Schneider Electric Welder ATV312 User Guide

ENGLISH  
Quick Start Guide - ATV312  
S1A1094202  
DANGER  
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH  
Read and understand this quick start guide before performing any procedure with this drive.  
The user is responsible for compliance with all international and national electrical code requirements with respect to grounding of all  
equipment.  
Many parts of this drive, including the printed circuit boards, operate at the line voltage. DO NOT TOUCH. Use only electrically insulated tools.  
DO NOT touch unshielded components or terminal strip screw connections with voltage present.  
DO NOT short across terminals PA/+ and PC/- or across the DC bus capacitors.  
Before servicing the drive:  
-
-
-
-
-
-
Disconnect all power, including external control power that may be present.  
Place a "DO NOT TURN ON" label on all power disconnects.  
Lock all power disconnects in the open position.  
WAIT 15 MINUTES to allow the DC bus capacitors to discharge.  
Measure the voltage of the DC bus between the PA/+ and PC/- terminals to ensure that the voltage is less than 42 Vdc.  
If the DC bus capacitors do not discharge completely, contact your local Schneider Electric representative. Do not repair or operate  
the drive  
Install and close all covers before applying power or starting and stopping the drive.  
Failure to follow these instructions will result in death or serious injury.  
Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel. No responsibility is assumed by Schneider  
Electric for any consequences arising out of the use of this product.  
Information below is designed to use single drive connected to single motor with a motor cable length less than 50 meters (164 ft).  
In any other case, consult the ATV312 installation manual (BBV46391) and programming manual (BBV46385) on www.schneider-electric.com.  
1
Check the delivery of the drive  
Remove ATV312 from the packaging and check that it has not been damaged.  
WARNING  
DAMAGED DRIVE EQUIPMENT  
Do not operate or install any drive or drive accessory that appears damaged.  
Failure to follow these instructions can result in death, serious injury, or equipment damage.  
Check that the drive reference printed on the label matches the delivery note and corresponding purchase order.  
Write the drive Model Reference: _____________ ___________and Serial Number: ____________________________  
2
Check the line voltage compatibility  
Check that the line voltage is compatible with the supply range of the drive.  
8B0917121134  
Line voltage _______ Volts  
/
Drive voltage range _______ Volts  
Drive range: ATV312     M2 = 200/240 V single phase / ATV312     M3=200/240 V three-phase  
ATV312     N4 = 380/500 V three-phase / ATV312     S6 = 525/600 V three-phase  
3
Mount the drive vertically  
For a surrounding air temperature up to 50 °C (122 °F)  
(a)  
(a)  
(b)  
(a) 50 mm (2 in.)  
(b) 10 mm (0.4 in.)  
See installation manual (BBV46391) on www.schneider-electric.com for other thermal conditions.  
1/4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
(continued)  
Set motor parameters  
Set tUn parameter to YES.  
Customer  
setting  
Menu  
Code  
Description  
Factory setting  
drC-  
[MOTOR CONTROL]  
[Auto Tunning]:  
tUn  
nO  
Auto-Tunning for UnS, FrS, nCr, nSP, nPr and COS  
DANGER  
DANGER  
HAZARD OF ELECTRIC SHOCK OR ARC FLASH  
UNINTENDED EQUIPMENT OPERATION  
The Nominal Motor Parameters UnS, FrS, nCr, nSP, nPr and  
COS must be correctly configured before starting auto-tuning.  
If one or more of these parameters is modified after auto-tuning has  
been performed, tUn will return to nO and the procedure must be  
repeated.  
During auto-tuning, the motor operates at rated  
current.  
Do not service the motor during auto-tuning.  
Failure to follow these instructions will result in death  
or serious injury.  
Failure to follow these instructions will result in death or serious injury.  
8
Set basic parameters  
Customer  
Factory setting  
Menu  
Code  
Description  
setting  
[Acceleration]:  
Acceleration time (s)  
[Deceleration]:  
Deceleration time (s)  
[Low speed]:  
Motor frequency at minimum reference (Hz)  
[High speed]:  
ACC  
3.0  
3.0  
0.0  
dEC  
LSP  
HSP  
ItH  
rrS  
PS2  
PS4  
SA2  
SEt-  
[SETTINGS]  
50.0  
drive rating  
LI2  
Motor frequency at maximum reference (Hz)  
[Mot. therm. current]:  
Nominal current on motor nameplate (A)  
[Reverse assign.]:  
I-O-  
[INPUTS / OUTPUTS CFG]  
Reverse assignment  
[2 preset speeds]:  
LI3  
Preset speeds  
Fun-> PSS-  
[PRESET SPEEDS]  
[4 preset speeds]:  
Preset speeds  
[Summing ref. 2]  
Analog input  
LI4  
Fun-> SAI-  
[SUMMING INPUTS]  
AI2  
9
Set control choice  
Menu  
CtL-  
[COMMAND]  
I-O-  
[INPUTS / OUTPUTS CFG]  
Code  
Description  
[Ref.1 channel]:  
Reference control  
[2/3 wire control]:  
Command control  
5.1 [REMOTE configuration]  
Al1 (factory setting),  
Al2, Al3  
2C: 2-wire (factory setting)  
3C: 3-wire  
5.2 [LOCAL configuration]  
Customer Setting  
Fr1  
AlU1  
tCC  
LOC  
[REMOTE configuration]  
[LOCAL configuration]  
9.1  
9.2  
(Factory setting)  
MODE  
3s  
Factory settings of parameters:  
Fr1 = AI1  
rdY  
LOC  
tCC = 2C  
Factory settings of parameters:  
Fr1 = AIU1  
tCC = LOC  
rrS = LI2  
35.1  
PS2 = LI3  
PS4 = LI4  
[Output frequency] (Hz)  
10  
Start the motor  
3/4  
S1A10942 - 02/2012  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Menus structure  
MODE  
= ENT  
ESC  
3s  
LOC  
rEN  
2s  
rdY  
rdY  
These 3 parameters are  
only visible at first power up  
of the drive.  
MODE  
ESC  
ENT  
3s  
bFr  
Settings can be changed  
subsequently in menu:  
drC- for bFr  
CtL- for Fr1  
I-O- for tCC.  
[Output frequency] (Hz)  
35.  
Fr1  
tCC  
MODE  
rEF-  
[SPEED REFERENCE]  
[SETTINGS]  
SEt-  
drC-  
[MOTOR CONTROL]  
I-O-  
CtL-  
FUn-  
FLt-  
COM-  
SUP-  
[INPUTS / OUTPUTS CFG]  
[COMMAND]  
[APPLICATION FUNCT.]  
[FAULT MANAGEMENT]  
[COMMUNICATION]  
[MONITORING]  
Parameter selection  
= ENT  
ESC  
ESC  
15.  
SEt-  
ACC  
Refer to the programming manual (BBV46385) for comprehensive menu descriptions.  
ENT  
ESC  
ENT  
A dash appears after menu codes to differentiate them from parameter codes.  
26.  
dEC  
Example:  
ENT  
[SETTINGS] (SEt-), ACC parameter.  
26.  
SFr  
1 flash  
(save)  
4/4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
S1A10942 - 02/2012  

Radio Shack Stereo System 15 221 User Guide
Radio Shack Telephone 43 3909 User Guide
RCA Flat Panel Television 37LA30RQ User Guide
RCA Stereo Receiver RT2350 User Guide
Rover Lawn Mower Domestic Rotary Lawnmower User Guide
Samsung Clothes Dryer DV393ETPARA User Guide
Samsung Tablet GTN8000EAATTT User Guide
Sanus Systems TV Mount VLT14 User Guide
Sanyo Battery Charger NBL414 User Guide
Sanyo Cordless Telephone CLT W20 User Guide