XC-E series  
OUTLINE  
The XC-ES30/30CE, XC-ES50/50CE, XC-EI30/30CE, and XC-EI50/50CE are industrial black-and-white video camera  
modules, each using a 1/3- or 1/2-inch IT CCD. The 1/3- and 1/2-inch C mount commonly used in industrial applications  
implements compact size and lightweight. Switching of each mode on the rear panel, which has been installed from  
the XC-ST series, is followed to provide improved operability. The XC-EI series uses a CCD which is sensitive on a  
near infrared area to capture a clear image even in low-intensity illumination. As with the existing devices, the XC-  
ES30/30CE, XC-ES50/50CE, XC-EI30/30CE, and XC-EI50/50CE incorporate significant shock and vibration resistance  
to support installation on FA equipment.  
MAIN FEATURES  
1/3" and 1/2" IT CCD  
A CCD sensitive on a near infrared area is used for the XC-EI series.  
External trigger shutter function  
(XC-ES50/ES30, XC-EI50/EI30: 1/4 to 1/10,000 seconds,  
XC-ES50CE/ES30CE, XC-EI50CE/EI30CE: 1/4 to 1/8,000 seconds)  
Restart Reset (R.R) function  
Inputting HD and VD signals (2 VD or more) continuously from the outside can catch one image at arbitrary time  
and control the stored CCD.  
This function is used for long exposures and strobe with frame image output.  
Synchronization system: Internal/external HD/VD  
Inputting an HD/VD signal from the outside automatically establishes external synchronization.  
This function is effective for controlling multiple cameras efficiently from the external system.  
Setting each mode on rear panel  
The setting of each mode can be changed by the DIP switch.  
Almost all switches are located on the rear panel. This feature permits easy setting after equipment is installed.  
Compact and lightweight  
Compared to the existing devices, the size and weight are reduced widely.  
Each of the XC-ES30/30CE, XC-ES50/50CE, XC-EI30/30CE, and XC-EI50/50CE can be used in applications  
using two-piece cameras.  
C-mount  
Excellent shock and vibration resistance  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
SYSTEM CONFIGURATION  
The components making up the system based on XC-E series video camera are as follows.  
Video camera module  
Camera cables  
Camera adaptor  
DC-700/700CE  
XC-ES50/50CE  
XC-ES30/30CE  
XC-EI50/50CE  
XC-EI30/30CE  
CCXC-12P02N (2 m)  
CCXC-12P05N (5 m)  
CCXC-12P10N (10 m)  
CCXC-12P25N (25 m)  
Junction box  
JB-77  
Tripod adaptor  
VCT-333I (Isolated type)  
C-mount lenses  
VCL-08YM  
Close-up ring kit  
LO-77ERK  
VCL-12YM  
VCL-16Y-M  
VCL-25Y-M  
VCL-50Y-M  
SPECIFICATIONS COMPARISON  
XC-ST50  
XC-ES50  
1/2"IT CCD  
XC-EI50  
XC-ST30  
XC-ES30  
XC-EI30  
Image pickup device  
1/3"IT CCD  
768 (H) x494 (V)  
C mount  
768 (H) x494 (V)  
C mount  
Number of effective pixels  
Lens mount  
Scanning system  
Sensitivity  
2:1 interlaced  
2:1 interlaced  
400 lx F8  
(γ =ON, 0dB)  
400 lx F5, 6  
(γ =ON, Min Gain IR  
without IR cut filter)  
400 lx F11  
400 lx F8  
(γ =ON, 0dB)  
400 lx F8  
(γ =ON, Min Gain IR  
without IR cut filter)  
400 lx F8  
(γ =ON, Min Gain IR  
(γ =ON, Min Gain IR  
without IR cut filter)  
without IR cut filter)  
Minimum  
0.3 lx  
0.3 lx  
0.1 lx  
0.3 lx  
0.2 lx  
illuminance *  
Normal shutter  
1/100 to 1/10,000 seconds  
1/4 to 1/10,000 seconds  
1/100 to 1/10,000 seconds  
1/4 to 1/10,000 seconds  
External trigger shutter  
Dimensions  
44 (W) x29 (H) x57.5 (D) mm  
44 (W) x29 (H) x57.5 (D) mm  
29 (W) x29 (H) x32 (D) mm  
29 (W) x29 (H) x32 (D) mm  
Mass  
105 g  
50 g (approx.)  
105 g  
50 g (approx.)  
Shock resistance  
*F1.4, γ =ON, MAX GAIN  
10G (in the X, Y, and Z directions at 20 to 200 Hz)  
10G (in the X, Y, and Z directions at 20 to 200 Hz)  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
MAIN SPECIFICATIONS  
Image pickup device  
XC-ES50/50CE, XC-EI50/50CE:  
1/2-inch interline transfer CCD  
XC-ES30/30CE, XC-EI30/30CE:  
1/3-inch interline transfer CCD  
Sensitivity  
XC-ES50/50CE: 400 lx F5,6 (γ =ON, MIN Gain,  
without IR cut filter)  
XC-ES30/30CE: 400 lx F4 (γ =ON, MIN Gain,  
without IR cut filter)  
Number of effective pixels  
XC-ES50/EI50, XC-ES30/EI30:  
768 (H)x494 (V)  
XC-EI50/50CE: 400 lx F11 (γ =OFF, MIN Gain,  
without IR cut filter)  
XC-EI30/30CE: 400 lx F8 (γ =ON, MIN Gain,  
without IR cut filter)  
XC-ES50CE/EI50CE, XC-ES30CE/EI30CE:  
752 (H)x582 (V)  
S/N ratio  
60dB  
CCD horizontal driving frequency  
XC-ES50/EI50, XC-ES30/EI30:  
14.318 MHz  
Minimum illuminance  
XC-ES50/50CE, XC-ES30/30CE:  
0.3 lx (F1.4 γ =ON, MAX Gain,  
XC-ES50CE/EI50CE, XC-ES30CE/EI30CE:  
14.187 MHz  
without IR cut filter)  
XC-EI50/50CE: 0.1 lx (F1.4 γ =ON, MAX Gain,  
without IR cut filter)  
CCD vertical driving frequency  
XC-ES50/EI50, XC-ES30/EI30:  
15.734 kHz  
XC-EI30/30CE: 0.2 lx (F1.4 (γ =ON, MAX Gain,  
without IR cut filter)  
XC-ES50CE/EI50CE, XC-ES30CE/EI30CE:  
15.625 kHz  
Gain  
AGC/Manual (Can be selected using  
the switch on the rear panel.)  
ON/OFF (Can be selected  
using the switch on the rear  
panel.)  
Signal system  
Cell size  
EIA/CCIR  
Gamma correction  
XC-ES50/EI50:  
8.4 (H)x9.8 (V) µ m  
XC-ES50CE/EI50CE: 8.6 (H)x8.3 (V) µ m  
XC-ES30/EI30: 6.35 (H)x7.4 (V) µ m  
XC-ES30CE/EI30CE: 6.5 (H)x6.25 (V) µ m  
Electronic shutter  
XC-ES50/EI50, XC-ES30/EI30:  
1/100 to 1/10,000 seconds  
Lens mount  
Flange back  
C-mount  
XC-ES50CE/EI50CE, XC-ES30CE/EI30CE:  
1/120 to 1/10,000 seconds  
17.526 mm  
Synchronization system  
Internal/external  
(Selected automatically)  
External sync input/output  
External trigger shutter  
XC-ES50/EI50, XC-ES30/EI30:  
1/4 to 1/10,000 seconds  
XC-ES50CE/EI50CE, XC-ES30CE/EI30CE:  
1/4 to 1/8,000 seconds  
HD/VD (2 to 5 Vp-p)  
Automatically selected according  
Set using the DIP switch on the rear panel, or  
*
*
to the existence of an input signal  
variable with the trigger pulse width.  
when the selection switch on the rear  
Supply voltage  
+12 VDC (+9.0V to 16V)  
panel is set to EXT.  
Power consumption  
Allowable frequency deviation of external synchronization  
± 1 %  
XC-ES30/30CE, XC-EI30/30CE:  
XC-ES50/50CE, XC-EI50/50CE:  
1.4W  
1.6W  
(in horizontal synchronous frequency)  
Operating temperature  
Storage temperature  
–5 ˚C to +45 ˚C  
–20 ˚C to +60 ˚C  
Jitter  
Within ± 50 nsec  
2:1 interlacing  
Scanning system  
Performance assurance temperature  
Non-interlacing  
0 ˚C to +30 ˚C  
(during external sync input)  
Operating humidity  
Storage humidity  
Vibration resistance  
20 to 80 % (Non-condensing)  
20 to 95 % (Non-condensing)  
10G (For 20 minutes in the X, Y,  
and Z directions at 20 to 200 Hz)  
Horizontal resolution  
XC-ES50/EI50, XC-ES30/EI30:  
XC-ES50CE/EI50CE, XC-ES30CE/EI30CE:  
560 TV lines  
570 TV lines  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
MAIN SPECIFICATIONS  
Shock resistance  
70G  
External synchronization for each mode  
Outside dimensions 29 (W) x 29 (H) x 32 (D) mm  
External sync  
Mode  
Internal sync  
Weight  
50 g  
HD/VD  
VS  
Standards  
UL1492, FCC Class A Digital  
Device, and CE (EN50081-2 +  
EN50082-2)  
Normal  
Normal shutter  
Other  
Restart Reset function  
Mode 1  
×
×
F
rame or field integration can be  
selected.  
Trigger signal  
generates an  
internal VD  
Conforms to new EIAJ and uses  
12-pin assignment.  
Lens mount cap (1)  
Instruction Manual (1)  
Mode 2  
×
(single) signal.  
Accessories  
×
Restart Reset  
×
: Can be used.  
×: Cannot be used.  
CONNECTION DIAGRAM  
C-mount lens  
AC  
VIDEO OUT  
VCL-08Y-M  
HD/VD  
WEN  
TRIG  
XC-ES50/50CE  
XC-ES30/30CE  
XC-EI50/50CE  
XC-EI30/30CE  
Camera adaptor  
DC-700/CE  
VCL-12Y-M  
VCL-16Y-M  
VCL-25Y-M  
(Conforms to new EIAJ and uses 12-pin assignment.)  
Camera cable  
CCXC-12P02N  
CCXC-12P05N  
CCXC-12P10N  
CCXC-12P25N  
Tripod adaptor  
VCT-333I  
DC +12 V  
VIDEO OUT  
HD/VD  
LO-77ERK  
Junction box  
JB-77  
(No trigger input terminal is provided.)  
VCL-50Y-M  
Close-up ring kit  
Note : All functions of the XC-ES50/50CE, XC-ES30/30CE, XC-EI50/50CE, XC-EI30/30CE  
cannot be used when using DC-777/CE, DC-77RR/CE, and JB-77 is used.  
Refer to the table shown below.  
XC-ES50/50CE  
XC-ES30/30CE  
XC-EI50/50CE  
XC-EI30/30CE  
JB-77  
Normal  
Normal shutter  
Restart Reset (R.R)  
Restart Reset (R.R)  
+
shutter  
: Can be used.  
×
External trigger shutter  
×: Cannot be used.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
LOCATION OF PARTS AND OPERATION  
XC-ES50/50CE . XC-ES30/30CE  
XC-EI50/50CE . XC-EI30/30CE  
1 Lens mount section (C mount)  
A commercial C-mount lens as well as a  
Sony standard lens can be used.  
2
2 Camera mounting reference hole  
(top)  
These screw holes are positionned with  
high precision related to CCD sensor.  
4
3 Camera mounting reference  
hole/Screw hole for tripod  
adaptor mounting (bottom)  
1
4 12-pin multi-connector  
DC IN/HD/VD (DC power/sync signal  
input) VIDEO OUT terminal  
5 75 termination selector switch  
2 3  
3
6 HD/VD input-output selector  
switch  
7
8
4
7 Shutter speed/mode setting DIP  
switch  
Switches 1 to 4:  
Select the shutter speed.  
Switch 5: Selects the frame or field  
integration.  
5
6
Switches 6 to 8:  
412-pin multi-connector  
External HD/VD  
synchronization  
Internal HD/VD  
synchronization  
Select the trigger shutter  
mode.  
Pin No.  
γ
1
2
GND  
+12 V  
GND  
+12 V  
Switch 9: Selects correction on/off.  
Switch 0: Selects the gain.  
3
GND  
GND  
4
VIDEO output  
GND  
VIDEO output  
GND  
8 Volume control switch  
This switch can be changed in the  
range of Switch 0 to 18 dB when the  
GAIN switch is set to “M”.  
5
6
External HD input  
Internal HD output  
Internal VD output  
GND  
7
1 External VD input  
*
*During factory setting, this switch is  
adjusted to the mechanical center.  
8
GND  
9
n
10  
11  
12  
2 WEN output  
2 WEN output  
*
*
When setting DIP switch 5 to the frame  
integration, set the volume control  
switch 8 to the MAX side from the  
mechanical center (because of CCD  
characteristics).  
TRIG input  
GND  
TRIG input  
GND  
1: An input VD signal is required when the restart/reset mode is used.  
2: A WEN output signal is valid only in the external trigger shutter mode.  
*
*
Factory-setting mode of rear panel  
Corresponding  
Factory-setting  
mode  
Switch  
No.  
5
6
7
75 termination selector switch  
ON  
HD/VD input-output selector switch  
Shutter speed/mode setting DIP switch  
Switches 1 to 4: Select the shutter speed.  
Switch 5: Selects the frame or field integration.  
Switches 6 to 8: Select the trigger shutter mode.  
Switch 9: Selects correction on/off.  
Switch 0: Selects the gain.  
EXT  
OFF  
FRAME  
Normal  
OFF  
Manual  
Mechanical  
center  
8
Volume control switch  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
PHASE CONDITIONS OF EXTERNAL  
SYNCHRONIZATION  
External synchronization for each mode  
• For normal video/normal shutter  
Continuous HD/VD signal (should conform to EIA and CCIR frequencies in the timing shown in the figure below.)  
• For Restart Reset (RR)/external trigger shutter  
Continuous HD signal. The phase between VD (reset) and HD signals is as specified in the figure below in any  
timing.  
Phase conditions  
The phase relation between external input HD and VD signals should be set as shown below with respect to the  
specified center phase.  
5
200  
EXT-VD  
ODD  
(EVEN)  
100  
200  
EVEN  
(ODD)  
EXT-HD  
455 (454)  
455 (454)  
Unit: Clock  
1 CLK = 69.84 n sec  
(XC-ES50/ES30, XC-EI50/EI30)  
70.48 n sec  
(XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)  
The operation in parentheses refers to XC-ES50CE/ES30CE and XC-EI50CE/EI30CE.  
Note  
: The synchronized VD signals are delayed for 1H at HD/VD external synchronization mode, while  
there is no VD signal delay at VS external synchronization mode.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
ELECTRONIC SHUTTER  
Two types of electronic shutter are provided “normal shutter and external trigger shutter”.  
The electronic shutter speed and type can be set using the DIP switch on the rear panel.  
DIP switch on the rear panel  
Rear panel  
DIP switch  
Switches 1 to 4:  
Selects the shutter speed.  
Switch 5:  
Selects the frame (0) or (1) field integration.  
Switches 6 to 8:  
Select the trigger shutter mode.  
Switch:  
γ
Selects correction ON/OFF  
Switches 0:  
Selects the Gain (Manual/AGC)  
Normal shutter  
This mode provides continuous video output with the electronic shutter selected by switches to clearly capture a  
high-speed moving object.  
Setting of normal shutter speed  
In the flickerless mode, the  
normal shutter speed is  
1/100 sec for  
1/8000(CCIR)  
1/10000(EIA)  
Shutter  
Off  
*
Switch  
1/125  
1/250  
1/500  
1/1000  
1/2000  
1/4000  
Flickerless  
*
0
0
0
0
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
0
1
1
2
3
4
5
6
7
8
XC-ES50/ES30 and  
XC-EI50/EI30 (EIA) and  
1/120 sec for  
XC-ES50CE/ES30 CE and  
XC-EI50CE/EI30CE (CCIR).  
Frame: 0 / Field: 1  
0
0
0
0
0
0
0
0
0
1: ON  
0: OFF  
–: Any  
: It is recommended to set DIP switch 5 for field selection. (The field selection is about two times in sensitivity as high as the frame selection.)  
Note  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
ELECTRONIC SHUTTER  
External trigger shutter  
These modes are used to capture one image (one field) per trigger pulse.  
Set DIP switches 6, 7, and 8 on the rear panel to mode 1 or 2. (Refer to the table below.)  
When the trigger pulse width is 1/3 sec or more, the output signal is switched to a normal video signal.  
There are two modes for timing in which a video signal is obtained.  
Mode 1 (Non-reset mode)  
In this mode, a video signal synchronized with a VD signal is output after a trigger pulse is input.  
A video signal is synchronized with the external VD signal when an external HD/VD signal is input.  
A video signal is synchronized with an internal VD signal when no external HD/VD signal is input.  
Mode 2 (Reset mode)  
In this mode, an internal video signal is output from a trigger pulse after a certain period of time.  
Video sync is always fixed with odd field for XC-ST70 and even field for XC-ST70CE.  
For more details of each timing chart, refer to pages 16 to 23.  
*
Setting of external trigger shutter speed  
There are two ways to set the shutter speed.  
Mode 1 (Non-reset mode)  
Switch  
1/100  
*
1/125  
1/250  
1/500  
1/1000 1/2000  
1/4000  
1/10000  
**  
1
2
3
4
5
6
7
8
9
0
1
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
0
Frame: 0 / Field: 1  
0
1
1
0
1
1
0
1
1
0
1
1
0
1
1
0
1
1
0
1
1
0
1
1
Mode 2 (Reset mode)  
The external trigger shutter speed is set to  
1/100 sec for XC-ES50/ES30,  
XC-EI50/EI30 (EIA) and 1/120 sec for  
XC-ES50CE/ES30CE,  
*
1/100  
*
Switch  
1/125  
1/250  
1/500  
1/1000 1/2000  
1/4000  
1/10000  
**  
1
1
0
0
0
0
1
0
0
1
1
0
0
0
0
1
0
1
0
1
0
0
1
1
0
1
1
1
0
0
0
1
1
2
3
4
5
6
7
8
9
0
XC-EI50CE/EI30CE (CCIR).  
The external trigger shutter speed is  
** set to 1/10000 sec for XC-ES50/ES30,  
Frame: 0 / Field: 1  
XC-EI50/EI30 (EIA) and 1/8000 sec for  
XC-ES50CE/ES30CE,  
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
0
0
1
XC-EI50CE/EI30CE (CCIR).  
1: ON  
0: OFF  
–: Any  
Using DIP switch on the rear panel  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
ELECTRONIC SHUTTER  
Using trigger pulse width  
Set DIP switches 1 to 4 on the rear panel to 0.  
An arbitrary shutter speed can be obtained by setting the trigger pulse width to the range of 2 µsec to 250  
msec.  
Mode 1  
Mode 2  
Switch  
Exposure time = Trigger pulse width + 97 µsec (EIA)  
(Non-reset mode) (Reset mode)  
120 µsec (CCIR)  
1. lt is recommended to set DIP switch 5 for field selection.  
(The field selection is about two times in sensitivity as high as the frame selection.)  
2. After a trigger pulse is input, a new trigger pulse must not be input before the video  
signal obtained by the trigger pulse has been output.  
0
0
0
0
0
0
0
0
1
2
3
4
5
6
7
8
9
0
:
Note  
Frame: 0 / Field: 1  
0
0
0
1
0
0
1
1
0
0
1: ON  
0: OFF  
Specifications of trigger pulse  
A
B
T
A: 4 to 5.0 V  
B: 0 to 1.0 V  
T: 2 µs to 1/4 s  
T: 2 µs to 1/4 s, 100 µs to 1/4 s when setting the shutter speed using DIP switch  
Input impedance: 10 kW or more  
*
The voltage and pulse width used are measured at pin 11 of a 12-pin multi-connector on the rear panel.  
*
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
ELECTRONIC SHUTTER  
When using a trigger pulse like shown below, set the TRIG polarity selector switch on the rear panel to – :  
A
B
T
A: 4.0 to 5.0 V  
B: 0 to 2.0 V  
T: 2 µs to 1/4 s, 100 µs to 1/4 s when setting the shutter speed using DIP switch  
Input impedance: 10 kor more  
*
*
The voltage and pulse width used are measured at pin 11 of a 12-pin multi-connector on the rear panel.  
Specifications of WEN (Write ENable Pulse)  
A
B
T
A: 5.0 V  
B: 0 V  
T: 15.875 ms (XC-ST70), 18.752 ms (XC-ST70CE)  
Output impedance: 10 kor more  
*
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
RESTART RESET (R.R)  
The information on one screen can be extracted at any time by inputting a restart/reset signal (HD/VD) from the  
outside. To enter this mode, set DIP switches 6, 7, and 8 on the rear panel of a camera as shown in the table below.  
The setting is especially effective for the following operation.  
Restart Reset (R.R)  
Switch  
0
0
0
0
0
1
1
1
0
0
1
2
3
4
5
6
7
8
9
0
1: ON  
0: OFF  
Long exposure  
A high-sensitivity image is obtained by extending the exposure time of the CCD when satisfactory sensitivity  
cannot be obtained under other operating conditions or when observing the trail of a moving object.  
The exposure time is determined by the VD interval (T) period between external VD pulses as follows.  
Timing and conditions  
Example 1 of Long exposure  
EXT HD  
Continuous signal: 15.734 kHz (XC-ES50/ES30, XC-EI50/XC-EI30)Allowable frequency value ±1%,  
15.625 kHz (XC-ES50CE/ES30CE, XC-EI50CE/XC-EI30CE) Allowable frequency value ±1%  
EXT VD  
VD interval(T): 262.5H or more (XC-ES50/ES30, XC-EI50/XC-EI30) and less than 1 second (Recommended),  
312.5H or more (XC-ES50CE/ES30CE, XC-EI50CE/XC-EI30CE) and less than 1 second (Recommended)  
Four or more VD pulses are required.  
T
T
T
Exposure time for Odd field  
Exposure time for Even field  
Video output  
Odd image  
Even image  
Invalid image  
Valid frame image  
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
RESTART RESET (R.R)  
Example 2 of long exposure  
EXT HD  
EXT VD  
Continuous signal: 15.734 kHz (XC-ES50/ES30, XC-EI50/XC-EI30) Allowable frequency value ±1%,  
15.625 kHz (XC-ES50CE/ES30CE, XC-EI50CE/XC-EI30CE) Allowable frequency value ±1%  
VD interval(T): 262.5H or more (XC-ES50/ES30, XC-EI50/XC-EI30) and less than 1 second (Recommended),  
312.5H or more (XC-ES50CE/ES30CE, XC-EI50CE/XC-EI30CE) and less than 1 second (Recommended)  
Four or more VD pulses are required.  
T
1/60 second  
1/60 second  
Exposure time for Odd field  
Exposure time for Even field  
Video output  
Odd image  
Even image  
Invalid image  
Valid frame image  
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
FRAME IMAGE OUTPUT WITH STROBE LIGHT  
A full frame image with vertical resolution of 485 lines (XC-ST70) or 575 lines (XC-ST70CE) can be obtained with  
a strobe light by firing the strobe when the exposure time of the two fields overlap.  
Timing and conditions  
<Timing chart by restart/reset>  
EXT HD  
Continuous signal: 15.734 kHz (XC-ES50/ES30, XC-EI50/XC-EI30)Allowable frequency value ±1%,  
15.625 kHz (XC-ES50CE/ES30CE, XC-EI50CE/XC-EI30CE) Allowable frequency value ±1%  
EXT VD  
VD : XC-ES50/ES30, XC-EI50/XC-EI30 (1/60sec), XC-ES50CE/ES30CE, XC-EI50CE/XC-EI30CE (1/50sec)  
Four or more VD pulses are required.  
Strobe light  
Exposure time for Odd field  
Exposure time for Even field  
Video output  
Odd image  
Even image  
Invalid image  
Valid frame image  
Odd and even fields are determined by the phase of the EXT HD/VD signal input from the outside.  
Avoid lighting the scene during the light-emitting inhibit zone defined below. (The field is transfered to the  
storage area of the CCD, so it can be read out.)  
Note  
: For best performance, it is recommended not to flash between VD and VD + 10H (XC-ES50/ES30, XC-EI50/EI30)/  
16H (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE).  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
(XC-ES50/EI50/ES30/EI30(EIA))  
OUTPUT WAVEFORM TIMING CHART  
Timing chart of horizontal output waveform  
HD  
91 (6.36 µs)  
40  
77  
22  
3
15  
752  
CCD  
output  
signal  
Effective total pixel 768  
Dummy  
pixel  
69.8 ns  
Optical black  
portion  
Horizontal transfer stop period  
Optical black portion  
Horizontal blanking period (11.0  
µs)  
Output video period  
Camera video  
output signal  
(Typical value)  
67 (4.68  
µs)  
752 (52.5 µs)  
21 HSYNC  
(1.47 µs) 70  
(4.89 µs)  
One horizontal scanning period (1 H)  
910 (63.56 s)  
µ
Timing chart of vertical output waveform (2:1 interlaced frame integration)  
Odd field (262.5 H)  
Even field (262.5 H)  
VD  
9 H  
253.5 H  
9 H  
253.5 H  
2 4 6 8  
1 3 5 7 9  
CCD  
output  
signal  
1
8
6
4
242.5  
2
8
6
3.5  
242.5  
Empty  
Empty  
transfer  
Optical black portion  
transfer  
Optical black portion  
Camera  
video  
output  
signal  
Vertical blanking  
period (20 H)  
Vertical blanking  
period (20 H)  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
OUTPUTWAVEFORMTIMING CHART (XC-ES50/EI50/ES30/EI30(EIA))  
Timing chart of vertical output waveform (2:1 interlaced field integration)  
Odd field (262.5 H)  
Even field (262.5 H)  
VD  
9 H  
253.5 H  
9 H  
253.5 H  
CCD  
output  
signal  
1
8
6
4
242.5  
1
8
6
3.5  
242.5  
Empty  
Empty  
transfer  
Optical black portion  
transfer  
Optical black portion  
Camera  
video  
output  
signal  
Vertical blanking  
period (20 H)  
Vertical blanking  
period (20 H)  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
OUTPUT WAVEFORM TIMING CHART (XC-ES50CE/EI50CE/ES30CE/EI30CE (CCIR))  
Timing chart of horizontal output waveform  
HD  
98  
(6.91 µs)  
40  
91  
22  
3
15  
736  
CCD  
output  
signal  
Effective total pixel 752  
Output video period  
Dummy  
pixel  
70.5 ns  
Optical black  
portion  
Horizontal transfer stop period  
Optical black portion  
Horizontal blanking period (12.1 µs)  
Camera video  
output signal  
(Typical value)  
81 (5.71 µs)  
736 (51.9 µs)  
21 HSYNC  
s) 70  
(4.93  
(1.48  
µ
µ
s)  
One horizontal scanning period (1 H)  
908 (64.0 µs)  
Timing chart of vertical output waveform (2:1 interlaced frame integration)  
Odd field (312.5 H)  
Even field (312.5 H)  
VD  
7.5 H  
305 H  
7.5 H  
305 H  
1 3 5 7 9  
2 4 6 8  
CCD  
output  
signal  
287.5  
287.5  
1
14  
6
3.5  
2
14  
6
3
Empty  
Empty  
transfer  
Optical black portion  
transfer  
Optical black portion  
Camera  
video  
output  
signal  
Vertical blanking  
period (25 H)  
Vertical blanking  
period (25 H)  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
U
T
PU
T
W
A
V
E
F
O
R
T
IMING CHART (XC-ES50CE/EI50CE/ES30CE/EI30CE (CCIR))  
Timing chart of vertical output waveform (2:1 interlaced field integration)  
Odd field (312.5 H)  
Even field (312.5 H)  
VD  
7.5 H  
305 H  
7.5 H  
305 H  
CCD  
output  
signal  
287.5  
287.5  
1
14  
6
3.5  
1
14  
6
3
Empty  
Empty  
transfer  
Optical black portion  
transfer  
Optical black portion  
Camera  
video  
output  
signal  
Vertical blanking  
period (25 H)  
Vertical blanking  
period (25 H)  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
SENSOR READ CLOCK TIMING CHART  
XC-ES30  
HD  
V1  
V2  
2.5  
Odd Field  
V3  
V4  
1.6  
2.5 2.5 2.5  
40.4  
0.2  
V1  
V2  
Even Field  
V3  
V4  
Unit : µs  
XC-ES30CE  
HD  
V1  
V2  
2.5  
Odd Field  
V3  
V4  
1.6  
2.5 2.5 2.5  
41.6  
0.2  
V1  
V2  
Even Field  
V3  
V4  
Unit : µs  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
SENSOR READ CLOCK TIMING CHART  
XC-ES50  
V1  
V2  
2.5  
Odd Field  
V3  
V4  
1.6  
2.5 2.5 2.5  
33.5  
0.2  
V1  
V2  
Even Field  
V3  
V4  
Unit : µs  
XC-ES50CE  
V1  
V2  
2.5  
Odd Field  
V3  
V4  
1.5  
2.6 2.5 2.5  
33.6  
0.2  
V1  
V2  
Even Field  
V3  
V4  
Unit : µs  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
SENSOR READ CLOCK TIMING CHART  
XC-EI30  
V1  
V2  
2.5  
Odd Field  
V3  
V4  
1.6  
2.5 2.5 2.5  
33.5  
0.2  
V1  
V2  
Even Field  
V3  
V4  
Unit : µs  
XC-EI30CE  
V1  
V2  
2.6  
Odd Field  
V3  
V4  
1.5  
2.6 2.6 2.6  
33.6  
0.2  
V1  
V2  
Even Field  
V3  
V4  
Unit : µs  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
SENSOR READ CLOCK TIMING CHART  
XC-EI50  
V1  
V2  
2.5  
Odd Field  
V3  
V4  
1.6  
2.5 2.5 2.5  
33.5  
0.2  
V1  
V2  
Even Field  
V3  
V4  
Unit : µs  
XC-EI50CE  
V1  
V2  
2.5  
Odd Field  
V3  
V4  
1.5  
2.6 2.5 2.5  
33.6  
0.2  
V1  
V2  
Even Field  
V3  
V4  
Unit : µs  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1  
(NON-RESET MODE)  
For setting the shutter speed using TRG width  
HD/VD input  
Mode transition state  
External input  
inhibition area  
(50 ms)  
External trigger  
shutter operation  
3
External trigger shutter operation  
*
Normal operation  
Trigger  
1
2
3
1
*
Trigger  
3
*
2
*
Exposure  
time Te  
2
2
*
Exposure time Te  
*
Exposure time Te  
1
1
*
External HD  
External VD  
*
(
Continuous  
VD)  
4
10 µs or more  
*
T : T = Under –65 us to +10 µs  
4
*
T : T = Under –65 µs to +10 µs  
EXT-VD  
+10 µs  
–65 µs  
1
2
3
Video out  
WEN  
5
*
250H (XC-ES50/ES30, XC-EI50/EI30)  
293H (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)  
TRG  
EXT-VD  
EXT-VD  
65 µs  
10 µs  
Continuous HD/VD input  
1: This is a signal input from the outside. Be sure to input both HD and VD signals in this case.  
*
*
2: Exposure time Te Te = Trigger width + 97 µs (XC-ES50/ES30, XC-EI50/EI30),  
Te = Trigger width + 120 µs (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)  
(The trigger width should be between 2 µs and 1/4 s)  
3: The normal operation state is engaged when the trigger high period exceeds 1/3sec.The external trigger  
shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the falling  
edge of a trigger pulse and the subsequent 50 ms period is an external trigger input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
*
*
*
4: In all cases the WEN signal indicates when a valid image is available. Normally, an image is output after  
the external falling edge. If the falling edge of the trigger is very close to the falling edge of the external VD,  
there may be a delay of 1VD in the output. The period of uncertainty is when the falling edge of VD is  
between 65 µs before or 10 µs after the falling edge of the trigger.  
5: When the external trigger shutter mode changes into the normal operation mode, one WEN signal is  
output.  
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)  
For setting the shutter speed using TRG width  
HD/VD input  
Mode transition state  
External input  
External trigger  
shutter operation  
inhibition area  
(50 ms)  
3
External trigger shutter operation  
*
Normal operation  
Trigger  
1
2
1
*
Trigger  
3
*
2
*
Exposure  
time Te  
2
*
Exposure time Te  
1
1
*
External HD  
*
External VD  
(Single VD)  
4
min 10 µs  
*
T : T = 10 µs to 100 ms  
1
2
Video out  
WEN  
5
*
250H  
250H  
250H  
(XC-ES50/ES30,  
XC-EI50/EI30)  
(XC-ES50/ES30,  
XC-EI50/EI30)  
(XC-ES50/ES30,  
XC-EI50/EI30)  
293H  
293H  
293H  
(XC-ES50CE/ES30CE, (XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE) XC-EI50CE/EI30CE)  
(XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE)  
Continuous HD input and single VD input  
1: This is a signal input from the outside. Be sure to input both HD and VD signals in this case. Make the  
*
*
phase of the VD signal coincide with the falling edge of the HD signal during input operation.  
2: Exposure time Te Te = Trigger width + 97 µs (XC-ES50/ES30, XC-EI50/EI30),  
Te = Trigger width + 120 µs (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)  
(The trigger width should be between 2 µs and 1/4 s)  
3: The normal operation state is engaged when the trigger high period exceeds 1/3 sec.After that the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external trigger input inhibition area.  
During the trigger inhibit period, an input trigger may be missed.  
*
*
*
4: Be sure to input an external VD signal between 10 µs and 75 ms from the falling edge of a trigger pulse (as  
shown by 1 and 2 in the figure). For the input (except described above), the operation cannot be ensured.  
If the external VD signal is not input under the prescribed conditions, the normal operation is engaged  
several V after a change in input operation under the prescribed conditions.  
5: When the external trigger shutter mode changes into the normal operation mode, one WEN signal is  
output.  
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)  
For setting the shutter speed using TRG width  
No HD/VD input (Internal synchronization)  
Mode transition state  
External input  
inhibition area  
(50 ms)  
External trigger  
shutter operation  
3
External trigger shutter operation  
*
Normal operation  
1
2
3
1
4
*
Trigger  
3
*
Trigger  
2
2
2
*
Exposure  
time Te  
*
Exposure time Te  
*
Exposure time Te  
*
Interrnal VD  
5
5
*
T : T = 10 µs or more  
*
T : T = Under 10 µs  
1
2
3
Video out  
WEN  
6
*
250H (XC-ES50/ES30, XC-EI50/EI30)  
293H (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)  
1: This is a signal input from the outside.  
*
*
2: Exposure time Te Te = Trigger width + 97 µs (XC-ES50/ES30, XC-EI50/EI30),  
Te = Trigger width + 120 µs (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)  
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
*
4: An internal VD signal is output by setting the INT/EXT switch on the rear panel to INT.  
*
*
5: During external trigger shutter operation, an image is output when an internal VD signal falls after a trigger  
pulse falls (as shown by 1 and 2 in the figure). However, if the time (T in the figure) between the falling  
edges of a trigger pulse and internal VD signal is under 10 µs, an image is output when the internal VD  
signal or the next internal VD signal falls (as shown by 3 in the figure). (In this case, an image is output  
when the next internal VD signal falls.) An image and WEN signal are always output together. For more  
details, refer to the WEN signal. (The falling edge of an internal VD signal is the same in phase as the  
beginning of an equalizing pulse in a SYNC V area.)  
6: When the external trigger shutter mode changes into the normal operation mode, one WEN signal is  
output.  
*
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)  
For setting the shutter speed using DIP switch  
HD/VD input  
Continuous HD/VD input  
Mode transition state  
External input  
External trigger  
shutter operation  
inhibition area  
(50 ms)  
3
3
External trigger shutter operation  
*
Normal operation  
Trigger  
1
2
3
1
*
Trigger  
*
2
*
Exposure  
time Te  
2
2
*
Exposure time Te  
*
Exposure time Te  
1
1
*
External HD  
*
External VD  
(Continuous  
VD)  
4
4
4
*
T : T = Under 10 ms  
*
T : T = 10 ms or more  
*
T : T = 10 ms or  
more  
1
2
3
Video out  
WEN  
250H  
250H  
(XC-ES50/ES30,  
XC-EI50/EI30)  
(XC-ES50/ES30,  
XC-EI50/EI30)  
293H  
293H  
(XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE)  
(XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE)  
1: This is a signal input from the outside.The period of a continuous VD signal is prescribed as one field. Be  
sure to input both HD and VD signals.  
*
2: As shown in the table on page 7, exposure time Te is determined by the setting of a DIP switch.  
*
*
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
4: An image is output when an external VD signal falls 10 ms or more after a trigger pulse rises (shown by 2  
and 3 in the figure). If the time (T in the figure) between the falling edges of a trigger pulse and external  
VD signal is under 10 ms, an image is output when the external VD signal or the next external VD signal  
falls (as shown by 1 in the figure). (In this case, an image is output when the next external VD signal falls.)  
An image and WEN signal are always output together. For more details, refer to the WEN signal.  
*
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)  
For setting the shutter speed using DIP switch  
HD/VD input  
Continuous HD input and single VD input  
Mode transition state  
External input  
inhibition area  
(50 ms)  
External trigger  
shutter operation  
3
External trigger shutter operation  
*
Normal operation  
Trigger  
1
2
1
*
Trigger  
3
*
2
*
Exposure  
time Te  
2
*
Exposure time Te  
1
1
*
External HD  
*
External VD  
(Single VD)  
min. 10 ms  
4
*
T : T = 10 ms to 110 ms  
1
2
Video out  
WEN  
250H  
250H  
(XC-ES50/ES30,  
XC-EI50/EI30)  
(XC-ES50/ES30,  
XC-EI50/EI30)  
293H  
293H  
(XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE)  
(XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE)  
1: This is a signal input from the outside. Be sure to input both HD andVD signals. Make the phase of theVD  
signal coincide with the falling edge of the HD signal.  
*
2: As shown in the table on page 7, exposure time Te is determined by the setting of a DIP switch.  
*
*
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
4: Be sure to input an external VD signal for 10 ms to 75 ms from the rising edge of a trigger pulse (as shown  
by 1 and 2 in the figure). For the input except described above, the operation cannot be ensured. If the  
external VD signal is not input under the prescribed conditions, the normal operation is engaged several V  
after a change in input operation under the prescribed conditions.  
*
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 1 (NON-RESET MODE)  
For setting the shutter speed using DIP switch  
No HD/VD input (Internal synchronization)  
Mode transition state  
External input  
External trigger  
shutter operation  
inhibition area  
(50 ms)  
3
External trigger shutter operation  
*
Normal operation  
Trigger  
1
2
3
1
4
*
Trigger  
3
*
2
2
2
*
Exposure time Te  
*
Exposure time Te  
*
Exposure  
time Te  
*
Interrnal VD  
5
*
T : T = 10 ms or  
more  
5
5
*
T : T = 10 ms or more  
*
T : T = Under 10 ms  
1
2
3
Video out  
WEN  
250H  
250H  
(XC-ES50/ES30,  
XC-EI50/EI30)  
(XC-ES50/ES30,  
XC-EI50/EI30)  
293H  
293H  
(XC-ES50CE/ES30CE, (XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE) XC-EI50CE/EI30CE)  
1: This is a signal input from the outside.  
*
*
*
2: As shown in the table on page 7, exposure time Te is determined by the setting of a DIP switch.  
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
4: An internal VD signal is output by setting the INT/EXT switch on the rear panel to INT.  
*
*
5: An image is output when an internal VD signal falls 10 ms or more after a trigger pulse rises (as shown by  
2 and 3 in the figure). If the time (T in the figure) between the falling edges of a trigger pulse and internal  
VD signal is under 10 ms, an image is output when the internalVD signal or the nextinternalVD signal falls  
(as shown by 1 in the figure). In this case, an image is output when the next internal VD signal falls. An  
image and WEN signal are always output together. For more details, refer to the WEN signal. (The falling  
edge of an internal VD signal is the same in phase as the beginning of an equalizing pulse in a SYNC V  
area.)  
Note  
: An image is superimposed when the next exposure ends before the previous image is output.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 2  
(RESET MODE)  
For setting the shutter speed using TRG width  
Mode transition state  
External input  
inhibition area  
(50 ms)  
External trigger  
shutter operation  
3
External trigger shutter operation  
*
Normal operation  
Trigger  
1
2
1
*
Trigger  
3
*
2
2
*
Exposure time Te  
*
Exposure  
time Te  
1
Video out  
WEN  
2
4
*
1H to 2H  
4
*
1H to 2H  
250H  
250H  
250H  
(XC-ES50/ES30,  
XC-EI50/EI30)  
(XC-ES50/ES30,  
XC-EI50/EI30)  
(XC-ES50/ES30,  
XC-EI50/EI30)  
293H  
293H  
293H  
(XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE)  
(XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE)  
(XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE)  
1: This is a signal input from the outside. The trigger interval should be trigger pulse width + 1 field + 2H  
period or more. The trigger interval shorter than described above cannot be ensured. If a trigger pulse is  
not input under the prescribed conditions, the normal operation is ensured several V after a change in  
input operation under the prescribed conditions.  
*
2: Exposure time Te Te = Trigger width + 97 µs (XC-ES50/ES30, XC-EI50/EI30),  
Te = Trigger width + 120 µs (XC-ES50CE/ES30CE, XC-EI50CE/EI30CE)  
(The trigger width should be between 2 µs and 1/4 s)  
*
*
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
4: AVD signal is generated 1H to 2H after a trigger pulse falls, and an image is output in synchronization with  
the VD signal.  
*
*
5: When the external trigger shutter mode changes into the normal operation mode, a WEN signal is output.  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
TIMING CHART OF EXTERNAL TRIGGER SHUTTER - MODE 2 (RESET MODE)  
For setting the shutter speed using DIP switch  
Mode transition state  
External input  
External trigger  
shutter operation  
inhibition area  
(50 ms)  
3
External trigger shutter operation  
*
Normal operation  
1
2
1
*
Trigger  
3
*
Trigger  
2
*
Exposure time Te  
2
*
Exposure  
time Te  
1
2
Video out  
WEN  
4
4
*
T
*
T
250H  
250H  
(XC-ES50/ES30,  
XC-EI50/EI30)  
(XC-ES50/ES30,  
XC-EI50/EI30)  
293H  
293H  
(XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE)  
(XC-ES50CE/ES30CE,  
XC-EI50CE/EI30CE)  
1: This is a signal input from the outside. The trigger interval should be shutter speed (DIP switch) + 1 field  
+ 2H period or more. The trigger interval shorter than described above cannot be ensured. If a trigger  
pulse is not input under the prescribed conditions, the normal operation is engaged several V after a  
change in input operation under the prescribed conditions.  
*
2: As shown in the table on page 7, exposure time Te is determined by the setting of a DIP switch.  
*
*
3: The normal operation state is engaged when the high period exceeds 1/3 sec. After that, the external  
trigger shutter operation is engaged when the trigger pulse goes “low”. In this case, the area between the  
falling edge of a trigger pulse and the subsequent 50 ms period is an external input inhibition area. During  
the trigger inhibit period, an input trigger may be missed.  
4: After a period set by a DIP switch from the rising edge of the trigger, an image is output.  
*
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
DIMENSIONS  
XC-ES50/50CE, XC-EI50/EI50CE  
XC-ES30/30CE, XC-EI30/EI30CE  
(XC-ES30 model)  
2-M2 deep 2.5  
(Unit : mm)  
6.5  
C0.5  
C0.5  
6.5  
5.5  
29  
10  
32  
C0.5  
4-M2 deep 2.5  
6.5  
22  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
SPECTRAL RESPONSE CHARACTERISTICS  
(Typycal Value)  
XC-ES30  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0.0  
400  
500  
600  
700  
800  
900  
1000  
Wave Length [nm]  
XC-ES30CE  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0.0  
400  
500  
600  
700  
800  
900  
1000  
Wave Length [nm]  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
SPECTRAL RESPONSE CHARACTERISTICS  
(Typycal Value)  
XC-ES50  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0.0  
400  
500  
600  
700  
800  
900  
1000  
Wave Length [nm]  
XC-ES50CE  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0.0  
400  
500  
600  
700  
800  
900  
1000  
Wave Length [nm]  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
SPECTRAL RESPONSE CHARACTERISTICS  
(Typycal Value)  
XC-EI30  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0.0  
400  
500  
600  
700  
800  
900  
1000  
Wave Length [nm]  
XC-EI30CE  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0.0  
400  
500  
600  
700  
800  
900  
1000  
Wave Length [nm]  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
SPECTRAL RESPONSE CHARACTERISTICS  
(Typycal Value)  
XC-EI50  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0.0  
400  
500  
600  
700  
800  
900  
1000  
Wave Length [nm]  
XC-EI50CE  
1.0  
0.9  
0.8  
0.7  
0.6  
0.5  
0.4  
0.3  
0.2  
0.1  
0.0  
400  
500  
600  
700  
800  
900  
1000  
Wave Length [nm]  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
VARIOUS LENS SELECTION  
The following shows the various lens specifications of the accessories available.  
XC-ES50/50CE, XC-ES30/30CE  
XC-EI50/50CE, XC-EI30/30CE compatibility  
List of C-Mount Lens  
Model name  
Focal distance (mm)  
VLC-08YM  
8
VLC-12YM  
12  
VLC-16Y-M  
16  
VLC-25Y-M  
25  
VLC-50Y-M  
50  
1: 1.4  
1: 1.8  
1: 1.4  
1: 1.6  
1: 2.8  
Maximum aperture ratio  
Manual  
Manual  
42.6˚×32.6˚  
32.6˚×24.8˚  
207  
Manual  
Manual  
29.6˚×22.4˚  
22.4˚×16.9˚  
208  
Manual  
Manual  
22.6˚×17.0˚  
17.0˚×12.8˚  
289  
Manual  
Manual  
14.6˚×11.0˚  
11.0˚×8.2˚  
204  
Manual  
Manual  
7.3˚×5.5˚  
5.5˚×4.1˚  
438  
Iris  
Operation  
Focus  
Field angle  
1/2" CCD  
1/3" CCD  
(Horizontal x vertical)  
MOD (mm)  
181×132.8  
181.3×133.3  
136.8×100  
137×100.3  
11.54  
125.2×92.1  
125.5×92.5  
94.7×69.6  
94.8×69.6  
10.99  
119.4×88.5  
119.6×88.8  
90×66.8  
90.4×66.9  
12.50  
52.1×38.8  
52.1×38.9  
39.4×29.3  
39.4×29.3  
11.60  
49.2×37  
49.7×37.1  
37.2×27.9  
37.5×27.9  
22.10  
XC-ES50/EI50  
XC-ES50CE/EI50CE  
XC-ES30/EI30  
XC-ES30CE/EI30CE  
Image pickup range during  
maximum proximity  
(horizontal × vertical) (mm)  
Back focus (mm)  
Flange back (mm)  
Mass (g)  
17.526  
17.526  
17.526  
17.526  
17.526  
50  
40  
40  
50  
42  
MOD: Minimum object distance between the tip of the lens body and the object  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
XC-E series  
Sony reserves the right to change specifications of the products and discontinue products without notice.  
Technical information contained herein is for reference only and does not convey any license by any implication or otherwise  
under any intellectual property right or other right of Sony or third parties.  
Sony cannot assume responsibility for any right infringements arising out of the use of this information.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CCD B/W VIDEO  
CAMERA MODULE  
XC-ES50/50CE  
XC-ES30/30CE  
XC-EI50/50CE  
XC-EI30/30CE  
Sales Office :  
Japan  
Sony Corporation  
4-14-1 Asahi-cho, Atsugi-shi, Kanagawa, 243-0014 Japan  
Tel: +81-46-227-2346  
Tel: +81-46-230-5873  
Fax: +81-46-227-2347  
Fax: +81-46-230-6243  
USA  
Sony Electronics Inc.  
HQ  
1 Sony Drive Park Ridge, NJ 07656  
Tel: +1-800-686-7669  
Canada  
Sony of Canada Ltd.  
115 Gordon Baker Rd, Toronto, Ontario M2H 3R6  
Tel: +1-416-499-1414 Fax: +1-416-497-1774  
Europe  
http://www.pro.sony-europe.com/ISP  
Sony Broadcast & Professional  
HQ  
15, rue Floreal 75831 Paris Cedex 17, France  
Tel: +33-1-55-90-35-11  
Fax: +33-1-55-90-35-17  
Germany  
Hugo-Eckener-Str. 20, 50829 Koln  
Tel: +49-221-5966-322  
Fax: +49-221-5966-491  
France  
15, rue Floreal 75831 Paris Cedex 17  
Tel: +33-1-55-90-41-62  
Fax: +33-1-55-90-13-57  
UK  
The Heights, Brooklands, Weybridge, Surrey KT13 0XW  
Tel: +44-1932-816-340  
Nordic  
Fax: +44-1932-817011  
Per Albin Hanssons vag 20 S-214 32 Malmo Sweden  
Tel: +46-40-190-800  
Italy  
Fax : +46-40-190-450  
Via Galileo Galilei 40 I-20092 Cinisello Balsamo, Milano  
Tel: +39-02-618-38-431  
Fax : +39-02-618-38-402  
© 1999 Sony Corporation. All rights reserved.  
Reproduction in whole or in part without written permission is prohibited.  
00B  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sherwood VCR CDC 690T User Manual
Sierra Monitor Corporation Carbon Monoxide Alarm 4100 33 User Manual
Snapper Edger ET 200 User Manual
Sony Home Theater System BDV E370 User Manual
Sony Portable Speaker SRS Z30 Z31 User Manual
Speco Technologies Security Camera CVC 105CM User Manual
SPX Cooling Technologies Refrigerator MarleyAV Series User Manual
Sub Zero Freezer Sub Zero User Manual
Sylvania Flat Panel Television SRT4127FA User Manual
Sylvania Headphones SIP292 User Manual