Sharp Air Cleaner FU W28E User Manual

R
FU-W28E  
AIR PURIFIER  
OPERATION MANUAL  
Free standing type  
*Plasmacluster is a trademark of  
Sharp Corporation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ENGLISH  
FEATURES  
CONTENTS  
"Plasmacluster" technology  
.....  
IMPORTANT SAFETY INSTRUCTIONS  
E-2  
Plasmacluster technology uses plas-  
ma discharge to produce and release  
the same positive and negative ions  
as those found in nature ("Plasma-  
cluster ions").  
• WARNING ....................................................  
• CAUTIONS CONCERNING OPERATION ...  
• INSTALLATION GUIDELINES......................  
• FILTER GUIDELINES ..................................  
E-2  
E-3  
E-3  
E-3  
This is a unique air cleaning technol-  
ogy of the SHARP CORPORATION  
for breaking down and eliminating  
such potential allergens as the fecal  
matter or corpses of aerial mites*1,  
viruses *2 and mold and bacteria *3  
suspended in the air, and has been  
substantiated by third-party organiza-  
tions both in Japan and overseas.  
When there is a high density of Plas-  
macluster ions in the air, the smell of  
cigarette smoke trapped in curtains  
or sofas is eliminated in about 80  
minutes, and when clothing is hung in  
a place exposed to the direct air ex-  
pelled from the unit generating Plas-  
macluster ions, the smell of sweat is  
reduced to a virtually imperceptible  
level in one night (about 6 hours).  
...............................................  
PART NAMES  
E-4  
• MAIN UNIT DISPLAY ...................................  
• ILLUSTRATIVE DIAGRAM..........................  
• BACK............................................................  
• INCLUDED...................................................  
E-4  
E-4  
E-5  
E-5  
............................................  
PREPARATION  
E-6  
E-6  
• FILTER INSTALLATION ...............................  
.................................................  
OPERATION  
E-8  
E-8  
• MAIN UNIT OPERATION .............................  
...................  
CARE AND MAINTENANCE  
E-10  
• MAIN UNIT.................................................  
• ODOUR SENSOR......................................  
WASHABLE ACTIVE CARBON FILTER CARE.....  
E-10  
E-10  
E-11  
• FILTER REPLACEMENT  
GUIDELINES..............................................  
E-12  
E-13  
.............................  
TROUBLE SHOOTING  
*1 Graduate School of Advanced Sci-  
ences of Matter, Hiroshima University,  
Japan  
......................................  
SPECIFICATIONS  
E-14  
Measurement of action on the poten-  
tial allergens of aerial mites in (13m²)  
*2 Retroscreen Virology, Ltd., London, UK  
Measurement of ratio of viruses elimi-  
nated from the air in a 1m³ box  
*3 Ishikawa Health Service Association,  
Japan  
....  
INFORMATION ON PROPER DISPOSAL E-15  
Measurement of aerial mold and bac-  
teria with an air sampler (13m²)  
*4 Japan Spinners Inspecting Foundation,  
Japan  
Evaluation of deodorizing effect on  
odor-imbued fragments of cloth  
Thank you for purchasing the SHARP Air Puri-  
fier. Please read this manual carefully for the  
correct usage information. Before using this  
product, be sure to read the section: “Important  
Safety Instructions.”  
After reading this manual, retain it in a conven-  
ient location for future reference.  
E-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
When using electrical appliances, basic safety precautions should be followed, including the  
following:  
- To reduce the risk of electrical shock, fire or injury to persons:  
WARNING  
• Read all instructions before using the unit.  
• Use only a 220-240 volt outlet.  
• Do not use the unit if the power cord or plug is damaged or the connection to the wall outlet  
is loosened.  
Periodically remove dust from the power plug.  
• Do not insert fingers or foreign objects into the intake or air outlet.  
• When removing the power plug, always hold the plug and never pull the cord.  
Electrical shock and/or fire from short circuit may occur as a result.  
• Do not remove the plug when your hands are wet.  
• Do not use this unit near gas appliances or fireplaces.  
• Remove the power plug from the wall outlet before cleaning the unit and when not using the  
unit.  
Electrical shock from bad insulation and/or fire from short circuit may occur as a result.  
• If the power cord is damaged, it must be replaced by the manufacturer, its service agent,  
Sharp authorized Service Centre or similarly qualified person in order to avoid a hazard.  
Do not operate when using aerosol insecticides or in rooms where there is oily residue, incense,  
sparks from lit cigarettes, chemical fumes in the air or in very high humidity condition, such as a  
bathroom.  
Be cautions when cleaning the unit. Strong corrosive cleansers may damage the exterior.  
Only Sharp Authorized Service Centre should service this air purifier. Contact the nearest Service  
Centre for any problems, adjustments, or repairs.  
• This appliance is not intended for use by persons (including children) with reduced physical, sen-  
sory or mental capabilities, or lack of experience and knowledge, unless they have been given su-  
pervision or instruction concerning use of the appliance by a person responsible for their safety.  
Children should be supervised to ensure they do not play with the appliance.  
- Radio or TV Interference  
NOTE  
If this air purifier should cause interference to radio or television reception, try to correct the interfer-  
ence by one or more of the following measures:  
• Reorient or relocate the receiving antenna.  
• Increase the separation between the unit and radio/TV receiver.  
• Connect the equipment into an outlet on a circuit different from that to which the receiver is con-  
nected.  
• Consult the dealer or an experienced radio/TV technician for help.  
E-2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
IMPORTANT SAFETY INSTRUCTIONS  
CAUTIONS CONCERNING OPERATION  
• Do not block the intake and/or air outlet.  
• Do not use the unit near or on hot objects, such as stoves or heaters or where it may come into  
contact with steam.  
• Do not lay the unit down when using.  
• Always hold the handle on the back of the unit when moving it.  
Holding the front panel when carrying may cause it to detach, thus dropping the unit and resulting  
in bodily injury.  
• Do not operate the unit without the filter.  
• Do not wash and reuse HEPA filter .  
It not only does not improve filter performance, it may cause electric shock or malfunction.  
• Clean the exterior with a soft cloth only.  
The unit surface may be damaged or cracked.  
In addition, the sensors may malfunction as a result.  
INSTALLATION GUIDELINES  
• During the operation of the product, please place the unit at least 2 m away from equipment  
which are subject to electrical waves such as televisions, radios or wave clocks.  
• Avoid a location where the sensor is exposed to direct wind.  
The unit may not operate properly.  
• Avoid locations where curtains, etc., come into contact with the intake or air outlet.  
Curtains, etc., may become dirty or a malfunction may occur.  
• Avoid locations where the unit is exposed to condensation, due to drastic temperature  
changes.  
(Use under appropriate conditions between 0 and 35˚C in the room.)  
• Place on a stable surface with sufficient air circulation.  
When placing the unit on a heavily carpeted area, it may cause the unit to vibrate slightly.  
• Do not install when there is generation of lampblack, such as in a kitchen, etc.  
The unit surface may crack or the sensor may malfunction as a result.  
• Leave about 60cm of space from the wall.  
The wall behind the air outlet may become dirty as time passes. When using the unit for extended  
period of time in the same location, use a vinyl sheet, etc., to prevent the wall from becoming dirty.  
In addition, periodically clean the wall.  
FILTER GUIDELINES  
• Follow the instructions in this manual for correct care and maintenance of the filters.  
E-3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PART NAMES  
MAIN UNIT DISPLAY  
POWER ON/OFF Button  
Plasmacluster ON/OFF Button  
Fan Speed Button  
Odour Senser  
Fan Speed Indicator Lights  
Plasmacluster Ion  
ON/OFF  
Indicator Light  
ILLUSTRATIVE DIAGRAM  
Odour Sensor  
Main Unit  
HEPA Filter  
(blue/white)  
Washable Active  
Carbon Filter  
(black)  
Filter Support  
Front Panel  
E-4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Plasmacluster Indicator Light(blue)  
Blue : Plasmacluster ON  
Light off : Plasmacluster OFF  
CLEAN - SIGN Light  
Clean  
Green  
Slightly Impure Very Impure  
The colour changes according to the air condition.  
Orange  
Red  
BACK  
INCLUDED  
• Operation manual  
Handle  
Air Outlet  
Date Label  
Power Cord  
Plug  
(Shape of plug depends on country.)  
E-5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Be sure to remove the power plug from the wall outlet.  
PREPARATION  
FILTER INSTALLATION  
To maintain the quality of the filters, they are installed in the main unit and packed in  
plastic bags. Be sure to remove the filters from the plastic bags before using the unit.  
Front Panel  
Remove the filters  
1
Remove the Front Panel.  
1 Pull the bottom of the Front Panel.  
2 Remove the Filter Support.  
Pinch the two tabs and lift to remove.  
Tabs  
Up side Tabs  
Remove the Active Carbon  
Filter and HEPA Filter.  
3
4
Active Carbon Filter  
HEPA Filter  
Main Unit  
Remove the Active Carbon  
Filter and HEPA Filter from  
the plastic bags.  
Active Carbon Filter  
HEPA Filter  
E-6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install the filters  
2
2
Tab  
Place the HEPA Filter  
HEPA Filter  
1 within the main unit with  
the tabs facing up.  
Do not install the filter backwards  
or the unit will not operate prop-  
erly.  
Place the Active Carbon  
Tabs  
2 Filter on top of the HEPA  
Tabs  
Filter.  
Make sure that the tab of the  
HEPA Filter remains visible.  
Active Carbon Filter  
Insert the bottom side tabs of the Filter Support  
into the associated holes of the main unit.  
Next push the upside tabs into the main unit.  
3
Up side Tabs  
Holes  
Filter Support  
Fix the Front Panel to the  
main unit.  
Bottom side tabs  
4
Fill in the usage start  
5 date on the Date Label.  
Use the date as a guide for the  
Filter Replacement schedule.  
Date Label  
E-7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
MAIN UNIT OPERATION  
Fan Speed Indicator Lights  
Plasmacluster Indicator Light  
Plasmacluster ON/OFF Indicator Light  
Power ON/OFF Button  
• Press to start operation (short beep) and stop operation (long  
beep)  
• Plasmacluster Indicator Light and Fan Speed Indicator Light  
turn on/off.  
• Unless the power cord has been unplugged, the operations  
starts in the previous mode it was operated in.  
Fan Speed Button  
• The operation mode can be switched as below.  
AUTO operation  
MAX operation  
The unit will operate at a  
The fan speed is automatically switched (MEDIUM,  
LOW) depending on the amount of impurities in the air.  
The sensors detect the impurities for efficient air purifi-  
cation.  
fan speed of MAX.  
MEDIUM operation  
The unit will operate at a  
ION SHOWER operation  
fan speed of MEDIUM.  
By continuously discharging strong airflow for 15 min-  
utes the unit effectively removes airborne dust, pol-  
len, mold and allergens from the air as they are drawn  
through the filter system.  
• When the operation finished, the unit will return to the  
AUTO operation.  
SILENT operation  
The unit will operate  
quietly using minimal air  
intake.  
* HIGH fan speed is an intermedi-  
ate speed between MEDIUM  
and MAX.  
POLLEN mode operation  
The unit will operate at HIGH* fan speed for 10 min-  
utes, then will alternate between MEDIUM and  
HIGH* for 20 minutes.  
* LOW fan speed is an intermedi-  
ate speed between SILENT and  
MEDIUM.  
10 minutes: HIGH fan speed  
20 minutes: MEDIUM fan speed  
20 minutes: HIGH fan speed  
E-8  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fan Speed Button  
Plasmacluster ON/OFF Button  
POWER ON/OFF Button  
Clean  
Green  
Slightly Impure Very Impure  
Orange Red  
CLEAN - SIGN Light  
The colour changes according to the air condition.  
ABOUT THE CLEAN-SIGN  
•The condition of the CLEAN-SIGN depends on the room air condition detected by the Odour Sensor  
when the plug is inserted into the wall outlet.  
•It is possible to have a green CLEAN SIGN if there are impurities in the are when the product is first turned on.  
After a while, however, the base impurit rate will be adjusted to detect room air condition correctly.  
Plasmacluster ON/OFF Button  
Press the Plasmacluster ON/OFF Button to turn Plasmacluster  
Ion Mode ON and OFF.  
When Plasmacluster is ON, both the Indicator Light and Plas-  
macluster Indicator Light will turn on.(blue)  
LIGHTS ON/OFF Button  
(Please press the Plasmacluster ON/OFF Button for 3 seconds.)  
Switches the Plasmacluster Indicator Light and CLEAN-SIGN  
Light either ON or OFF.  
ADJUSTMENT OF SENSOR DETECTION SENSITIVITY  
Set to “low” if CLEAN-SIGN Light constantly red to reduce sensitivity, and set to “high”  
if CLEAN-SIGN Light is constantly green to increase sensitivity.  
With the unit OFF, press the Fan Speed Button for 3 seconds  
The Fan Speed Indicator Lights will display the currently set sensor sensitivity level. The  
factory setting is Standard, indicated by the MED light.  
.
1
2
Press the Fan Speed Button to set the  
desired sensor sensitivity  
Fan Speed  
Indicator Light  
Sensor Detection  
sensitivity  
.
Refer to the diagram on the right to select the  
desired sensor sensitivity level.  
High  
Standard  
Low  
Press the Power ON/OFF Button.  
3
Note that if the Power ON/OFF Button is not  
pushed within 8 seconds of adjusting sen-  
sor sensitivity, the setting will be saved auto-  
matically. The sensor sensitivity setting will be  
saved even if the unit is unplugged.  
E-9  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE AND MAINTENANCE  
To maintain optimum performance of this air purifier, please clean the unit including the sen-  
sor and filters periodically.  
When cleaning the unit, be sure to unplug the power cord, and never handle the plug with wet  
hands. Electrical shock and/or bodily injury may occur as a result.  
MAIN UNIT  
Care Cycle 1 month  
To prevent dirt or stains on the main unit, clean as often as necessary. If stains are allowed to  
remain, they may become hard to clean.  
Wipe with a dry, soft cloth  
For stubborn stains or dirt, use a soft cloth dampened with warm water.  
Do not use volatile fluids  
Benzene, paint thinner, polishing powder, etc., may damage the surface.  
Do not use detergents  
Detergent ingredients may damage the unit.  
Keep the unit away from water  
ODOUR SENSOR  
Care Cycle 2 months  
The sensitivity of the sensor will become unstable  
Hole of sensor  
if the odour sensor is dirty or blocked. Remove  
dust from the surface of the sensor opening using  
a vacuum cleaner.  
E-10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WASHABLE ACTIVE CARBON FILTER CARE  
WASHABLE ACTIVE CARBON FILTER CARE  
HAND WASH ONLY!  
DO NOT TUMBLE DRY!  
Care Cycle  
We recommend replacing the active carbon filter every six months.  
Clean the filter as offen as necessary when odour persists.  
Dry filter completely in a well ventilated  
Fill a large container with  
lukewarm water, add a mild  
kitchen detergent and stir.  
Dilute as indi-  
5 area. If possible, dry outdoors.  
1
CAUTION  
cated on the de-  
tergent container.  
• Avoid drying filter outdoors during inclement  
weather (e.g. rain or cold temperatures).  
• Do not allow filter to freeze.  
• If filter is dried indoors, take precautions, such as  
placing towels, etc under the filter to prevent wa-  
ter damage to the floor.  
Allow the filter to soak ap-  
2 proximately 10 minutes .  
Reinstall the Filters.  
6 Reinstall the filters as shown on Page E-6,7.  
Dry filter completely before replacing to pre-  
vent odours.  
Do not operate unit without all filters properly  
installed.  
Rinse thoroughly with  
3 clean water.  
CAUTION  
Filter Support  
If rinsing in a  
container, be  
sure to rinse 3  
to 4 times so  
that the odour is  
rinsed thorough-  
ly from the filter.  
Active Carbon  
Filter  
HEPA Filter  
Main Unit  
Remove excess water.  
The filter will be saturated with wa-  
4
ter after rinsing. To decrease drying  
time, wrap the filter in an old thick  
towel so that excess water can be  
removed.  
CAUTION  
Some carbon  
may adhere to  
the towel, if  
you towel -dry  
the filter, but it  
is harmless.  
E-11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
CARE AND MAINTENANCE  
FILTER REPLACEMENT GUIDELINES  
Depending on the usage environment, air outlet odour may become  
strong after several months.  
If dust or odour cannot be removed easily, replace the filters.  
(Refer to “Please read before operating your new Air Purifier”)  
Guide for filter replacement timing  
• The following filter life and replacement period is based on the condition of smoking 10  
cigarettes per day and the dust collection/deodorization power is reduced by half com-  
pared with that of new filters.  
We recommend to replace the filters more frequently if the product is used in a condition  
significantly severer than normal household use.  
•HEPA Filter  
•Active Carbon Filter  
About 2 years after opening  
About 2 years after opening  
REPLACING THE FILTERS  
See page E-6,7 for directions on  
1
how to install the filters when  
replacing.  
Fill in the usage start date of  
2
Date Label  
the filters on the Date Label.  
Replacement Filters  
Model: FZ-425SEF  
• HEPA Filter : 1 unit  
• Active Carbon Filter: 1 unit  
Please consult your dealer for purchase  
of replacement filters.  
Disposal of Filters  
Please dispose of replaced filters according to the local disposal laws and regulations.  
HEPA Filter materials:  
•Filter: Polypropylene  
•Frame: Polyester  
Active Carbon Filter Materials:  
•Deodorizer: Activated charcoal  
•Nonwoven fabric : Polyester  
E-12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING  
Before calling for repair, please review the list below, since the problem may not be a unit malfunction.  
SYMPTOM  
REMEDY (not a malfunction)  
• Clean or replace the filters if they appear to be heavily soiled.  
(Refer to E-11,E-12)  
Odours and smoke are not  
removed.  
• The air could be impure at the time the unit was plugged in. (Refer  
to E-5) Pull out the plug from the electrical outlet, and insert the  
plug one minute later.  
The CLEAN-SIGN Light lights  
green even when the air is im-  
pure.  
• The sensitivity of the sensor become unstable when the open-  
ing of the odour sensor is dirty or is clogged.  
Clean the dust around the sensor opening using a vacuum  
cleaner. (Refer to E-10)  
The CLEAN-SIGN Light lights  
orange or red even when the  
air is clean.  
• Clicking or ticking sounds may be audible when the unit is gen-  
erating ions.  
A clicking or ticking sound is  
heard from the unit.  
• Check to see if the filters are heavily soiled.  
Replace the filters.  
• Plasmacluster Air Purifiers emit small traces of ozone which  
may produce an odour. These ozone emissions are well below  
safety levels.  
The discharged air has an aro-  
ma or odour.  
• Is the unit installed in a location that is difficult for the sensor to  
detect cigarette smoke?  
• Is the odour sensor opening blocked or clogged?  
(In this case, clean the opening.) (Refer to E-10)  
The unit does not operate when  
cigarette smoke is in the air.  
• Check to see if the Lights OFF Mode is selected. If so, then  
press the Plasmacluster ON/OFF Button for 3 seconds to acti-  
vate the indicator lights.  
The Plasmacluster Indicator  
Light or the CLEAN-SIGN Light  
will not activate.  
(Refer to E-9)  
ERROR DISPLAY  
LAMP INDICATION  
REMEDY  
Fan motor is disconnected or abnormal.  
Operation stops.  
• Pressing the POWER ON/OFF button will reset the error dis-  
play, but if error occurs again, contact the shop where you  
purchased the unit.  
The “SILENT” Fan Speed Indi-  
cator Light blinks.  
E-13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
FU-W28E  
220-240V 50/60Hz  
MED  
Model  
Power supply  
SILENT  
3.9W(3.5W) *1  
30m3/hour  
Fan Speed Adjustment  
MAX  
33W  
168m3/hour  
Fan  
Speed  
Operation  
Rated Power  
12W  
Fan Speed  
90m3/hour  
~21m2 *2  
Recommended Room Size  
~10m2 *3  
High density Plasmacluster ion applicable floor surface  
Cord Length  
Dimensions  
Weight  
2.0m  
410mm(W)x158mm(D)x430mm(H)  
4.3kg  
Numbers in parentheses indicate the power consumption when the Plasmacluster indicator light and the  
CLEAN-SIGN light are off.  
*1  
*2  
The applicable floor surface area is appropriate for operating the unit of maximum fan speed.  
•Applicable floor surface area indicates the space where a certain amount of dust particles can be  
removed in 30 minutes.(JEM1467)  
*3  
Size of a room in which approximately 7000 ions can be measured per cubic centimeter in the  
center of the room (at a height of approximately 1.2 meters from the floor) when the product is  
placed next to a window and run at the MAX operation position.  
In order to operate the electrical circuits while the power plug is inserted in the  
wall outlet, this product consumes about 0.8W of standby power.  
Standby Power  
For energy conservation, unplug the power cord when the unit is not in use.  
E-14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A. Information on Disposal for Users (private households)  
1. In the European Union  
Attention: If you want to dispose of this equipment, please do not use the ordinary dust  
bin!  
Used electrical and electronic equipment must be treated separately and in  
accordance with legislation that requires proper treatment, recovery and recycling of  
used electrical and electronic equipment.  
Following the implementation by member states, private households within the EU  
states may return their used electrical and electronic equipment to designated  
collection facilities free of charge*. In some countries* your local retailer may also  
take back your old product free of charge if you purchase a similar new one.  
*) Please contact your local authority for further details.  
Attention: Your product is  
marked with this symbol. It  
means that used electrical  
and electronic products  
should not be mixed with  
general household waste.  
There is a separate  
collection system for these  
products.  
If your used electrical or electronic equipment has batteries or accumulators, please  
dispose of these separately beforehand according to local requirements.  
By disposing of this product correctly you will help ensure that the waste undergoes  
the necessary treatment, recovery and recycling and thus prevent potential negative  
effects on the environment and human health which could otherwise arise due to  
inappropriate waste handling.  
2. In other Countries outside the EU  
If you wish to discard this product, please contact your local authorities and ask for the  
correct method of disposal.  
For Switzerland: Used electrical or electronic equipment can be returned free of  
charge to the dealer, even if you don’t purchase a new product. Further collection  
facilities are listed on the homepage of www.swico.ch or www.sens.ch.  
B. Information on Disposal for Business Users.  
1. In the European Union  
If the product is used for business purposes and you want to discard it:  
Please contact your SHARP dealer who will inform you about the take-back of the  
product. You might be charged for the costs arising from take-back and recycling.  
Small products (and small amounts) might be taken back by your local collection  
facilities.  
For Spain: Please contact the established collection system or your local authority for  
take-back of your used products.  
2. In other Countries outside the EU  
If you wish to discard of this product, please contact your local authorities and ask for  
the correct method of disposal.  
EN  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Memo  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SHARP CORPORATION  
OSAKA, JAPAN  
Printed in China  
TINS-A302KKRZ  
08L  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Shure Microphone EZG SE Series User Manual
Sierra Wireless Modem 2170042 User Manual
Snapper Tiller 6 0730 User Manual
Soleus Air Dehumidifier SG DEH 70EP 2 User Manual
Sony MP3 Player CFM 10 User Manual
Sony Personal Computer VGC RB33GY User Manual
Sunbeam Mixer SM7200 User Manual
Sylvania MP3 Player SMPK7954 User Manual
Sylvania Portable DVD Player SDVD7024 User Manual
Tapco Musical Instrument SQ2 User Manual