T3 Rack Mount Kit
Installation Instructions
for the Sun Microsystems StorEdge T3 Array
T3-R19-H
Kit Contents
List # Part #
Part Name
Quantity Detail
1
SH03001
Rear Mounting Bracket
2
2
3
4
SH03002
SH03003
SH03004
Right Front Mounting Bracket
Left Front Mounting Bracket
Back Plate
1
1
2
SHP900096-000
04/13/05 Rev 2
Page 1 of 5
Proprietary Information of SharkRack, Inc.
32920 Alvarado Niles Road Ste 250, Union City, CA 94587
Download from Www.Somanuals.com. All Manuals Search And Download.
T3 Rack Mount Kit Installation Instructions
Installation Instructions
Step
Detail
1. Measure the distance from the front rack rail to
the rear rack rail.
Distance = _________
2. Assemble the left front mounting bracket, rear
mounting bracket, and back plate in the order as
shown. Set the front and rear mounting brackets
at the distance measured in step 1.
3. Secure the left front mounting bracket and rear
mounting bracket to the back plate using four
8-32 x 3/8-inch flat head screws.
Note: Do not tighten the back plate screws at this
point.
4. Repeat steps 1 through 3 to assemble the right
front mounting bracket, rear mounting bracket,
and back plate.
5. Install the left front mounting bracket, rear
mounting bracket, and back plate (assembled in
step 2) in the left side of the rack enclosure.
Note: Make sure that the mounting flange on the
front mounting bracket is on the bottom.
• Attach the front mounting bracket to the front
left rack rail using three 10-32 x 1/2-inch pan
head screws. Use the first, third, and fourth
screw holes on the front mounting bracket.
• Attach the rear mounting bracket to the rear
left rack rail using three 10-32 x 1/2-inch pan
head screws.
6. Once the assembly is secure in the rack
enclosure, tighten the back plate screws (the
screws installed in step 3).
7. Repeat steps 5 and 6 to install the right front
mounting bracket, rear mounting bracket, and
back plate in the right side of the rack enclosure.
SHP900096-000
04/13/05 Rev 2
Page 3 of 5
Download from Www.Somanuals.com. All Manuals Search And Download.
T3 Rack Mount Kit Installation Instructions
Step
Detail
8. Remove the feet from the bottom of the
StorEdge T3 array.
9. Install the left mounting chassis on the bottom
left side of the T3 array and secure with two
10-32 x 1/4-inch flat head screws.
10. Install the right mounting chassis on the bottom
right side of the T3 array and secure with two
10-32 x 1/4-inch flat head screws.
11. Install the T3 array in the rack enclosure.
• Approach the rack enclosure with the rear of
the array facing the rack enclosure.
• Make sure that the array is resting on top of
the mounting flange on the left front mounting
bracket.
• Slide the array all the way into the rack
enclosure until it stops.
12. Secure the T3 array in the rack enclosure by
tightening the two thumbscrews on the left and
right chassis mounts.
SHP900096-000
04/13/05 Rev 2
Page 4 of 5
Download from Www.Somanuals.com. All Manuals Search And Download.
T3 Rack Mount Kit Installation Instructions
Warranty
LIMITED WARRANTY AND WARRANTY DISCLAIMER - Seller warrants that the System will be
free from defects in materials and workmanship for a period of one (1) year from date of delivery
to customer premises. Seller’s sole liability and Customer’s sole and exclusive remedy for any
breach of this warranty is, at Seller’s option and expense, to repair or replace any defective
System that is returned to it by Customer. Seller will have no obligation under this section to the
extent any defect in the System is caused by or is attributable to negligence, accident, misuse,
abuse, use of the System than in accordance with Seller’s documentation or user manual,
modifications, alterations or repairs to the System made by a party other than Seller, or actions of
third parties or like events outside Seller’s reasonable control. EXCEPT AS EXPRESSLY SET
FORTH IN THIS SECTION, TO THE EXTENT PERMITTED BY APPLICABLE LAW, SELLER
DISCLAIMS ANY AND ALL OTHER WARRANTIES, WHETHER EXPRESS, IMPLIED, OR
STATUTORY, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF
MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, QUALITY, OR
NONINFRINGEMENT, AND ANY WARRANTIES ARISING FROM COURSE OF DEALING OR
USAGE OF TRADE.
LIMITATIONS OF LIABILITY - IN NO EVENT WILL SELLER BE LIABLE FOR ANY SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, LOST
PROFITS OR REVENUE, LOSS OF USE, LOST BUSINESS OPPORTUNITIES OR LOSS OF
GOODWILL), OR FOR THE COSTS OF PROCURING SUBSTITUTE PRODUCTS, ARISING
OUT OF OR IN CONNECTION WITH THESE TERMS OF SALE OR THE USE OF THE
SYSTEM, WHETHER SUCH LIABILITY ARISES FROM ANY CLAIM BASED UPON
CONTRACT, WARRANTY, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY OR
OTHERWISE, WHETHER OR NOT SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH LOSS OR DAMAGE. IN NO EVENT WILL SELLER’S TOTAL CUMULATIVE LIABILITY,
FROM ALL CAUSES OF ACTION AND ALL THEORIES OF LIABILITY, EXCEED THE TOTAL
AMOUNTS ACTUALLY PAID TO SELLER BY CUSTOMER UNDER THE ORDER THAT GIVES
RISE TO ANY LIABILITY HEREUNDER.
SHP900096-000
04/13/05 Rev 2
Page 5 of 5
Download from Www.Somanuals.com. All Manuals Search And Download.
|