Sierra Monitor Corporation Stud Sensor PSE530 User Manual

Pressure Sensor  
(addendum information)  
(
)
Installation  
Outline with Dimensions in mm  
Attaching the connector to the lead wire  
Connector  
Connector Connecting Disconnecting  
When connecting the connector, insert it straight onto the pin  
holding the lever and connector body between fingers and lock  
the connector by pushing the lever claw into the square groove  
in the housing until connector clicks.  
When disconnecting the connector, push down the lever by  
thumb to disengage the lever claw from the square groove.  
Then pull the connector straight out.  
Operation Manual  
PSE530 Series  
PSE53 -M5  
Sensor wire is stripped as shown in  
/
Connector  
cover  
M5 0.8  
the right figure.  
20mm or more  
3.4  
29.4  
27.2  
Pressure port  
The Insulation of the corresponding  
color shown in the following table is  
put into the pin of the number stamped  
Insulation  
on the connector for sensor connection to the bottom.  
Pin No.  
Color of Insulation  
Brown (DC (+) )  
N.C.  
Blue (DC (-) )  
Black (IN:1 to 5VDC)  
3
12  
1
2
3
4
4
5
5.5  
PSE200 Series  
PSE300 Series  
PSE53 -R06  
R07  
A
1
2
3
4
It checks that the above-mentioned preparation  
work has been performed correctly, and A part  
shown in right figure is pushed by hand and makes  
temporary connection.  
45.5  
43.3  
Pressure port  
3.4  
Lever  
A part center is straightly pushed in by tools, such as pliers.  
Re-use cannot be performed once it connects the connector for  
sensor connection completely.  
Connector for Sensor  
Lead Wire  
Lever  
A sensor connector cannot be taken apart for  
reuse once it is crimped.If the wire arrangement  
is incorrect or if the wire insertion fails,  
Model No.  
PSE53 -R06  
PSE53 -R07  
Applicable port size(D)  
Thank you for purchasing the SMC PSE530 Series Pressure  
Sensor.  
Please read this manual carefully before operating pressure  
sensor and understand pressure sensor, its capabilities and  
limitations. Please keep this manual handy for future reference.  
6mm  
Example of Internal Circuit and Wiring  
Output Specification  
1/4inch  
4
3
2
use a new sensor connector.  
1
When connecting the connector to  
PSE200/PSE300 series, please use  
When connect cable for sensor  
Brown DC  
(+)  
Voltage output :  
1 to 5V  
Output impedance :  
9.8  
the connector for Sensor Lead Wire(ZS-28-C) or  
as below.  
Model No.  
37104-3101-000FL  
1k  
Ω
Maker  
(c)Sumitomo 3M  
Tyco Electronics AMP  
OMRON  
Black OUT  
(Analog output)  
Approx. 1kΩ  
+
-
12 to 24V  
DC  
3-1473562-4  
XN2A-1430  
Blue DC  
(-)  
Please contact with each connector maker about  
catalogue.  
SAFETY  
Specification  
The Pressure Sensor and this manual contain essential  
information for the protection of users and others from possible  
injury and property damage and to ensure correct handling.  
Please check that you fully understand the definition of the  
following messages (signs) before going on to read the text,  
and always follow the instructions.  
How to connect the cable for sensor.(Optional)  
Pick with fingers the hemale connector of cable for sensor.  
Insert it paying attention of connector direction.  
OPERATOR  
PSE533-  
Model No.  
PSE530-  
PSE531-  
PSE532-  
This operation manual has been written for those who have  
knowledge of machinery and apparatus that use pneumatic  
equipment and have full knowledge of assembly, operation  
and maintenance of such equipment.  
Rated pressure range 0 to 101MPa 0 to -101kPa 0 to 101kPa -101 to 101kPa  
Withstand pressure  
Fluid  
1.5MPa  
500kPa  
Air, Non-corrosive gases, Incombustible gases  
12 to 24VDC, ripple(p-p)10% or less (Protection against inverse connection)  
15mA or less  
Power supply  
Current consumption  
Please read this operation manual carefully and understand it  
before assembling, operating or providing maintenance  
service to the pressure sensor.  
Sensor  
IMPORTANT MESSAGES  
Read this manual and follow its instructions. Signal words  
such as WARNING and NOTE will be followed by important  
safety information that must be carefully reviewed.  
Voltage: 1 to 5V±2%F.S. or less (Rated pressure range)  
Linearity : ±1%F.S. or less Output impedance : Approx.1kΩ  
Analog  
output  
Voltage  
output  
Male connector  
Repeatability  
±1%F.S. or less  
NOTE  
Effect form power supply  
Temperature Characteristic  
Enclosure  
±1%F.S. or less with standard of analog output at 18V in the range of 12 to 24VDC  
±2%F.S. or less (25reference)  
Female connector  
Indicates a potentially hazardous situation  
which could result in death or serious  
injury if you do not follow instructions.  
Follow the instructions given below when handling your  
pressure sensor. Otherwise, the sensor may be damaged  
or may fail, thereby resulting in malfunction.  
IP40  
Cable for sensor have connector cover in order to prevent fall of  
female connector. Paying attention for connector cover direction,  
install on the sensor, rotate clockwise, and lock it.  
To remove cable for sensor, rotate the connector cover anti-  
clockwise, relese lock, and remove connector cover.  
After removing connector cover, pick with female connector with  
fingers and pull out.  
Operation : 0 to 50,Storage :-10 to 70(No condensation, No freezing)  
1000VAC, 50/60Hz, 1minute (Between lead block and case)  
5MΩ or more 500VDC (Between lead block and case)  
Ambiebt temperature  
Withstand voltage  
Insulation resistance  
Do not drop it, bring it into collision with other objects or apply  
excessive shock (980m/s2 or more).  
Do not pull the lead wire with force nor lift the main unit by  
holding the lead wire. (Pulling strength less than 23N)  
Do not insert wire nor other article into the pressure port.  
Perform wiring and cable correctly.  
Do not perform wire or cable while power is on.  
Do not wire with the same circuit of power line or high-voltage  
line.  
Connect Terminal FG to the ground when using a switching  
regulator obtained on the commercial market.  
Keeping from water and dust, set an air tube to the safety  
area.  
WARNING  
10 to 500Hz smaller one 1.5mm or 98m/s2 double amplitude, 2 hours each in direction  
of X, Y and Z  
Vibration proof  
Do not disassemble, remodel (including change of  
printed circuit board) or repair.  
An injury or failure can result.  
980m/s2 3times each in directions of X ,Y and Z respectively  
CE MARKING  
Impact proof  
Standard  
Halogen free heavy insulation cable, φ2.7, 0.15mm2, 3wire, 3m  
Cable  
Lock  
Do not operate beyond specification range.  
Fire, malfunction or sensor damage can result.  
Piping Specification  
Model No.  
Sensor  
M5  
R06  
R07  
Connector cover  
Port size  
M5×0.8  
φ6 Reducer  
1/4inch Reducer  
Do not operate in a combustible gas or explosive  
gas atmosphere.  
Fire or an explosion can result.  
Sensor pressure sensing part : Silicon O-ring : NBR  
Material  
Unlock  
Body : SUS303  
Body : PBT  
38g  
41g  
7g  
With cable(3m)  
Weight  
This pressure sensor is not an explosion proof type.  
3.8g  
Excluding cable  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Printer AR M450 User Manual
Sigma Fish Finder EM 140 DG User Manual
Silvercrest Clock Radio KH2217 User Manual
Silvercrest Universal Remote KH 2158 User Manual
Sony Camcorder CCD TR3100E User Manual
Sony Digital Photo Frame DPF C1000 User Manual
Sony Portable DVD Player D V500 User Manual
Sterling Plumbing Hot Tub 76111110 User Manual
Sunbeam Automobile Accessories VB6500 User Manual
Sun Microsystems Network Card SPARCcenter 2000 User Manual