Sharp Refrigerator AC880 User Manual

OPERATION  
&
MAINTENANCE  
MANUAL  
AC880  
Refrigerant Handling System  
Manual P/N 035-80749-00  
Download from Www.Somanuals.com. All Manuals Search And Download.  
BEFORE USING THE AC880  
Check for any shipping damage. Place a claim with carrier if damage is discovered. DO NOT USE A DAMAGED UNIT.  
Complete and return the Warranty Card to activate technical support service and warranty coverage.  
These general instructions describe normal operation and maintenance situations encountered with the AC880. Failure  
to read and comply with these instructions or any one of the limitations noted herein can result in serious injury and/or  
property damage.  
A few minutes spent reading these instructions can make an operator aware of dangerous practices to avoid and  
precautions to take for his own safety and the safety of others. The instructions should not be interpreted to anticipate  
every possible contingency.  
The AC880 should not be operated or serviced by any person who has not read all the contents of this manual.  
It is the responsibility of the owner/user to operate the AC880 in accordance with all specifications and laws which apply.  
A regular schedule of inspection of the AC880 should be established and records maintained with special attention given  
to Hoses, Compressor Oil Level, Vacuum Pump Oil Level, and Filters.  
SAFETY PRECAUTIONS  
Recover, Recycle, and Charge only the refrigerant for which the machine is configured.  
Wear safety glasses and protective gloves. Refrigerant has a very low boiling point and can cause frostbite.  
Follow the AC880 operating procedures sequentially to avoid prematurely disconnecting hoses or opening valves which  
may release refrigerant to the atmosphere.  
Do not expose the AC880 to moisture or operate in wet areas.  
Use the AC880 in locations with mechanical ventilation that provides at least four air changes per hour.  
Hoses used with the AC880 must have shutoff devices within 12 inches (30 centimeters) of the connection point to the  
A/C System to minimize the introduction of Non-Condensable Gas (Air) into the AC880 and the release of refrigerant  
when being disconnected.  
Disconnect power before performing any maintenance or service on the AC880.  
Connect the AC880 to a properly grounded receptacle. Do not overload the circuit.  
Avoid using an extension cord with the AC880. If necessary use a good condition three wire, grounded, #14 AWG or  
larger extension cord of the shortest possible length.  
Do not connect the AC880 to the liquid side of any A/C System with a capacity greater than 4 lbs (1.8 Kg). Refrigerant  
in A/C Systems having larger capacities must be recovered from the vapor side only.  
Never connect the Red or Blue Hose on the rear of the AC880 to the Liquid Port of a Cylinder of Refrigerant to fill the  
Charge Cylinder. Doing so may cause the Compressor to fail and void the warranty.  
Avoid breathing refrigerant or lubricant vapor or mist. Exposure may irritate eyes, nose and throat. If accidental system  
discharge occurs, ventilate work area before continuing.  
Additional health and safety information may be obtained from refrigerant and lubricant manufacturers.  
Special Considerations with R134a  
R134a has been shown to be nonflammable at ambient temperature and atmospheric pressure. However, tests under  
controlled conditions have indicated that at pressures above atmospheric and with air concentrations greater than 60  
percent by volume, R134a can form combustible mixtures.  
While it is recognized that an ignition source is also required for combustion to occur, the presence of combustible  
mixtures is a potentially dangerous situation and should be avoided.  
Under no circumstances should any equipment be pressure tested or leak tested with Air and R134a mixtures. Do not  
use compressed air (shop air) for leak detection in R134a systems.  
Page 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
USING THE AC880  
Note: The purpose of this discussion is to familiarize the user with the features and functions of the AC880 Refrigerant  
Handling Station. The procedures discussed in this manual assume that the AC880 has been set up in accordance  
with the figures which are referred to and that the AC880 has been connected to the proper power supply. This manual  
does not illustrate correct A/C service, but rather how to correctly use the AC880.  
The AC880 is microprocessor controlled with a menu driven user interface. All of the functions of the AC880 are accessed  
by pressing a few simple key strokes and following the prompts. The internal Charging Cylinder is attached to a strain gauge  
measuring device (load cell) and the weight is electronically displayed.  
The AC880 has a Fill Cylinder feature that allows refrigerant to be loaded directly into the Charging Cylinder without going  
through the normal Recover/Recycle mode. When selected, this feature allows the AC880 Charging Cylinder to be re-filled  
in just a few minutes, at which point it will automatically stop at approximately 13 lbs (6 Kg).  
The AC880 Recovers and Recycles simultaneously in a true “single pass” through the filters and stores the refrigerant in the  
Charging Cylinder where it is immediately available for use. This process automatically stops at 17.5 lbs (8 Kg) or when a  
15 In Hg (-0.5 Bar) vacuum is sensed. The AC880 will wait for a minimum factory default of two minutes for “out gassing”  
of cold refrigerant to raise the pressure back up to 3 psig (0.2 Bar) which would cause the Recover/Recycle process to start  
again and reset this two minute Recycle Hold Timer before displaying that the process is complete. The Recycle Hold Timer  
can be changed every time a Recover/Recycle procedure is run. Longer times should be selected on colder days or for A/C  
Systems with large liquid capacities. Increasing this value may increase total time to Recover/Recycle while decreasing the  
time may result in an incomplete Recovery of the A/C System. Refer to the chart below for guidelines on setting the Recycle  
Hold Timer. The value entered is stored in the memory of the AC880 and becomes the default value each time it is set. Non-  
Condensable Gases are vented automatically during Recovery/Recycle. The Amount of refrigerant recycled is displayed at  
the end of the procedure. This value is added to the Total Amount Recycled and stored in the memory of the AC880 (See  
Access Stored Data on Page 12).  
Temperature  
Less than 500F (100C) 500F (100C) to 800F (26.50C) Greater than 800F (26.50C)  
10 minutes 5 minutes 2 minutes  
Recycle Hold Time  
An integrated Deep Vacuum Pump draws on both the High and Low Hoses, ensuring complete evacuation of the A/C  
System. The amount of time that the Vacuum Pump has been programmed to run will count down on the display. The value  
entered is stored in the memory of the AC880 and becomes the default value each time it is set. The Low Pressure Gauge  
can be used to monitor a rise in A/C System pressure. When programmed to do so, the AC880 will pause and start a count  
up timer indicating how long the Vacuum Pump has been off, thus allowing the operator to determine if a vacuum leak is  
present based on increasing pressure over time. A rapid rise in pressure indicates the presence of a large leak that should  
be repaired. A slow rise in pressure may simply indicate that a longer Recycle Hold Time or Vacuum Time value should have  
been entered. A relatively constant vacuum reading over a long period of time (less than 2 InHg rise over ten minutes) is the  
most accurate way to check for vacuum leaks. The AC880 can also be programmed to pause to allow oil to be added to the  
A/C System after vacuuming and prior to charging.  
Charging is done from the internal Charging Cylinder. The A/C Capacity is entered using the Keypad. The value entered is  
stored in the memory of the AC880 and becomes the default value each time it is set. The AC880 can dispense liquid  
refrigerant through either the High or Low Side Hose by changing the position of a selector switch. As refrigerant leaves the  
AC880, the display will show an increasing weight to the programmed charge amount plus a factory set one ounce (0.03 Kg)  
Over Charge Amountnecessaryfor compensation of refrigerantloss in the hoses. This Over Charge Amountcan be changed  
to accommodate different operating conditions (see Set Over Charge Amount on Page 13.) An integrated heater  
automatically engages whenever Charging occurs. The amount of refrigerant charged is added to the total amount charged  
and stored in the memory of the AC880 (see Access Stored Data on Page 12).  
The AC880 can be programmed to perform the Recover/Recycle, Deep Vacuum and Charge in a completely Automatic  
mode. The AC880 will always go through the Recover/Recycle procedure, but will go immediately to the Recycle Hold Timer  
if the A/C System is empty. The following matrix outlines the most commonly used options that can be programmed:  
Recover/Recycle  
Deep Vacuum  
Vacuum Leak Check  
Add Oil  
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
Charge  
X
X
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETUP  
1
2
3
4
5
6
Low Pressure Gauge  
Keypad  
7
8
9
Oil Charge - High Side  
Red Hose - High Side  
Blue Hose - Low Side  
13 Fill Port  
14 Refrigerant Cylinder  
15 Yellow Hose w/Anti-blowback  
16 Oil Drain Pressure Switch  
17 Oil Drain  
Power Switch  
High Pressure Gauge  
Display  
10 Oil Charge - Low Side  
11 Oil Charge Bottle  
Attention Light  
12 High/Low Charge Selector  
18 Oil Measuring Cup  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
                                        
                                          
                                            
                                                                  
                                                                    
                                                                      
FILL CHARGE CYLINDER  
WEIGHT= XX.X LB  
#
AUTOMATIC?  
N N N EXTREMELY IMPORTANT N N N  
>>>>  
WEIGHT= XX.X LB  
Always connect Yellow Hose (15) to Cylinder (14) first and then connect  
other end of hose with anti-blowback valve to Fill Port (13) on AC880.  
#
FILL CYLINDER?  
Note: For large capacity or multiple A/C Systems where recharge will NOT  
be done between successive recoveries, it may be desirable to skip  
this procedure.  
ENTER  
1. Set up the AC880 as shown on Page 4 and then turn the Main Power Switch  
ON. An adapter is provided with the AC880 (R134a) which permits the Yellow  
Hose (15) to be attached to the 1/4 SAE Flare fitting that is on some cylinders  
of R134a refrigerant.  
CHECK HOSES  
#
START?  
ENTER  
Note: The AC880 uses 15.4 lbs (7 Kg) of refrigerant when Filling the first  
time. If the Refrigerant Cylinder (14) is emptied, the AC880 will  
appear to stop filling (the Weight will stop rising) and will stay in  
this condition until the RESET key is pressed.  
WEIGHT= XX.X LB  
COMPRESSOR ON  
2. Using the Keypad, press the “Up Arrow” key four times to display “WEIGHT=  
XX.X LB” “FILL CYLINDER? #” and press the ENTER key. The Display will  
read “CHECK HOSES” “START? #”.  
FILL COMPLETE  
3. Open the LIQUID Valve on the Refrigerant Cylinder (14) connected to the Fill  
Port (13) with the Yellow Hose (15).  
FILLED= XX.X LB#  
4. Press the ENTER key when ready to start filling the AC880.  
ENTER  
*
The Display will read “WEIGHT=XX.X LB” “COMPRESSOR ON”. When the  
level is approximately 13 lbs (6 kg), 75 percent of the full capacity, the AC880  
will turn OFF, the Display will read “FILL COMPLETE” “FILLED= XX.X LB #”  
(the amount of refrigerant removed from the cylinder) and the Attention Light  
will turn ON. Close the Liquid Valve on the Refrigerant Cylinder.  
HIGH PRESSURE  
SEE MANUAL  
Note: Press the RESET button on the Keypad to stop the  
Fill Cylinder procedure at any time.  
**  
CYLINDER FULL  
5. Press the ENTER key to return to the Main Menu.  
GO TO CHARGE  
#
*
While filling the Charging Cylinder, this screen will display periodically  
concurrent with the Attention Light turning ON. This is normal and  
nothing to be concerned about. The screen should revert to normal after  
a few seconds.  
** This screen will display when the Charging Cylinder fills to capacity,  
approximately 17.5 lbs (8 Kg). If this occurs, the weight can be lowered  
using the Charge procedure on Page 9 before the AC880 can be used  
to recover more refrigerant. Press the ENTER key to return to the Main  
Menu.  
PROBLEMS ?  
Refer to Page 18 should  
problems be encountered using  
the Fill Cylinder procedure.  
Note:  
The AC880 Charging Cylinder can also be filled from the GAS or  
VAPOR side of a cylinder by following the Recover/Recycle  
procedure on Page 6.  
Pressure differential between  
the cylinder of new refrigerant  
and the internal AC880 charge  
cylinder greatly affect the  
efficiency and speed of the Fill  
Charge Cylinder procedure.  
Note:  
The AC880 will use 1.1 lb (0.5 Kg) more refrigerant than the  
displayed value the very first time it is used or after performing  
a Calibration Procedure in order to prime the internal  
components.  
Note:  
The Yellow Hose (15) can be removed from the Fill Port (13) and  
connected to either the Blue or Red Hose connection port on the  
rear of the AC880 to recover the refrigerant left in the Yellow  
Hose (15) using the Recover/Recycle procedure on Page 6.  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RECOVER/RECYCLE  
WEIGHT= XX.X LB  
1. Set up the AC880 and turn the Main Power Switch ON.  
#
AUTOMATIC?  
2. Attach the Red and Blue Hoses to the A/C System per the vehicle  
manufacturer's instructions, open the Red and Blue Hose Valves.  
>
3. Using the Keypad, press the “Up Arrow” key one time to display “WEIGHT=  
XX.X LB” “RECYCLE? #” and press the ENTER key. The Display will read  
“RECYCLE HOLD” “TIME XX MIN #”.  
WEIGHT= XX.X LB  
#
RECYCLE?  
The Recycle Hold Time is the amount of time that the AC880 waits for “out-  
gassing” or for the pressure in the A/C System to rise enough to automatically  
restart the recovery process. The minimum value is two minutes. The value  
entered is stored in memory and displays as the default value the next time the  
procedure is used.  
ENTER  
RECYCLE HOLD  
TIME XX MIN  
#
4. Press the “Up Arrow” key to change the value of the field. Press the “Right  
Arrow” key to change to a different field. Press the ENTER key to accept the  
value. The Display will then read “CHECK HOSES” “START? #”.  
><ENTER  
CHECK HOSES  
5. Press the ENTER key to start recovering and recycling with the AC880.  
#
START?  
The Display will read the “WEIGHT= XX.X LB” “COMPRESSOR ON”. The  
AC880 will recover and recycle refrigerant from the A/C System and  
automatically cycle OFF when a vacuum is sensed. This vacuum level can be  
seen on the Low Pressure Gauge. The Display will read “WEIGHT= XX.X LB”  
“COMPRESSOR OFF”  
ENTER  
WEIGHT= XX.X LB  
COMPRESSOR ON  
A small quantity of refrigerant will probably remain in the A/C System as  
observed by an increasing pressure on the Low Pressure Gauge. The AC880  
will automatically cycle ON to continue recovering refrigerant if pressure rises  
to a preset level. This automatic cycling will repeat, resetting the Recycle Hold  
Timer each time. When the AC880 remains OFF for the duration of the Recycle  
Hold Timer value entered in Step 4 the Display will read “AMOUNT  
RECYCLED=” “XX.X LB #” from the A/C System and the Attention Light will turn  
ON.  
WEIGHT= XX.X LB  
COMPRESSOR OFF  
6. Close the Red and Blue Hose Valves and disconnect the hoses from the A/C  
System.  
AMOUNT RECYCLED=  
7. Press the ENTER key. The Display will read “DRAIN RECOVERED OIL NOW!”.  
Drain any recovered oil using the Drain Recovered Oil procedure on Page 7.  
XX.X LB#  
8. Press the ENTER key to return to the Main Menu.  
ENTER  
*
This screen will display if there is an internal fault. Turn the AC880 Main  
Power Switch OFF. Contact RTI Technical Support.  
DRAIN RECOVERED  
OIL NOW!  
#
** This screen will display when the Charging Cylinder fills to capacity,  
approximately 17.5 lbs (8 Kg.) If this occurs, the Weight can be lowered  
using the Charge procedure on Page 9 before the AC880 can be used to  
recover more refrigerant. Press the ENTER key to return to the Main Menu.  
ENTER  
*
HIGH PRESSURE  
SEE MANUAL  
**  
CYLINDER FULL  
GO TO CHARGE  
#
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DRAIN RECOVERED OIL  
Oil is separated from the recovered refrigerant and MUST be removed following  
EACH Recover/Recycle procedure to determine the amount (if any) necessary to  
add into the A/C System as follows:  
Note: The AC880 must be connected to power source. Drain Recovered Oil  
may be done while the AC880 Vacuum Pump is ON.  
1. Press and hold the Oil Drain Re-pressurization Switch (16) for 5 seconds and  
then release it.  
2. Slowly open the Oil Drain Valve (17) to drain any oil which may have been  
removed from the A/C System.  
Unless the A/C System had previously been overfilled, the AC880 will typically  
not remove enough oil to make replenishment necessary.  
3. Close the Oil Drain Valve (17).  
4. Press and hold the Oil Drain Re-pressurization Switch (16) for 5 seconds. This  
permits any residual Non-Condensable Gas to be re-circulated for reprocessing  
during the next recycle procedure.  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DEEP VACUUM  
WEIGHT= XX.X LB  
1. Set up the AC880 and turn the Main Power Switch ON.  
AUTOMATIC?  
#
2. Attach the Red and Blue Hoses to the A/C System per the vehicle  
manufacturer's instructions and open the Red and Blue Hose Valves.  
>>  
WEIGHT= XX.X LB  
3. Using the Keypad, press the “Up Arrow” key two times to display “WEIGHT=  
XX.X LB” “VACUUM? #” and press the ENTER key. The Display will read  
“ENTER VACUUM” “TIME XX MIN #”.  
VACUUM?  
#
* This screen will display if the AC880 senses a pressure in either the High or Low  
Pressure Hoses. When this occurs, the A/C System must be emptied using the  
Recover/Recycle procedure on Page 6. Press the ENTER key to return to the  
Main Menu.  
ENTER  
*
A/C HAS PRESSURE  
4. Press the “Up Arrow” key to change the value of the field. Press the “Right  
Arrow” key to change to a different field. The value entered must be greater than  
zero. Press the ENTER key to accept the value. The Display will read  
“PERFORM LEAK” “TEST? Y/N#”.  
GO TO RECYCLE  
#
ENTER  
5. Press the “Right Arrow” key to move the cursor between Y and N to select  
whether or not the AC880 pauses at the end of Vacuuming so that a vacuum  
leak can be detected in the A/C System. Press the ENTER key to accept the  
Yes or No choice. The choice entered is stored in memory and comes up as the  
default the next time the procedure is used. The Display will read “ADD OIL?  
Y/N#”.  
ENTER VACUUM  
TIME XX MIN  
#
><ENTER  
PEFORM LEAK  
6. Press the “Right Arrow” key to move the cursor between Y and N to select  
whether or not the AC880 pauses at the end of Vacuuming (or Vacuum Leak  
Checking) to allow the Adding of Oil to the A/C System. Press the ENTER key  
to accept the Yes or No choice. The choice entered is stored in memory and  
comes up as the default the next time the procedure is used. The Display will  
read “START? #”.  
TEST?  
Y/N#  
Y/N#  
#
<ENTER  
7. Press the ENTER key to start the Vacuum Pump.  
ADD OIL?  
The Vacuum Pump will turn On, the Display will read “TIME LEFT=XX MIN”  
“PUMP ON” and the minutes remaining will count down on the Display. The  
Vacuum Pump will turn OFF when the Display reads zero minutes.  
<ENTER  
8. If a Vacuum Leak Check was selected by choosing Y in Step 5 the Display will  
read “PUMP OFF XX MIN” “CONTINUE? #” and the Attention Light will turn ON.  
The elapsed time since the Vacuum Pump turned OFF will count up on the  
Display. An increasing pressure on the Low Pressure Gauge is evidence of a  
vacuum leak in the A/C System. Press the ENTER key to return to the Main  
Menu or to Add Oil if selected in Step 6.  
START?  
ENTER  
TIME LEFT=XX MIN  
PUMP ON  
9. If Add Oil was selected by choosing Y in Step 6 the Display will read “ADD OIL  
NOW” “CONTINUE? #”, and the Attention Light will turn ON. Refer to Figure 4  
and connect Oil Charge Bottle (11) to Oil Charge High Side (7) or Oil Charge  
LowSide(10)basedonthevehiclemanufacturer’sinstructionsforcharginghigh  
or low side. Open the valve on the Oil Charge Bottle (11), and leaving it open  
until the correct amount of oil has left the Oil Charge Bottle. Close the valve on  
the Oil Charge Bottle and press the ENTER key to return to the Main Menu.  
PUMP OFF XX MIN  
CONTINUE?  
#
#
ENTER  
ADD OIL NOW  
CONTINUE?  
ENTER  
Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CHARGE  
WEIGHT= XX.X LB  
1. Set up the AC880 and turn the Main Power Switch ON.  
AUTOMATIC?  
#
2. Attach the Red and Blue Hoses to the A/C System per the vehicle  
manufacturer's instructions and open the Red and Blue Hose Valves.  
>>>  
WEIGHT= XX.X LB  
3. Determine the refrigerant capacity of the A/C System to be charged.  
Note:  
1 oz = 0.02835 Kg  
1 Lb = 0.45359 Kg  
CHARGE?  
#
4. Using the Keypad, press the “Up Arrow” key three times to display “WEIGHT=  
XX.X LB” “CHARGE? #” and press the ENTER key. The Display will read  
“ENTER CHARGE” “AMOUNT= XX.X LB #”.  
ENTER  
ENTER CHARGE  
5. Press the “Up Arrow” key to change the value of the field. Press the “Right  
Arrow” key to change to a different field. The value entered must be greater than  
zero. Press the ENTER key to accept the value. The Display will read “CHECK  
HIGH-LOW” “CHARGE SWITCH #”.  
AMOUNT= XX.X LB#  
><ENTER  
*
This screen will display if the AC880 Charge Cylinder contains less  
refrigerant than the entered value. When this occurs, the charging Cylinder  
should be filled using the Fill Cylinder procedure on Page 5. Press the  
ENTER key to return to the Main Menu.  
*
LOW LEVEL GO TO  
,
FILL CYLINDER  
#
6. Based on the vehicle manufacturer’s instructions, choose Charging through  
either the High Pressure Hose (preferred) or the Low Pressure Hose bypressing  
the top or bottom (respectively) of the High-Low Charge Selector Switch (12).  
ENTER  
CHECK HIGH-LOW  
Note: Do not turn on the A/C System. SAE compliant refrigerant handling  
stations, like the AC880, supply refrigerant in the liquid phase. Adding  
liquid refrigerant to a running A/C System may cause immediate A/C  
compressor failure.  
CHARGE SWITCH  
#
ENTER  
7. Press the ENTER key to start charging.  
WEIGHT= XX.X LB  
CHARGING  
The Display will read “WEIGHT= XX.X LB” “CHARGING” as refrigerant leaves  
the Charging Cylinder. The weight displayed will increase from zero to the  
Charge Amount entered in Step 5 plus a one ounce (0.03 KG) Over Charge set  
at the factory to compensate for hose loss. (See Set Over Charge Amount on  
Page 13 to change the default value.) When the AC880 has finished, the  
Display will read “CHARGE COMPLETE” “EVAC HOSES” and the Attention  
Light will turn ON.  
CHARGE COMPLETE  
EVAC HOSES  
#
8. Press the ENTER key to return to the Main Menu. The A/C System can now be  
turned on and tested by monitoring the High and Low Pressure Gauges.  
ENTER  
9. Close the Red and Blue Hose Valves, disconnect them from the A/C System  
and go to Page 6 (Recover/Recycle) to Evacuate refrigerant from the Hoses.  
Page 9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUTOMATIC  
WEIGHT= XX.X LB  
1. Set up the AC880 and turn the Main Power Switch ON.  
#
AUTOMATIC?  
2. Attach the Red and Blue Hoses to the A/C System per the vehicle  
manufacturer's instructions and open the Red and Blue Hose Valves.  
ENTER  
3. Determine the refrigerant capacity of the A/C System to be charged.  
RECYCLE HOLD  
Note:  
1 oz = 0.02835 Kg  
1 Lb = 0.45359 Kg  
TIME XX MIN  
#
#
4. Using the Keypad, press the ENTER key when the Display reads “WEIGHT=  
XX.X LB” “AUTOMATIC? #” (this is the default screen of the Main Menu.) The  
Display will read “RECYCLE HOLD” “TIME XX MIN #”.  
><ENTER  
ENTER VACUUM  
The Recycle Hold Time is the amount of time that the AC880 waits for “out-  
gassing” or for the pressure in the A/C System being recovered to rise enough  
to automatically restart the recovery process. The minimum value is two  
minutes. The value entered is stored in memory and displays as the default the  
next time the procedure is used.  
TIME XX MIN  
><ENTER  
PEFORM LEAK  
5. Press the “Up Arrow” key to change the value of the field. Press the “Right  
Arrow” key to change to a different field. Press the ENTER key to accept the  
value. The Display will read “ENTER VACUUM” “TIME XX MIN #”.  
TEST?  
Y/N#  
Y/N#  
6. Press the “Up Arrow” key to change the value of the field. Press the “Right  
Arrow” key to change to a different field. Press the ENTER key to accept the  
value. The Display will read “PERFORM LEAK” “TEST? Y/N#”.  
<ENTER  
7. Press the “Right Arrow” key to move the cursor between Y and N to select  
whether or not the AC880 pauses at the end of Vacuuming so that a vacuum  
leak can be detected in the A/C System. Press the ENTER key to accept the  
Yes or No choice. The choice entered is stored in memory and displays as the  
default the next time the procedure is used. The Display will read “ADD OIL?  
Y/N#”.  
ADD OIL?  
<ENTER  
ENTER CHARGE  
8. Press the “Right Arrow” key to move the cursor between Y and N to select  
whether or not the AC880 pauses at the end of Vacuuming (or Vacuum Leak  
Checking) to allow the Adding of Oil to the A/C System. Press the ENTER key  
to accept the Yes or No choice. The choice entered is stored in memory and  
displays as the default the next time the procedure is used. The Display will read  
“ENTER CHARGE” “AMOUNT= XX.X LB#”.  
AMOUNT= XX.X LB#  
><ENTER  
*
LOW LEVEL GO TO  
,
9. Press the “Up Arrow” key to change the value of the field. Press the “Right  
Arrow” key to change to a different field. The value entered must be greater than  
zero. Press the ENTER key to accept the value. The Display will read “CHECK  
HIGH-LOW” “CHARGE SWITCH #”.  
FILL CYLINDER  
#
#
#
ENTER  
CHECK HIGH-LOW  
*
This screen will display if the AC880 Charge Cylinder contains less refrigerant  
than the entered value. When this occurs, the charging Cylinder should be  
filled using the Fill Cylinder procedure on Page 5. Press the ENTER key to  
return to the Main Menu.  
CHARGE SWITCH  
ENTER  
10. Based on the vehicle manufacturer’s instructions, choose Charging through  
either the High Pressure Hose (preferred) or the LowPressure Hose bypressing  
the top or bottom of the High-Low Charge Selector Switch (12). Press the  
ENTER key when finished programming. The Display will read “CHECK  
HOSES” “START? #”.  
CHECK HOSES  
START?  
ENTER  
Note: Do Not Turn On The A/C System. SAE compliant refrigerant  
handling stations, like the AC880, supply refrigerant in the liquid  
phase. Adding liquid refrigerant to a running A/C System maycause  
immediate A/C compressor failure.  
WEIGHT= XX.X LB  
COMPRESSOR ON  
11. Press the ENTER key to start the Automatic sequence.  
Page 10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AUTOMATIC (continued)  
WEIGHT= XX.X LB  
COMPRESSOR OFF  
The Display will read the “WEIGHT= XX.X LB” “COMPRESSOR ON”. The  
AC880 will recover and recycle refrigerant from the A/C System and  
automatically cycle OFF when a vacuum is sensed. This vacuum level can be  
seen on the Low Pressure Gauge. The Display will read “WEIGHT= XX.X LB”  
“COMPRESSOR OFF”  
*
HIGH PRESSURE  
SEE MANUAL  
A small quantity of refrigerant will probably remain in the A/C System as  
observed by an increasing pressure on the Low Pressure Gauge. The AC880  
will automatically cycle ON to continue recovering refrigerant if pressure rises  
to a preset level. This automatic cycling will repeat resetting the Recycle Hold  
Timer each time. If a Vacuum Time greater than zero minutes was entered in  
Step 6, the Vacuum Pump will turn ON, the Display will read “TIME LEFT=XX  
MIN” “PUMP ON” and the minutes remaining will count down on the Display.  
The Vacuum Pump will turn OFF when the Display reads zero minutes.  
**  
CYLINDER FULL  
GO TO CHARGE  
#
12. Drain any recovered oil using the Drain Recovered Oil procedure on Page 7.  
TIME LEFT=XX MIN  
PUMP ON  
* This screen will display if there is an internal fault. Turn the AC880 Power  
Switch OFF. Contact RTI Technical Support.  
** This screen will display when the Charging Cylinder fills to capacity,  
approximately 17.5 lbs (8 Kg). If this occurs, the weight can be lowered using  
the Charging procedure on Page 9 before the AC880 can be used to recover  
more refrigerant. Press the ENTER key to return to the Main Menu.  
PUMP OFF XX MIN  
13. If a Vacuum Leak Check was selected by choosing Y in Step 7 the Display will  
read “PUMP OFF XX MIN” “CONTINUE? #” and the Attention Light will turn ON.  
The elapsed time since the Vacuum Pump stopped will count up on the Display.  
An increasing pressure on the Low Pressure Gauge is evidence of a vacuum  
leak in the A/C System. Press the ENTER key to continue with the Automatic  
sequence or RESET to return to the Main Menu.  
CONTINUE?  
#
#
ENTER  
ADD OIL NOW  
CONTINUE?  
14. If Add Oil was selected by choosing Y in Step 8 the Display will read “ADD OIL  
NOW” “CONTINUE? #”, and the Attention Light will turn ON. Refer to Figure 4  
and connect Oil Charge Bottle (11) to Oil Charge High Side (7) or Oil Charge  
LowSide(10)basedonthevehiclemanufacturer’sinstructionsforcharginghigh  
or low side. Open the valve on the Oil Charge Bottle (11), and leaving it open  
until the correct amount of oil has left the Oil Charge Bottle. Close the valve on  
the Oil Charge Bottle and press the ENTER key to continue.  
ENTER  
WEIGHT= XX.X LB  
CHARGING  
15. If a Charge Amount greater than zero pounds was entered in Step 9 the Display  
will read “WEIGHT= XX.X LB” “CHARGING”as refrigerant leaves the Charging  
Cylinder. The weight displayed will be increasing from zero to the charge  
amount entered plus a one ounce (0.03 KG) “Over Charge” set at the factory to  
compensate for hose loss. (See Setting Over Charge Amount on Page 13 to  
change the default value.) When the AC880 has finished, the Display will read  
“RECYCLED=XX.X LB” “EVAC HOSES” and the Attention Light will turn ON.  
RECYCLED=XX.X LB  
EVAC HOSES  
#
#
ENTER  
DRAIN RECOVERED  
16. Press the ENTER key. The Display will read “DRAIN RECOVERED OIL NOW!”.  
Drain any recovered oil using the Drain Recovered Oil procedure on Page 7.  
OIL NOW!  
ENTER  
17. Press the ENTER key to return to the Main Menu. The A/C System can now be  
turned on and checked by monitoring the High and Low Pressure Gauges.  
18. Close the Red and Blue Hose Valves, disconnect them from the A/C System  
and go to Page 6 (Recover/Recycle) to Evacuate refrigerant from the Hoses.  
Page 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ACCESS STORED DATA  
WEIGHT= XX.X LB  
1. Set up the AC880 and turn the Main Power Switch ON.  
#
AUTOMATIC?  
2. Using the Keypad, press the “Up Arrow” key five times to display  
“WEIGHT= XX.X LB” “SETUP? #” and then press the ENTER key. The  
Display will read “FILTER HOURS=” “XX.X HOURS”.  
>>>>>ENTER  
WEIGHT= XX.X LB  
See the Filter Maintenance section of the manual, Page 14, for the  
procedure to change the filters. The normal Filter Change Interval is after  
every 25 hours.  
#
SETUP?  
ENTER  
Note: Press and hold the “Right Arrow” key and press the RESET key  
FILTER HOURS=  
to remove the “CHANGE FILTERS #” message.  
XX.X HOURS  
3. Press the “Up Arrow” key. The Display will read “TOTAL RECYCLED=”  
“XXXX.X KG”.  
>
4. Press the “Up Arrow” key. The Display will read “TOTAL CHARGED=”  
“XXXX.X KG”.  
TOTAL RECYCLED=  
5. Press the “Up Arrow” key to return to the Main Menu.  
XXXX.X KG  
>
TOTAL CHARGED=  
XXXX.X KG  
>
Page 12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SET OVER CHARGE AMOUNT  
WEIGHT= XX.X LB  
1. Remove the front panel of the AC880.  
#
AUTOMATIC?  
2. Set up the AC880 as shown on Page 4 and then turn the Main Power Switch  
ON. Refer to the figure below to locate the Access Hole (on the metal circuit  
board cover) to the Calibration Switch.  
>>>>> ENTER  
WEIGHT= XX.X LB  
3. Remove the plastic Calibration Tool from the mounting hole of the circuit board  
cover.  
#
SETUP?  
4. Using the Keypad, press the “Up Arrow” key five times to display “WEIGHT=  
Calibration Switch  
XX.X LB” “SETUP? #”.  
WEIGHT= XX.X LB 5. GENTLY press the Calibration Switch with the Calibration Tool. The Display will  
read “WEIGHT= XX.X LB” “CHARGING”.  
CHARGING  
6. Press the “Up Arrow” key. The Display will read “OVER CHARGE” “AMOUNT=  
X.XX KG#”.  
>
7. Press the “Up Arrow” key to change the value of the field. Press the “Right  
OVER CHARGE  
Arrow” key to change to a different field. The value entered will be stored until  
this procedure is run again and a new value is entered. Press the ENTER key  
to accept the value. The Display will then return to the Main Menu.  
AMOUNT= X.XX KG#  
Note: 1 oz = 0.02835 Kg  
1 Lb = 0.45359 Kg  
><ENTER  
8. Replace the front panel of the AC880.  
Calibration Tool Part No. 360-81214-00  
Page 13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SCHEDULED MAINTENANCE  
DAILY...  
Check the oil level in the Vacuum Pump while the pump is running. The Vacuum Pump Oil Level Sight Glass is visible through  
a hole in the Lower Rear Panel of the AC880. The oil level should be at the “half-way” point of the glass. If oil is not visible call  
Technical Support at 800-468-2321 (Ext. 259).  
MONTHLY...  
Check the oil level in the Compressor while the motor is not running. The Compressor Oil Level Sight Tube is on the left side  
of the lower section of the AC880 as viewed from the front. Remove the front panel from the AC880. The oil level should be  
approximately one half inch high in the Sight Tube. If oil is not visible or is above the top of the Sight Tube call Technical  
Support at 800-468-2321 (Ext. 259).  
Clean the Condenser to maintain high efficiency performance of the AC880. Disconnect power and remove the lower rear  
perforated panel and blow compressed air through the cooling fins of the Condenser to remove any debris. Do not bend the  
fins on the Condenser coils. Air flow will be restricted causing damage to the AC880. Replace the panel before applying power  
to the AC880.  
FILTER MAINTENANCE  
The AC880 automatically keeps track of Compressor Run Time. The Display will read “CHANGE FILTERS #” after every 25  
hours every time the program returns to the Main Menu or whenever the AC880 is turned on as a reminder to change the filters.  
Press ENTER # to go to the Main Menu.  
The “INLET” Combo Filter (left side) must be changed after every 25 hours of operation. RTI part number 026-80077-00.  
The “OUTLET” Combo Filter (right side) must be changed after every 50 hours of operation. RTI part number 026-80069-00.  
The Hour Counter is reset when the “CHANGE FILTERS #” message is cleared. Record the filter changes performed to track  
when only the “INLET” Combo Filter is changed versus when both are changed.  
Change the filters as described below:  
1. Remove front panel to service the Combo Filters.  
2. Disconnect Flare Fittings from top and bottom of filters.  
3. Remove mounting nuts and filters.  
4. Transfer filter insulation material to new filter as applicable.  
5. Install new Combo Filters using hardware removed in Step 3.  
6. Connect Flare Fittings to top and bottom of filters.  
7. Check for leaks and repair as necessary.  
8. Replace front panel.  
9. Go to Page 12, Accessing Stored Data, for instructions on how to reset the “CHANGE FILTERS #” message.  
Page 14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS IDENTIFICATION  
P/N  
DESCRIPTION  
1
2
3
4
5
6
7
8
9
360-81555-00 Manifold Assy 880  
120V  
024-80037-00 Contactor ½ HP  
(120V) 3NO/1NC  
024-80066-00 Rocker Switch SPDT  
Visired Non-lighted  
360-80369-02 D/P Switch R134A  
360-81195-03 Vacuum Pump Assy JB  
360-81314-00 Low Pressure Switch  
3 psig-15in Hg SPDT  
360-81221-01 Charging Cylinder Assy  
8 Kg 120V Htr  
024-80035-00 Rocker Switch SPST  
(mom-on) Non-lighted  
360-81196-03 Check Valve Assy  
1/4 FFL > 6/4 Tube  
10 360-81337-01 Heater Assy 120V  
11 031-80001-00 Load Cell 35Kg (with  
Support Assy)  
12 360-81344-00 Condenser/Fan Assy  
120V  
Page 15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS IDENTIFICATION  
P/N  
DESCRIPTION  
1
2
3
4
5
026-80077-00 Combo Filter 3/8 Flare  
(Long)  
360-81192-00 Compressor Inlet Tube  
Assy  
360-81197-00 Accumulator Assy  
360-81356-01 Compressor Assy 780  
120V  
026-80069-00 Combo Filter 3/8 Flare  
(Short)  
6
7
360-81292-00 Solenoid MOV Sub-  
Assy 120V  
360-81307-00 High Pressure Switch  
261 Psig SPDT w/Gask  
Page 16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS IDENTIFICATION  
P/N  
DESCRIPTION  
1
024-80040-00 Rocker Switch SPDT  
(on-on) Amber 125V  
2
3
024-80060-01 Circuit Board 120V  
026-80065-03 Gauge 30"-120 Psig  
1/4 MFL 3.5"  
4
5
6
7
025-80128-00 Lamp Holder w/Clear  
Bulb 120V  
025-80127-00 Clear Bulb Bayonet  
Base 120V  
025-80131-00 Lens Assy Amber  
026-80071-03 Gauge 0-500 Psig  
1/4 MFL 3.5"  
Page 17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING FILL CYLINDER PROCEDURE  
1) The cylinder of new refrigerant should be at ambient temperature or greater for best performance of the Fill Cylinder  
procedure. Make sure the cylinder was not recently moved from an air-conditioned storage room to a warm work area.  
Place the cylinder on a block of wood if necessary to elevate it from a cool concrete floor. Application of a heat belt to  
the cylinder will greatly enhance the speed.  
2) Verify that the cylinder of new refrigerant (14) is up-side-down as shown in the figure on page 4 and that the cylinder  
valve is open.  
3) If filling the Charge Cylinder from a DOT Cylinder, make sure the hose is connected to the liquid port and the DOT  
Cylinder is right-side-up.  
4) If the yellow hose (15) was connected to the Fill Port (13) the first time the AC880 was used, there may be excessive  
air in the AC880 Charge Cylinder. At least 4 lbs. of refrigerant must be recovered/recycled into the AC880 Charge  
Cylinder following the Recover/Recycle procedure on Page 6. During this process, the air in the AC880 Charge Cylinder  
will be automatically purged.  
5) Verify that the cylinder of new refrigerant has liquid refrigerant in it by shaking the cylinder or weighing the contents. A  
minimum of 4 lbs. of liquid is required.  
6) Verify that the Yellow Hose (15) is connected correctly from the Cylinder (14) to the  
Fill Port (13). On an R12 AC880, the Fill Port is equipped with a valve core so a  
depressor must be present in the hose end (see figure). The Yellow Hose (15) has  
a shut-off valve on one end (instead of an anti-blowback valve) which must be  
connected to the Fill Port (13). The depressor in the hose may be adjustable, so  
extend the depth of the depressor by using needle-nose pliers.  
7) Remove the valve core from the Fill Port (13) using a valve core remover.  
There may be a machine fault if the above steps do not result in a successful  
increase of weight shown on the display after running the Fill Cylinder  
procedure for a minimum of 15 minutes.  
Contact RTI Technical Support at 800-468-2321 (Ext.259) for help.  
Page 18  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sennheiser Microphone SDC 8000 CC User Manual
Sennheiser Stereo Receiver AC 3200 User Manual
Shure Headphones miniature microphone User Manual
SIIG TV Mount 04 0676A User Manual
Sony Car Stereo System MEX BT39UW User Manual
Sony Cassette Player CFD S100 User Manual
Sony CRT Television KV VF21M40 User Manual
Sony MP3 Player ZS D5 User Manual
Summit Refrigerator 225D6783P011 User Manual
SUPER MICRO Computer Computer Hardware H8SCM User Manual