Silicon Laboratories Network Card Debug Adapter User Manual

ToolStick Debug Adapter  
TOOLSTICK DEBUG ADAPTER USER S GUIDE  
1. Handling Recommendations  
To enable development, the ToolStick Base Adapter and daughter cards are distributed without any protective  
plastics. To prevent damage to the devices and/or the host PC, please take into consideration the following  
recommendations when using the ToolStick:  
Never connect or disconnect a daughter card to or from the ToolStick Base Adapter while the Base Adapter is  
connected to a PC.  
Always connect and disconnect the ToolStick from the PC by holding the large plastic connector.  
Figure 1. Proper Insertion  
Avoid directly touching any of the other components.  
Figure 2. Improper Insertion  
Manipulate mechanical devices on the daughter cards, such as potentiometers, with care to prevent the base  
adapter or daughter card from accidentally dislodging from their socket.  
Rev. 0.1 9/06  
Copyright © 2006 by Silicon Laboratories  
ToolStick Debug Adapter  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ToolStick Debug Adapter  
4. Hardware Setup using a ToolStick Debug Adapter  
Configure the ToolStick Debug Adapter  
1. Place the jumper J1 in the appropriate position for the I/O voltage of the Target Board being used. Connect pins  
1 and 2 (V  
and V ) for 2.5 V I/O or connect pins 2 and 3 (V and V ) for 3.3 V I/O.  
REG  
IO DD IO  
2. If the Target Board will be powered from the ToolStick Debug Adapter, place a jumper on header J2. If the  
Target Board will be separately powered, ensure that no jumper is installed on header J2.  
Note: Powering the Target Board from the ToolStick Debug Adapter and a separate power supply at the same time could  
cause damage to the ToolStick Base Adapter and/or the Target Board.  
J3  
P2  
J1  
J2  
Figure 4. ToolStick Debug Adapter Jumpers  
Connect the ToolStick Debug Adapter to the Target Board as shown in Figure 5.  
1. If not already assembled, insert the ToolStick Debug Adapter into a ToolStick Base Adapter.  
2. Connect the 10-pin ribbon cable from the ToolStick Debug Adapter to the Target Board debug header.  
3. Connect one end of the USB cable to the USB connector on the ToolStick Debug Adapter.  
4. Connect the other end of the USB cable to a USB port on the PC that will run the Silicon Laboratories IDE.  
5. Connect the AC/DC power adapter to the power jack on the target board, or configure the board to receive  
power from the ToolStick Debug Adapter (see the Target Board Kit User’s Guide for configuration options).  
Notes:  
Use the Reset button in the IDE to reset the target when connected using a ToolStick Debug Adapter.  
Remove power from the target board and the ToolStick Debug Adapter before connecting or disconnecting the  
ribbon cable from the target board. Connecting or disconnecting the cable when the devices have power can  
damage the device and/or the ToolStick Debug Adapter.  
ToolStick  
Debug  
Base Adapter  
Adapter  
Target Board  
Figure 5. Hardware Setup Using a ToolStick Debug Adapter  
Rev. 0.1  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
ToolStick Debug Adapter  
5. Software Setup using a ToolStick Debug Adapter  
The Silicon Laboratories Integrated Development Environment (IDE), along with other software tools, are provided  
for device development and debugging. The IDE is available for download from the Silicon Laboratories website  
and is also available on microcontroller development kit CD-ROMs. Once the IDE has been installed and the hard-  
ware has been connected as shown in Section 4, follow the steps below to built a project, connect and download to  
a target board using the ToolStick Debug Adapter.  
1. Select Project Open Project... to open a previously  
saved project.  
2. Before connecting to the target device, several connection  
options may need to be set. Open the Connection Options  
window (shown in Figure 6) by selecting Options →  
Connection Options... in the IDE menu.  
3. Select USB Debug Adapter in the “Serial Adapter” section.  
4. If more than one adapter is connected, choose the  
appropriate serial number from the drop-down list.  
5. Next, the correct “Debug Interface” must be selected. Check  
the Debug Interface corresponding to the Silicon  
Laboratories device on the target board.  
6. Once all the selections are made, click the OK button to  
close the window.  
7. Click the Connect button in the toolbar or select Debug →  
Connect from the menu to connect to the device.  
8. Download the project to the target by clicking the Download  
Code button in the toolbar.  
9. Save the project when finished with the debug session to  
Figure 6. Connection Options  
preserve the current target build configuration, editor settings  
and the location of all open debug views. To save the project,  
select Project Save Project As... from the menu. Create  
a new name for the project and click on Save.  
4
Rev. 0.1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
ToolStick Debug Adapter  
6. ToolStick Debug Adaper Schematic  
Rev. 0.1  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ToolStick Debug Adapter  
CONTACT INFORMATION  
Silicon Laboratories Inc.  
400 West Cesar Chavez  
Austin, TX 78701  
Tel: 1+(512) 416-8500  
Fax: 1+(512) 416-9669  
Toll Free: 1+(877) 444-3032  
The information in this document is believed to be accurate in all respects at the time of publication but is subject to change without notice.  
Silicon Laboratories assumes no responsibility for errors and omissions, and disclaims responsibility for any consequences resulting from  
the use of information included herein. Additionally, Silicon Laboratories assumes no responsibility for the functioning of undescribed features  
or parameters. Silicon Laboratories reserves the right to make changes without further notice. Silicon Laboratories makes no warranty, rep-  
resentation or guarantee regarding the suitability of its products for any particular purpose, nor does Silicon Laboratories assume any liability  
arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation conse-  
quential or incidental damages. Silicon Laboratories products are not designed, intended, or authorized for use in applications intended to  
support or sustain life, or for any other application in which the failure of the Silicon Laboratories product could create a situation where per-  
sonal injury or death may occur. Should Buyer purchase or use Silicon Laboratories products for any such unintended or unauthorized ap-  
plication, Buyer shall indemnify and hold Silicon Laboratories harmless against all claims and damages.  
Silicon Laboratories and Silicon Labs are trademarks of Silicon Laboratories Inc.  
Other products or brandnames mentioned herein are trademarks or registered trademarks of their respective holders.  
6
Rev. 0.1  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Calculator EL 500W User Manual
Sharp Stereo System CD DH950P User Manual
Shure Headphones PGA52 User Manual
Shure Microphone Beta 52A User Manual
Shure Microphone MX692 User Manual
Sony Car Amplifier TA E1000ESD User Manual
Sony Cash Register ER A410 User Manual
Sunbeam Humidifier 129857 User Manual
Sunrise Medical Mobility Aid Quickie P120 User Manual
Tanaka Brush Cutter TBC 422 User Manual