SPX Cooling Technologies Humidifier JT Series User Manual

Recold JT Series CoolingTower  
/
/
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recold JC Series CoolingTower Schematic  
/
/
3
Access Doors  
Near Side  
Sump  
gallons  
note 4  
Dimensions inches  
Far Side  
Model  
A
80  
96  
11534  
13912  
13912  
17214  
17214  
18414  
208  
B
76  
76  
77  
C note 2  
31  
37  
D
84  
H
J
6
6
6
6
6
6
6
8
8
8
10  
10  
10  
K
53  
65  
7634  
92  
92  
115  
115  
115  
13914  
13914  
13912  
16412  
188  
R
6114  
61  
65  
67  
67  
71  
71  
78  
78  
78  
102  
102  
102  
Top  
Bottom  
Top  
1
Bottom  
JT1830  
JT2140  
JT2550 - JT2565  
JT3175 - JT3185  
JT31100  
JT37110 - JT37130  
JT37140  
JT40160 - JT40180  
JT40215 - JT40240  
JT40265  
1
1
1
1
1
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
2
2
2
43  
64  
95  
102  
124  
144  
144  
18014  
18014  
192  
217  
217  
225  
248  
273  
4514  
5512  
5512  
6678  
6678  
9314  
9338  
9338  
10012  
10012  
10012  
5114  
1
1
1
1
8014  
8014  
9212  
9212  
9812  
9812  
9812  
11812  
11812  
11812  
51  
51  
1
1
2
2
163  
163  
248  
248  
374  
454  
454  
748  
880  
1012  
7134  
7134  
8412  
9612  
9612  
80  
1
2
2
2
2
2
2
1 note 1  
1 note 1  
1 note 1  
2 note 1  
2 note 1  
2 note 1  
208  
221  
24512  
268  
JT49290 - JT49310  
JT49340 - JT49360  
JT49390 - JT49415  
104  
128  
Note  
4. Water level at top of overflow stand pipe  
1 An additional bottom access door is installed on inlet  
connection end.  
5 Discharge duct flange is C minus 3" and K minus 3".  
2 Overall width of unit at base rail is C plus 1".  
3 Maximum overall height at blower (fan) section is 118".  
A
C
ELIMINATOR  
ACCESS  
INLET  
K
ACCESS  
DOOR  
OUTLET  
SPRAY HEADER  
CLEANOUT  
B
R
EXTERNAL  
FLOAT BOX  
J
MAKEUP  
7
/8" MOUNTING  
12"  
H
12"  
2"  
HOLE (6)  
DRAIN AND  
OVERFLOW  
2" LIFTING  
HOLE (4)  
D
Model  
JT  
1830 2140 2550 2565 3175 3185 31100 37100 37130 37140 40160 40180 40215 40240 40265 49290 49310 49340 49360 49390 49415  
Nominal Tons†  
Supply FPT  
Drain FPT  
Inlet MPT  
Outlet MPT  
Fan Diamter  
Fan RPM  
26  
36  
47  
57  
73  
83  
92  
113  
1
130  
1
142  
1
164  
114  
3
178  
114  
3
195  
114  
3
212  
114  
3
232  
114  
3
264  
114  
5
280  
114  
5
300  
114  
5
325  
114  
5
340  
114  
5
364  
114  
5
1
1
1
1
3
3
3
2
2  
2  
2  
4  
4  
4  
3
212  
4
3
3
3
3
3
4
3
4
3
4
3
3
3
3
(2) 3 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 4 (2) 5 (2) 5 (2) 5 (2) 6 (2) 6 (2) 6  
4
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
8
8
8
18  
625  
21  
600  
25  
430  
25  
500  
31  
350  
31  
400  
31  
37  
37  
37  
40  
40  
40  
40  
40  
49  
49  
49  
49  
49  
49  
462  
360  
410  
445  
385  
415  
385  
415  
430  
243  
267  
246  
271  
253  
278  
Fan CFM  
Motor hp* (0"=14" SP)  
5880 8060 10800 13300 15700 17100 20200 24000 27300 29700 39100 42500 45100 47200 50300 55500 61000 64500 71000 74200 84500  
7.5 10 10 15 20 20 25 20 25 30 25 30 30 40 40 50  
2
3
3
5
5
Motor Frame  
145T 182T 184T 184T 213T 215T 215T 254T 254T 256T 284T 256T 284T 286T 284T 284T 286T 286T 324T 324T 326T  
853 1142 1597 1616 2504 2528 2557 3906 3943 3988 5133 5194 5579 5675 5709 7886 7916 8486 8624 8978 9028  
Shipping Weight lb  
Operating Weight lb** 1210 1675 2390 2410 3870 3900 3915 5980 6010 6060 8250 8310 9365 9460 9500 14120 14150 15820 16000 17410 17460  
* For static pressure from 14" to 12" ESP, use next size larger motor.  
** At normal operating water level in cold water basin.  
Note: All piping connections are for standard GPM. Consult Recold for other  
† Nominal tons are based upon 95°F HW, 85°F CW, 78°F WB and 3  
GPM/ton. The UPDATE web-based selection software provides JT model  
recommendations based on specific design requirements.  
flow rates.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recold JT Series CoolingTower Accessories  
/
/
4
CAPACITY CONTROLS  
VIBRATION ISOLATORS  
Dual Fan Motors—The dual fan motor package is available  
as a proven energy saving capacity control option. It  
consists of furnishing a high efficiency motor, a 1200 RPM,  
low speed motor, two sets of drives and belts, extended  
fan shaft and motor bases on opposite sides of the blower.  
A UL control-starter panel is available as a completely wired  
package for one point connection.  
Spring type vibration isolator rails may be supplied for field  
installation—some units will require base frame structural  
support.  
ELECTRONIC WATER LEVEL CONTROL  
The electronic water level control package provides a  
constant and accurate means of monitoring water level in  
the unit. For this reason, it is often recommended for those  
installations which require year round operation in low  
ambient conditions.  
Variable Speed Drive—A Variable Speed Drive  
automatically minimize the towers noise level during  
periods of reduced load and/or reduced ambient  
temperature without sacrificing the systems ability to  
maintain a constant cold water temperature. This is a  
relatively inexpensive solution, and can pay for itself quickly  
in reduced energy costs.  
The complete package includes an electric float switch with  
stilling chamber which is factory installed in the pan section  
of the unit. An electric solenoid valve for water make-up  
is shipped loose for remote installation. All wiring must be  
provided in the field by others.  
Electric Damper Controls—An electric damper control  
package is available as an accessory for modulating the  
internal damper system. A proportional solid state actuator  
is factory mounted below the fan scroll and attached to  
the damper shaft by connecting linkage. A sensing bulb  
connected to the actuator by a capillary tube is normally  
mounted in the unit pan water basin for monitoring the  
system. However, when specified, a pressure control may  
be supplied for field mounting to allow direct head pressure  
control. An end switch located inside the motor actuator  
may be adjusted to cycle the fan motor on for pressure rise  
and off when dampers close.  
PAN HEATER  
The use of a remote sump tank located indoors is  
a common form of pan water freeze protection for  
evaporative cooling equipment. However, for those  
installations which will not allow this type of system, freeze  
protection may be provided by electric immersion heaters or  
steam or hot water coils installed in the pan.  
The electric heater package consists of immersion  
heaters installed in the pan to provide efficient even  
heat distribution. Standard heaters are selected to  
provide approximately 40°F pan water at -10°F ambient  
temperature. A low water cutout switch is supplied to  
prevent heater operation when the elements are not  
completely submerged. The heaters are monitored by a  
sump thermostat with remote sensing bulb located in the  
pan water. All heaters and controls are factory installed for  
field wiring by others.  
CASING INSULATION  
In order to further reduce the heat loss from the unit  
coil, factory installed insulation on exterior coil panels  
is available. A protective coat of paint is applied to the  
insulation for protection from the weather elements.  
CONTROL – STARTER PANEL  
NOTE: Pan heater packages are designed to prevent  
pan water freezing during unit shutdown with fans and  
pump idle.  
Contains the fan motor starter, disconnect switch,  
thermostat sensing the cold water temperature to control  
the fan motor and control transformer when required by the  
supply power characteristics. All components are contained  
in a NEMA 12 enclosure with UL label and mounted on the  
unit. Fan motor and controls are factory wired to the panel  
to provide single point connection for users power supply.  
STAINLESS STEEL CONSTRUCTION  
In addition to the standard stainless steel basin, fill supports  
and access doors, 300 stainless steel construction is  
offered as an option for upper casing panels.  
Panels for dual fan-motor arrangement include elapsed  
time meters for both motors to aid in determining energy  
savings. NEMA 3R and 4 enclosures are also available.  
RECOLD PRODUCTS  
550 W MERCURY LANE  
BREA, CALIFORNIA 92821  
UNITED STATES  
704 529 6080  
spxcooling.com  
In the interest of technological progress,  
all products are subject to design and/or  
material change without notice.  
©2008 SPX Cooling Technologies, Inc.  
Printed in USA | RECOLD JT-TECH-07A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Sharp Blu ray Player BD HP25S User Manual
Sharp Projector XG P560W User Manual
Shure Microphone EZG 12 User Manual
SIIG Network Card 04 0835A User Manual
Sony Camcorder RM LVR2V User Manual
Sony Car Stereo System MEX BT2700 User Manual
Sony Microcassette Recorder ICD SX35 User Manual
Sony Projector VPL HS51A User Manual
Sony TV Mount SFM1 User Manual
Sportline Fitness Electronics WV3480IS01SPTRA User Manual