Soleus Air Air Conditioner KFR KFS Series User Manual

Download from Www.Somanuals.com. All Manuals Search And Download.  
Use 230V/60Hz or 115V/60Hz  
power supply only .  
Do not turn off the power supply cir- Keep the power supply circuit breaker Depending on the electrical specifi-  
cuit breaker or pull out the unit power and power plug free from any type of cations of your unit, use only 230V/  
cord during unit operation. This may debris. If using a power supply cord, be 60Hz or 115V/60Hz power supply.  
cause electrical hazards and/ or a fire. sure to connect to plug firmly. This will Failure to do so may result in electri-  
minimize the risk for electrical shock or cal problems or hazards.  
any other type of electrical hazard.  
Power supply wires must be located Never insert any type of object into Be sure that the indoor and outdoor  
in areas where they will not be dam- the outdoor unit fan. Because the fan units are not in operation when discon-  
aged or cut.  
rotates at a high speed, this may necting the power supply to the unit.  
cause injury.  
Any type of repairs or maintenance Be sure that your hands are not wet Be sure that the outdoor unit is free  
done to the units must be done by a when touching any of the operation and clear of any debris around the out-  
professionally licensed contractor. buttons on the indoor unit.  
Any unqualified person should not at-  
side of the unit. Do not place or lean  
any items on the unit.  
tempt to repair the units themselves.  
- 1 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- 3 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- 9 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- 10 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- 14 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications  
PERFORMANCE RATINGS  
MODEL  
Capacity Cooling [BTU/h]  
Capacity Heating [BTU/h]  
SEER  
KFS-12G  
KFR-12G  
12400  
12800  
10.5  
KFR-18G  
18500  
18800  
10.2  
KFR-24G  
23100  
12000  
12000  
10.5  
23266  
10.4  
2.9  
2.9  
3.1  
5.2  
Moisture Removal[Pts/h]  
Air Flow  
340/450/520  
<42  
340/450/520  
<42  
690/810/900  
<44  
890/1100/1200  
<45  
Sound Rating Indoor dB  
Sound Rating Outdoor dB  
Operating Range - Cooling [F]  
Operating Range - Heating [F]  
ELECTRICAL DATA  
Power Source  
<52  
<52  
<58  
<59  
60 to 109  
28 to 75  
60 to 109  
28 to 75  
60 to 109  
28 to 75  
60 to 109  
28 to 75  
115-60-1  
15  
230/208-60-1  
10  
230/208-60-1  
15  
230/208-60-1  
15  
Min. Ampacity [A]  
Cooling Watts Amps  
Heating Watts Amps  
Max TD Fuse/Breaker [A]  
REFRIGERANT LINES  
Connections  
1440 / 11.7  
1420 / 10.8  
28  
1230 / 5.3  
1300 / 5.7  
15  
1870 / 8.1  
1890 / 8.2  
22  
2323 / 10.1  
2379 / 10.3  
27  
Flare  
1/4  
1/2  
49  
Flare  
1/4  
1/2  
49  
Flare  
1/4  
1/2  
49  
Flare  
3/8  
5/8  
49  
Liquid Line OD [in]  
Suction Line OD [in]  
Mac line Length [ft]  
Max Height Difference [ft]  
DIMENSIONS&WEIGHTS  
16  
16  
16  
16  
KFS-12GW  
KFS-12GW  
KFS-12GW  
KFS-12GW  
I
NDOOR SECTION  
24x8x5  
22  
24x8x5  
22  
42x14x11  
29  
46x15x11  
31  
WxHxD [in]  
Shipping Weight [lbs]  
OUTDOOR SECTION  
WxHxD [in]  
KFS-12GWH  
KFS-12GWH  
KFS-12GWH  
KFS-12GWH  
31x22x10  
31x22x10  
73  
38x28x15  
115  
38x39x15  
143  
Shipping Weight [lbs]  
Refrigerant Charge [lbs]  
73  
2
2.1  
2.9  
4.8  
Copyright 2003 Soleus International Inc.  
- 15 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- 16 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation instructions  
Select the installation locations  
Indoor unit installation location:  
l
Locate indoor unit so that there is not obstruction near the supply air or return air  
outlets.  
l
The wall that the indoor unit hangs on must be free from internal obstructions to  
facilitate a clear hole for the refrigeration lines and condensate line to go through.  
l
Proper clearances must be maintained to ceilings and walls per instructions on page 16.  
l
Easy access must be maintained for removal of the air filter.  
l
Indoor unit and remote control must be at least 3 feet from televisions, radios, etc.  
l
Indoor unit and remote control must be kept out of direct sunlight and/or fluorescent  
lighting.  
l
The wall that the indoor unit hangs on must strong enough to bear the weight of the  
unit to ensure quieter operation.  
Outdoor unit installation location:  
l
Outdoor unit location must be well ventilated. Avoid installing where any type of flammable  
gas could leak.  
l
Proper clearances must be maintained per instructions on page 16.  
l
The maximum length for refrigeration lines is 49 ft. For refrigeraton lines exceeding 23ft. an  
additional .75 pounds must be added per 3.5 feet.  
l
The Maximum height between indoor and outdoor units in 25ft. If the outdoor unit is located  
above the indoor unit more than 4 ft., a suction line oil trap must be installed.  
l
The outdoor unit must not be located in environments that have high contents of acidic  
substances, vulcanized gasses, or high salt contents in the air.  
l
The outdoor unit must not be located near locations where dirt, mud, or debris can be caked  
onto the outdoor coil or unit.  
l
The foundation that the outdoor unit sits on must be solid and sound so as to decrease noise vibration.  
l
No obstructions should be placed around the outdoor unit.  
Indoor unit installation  
1. Installing the mounting plate  
l
Hold mounting plate on the wall where unit will be located. Using a level or plumb line,  
ensure that the plate is level. Once the plate is level, mark holes that will be used to  
hold plate on the wall.  
Note: The shape of your mounting plate may be different from  
the one above, but installation method is simllar.  
l
l
l
Remove plate and drill marked hole at a depth of 1.75 inches.  
Insert the screw plugs into the holes and affix the mounting plate using the tapping screws.  
Once mounting plate is securely fastened to the wall, then locate an area on the wall for the access hole for the refrigeration  
line/condensate line/wiring bundle.  
2. Access hole for refrigeration lines/condensate drain line/wiring bundle.  
l
These directions must be followed at least for the condensate drain line. There must  
be rear access for the condensate drain line to drain properly from the unit.  
l
Decide on a location for the access hole according to the location of the unit.  
l
Drill an approximately 2.5 inch hole, making sure that there is a tilt downward of a 1/4  
inch. This will ensure that proper drainage is maintained for the condedsate drain line.  
(If you are not using rear access for the refrigeration lines and wiring, hole will does  
not need to be as large.)  
l
It is recommended that a wall sleeve of some sort (i.e. PVC pipe) be used to keep the hole neat and tidy.  
- 17 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation instructions  
3. Indoor unit refrigeration line installation  
l
The refrigeration lines and wiring can be routed to the outdoor unit in a number of ways (left or right from the back of the  
unit), by using the cut-out access pieces on the casing of the unit.  
l
Bend the refrigeration lines carefully to the required positon in order to be aligned with the drilled hole.  
piping direction  
cut-out  
access  
Note:  
When installing the refrigeration lines at the directions 1, 2 or 4,  
saw the corresponding cut-out piece off the indoor unit casing.  
Saw the cut-out access off  
along the side of the casing  
l
After connecting refrigeraton lines (see directions below), install the condensate drain line (see page21+24fordetailed  
instructions on connecting condensate drain line). Then connect all wiring (see pages 2 5-27 for detailed instructions on  
wiring). After all connections are made, bundle the refrigeration lines, wiring, and condensate drain line together using a  
thermal insulation and vinyl/duct tape.  
Refrigeration lines insulation:  
l
It is important that both the liquid and suction  
refrigeration lines areindividuallyinsulated to ensure  
that they do no sweat and also to maintain proper unit  
capacities. This is necessary since the refrigeration is  
metered from the outdoor unit and will produce condensation on both refrigeration  
lines if not proper insulated.  
Refrigeration lines/Condensate drain line/wiring bundle thermal insulation:  
l
Place the condensate drain line under the refrigeration lines.  
l
Insulation material should be a polythene foam that is approximately a 1/4  
inch wall thickness.  
l
Condensate drain line should have a downward slope at all times to ensure  
proper drainage. Do not allow the drain line to be twisted, horizontal or the  
end of the line be immersed in water. If an extension is added to the drain line, make sure that it is also properly insulated.  
Connection of refrigeration lines:  
l
Do not use contaminated or damaged copper tubing for refrigeration lines. If any of the tubing,  
evaporator or condenser coils have been exposed to the air for more that 15 seconds, it is  
important that they are vacuumed and purged with field-supplied refrigerant. Do not remove  
plastic or rubber plugs and brass nuts from the valves, fittings, tubing, or coils until they are  
ready to be connected.  
l
Use proper tubing cutters to cut the refrigeration lines, advancing the blade of the tubing cutters  
slowly. Extra force or improper cutting will cause tubing distortion and also extra burring.  
l
Once refrigeration tubes are cut, remove burrs from cut edges with a remover. This will avoid  
unevenness on the flare faces, which could cause a gas leak. Hold the ends of the pipes  
downward to prevent metal from going into the tubes.  
l
Insert the flare nuts, mounted on the connection ends of both the indoor and outdoor units onto  
the ends of the copper tubing.  
l
The length of the pipe protruding from the face of the flare die is determined by the particular flaring tool that will be  
used.  
l
Fix the pipe firmly on the flare die. Match the centers of both the flare die and the flaring punch, and then tighten the  
flaring punch fully.  
l
Once flaring is complete, connection of the tubing is ready. Align the center of the tubing and tighten the flare nuts  
using a torque wrench.  
- 18 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- 19 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Mounting the Indoor unit to the Mounting Plate:  
Hook  
l
Hook the indoor unit onto the upper portion of the mounting plate by connecting the hooks at the  
rear top of the indoor unit with the upper edge of the mounting plate.  
l
l
l
To ensure that the hooks are properly seated on the mounting plate, check if the unit can slide  
by moving it to the left and right. If the unit moves, it is not properly seated.  
A unit support plate in the mounting plate can be used if the unit is on a slanted wall and can  
also be used to ease the connection of the refrigeration lines.  
Hook  
Affix the screw underneath the unit to the mounting plated after completed with installation.  
Suppport plate  
Connection of condensate drain extension line:  
l
Place glue on the end of the drain line extension end.  
l
Fully insert the end of the drain line to the extension line. Make sure it is properly inserted to no less than 3/8 of an inch so that water  
does not leak from the hose.  
- 20 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation instructions  
Outdoor unit installation  
1. Install the outdoor unit  
l
Outdoor unit must be mounted on a solid, level foundation. If possible, affix unit using bolts to the foundation.  
l
If installing on a wall or structure, be sure that construction of the wall or structure can support the weight of the unit and  
that consideration is given to the integrity of the construction. Since the unit can vibrate during operation, movement of  
sound of the unit should be considered when installing the unit.  
l
Since the unit discharges air during operation, plants or other obstruction should be free and clear of the unit to ensure  
proper operation.  
l
Owners should advised to avoid lawn mowers or other machinery discharge toward the unit, as debris can damage the  
finned coil surfaces and reduce effciency of the unit.  
2. Outdoor unit refrigeration line connection  
l
Remove the valve caps at the outdoor unit where f\refrigeration tubing will be connected.  
l
Connect the refrigeration tubing using flaring techniques described earlier  
in the indoor unit installation. Be sure to use required torque.  
Attention  
l
A baffle is needed when installation is in locations near the sea or areas  
with strong winds.  
l
Be sure that unit airflow is not obstructed in any way or that reciculation of  
discharge air does not occur.  
- 21 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation instructions  
3. Wiring connection  
l
Remove the electrical cover of outdoor unit (1 screw).  
l
Connect wires as shown below in the illustrations.  
Outdoor unit terminal block  
Heat Pump  
Connect to Power Supply  
Power supply inter connecting  
conductors (in conduit A)  
( to the indoor unit)  
Control inter connecting  
conductors(in conduit B)  
( to the indoor unit)  
The conduit should not be loosened after being fixed, otherwise, it may cause abnormal noise when the unit is  
running.  
Number 14 wire should be used for KFR-18GW.  
Number 12 wire should be used for KFR-24GW.  
Number 14 wire should be used for KFR-09GW, KFR-12GW/A.  
Number 16 wire should be used for KFR-12GW.  
- 22 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation instructions  
System Start Up and Charge Adjustment Procedures  
Leakage check  
Properly check refrigeration tubes and connections for any leaks prior to system start up procedures.  
NOTE:  
A is the low-pressure valve  
B is the high-pressure valve  
C and D are the joints of connecting pipes  
of indoor unit.  
Air exhaust  
The outdoor unit is supplied with a R-22 charge sufficient for 15 feet of refrigeration tubing.  
The outdoor unit’s liquid and suction valves are closed to contain the charge within the  
unit. The recommended procedures for charge adjustments are as follows:  
Additional Charge Needed for Refrigeration lines over 15 feet  
Liquid Line O.D. (Inches)  
Additional R-22 (oz / ft)  
1/4  
3/8  
.22  
.58  
1. After connecting the refrigeration tubing to the indoor and outdoor units. connect a  
vacuum pump to the refrigeration valve service ports.  
2. Evacuate through the liquid and suction valve service ports to 500 microns or less for a minimum of 30 minutes. Close  
the valves to the pump and monitor the vacuum for 15 minutes. The vacuum should not rise above 800 microns.  
3. If a vacuum of 500 microns cannot be obtained, or if it rises ablve 800 microns over the 15 minute period, discontinue  
evacuation, pressurize the system with nitrogen and look for leaks. Repair any leaks that are found and repeat step 2.  
4. Close the valves to the vacuum pump, turn the pump off, and disconnect it from the refrigerant valve service ports. Open  
the liquid and suction service valves fully, releasing the R-22 into the system. Connect the service gauges to the refrigerant  
valve service ports.  
5. Set the indoor remote control to cool mode and ensure proper operation. Allow unit to run for a period of 10 minutes to  
allow system pressures to stabilize.  
Make sure that proper pressures are observed.  
*
Check proper temperatures in space, to ensure temperatures match those on remote control.  
*
*
*
*
Check condensate drain hose for proper drainage.  
Check for any abnormal vibration noises and correct as needed.  
Check for any signs of refrigerant leakage.  
6. Set the indoor remote control to heat mode and ensure proper operation. Allow unit to run for a period of 10 minutes to  
allow system pressures to stabilize. Fllow same checkouts as cool mode.  
- 23 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOW TO INSTALL DRAIN ACCESSORIES  
There will be some water dripping from the condenser when the heat pump is working during the heating mode.  
Two drain caps, a drain elbow with rubber collar and a plastic hose (5/8” x 6”) are supplied for user’s choice.  
INSTALLATION STEPS:  
(1) Observe the drainage flow of the three drain holes on the base while pouring water into the condensing unit  
evenly around the condenser. (Figure 1)  
(2) Connect the drain elbow and the plastic hose. (Figure 2)  
(3) Insert the drain elbow connected with the drain hose into the hole which has the largest drainage flow and  
rotate it to the wall side of the building in order to make the drainage flow against the wall. The other two holes  
of the base should be stopped by using the two drain caps. (Figure @)  
NOTE:  
If the drain hole inserted with the drain elbow is not at the desired location, adjust the level of the condensing unit  
slightly, and then reinstall the accessories according to the above steps.  
- 24 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- 25 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- 26 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
!
WARNING  
USE COPPER WIRES ONLY FOR POWER SUPPLY.  
!
!
WARNING:RISKOFELECTRICSHOCKCANCAUSEINJURYORDEATH.  
DISCONNECTALLELECTRICPOWERSUPPLIESBEFORESERVICING.  
DURINGCONNECTIONOFTHEREFRIGERATIONTUBES, IFEXCESSIVE  
TORQUEISIMPOSEDONFLARENUTS,SERVICEVALVEONDISCHARGE  
LINE MAY BE DAMAGED. WHEN TIGHTENING FLARE NUTS OR NARROW  
PIPE, TORQUESHOULDBEADJUSTEDBETWEEN13.7~18.6N.M  
(140~190GF.CM).  
!
DONOTPUTINDOORUNITINLOCATIONSWHEREITMAYGETWET.  
!
!
ELECTRICALINSTALLATIONMUSTBEINACCORDANCEWITHLOCALAND  
NATIONALELECTRICALCODES.  
THEINSTALLATIONOFTHESEUNITSREQUIRESQUALIFIEDPERSONNEL.  
CERTIFIED(APPROVED)POWERSUPPLYCONDUCTORSMUSTBEUSED.  
ANINDEPENDENTBRANCHCIRCUITBREAKERMUSTBEUSED.  
!
!
!
!
MAXIMUMINTERCONNECTINGWIRELENGTHSHOULDNOTEXCEED  
11.3M(37FT.)  
REFRIGERATINGPIPELENGTHMUSTBELIMITEDBETWEEN4~10M  
(13FT~33FT.)IFTHELENGTHEXCEEDS7.62M(25FT.), THECOOLING  
(ORHEATING)CAPACITYMAYBECOMEIMPAIRED.  
!
!
DIFFERENCE IN HEIGHT BETWEEN INDOOR AND OUTDOOR UNIT SHOULD  
NOT EXCEED 7M(26 FT.).  
- 28 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
- 29 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
RUN light blinks  
Defect  
What to check  
Open circuit or short circuit of room  
temperature sensor.  
1 time  
Abnormality of room temperature  
sensor.  
Incorrect connection of the sensor.  
Open circuit or short circuit of defrost  
sensor.  
2 times  
3 times  
4 times  
Abnormality of defrost sensor.  
Abnormality of indoor fan motor.  
Abnormality of outdoor unit.  
No defect-unit in defrost mode.  
Incorrect connection of the sensor.  
Indoor fan motor is defective.  
Bad connection to motor.  
Compressor is defective.  
Refrigerant is low.  
Capacitor is defective.  
Continuous  
blink  
- 30 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Projector PG M20X User Manual
Snapper Lawn Mower ZF2100DKU ZF2300GKU ZF5200M ZF6100M User Manual
Sony Battery Charger AC V700A User Manual
Sony Computer Monitor CPD 110EST User Manual
Sony Network Card BKM FW31 User Manual
Sony Speaker M30 User Manual
Sony Stereo Receiver STR AV220 User Manual
Sungale Digital Photo Frame PF 1023 User Manual
Sylvania MP3 Docking Station SIP215 User Manual
Symphonic CRT Television ST424FF User Manual