12” Retro Metal Table Fan
Model No: FT1-30-42
Operating Instructions
FT1-30-41
Black Chrome
FT1-30-42
3068664
Brushed Nickel
© 2012 Soleus Air International
Download from Www.Somanuals.com. All Manuals Search And Download.
This product employs overload protection (fuse). A blown fuse indicates an overload or short-circuit
situation. If the fuse blows, unplug the product from the outlet. Replace the fuse per the instructions
below and check the product. If the replacement fuse blows, a short-circuit may be present and the
product should be discarded or returned to an authorized service facility for examination and/or
repair.
HOW TO REPLACE THE FUSE
1. Unplug the fan from the outlet. Place the plug on a firm, flat surface.
Open the fuse cover, located on the top of the plug, using your thumb
or a flathead screwdriver to slide the over towards the prongs.
NOTE: Ensure that the fuse cover is completely open before attempting
to remove the fuse.
2. Remove the fuse carefully by using a small screwdriver to pry the fuse
out of the compartment by the metal ends of the fuse.
3. Risk of fire. Insert a new 5 Amp, 125 Volt fuse into the fuse compart-
ment, making sure that the fuse is securely in place.
4. Slide the fuse cover closed completely. If the fuse cover is difficult to
close, make sure the fuse is properly secured in place by pressing
down on the metal ends of the fuse.
CAUTION: Risk of fire. Do not replace the attachment plug. It contains a
safety device (fuse) that should not be removed. Do not use the product if
the attachment plug is damaged.
To avoid a risk of fire, only replace with a 5 Amp, 125 Volt fuse.
To order a new fuse, contact Soleus Air at: (888)-876-5387
3
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
This fan has a grounded three
pronged plug intended to fit into a
three slot outlet. (A) An adapter is
available for connecting three
pronged plugs into two slot outlets.
(B) When doing so, the green ground-
ing tab extending from the adapter
must be fastened under the wall
plate’s mounting screw. The adapter
should not be used if a three-slot out-
let is available.
DO NOT DEFEAT THE SAFETY
PURPOSE OF THE GROUNDED
PLUG.
TECHNICAL SPECIFICATIONS
Model Number
FT1-30-41 & FT1-30-42
Voltage Rating
120V, 60Hz
Power Consumption
Product Dimensions
Product Weight
35W
13 in. (W) x 10 in. (D) x 18 in. (H)
6.7 lbs
4
Download from Www.Somanuals.com. All Manuals Search And Download.
PRODUCT DIAGRAM
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ASSEMBLY INSTRUCTIONS
Estimated assembly time: Approximately 5 minutes
1. Remove the fan and packaging materials from the
box.
2. Remove the mounting nut from the motor shaft.
1. Position the back grille over the motor shaft, aligning
the holes in the back grille with the two knobs that
protrude from the motor. Make sure the handle is at
the top.
2. Secure the back grille by screwing on the mounting
nut. Turn clockwise and tighten firmly.
1. Slide the fan blade onto the mounting shaft with the
shaft sleeve facing the motor.
2. Align securing screw with flat groove in the motor
shaft and tighten with Phillips screwdriver.
1. Position front grille so logo is horizontal.
2. Secure the top tab to the back grille.
3. Snap the four remaining metal clips to complete the
assembly.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATING INSTRUCTIONS
1. Set the fan on a stable, level surface.
2. Confirm that the Speed Control Lever is set to “O” (off). Plug the cord into a standard
outlet.
3. Adjust to the desired speed setting:
O: Off
I: Low Speed
II: Medium Speed
III: High Speed
4. The fan can operate in oscillation or stationary mode. Press the Oscillation Knob down to
activate the oscillating mode. To stop oscillation, pull control knob up.
5. To adjust the tilt of the fan head, loosen the Adjustable Tilt Knob and adjust to the desired
angle. Tighten knob.
6. Unplug the fan when not in use.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
CLEANING & MAINTENANCE
1. Turn the fan off and unplug the unit.
2. Wipe the fan down with a damp cloth for most efficient operation.
3. Air dry the fan completely before use.
4. Never use abrasive cleaning agents or solvents. This may cause damage or deterioration to the surface of
the unit.
5. Do not immerse the fan in any form of liquid. Do not allow water to drip on or into the fan motor
housing.
STORAGE
If the fan will not be used for a long period of time, store it in a cool, dry location when not in use. To
prevent dust and dirt build-up, use the original packaging to repack the unit.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
WARRANTY
One Year Limited Warranty
Soleus International Inc. warrants the accompanying Soleus Air Table Fan to be free of defects in material and work-
manship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original
retail purchase in the United States.
If the unit exhibits a defect in normal use, Soleus International Inc. will, at its option, either repair or replace it, free of
charge within a reasonable time after the unit is returned during the warranty period.
As a condition to any warranty service obligation, the consumer must present this Warranty Certificate along with a
copy of the original purchase invoice.
THIS WARRANTY DOES NOT COVER:
•
Damage, accidental or otherwise, to the unit while in the possession of a consumer not caused by a defect in
material or workmanship.
•
Damage caused by consumer misuse, tampering, or failure to follow the care and special handling provisions
in the instructions. This includes dents, accidental or otherwise, to the base and head of the unit.
•
•
Damage to the finish of the case, or other appearance parts caused by wear.
Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus
International Inc.
•
Freight and Insurance cost for the warranty service.
ALL WARRANTIES, INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO
ONE-YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY. SOLEUS INTERNATIONAL INC.
DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT
SHALL SOLEUS INTERNATIONAL INC’S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR
BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT.
This warranty covers only new products purchased from our authorized dealers or retailers. It does not cover used, sal-
vaged, or refurbished products.
As some states do not allow the limitation or exclusion of incidental or consequential damages, or do not allow
limitation on implied warranties, the above limitations and exclusions may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights that vary from state to state.
For Technical Support & Warranty Service
Please Call (888) 876-5387
Or Write To:
Soleus International Inc.
20035 E. Walnut Dr. N.
City of Industry, CA 91789 USA
9
Download from Www.Somanuals.com. All Manuals Search And Download.
|