L5AM2/US (VCC-WB4000) GB 2003, 6, 6
INSTRUCTION MANUAL
VCC-WB4000
Network Camera
About this manual
Before installing and using this unit, please read this manual carefully. Be sure to keep it
handy for later reference.
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Information to user
This equipment has been tested and found to
comply with the limits for a Class B digital device,
pursuant to Part 15 of the FCC Rules.
Safety Guard
These limits are designed to provide
reasonable protection against harmful
interference in a residential installation. This
equipment generates, uses, and can radiate
radio frequency energy and, if not installed
and used in accordance with the instructions,
may cause harmful interference to radio
communications.
THIS SYMBOL INDICATES THAT
THERE ARE IMPORTANT
OPERATING AND MAINTENANCE
INSTRUCTIONS IN THE
LITERATURE ACCOMPANYING
THIS UNIT.
WARNING:
However, there is no guarantee that
interference will not occur in a particular
installation. If this equipment does cause
harmful interference to radio or television
reception, which can be determined by
turning the equipment off and on, the user is
encouraged to try to correct the interference
by one or more of the following measures:
TO PREVENT THE RISK OF FIRE OR
ELECTRIC SHOCK , DO NOT EXPOSE THIS
APPLIANCE TO RAIN OR MOISTURE.
– Reorient or relocate the receiving antenna.
For the customers in Canada
This Class B digital apparatus complies with
Canadian ICES-003.
– Increase the separation between the
equipment and receiver.
– Connect the equipment into an outlet on a
circuit different from that to which the
receiver is connected.
Pour la clientèle canadienne
Cet appareil numerique de la Classe B est
conforme à la norme NMB-003 du Canada.
– Consult the dealer or an experienced
radio/TV technician for help.
This device complies with Part 15 of the FCC
Rules. Operation is subject to the following
two conditions: (1) This device may not
cause harmful interference, and (2) this
device must accept any interference
received, including interference that may
cause undesired operation.
This installation should be made by a qualified
service person and should conform to all local
codes.
Changes or modifications not expressly
approved by Sanyo may void the user’s
authority to operate this camera.
– 2 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Precautions
In case of problem
Protect from humidity and dust
Do not use the camera if smoke or a strange
odour comes from the unit, or if it seems not to
function correctly. Disconnect the power cord
immediately, and consult your dealer (or a
Sanyo Authorized Service Centre).
To prevent damages to the camera, do not
install it where there is greasy smoke or steam,
where the dampness may get too high, or where
there is a lot of dust.
Protect from high temperatures
Do not open or modify
Do not install close to stoves, or other heat
generating devices, such as spotlights, etc., or
where it could be subject to direct sunlight, as
that could cause deformation, discoloration or
other damages.
Do not open the cabinet, as it may be dangerous
and cause damage to the unit. For internal
settings and repairs, consult your dealer (or a
Sanyo Authorized Service Centre).
Be careful when installing close to the ceiling, in
a kitchen or boiler room, as the temperature may
raise to high levels.
Install where the temperature range will stay
between –10°C and 50°C. (no condensation)
Do not put objects inside the unit
Make sure that no metal objects or flammable
substance get inside the camera. If used with a
foreign object inside, it could cause a fire,
short-circuits or damages.
If water or a liquid gets inside the camera,
disconnect the power cord immediately, and
consult your dealer (or a Sanyo Authorized
Service Centre). Be careful to protect the
camera from rain, sea water, etc.
Cleaning
Dirt can be removed from the cabinet by
•
wiping it with a soft cloth. To remove stains,
wipe with a soft cloth moistened with a soft
detergent solution and wrung dry, then wipe
dry with dry soft cloth.
Be careful when handling the unit
To prevent damages, do not drop the camera or
subject it to strong shock or vibration.
Do not use benzine, thinner or other
•
chemical product on the cabinet, as that may
cause deformation and paint peeling. Before
using a chemical cloth, make sure to read all
accompanying instructions. Make sure that
no plastic or rubber material comes in contact
with the cabinet for a long period of time, as
that may cause damage or paint peeling.
Install away from electric or magnetic
fields
If installed close to a TV, radio transmitter,
magnet, electric motor, transformer, audio
speakers the magnetic field they generate will
distort the image.
English
– 3 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Features
Accessories
Web Server Function
1 Setup CD-ROM . . . . . . . . . . . . . . . . . . . 1 pc.
2 Lens iris plug (4-pin). . . . . . . . . . . . . . . . 1 pc.
3 Ferrite core. . . . . . . . . . . . . . . . . . . . . . . 2 pc.
This camera is equipped with a web server
function. The camera can be accessed using a
computer’s web browser in order to view the
camera images. In addition, up to a maximum of
16 users can simultaneously access a single
camera on the network.
Operating
Network Connections
This camera is equipped with both an Ethernet
connector and an RS-232C connector, allowing
it to be connected to a variety of different
network environments, such as LANs and the
Internet.
environment
The camera requires the following conditions to
operate.
OS: In this manual, the Microsoft® Windows®
•
Wireless LAN Compatibility
98 operating system, the Microsoft®
Windows® Millennium Edition operating
system, the Microsoft® Windows® 2000
operating system and the Microsoft®
Windows® XP operating system are all
referred to as Windows.
The camera can also be used in a wireless LAN
environment by installing the specified wireless
LAN card.
Adoption of JPEG2000
The images captured by the camera are
Microsoft and Windows are trademarks, or
registered trademarks of Microsoft
Corporation in the United States and/or other
countries.
compressed using the JPEG2000 format before
transmission. In comparison to conventional
JPEG formats, this format produces very little
image deterioration and allows large volumes of
data to be transmitted quickly (maximum 30 fps).
Note: The transmission rate will vary depending
on individual network conditions.
CPU: Intel® Pentium® III 800 MHz or higher
•
or similar with equivalent speed capacity
(Pentium® 4 2 GHz recommended)
Intel and Pentium are trademarks or
registered trademarks of Intel Corporation or
its subsidiaries in the United States and other
countries.
Memory: 128 MB or more (256 MB or more
recommended)
Drive: CD-ROM drive
Network card: 10Base-T / 100Base-TX
Protocols: TCP/IP, PPP, FTP, HTTP
Browser: Microsoft Internet Explorer 5.5
SP2 or later
Computer monitor display size of 1024 x
768 pixels or greater
A network environment that can transmit
data at high speeds is required in order to
transmit data at 30 fps.
Alarm Recording and Playback Functions
•
The built-in motion sensor detects movement,
and the camera can also be connected to an
external alarm sensor (such as a switch) that is
set to detect abnormalities, so that images can
be recorded and played back when an alarm
occurs.
•
•
•
•
Day/Night Function
•
The day/night function allows the camera to
adapt to a variety of different luminance
conditions so that color images are monitored
during daytime, but under conditions of low
illumination such as nighttime, it switches
automatically to black & white.
– 4 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Name and Function of Each Part
4
5
3
PC CARD
RS-232C
MONITOR
OUT
ETHERNET
1
6
7
AC24V
GND
D/N IN COM
PC
POWER
1
2
3
MODEM
ALARM IN OUT
DC12V
CLASS 2 WIRING
2
1 Lens mount cap
3 Flange back locking screws (p. 8)
4 Flange back adjustment dial (p. 8)
5 PC CARD slot
Attach this cap to protect the lens mounting
section. When using the camera, remove the
cap and attach the automatic iris-type lens
(sold separately).
Use this slot to insert a memory card or
wireless LAN card.
2 Camera mounting bracket
Note: Make sure that the camera’s power is
This bracket can be installed to either the top
or bottom of the camera as desired. When
changing the position of the camera
mounting bracket, you should always reuse
the screws that have been removed.
turned off before inserting the card.
6 MONITOR OUT connector
When setting up the camera, use this
connector to connect the camera to the video
connector (VIDEO IN) of a monitor for
adjusting the angle of view and focus.
Note: If using a camera mounting bracket (sold
separately), select a location that is strong
enough to bear the full weight of the
camera and the mounting bracket for long
periods, and install the camera and
mounting bracket securely.
7 POWER indicator
This indicator illuminates when 24 V AC or
12 V DC is being supplied to the power input
terminals of the camera.
English
– 5 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Name and Function of Each Part
I
PC CARD
RS-232C
H
G
MONITOR
ETHERNET
OUT
8
AC24V
GND
D/N IN COM
PC
POWER
1
2
MODEM
ALARM IN OUT
DC12V
CLASS 2 WIRING
J
9
F
8 Link indicator
F Power supply input terminals
(AC24V, DC12V, GND)
This indicator illuminates when the camera is
connected to a network. It flashes while data
transmission is in progress.
The indicator switches off when the camera
is connected to a wireless LAN.
G RS-232C connector
Use this connector to connect the camera to
a modem for transmission of data along
telephone lines, or for connecting the camera
to a computer.
9 Alarm/D/N (Day/Night) terminals
Use the PC/MODEM select switch to change
the camera operation between modem and
computer operation.
D/N IN COM
C
D
B
A
H ETHERNET connector
Use this connector to connect the camera
directly to a computer or to a network. Use a
10Base-T or 100Base-TX (Category 5, UTP)
cable to make the connection.
ALARM IN OUT
A ALARM IN terminal (IN)
I Lens iris output connector
Connect this terminal to an infrared
sensor or similar use in external detection
of intruders.
Connect this connector (4-pin socket) to the
lens iris plug of the automatic iris-type lens
(sold separately).
B D/N IN terminal (D/N IN)
J PC/MODEM select switch
This can only be used when COLOR
mode is set. A device such as an infrared
sensor can be used to automatically
switch between color images and black &
white images.
Use this switch to set the function of the
RS-232C connector when connecting the
camera directly to either a modem or
computer.
Note:
C ALARM OUT terminal (OUT)
Make sure that the camera’s power is turned
off before setting the function of the RS-232C
connector.
•
Connect this terminal to a buzzer or lamp
that is used to warn when an alarm is
detected by means of motion sensor or
alarm input. In addition, when the day/night
function (COLOR mode or TIMER mode) is
being used, an IR lamp or other device can
be made to illuminate when monitoring
switches to black & white images. (Output
rating: 18 V, 25 mA)
Using the RS-232C connector to connect the
•
camera to a computer is only done for
service purposes. You should not use the
PC/MODEM select switch yourself.
D Ground terminal (COM)
– 6 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Attaching the Lens
Use a DC-type automatic iris-type lens (sold separately).
1
Remove the lens mount cap.
3
Connect the lens iris plug to the lens iris
output connector of the camera.
(–) control coil
(+) control coil
(+) drive coil
(–) drive coil
1
2
3
4
2
1
3
2
4
1
3
4
2
Attach the CS mount-type lens.
Note:
(Connecting to the lens iris plug)
Lenses from other manufacturers may have
different plug shapes and specifications. In such
cases, you may need to rewire the lens iris plug.
The “L” part of the lens
should be 5 mm or less in
length. If a lens that does not
conform to this standard is
used, it will not be possible to
attach the lens correctly.
1 Cut off the plug of the lens cable, cut off
approximately 8 mm of the insulation, and
then strip the ends of the cable sheaths
leaving approximately 6 mm of sheath intact.
L
Gently screw the lens into the camera.
The following automatic iris-type lenses can
be used.
VCL-CS8LY (standard, f = 8 mm)
•
2 Solder the ends of the cable wires to the
ends of the pins, and then attach the cover of
the lens iris plug.
VCL-CS4LY (wide angle, f = 4 mm)
•
VCL-CS2LY (extra wide angle, f = 2.8 mm)
•
3
2
For C mount type
In order to allow correct adjustment of the flange
back, attach the C mount adapter ring (option) to
the lens before attaching the lens to the camera.
English
– 7 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Flange Back Adjustment
The flange back is the distance between the lens (sold separately) and the image capturing surface of
the camera. It is adjusted at the time of shipment from the factory to accommodate the types of lenses
that are generally assumed to be in use.
Accordingly, the flange back does not normally need to be adjusted. However, if attaching a zoom lens
and changing from wide angle to telephoto, the images may not be captured in proper focus, and so in
such cases the flange back should always be adjusted by following the procedure given below.
1
2
Connect a coaxial cable between the
camera output connector (MONITOR OUT)
of the camera and the monitor’s video
connector (VIDEO IN).
TV monitor
(sold separately)
PC CARD
RS-232C
MONITOR
OUT
ETHERNET
AC24V
GND
D/N IN COM
PC
POWER
Turn on the camera’s power.
Adjust the flange back while viewing the
camera images on the monitor.
1
2
MODEM
ALARM IN OUT
DC12V
Power supply
connector
3
4
Use a Phillips screwdriver to loosen the
flange back locking screws.
3, 6
Move the zoom lens to the telephoto
setting, and then use the lens focus ring
to adjust the focus.
Flange back
locking screw
5
6
Move the zoom lens to the wide angle
setting, and then use the flange back
adjustment dial to adjust the focus.
4
Move the zoom lens from wide angle to
telephoto (repeating steps 4 and 5) and
check that the images are properly
focused. Then tighten the flange back
locking screws.
Flange back
locking screw
5
– 8 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Connections
Turn off the power for all equipment before making any connections.
Basic Connections
1
2
Connect the camera to a computer.
Connect a cable between the ETHERNET connectors of the camera and the computer.
Use a crossed wire-type Ethernet cable.
Connect the power supply.
After connecting the power supply, install the supplied ferrite core A to the power cord.
If using a commercially-available 24 V AC adapter, always be sure to connect the ground wire
(18AWG or higher) to the ground terminal. (Figure 1)
•
If using a 12 V DC power supply (sold separately: DSA-0151CD-12J), make the connections as
shown in Figure 2.
•
Note:
In order to avoid any problems with the camera and the power supply, take sufficient care to
ensure that the polarities are correct when connecting the power supply.
•
When the accessory ferrite cores are attached, they will increase the load on the cable, so after
doing the installation, adjust the cable accordingly.
•
3
Insert the power cord plug into a wall outlet.
The POWER indicator B will illuminate.
Computer
PC CARD
MONITOR
OUT
ETHERNET
RS-232C
1
3
B
A
AC24V
GND
CO
PC
POWER
1
2
MODEM
ALARM IN OUT
CLASS 2 WIRING
DC12V
Ethernet cable
(crossed wire-type cable)
24 V AC connection
12 V DC connection
AC24V
GND
AC24V
GND
DC12V
DC12V
2
2
Figure 1
Figure 2
English
– 9 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Connections
Connecting to a LAN
Connecting to the Internet
Use an Ethernet cable to connect the
ETHERNET connector of the camera to the
LAN’s Ethernet switching hub.
Use an Ethernet cable to connect the
ETHERNET connector of the camera to a device
such as a router or ADSL modem that is
connected to the Internet.
ꢀ Use a straight-type Ethernet cable.
ꢀ If connecting to a router, use a straight-type
Ethernet cable. If connecting to an ADSL
modem or to some other type of device, refer
to the documentation provided with the
device for details on what type of connection
method should be used.
PC CARD
MONITOR
OUT
ETHERNET
RS-232C
LAN
AC24V
GND
COM
PC
POWER
1
2
MODEM
ALARM IN OUT
DC12V
CLASS
2
WIRING
Ethernet cable
(straight type)
PC CARD
MONITOR
OUT
ETHERNET
RS-232C
Internet
AC24V
GND
Ethernet switching hub
COM
PC
POWER
1
2
MODEM
ALARM IN OUT
DC12V
CLASS
2
WIRING
Ethernet cable
(straight type)
Router or ADSL modem
– 10 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
In order to use the camera as a network camera, you must make the following settings in the order
given.
1
Installation of Plug-in Software to the
Computer (p. 12)
Computer
Insert the contents of the supplied setup
CD-ROM to the computer.
Note: The same setup CD-ROM is
supplied with both the network
camera and the network video
server. You can use either CD-ROM
to carry out the installation.
2
Wired LAN Settings (p. 15)
Connect an Ethernet cable between the
camera and the computer and then make
the required initial settings such as the
computer IP address, user name, password
and language.
When these settings are completed, the
initial camera screen will be displayed. This
section gives descriptions of the various
parts of the initial screen for you to refer to.
3
NETWORK SET Settings (p. 20)
This screen lets you carry out operations
such as setting access levels
(Administrator, Operator or User) and
changing passwords.
English
– 11 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
1 Installation of Plug-in Software to the Computer
Install the plug-in software (on the setup CD-ROM) onto the computer that is to be used. Installing the
plug-in software makes it possible to view live images from network cameras using the computer’s web
browser.
1
Turn on the power for the computer.
After Windows has loaded, continue to the
next step.
6
Click the [Next] button.
2
3
Insert the setup CD-ROM into the CD-ROM
drive of the computer.
Click “Start” and then click “Run”.
7
Read the license agreement, and select “I
accept the terms in the license
agreement” if you agree to the terms of
the license. Then click the [Next] button.
4
5
Type “D:\Setup.exe”.
Type the drive letter for the CD-ROM drive of
the computer in place of “D”.
Click the [OK] button.
After a short wait, the installation window will
appear.
Note: Simply answer the prompts that
appear on the screen in order to
continue installing the software. The
installation program has been set up
beforehand to install the software
correctly.
– 12 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
8
Type in your username and organization
name, and then click the [Next] button.
10
Click the [Finish] button.
This completes the installation of the
plug-in software.
9
Click the [Install] button.
Installation of the software will start and the
window display will change to show the
installation progress.
(Uninstalling the plug-in software)
To uninstall the plug-in software, select
“Add/Remove Programs” from the Windows
Control Panel, and delete “J2KCORE”.
English
– 13 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
Browser Settings
Cookie Settings
Check that the Security settings for Microsoft
Internet Explorer are set as described below.
Select Internet Options from the Tools menu,
click the Security tab and then click the Custom
Level button to display the settings.
The camera uses cookies.
If using Internet Explorer Version 6.0 as the web
browser, select Internet Options from the Tools
menu, click the Privacy tab, move the slide bar
to the “Medium” or lower position and then click
the [OK] button.
Note: If using Internet Explorer Version 5.5 SP2,
click the Security tab.
1
2
Click “Enable” for “Run ActiveX controls
and plug-ins” in the “ActiveX controls and
plug-ins” section.
Click “Enable” for “Active scripting” in
the “Scripting” section and then click the
[OK] button.
– 14 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
2 Wired LAN Settings
Once the plug-in software has been installed, use the computer’s web browser to access the camera.
Note: The network camera handles large volumes of image data that has been compressed into
JPEG2000 format. In order to provide smooth access to the camera, you should close any other
applications that you do not need to have open.
1
Use an Ethernet cable to connect the
camera and the computer.
Refer to “Basic connections” in the
“Connections” section.
4
Type in the username (ID3) and the
password (3333), and then click the [OK]
button.
The language selection window will be
displayed.
2
Click on the Network Connections icon in
the computer’s Control panel, and then
make the Internet protocol settings (IP
address and subnet mask) for the
computer.
Note: The username and password settings in
this screen are initially set to the
Administrator level settings (ID: “ID3”;
password: “3333”) so that all required
settings can be made. There are separate
passwords for each of the three access
levels (Administrator, Operator and User),
and the passwords can be changed.
Refer to “Access Level Settings” for
further details.
IP address setting:
The camera’s IP address is set to
“192.168.0.2”, so type in a spare number
that is 3 or higher for the IP address.
Example: “192.168.0.101”
Subnet mask setting:
Type in “255.255.255.0”.
•
•
Language selection window
3
Start the web browser on the computer,
bar and then press the [Enter] key.
The password entry window will be displayed.
The initial screen will be displayed.
English
– 15 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
Initial Camera Screen
The initial screen is displayed once the network camera and the computer have been set. The initial
screen contains the buttons that are required for making various settings, and it also shows live images
from the network camera that have been compressed into JPEG2000 format.
5
6
7
8
I
9
F
G
H
1
2
J
3
4
1 Image quality mode select buttons
Selects the quality for the live images that are
being transmitted.
FINE:
•
The live images being transmitted are
displayed at high quality. The actual image
display quality will vary depending on the
original quality at the time of transmission.
Available settings:
AUTO: (default setting)
•
The live images being transmitted are
automatically adjusted in accordance with the
computer.
Note: The quality of the images will vary
depending on the capabilities of the
computer. If this is a problem, change the
setting to “FINE”. However, when fine
mode is selected, the image display
speed will be slower.
– 16 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
2 Menu select buttons
3 Network disconnect button
The live image display area and setting area
changes when you click on one of these buttons.
[LIVE VIEW] button
Live images can be monitored.
[VIEW FRAME] button
Sets the live image display area to a fixed
image size (720x480).
•
Click this button to shut down operation of the
network camera. The following message will be
displayed when this button is clicked. To
•
reconnect the camera, click the
button in the title bar.
(Refresh)
[NETWORK] button
Used when making network settings.
•
[WIRELESS LAN] button
Used when making wireless LAN settings.
•
[PPP] button
Used when setting up an Internet connection
using a modem.
Archive software (sold separately) is required
when using these settings.
[CAMERA] button
Used when making settings for the camera
such as camera title, image quality and
day/night mode.
[ALARM] button
Used when making settings for alarm
recording and motion sensors.
•
4 [Get JPEG2000 PLUG-IN] button
If you need to install the JPEG2000 plug-in
software, click this button to point the browser to
a website page for downloading the software.
Select “JPEG2000 Plug-in Software” and then
start the download. You will need an Internet
connection in order to download the software.
•
5 ALARM indicator
Camera title
•
Off: No alarm data, or recording of images is
complete
•
Lit red: Post-alarm recording in progress
Lit orange: Pre-alarm recording in progress
[CLOCK] button
Used when setting the camera’s clock.
[RS-232C] button
Used when setting the communication speed
when the camera is connected directly to the
computer.
•
•
•
•
[LANGUAGE] button
•
Click this button if you would like to change
the language. The language selection screen
will be displayed.
[STATUS] button
Used when checking firmware versions and
information relating to the camera.
•
English
– 17 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
6 ALARM DATA indicator
8 BEEP OFF indicator (p. 34)
Lit red: (alarm recording image playback
If “ALARM SOUND MODE” is set to “USE”, this
display appears at the same time as the buzzer
sounds when an alarm is detected. Click the
indicator to stop the alarm buzzer from sounding.
The alarm buzzer will stop automatically when
alarm recording is complete.
•
is possible)
Internal memory or expanded memory
(installed in the PC card slot) is filled by
alarm recording images.
Lit orange: (alarm recording image
playback is not possible)
•
9 FRAME RATE setting
Alarm recording images are currently being
transferred from internal memory to
expanded memory, alarm recording is in
progress, or and expanded memory error has
occurred.
(default setting: HIGH)
Lit green: (alarm recording image
•
Set the image transmission speed from the
drop-down list box. Images can be transmitted at
maximum speed depending on the network
environment that the camera is connected to.
playback is possible)
Alarm data can still be recorded into the
expanded memory.
For example, if the maximum transmission
speed for the network being connected to is 15
fps, then the images can only be transmitted at a
maximum speed of 15 fps, even if the frame rate
is set to “MID 3” or higher.
Note: Refer to “Alarm Settings” for further
details on alarm recording. (p. 32)
7 REMOTE ALARM indicator (p. 38)
Available settings:
If “ALARM OUT MODE” is set to “REMOTE
CONTROL” (remote alarm operation indicator
display: black), the output status from the alarm
output connector can be set to continuous output
or timed output.
BASIC (5 fps), MID 1 (10), MID 2 (15), MID 3
(20), HIGH (30)
F PICTURE QUALITY setting
(default setting: MID 2)
Black indicator:
No output status when “ALARM OUT TIME”
has been set.
•
Red indicator:
•
Use the drop-down list box to select the image
quality (image compression ratio). If a higher
compression ratio is used (BASIC), the volume
of image data becomes smaller (the amount of
image deterioration becomes greater) and the
transmission speed becomes faster.
Output status when “ALARM OUT TIME” has
been selected. When the set time is
exceeded, the indicator changes to black, but
if you click the indicator once more, the
specified indicator illuminates.
Grey indicator:
No output status when “ALARM OUT TIME”
is set to “REMOTE”.
•
Available settings:
BASIC, MID 1, MID 2, MID 3, HIGH
Note: Alarm recording is carried out at the
picture quality that is specified in the
alarm recording settings, not at the setting
that is made here. (p. 41)
Orange indicator:
•
Output status when “ALARM OUT TIME” is
set to “REMOTE”. The output status can be
turned on and off repeatedly by clicking the
indicator.
– 18 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
G RESOLUTION and EXPANSION settings
H IMAGE MODE setting
(default settings: 640x480, x1)
(default setting: COLOR)
Select the image resolution from the
Select whether live images are to be displayed in
color or black and white from the drop-down list
box.
If you select “GRAY” for black and white images,
the amount of data transmitted will be reduced,
so that the transmission speed can be increased.
•
drop-down list box. The volume of data
transmitted will be larger when a higher
resolution is selected.
Use the drop-down list box to set the
•
enlargement ratio to x2 or x4 (when the
image size is 160x120) or x2 (when the
image size is 320x240). The image will
appear coarser when a greater enlargement
ratio is selected.
Note: This setting is the image mode (color or
black & white) for the browser display. It is
not the same as the DAY/NIGHT setting.
I [SET] button
(Selection screen example)
Click this button to accept the settings that have
been made using the drop-down list boxes.
J Image display area
160x120
320x240
Live images are displayed when the [LIVE
•
VIEW] or [VIEW FRAME] menu select button
is clicked.
When the other menu select buttons are
clicked, the respective setting screens are
displayed.
•
640x480
720x480 (720x240)
Note:
When images that are compressed using
JPEG2000 are played back, the image refresh rate
will vary depending on the performance
•
specifications of the computer being used. In
addition, if other applications besides the web
browser are running, this may also cause the image
refresh rate to become slower or may result in
unstable operation. You should avoid running other
applications at the same time as much as possible.
Set the FRAME RATE, PICTURE QUALITY
•
(COMPRESSION RATIO) and RESOLUTION
settings to levels that will not interfere with the
operation of the network. If the amount of data being
transferred is too large for the network environment,
it may have an adverse effect on other network
operations.
The picture quality and image resolution cannot be
changed when pre-alarm recording has been set.
•
English
– 19 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
3 NETWORK SET Settings
These settings are used in order to connect the camera to the network. After these settings have been
completed, you may also have to make wireless LAN settings or PPP settings. More than one camera
can be connected to the same network, but in order to do this, you will need to make settings for each
camera such as assigning separate IP addresses before connecting the cameras to the network.
1
2
3
Default settings displayed
Reset if necessary
4
5
6
7
ꢀ Click the [NETWORK] menu
5 NETWORK SPEED
This sets the speed of data transmission by the
camera.
select button.
The NETWORK SET screen will be displayed,
and the default settings for each item will be
displayed automatically.
Available settings:
64, 128, 256, 512, 1024 (Kbps), NO LIMIT
(Default setting: No limit for transmission speed)
Once you have completed making the settings,
click the [SET] button.
6 HTTP PORT NUMBER
Note: Check with the network system
administrator or Internet Service Provider
if you need to change the IP address 1,
subnet mask 2 or gateway 3 settings.
(default setting: 80)
This setting is used when more than one camera
is connected to a broadband router and a single
IP address for that router is being used to make
the images being monitored by the camera
publicly available over the Internet. Refer to the
documentation provided with the broadband
router for further details.
Normally the HTTP PORT NUMBER setting
should be left “80” without being changed, even
if more than one camera is connected to the
network.
4 Set the password.
There are three access levels available (User,
Operator and Administrator) and separate
passwords can be set for each level. The factory
default settings are shown in Table 1 (p. 23),
and the range of operations varies as indicated
for each access level.
Note: It is recommended that you change the
passwords whenever possible for security
purposes. (p. 21)
– 20 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
If a user at Administrator level accesses a camera
•
7 MAC ADDRESS display
This shows the Mac address for the camera.
while a user at Operator level is accessing the
camera, the Administrator level user will have
priority. In such cases, the Operator level user will
be disconnected and the message “THE UNIT IS
DISCONNECTED!” will be displayed on their screen.
Note:
Up to a maximum of 16 individual users can access
•
a single camera on the network at the same time.
However, only one user out of this maximum of 16
users can be accessing at Operator or Administrator
level at any one time.
If an Operator or Administrator attempts to access
the camera while another user with the same
access level is accessing the camera, the second
access will have priority. In such cases, the first
access will be disconnected, and the message “THE
AUTHORIZED USER LOGGED IN!” will be
displayed on that user’s computer screen.
•
Depending on the network environment, it may not
•
be possible for 16 users to be connected to a
camera at the same time. Once a user has
accessed a camera, the network may not allow
further accesses, so if this happens, change the
resolution for the transferred data (by reducing it) or
change the compression ratio (by increasing it) to
reduce the volume of data being transferred.
Depending on the network environment, the speed
of data transmission to users may drop if the
number of users accessing the same camera
increases, and operations such as refreshing of
images may become delayed.
•
If a 17th user tries to access a camera, the message
•
“THE UNIT IS BUSY!” will be displayed on their
screen. Depending on the network environment, the
message “THE UNIT IS BUSY!” may be displayed
on a user’s computer screen even when less than
16 users are accessing a camera.
Changing a password
Example: To change the password for the
Administrator level (ID3) to “1234”
Passwords can consist of between 4 and 8
numerals.
ꢀ Delete the current password
(“3333”) in the password column
for ID3, type “1234” as the new
password for ID3, and then click
the [SET] button.
The following window will be displayed.
(When a password has been changed)
Check that the details are correct, and then
close the window.
When the camera and the computer are
connected once more, the network password
entry screen will be displayed, so check the
username and type in the new password
(“1234”) in the password column for ID3.
English
– 21 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
Viewing Live Images Without
Typing In a Username or
Password (ID1 only)
Changing the Access Level (ID2
or ID3)
If live images are monitored without using a
password, the [SET] button will change to
“CHANGE ID”. To change the access level to
“ID2” or “ID3”, follow the procedure below.
Normally you need to type in a password at the
password entry screen in order to display the live
image screen. However, if you make the settings
described below, you can view the live image
screen without having to type in a password. In
this case, you will be logged in at user level “ID1”.
1
Delete the password in the password
column for ID1, and then click the [SET]
button.
1
Click the [CHANGE ID] button at the
top-right of the live image screen.
The password entry screen will be displayed.
Note: The password entry screen can also be
displayed by clicking any one of the menu select
buttons.
The following window will be displayed.
Check that the ID1 password is blank, and
then close the window.
2
Type in the user name and password for
the required user level, and then click the
[OK] button.
(Example: ID3, 3333)
The access level will then change to those for
user level ID3 (Administrator).
2
Turn the camera off and then back on
again.
A single-image live image screen will be
displayed.
Note:
If the ID1 password is blank, a single-image
live image screen will always be displayed.
To return to normal password entry, type in a
password for ID1 (example: 1111).
•
•
– 22 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Network Camera (Wired LAN) Settings
Access Level Settings
When operating the network camera, you need to select an access level to either limit operations to
only the monitoring of live images or to allow menu settings to be changed as well.
The access level setting depends on the “Username” and “Password” that are typed in after the wired
LAN settings have been made. (p. 15)
The default access level is “Administrator” (ID3, 3333) which allows all operations to be carried out.
Change the username and password to the desired access level while referring to the table below.
Table 1
Username/password
Access level
For Administrator access level
All operations and settings can be carried out.
Username: ID3
Password: 3333
For Operator access level
Only the following buttons can be operated.
Username: ID2
Password: 2222
For User access level
Only the following buttons can be operated.
Username: ID1
Password: 1111
The transmission setting menu in the live image screen is
disabled.
In order to make it easier to refer to this Instruction Manual when carrying out the various camera
operations, the usernames (_ID1_, _ID2_ and/or _ID3_) are indicated in the top-right corner of the page.
For example, if _ID3_ appears, then the operation is only available at the Administrator level.
English
– 23 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
CLOCK SET Settings
This lets you set the camera’s internal clock. You can also make settings for summer time.
Click the [CLOCK] menu select button.
The CLOCK SET screen will be displayed. Set the date and time using the
drop-down list boxes, and then click the [SET] button.
Note: To return to the live image screen, click the [LIVE VIEW] button.
1
2
3
4
5
1 DATE and TIME settings
4 DAYLIGHT SAVING MODE
The default time setting is 00:00 on Jan 01 2003.
Set the DATE and TIME. The weekday will be
set automatically.
The daylight saving settings are displayed when
“USE” is selected from the drop-down list box.
Available settings:
2 TIMEZONE
This lets you set your standard time zone. Select
the time zone for the camera’s location.
USE: Daylight saving time is used.
When set to “USE”, you can then set the
times for daylight saving to be applied.
•
NO USE: Daylight saving is not used.
•
3 CLOCK ADJUST setting
This synchronizes the camera’s time with the
computer’s time.
Select the time setting from the drop-down list
5 DAYLIGHT SAVING
When the set date and time is reached, the
camera’s time automatically changes from
standard time to summer time. You need to set
the start time (ON) and end time (OFF) for
summer time.
box, and then click the [SET] button.
UNSET: If the time has not been set when
you log in (default setting), it will be set
automatically.
•
WEEK ... Sets the week and weekday.
LOGIN: The time is set automatically each
time you log in.
•
Available settings:
Week: 1ST, 2ND, 3RD, 4TH, LST
Day: SUN, MON, TUE, WED, THU, FRI, SAT
•
OFF: The time is not set.
•
•
Note: Make sure that the computer’s time is set
MONTH ... Sets the start month and end month
correctly.
for summer time.
TIME ... Sets the hours and minutes.
– 24 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
CAMERA Settings
Click the [CAMERA] menu select button.
This lets you set the camera title and adjust the images and make day/night
settings in accordance with the camera setting-up conditions.
The CAMERA SET screen will be displayed.
Note: If you click the [LIVE VIEW] button, the live image screen will be displayed.
2
3
4
1
5
6
7
8
9
F
G
H
I
1 LIVE IMAGE
4 IRIS Level
This displays the live images from the camera.
You can change the various camera settings
while viewing live images.
If you change one of the adjustment settings and
then click the [SET] button, the images in the
live image screen will be changed to reflect the
new setting. If you click the live image screen,
the initial camera screen will be displayed.
Click the
adjust the iris level.
and
buttons repeatedly to
Setting range: 1 to 100
Note: The larger the setting, the wider is the iris.
5 BRIGHT
This lets you set the image brightness to one of
five settings.
2 CAMERA TITLE
Setting range: 1 to 5 (default setting: 3)
This sets the camera title that is displayed in the
live image screen. The default camera title is
“NET_CAM”.
Note: The larger the setting, the brighter are the
images.
3 IRIS
Select automatic iris or electronic iris.
Available settings:
AI: Automatic iris (default setting)
EI: Electronic iris
•
•
Note: The electronic iris does not have an
electronic shutter setting.
English
– 25 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
CAMERA Settings
6 ELECTRONIC SHUTTER
9 GAMMA
This setting is used when IRIS is set to
automatic iris.
Select a value that is suitable for the monitor
being used.
Setting range: 1/60 (default setting), 1/100,
1/250, 1/500, 1/1000, 1/2000,
1/4000, 1/10000
Setting range: 1, 0.8, 0.6, 0.45 (default setting),
0.3
F APERTURE
7 BLC (backlight compensation)
Set to “HIGH” if you would like the contours of
the objects in the images to be emphasized.
(Available settings: NORMAL, HIGH)
Available settings:
OFF (default setting): Backlight
compensation is not carried out.
•
G CONTRAST
MULTI (multiple point photometry):
Backlight compensation is calculated from
the whole image to obtain correct images.
•
Available settings:
NORMAL: When mainly viewing dark places
HIGH: When mainly viewing bright places
•
•
CENTER (center focus photometry):
•
Backlight compensation is calculated based
on the center of the image to obtain correct
images.
H DAY/NIGHT, AGC gain
Click the [DETAIL] button to change the
DAY/NIGHT and AGC Gain settings. The
"DAY/NIGHT SET" screen will be displayed and
detailed settings can be made in this screen.
(p. 27)
8 WHITE BALANCE
Available settings:
AUTO (automatic white balance)(default
•
I [PRESET] button
setting): The white balance is adjusted
automatically to obtain correct colors even if
the light source changes.
Click this button to return all settings to their
factory defaults. A dialog box will be displayed.
Click the [OK] button to return the values to their
factory defaults.
INDOOR: This setting is for when the
camera is being used indoors under
fluorescent lighting.
•
OUTDOOR: This setting is for when the
camera is being used outdoors under natural
sunlight.
•
MANUAL (manual white balance): This lets
•
you make manual fine adjustments to the
white balance. When “MANUAL” is selected,
you can adjust the red and blue colors. It can
be used when the “AUTO” setting does not
give correct color reproduction.
ꢀ Setting manual white balance
(MANUAL)
Click the
and
buttons repeatedly to
adjust the settings for R (red) and B (blue).
Setting range: 0 to 255
Note: The red or blue component becomes
stronger when the setting is higher.
– 26 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
CAMERA Settings
Setting the camera title
3
Click the [SET] button.
The new camera title will be saved and it will
appear in the camera title display of the live
image screen.
1
2
Move the cursor to the current camera
title (e.g. NET_CAM), and delete the title.
Type in the new camera title (e.g.
SANYO01).
Note: The camera title can be up to eight
characters in length, and may include
alphanumeric characters and the
underscore character only.
DAY/NIGHT Settings
The images being monitored can be switched between color and black & white depending on the
luminance of the objects being monitored.
The DAY/NIGHT settings can be selected from one of four modes (AUTO, COLOR, B/W and TIMER).
Click the [DETAIL] button in the DAY/NIGHT field to display the DAY/NIGHT SET screen.
2
3
1
4
5
6
7
English
– 27 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
CAMERA Settings
1 MODE
This sets the DAY/NIGHT mode.
Item
Operation after selection
Required settings
Monitoring switches automatically between
color and black & white depending on the
luminance of the objects.
2 AGC Gain
4 LEVEL
6 BURST
AUTO (p. 29)
Images are monitored in color regardless
of the luminance of the objects. In addition,
devices such as an infrared sensor can be
used to externally switch between color
and black & white.
2 AGC Gain
3 ALARM OUT
5 POLARITY
6 BURST
COLOR (p. 29)
Images are monitored in black & white
regardless of the luminance of the objects.
2 AGC Gain
B/W (p. 30)
Monitoring can be switched between color
and black & white after the length of time
specified.
2 AGC Gain
3 ALARM OUT
6 BURST
TIMER (p. 30)
7 TIMER
2 AGC Gain
5 POLARITY (Set when using COLOR mode)
If the objects are dark, set the AGC Gain to the
maximum value so that images are made
brighter when they are being monitored. The
AGC Gain can be set separately for each mode.
This sets the input polarity for the D/N IN
terminal at the rear of the camera. When a
device such as an infrared sensor is connected
to the D/N IN terminal, it can be used for forcibly
switch from color to black & white.
Available settings:
Available settings: NC, NO
AUTO: +9dB (default setting), +12dB, +15dB
COLOR: –6dB, 0 (default setting), +6dB,
+9dB, OFF (AGC is not used)
•
•
6 BURST
This sets the color burst for MONITOR OUT
connector image signals. Sometimes distortion
can occur when the mode switches from color to
black & white depending on the connection. If
this happens, change this setting to “ON”.
B/W: –6dB, 0, +6dB (default setting), +9dB,
+12dB, +15dB, OFF (AGC is not used)
•
TIMER: +9dB (default setting), +12dB, +15dB,
OFF (AGC is not used)
•
Note: When the AGC gain is increased,
sensitivity will also be increased for
dark objects and they will appear
bright, but interference will also
increase.
Available settings: OFF, ON
7 TIMER (Set when using TIMER mode)
Set the time for switching from color to black &
white from the drop-down list boxes. Monitoring
will be in color at other times.
3 ALARM OUT (Set when using COLOR and
Available settings:
TIMER mode)
ON: When the set time is reached,
monitoring changes to black & white (Default
setting: 18:00)
OFF: When the set time is reached,
monitoring changes to color (Default setting:
6:00)
When an IR lamp or similar device is connected
to the ALARM OUT terminal at the rear of the
camera, the IR lamp can be made to illuminate
when the mode switches from color to black &
white.
•
•
Available settings: OFF, NC, NO
Note: Settings that overlap a day can also be
4 LEVEL (Set when using AUTO mode)
made.
This sets the luminance for switching
automatically between color and black & white.
Available settings: LOW, MID (default setting),
HIGH (switching at brighter luminances)
– 28 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
CAMERA Settings
ꢀ AUTO Mode Settings
ꢀ COLOR Mode Settings
1
Click the [DETAIL] button in the
DAY/NIGHT field and set MODE to
“AUTO”.
1
Click the [DETAIL] button in the
DAY/NIGHT field and set MODE to
“COLOR”.
1,2
1,2,3
2
3
Set “AGC Gain” to “+12 dB” (example).
2
3
Set “AGC Gain” to “+6 dB” (example).
Set “LEVEL” to “LOW” (example).
Set “ALARM OUT” to “NO” (example).
The switching level for changing between
color and black & white can be set to one of
three levels: LOW, MID and HIGH.
A signal can be output from the ALARM OUT
terminal when monitoring switches to black &
white. (An IR lamp can be connected so that
it illuminates at such times.)
4
Set “BURST” to “OFF” (example).
4
Set “POLARITY” to “NO” (example).
The D/N IN terminal at the rear of the camera
can be used to forcibly switch monitoring
from color to black & white.
3
NO (Normal open): Normally open, so
that when closed, monitoring switches
between color and black & white.
•
4
NC (Normal close): Normally closed, so
that when opened, monitoring switches
between color and black & white.
•
5
Click the [SET] button.
This completes the AUTO mode settings.
Monitoring will switch between color and
black & white according to the set conditions.
4
5
Note: Color/black & white switching settings
are applied when the DAY/NIGHT SET
screen is closed.
5
6
Set “BURST” to “OFF” (example).
Click the [SET] button.
This completes the COLOR mode settings.
Monitoring will switch from color to black &
white according to the set conditions.
English
– 29 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
CAMERA Settings
ꢀ B/W Mode Settings
ꢀ TIMER Mode Settings
Example: To set monitoring to black & white
between 20:00 p.m. and 4.00 a.m.
1
Click the [DETAIL] button in the
DAY/NIGHT field and set MODE to “B/W”.
1
Click the [DETAIL] button in the
DAY/NIGHT field and set MODE to
“TIMER”.
1,2
2
3
Set “AGC Gain” to “+12 dB” (example).
1,2,3
Click the [SET] button.
This completes the B/W mode settings.
Monitoring will switch to black & white
according to the set conditions.
2
3
Set “AGC Gain” to “+12 dB” (example).
Set “ALARM OUT” to “NO” (example).
A signal can be output from the ALARM OUT
terminal when monitoring switches to black &
white. (An IR lamp can be connected so that
it illuminates at such times.)
4
Set “BURST” to “OFF” (example).
4
5
5
6
Change the TIMER ON setting to “20:00”
and the OFF setting to “04:00”.
Click the [SET] button.
This completes the TIMER mode settings.
Monitoring will switch from color to black &
white during the set time period. At other
times, monitoring will be in color.
– 30 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
CAMERA Settings
ꢀ Using an IR lamp to illuminate
during black & white monitoring
in COLOR mode
ꢀ Using an IR lamp to illuminate
during black & white monitoring
in TIMER mode
When using COLOR mode, connect a device
such as an IR lamp to the ALARM OUT terminal
and connect an infrared sensor (for forcibly
switching to black & white monitoring) to the D/N
IN terminal. (Figure 1)
When using TIMER mode, connect a device
such as an IR lamp to the ALARM OUT terminal.
(Figure 2)
The IR lamp can then be made to illuminate
during the black & white monitoring period.
The IR lamp can then be made to illuminate
when monitoring switches to black & white.
Note: Change the ALARM OUT setting for
TIMER mode to “NO” or “NC”. However,
in such cases, the ALARM OUT output
and alarm output settings will be disabled
during alarm recording. (p. 32)
Note: Change the ALARM OUT setting for
COLOR mode to “NO” or “NC”. However,
in such cases, the ALARM OUT output
and alarm output settings will be disabled
during alarm recording. (p. 32)
(Connection example: Figure 2)
D/N IN COM
(Connection example: Figure 1)
D/N IN COM
IR lamp
IR lamp
ALARM IN OUT
ALARM IN OUT
1
2
Change the DAY/NIGHT setting to TIMER
mode.
Set the switching time and switch to black &
white monitoring.
At the same time as the camera images
switch to black & white, an ALARM OUT
(NO/NC) signal will be output and the
connected IR lamp will illuminate.
Note: The IR lamp will illuminate only while
black & white monitoring is being
carried out. Set the polarity so that a
signal is output during black & white
monitoring.
Infrared sensor
1
2
Change the DAY/NIGHT setting to COLOR
mode.
Automatic switching to black & white
monitoring will then be possible using the
infrared sensor that is connected to the D/N
IN terminal.
At the same time as the camera images
switch to black & white, an ALARM OUT
(NO/NC) signal will be output and the
connected IR lamp will illuminate.
Note: The IR lamp will illuminate only while
black & white monitoring is being
carried out. Set the polarity so that a
signal is output during black & white
monitoring.
English
– 31 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
Click the [ALARM] menu select button.
The camera is equipped with two types of alarm function. When an outside
intruder is detected, these alarm functions can be used to record the
images immediately before the alarm occurred (pre-alarm recording) and
the alarm images themselves (post-alarm recording) into the camera’s internal memory or onto a
memory card, and these recorded images can then be played back.
External alarm sensor settings
Motion detector settings
• When a device such as an infrared sensor is
connected to the ALARM IN terminal at the rear of
the camera and this sensor detects an intruder, the
camera images are recorded in the camera's
internal memory.
• While viewing the live images, you can set sensor
marks [ú] in the motion sensor detection area, and
also set the detection sensitivity. When the sensor
detects an intruder, the camera images are
recorded in the camera's internal memory.
• Once “EXTERNAL ALARM” has been set to either
“NO” or “NC”, further detailed settings can then be
made.
• Detailed settings can be made if the “MOTION
DETECTOR” alarm setting is set to “ON”.
1
2
3
COM
4
5
6
7
8
9
F
G
Alarm detection and recording
Alarm checking (Output)
• When an alarm has been detected by either an
external alarm sensor or a motion detector, the
alarm status can be checked visually and/or
audibly.
• If an alarm is detected by either an external alarm
sensor or a motion detector, the ALARM indicator
and the ALARM DATA indicator illuminate
simultaneously.
• For example, if an indicator is connected to the
ALARM IN terminal the indicator can be made to
illuminate when an alarm is being received, or if a
buzzer is connected, it can be made to sound at
this time.
• When images are being recorded in the camera's
internal memory, the ALARM indicator switches off
and the ALARM DATA indicator illuminates red.
Playback of alarm recording images is possible at
this time.
COM
Buzzer etc.
– 32 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
1 ALARM REC USE
6 ALARM OUT
This function stops any motion that occurs
during alarm setting. After the alarm settings
have been made, change this setting to “USE”
so that alarms can be detected in accordance
with the settings.
This is used to make settings for a device such
as a buzzer that is connected to the ALARM
OUT terminal at the rear of the camera when an
alarm is input.
When “NC” (normal close) or “NO” (normal
open) is selected, the ALARM OUT MODE or
ALARM OUT TIME menu is displayed.
2 EXTERNAL ALARM
Select “NC” (normal close) or “NO” (normal
open) to display the external alarm setting menu.
Available settings:
OFF: No alarm is output when an alarm is
•
Available settings:
received.
OFF: No external alarm input is detected.
NC: Normal close (normally closed, but input
is detected when open).
•
NC: Normal close (normally closed, but an
alarm is output when open).
NO: Normal open (normally open, but an
alarm is output when closed).
•
•
•
NO: Normal open (normally open, but input
is detected when closed).
•
7 ALARM OUT MODE
3 MOTION DETECTOR
This operation can be used to manually switch to
output to the ALARM OUT terminal regardless of
whether an alarm is being received or not. When
set to “ON”, the REMOTE ALARM indicator is
displayed in the initial screen. (p. 38)
When set to “ON”, the MOTION DETECTOR
SET screen is displayed. Sensor marks (ú) are
used to set the detection area in this setting
screen.
4 MOTION DETECTOR LEVEL
This sets the sensitivity level for the sensor
marks (ú). See p. 38 for details on the sensitivity
level.
5 ALARM MODE
This selects what combination of external alarm
and motion detector is to be used to provide
alarm input. Make this setting when “EXTERNAL
ALARM” is set to either “NC” or “NO” or
“MOTION DETECTOR” is set to “ON”.
The ALARM OUT terminal settings also need to
be made.
8 ALARM OUT TIME
This sets the alarm duration when the external
alarm or motion detector detects an alarm, or
when the REMOTE ALARM button is pressed
when using the remote function.
The “REMOTE” setting only appears when
“ALARM OUT MODE” is set to “REMOTE
CONTROL”.
Available settings:
AND: An alarm is generated when both the
external alarm and the motion sensor receive
alarm input.
•
Available settings:
2, 5, 10, 15, 20, 30, 60 sec.,
2, 3, 4, 5 min., REMOTE
OR: An alarm is generated when either the
external alarm or the motion sensor receives
alarm input.
•
English
– 33 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
9 ALARM SOUND MODE
1 ALARM DATA SIZE
This setting causes an alarm warning to sound
when an alarm is detected. If set to “USE”,
“BEEP OFF” appears in the initial screen when
an alarm is detected at the same time as the
alarm buzzer sounds. If you click this indicator,
the alarm buzzer will stop.
This sets the size for alarm data that is recorded
into the internal memory. The pre/post selection
ratio for the alarm recording area will vary
depending on the size that is set.
Available settings:
16, 12, 8, 4 MB: All available alarm recording
area ratios can be selected.
•
2 MB: The pre/post ratio of 1/9 cannot be
selected.
•
1 MB: The pre/post ratios of 1/9 and 2/8
cannot be selected.
•
0.5 MB, TWO IMAGES: The pre/post ratio is
fixed at 0/10.
•
F ALARM BUFFERING
Set to “ON” to record alarm recording images
into the camera’s internal memory, and then
click the [DETAIL] button. The ALARM
BUFFERING SET screen will be displayed so
that you can make detailed settings.
Note: “TWO IMAGES” can be selected when
PPP is being used.
2 BUFFERING AREA
This sets the ratio between the pre-alarm and
post-alarm recording areas in the internal
memory.
G RECORD SIZE
If “FULL” is selected, data is recorded
Available settings:
continuously until the selected record size (such
as 16 or 12MB) is reached. Furthermore the
“CC” setting allows data to be recorded in the
internal memory up to the specified size but only
while the external alarm is being detected (while
an external alarm signal is being input).
(PRE/POST) 0/10, 1/9, 2/8, 3/7, 4/6, 5/5
3 BUFFERING RATE
This sets the recording rate (buffering rate) when
data is being recorded into the internal memory.
Available settings:
Available settings:
MAX, 10FPS, 5FPS, 2FPS, 1FPS
FULL, CC (can only be set when MOTION
DETECTOR is set to “OFF”)
4 PRIORITY
This sets the quality for the images recorded in
the internal memory.
ALARM BUFFERING SET Setting
If you click the [DETAIL] button next to “ALARM
BUFFERING”, the ALARM BUFFERING SET
screen will be displayed. This screen is used to
set the way in which the alarm data that is
generated when an alarm is detected is
recorded into the camera’s internal memory. The
recording capacity of the internal memory is set
to a default of approximately 16 MB per alarm
event.
PICTURE QUALITY: Alarm images are
recorded at high image quality.
•
TIME: Images are recorded with speed as
the priority.
•
When this setting is made, the time taken for
recording alarm data is reduced.
1
2
3
4
5
6
– 34 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
5 ALARM RESOLUTION
This sets the image size for data being recorded
into the internal memory.
5
6
Set “ALARM OUT MODE” to “ALARM
OUT”.
Note: When playing back images that have
been recorded at a size of 720x240, the
vertical size will be adjusted so that they
become 720x480 images.
Use the drop-down list box to change the
“ALARM OUT TIME” setting to “60 sec.”
(example).
7
Set “ALARM SOUND MODE” to “USE”.
6 OVERWRITE
Always be sure to insert the expansion memory
card into the card slot before turning on the
power for the camera. If you insert the card after
the power has been turned on, this item will not
be displayed.
7
9
8
If this is set to “ON”, old alarm images are
automatically deleted when the internal memory
becomes full, and the new data is written over as
it is captured.
8
Set “RECORD SIZE” to “CC”.
If “CC” is selected, recording will only be
carried out while an alarm is being input. If
“FULL” is selected, recording will continue
from the point where an alarm starts to be
input until the recording area is full. The
recording area is the capacity that has been
set in “BUFFERING AREA”.
External Alarm Sensor Setting
1
2
Connect a device such as an infrared
sensor to the ALARM IN terminal at the
rear of the camera.
9
Set “ALARM BUFFERING” to “ON”, and
then click the [DETAIL] button.
The ALARM BUFFERING SET screen will be
displayed.
Set “ALARM REC USE” to “NO USE”
(example).
2
3
10
Change any settings that are required
for recording alarm images into the
internal memory, and then click the
[SET] button.
For example, you can set the following.
3
4
Set “EXTERNAL ALARM” to “NO”
(example).
For example, if a door is closed, it will trigger
an alarm.
For details, see “2 EXTERNAL ALARM”.
Set “ALARM OUT” to “NO” (example).
For example, you can cause a buzzer that is
connected to the ALARM OUT terminal to
sound.
The alarm images (16MB) will be recorded
at high quality at a resolution of 720x240.
For details, see “6 ALARM OUT”.
11
Set “ALARM REC USE” to “USE” and
then click the [SET] button.
4
5
6
When an alarm is detected, the alarm will
sound and the ALARM DATA indicator in
the initial screen will be displayed.
English
– 35 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
(Connection method)
5
Set the sensor marks.
These correspond to the live image screen
and the sensing area.
1 Connect an infrared sensor or similar to
the ALARM IN terminal at the rear of the
camera.
1 Move the pointer to the same position
(grid area) as the area of the live image
screen that you would like sensing to
be carried out, and then click the
mouse button.
2 Connect a buzzer or lamp to the ALARM
OUT terminal.
Once the connections are complete,
install the supplied ferrite core (A) to the
power cord.
A sensor mark (ú) will be displayed. Click
in the same place once more to clear the
mark.
2 In the same way, insert sensor marks
PC CARD
in other places as required.
MONITOR
OUT
ETHERNET
RS-232C
AC24V
GND
D/N IN COM
PC
POWER
1
2
MODEM
ALARM IN OUT
A
DC12V
CLASS
2
WIRING
Buzzer or lamp
1
Infrared sensor or similar
MOTION DETECTOR SET Settings
1
2
3
Set “ALARM REC USE” to “NO USE”
(example).
Set “EXTERNAL ALARM” to “OFF”
(example).
Set “MOTION DETECTOR” to “ON”.
The motion detector level and MOTION
DETECTOR SET screen will be displayed.
1
2
3
4
6
7
Click the [SET] button.
Set “ALARM OUT”, “ALARM OUT MODE”,
“ALARM OUT TIME”, “ALARM SOUND
MODE” and “ALARM BUFFERING” in the
same way as for “External Alarm Sensor
Setting”.
4
Use the drop-down list box to change the
“MOTION DETECTOR LEVEL” setting
(example: “2”).
The smaller the value selected, the higher
will be the sensitivity. Refer to “Motion
Detector Level Sensitivity Setting” for
further details. (p. 38)
– 36 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
External Alarm Sensor and Motion Detector Settings
1
2
3
Set “ALARM REC USE” to “NO USE”
(example).
Set “EXTERNAL ALARM” to “NO”
(example).
Set “MOTION DETECTOR” to “ON”.
The motion detector level and MOTION
DETECTOR SET screen will be displayed.
1
2
3
4
Use the drop-down list box to change the
“MOTION DETECTOR LEVEL” setting
(example: “2”).
The smaller the value selected, the higher
will be the sensitivity. Refer to “Motion
Detector Level Sensitivity Setting” for
further details. (p. 38)
5
6
Set the sensor marks.
Refer to “MOTION DETECTOR SET
Settings”.
Set “ALARM MODE” to “OR” (example).
An alarm will then be triggered if either the
motion detector or the external alarm sensor
detects something. Refer to “5 ALARM
MODE” for details. (p. 33)
7
8
Click the [SET] button.
Set “ALARM OUT”, “ALARM OUT MODE”,
“ALARM OUT TIME”, “ALARM SOUND
MODE” and “ALARM BUFFERING” in the
same way as for “External Alarm Sensor
Setting”.
English
– 37 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
Motion Detector Level Sensitivity
Setting
The default setting for the motion detector
sensitivity is “5”. The setting can be selected
from a level ranging from “1” (High) through to
“10” (Low).
Remote Alarm Operations
You can use the “REMOTE ALARM” indicator to
set alarm output to come out from the ALARM
OUT terminal at the rear of the camera for a
specified period or continuously regardless of
the actual alarm detection status.
A Alarm Output for a Specified
Period
1
Set “MOTION DETECTOR LEVEL” to “2”
(example).
Insert sensor marks for the motion detector
settings (grid area).
1
2
Set “ALARM OUT” to “NO” (example).
Set “ALARM OUT MODE” to “REMOTE
CONTROL”.
3
Set “ALARM OUT TIME” to “5 sec.”
2
While looking at the MOTION DETECTOR
SET screen, click the “ALARM CHECK”
indicator.
The “ALARM CHECK” indicator will
illuminate green for approximately 5 seconds.
Detection of moving objects can be carried
out during this time, so you can prepare a
moving object in the area around the sensor
marks and use it to check the sensitivity
setting level.
(example), and then click the [SET] button.
This completes the setting, so return to the
live image screen. The “REMOTE ALARM”
indicator (black) will be displayed in the initial
screen.
1
2
3
(Green)
4
While monitoring the live images, click the
“REMOTE ALARM” indicator.
3
4
When the sensor marks detect an object,
the “ALARM” indicator will illuminate red.
This indicates that the object has been
detected.
The “REMOTE ALARM” indicator will
illuminate red and an alarm will be output for
only the 5-second period that was set with
“ALARM OUT TIME”. If you repeatedly click
the indicator, a new alarm will be output for
another 5-second period each time you click
the indicator.
(Red)
Repeat the above operation to insert
sensor marks in the optimum positions
and to set the sensitivity.
– 38 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
B Continuous Alarm Output
1
2
Set “ALARM OUT” to “NO” (example).
Set “ALARM OUT MODE” to “REMOTE
CONTROL”.
3
Set “ALARM OUT TIME” to “REMOTE”,
and then click the [SET] button.
This completes the setting, so return to the
live image screen. The “REMOTE ALARM”
indicator (gray) will be displayed in the initial
screen.
1
2
3
4
While monitoring the live images, click the
“REMOTE ALARM” indicator.
The “REMOTE ALARM” indicator will
illuminate orange and an alarm will be output
continuously. If you repeatedly click the
indicator, the continuous alarm output will
turn on and off each time you click the
indicator.
English
– 39 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
Alarm Detection and Recording
B Pre-alarm/Post-alarm Recording
A Using Only Post-alarm Recording
When an alarm is detected, recording is
assigned between the pre- and post-alarm
recording areas in the ratio specified. You can
increase or decrease the length of time that
images are recorded before an alarm is detected.
1
2
Set “BUFFERING AREA” to “(PRE/POST)
0/10”.
When an alarm is detected, the ratio will be
set to Pre = 0 (zero)/Post = 10. In other
words, only post-alarm recording will be set.
1
Set “BUFFERING AREA” to “(PRE/POST)
2/8”.
If an alarm is detected in the live image
screen, the indicators will illuminate as
follows and the images will be recorded
into the internal memory.
2
If an alarm is detected in the live image
screen, the indicators will illuminate as
follows and the images will be recorded
into the internal memory.
(1) Alarm not detected (all indicators are
off)
(1) Alarm not detected (all indicators are
off)
(2) An alarm is detected and alarm data is
recorded automatically into the
internal memory
(2) Pre-alarm recording starts
automatically
Images are recorded in the pre-alarm
recording area (PRE 2).
(Red)
(Orange)
(Orange)
(3) Recording of alarm data into the
internal memory is complete
Once this happens, the recorded data can
then be played back.
(3) Alarm detected:
Alarm data is automatically recorded into the
post-alarm recording area (POST 8).
(Red or green)
(Red)
(Orange)
Note: The alarm data that has been recorded
into the internal memory is recorded at the
PRIORITY and ALARM RESOLUTION
that have been set in the ALARM
BUFFERING SET screen. If high quality
and a large image size have been set, it
will take longer for the images to be
refreshed.
(4) Recording of alarm data into the
internal memory is complete
Once this happens, the recorded data can
then be played back.
(Red or green)
Note:
The display screen in (4) shows that the
alarm recording area is full and overwriting is
set to “OFF”.
•
At times other than this, the ALARM indicator
will illuminate orange.
Settings such as the image size cannot be
changed during pre-alarm recording.
•
– 40 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
Example 2: If “PRIORITY” is set to “TIME”
Recording New Alarm Data
The image quality during pre- and post-alarm
recording will be fixed at “MID1”.
If recording new alarm data into the camera’s
internal memory, you should delete the old data
that is recorded in the memory. This will free up
memory space so that the new alarm data can
be recorded. (p. 48)
Note:
If an expansion memory card (CF) is
•
installed, the alarm data will first be recorded
into the camera’s internal memory, and then
it will be automatically transferred to the
memory card. This is useful for times when
you want to record more than one alarm
event.
The alarm data in the internal memory can
•
be saved into a computer as still images.
Furthermore, the data can also be
downloaded as continuous images.
When alarm data is recorded into the camera’s
internal memory, the settings that are fixed
during pre- and post-alarm recording will be
canceled. However, if a memory card is inserted,
the settings will be fixed until the recording area
becomes full.
Fixed Settings During
Pre/Post-Alarm Recording
If the pre-alarm/post-alarm recording area ratio
is set to something from 1/9 to 5/5 so that
pre-alarm recording can be carried out, the
transmission settings (PICTURE QUALITY,
RESOLUTION and IMAGE MODE (COLOR))
are fixed.
Example 1: If “PRIORITY” is set to “PICTURE
QUALITY”
The image quality during pre- and post-alarm
recording will be fixed at “HIGH”.
English
– 41 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Alarm Settings
Note:
Saving to an Expansion Memory
Card
If you would like to save and play back several
sets of alarm data from the camera’s internal
memory, use a CompactFlash memory card with
a capacity of 16MB or greater.
CompactFlash memory cards are only used to
store alarm data that has been recorded into the
internal memory. This means that you cannot
directly record data onto the CompactFlash
memory cards or directly play back the data they
contain.
If there is no free space on the memory card,
•
•
•
the indicator will illuminate red. If this
happens, replace the memory card with
another card or delete the alarm data.
When inserting and removing the memory
card, make sure that F ALARM
BUFFERING is set to “OFF”, and then turn
off the power. (p. 34)
The PC card slot is for 16-bit 5 V cards only.
Do not use 32-bit card bus types of card, as
the terminal sections are different.
New alarms cannot be received while alarm
data is being moved onto the memory card.
The camera is not equipped with a formatting
function. Use the computer to format the
memory card (only FAT formatting is
supported).
•
•
1
Insert a memory card into the PC card slot
at the rear of the camera, while making
sure that the direction of the card is
correct, and then push the knob down in
the direction of the arrow.
This will lock the card in place.
To remove the card, push the knob in the
direction of the arrow to release the card.
2
A
1
2
3
Insert the expansion memory card.
The alarm data in the internal memory will be
automatically moved to the memory card.
The data will be deleted from the recording
areas of the internal memory at this time.
(Orange)
(Orange)
The ALARM DATA indicator (green) will
illuminate.
If alarms are repeatedly detected in this
condition, the alarm data will be automatically
moved to the memory card.
(Green)
– 42 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Viewing Live Images
The initial screen (live image screen) can be accessed by starting up the computer’s web browser and
pointing it to the IP address for the network camera. The live image screen will then be displayed.
Live images will appear in the display area (1) while they are being monitored.
Use the camera setting screen to change setting such as the image title and iris for the images that
are displayed.
•
Settings relating to the transmission of images, such as PICTURE QUALITY and
RESOLUTION, are set using the drop-down list boxes in the transmission setting area (2).
•
The transmission speed will increase or decrease depending on the settings that are made here.
2
1
Note:
If you would like to change the camera settings using the live image screen, click the mouse on the
live image screen to directly display the camera setting screen.
•
To view the live image screen while some other screen is being displayed, click the [LIVE VIEW]
menu select button.
•
English
– 43 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Viewing Live Images
Viewing the View Frame Screen
Click the [VIEW FRAME] menu select button.
Note: Even if the image size has been set to a
smaller size (160x120 or 320x240), the
images will still be displayed at a size of
720x480. In this case, the image
The menu select buttons will disappear. The live
images in the view frame will be displayed at a
screen size of 720x480, regardless of the screen
size that has been set in the live image screen.
resolution will appear coarser.
To return to the live image screen, click the
[BACK] button.
– 44 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Playing Back Alarm Data
Alarm detection data (when an external sensor or motion detector have been set) and alarm image data
is automatically recorded. Moreover, this data is also played back in the live image screen.
Playing Back Alarm Data in the
Camera’s Internal Memory
Descriptions of Alarm Operation
Buttons
1
2
3
4
1
2
Click the ALARM DATA indicator (while it
is green or red).
The ALARM DATA LIST screen will be
displayed, and an alarm image will be
displayed as a still image in the PREVIEW
screen.
5
6
7
1 [TOP] button
Playback returns to the beginning of the alarm
data that is being played back and then waits in
playback standby. You can then click the [PLAY]
button to play back the data.
Click the [PLAY] button.
The BUFFER DATA VIEW screen will be
displayed (the PRE or POST indicator will
illuminate) and playback of the alarm images
will start. When playback is finished, the
[POST] indicator will change to [END].
2 [PLAY] button
Click this button during playback standby or
when playback is paused to start playback.
3 [STOP] button
If you click this button while playback is in
progress, playback will stop.
4 FRAME RATE
You can select the playback speed for alarm
images using the drop-down list box. If you
change the speed while alarm images are in the
process of being played back, playback will start
again at the selected speed from the beginning
of the data.
Available settings: BASIC, MID, HIGH
Note: The actual playback speed will vary
depending on the alarm data volume and
the network status.
5 [DOWNLOAD] button
Use this button to store alarm data on the
computer.
6 PRE/POST/END indicators
When alarm data is played back, this
automatically appears as [PRE] (during
pre-alarm image playback) or [POST] (during
post-alarm image playback). When playback is
finished, it changes to [END]. If there are no
pre-alarm images, playback starts from the
post-alarm images.
3
Click the [LIVE VIEW] menu select button.
The screen will return to the live image
screen.
7 [LIST] button
Click this button to switch to the ALARM DATA
LIST screen.
English
– 45 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Playing Back Alarm Data
Playing Back Expansion Memory
Card Images
Playing Back Alarm Images
Stored in a Computer
Refer to p. 50 for details on saving alarm data
into a computer.
1
Click the ALARM DATA indicator while it
is red or green.
The ALARM DATA LIST screen will be
displayed, and the first image that was
recorded will be displayed in the PREVIEW
screen.
1
2
Using Windows Explorer, click on the
download destination and then
double-click the “Download” folder.
Double-click the “alm_viewer_XXXX.html”
file.
The saved alarm data will be displayed as a
still image.
3
Click the [PLAY] button.
Playback will start. When playback is
finished, the [POST] indicator will change to
[END].
2
1
2
Click on the alarm data to be played back,
and then click the [PLAY] button.
The filename of the selected alarm data will
be displayed in the SELECTED DATA box,
and the message “THE UNIT IS LOADING
ALARM DATA.” will appear briefly. When
loading is complete, the BUFFER DATA
VIEW screen will be displayed (the [PRE] or
[POST] indicator will illuminate) and playback
of the alarm images will start automatically.
When playback is finished, the [END]
indicator will be displayed.
– 46 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Playing Back Alarm Data
Descriptions of Alarm Operation Buttons for Saving Data to a Computer
1
2
3
4
5
6
7
8
9
F
1 RESOLUTION
6 [REVERSE]
Reverses playback.
7 [STOP]
This lets you change the resolution of the
images.
(Selection screen example)
If clicked while playback is in progress,
playback stops.
8 [PLAY]
Starts playback.
9 [NEXT]
Carries out playback one frame at a time.
F [END]
Displays the last image in the data.
160x120
320x240
640x480
720x480 (720x240)
2 FRAME RATE
This sets the transmission speed for images.
Available settings: BASIC, MID 1, MID 2,
MID 3, HIGH
3 IMAGE No.
This shows the image number.
The image number changes depending on
the playback status.
4 [TOP]
Displays the first image in the data and also
displays the first image number.
5 [PREVIOUS]
Reverses playback one frame at a time.
English
– 47 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Playing Back Alarm Data
Alarm Data Deleting
1
2
Click the ALARM DATA indicator while it
is red or green.
The ALARM DATA LIST screen will be
displayed.
3
Click the [OK] button.
The alarm data will be deleted.
Note: When deleting more than one set of alarm
data at the same time, the message “THE
UNIT IS REMOVING ALARM DATA.” will
be displayed briefly, and then the selected
alarm data will be deleted.
Click the check boxes to select the alarm
data to be deleted, and then click the
[DELETE] button.
The alarm data delete confirmation dialog
box will be displayed.
– 48 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Saving Live Images and Alarm Images
Saving Live Images onto a
Computer
The camera images that are being monitored
can be saved as still images in the computer’s
storage area in JPEG2000 format.
Saving Alarm Images onto a
Computer as Still Images
Alarm images can be saved as still images in the
computer’s storage area in JPEG2000 format.
1
Right-click the mouse on the alarm image
to be saved.
The images will be paused and an image
save pop-up menu will be displayed.
1
Right-click the mouse on the image to be
saved.
The images will be paused and an image
save pop-up menu will be displayed.
2
3
Click “Save JPEG2000 File As (S)...”.
The Saving JPEG2000 dialog box will be
displayed.
Type in the file name and then click the
[Save] button.
The image will be saved onto the computer.
2
3
Click “Save JPEG2000 File As (S)...”.
The Saving JPEG2000 dialog box will be
displayed.
Type in the file name and then click the
[Save] button.
The image will be saved onto the computer.
To check the saved file, check that the
JPEG2000 plug-in has been installed, and
then use Internet Explorer to view the image.
Note:
When saving images into a computer, the
images will be saved at the selected
resolution.
•
The extension used for the saved images will
be “.jp2”.
•
To check the saved file, check that the
JPEG2000 plug-in has been installed, and
then use Internet Explorer to view the image.
Note:
When saving images into a computer, the
images will be saved at the selected
resolution.
•
The extension used for the saved images will
be “.jp2”.
•
English
– 49 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Saving Live Images and Alarm Images
Saving All of a Single Alarm Event onto a Computer
1
2
Click the ALARM DATA indicator while it
is red or green.
The ALARM DATA LIST screen will be
displayed, and the first image that was
recorded will be displayed in the PREVIEW
screen.
4
Specify the saving destination and the
filename, and then click the [Save] button.
The download will then start.
Do not close the network camera window.
Click the [PLAY] button and then click the
[DOWNLOAD] button.
A message will be displayed while the alarm
data is being downloaded.
5
6
Use Windows Explorer to open the saving
destination folder.
Double-click the “alm_viewer_XXXX.html”
file.
The download will start. When the download
is finished, a message will be displayed.
When this happens, click the [OK] button.
3
When the File Download pop-up menu is
displayed, click [Save].
The Save As dialog box will be displayed.
When you double-click the saved
“alm_viewer_XXXX.html” file, the playback
screen will be displayed. (p. 47)
– 50 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
WIRELESS LAN SET Settings
Make the wireless LAN settings in the following order.
Computer
1
Camera wired LAN settings (TCP/IP settings)
Make sure that the settings in “Network Camera Settings”
(p. 15) have been carried out.
Camera
Computer
Access point
2
3
Wireless LAN device settings (TCP/IP settings)
Refer to the documentation that is provided with the wireless
LAN device for details. The ESS ID, transmission mode and
WEP (encipherment) settings are necessary in order to
complete the camera’s wireless LAN settings. Take note of the
settings made.
Computer
Camera wireless LAN settings (TCP/IP settings)
Camera
Use the same ESS ID, transmission mode and WEP
(encipherment) settings for the camera’s wireless LAN
•
settings as were made for the wireless LAN device. (p. 52)
Insert the wireless LAN card into the camera (Figure 1)
(1) Insert a commercially-available wireless LAN card into the
camera so that it is facing in the right direction, and then
fold down the knob in the direction of the arrow.
Figure 1
This will lock the card in place.
(2) To remove the card, push the knob in the direction of the
arrow to release the card.
Note:
Consult your local dealer for advice on purchasing a
wireless LAN card.
•
When a wireless LAN card as been inserted into the
network camera, the camera should be used in an ambient
•
temperature that does not exceed 40°C.
Computer
Access point
4
Wireless LAN device settings (TCP/IP settings)
When the settings have been completed, the images from the
camera will be transmitted via the wireless LAN device and
can be viewed on the computer as live images.
Camera
English
– 51 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
WIRELESS LAN SET Settings
Camera Wireless LAN Settings
Make these settings after steps 1 and 2 on page 51 have been completed.
2
✱
3
✱
4
5
1
2
Click the [WIRELESS LAN] menu select
button.
The WIRELESS LAN SET screen will be
displayed.
4
Set the encipherment method.
Because the camera and the wireless LAN
device communicate by means of radio
waves, there is the possibility that wireless
packets could be intercepted and decoded by
outsiders. It is recommended that you
complete the encipherment setting in order to
provide greater security. (p. 53)
Select “USE” from the [WIRELESS LAN
USE] drop-down list box.
If the wireless LAN card has been inserted,
the items marked with ✱ will automatically
show details for the inserted card.
5
6
Make the TCP/IP settings.
Obtain the IP address and other information
from your network systems administrator.
3
Type in the same ESS ID that was set for
the wireless LAN device.
The ESS ID can consist of up to 32
alphanumeric characters.
Click the [SET] button and then turn off
the power.
Now make the settings in step 4 (wireless
LAN device settings).
– 52 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
WIRELESS LAN SET Settings
Description of WIRELESS LAN
SET Screen
Encipherment Settings
If you do not type in the same encryption key
that has been set for the wireless LAN device,
communication will not be possible. Make a note
of the encryption key and type it in.
Example: Encryption key 1: 1234567890000
Encryption key 2: 12345
1
2
Encryption key 3: ABCDE12345678
Encryption key 4: ABCDE
3
4
1
2
If using encryption key 1 (or 3), select
“WEP128” from the drop-down list box.
Click encryption key “1”.
1 CURRENT CHANNEL
The transmission mode (frequency channel) that
was set for the wireless LAN device (access
point) will be displayed here automatically.
3
4
If using encryption key 2 (or 4), select
“WEP40” from the drop-down list box.
2 ESS ID
This is a verification code for transmissions sent
over the wireless LAN from the camera to the
wireless LAN device.
Click encryption key “2”.
Extended Service Set-Identifier
3 WEP ENCIPHERMENT (Default setting:
DISABLE)
This is a security function that encrypts the data
being transmitted so that it cannot be intercepted
by an unauthorized third party.
5
Click the [SET] button.
ESS ID and the encryption key for the
camera and the wireless LAN device will be
verified.
Available settings:
DISABLE: Encipherment is not used.
WEP40 (WEP64): The encryption key uses
40 bit (64 bit) data.
•
Note:
•
If you are not using encipherment, set “WEP
ENCIPHERMENT” to “DISABLE”.
If you do not type in an encryption key, the
encryption key numbers cannot be selected.
•
•
WEP128: The encryption key uses 128 bit
data.
•
128 bit encipherment provides a higher level
of security.
*
WEP: Wired Equivalent Privacy
*
4 ENCRYPTION KEY
Up to four types of encryption key can be set.
Rules for encryption key entry:
WEP40 (WEP64): The encryption key can
consist of up to 5 alphanumeric characters.
•
WEP128: The encryption key can consist of
up to 13 alphanumeric characters.
•
English
– 53 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
PPP (Dial-up) Settings
Two types of PPP settings can be made: Connecting to an “Internet Service Provider” or
“Connecting from a computer”.
PPP Connection to an Internet Service Provider
You can connect the camera to an Internet
5
Install the Network Archiving Software
onto the computer.
Service Provider via a telephone line and then
use the separately-sold Network Archiving
Software to transmit alarm images.
Note: After installing the software, close the
software window.
ꢀ Connecting the camera and
installing the software
6
Make the Camset settings.
Camset only makes the settings that are
required for setting up the camera. Refer to
the documentation for the Network Archiving
Software for further details.
1
2
Camera wired LAN settings (TCP/IP
settings)
Make sure that the settings in “Network
Camera Settings” (p. 15) have been carried
out.
1 Double-click the Camset icon on the
desktop.
When Camset is opened for the first time, no
files have yet been created, so the following
message will be displayed. Click the [OK]
button. “CAMSET MAIN” will then be
displayed.
Connect a serial cable between the
RS-232C terminal at the rear of the camera
and a modem.
PC CARD
Internet
MONITOR
OUT
ETHERNET
RS-232C
AC24V
GND
D/N IN COM
PC
POWER
1
2
MODEM
ALARM IN OUT
DC12V
CLAS
Serial cable
PC
1
2
Modem
MODEM
Set pin 1 to “MODEM”
3
Set pin 1 of the PC/MODEM select switch
at the rear of the camera to the “MODEM”
setting.
Note: After moving the select switch, be sure to
turn the power off and then back on again.
4
Camera PPP settings
Make the settings for transmitting alarm data.
Refer to “DIAL TO PROVIDER Settings” (p.
56) for details.
Note: After making the PPP settings, close the
camera setting screen.
– 54 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
PPP (Dial-up) Settings
2
4
3
5
6
2 Set “CONNECT” to “N”.
5 Click the [SET TO CAMERA] button.
The settings will be loaded into the camera.
6 Click the [SAVE INFO FILE] button.
The settings will be applied to the Network
Archiving Software.
3 Click the [CAMERA SET] and [RECORD
MODE SET] buttons and make the
respective settings.
7 Close the Camset window.
Note:
4 Click the [LOCAL SERVER SET] button.
The camera cannot be accessed using the
•
The LOCAL SERVER SET screen will be
displayed.
computer’s web browser while the camera is
connected to the modem. Use a wired LAN
or wireless LAN to access the camera.
Only alarm image data and alarm data can
be transmitted by means of PPP connections.
LOCAL SERVER USE: Set to “USE”.
LOCAL SERVER IP ADDRESS:
•
•
•
The computer that has the Network
Archiving Software installed becomes a
local server that can be accessed via the
Internet. Type in the global IP address
that has been assigned by the ISP in this
case.
FTP PORT NUMBER: Type in “21”.
FTP PASSIVE: Set to “NO USE”.
CAMERA-ID: Type in a unique
4-character camera name.
•
•
•
English
– 55 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
PPP (Dial-up) Settings
ꢀ DIAL TO PROVIDER Settings
1
2
Click the [PPP] menu select button.
The PPP SET screen will be displayed.
5
IP address and error display
1 AUTO IP ADDRESS: The IP address is
only displayed while the camera is
connected.
Select “USE” from the “DIAL TO
PROVIDER” drop-down list box and then
click the [DETAIL] button.
The PPP SET (TO PROVIDER) screen will
be displayed.
2 ERROR INFO.: Shows the most recent
error information during a PPP connection.
Display details:
Modem timeout or Not connected
•
Line connection error
•
Line disconnected
•
PPP connection error
•
PPP authentication error
•
3
4
Set the following items for connecting to
the access point.
PPP connected and disconnected
normally
•
PROVIDER TEL. NO.:
If you need to dial “0” first, type in the
number as “0-XXX”.
•
LOGIN ID: Type in your user ID for the
provider.
•
6
7
Click the [SET] button.
The PPP SET screen will be displayed.
PASSWORD: Type in your password for
the provider.
•
Select the type of telephone line (CIRCUIT
TYPE).
This sets the type of telephone circuit that the
modem is connecting to.
3
Available settings:
4
TONE: For tone dialing circuits
PULSE: For pulse dialing circuits
•
•
Select the authentication settings
(AUTHENTICATION).
Note: Set to “TONE” if using a terminal adapter.
This sets the authentication protocol to be
used when connecting to the access point.
Set this to the protocol specified by the
8
Type in any AT commands that are
required to control the modem.
Internet Service Provider. It should normally
be set to “AUTO”.
Available settings:
Type in “AT” at the beginning, and then type
in the commands specified by the modem
manufacturer followed by a command to
change flow control to software control.
AUTO (default setting): PAP or CHAP is
chosen automatically as required
•
PAP: Only PAP authentication is used.
CHAP: Only CHAP authentication is used.
•
•
– 56 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
PPP (Dial-up) Settings
PPP Connection from a Computer
9
Make the following settings if required.
You can use the Dial-up networking function of a
computer to connect the computer to the camera
via a telephone line. This method does not
involve an Internet Service Provider.
BAUD RATE: Normally “115200 bps”
DATA SIZE: Normally “8 bits”
PARITY: Normally “NONE”
•
•
•
STOP BIT: Normally “1”
•
Camera
Computer
10
Once you have finished changing the
settings, click the [SET] button.
Modem
ꢀ MODEM CONNECTIONS
The modem should be an RS-232C external
•
modem that is compatible with the command
set devised by Hayes Corporation of the
United States.
Telephone line
Modem
Large volumes of data may be transmitted
•
depending on the alarm settings, so a
high-speed modem using a protocol such as
V.90 should be used.
ꢀ DIAL FROM PC Setting
Note: The maximum receiving speed for the
V.90 protocol is 56 Kbps, but the
transmission speed is 33.6 Kbps.
Because of this, the maximum
1
2
Click the [PPP] menu select button.
The PPP SET screen will be displayed.
transmission speed for alarm data from a
camera or the video server will be
33.6 Kbps, even for modems that use the
V.90 protocol.
Select “USE” from the “DIAL FROM PC”
drop-down list box and then click the
[DETAIL] button.
The PPP SET (FROM PC) screen will be
displayed.
The cameras and video server can only use
•
software (Xon/Xoff) flow control. In may
cases, the modems may be set up to use
hardware (RTS/CTS) flow control. In such
cases, you will need to use AT command
settings to change the modem settings to
software flow control.
Modem commands consist of a single line
•
starting with the letters "AT", followed by the
commands as shown below. Generally you
should issue an "AT&K4" command to switch
to software flow control, but this may vary
depending on the product. Refer to the
specifications for the modem being used for
further details on this.
MODEM: INITIALIZECOMMAND AT&K4
English
– 57 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
PPP (Dial-up) Settings
3
Set the following items.
6
Make the settings in the PPP setting
screen
The settings method for CIRCUIT TYPE, AT
comment input, BAUD RATE, DATA SIZE,
PARITY and STOP BIT are the same as
those given in steps 7 to 9 in “DIAL TO
PROVIDER Settings”.
LOGIN ID: Type in a username of 19
characters or less to use for the dial-up
networking settings on the computer.
•
PASSWORD: Type in a password of 19
characters or less to use for the dial-up
networking settings on the computer.
•
IP ADDRESS: Type in the IP address for
the camera to use during the PPP
connection.
Note:
•
The dial-up networking settings should also
•
•
be made separately for the computer.
Note:
When you have finished using the connection
from the computer, the telephone line will not
be disconnected when the browser is closed,
so you will need to use dial-up networking to
actually terminate the connection.
The same IP address that is used for
•
camera network settings can be typed
in, but in such cases, it will not be
possible to connect using the wired
LAN while a PPP connection is in
progress. To use both connections
simultaneously, type in different
subnets.
Do not set the IP ADDRESS and the
CLIENT IP ADDRESS to the same
address.
•
CLIENT IP ADDRESS: Type in the IP
address that is assigned to the computer
during the PPP connection.
•
3
4
3
4
5
Select the authentication settings
(AUTHENTICATION).
This sets the authentication protocol to be
used when connecting to the access point. It
should normally be set to “AUTO”.
Available settings:
AUTO (default setting): PAP or CHAP is
chosen automatically as required
•
PAP: Only PAP authentication is used.
CHAP: Only CHAP authentication is used.
•
•
Click the [SET] button.
The PPP SET screen will be displayed.
– 58 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
RS-232C Settings (RS-232C SET)
This sets the communication speed for the RS-232C connector of the camera when the camera is
connected to a computer for maintenance and servicing.
Click the [RS-232C] menu select button.
The RS-232C SET screen will be displayed. Select the communication
speed from the drop-down list box, and then click the [SET] button. The
setting will then be saved.
The default setting for the communication speed is 19200 bps.
•
Note: If you click the [LIVE VIEW] button, the display will return to the live image screen.
LANGUAGE Selection
Click the [LANGUAGE] button to change the language.
The language selection screen will then be displayed. Once a language is
selected, the language setting is stored in memory, so the language
selection screen is not displayed the next times you access the camera.
English
– 59 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
STATUS Checking
This displays information about the camera status.
Click the [STATUS] menu select button.
The STATUS screen will be displayed.
Note: If you click the [LIVE VIEW] button, the display will return to the live image screen.
1
2
3
1 FIRMWARE VERSION
This shows the version number for the camera’s
firmware.
2 SUB-MICROCOMPUTER VERSION
This shows the version number for the camera’s
sub-microcomputer.
3 PCMCIA: SOCKET STATUS
This shows the usage status for the PC card slot.
– 60 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Glossary of Terms
Cookie
Hard disk
A system whereby a computer (HTTP server)
that hosts web pages sends information that is
stored by a user’s computer, so that when that
user visits the same web page a second time,
the information that has been automatically
saved is transmitted back to the HTTP server.
For example, it assigns a unique number to the
information from a user and remembers part of
the information that the user has entered, so that
next time the user accesses the web page, the
same information does not need to be entered
all over again.
A storage device for large quantities of data that
is used by equipment such as computers. It
contains a flat disc that is coated with magnetic
particles, and this disc spins around and a
magnetized head is used to read the data stored
on the disc. The data can be read at extremely
fast speeds, giving it excellent data searching
performance.
HTML file
An HTML file is a text file that is written in the
HTML language (a language that is mainly used
to create web pages). The file extensions used
are .htm and .html.
Ethernet
There are a variety of different types of computer
network. Ethernet is a type of network that was
developed by Xerox Corporation.
IP address
A code that allocates “addresses” for each
individual computer and other device on the
Internet or in a network. Devices that
Firewall
A firewall is like a barrier between an outside
network (the Internet) and a local network (LAN).
It is a security measure that is used to prevent
unauthorized access to information by outsiders.
communicate by IP all must have an IP address
assigned to them. Devices that are connected to
the Internet are assigned a unique global IP
address so that no two devices have the same
address. IP addresses consist of a network ID
and a host ID, and the network ID identifies the
address as Class A, B or C.
Firmware
Software that is used to operate a device.
Frame rate
JPEG2000 (Joint Photographic Experts
Group)
An image file compression standard that was
formulated by the International Organization for
Standardization (ISO). It provides higher
compression ratios and higher quality than
conventional JPEG.
This is an indication of how many times an
image is refreshed in a single second when
images are being displayed or moving images
are being played back. If the value (fps) is large,
the rate at which images are refreshed is faster,
but this setting is a theoretical maximum value,
and so if the images are complex, the images
may be refreshed even more slowly. The set
frame rate may not be attained for other reasons
also, such as the image loading time and the
performance of the computer being used.
LAN (Local Area Network)
A computer network that is located within a
relatively small area, such as a single floor of a
company building.
FTP (File Transfer Protocol)
A protocol (communication standard) for
transmitting files via the Internet. This
communication protocol allows files and data to
be transferred via the Web, whereas previously it
was only possible using e-mail.
English
– 61 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Glossary of Terms
MAC address (Media Access Control
address)
SMTP (Simple Mail Transfer Protocol)
A protocol (communication standard) for sending
and receiving electronic mail via the Internet and
Intranets. It controls the flow of mail between
servers and is also used when clients send mail.
A 12-digit hexadecimal identification number that
is assigned to LAN cards and LAN boards in a
computer. Complex device arrangements may
use IP addresses, but whereas IP addresses are
assigned as required by a network system
administrator, MAC addresses are burned into
the LAN card at the time of manufacture.
Ethernet uses the MAC address as the basis for
transmission of data.
Stop bit
A symbol that is added at the end of a byte of
data (8 bits) during data transmission to indicate
the end of that byte.
Subnet mask
Memory
An IP address consists of a network ID and a
host ID. A subnet mask is used to mask part of
an IP address in order to specify whether the IP
address is on a local or a remote network.
A memory device is a semiconductor device that
stores digital data in units of single bits (binary
digits) that consist of either 0s or 1s.
TCP/IP (Transmission Control
Protocol/Internet Protocol)
A network protocol (communication standard)
that was developed by the Network Project that
was funded by the United States Department of
Defense. It can be thought of as the
Modem
A device that converts between analog signals
(from telephone lines) and digital signals (such
as from computers).
Network
A variety of computers and other devices that
are connected together by means of cables
(wired) or via a wireless LAN so that they can
exchange data with each other.
communication technology that makes it
possible to send and receive data over the
Internet. Computers that are connected via the
Internet use this protocol, and it works
regardless of the type of device. Basically IP
controls the sending of data in separate blocks
called “packets”, and TCP receives these
packets, opens them to look at their contents,
and then puts all of them back together into one.
Port number
This is a number that is used to identify
applications on the Internet. For example, SMTP
for e-mail is normally 25 and HTTP (web-related
software) is usually 80.
URL (Uniform Resource Locator)
PPP (Point to Point Protocol)
A method of specifying a resource on the
Internet. An example of an URL that is used to
access a website on the Internet is
A protocol (communication standard) that
determines the process by which two points
(computers) are connected across a network
using telephone lines.
Web browser
Resolution
Software that is used to view web pages. The
two most commonly-used web browsers are
Microsoft Internet Explorer and Netscape
navigator from Netscape Communications.
This indicates the quality of images. The
numbers represent the degree of detail for the
images during printing or displaying, and the
units used are “dpi” (dots per inch).
Router
A device that connects one network to another
network. It looks up IP addresses for network
devices and determines what route should be
used for the information to be transmitted to and
from these devices.
– 62 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Glossary of Terms
Pre-alarm and post-alarm recording
(Alarm input)
Pre-alarm and post-alarm recording involve
recording data according to a selected ratio in
the camera’s internal memory. The default ratio
is pre-alarm = 0 / post-alarm = 10. When an
alarm is detected in this condition, only
post-alarm images are recorded in the camera’s
internal memory.
Post-alarm recording is the recording of alarm
data after an alarm has been detected by an
external sensor or motion detector. When an
alarm is detected, the alarm data is recorded into
the internal memory according to the ratio
selected. If the ratio is 0/10, all of the available
memory space is devoted to post-alarm
recording.
Pre-alarm recording sequentially records alarm
images from immediately before the alarm was
detected according to the ratio selected. When
an alarm is detected, images from before the
alarm that fall within the amount specified by the
ratio selected are recorded in the pre-alarm area
of the internal memory.
Post-alarm recording area (10)
(Internal memory: approx. 16 MB)
(Alarm input)
Pre-alarm
recording
area (3)
Post-alarm recording area (7)
(Internal memory: approx. 16 MB)
For example, if the alarm recording area of the
internal memory is set to a ratio of 3/7, 30% of
the available area is devoted to recording
images from immediately before the alarm is
detected. Actual alarm images are then recorded
in the remaining 70%, and the pre-alarm and
post-alarm recordings are treated as a single
alarm event.
When alarm images are played back, the images
can be viewed continuously starting from the first
images recorded immediately before the alarm
was detected. The alarm recording area ratio is
an important point for consideration when
making settings.
English
– 63 –
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Troubleshooting
If the camera cannot be
connected
If the live image screen does not appear when
you type the camera’s IP address into the
location bar of the web browser, check the
following items.
4
5
Start the web browser and point it to
Is the Ethernet cable connected correctly?
•
If the cable is not connected correctly, the link
indicator at the rear of the camera will not be
illuminated. Check the cable connection.
Check the network settings. (p. 20)
Note: Cross-type and straight-type Ethernet
cables are available. To connect the
camera directly to a computer, you need
to use a cross-type cable.
Is the link indicator flashing?
•
If the link indicator is illuminated steadily, it
means that the cable is connected to the camera
but communication is not possible.
The default network settings for the camera are
as follows.
IP address: 192.168.0.2
Subnet mask: 255.255.255.0
Gateway: 192.168.0.1
Port number: 80
•
•
•
•
6
7
Turn on and off the camera’s power.
If you forget the IP Address
Return the computer’s IP address to its
original setting.
If you forget the camera’s IP address, you can
check it using the following procedure.
Note:
1
2
3
Set pin 1 of the PC/MODEM select switch
at the rear of the camera to the “MODEM”
setting, turn off the camera’s power, wait
three seconds or more and then turn the
power back on.
If the password for the Administrator level ID
has been changed, be careful not to forget
the password.
•
Check that none of the other devices that are
connected to the network have a duplicate IP
address of “192.168.0.2”.
•
Set pin 1 of the PC/MODEM select switch
at the rear of the camera to the “PC”
setting, turn off the camera’s power, wait
three seconds or more and then turn the
power back on.
Set the computer’s IP address to
“192.168.0.✱”.
Enter a spare number that is 3 or greater as
the host address.
– 64 –
English
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Specifications
Lens
: CS mount
Picture element
Effective pixels
Minimum object illumination
White balance
: 1/3 inch 420,000 pixel CCD
: 768 (H) x 494 (V)
: 0.6 lx (F1.2, color mode), 0.03 lx (F1.2, B/W mode)
: AUTO/INDOOR/OUTDOOR/MANUAL manually
selectable
Electronic shutter
Automatic iris
: 1/60 to 1/10000 sec.
: DC drive, 4-pin
ALARM IN terminal
: 1 (Normal open: Non-voltage make contact; Normal
close: Non-voltage break contact)
: 1 (Motion detector and external input AND/OR output
function, open collector: 18 V, 25 mA)
: Day/night external switching input
: 720 x 480, 720 x 240, 640 x 480, 320 x 240,
160 x 120 pixel
ALARM OUT terminal
D/N IN terminal
Resolution
Compression method
: JPEG2000
Picture quality (compression ratio)
: BASIC (Rough), MID 1 (low), MID 2 (medium),
MID 3 (high), HIGH (maximum)
: Max. 30 fps (640 x 480 pixels)
: Composite video output
Image transfer speed
Monitor output
Interfaces
Ethernet connector
RS-232C connector
PC card slot
: 10/100 Base-T (RJ-45)
: D-Sub 9-pin
: PCMCIA Type II (5 V power supply only)
: 16 MB
: TCP/IP, PPP, FTP, HTTP
: Plug-in browser (Internet Explorer compatible)
: 8 hours
•
•
•
Pre-/post-alarm buffer
Protocols
Software
Clock backup
Operating conditions
Temperature
Humidity
Power supply
Power consumption
Weight
: –10 ~ +50°C
: 90% R.H. or less
: AC 24 V/DC 12 V
: 11 W
•
•
: Approx. 480 g
Dimensions
136 mm
126 mm
85 mm
59 mm
12 mm
51 mm
28 mm
Appearance and specifications are subject to change for improvement without notice.
English
– 65 –
Download from Www.Somanuals.com. All Manuals Search And Download.
SANYO INDUSTRIAL VIDEO
COLOR VIDEO CAMERA LIMITED WARRANTY
OBLIGATIONS
In order to obtain warranty service, the product must be delivered to and picked up from an Authorized Sanyo Service Center at
the user’s expense, unless specifically stated otherwise in this warranty. The names and addresses of Authorized Sanyo Service
Centers may be obtained by calling the toll-free number listed below.
For product operation, authorized service center referral, service assistance or problem resolution, call
CUSTOMER INFORMATION 1-800-421-5013
Weekdays 8:30 AM – 5:00 PM Pacific Time
For accessories and/or parts, call
PARTS ORDER INFORMATION 1-800-726-9662
Weekdays 8:30 AM – 5:00 PM Pacific Time
THIS WARRANTY IS VALID ONLY ON SANYO PRODUCTS PURCHASED OR RENTED IN THE UNITED STATES OF AMERICA,
EXCLUDING ALL U.S. TERRITORIES AND PROTECTORATES. THIS WARRANTY APPLIES ONLY TO THE ORIGINAL RETAIL
PURCHASER OR END-USER. THE ORIGINAL DATED BILL OF SALE, SALES SLIP OR RENTAL AGREEMENT MUST BE
SUBMITTED TO THE AUTHORIZED SANYO SERVICE CENTER AT THE TIME WARRANTY SERVICE IS REQUESTED.
Subject to the OBLIGATIONS above and EXCLUSIONS below, SANYO Fisher Company warrants this SANYO product against
defects in materials and workmanship for the periods specified below. SFC will repair or replace (at its option) the product and
any of its parts which fail to conform to this warranty. The warranty period commences on the date the product was first
purchased or rented at retail.
LABOR
3 YEARS
PARTS
3 YEARS
IMAGE DEVICE
3 YEARS
EXCLUSIONS
This warranty does not cover (A) the adjustment of customer-operated controls as explained in the appropriate model’s
instruction manual, or (B) the repair of any product whose serial number has been altered, defaced or removed.
This warranty shall not apply to the cabinet or cosmetic parts, batteries or routine maintenance.
This warranty does not apply to uncrating, setup, installation, removal of the product for repair or reinstallation of the product
after repair.
This warranty does not apply to repairs or replacements necessitated by any cause beyond the control of SFC including, but not
limited to, any malfunction, defect or failure caused by or resulting from the use of any products operated outside of the
operating temperature ranges stated in our product specification, (i.e., between 41 and 104 degrees Farenheit or between 5
and 40 degrees Celsius), unauthorized service or parts, improper maintenance, operation contrary to furnished instructions,
shipping or transit accidents, modification or repair by the user, abuse, misuse, neglect, accident, incorrect power line voltage,
fire, flood or other Acts of God, or normal wear and tear.
SFC does not guarantee that recorded pictures or information will be maintained on any product sent in for repair or
replacement.
The foregoing is in lieu of all other expressed warranties and SFC does not assume or authorize any party to assume for it any
other obligation or liability.
SFC DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED, WITH REGARD TO THIS PRODUCT (INCLUDING THE
WARRANTIES OF MERCHANTABILITY AND FITNESS). IN NO EVENT SHALL SFC BE LIABLE FOR ANY SPECIAL,
INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE OWNERSHIP OR USE OF THIS PRODUCT OR FOR ANY
DELAY IN THE PERFORMANCE OF ITS OBLIGATIONS UNDER THIS WARRANTY DUE TO CAUSES BEYOND ITS CONTROL.
SFC’S LIABILITY FOR ANY AND ALL LOSSES AND DAMAGES RESULTING FROM ANY CAUSE WHATSOEVER, ARISING
OUT OF OR IN CONNECTION WITH THE SALE, USE OR OWNERSHIP OF THIS PRODUCT INCLUDING WARRANTOR’S
NEGLIGENCE, ALLEGED DAMAGED OR DEFECTIIVE GOODS, WHETHER SUCH DEFECTS ARE DISCOVERABLE OR
LATENT, SHALL IN NO EVENT EXCEED THE PURCHASE PRICE OF THE PRODUCT.
ATTENTION
For your protection in the event of theft or loss of this product, please fill in the information below for you own
personal records.
Model No. _______________________________________ Serial No.
(Located on back or bottom side of unit.) _____________
Date of Purchase _________________________________ Purchase Price ___________________________________
Where Purchased ___________________________________________________________________________________
Download from Www.Somanuals.com. All Manuals Search And Download.
L5AM2/US (VCC-WB4000) GB 2003, 6, 6
Printed on recycled paper
SANYO Electric Co., Ltd.
1AC6P1P2677--
L5AM2/US (0603KP-CZ)
Printed in Japan
Download from Www.Somanuals.com. All Manuals Search And Download.
|