R
FU-Z31E
*Plasmacluster is a trademark of Sharp
Corporation.
*Plasmacluster adalah Merek Dagang dari
Sharp Corporation.
AIR PURIFIER
OPERATION MANUAL
PETUNJUK PENGOPERASIAN
AIR PURIFIER
Free standing type
Tipe Berdiri
No. Reg. : 03/DJ-ILMEA/MG/I/2000
Download from Www.Somanuals.com. All Manuals Search And Download.
ENGLISH
FEATURES
CONTENTS
"Plasmacluster" technology
.....
IMPORTANT SAFETY INSTRUCTIONS
E-2
Plasmacluster technology uses plas-
ma discharge to produce and release
the same positive and negative ions
as those found in nature ("Plasma-
cluster ions").
• WARNING ....................................................
• CAUTIONS CONCERNING OPERATION ...
• INSTALLATION GUIDELINES......................
• FILTER GUIDELINES ..................................
E-2
E-3
E-3
E-3
This is a unique air cleaning technolo-
gy of the SHARP CORPORATION for
breaking down and inactivating such
potential allergens as the fecal matter
or corpses of aerial mites*1, viruses *2
and mould and bacteria *3 suspended
in the air, and has been substantiated
by third-party organisations both in
Japan and overseas.
...............................................
PART NAMES
E-4
• MAIN UNIT DISPLAY ...................................
• ILLUSTRATIVE DIAGRAM..........................
• INCLUDED...................................................
• BACK............................................................
E-4
E-4
E-5
E-5
............................................
PREPARATION
E-6
E-6
• FILTER INSTALLATION ...............................
When there is a high density of Plas-
macluster ions in the air, the smell of
cigarette smoke trapped in curtains
or sofas is removed in about 80 min-
utes*4, and when clothing is hung in
a place exposed to the direct air ex-
pelled from the unit generating Plas-
macluster ions, the smell of sweat is
reduced to a virtually imperceptible
level in one night (about 6 hours).
.................................................
OPERATION
E-8
E-8
• MAIN UNIT OPERATION .............................
.....................
CARE AND MAINTENANCE
E-9
E-9
E-9
• BACK PANEL AND SENSOR.......................
• UNIT.............................................................
• FILTER REPLACEMENT GUIDELINES.....
E-10
..............................
TROUBLESHOOTING
E-11
E-12
......................................
SPECIFICATIONS
*1 Graduate School of Advanced Sci-
ences of Matter, Hiroshima University,
Japan
Measurement of action on the poten-
tial allergens of aerial mites in (13m²)
*2 Retroscreen Virology, Ltd., London, UK
Measurement of ratio of viruses elimi-
nated from the air in a 1m³ box
*3 Ishikawa Health Service Association,
Japan
Measurement of aerial mold and bac-
teria with an air sampler (13m²)
*4 Japan Spinners Inspecting Foundation,
Japan
Evaluation of deodorizing effect on
odor-imbued fragments of cloth
Thank you for purchasing the SHARP Air Puri-
fier. Please read this manual carefully for the
correct usage information. Before using this
product, be sure to read the section: “Important
Safety Instructions.”
After reading this manual, retain it in a conven-
ient location for future reference.
E-1
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPORTANT SAFETY INSTRUCTIONS
When using electrical appliances, basic safety precautions should be followed, including the
following:
- To reduce the risk of electrical shock, fire or injury to persons:
WARNING
• Read all instructions before using the unit.
• Use only a 220-240 volt outlet.
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet
is loosened.
• Periodically remove dust from the power plug.
• Do not insert fingers or foreign objects into the intake or air outlet.
• When removing the power plug, always hold the plug and never pull the cord.
Electrical shock and/or fire from short circuit may occur as a result.
• Do not remove the plug when your hands are wet.
• Do not use this unit near gas appliances or fireplaces.
• Remove the power plug from the wall outlet before cleaning the unit and when not using the
unit.
Electrical shock from bad insulation and/or fire from short circuit may occur as a result.
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent,
Sharp Approved Service Centre or similarly qualified person in order to avoid a hazard.
• Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,
sparks from lit cigarettes, chemical fumes in the air or in very high humidity conditions, such as a
bathroom.
• Be cautious when cleaning the unit. Corrosive cleansers may damage the exterior.
• Only Sharp Approved Service Centre should service this air purifier. Contact the nearest Service
Centre for any problems, adjustments, or repairs.
• This appliance is not intended for use by persons (including children) with reduced physical, sen-
sory or mental capabilities, or lack of experience and knowledge, unless they have been given su-
pervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
- Radio or TV Interference
NOTE
If this air purifier should cause interference to radio or television reception, try to correct the interfer-
ence by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the unit and radio/TV receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-
nected.
• Consult the dealer or an experienced radio/TV technician for help.
E-2
Download from Www.Somanuals.com. All Manuals Search And Download.
CAUTIONS CONCERNING OPERATION
• Do not block the intake and/or air outlet.
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into
contact with steam.
• Do not lay the unit down when using.
• Always hold the handle on both sides of the unit when moving it.
Holding the back panel when carrying may cause it to detach, thus dropping the unit and resulting
in bodily injury.
• Do not operate the unit without the filter.
• Do not wash and reuse the filter .
Not only does it not improve filter performance, but also may cause electrical shock or malfunction.
• Clean the exterior with a soft cloth only.
The unit surface may be damaged or cracked.
In addition, the sensors may malfunction as a result.
INSTALLATION GUIDELINES
• During the operation of the product, please place the unit at least 2 m away from equipment
utilizing electrical waves such as televisions, radios or wave clocks.
• Avoid locations where curtains, etc., come into contact with the intake or air outlet.
Curtains, etc., may become dirty or a malfunction may occur.
• Avoid locations where the unit is exposed to condensation, due to rapid temperature
changes.
(If it is unavoidable please allow unit to stand for 1 hour before switching on.)
(Use under appropriate conditions between 0 and 35˚C in the room.)
• Place on a stable surface with sufficient air circulation.
When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.
• Do not install when there is a possibility of soot, such as in a kitchen, etc.
The unit surface may crack as a result.
• Leave about 60cm of space from the wall.
The wall behind the air outlet may become dirty as time passes. When using the unit for extended
period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty.
In addition, periodically clean the wall.
FILTER GUIDELINES
• Follow the instructions in this manual for correct care and maintenance of the filter.
Use only filter designed for this product.
E-3
Download from Www.Somanuals.com. All Manuals Search And Download.
PART NAMES
MAIN UNIT DISPLAY
POWER ON/OFF Button
Plasmacluster Ion ON/OFF Button
MODE Button
Odour
Plasmacluster
Ion ON/OFF
Indicator Light
Sensor
Fan Speed
Indicator Lights
CLEAN SIGN
The odour sensor continuosly monitors
the air and changes colour depending
on air punity.
Green Orange
Red
Clean Very Impure
ILLUSTRATIVE DIAGRAM
Handle
Main Unit
E-4
Download from Www.Somanuals.com. All Manuals Search And Download.
INCLUDED
• Operation manual
BACK
Handle
Tab
Filter
(Dust Collection / Deodorising Filter)
Date Label
Air Outlet
Back Panel
Air Inlet
Power Cord
Plug
(Shape of plug depends on country.)
E-5
Download from Www.Somanuals.com. All Manuals Search And Download.
Be sure to remove the power plug from the wall outlet.
PREPARATION
FILTER INSTALLATION
To maintain the quality of the filter, they are installed in the main unit and packed in
plastic bag. Be sure to remove the filter from the plastic bag before using the unit.
Tab
Remove the filter
1
Remove the Back Panel.
1
Pull the tab at the top of the Back Panel.
Remove the Filter from the
plastic bag.
2
Intall the filter
2
Place the Filter within the main unit.
1
Do not install the filter backwards or the unit will not operate properly.
E-6
Download from Www.Somanuals.com. All Manuals Search And Download.
Replace the Back Panel to the main unit.
2
Push until it clicks into place.
Fill in the usage start date on the Date Label.
3
Use the date as a guide for the filter replacement schedule.
Date Label
E-7
Download from Www.Somanuals.com. All Manuals Search And Download.
OPERATION
MAIN UNIT OPERATION
MODE Button
Plasmacluster Ion
ON/OFF Button
Fan Speed Indicator Lights
POWER ON/OFF
Button
Plasmacluster Ion Indicator Light
Power ON/OFF Button
• Press to start operation (short beep) and stop operation
(long beep)
• Plasmacluster Indicator Light and Fan Speed Indicator
Light turn on/off.
• Unless the power cord has been unplugged, the opera-
tions starts in the previous mode it was operated in.
MODE Button
• Press the MODE Button to select the desired fan speed.
Indicator Lights will show the fan speed currently select-
ed.
• The operation mode can be switched as below.
LOW operation
AUTO operation
The fan speed is automatically switched
(between HIGH and LOW) depending on the
amount of impurities in the air. The sensors
detect impurities for efficient air purfication.
The unit will operate quietly using
minimal air intake.
MAX operation
MEDIUM operation
The unit will operate at a fan speed
of MAX.
The unit will operate at a fan speed
of MEDIUM.
Plasmacluster Ion ON/OFF Button
Press the Plasmacluster Ion ON/OFF Button to turn
Plasmacluster Ion Mode ON and OFF.
When Plasmacluster Ion is ON, the Plasmacluster Ion
Indicator Light will turn on.(blue)
<When the CLEAN-SIGH is too bright>
Press the Plasmacluster Ion ON/OFF Button for 3 sec-
onds to switch the CLEAN-SIGN ON and OFF.
E-8
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE AND MAINTENANCE
To maintain optimum performance of this air purifier, please clean the unit including the filter
periodically.
When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet
hands. Electrical shock and/or bodily injury may occur as a result.
BACK PANEL and SENSORS
Whenever dust accumulates
on the unit or every 2 months
Care Cycle
Gently remove dust from the sensor opening and the back panel, using a vacuum
cleaner attachment or similar tool.
<When the back panel has stubborn dirt>
In case of heavy dirt, soak the back panel in water with a small amount of kitchen
detergent.
1
(Approx. 10min.)
(Avoid scrubbing the back panel hard when washing.)
Rinse the back panel repeatedly with clean water to remove
the solution residue.
2
Drip dry filter to remove excess water.
Back Panel
3
UNIT
Care Cycle Whenever dust accumulates on the unit or every 1 month
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are
allowed to remain, they may become difficult to remove.
Wipe with a dry, soft cloth
For stubborn stains or dirt, use a soft cloth dampened with warm water.
Do not use volatile fluids
Benzine, paint thinner, polishing powder, etc., may damage the surface.
Do not use detergents
Detergent ingredients may damage the unit.
E-9
Download from Www.Somanuals.com. All Manuals Search And Download.
CARE AND MAINTENANCE
FILTER REPLACEMENT GUIDELINES
Filter life vary depending on the room environment, usage, and location
of the unit.
If dust or odour persists, replace the filter.
(Refer to “Please read before operating your new Air Purifier”)
Guide for filter replacement timing
• The following filter life and replacement period is based on the condition of smoking 5
cigarettes per day and the dust collection/deodorization power is reduced by half compared
with that of new filter.
We recommend to replace the filter more frequently if the product is used in a condition sig-
nificantly severer than normal household use.
• Filter
About 2 years after opening
REPLACING THE FILTER
See page E-6,7 for directions on
1
how to install the filter when re-
placing.
Fill in the usage start date of the
filter on the Date Label.
2
Date Label
Replacement Filters
Model : FZ-Y30SFE
• Dust Collection / Deodorizing Filter : 1 unit
Dust Collection /
Deodorizing Filter
Please consult your dealer for purchase of replacement filter.
Disposal of Filter
Please dispose of the replaced filter according to the local disposal laws and regulations.
Filter materials :
• Filter : Polypropylene
• Frame : Polyester
• Deodorizer : Activated charcoal
E-10
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING
Before calling for service, please review the Troubleshooting chart below, since the problem may not
be a unit malfunction.
REMEDY (not a malfunction)
SYMPTOM
• Replace the filter if it appear to be heavily soiled.
(See E-10)
Odours and smoke are not
removed.
• The air could be impure at the time the unit was plugged in.
Unplug the unit, wait one minute, and plug the unit in again.
The Clean Sign illuminates
green even when the air is
impure.
• Sensor operation is affected if the odour sensor openings are
dirty or clogged. Gently clean the dust sensors.
(See E-9)
The Clean Sign illuminates
orange or red even when the
air is clean.
• Clicking or ticking sounds may be audible when the unit is gen-
erating Plasumacluster ions.
A clicking or ticking sound
is heard from the unit.
• Check to see if the filter are heavily soiled.
• Clean or replace the filter.
• Plasmacluster Air Purifiers emit small traces of ozone which
may produce an odour.
The discharged air has an
odour.
The unit does not operate
when cigarette smoke is in
the air.
• Is the unit installed in a location that is difficult for the sensor to
detect cigarette smoke?
• Are the dust sensor openings blocked or clogged?
(In this case, clean the openings.) (See E-9)
• Check to see if the Lights OFF Mode selected. If so, then press
the Plasmacluster Ion ON/OFF Button to activate the indicator
lights. (See E-8)
The Clean Sign are turned
off.
The Clean Sign lights
change colour frequently.
• The Clean Sign lights automatically change colours as impuri-
ties are detected by the odour sensor.
E-11
Download from Www.Somanuals.com. All Manuals Search And Download.
SPECIFICATIONS
FU-Z31E
220-240V 50/60Hz
MED
Model
Power supply
LOW
23W
60m3/hour
MAX
49W
180m3/hour
Fan Speed Adjustment
Rated Power
Fan
Speed
Operation
32W
120m3/hour
~21m2 *1
~13m2 *2
Fan Speed
Recommended Room Size
High density Plasmacluster ion recommended room size
Cord Length
2.0m
Dimensions
356mm(W)x180mm(D)x510mm(H)
Weight
5.0kg
Size of a room which is appropriate for operating the unit at maximum fan speed.
•It indicates the space where a certain amount of dust particles can be removed in 30
minutes(JEM1467).
*1
*2
Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the
center of the room (at a height of approximately 1.2 meters from the floor) when the product is
placed next to a wall and run at the MAX operation position.
In order to operate the electrical circuits while the power plug is inserted in the
wall outlet, this product consumes about 1.0W of standby power.
For energy saving, unplug the power cord when the unit is not in use.
Standby Power
The class of the HEPA filter by EN 1822 is H10.
E-12
Download from Www.Somanuals.com. All Manuals Search And Download.
SHARP CORPORATION
OSAKA, JAPAN
Printed in China
TINS-A420KKRZ 10C- CN
1