. All
switches are set to OFF for normal operation.
Default setting when shipped from the factory is all OFF.
TP2 (B-3) : CLK signal check terminal
CLK signal measuring terminal.
TP3 (B-3) : FRAME signal check terminal
FRAME signal measuring terminal.
TP4 (B-3) : IRDY signal check terminal
IRDY signal measuring terminal.
TP5 (B-3) : TRDY signal check terminal
TRDY signal measuring terminal.
TP6 (C-3) : DEVSEL signal check terminal
DEVSEL signal measuring terminal.
TP7 (C-3) : STOP signal check terminal
STOP signal measuring terminal.
TP8 (C-3) : LOCK signal check terminal
LOCK signal measuring terminal.
MVE-9000 IM
1-15
Download from Www.Somanuals.com. All Manuals Search And Download.
TP9 (C-3) : PERR signal check terminal
<LED on the SG-272 board>
PERR signal measuring terminal.
D100 (B-1) : REF OK status LED
Lit while V sync of the reference input is detected.
TP10 (C-3) : SERR signal check terminal
SERR signal measuring terminal.
D101 (B-1) : REF EXT status LED
Lit while sync signal is input to the reference input.
TP11 (B-1) : PAR signal check terminal
PAR signal measuring terminal.
D200 (B-1) : LOCK status LED
Lit while the machine is locked to the reference signal.
TP12 (D-1) : INT signal check terminal
INT signal measuring terminal.
TP13 (D-1) : CBE3 signal check terminal
CBE3 signal measuring terminal.
TP14 (C-1) : CBE2 signal check terminal
CBE2 signal measuring terminal.
TP15 (B-1) : CBE1 signal check terminal
CBE1 signal measuring terminal.
TP16 (B-1) : CBE0 signal check terminal
CBE0 signal measuring terminal.
MVE-9000 IM
1-16
Download from Www.Somanuals.com. All Manuals Search And Download.
2. DVP-24A board (MKE-9040M)
A
B
C
D
E
F
G
H
1
2
TP3801
TP3802
TP3803
D3801
D3802
D3803
D13
D10
TP601
TP3804 D3804
SW1
S3801
SW2
D17
D16
D15
D14
D19
D18
D3701
D1301
CPU-DR
Module
(CPU A)
D3703
D1302
D3702
D1303
D3704
ND3802
ND3801
CN4601
S3501
CN3503
D12
3
4
S3601
CN3602
CN3502
CN4301
S3901
E501
D13
D10
SW1
SW2
D17
D504
D501
D505
D502
D503
D506
5
TP504
TP501
TP505
TP502
TP503
TP506
CPU-DR
Module
(CPU B)
D16
D15
D14
D19
D18
D3706
D3705
D12
6
7
TP3091
TP3902
TP3903
TP3904
ND3902
ND3901
D3091
D3902
D3903
D3904
TP201
E201
TP301
E301
TP202
E202
TP302
E302
TP401
E401
A side/Component side
<LED>
D501 (H-5) : +1.5 V-1
D1301 (H-2) : BUS A status LED
+1.5 V-1 power supply status indication.
Lit when CPU A accesses the FPGA.
Lit when the +1.5 V-1 power is supplied.
D1302 (H-2) : BUS B status LED
D502 (H-5) : +2.5 V-1
Lit when CPU B accesses the FPGA.
+2.5 V-1 power supply status indication.
Lit when the +2.5 V-1 power is supplied.
D1303 (H-2) : READ status LED
Lit when CPU A or B makes the read access to the FPGA.
D503 (H-5) : +3.3 V
+3.3 V power supply status indication.
Lit when the +3.3 V power is supplied.
D3701 (H-2) : BOOT DONE status LED
Lit when IC108 starts up.
D504 (H-5) : +1.5 V-2
+1.5 V-2 power supply status indication.
Lit when the +1.5 V-2 power is supplied.
D3702 (H-2) : DLKD status LED
Lit when the DLL (Delay Locked Loop) of the FPGA is
locked. If this LED does not light, the FPGA may be
defective.
D505 (H-5) : +2.5 V-2
+2.5 V-2 power supply status indication.
Lit when the +2.5 V-2 power is supplied.
D3703 (H-2) : RCB DONE status LED
Lit when configuration of FPGA is complete.
D506 (H-5) : +12 V
+12 V power supply status indication.
Lit when the +12 V power is supplied.
MVE-9000 IM
1-17
Download from Www.Somanuals.com. All Manuals Search And Download.
D3704 (H-2) : SYSTEM status LED
Lit when configuration is complete and FPGA reset is also
complete. If the LED does not light, the FPGA may be
defective.
<Switch>
S3501 (H-3) : CPU A CONFIG switch
Used for maintenance purpose.
S3601 (H-3) : CPU B CONFIG switch
D3705 (H-5) : CN EXIST status LED
Used for maintenance purpose.
CN-2357 board presence/absence status indication.
Lit on the DVP-24A board that is installed in the same slot
of CN-2357 board when CN-2357 board is present.
S3801 (H-2) : SETUP A switch
Used for maintenance purpose.
D3706 (H-6) : CN POWER status LED
The CN-2357 board power status indication.
Lit on the DVP-24A board that is installed in the same slot
of CN-2357 board while the power supply inside the CN-
2357 board is activated.
S3901 (H-5) : SETUP B switch
Used for maintenance purpose.
<Connector>
CN3502 (H-4) : USB A terminal
Used for maintenance purpose.
D3801 (H-1) : DBG 7 A status LED
Used for design purpose.
CN3503 (H-3) : COM A terminal
Used for maintenance purpose.
D3802 (H-1) : DBG 6 A status LED
Used for design purpose.
CN3602 (H-3) : COM B terminal
Used for maintenance purpose.
D3803 (H-1) : DBG 5 A status LED
Used for design purpose.
CN4301 (H-4) : EPR terminal
Used for maintenance purpose.
D3804 (H-1) : DBG 4 A status LED
Used for design purpose.
CN4601 (H-3) : IEEE1394 terminal
Used for maintenance purpose.
D3901 (H-6) : DBG 7 B status LED
Used for design purpose.
<TEST terminal>
E201 (B-7), E202 (D-7), E301 (C-7), E302 (F-7),
E401 (G-7), E501 (H-5) : GND terminal
Use this terminal as the earth point for measuring the
respective check terminals.
D3902 (H-6) : DBG 6 B status LED
Used for design purpose.
D3903 (H-7) : DBG 5 B status LED
Used for design purpose.
TP201 (B-7) : +1.5 V-1/20 A check terminal
+1.5 V-1/20 A measuring terminal.
D3904 (H-7) : DBG 4 B status LED
Used for design purpose.
TP202 (D-7) : +1.5 V-2/20 A check terminal
+1.5 V-2/20 A measuring terminal.
ND3801 (H-2), ND3802 (H-2) : STATUS A LED
DVP-24A board CPU_A status indication.
TP301 (C-7) : +2.5 V-1/20 A check terminal
+2.5 V-1/20 A measuring terminal.
ND3901 (H-6), ND3902 (H-6) : STATUS B LED
DVP-24A board CPU_B status indication.
TP302 (F-7) : +2.5 V-2/20 A check terminal
+2.5 V-2/20 A measuring terminal.
TP401 (G-7) : +3.3 V/20 A check terminal
+3.3 V/20 A measuring terminal.
MVE-9000 IM
1-18
Download from Www.Somanuals.com. All Manuals Search And Download.
<LEDs on the CPU-DR module> (G-2), (G-5)
Refer to <LED on the CPU-DR module> in “1. CA-
54CFA Board”.
TP501 (H-5) : +1.5 V-1 check terminal
+1.5 V-1 measuring terminal.
TP502 (H-5) : +2.5 V-1 check terminal
<Switches on the CPU-DR module> (G-2), (G-5)
Refer to <Switches on the CPU-DR module> in “1. CA-
54CFA Board”.
+2.5 V-1 measuring terminal.
TP503 (H-5) : +3.3 V check terminal
+3.3 V measuring terminal.
TP504 (H-5) : +1.5 V-2 check terminal
+1.5 V-2 measuring terminal.
TP505 (H-5) : +2.5 V-2 check terminal
+2.5 V-2 measuring terminal.
TP506 (H-5) : +12 V check terminal
+12 V measuring terminal.
TP601 (A-1) : CK (clock for video signal) terminal
Used when checking the clock for video signal.
TP3801 (H-1) : DBG 3 A check terminal
Used for design purpose.
TP3802 (H-1) : DBG 2 A check terminal
Used for design purpose.
TP3803 (H-1) : DBG 1 A check terminal
Used for design purpose.
TP3804 (H-1) : DBG 0 A check terminal
Used for design purpose.
TP3901 (H-6) : DBG 3 B check terminal
Used for design purpose.
TP3902 (H-6) : DBG 2 B check terminal
Used for design purpose.
TP3903 (H-6) : DBG 1 B check terminal
Used for design purpose.
TP3904 (H-6) : DBG 0 B check terminal
Used for design purpose.
MVE-9000 IM
1-19
Download from Www.Somanuals.com. All Manuals Search And Download.
3. VIF-28 board
A
1
B
C
D
E
F
G
H
J
K
L
M
N
P
R
E623
E605
2
3
4
5
6
7
TP301
TP401
TP501
D601
TP201
TP601
TP605
TP604
D605
D604
E601
E611
E609
D602
TP602
D603
TP603
E608
TP3105
TP3104
TP3102
TP3103
TP1401
TP1201 TP1801
TP1101
TP1601
E610
E625
TP1001
E626 TP801
E622
TP1301
TP1701
TP1501
TP701
TP901
CN3202
E606
8
CN3203
S3201
CN4001
D3304
D3302
D3303
D3301
E604
9
D3401
D3402
D3403
D3404
D12
10
11
12
13
D18
D19
D14
D15
D16
D17
E627
ND3401
ND3402
CPU-DR
Module
E607
SW2
SW1
D10
D13
TP3401 TP3404 TP3402
TP3403
S3401
A side/Component side
D605 (A-4) : +3.3 V
<LED>
+3.3 V power supply status indication.
D601 (A-3) : +12 V
Lit when the +3.3 V power is supplied.
+12 V power supply status indication.
Lit when the +12 V power is supplied.
D3301 (A-10) : BOOT DONE status LED
If this LED does not light, the fuse may have blown.
Lit when IC3301 starts up.
D602 (A-4) : +1.8 V
D3302 (A-9) : DLKD status LED
Lit when the DLL of the FPGA is locked. If this LED does
not light, the FPGA may be defective.
+1.8 V power supply status indication.
Lit when the +1.8 V power is supplied.
D603 (A-5) : +1.5 V
D3303 (A-10) : RCB DONE status LED
Lit when configuration of FPGA is complete.
+1.5 V power supply status indication.
Lit when the +1.5 V power is supplied.
D3304 (A-9) : SYSTEM status LED
Lit when configuration is complete and FPGA reset is also
complete. If the LED does not light, the FPGA may be
defective.
D604 (A-4) : +2.5 V
+2.5 V power supply status indication.
Lit when the +2.5 V power is supplied.
MVE-9000 IM
1-20
Download from Www.Somanuals.com. All Manuals Search And Download.
D3401, D3402, D3403, D3404 (A-10) : DBG7-4
status LED
Used for design purpose.
TP701 (G-7), TP801 (G-7), TP901 (E-7), TP1001
(E-7), TP1101 (K-6), TP1201 (K-6), TP1301 (J-6),
TP1401 (H-6), TP1501 (N-6), TP1601 (N-6), TP1701
(M-6), TP1801 (M-6) : ERR terminal
ND3401 (A-10), ND3402 (A-11) : STATUS LED
Used for design purpose.
VIF-28 board CPU status indication.
TP3102 (C-6) : CKX (control timing) signal check
<Switches>
terminal
S3201 (A-8) : CPU CONFIG switch
Used for maintenance purpose.
Use this terminal to check the CKX signal supplied from
mother board.
S3401 (A-10) : SETUP switch
Used for maintenance purpose.
TP3103 (C-6) : FD signal check terminal
Use this terminal to check the FD signal supplied from
mother board.
<Connectors>
CN3202 (A-7) : USB terminal
Used for debugging.
TP3104 (C-6) : HD (horizontal sync) signal check
terminal
Use this terminal to check the HD signal supplied from
mother board.
CN3203 (A-8) : TERMINAL pin
This pin is connected to the sub CPU control terminal and
used during maintenance. Conforms to RS-232C.
TP3105 (C-5) : VD (vertical sync) signal check
terminal
Use this terminal to check the VD signal supplied from
mother board.
CN4001 (A-9) : ISP common connector
Used only for production in the assembly factory. Used for
program writing into the JTAG device with ISP.
TP3401 (A-9), TP3402 (A-9), TP3403 (A-10),
TP3404 (A-9) : DBG3-0 check terminal
Used for design purpose.
<TEST terminals>
E601 (H-4), E604 (C-9), E605 (N-2), E606 (C-7),
E607 (A-11), E608 (B-5), E609 (L-4), E610 (N-6),
E611 (E-4), E622 (F-7), E623 (A-2), E625 (J-6),
E626 (F-7), E627 (F-10) : GND terminals
Use these terminals as the earth point for measuring the
respective check terminals.
<LEDs on the CPU-DR module> (C-11)
Refer to <LED on the CPU-DR module> in “1. CA-
54CFA Board”.
<Switches on the CPU-DR module> (C-11)
Refer to <Switches on the CPU-DR module> in “1. CA-
54CFA Board”.
TP201 (C-3), TP603 (A-5) : +1.5 V check terminal
+1.5 V measuring terminal.
TP301 (E-3), TP602 (A-5) : +1.8 V check terminal
+1.8 V measuring terminal.
TP401 (G-3), TP604 (A-4) : +2.5 V check terminal
+2.5 V measuring terminal.
TP501 (J-3), TP605 (A-4) : +3.3 V check terminal
+3.3 V measuring terminal.
TP601 (A-4) : +12 V check terminal
+12 V measuring terminal.
MVE-9000 IM
1-21
Download from Www.Somanuals.com. All Manuals Search And Download.
1-9. System Connection
Connection Example of the MVS-8000 System (MKE-9020M Installed)
Reference video signal b)
Ethernet switch a)
Ethernet switch a)
DATA
REMOTE 1-4
MVE-9000-C DME
Processor Pack
CONTROL
BVE-9100 Editing
Control System
Reference
video signal b)
CTRL
DATA CTRL REMOTE 1
PERIPH
REMOTE
DATA
MKS-8010 System
Control Unit
Reference video
signal b)
BKS-R Series
HDS-X Series
DCU-8000 Device Control Unit Pack
PERIPH
Reference
video signal b)
VTR
Audio Mixer
DDR
MVS-8400/8300/8200 Switcher Processor Pack
Cross cable
Cable with BNC
connectors
a) It is recommended that the CTRL and DATA
LAN networks be configured by connecting
separate Ethernet switches for each LAN.
However, it is also possible to make connections
for both LANs on a single Ethernet switch.
b) Terminate with the supplied 75 Z terminators.
Terminators are supplied in the product
package.
MVE-9000 IM
1-22
Download from Www.Somanuals.com. All Manuals Search And Download.
Flow of Video Signals (MKE-9020M Installed)
The figure below shows the flow of video signals in a MVS-8000 system.
MVE-9000-C DME Processor Pack
MONI OUT
SWITCHER A
SWITCHER B
Monitor
EXT IN
100 to 240 V AC power supply a)
Reference video signal c)
Reference video signal c)
DME 1B
100 to 240 V AC power
supply b)
100 to 240 V AC power
supply b)
DME 1A
Camera,
VTR,
routing
switcher
PRIMARY INPUTS
1-68
OUTPUTS 1 48
-
VTR
MONITOR OUTPUTS
1-8
Monitor
PRIMARY INPUTS
69-80
MVS-8400/8300/8200
Switcher Processor Pack
100 to 240 V AC power supply b)
100 to 240 V AC power supply b)
Video input signal
Video output signal
Cable with 68-pin connectors
Video/key signal
AC power supply
a) For the AC power cord of this unit, refer to Section 1-2 “Power
Supply” in this manual.
c) Terminate with the supplied 75 Z terminators. Terminators are
supplied in the product package.
b) For the AC power cord of the MVS-8000, refer to Section 1-2
“Power Supply” in the MVS-8400/8300/8200 Installation Manual.
MVE-9000 IM
1-23
Download from Www.Somanuals.com. All Manuals Search And Download.
Connection Example of the MVS-8000 System (MKE-9021M Installed)
Reference video signal b)
Ethernet switch a)
Ethernet switch a)
DATA
REMOTE 1-4
MVE-9000-C DME
Processor Pack
CONTROL
BVE-9100 Editing
Control System
Reference
video signal b)
CTRL
DATA CTRL REMOTE 1
PERIPH
REMOTE
DATA
MKS-8010 System
Control Unit
Reference video signal b)
BKS-R Series
HDS-X Series
DCU-8000 Device Control Unit Pack
PERIPH
Reference
video signal b)
VTR
Audio Mixer
DDR
MVS-8400/8300/8200 Switcher Processor Pack
Cross cable
Cable with BNC
connectors
a) It is recommended that the CTRL and DATA
LAN networks be configured by connecting
separate Ethernet switches for each LAN.
However, it is also possible to make connections
for both LANs on a single Ethernet switch.
b) Terminate with the supplied 75 Z terminators.
Terminators are supplied in the product
package.
MVE-9000 IM
1-24
Download from Www.Somanuals.com. All Manuals Search And Download.
Flow of Video Signals (MKE-9021M Installed)
The figure below shows the flow of video signals in a MVS-8000 system.
MVE-9000-C DME Processor Pack
V. K OUT
V. K IN/EXT IN
100 to 240 V AC power
supply a)
MONI OUT
Reference video signal c)
Monitor
Reference video signal c)
100 to 240 V AC power
supply b)
100 to 240 V AC power
supply b)
PRIMARY INPUTS
68
1
-
OUTPUTS
1-48
MONITOR OUTPUTS
1-8
Monitor
MVS-8400/8300/8200
Switcher Processor Pack
100 to 240 V AC power supply b)
100 to 240 V AC power supply b)
Video input signal
Video output signal
Video/key signal
AC power supply
a) For the AC power cord of this unit, refer to Section 1-2 “Power
Supply” in this manual.
c) Terminate with the supplied 75 Z terminators. Terminators are
supplied in the product package.
b) For the AC power cord of the MVS-8000, refer to Section 1-2
“Power Supply” in the MVS-8400/8300/8200 Installation Manual.
MVE-9000 IM
1-25
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Section 2
Service Overview
2-1. Troubleshooting
The main power cannot be turned on. (Indicator does not light green.)
Flow1
The main power of the MVE-9000 cannot be turned on.
(Indicator does not light green.)
YES
NO
Is the POWER switch A of the MVE-9000 turned ON?
YES
Set it to ON.
NO
Is the power cord of the MVE-9000 connected correctly?
YES
Connect it correctly.
The power supply unit is probably defective.
The monitor picture is not displayed correctly.
Flow2
The monitor picture is not displayed correctly even
though the main power of the MVE-9000 is turned on.
YES
NO
Insert the plug-in boards into the correct slots.
(Refer to the MVE-9000-C Maintenance Manual.)
Are the plug-in boards inserted into their correct
slots?
YES
Insert the option boards into the correct slots
respectively. (Refer to Section 1-4.)
Are the option boards inserted into their correct
slots?
NO
NO
YES
Connect the input and output cables and equipment
correctly.
Are the input and output cables connected correctly?
YES
NO Install the software correctly.
Is the software installed correctly?
YES
(Refer to the User’s Guide.)
NO Start up the system in the Factory Set mode and
check to see.
Is the system set in the Factory Set mode?
YES
* About the Factory Set, refer to Chapter “Engineering Setup”
of the MVS-8000 System User’s Guide.
The MVE-9000 is probably defective.
MVE-9000 IM
2-1
Download from Www.Somanuals.com. All Manuals Search And Download.
2-2. Periodic Inspection and Maintenance
2-2-1. Cleaning
2-3. About the Data Backup Capacitor
A large capacitor is installed on the CA-54CFA board in
order to backup the memory storing the setup and other
data in the MVE-9000. Leave the main power of the MVE-
9000 turned on for an hour or longer in order to charge this
capacitor. The data is backed up for about a week when the
capacitor is fully charged under normal operating tempera-
ture.
Front panel
The filter on the rear of the front panel can easily accumulate
the dust. Be sure to remove dust by cleaning as follows.
1. Remove the front panel. (Refer to Section 1-4-1.)
2. Remove the dust accumulated on the filter with a
vacuum cleaner.
n
Cleaning the filter by washing in water is recommend-
ed when there is a heavy accumulation of dust.
Be sure to dry the filter completely after it has been
washed.
Front panel
Filter
Fan
If dust has accumulated in the intake of the fan, air is
prevented from flowing smoothly and this may result in a
temperature rise inside the machine. This may have an
adverse effect on performance and the life of the machine.
Cleaning of the fan every month is recommended.
Contact your local Sony Sales Office/Service Center for
information on cleaning the fan.
Fan
Fan
MVE-9000 IM
2-2
Download from Www.Somanuals.com. All Manuals Search And Download.
The material contained in this manual consists of
information that is the property of Sony Corporation.
Sony Corporation expressly prohibits the duplication of
any portion of this manual or the use thereof for any
purpose other than the operation or maintenance of the
equipment described in this manual without the express
written permission of Sony Corporation.
Le matériel contenu dans ce manuel consiste en
informations qui sont la propriété de Sony Corporation.
Sony Corporation interdit formellement la copie de
quelque partie que ce soit de ce manuel ou son emploi
pour tout autre but que des opérations ou entretiens de
l’équipement à moins d’une permission écrite de Sony
Corporation.
Das in dieser Anleitung enthaltene Material besteht aus
Informationen, die Eigentum der Sony Corporation sind.
Die Sony Corporation untersagt ausdrücklich die
Vervielfältigung jeglicher Teile dieser Anleitung oder den
Gebrauch derselben für irgendeinen anderen Zweck als
die Bedienung oder Wartung der in dieser Anleitung
beschriebenen
Ausrüstung
ohne
ausdrückliche
schriftliche Erlaubnis der Sony Corporation.
MVE-9000 IM
Download from Www.Somanuals.com. All Manuals Search And Download.
Printed in Japan
2003. 4 08
©2003
Sony Corporation
MVE-9000-C (SY) E