Sanyo Network Card POA LN02 User Guide

POA-LN02  
LD-Net Organizer  
Network Capture 3  
Network Viewer 3  
Network Communication  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Compliance and Caution  
CautioN oN use iN Network  
- When you receive an alert e-mail from the monitor, you must check the monitor  
immediately. Fire or accident may result if the monitor is used in an abnormal condition.  
- When you install the monitor at remote location and use it through the network, you  
must perform the safety inspections periodically. In this case you must pay attention to  
the change of environment in which you installed the monitor. It may cause fire or an  
accident depending on the change of environment.  
CautioN  
SANYO Electric Co., Ltd. assumes no responsibility for the loss or damage of data or  
damage of the computer caused by using this product.  
The CE Mark is a Directive conformity mark of the European Community (EC).  
NOTES ON Lithium Battery (CALIFORNIA USA ONLY)  
This product uses a Lithium Battery which contains Perchlorate Material - special han-  
dling may apply. See www.dtsc.ca.gov/hazardouswaste/perchlorate  
Notas acerca de pilas de litio (SOLO PARA CALIFORNIA, EE.UU.)  
Este producto usa una pila de litio que contiene el material perclorato – puede ser nece-  
sario una manipulación especial.  
Consulte la página www.dtsc.ca.gov/hazardouswaste/perchlorate  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Contents  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1  
1
Preparation  
Describes features and operating environment of this product.  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 1 Preparation  
Features  
real time Capture function ( p.68)  
To display the screen image of  
PC1  
PC2  
PC4  
the computer by the monitor  
through the network in real  
time.  
Capture  
PC3  
PC6  
PC5  
Network Communication function ( p.71)  
To communicate by sharing the  
captured image of a computer  
with multiple computers and  
a monitor. User can draw the  
text and figure on the captured  
image by using a drawing tool.  
MONITOR 1  
Capture  
PC6  
PC1  
PC2  
PC5  
Capture a screen  
image of PC5 and  
make marking with a  
tool.  
Network Viewer function ( p.81)  
To acquire the JPEG image data  
from the file servers placed in  
the network and display them  
by the monitor.  
MONITOR 2  
MONITOR 1  
PC1  
PC2  
JPEG  
PC3  
PC4  
PC6  
PC5  
Prog.  
JPEG  
FTP file server  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Features  
web Management function ( p.45)  
With this function, you can  
MONITOR 2  
MONITOR 1  
check monitor functions such  
PC1  
PC2  
as power status, input mode,  
signal condition, etc. through  
the network by using the web  
browser installed on your com-  
puter.  
PC3  
PC4  
PC6  
PC5  
Turn ON  
MONITOR 2  
e-mail alert function ( p.38)  
The monitor (Network Unit)  
sends messages to the regis-  
MONITOR 2  
MONITOR 1  
PC1  
PC2  
tered e-mail addresses when a  
internal temperature abnormal-  
ity or power failure occurs with  
the monitor.  
PC3  
PC4  
PC6  
PC5  
You’ve got  
Mail.  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 Preparation  
sNMP agent function ( p.42)  
MONITOR 1  
MONITOR 2  
MONITOR 3  
MONITOR 4  
To send the information of the  
monitor to the SNMP manager.  
Enables you to manage the  
monitor condition with the sup-  
plied SNMP manager software.  
Trap  
PC6  
PC5  
You received  
a Trap.  
Trap  
SNMP Manager  
Multi-control function ( p.59)  
A single computer can con-  
MONITOR 1  
MONITOR 2  
MONITOR 3  
MONITOR 4  
trol and set up the multiple  
monitors at the same time.  
PC6  
PC5  
PC4  
Select Input2 for  
MONITOR 1 to  
MONITOR4.  
automatic on/off using Clock function ( p.55)  
Automatically turn on or off the  
monitors at specified date/day  
and time by using the clock func-  
tion.  
I am ready to turn ON,  
and select Input 3 (Video)  
Now it’s 11:30  
sNMP Manager function (refer to the separated booklet)  
A function to manage the  
ITOR 1  
MONITOR 2  
MONITOR 3  
MONITOR 4  
condition of monitors in the  
network by using the SNMP  
protocol. The managing com-  
puter needs to provide an  
SNMP managing software. Refer  
to the owner's manual of the  
"PJ Network Manager" supplied  
separately for further details.  
Trap  
PC6  
PC5  
PC4  
You received  
a Trap.  
Trap  
SNMP Manager  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operating Environment  
operating environment of LD-Net organizer  
To perform the managing and setting of the monitor by using this product, the environ-  
ment described below is required.  
Standard mode  
Windows 98, Windows Me, Windows NT4.0SP6  
Windows 2000, Windows XP  
Operating System  
Higher than Pentium III 900MHz  
Recommended CPU  
Memory  
64MB (Minimum)/ 128MB or more(Recommended)  
128MB or more for WindowsXP  
100MB or more  
HDD free area  
CD-ROM drive  
Drive equipment  
Support one of following resolutions;  
VGA (640 x 480), SVGA(800 x 600), XGA(1,024 x 768) Number of col-  
ors: Either of 16 bit (65,536 color 24/32 bit (16,77 million colors))  
Display setting of  
computer  
The computer must provide a 10Base-T or 100Base-TX network  
card.  
Network card  
Internet Explorer version 5.0, 5.5 or 6.0  
Netscape Navigator version6.2, 7.0 or 7.1  
* Used to control and set up the monitor. The layout of pages in the  
browser may slightly differ from each type of application or oper-  
ating system you use.  
Web Browser*  
Adobe Flash Player version 6,0,79,0(6.0r79) or later  
Plug-Ins  
- Microsoft Outlook  
- Netscape Mail  
* Required the internet e-mail application software to receive an  
e-mail alert sent from this product. If you do not use the function  
E-mail Alert, this application is not required.  
- Microsoft Outlook Express  
Internet Mailer*  
- FTP server (Windows 2000 Professional or Windows XP  
Professional)  
* The FTP service provided with the Windows 2000 Professional  
or Windows XP Professional is required when using the Network  
Viewer function.  
FTP Service *  
* For the operating environment of PJ Network Manager, refer to an owner's manu-  
al in the document CD-roM.  
PDa restriction  
1
The PDA can be used for the Light mode* only. The operating system of the PDA is  
PocketPC2002 or higher. The version of the Adobe Flash Player is 6,0,81,0 or higher.  
*1 The "Light Mode" and "Standard Mode" will be explained on item "Display Mode" ( p.30-32)  
11  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 1 Preparation  
*1  
the limitation of connection between this product and hub or computer  
Suitable LAN cables are limited by length and type as follows;  
Connection  
Type of usable LAN cable  
Maximum length  
100m  
2
Network Unit - Hub  
UTP Straight Cable with category 3 or 5 *  
2
Network Unit - Computer UTP Cross Cable with category 3 or 5*  
100m  
*1 There may be other limitations depending on your network environment or LAN specification.  
Please consult your network administrator for further details.  
*2 Category of LAN cable indicates the cable quality. Normally, a cable with category 3 or 5 is used  
for 10Base-T network, and a cable with category 5 is used for 100Base-TX network.  
Before use  
Package contains  
The package contains following items. Check each item as you unpack the package. If you  
have any of the following items missing, contact the sales dealer.  
Network unit  
1 piece  
T
C
A
K
N
I
L
Q
Guide  
u
ic  
k
S
e
tu  
p
Quick Setup Guide  
English  
1 piece  
1 piece  
Software CD-ROM  
NetworkViewer&Capture3software  
PJNetworkManagersoftware  
Document CD-ROM  
1 piece  
LD-NetOrganizerOwner'sManual  
PJNetworkManagerOwner'smanual  
1ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Before use  
Notice  
expression/abbreviation  
The word "monitor" found in this manual means "monitor provided with Network unit"  
unless otherwise noted.  
The OS of the computer and the Web browser described in this manual is Windows XP  
Professional and Internet Explorer 6.0. In case of another OS or Web browser, some instruc-  
tion procedures may differ from the actual operation depending on your computer envi-  
ronment.  
use of this manual  
This manual does not provide the description of basic operation and functions for com-  
puter, web browser, monitor and network. For instructions about each piece of equipment  
or application software, please refer to the respective booklet.  
trademarks  
Ethernet is a registered trademark of Xerox Corporation. Microsoft, Windows, Windows  
NT are registered trademarks of Microsoft Corporation. Internet Explorer is a registered  
trademark of Microsoft Corporation. Netscape Navigator and Netscape Communicator are  
trademarks or registered trademarks of Netscape Communications Corporation. JavaScript  
is a registered trademark of Sun Microsystems, Inc.  
Other product or brand names in this manual are registered trademarks or trademarks of  
their respective owners.  
* Unauthorized use of a part or whole of the contents in this manual is prohibited.  
* The contents of this manual are subject to change without notice.  
Basically this manual is described for Monitor set CE52LH1. Some instruction procedures may differ  
from the actual operation depending on the connected Monitor set type.  
1ꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 1 Preparation  
1ꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2  
2
Installation  
Describes how to install the network unit and software, and config-  
ure the network.  
15  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2 Installation  
Flow of installation  
The following are instructions for attaching this product to the monitor and connecting it  
to the network. Please review the entire procedure to become familiar with it.  
Function of the network unit ( p.17)  
Explains the name and functions of each part of the network unit.  
1
2
installation and network configuration ( p.18-25)  
1 Mount this product onto the monitor.  
2 Connect the LAN cable and join it to the network.  
3 Configure the network of the network unit.  
4 Set the Network PIN code.  
installation of the software ( p.26-28)  
Explains how to install the software Network Viewer & Capture 3 into your com-  
puter.  
3
set up is complete  
The preparation is completed to control the monitor connected to the network. At next  
step, set up and control the monitor via the network by using the web browser installed  
on your computer. Please see chapter 3 "Basic setting and operation". ( p.29)  
1ꢄ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Name and function of each part  
[1] Name and function of each part  
(top View)  
Power indicator  
Mounting screws  
Mount by using a coin etc. ( p.18)  
aCt indicator  
This turns on and off with green when  
sending or receiving of data  
LiNk indicator  
This lights up red when the network unit is  
connected to the network correctly.  
(Bottom View)  
Connector plug  
Connecting to the terminal on the  
monitor. ( p.18)  
serViCe 1  
Only for service use.  
serViCe 2  
Only for service use.  
LaN port  
Connecting the LAN cable. ( p.19)  
17  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2 Installation  
[2] installation and network configuration  
Mounting  
1 Disconnect the AC plug from the monitor.  
2 Remove the screws on the back of the cabinet, and then remove the terminal covers.  
3 Insert the network unit into  
the monitor, and fix it with the  
screws.  
!
Caution  
The AC cord must be disconnected from AC power outlet when mounting or removing this prod-  
uct. It may damage the product.  
Do not connect the AC cord until after connecting the LAN cable and computer.  
1ꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation and network configuration  
4 Set the Option Switch from the UP position to the DOWN position.  
Cannot use the serial port of the monitor in this position. Set back to the UP position  
when the network unit is not used.  
Up  
Position  
Down  
Position  
1ꢆ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 Installation  
Connection of LaN cable  
To connect to the network, it is required to use the UTP (Unshielded Twisted Pair) straight cable  
with RJ-45 plug. There are two different types of cables depending on whether the network is  
constructed with 10Base-T or 100Base-TX. Prepare the Hub (10Base-T or 100Base-TX) to distrib-  
ute the network cable if required.  
1 Disconnect the AC plug from the monitor.  
2 Connect the UTP straight cable to the LAN port on the network unit.  
3 Connect the UTP straight cable to the hub.  
Hub  
(10Base-T, 100Base-TX)  
Monitor  
UTP straight cable  
The AC cord must be disconnected from AC power outlet when connecting the cable. It may  
damage the product.  
When you set up the network which has a default setting by using computer, it must be carried  
out in the network which does not connect to other monitors.  
Use the UTP cross cable when you connect the computer and monitor directly not using the hub.  
When you connect the monitor into the 10Base-T network, use cable with category 3 or 5. When  
you connect the monitor into the 100Base-TX network, use cable with category 5.  
The length of cable between hub and monitor should be less than 100m.  
ꢀ0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installation and network configuration  
Network configuration  
When you connect a monitor to a network, the network number of monitor must be the  
same as the network you intend to connect. You should configure monitors network first.  
Make sure that the monitor is connected to the network correctly. To configure the net-  
work, use the computer. Refer to the chart below.  
Procedure of Connecting the monitor to the network  
Configure the network with computer  
p.22  
Please see further  
informatin on pages  
22-25.  
Temporarily set up the computer's  
network with the default network  
number of the LD-Net Organizer.  
Example of computer's configuration  
IP Address : 192.168.0.5  
Subnet Mask : 255.255.255.0  
Default Gateway : (blank)  
DNS : (blank)  
Restart the Computer, if required  
Please see further  
informatin on pages  
30-37.  
Using the web browser and login to  
the setting page of the LD-Net  
Organizer by accessing the default  
IP address.  
Default Network Address of the  
LD-NetOrganizer  
IP Address : 192.168.0.2  
Subnet Mask : 255.255.255.0  
Default Gateway : 0.0.0.0  
DNS : 0.0.0.0  
Change the network address you  
want to connect to the existing  
network through the setting menu  
on the browser.  
Example of monitor's configuration  
IP Address : 192.168.1.201  
Subnet Mask : 255.255.255.0  
DefaultGateway:192.168.1.1  
DNS : 0.0.0.0  
Restart the LD-Net Organizer  
Reset to the computer's original  
network configuration.  
Completing the network configuration. Perform the basic  
setting and operation of the monitor by using the web  
browser. Please see chapter "3: Basic Setting and  
Operation" on page 29 for further information.  
ꢀ1  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2 Installation  
Configure the network with the computer  
This example explains how to set the following configuration.  
IP Address  
Subnet Mask  
Default Gateway  
DNS  
: 192.168.1.201  
: 255.255.255.0  
: 192.168.1.1  
: 0.0.0.0  
The default network configuration is set as follows.  
IP Address  
Subnet Mask  
Default Gateway  
DNS  
: 192.168.0.2  
: 255.255.255.0  
: 0.0.0.0  
: 0.0.0.0  
Make sure that the monitor is connected to the network and then connect the AC cord to  
the outlet.  
1
1 Temporarily* set up your computer network configuration to the same IP network number  
as the LD-Net Organizer. For example, change your computer network configuration  
as follows and restart the computer.  
IP Address  
Subnet Mask  
Default Gateway  
DNS  
: 192.168.0.5  
: 255.255.255.0  
: (blank)  
: (blank)  
The network configuration of computer differs depending on each network environment  
or your computer. For further information, please see the chapter “Configure the network  
of computer” on page 24.  
*1 Change your computer's network configuration temporarily. After completing the set up for the  
monitor, you must set up again to the original network configuration for your computer. It is rec-  
ommended to make a note of those network settings.  
ꢀꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation and network configuration  
2 Configure the network of the monitor by using the web browser.  
1. Enter the IP address of the monitor as the  
URL. The login page will be displayed and  
login. For further information, please see  
chapter “3: Basic Setting and Operation” on  
page 29.  
2. Configure the network through the setting page on the browser. For further information, please  
see chapter “Network Configuration” on page 37.  
Completing of installation  
Now the installation is completed. The IP address of this monitor has been set to “192.168.1.201.  
You must reset the network configuration of the computer to the original and restart the com-  
puter.  
Next, please see chapter “Basic Setting and Operation” on page 30. It describes how to operate  
and set up the monitor.  
If you use a cable to connect the monitor and computer directly, without using a hub, you must  
use a UTP cross cable. In this case, you cannot access the login page if the setting of web browser  
is set to “Use proxy server”. It must be changed to the “Not use proxy server”. For further informa-  
tion, please see the “Web browser setting” of chapter "Appendix" on page 100.  
When you set up the network of monitor which has a default setting by using the computer, it  
must be carried out in the network which does not provide any gateways (routers).  
ꢀꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 Installation  
Configure the network of computer  
When you use the monitor through the network, the IP address of the monitor must have the  
same IP network number of the existing network. Also it is required to use the same IP network  
number of the computer to set up the monitor. In the network included with the gateway  
(router), it must be used with the IP network number specified by the gateway (router).  
Configure the computer's network by following steps:  
This example explains how to set the following network address.  
IP Address  
Subnet Mask  
Gateway Address  
: 192.168.0.5  
: 255.255.255.0  
: 192.168.0.1  
1 Select the Control Panel menu from the [Start] menu. Click  
the Network and internet Connection and then click the  
Network on the control panel.  
2 Click the Local area Connection icon with right button of  
the mouse and then select the Property menu. The right  
3 wSeinledcotwthweillGaepnpeearraol ntatbheosncrteheen."Local Area Connection  
Proper ties" dialog window. Selec t the inte rnet  
1
Protocol(tCP/iP)* and then press the Properties button.  
4 On the "Internet Protocol (TCP/IP) Properties" dialog win-  
dow, select the use the following iP address button and  
2
5 tEhnetenretnhteeDr tehfeauIPltagdadterewsasy* aadnddreSsusb. net mask.  
This setting is not needed if the network does not pro-  
vide the gateway (router).  
6 Click the ok button, the setting window will be closed.  
*1 Select the "TCP/IP" item of the LAN card you use. If the "TCP/IP" item is not listed in the column,  
you need to install the TCP/IP protocol. For further information refer to the user's manual of your  
computer.  
*2 If the network already has the TCP/IP protocol set, enter with the same IP network number for the  
IP address and Subnet mask.  
*3 There are some ways to set up the network depending on your computer's appearances.  
ꢀꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation and network configuration  
Network PiN code setting  
The Network PIN code can be set to restrict access to the setting page of the monitor  
using the web browser.  
Default Network PiN code [0000] means no Network PiN code is set.  
It is recommended to set up the Network PIN code when you connect the monitor to the net-  
work. This setting is carried out through the web browser. For further information, refer to item  
"Initial setting/Network PIN code setting" ( p.35).  
Notice about system construction  
For installation of multiple monitors into the same network with network  
unit.  
Do not install multiple monitors with network units that have their default network set-  
tings to the same network. The use of the network units which have the default IP address  
set to the same network settings will cause IP addresses to collide and create a malfunc-  
tion. When you install multiple monitors into the same network, configure the network  
with the following steps.  
1. Change the IP address from the default IP address. Please see item "Network configura-  
tion" for further information ( p.21).  
2. Make sure that there is no network equipment set with the same IP address in the net-  
work before connecting to the network.  
3. When installing other monitors, follow the above steps to change the IP address and  
connect to the network.  
in case of installing the monitor with network unit into the network con-  
structed with the DHCP/BootP server.  
This network unit does not support the DHCP/BOOTP server. The static IP address must be  
manually configured. To use this product in this network environment, set it up so that the  
DHCP/BOOTP server does not assign the IP address configured to this product for another  
device on the network. Please consult your network administrator for further information.  
ꢀꢃ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 2 Installation  
[3] installing the software  
It is required to install the software into your computer to use the Network Capture func-  
tion and Network Viewer function. Please install the software as follows.  
Note: to install the software into the computer with windows 2000, windows XP  
or windows Nt, you should logon as administrator. Before installation, make  
sure that the other applications are closed, otherwise proper installation  
cannot be made.  
Network Viewer & Capture 3 installation  
1 Set the supplied Network Viewer & Capture  
3 CD-ROM into the CD-ROM drive of your  
computer. Double click setuptool.exe icon  
in the "Tool" folder in the CD-ROM.  
2 Select "English [United States]" from the  
pull-down menu on the "Choose Setup  
Language" window and click ok button to  
start installing and then follow the installa-  
tion wizards.  
As the "License Agreement" will appear, read  
contents carefully and click Yes button if you  
agree to the license agreement to proceed  
with installing.  
ꢀꢄ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Installing the software  
installed software  
The following 3 software are installed on your computer.  
c Network Capture 3:  
Capture the displayed image of the computer and serve it to the monitor via the net-  
work.  
This software is registered into "startup folder" of the computer and the capture icon  
stays on the task bar after booting the computer.  
c Network Viewer 3 (File Converter 1):  
1
Converts to the JPEG* data format which can be displayed with the monitor from the  
JPEG, bitmap and Power Point files.  
c Network Viewer 3 (Program Editor) :  
This is a tool to make the program which has a function to specify and order the display-  
ing JPEG image data stored in the file servers.  
* To uninstall these software, use "Add/Remove Program" from the control panel.  
*1 This product supports the JPEG image format. This file is needed to convert to the optimized JPEG  
file by using the File Converter 1 software previously. Refer to the item "Creating the available data  
[Network Viewer 3]"( p.82) about data converting for the display.  
ꢀ7  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 2 Installation  
File Converter 2 installation  
1 Set the supplied Network Viewer & Capture  
3 CD-ROM into the CD-ROM drive of your  
computer. Double click setupDrv.exe icon  
2 iSnetlheect"D"Erinvegrl"isfohld[UerninitethdeSCtDat-eRsO]"Mf.rom the  
pull-down menu on the language selection  
window and then click install button to start  
installing.  
installed software and places  
Network Viewer 3 (File Converter 2) is installed in the  
"Printers and Faxes" folder in the "Control Panel".  
c
Network Viewer 3 (File Converter 2):  
This is a kind of the printer driver to convert  
to the JPEG data optimized to display by the  
monitor from any of the documents created by  
the application software.  
* To uninstall Network Viewer 3(File Converter 2), just delete the "Network Viewer 3(File Converter 2)"  
icon from the "Printers and faxes" folder.  
ꢀꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 3  
3
Basic Setting and Operation  
Describes basic operations and settings for controlling the monitor  
by using the web browser. It is required that computer and monitor  
is connected to the network and the network address is properly  
configured.  
29  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 3 Basic Setting and Operation  
Login the setting page of the monitor  
1 enter the iP address  
Launch the web browser installed in your  
computer, enter the IP address into the  
"Address" on the browser and then press  
"Enter" key.  
Enter the address that you configured in  
item "Network configuration" ( p.21).  
The default IP address is [192.168.0.2].  
2 select a display mode and login  
This product provides 2 types of control mode, Standard Mode and Light Mode as the  
below. Select a proper mode to match your PC and network environment by click-  
ing on the text link. Once you select your desired display mode, the setting page you  
selected display mode will be displayed automatically from the next login. To change  
the display mode, click "Top" on lower-right corner of the setting page ( p.31).  
STANDARD MODE  
For computer display, displays  
graphical menus and settings. This  
mode is recommended for standard  
use.  
LIGHT MODE  
Displays with 200 x 300 dots. This  
mode is optimized for use of the  
handheld computer, PDA, etc. It is  
also convenient if the network traf-  
fic is heavy. (This mode has some  
limitations on the network viewer  
and multi-control functions.)  
If the setting page has set the password, the  
authentication window will appear. In this case type  
"user" onto the user Name text area and the login  
Network PIN code onto the Password text area and  
then click ok button.  
* The entering User Name must be "user" and it can not be  
changed.  
[Note]  
When accessing the monitor for the first time or the  
Network PIN code "0000" is set, the auto-login will be per-  
formed and the next main setting page is displayed.  
ꢁ0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Login the setting page of the monitor  
3 Display of main setting page  
The following main setting page will be displayed according to your display mode  
selection. Perform various kinds of settings through this page. Click on the menus to dis-  
play the control and setting pages.  
1 Main setting page in the Standard Mode display  
Clock display  
Display on or off by  
clicking text ON or  
OFF  
sub menu tab  
Switches the sub  
menu tab.  
Page numbers  
Switches the pages  
by clicking the  
number's tab.  
Returns to Display  
Mode selection  
page ( p.30)  
setting page  
Main menu  
For selection of control and  
setting items of the monitor.  
Displays the control and  
setting items according to  
the selected menu.  
this standard mode display is mainly used through this manual for the setting and  
control description.  
If your computer does not have the Adobe  
Flash Player version 6 or later, follow to the  
message on the control page to install the  
Adobe Flash Player. For further product  
information or installing, see the Adobe  
homepage.  
http://www.adobe.com  
ꢁ1  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 3 Basic Setting and Operation  
2 Main setting page in the Light Mode display  
Sub menu tab  
Page numbers  
Returns to the display mode selec-  
tion page.  
Setting page  
Main menu  
The blank page appears if your PDA does not provide a  
Adobe Flash Player. You need to install the Adobe Flash  
Player. ( p.31)  
the network viewer function in the Light mode has following limitation;  
- Cannot select the program or folder for the display ( p.91, p.93)  
- Cannot check up the images in the folder or program ( p.94).  
How to use the setting page  
To control and set up the monitor, use the setting menus on the web browser. Describes the  
basic operation and procedures commonly used on this manual.  
example of the setting Page  
The setting pallet appears when clicking the item.  
Change the value by clicking d or e button, or type  
the number onto the text box directly and then click  
set button.  
* Each item has a valid setting range respectively.  
Setting Pallet  
The value in the text box indicates current value.  
Each item has a valid setting range. The setting value exceeding this becomes invalid. Some con-  
trol items can not be used depending on the selecting input mode or functions of the monitor  
you use. In this case, the values of those items are indicated with "---".  
ꢁꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
How to use the setting page  
type of the setting pallet  
text box setting  
Enter a number or text and  
then click set button.  
or  
Change a value with d or e  
button and then click set but-  
ton.  
The value changes quickly  
when keeping pressing d or  
e button.  
Pull-down menu setting  
Select an item with pull-down  
menu button and then click  
set button.  
radio button setting  
Select an item by selecting a  
radio button.  
Check box setting  
Select items by ticking on  
check boxes.  
ꢁꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3 Basic Setting and Operation  
initial setting  
After installing this product to the monitor, perform the following basic ini-  
tial setting.  
Click initial setting on the main menu to display the initial setting page.  
The model name of the monitor on which this product is mounted is displayed on the  
page.  
item  
Description  
Model name.......Indicates the model name of the monitor pro-  
vided with the network unit  
Network PIN code ......Sets the Network PIN code to login the setting  
page ( p.35).  
Temperature.......Switches display temperature unit Centigrade or  
Fahrenheit.  
!
Caution  
use of Battery  
This product provides a lithium battery. When the battery runs down, the clock and timer functions  
do not operate properly. Contact your local dealer for the replacement of battery. The replacement  
must be carried out by a qualified service personnel.  
ꢁꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Initial setting  
Network PiN code setting  
This is to set the Network PIN code to restrict the access from  
an unauthorized person through the network.  
Enter a 4-digit number as the Network PIN code onto the text  
box and click set button.  
The network unit begins restarting and it takes about 20 sec-  
onds. Close (Quit) the web browser and access to the login  
page again in 20 seconds. This is to perform the login authentication firmly.  
The default Network PIN code [0000] means no Network PIN code is set.  
When you connect the monitor with this product to the network, it is recommended to set a new  
Network PIN code. Only a four-digit number is valid for the Network PIN code.  
Valid characters for the Network PIN code are only numbers 0 to 9. The number "0000" means no  
Network PIN code is set.  
This Network PIN code is not to restrict the use of the monitor. This Network PIN code is to set the  
security against the use of the monitor through the network.  
If you forget the Network PIN code to the monitor, you can initialize PIN code and IP Address/Sub  
net/Gateway/DNS by selecting "Network initial" from "Installation mode" menu on the monitor.  
For further information, please see instruction manual of the monitor.  
ꢁꢃ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 3 Basic Setting and Operation  
item  
Description  
Time setting........When clicking auto button, the date and time  
set on your computer are set to the network unit  
Current time.......Indicates current date and time set on the net-  
work unit  
Date..........................Sets date in manual  
Time..........................Sets time in manual  
Date and time setting  
auto setting  
Click auto button on the page, the date and time set on your computer are set to the  
network unit.  
Note:  
Confirm that your computer has a correct clock time before performing the auto time setting.  
Manual setting  
Click item Date or time and enter date or time on the input box with adequate format.  
Date is in year/month/day format.  
ex. 2006/04/25  
Time is in 24-hour:minute format.  
ex. 18:30  
ꢁꢄ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Network configuration  
Network configuration  
Click Network on the main menu. The following setting page is displayed.  
The IP Address, Subnet Mask, Default Gateway, DNS (Domain Name Server)  
and monitor name are set up on this setting sub menu.  
The IP address and Subnet Mask have been configured already in chapter "Installation".  
If you want to change them or configure default gateway or DNS, perform them in this  
page. If you change them, the network unit begins restarting and it takes about 20 sec-  
onds. Close (Quit) the web browser and access to the login page again in 20 seconds.  
item  
Description  
IP address.............Sets IP address of the monitor  
Subnet mask.......Sets Subnet mask. Normally sets 255.255.255.0  
1
Default gateway* .....Sets IP address of the default gateway (Router)  
2
DNS* .......................Sets IP address of the DNS server. Must be set  
when using the e-mail function  
3
Monitor name* ...Sets name of the monitor. (64 characters maxi-  
mum)  
You must use the number specified by your administrator. The  
address must be entered as a group with four numbers split by a  
dot like [192.168.001.101].  
*1 Set [0.0.0.0] if the network does not provide the gateway (router).  
*2 Set [0.0.0.0] if you do not use the function E-mail alert.  
*3 If you use the DNS server, register the host name registered to the DNS server as a monitor name.  
You can access with this monitor name from any computers in your network. If you do not use  
the DNS server, access with the assigned IP address to the monitor.  
* All the network setting will reset to the default when setting [0.0.0.0] of the IP Address.  
ꢁ7  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 3 Basic Setting and Operation  
e-mail setting  
This product has an E-mail function which can send an alert message to  
users or an administrator if it detects an abnormality on the monitor. Click  
e-mail setting on the main menu and follow the below steps.  
item  
Description  
1
SMTP server* .....Sets server name or IP address of the SMTP server  
Administrator  
address...................Sets e-mail address of administrator  
Add e-mail  
address...................Sets e-mail address of the user to send mail when  
the monitor has an abnormality.  
1 Setting SMTP server and administrator address  
1
Set the server name or IP address of the SMTP server* and administrator address. The  
administrator address is set to "Reply-To" address of the message sent from the monitor.  
*1 The SMTP server is a server for sending E-mail. Please contact your network administrator to  
have this SMTP server address.  
If the network unit sends an alert message due to the abnormality on the monitor but the SMTP  
server is down in some other reason, the message will not be sent. In this case, the message  
"Unable to connect to server." will be displayed on the setting page. To clear this message, set up  
SMTP server address again.  
To use the E-mail function, it must be set the DNS address on the Network setting page correctly.  
You cannot use this E-mail function if the DNS server and SMTP server cannot be used in your net-  
work environment.  
ꢁꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
E-mail setting  
2 Registering and deleting E-mail addresses  
Click "Add e-mail address" and type the e-mail address  
onto the text box and click set button. To check the  
registered addresses, click Check/Delete sub menu tab.  
The addresses are listed as the figure on the right.  
Up to 10 E-mail addresses can be registered.  
Check / Delete  
To delete the registered addresses, check the address you  
want to delete and click Delete button.  
3 Option selection for sending alert mail  
Click option sub menu tab. Check the condition items  
under which alert mail will be sent and click set button.  
Please refer to item "Examples :Type and contents of alert  
mail" described on the next page.  
[1]––––––––––––––––––––––––––––––––––  
When power circuit is failed.  
Option  
When internal temperature is too high.  
When internal fan circuit is failed.  
When Panel usage time reaches [ ] hours.  
[2]––––––––––––––––––––––––––––––––––  
W
hen monitor is turned off.  
When power save function turns Monitor off  
When the signal is interrupted  
When Auto Play is failed  
.
.
.
If condition "When Auto Play is failed" is  
checked, the trap is sent when occurring the  
error during the auto display operation using  
with the network viewer function ( p.92).  
For further information of the error, refer to  
item "Auto Display setting and control page  
[3]"( p.95).  
Up to 99,999 hours can be set for use time.  
If condition "When monitor is turned off" is  
checked, the trap is sent when the monitor  
is turned off except Power/Fan fail, High  
temp, Power save.  
ꢁꢆ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3 Basic Setting and Operation  
examples: type and contents of alert mail  
When the monitor has an abnormality, the following alert messages are sent to the regis-  
tered E-mail address according to your selected condition. Administrator or user can take  
an efficient action quickly by receiving this message. This is very useful to maintain and  
service the monitor.  
The following are examples of received messages.  
c When power circuit is failed:  
TITLE: Message from monitor  
10-03-2005 00:59  
Monitor Model Name: model name  
TCP/IP: 192.168.1.201 Monitor Name: Lcd05  
It sends you following message.  
* Error! Power circuit has failed.  
The monitor was turned off, because the monitor power circuit failed.  
Unplug the monitor from AC outlet and ask servicing to a qualified service personnel with  
the error information.  
c When internal temperature is too high:  
TITLE: Message from monitor  
10-03-2005 00:59  
Monitor Model Name: model name  
TCP/IP: 192.168.1.201 Monitor Name: Lcd05  
It sends you following message.  
* Error! Internal temperature is too high, please check unit.  
The monitor was turned off, because the monitor internal temperature rose too high.  
Unplug the monitor from AC outlet and ask servicing to a qualified service personnel with  
the error information.  
c When internal fan circuit is failed:  
TITLE: Message from monitor  
10-03-2005 00:59  
Monitor Model Name: model name  
TCP/IP: 192.168.1.201 Monitor Name: Lcd05  
It sends you following message.  
*Error! Internal fan circuit has failed, please check unit.  
ꢂ0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
E-mail setting  
c When panel usage time reaches [ ] hours:  
TITLE: Message from monitor  
10-03-2005 00:59  
Monitor Model Name: model name  
TCP/IP: 192.168.1.201 Monitor Name: Lcd05  
It sends you following message.  
*Information! Panel usage time has reached "****" hours.  
The network unit sends this message when the panel usage time reaches the preseted  
time.  
c When power save function turns Monitor off:  
TITLE: Message from monitor  
10-03-2005 00:59  
Monitor Model Name: model name  
TCP/IP: 192.168.1.201 Monitor Name: Lcd05  
It sends you following message.  
*Information! Power save function turns Monitor off.  
c When the signal is interrupted:  
TITLE: Message from monitor  
10-03-2005 00:59  
Monitor Model Name: model name  
TCP/IP: 192.168.1.201 Monitor Name: Lcd05  
It sends you following message.  
*Information! The signal is interrupted.  
ꢂ1  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3 Basic Setting and Operation  
sNMP setting  
This product provides a SNMP (Simple Network Management Protocol)  
agent function. The SNMP consists of a manager and agents. The group  
which communicates information each other with SNMP is called  
"Community". There are two access modes in a community, Refer (read only) and Set (read-  
write). This product allows to use Refer (read only) only. The SNMP message informs the  
monitor status called "Trap" to an administrator. Click sNMP setting on the main menu and  
set up each item.  
Monitor information  
item  
Description  
Contact.................Enter user name of the monitor etc. (optional)  
Place .......................Enter place of the monitor (optional)  
Community  
name(refer).......Enter community name (read only). Default name  
is "public".  
The SNMP agent provided with this product is based upon MIB-2 defined by RFC1213. For private  
MIB information, refer to file "Mibinfo/52LdNet.mib" in the CD-ROM.  
ꢂꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
SNMP setting  
Trap  
item  
Description  
Community name......Enter community name to send "Trap". Default  
name is "public".  
Trap address.......Enter IP address of the SNMP manager computer  
to receive "Trap".  
Trap check/delete  
Check and delete the trap address  
Checking the registered trap address and deleting the  
address.  
To delete the address, tick check box in front of the IP  
address and click Delete button.  
Up to 10 trap addresses can be registered.  
ꢂꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 3 Basic Setting and Operation  
Trap option  
trap option setting  
Tick check boxes in front of the condition item to send the  
trap.  
Click set button if you tick or un-tick the check box on a page.  
[1]––––––––––––––––––––––––––––––––––  
When power circuit is failed.  
When internal temperature is too high.  
When internal fan circuit is failed.  
When Panel usage time reaches [ ] hours.  
[2]––––––––––––––––––––––––––––––––––  
W
hen monitor is turned off.  
When power save function turns Monitor off  
When the signal is interrupted  
When Auto Play is failed  
.
.
.
Up to 99,999 hours can be set for the time setting.  
If condition "  
W
hen Auto Play is failed" is checked, the trap is sent when occurring the error during the  
auto display operation using with the network viewer function ( p.92). For further information of the  
error, refer to item "Auto Display setting and control page [3]"( p.95).  
ꢂꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4  
4
Controlling the Monitor  
Describes controlling and setting of the monitor by using the web  
browser.  
45  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 4 Controlling the Monitor  
Power control and status check  
Click Power & status on the main menu. The control page will be dis-  
played.  
By clicking oN or standby button on the page, the power of the monitor can be con-  
trolled.  
Confirmation window  
as shown in the below  
appears when the  
standby button is pressed.  
Popup confirmation window  
item  
Description  
Monitor status  
Power .........................Displays the status of the monitor. (ON, OFF)  
Status ..........................Displays the status of the monitor's power.  
Power control........Controls the monitor power by clicking the "ON" or "Standby" button.  
Monitor temperature  
Inside temperature ....Displays the internal temperature of the monitor.  
* The temperature unit can be set either Centigrade or Fahrenheit in item "Initial  
setting". ( p.34)  
ꢂꢄ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Power control and status check  
ꢂ7  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4 Controlling the Monitor  
Controls  
Click Control on the main menu. The setting method differs depending on the contents  
of the page. Click on the page number to change pages and select desired setting items.  
Please see the instruction manual of the monitor to have the further information  
of each control item.  
input  
This function is to select the input mode and source mode of the monitor. Click set but-  
ton after selecting the input and source mode.  
item  
Description  
Input.......................Selects input mode of the monitor.  
AV 1  
RGB  
AV 2  
AV 3  
PC  
DVI  
NETWORK  
Source.....................Selects signal source of the input.  
AV 2 : YPbPr/RGBHV  
The control page displays valid control items depending on the selected input mode, signal ,  
therefore, there may be different controls between the described items and actual control items  
on the page display. For further information , refer to the monitor's owner's manual.  
When the monitor is in standby, only the timer on the setting menu is effective; others are inactive.  
ꢂꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Controls  
Picture adjustment  
This function is to adjust the displayed picture image.  
item  
Description  
Contrast.................Adjusts picture contrast  
Brightness............Adjusts picture brightness  
Color.........................Adjusts picture color saturation  
Tint............................Adjusts picture hue  
Sharpness.............Adjusts picture sharpness.  
item  
Description  
White Tone...........Sets a white tone mode. ( Cool, Standard, Warm,  
Personal)  
Picture Mode......Sets a picture mode. (Standard, Dynamic, Soft, Eco,  
Personal)  
item  
Description  
DCDi............................Switches DCDi (Directional Correlational  
Deinterlacing) mode. (Off, On)  
ACC/ACM............Switches ACC/ACM (ACC: Adaptive Contrast  
and Color; ACM-II: Active Color Management-II)  
mode. (Off, Vivid, Cinema, Sport)  
CCS.........................Switches CCS (Cross Color Separation) mode. (Off,  
Auto, Standard)  
DNR........................Switches DNR (Digital Noise Reduction) mode.  
(Off, Auto, Low, Mid, High)  
MPEG NR..................Switches MPEG NR (MPEG Noise Reduction)  
mode. (Off, On)  
Film mode...............Switches Film mode (Inverse 3:2 pulldown):  
mode. (Off, On)  
ꢂꢆ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 4 Controlling the Monitor  
sound  
This function is to adjust the sound of the monitor. The values in the text box represent  
the current control value or status.  
item  
Description  
Volume...................Adjusts the sound volume.  
Mute.........................Suppresses the sound. (ON, OFF)  
ꢃ0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
PC adjustment  
PC adjustment  
Click PC adj. on the main menu. This function is to adjust the signal from  
the computer connected to the monitor to obtain the proper picture  
image on the screen.  
item  
Description  
Auto PC adj............Performs automatic adjustment.  
H-Position.............Adjusts the horizontal position of the screen.  
V-Position.............Adjusts the vertical position of the screen.  
Clock ........................Eliminates flicker from the image.  
Phase...........................Eliminates disorder from the image.  
ꢃ1  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 4 Controlling the Monitor  
setting up the monitor  
Click setting on the main menu. This function is to set up the monitor.  
Select the sub menu [Screen setting], [Setting] or [Tile Mode] and then set  
up each setting.  
item  
Description  
Wide ........................Switches the screen mode. (Full, Zoom16:9,  
Title16:9, Zoom14:9, Title14:9, Normal, Natural)  
There may not be available mode depending on  
the input mode.  
ꢃꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Setting up the Monitor  
item  
Description  
Freeze.....................Sets the image to freeze mode.(ON, OFF)  
Child lock.............Sets child lock mode. (ON, OFF)  
RC Inhibition......Sets remote control inhibition mode. (ON, OFF)  
Initial setting.........Sets all of the monitor control items to the fac-  
tory default setting except for Installation mode .  
* This function is not effective for the settings  
of the network unit (Network address settings,  
e-mail settings, etc.)  
ꢃꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4 Controlling the Monitor  
item  
Description  
Tile Mode Active...Sets tile mode active. (Off, On)  
H-Sets........................Sets to divide the horizontal picture.  
V-Sets.........................Sets to divide the vertical picture.  
H-Location...............Select one part of the horizontal picture.  
V-Location...............Select one part of the vertical picture.  
Bezel H Adjustment..Adjusts the horizontal picture for smooth image.  
BezelV Adjustment...Adjusts the vertical picture for smooth image.  
refer to the monitor's instruction manual for operation of the tile mode.  
ꢃꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Timer Setting  
timer setting  
This page is to set the timer to turn the monitor off or on at a programmed  
day/date and time. Follow the steps below for setting.  
Click timer on the main menu.  
Present time set on the  
network unit  
Select date  
Select day  
Set execute time  
Event  
action  
How to set the timer  
1 Set a day or date  
to set the timer event at same time everyday or every week,  
Select day entry with radio button and then select desired day with the pull-down menu  
button.  
The selectable days are as follows:  
- same time everyday  
- every week ( days from Monday to sunday)  
to set the timer event on specified date,  
select date entry with radio button and then type the date with (Year/Month/Date) for-  
mat.  
ex.: type [2005/12/20] if you specify [December 20, 2005].  
ꢃꢃ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 4 Controlling the Monitor  
2 Set an execute time  
Type the time with (Hour:Minute) and 24 hours format.  
ex.: type [18:25] if you specify [PM 6 o’clock and 25 minutes].  
3 Select an event action  
Select an event action from the pull-down menu.  
event  
action  
ON..................................Turns on the monitor  
OFF................................Turns off the monitor  
*Available events depends on the monitor function.  
4 Register an event  
Click set button to register the set timer event. Repeat steps 1 to 4 for another timer  
event setting.  
Check the timer events  
To check the set timer events, click Check button. The timer  
events are listed. The event with blue background color rep-  
resents the timer-OFF event.  
Change the event mode  
On the event list appearing by clicking Check button, click  
on the event you want to delete, disable or enable. Click  
Cancel, Delete, timer oN or timer oFF button on the  
popup pallet.  
Button  
operation  
Cancel......................Cancels the setting  
Delete......................Deletes the timer event  
Timer OFF.............Disable the timer event temporarily  
Timer ON...............Enable the timer event  
ꢃꢄ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Timer setting  
Notes on timer setting  
Up to 10 timer events can be registered. Timer events always operate according to the next valid  
event depending on the monitor's power status. In the example below, event 3 turns on the moni-  
tor so next event 4 (also turning on monitor) will not be effective because the monitor is already  
turned on. Similarly, when the monitor is turned off by event 5, event 6 OFF will not be effective  
in turning it off again. But these secondary events (event 4 and event 6) will become effective if a  
person turns off the monitor (after event 3 and before event 4) or turns on the monitor (after event  
5 and before event 6).  
Invalid event  
Invalid event  
OFF  
OFF  
ON  
OFF  
ON  
Monitor  
Event 1  
Event 2  
Event 3  
Event 4  
Event 5  
Event 6  
ON  
OFF  
ON  
ON  
OFF  
OFF  
Time  
When the timer events are set at the same time, the last event set will override the previous  
events. For example, if there is an event like "ON at 8:00 everyday" and then new event is set like  
"OFF at 8:00 everyday", only the last setting event is effective.  
The timer operates by using the clock function provided in this product. Before setting the timer,  
please confirm that the current date and time are set correctly. Timer and clock functions are func-  
tioning using a lithium battery provided in this product. When the battery runs down, the clock  
and timer functions will not operate correctly. Consult your local dealer for the replacement of bat-  
tery. The replacement must be carried out by a qualified service personnel.  
ꢃ7  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 4 Controlling the Monitor  
Monitor information  
This page is to display the basic information of the monitor status. Click  
information on the main menu.  
items  
Description  
Input.........................Displays selected input and source.  
System....................Displays selected signal system.  
Signal.......................Input signal status (Yes, No)  
Wide.........................Displays screen mode.  
Panel time..............Displays the panel use time.  
Timer........................Displays the timer status (ON, OFF)  
Click this button to  
update the information  
ꢃꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Multi-control  
Multi-control  
Controlling and setting the multi-monitors  
This function enables you to control the multiple monitors equipped with  
the network units that are connected to the network. Click Multi Control on the main  
menu to display the control page.  
Note:  
to control the multiple monitors, each monitor must have the same Network PiN code.  
example of multi control  
MONITOR 1  
MONITOR 2  
MONITOR 3  
MONITOR 4  
PC6  
PC5  
PC4  
Select Input2 for  
MONITOR 1 to  
MONITOR4.  
ꢃꢆ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 4 Controlling the Monitor  
start/stop the multi control  
To start or stop controlling the multi-monitors, click  
Multi control setting menu and select ON or OFF.  
Switches on and off the  
multi-control function  
Multi control setting  
OFF........Stops multi control function  
ON..........Starts multi control function. The multi control  
menu will appear when setting ON. These  
items of menu are linked to the main menu.  
The multi controllable menus are "Power & Status", "PC  
adjustment", "Control", "Setting", "E-mail setting", "Timer",  
"SNMP setting" and "Network Viewer". Click each menu  
and perform setting and adjustment.  
The word "MULTI CONTROL" appears on the each control  
page while the multi control is operating.  
This shows the multi con-  
trol is operating now.  
ꢄ0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Multi-control  
register the monitor  
To use the multi control function, register the IP address of the monitor you intend to con-  
trol. Click registration sub menu tab and set the IP address, Memo and Multi control item,  
then click set button.  
items  
Description  
IP address............Enter IP address of the monitor to control  
Memo.....................Enter monitor name or installed location etc.  
Multi control item  
Control.............. Controlling the monitor  
Both control .. Controlling and displaying images  
Visual control .... Displaying the images  
Confirmation of registered monitor  
To check the registered information, click Check & Change  
sub menu tab. The registered information of the monitor is  
listed as the below.  
* When you click on a listed IP  
address, the login page for the  
selected monitor will be displayed  
with a new window.  
* The word "none" is displayed if not using the "Memo" func-  
tion.  
IP address  
Status  
Memo  
Page no.  
Click here to close  
the sub menu Check  
& Change.  
10 monitors per page can be registered and up to 100 sets can be registered for the multi-control.  
ꢄ1  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 4 Controlling the Monitor  
Change the mode of the registered monitor  
To change the mode of the registered monitor, select a mode with the pull-down menu  
button under the IP address of the target monitor and then click set button.  
Mode  
operation  
Control.................... Controlling the monitor  
Both control........ Controlling and displaying pictures  
Visual control.......... Displaying the pictures  
OFF............................ Excluding from the multi-control  
Delete...................... Deleting from the multi-control  
* The multi control item is not changed during using the  
network viewer function. It is not available with the light  
mode.  
status  
If some of the registered monitors are disabled by some  
reasons (such as disconnecting the power source, dis-  
connecting the LAN cable, disconnecting from the net-  
work), control changes will continue to be effective for  
the monitors that are still active. At the same time, the  
deactivated monitors are excluded from the multi-con-  
trol. The status of the registered monitors are indicated  
under the monitor name. See the table below for status  
indications.  
Status  
status  
Description  
(blank).....................The monitor is connected to the network correctly  
No connect..........The monitor may not be connected to the network. Please check the connection  
and network configuration of this monitor.  
PIN code error.............The PIN code is incorrect. The PIN code for the multi-controlled monitors must be  
the same. Change the PIN code of this monitor to the common PIN code.  
File Error................. Not displaying the images. Check if this monitor is using the Network Capture func-  
tion or Network Viewer function individually, or in the standby mode.  
* The network unit updates the status at the time when the multi-control function was executed.  
If the multi-controlled monitor is in the standby mode, any change is not effective except timer  
setting.  
Cannot register, delete or change the multi-control setting during using the network viewer func-  
tion.  
It is recommended that a specified monitor should be chosen for setting as a master when you  
use this multi-control function. The control for the multi-controlled monitors will become too  
complicated operation if this function is used for each monitor.  
If the registered monitor is not connected to the network, it will take some time to complete the  
multi-control operation because of waiting for the response from each registered monitor.  
There are some disabled items in the multi-control function for the light mode.  
ꢄꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Multi-control  
Check & Change page in the light mode  
Following functions in the "Check & Change" page are  
not available in the light mode.  
- Changing the control mode.  
- Deleting the registered IP address  
- Indicating the each status  
- Indicating the each memo  
This indicates that the  
mode is "VisualControl".  
This indicates that the  
mode is "Control".  
Connection status  
Blinking: Connected  
Gray: Disconnected  
(Check & Change page in the light mode)  
Controlling all together  
"Power & Status", "PC adjustment", "Control" and "Setting"  
can be controlled all together. Set "ON" the multi control  
setting and adjust controls of each menu. The setting  
value is applied to the registered monitors sequentially .  
This is effective only if the multi control item of the regis-  
tered monitor sets to either "Control&Image" or "Control".  
setting all together  
"E-mail setting", "SNMP setting" and "Timer" can be set all  
together. Set "ON" the multi control setting and items of  
each menu. The setting value is applied to the registered  
monitors sequentially.  
This is effective only if the multi control item of the registered  
monitor sets to either "Control&Image" or "Control".  
ꢄꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 4 Controlling the Monitor  
Multi-control  
Viewer auto setting all together  
"Viewer auto display" can be set all together. Set "ON" the  
multi control setting and select [3] auto display setting  
from Viewer sub menu (selected by "Multi-control" -  
"Network Viewer" menu). Set the display time periods and  
repeat times for the auto image display. When clicking  
start button, the registered monitors start playing back  
the auto image display in sequential.  
For further information of the Auto display, see "Using the  
network viewer function". ( p.92)  
This is effective only if the multi control item of the registered  
monitor sets to either "Control&Image" or "Image".  
ꢄꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 5  
5
Network Capture  
Network Capture is a function to display the screen image of the  
computer via the network.  
- Real Time Capture  
- Network Communication  
65  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 5 Network Capture  
about Network Capture function  
The Network Capture is a function to display the screen images of the computer which  
has a Network Capture 3 software by the monitor through the network. This function has  
2 kinds of mode as the below.  
- Real Time Capture ( p.68)  
A function to display the screen image of the computer by the monitor through the  
network in real time.  
- Network Communication ( p.ꢀ1)  
This mode is to communicate by sharing the capture image of a computer with multiple  
computers and a monitor. User can draw the text and figure on the captured image by  
using a drawing tool.  
Up to 30 computers can be registered.  
The Network Capture function cannot be used when using the Network Viewer function. The  
Real Time Capture and Network Communication mode cannot be used at the same time.  
Launching the Network Capture 3  
After installing the Network Capture 3 software, the shortcut icon is copied into the  
"Startup" folder. When you boot the computer, the Network Capture software also starts  
and its icon stays on the task bar. If the icon is not appeared on the task bar, the Network  
Capture 3 software is not starting. Click "Network Capture 3" from "Start" - "All the  
Programs" - "Network Viewer & Capture 3" menu to launch it manually. The status which  
the Network Capture 3 icon stays on the task bar is just preparing the screen capturing.  
Commands on the task bar  
When clicking the Network Viewer & Capture 3 icon  
on the task bar, The popup menu will appear as the  
right. See the next page for each operation.  
ꢄꢄ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
About Network Capture function  
items  
Description  
Start real time capture..................Starts the real time capturing. ( p.68) The screen image of the computer is  
displayed on the monitor in real time.  
Start communication ....................Starts the Network Communication. ( p.71) Captured image is displayed  
on the monitor. The captured image edit window appears on the computer  
screen.  
Parameter set up............................Sets the communication parameter between the computer and network  
unit of the monitor. For further information, see item "Parameter set up"  
below.  
Version information.......................Displays the version of this software.  
Shut down ......................................Quits the application.  
Parameter set up  
1 Click Network Capture 3 icon on the task bar.  
2 Click "Parameter set up" on the popup menu. The set-  
ting window will appear.  
3 Set Capture Port and PiN code to match to the  
monitor’s port number and Network PIN code.  
To check the Capture Port number, see item "Control by  
the web browser" ( p.70). To check the PIN code, see  
item "Network PIN code setting" ( p.35).  
Specify the port number of TCP/IP. The default port set-  
ting is 9000. There are some reserved port numbers and  
also some applications may use their own port numbers.  
If one of those port numbers is used, the alert dialog  
window will appear and let you know that it is an invalid  
port number. In this case, use another port number.  
The reserved port numbers are http (80), ftp (21), telnet  
(23), etc. The port no. 4352, 10000, 10001 are reserved to  
control the monitor through the LAN port.  
4 Click search button to list up the available IP address  
assigned to the monitor and select desired IP address you use, or you can enter the IP  
address or host name manually if you know that IP address or host name.  
It may not find any address over the router. Consult your network administrator for further  
details.  
5 Set the quality of the image.  
Quality: Selects from High, Mid, Low  
Image Scaling: If checked, the screen image size of the computer is automatically adjusted to the  
monitor’s screen size.  
6 Set capture start time in second unit.  
This is effective in the communication mode only. It sets up the time period from executing  
the command "Capture transfer" to capturing and transferring the actual screen image. 0 to 60  
seconds can be set.  
7 Click ok button to close the setting window.  
about image Quality  
Quality : Quality mode of the captured image shows following JPEG compression mode.;  
High  
Medium : JPEG medium compression mode  
Low : JPEG high compression mode  
: JPEG low compression mode  
ꢄ7  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 5 Network Capture  
using the real time Capture  
This is a function to display the screen image of the computer by the monitor in real time.  
The captured image displayed by the monitor can be selected from the computer, web  
browser and the monitor respectively.  
registering the computers  
Up to 30 computers can be registered.  
1 Access to the control page of the monitor by using the  
web browser. From the Network menu, click Capture  
p.37).  
2 tSawbittcohditsoplCayonthneescettitoinngspeatgtein(g page by clicking the  
page number tab [3]. Enter the IP address of the com-  
puter to the PC number, and then click set button. Click  
set button to register the IP address for each page.  
The registered computer enables to start capturing if only the Network Capture icon appears on  
the task bar.  
The transfer speed of the captured image using the Real Time Capture function is depending on  
the network environment and data volume of the image. For example, when transferring an image  
(Computer resolutions and colors: XGA, full color, Picture quality: High), the transfer speed is about  
2 pages per second in maximum. It cannot be supported for movie pictures.  
The mouse pointer on the computer's screen cannot be captured.  
ꢄꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Using the Real Time Capture  
[1] Control by the computer  
* PC provides the Network Capture.  
Project this screen  
MONITOR 2  
MONITOR 1  
PC1  
imagewith MONITOR 2.  
Capture  
PC3  
PC4  
PC6  
* Start capturing from  
the PC1.  
PC5  
Select input mode to "Network" previously.  
1 Click Network Capture 3 icon on the task bar.  
2 Click start real time capture on the popup menu.  
The screen image of the computer will appear on the  
monitor display in real time.  
• To stop capturing, click stop real time capture on  
the popup menu. The captured image of the com-  
puter on the screen is frozen.  
icon on the task bar  
• To restart capturing, click restart real time capture  
on the popup menu.  
3 To end capturing, click end real time capture on the  
popup menu.  
standby  
Capturing  
If the Network PIN code set on the monitor differs  
from PIN code set on the parameter setting up,  
The Pin code setting window appears. Enter a cor-  
rect PIN code and click ok button.  
If the error message appears, check item "Parameter set up" ( p.67).  
ꢄꢆ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 5 Network Capture  
[2] Control by the web browser  
* PC provides the Network Capture.  
MONITOR 2  
MONITOR 1  
PC1  
PC2  
Capture  
* Start capturing of  
the PC1 from the  
PC5.  
PC3  
PC4  
PC6  
PC5  
Project a screen  
image of PC1 with  
PC2.  
Select input mode to "Network" previously.  
1 Access to the control page of the monitor by using the  
web browser. From the Network menu, click Capture  
2 tSaebletoctdtishpelacyothmepsuettteinr gnupamgbee(r from the pull-down  
p.37).  
menu button of "Connecting PC" and click start but-  
ton. The screen image of the selected computer will  
appear on the monitor display in real time.  
• To stop capturing, click stop button. The captured  
image of the computer on the monitor is frozen.  
3 ToToernedstcaarpt tcuarpintugr,inclgic,kcleicnkdrbeustttaornt.button.  
Set "On" when  
using the wireless  
mouse function  
The IP address of the connecting PC should be registered previously ( p.68).  
If the error message appears, check item "Parameter set up" ( p.67).  
You can use the capture function by using the web browser or the monitor if the Network  
Capture 3 software is installed into the computer correctly and its icon stays on the task bar.  
70  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Using the Network Communication  
using the Network Communication  
This Network Communication is to communicate by sharing the captured image of a com-  
puter with multiple computers and a monitor. User can draw the text and figure on the  
captured image by using a drawing tool.  
The data that has the captured image of a Main PC and communication information is sent  
to the monitor. The monitor displays this data onto the screen and serves this data to other  
computers (Sub PC) at the same time. The Sub PC receives served capture data and dis-  
plays it on the screen. The Main PC and Sub PC also can edit the captured image by using  
the drawing tool. This edited image is applied to all the computers automatically.  
MONITOR 1  
Capture  
PC6  
PC1  
PC2  
PC5  
Capture a screen  
image of PC5 and  
make marking with a  
tool.  
* The Main PC is a computer which started using of communication function, and serves  
own computer screen captured image to the Sub PC. The Main PC has an authority to  
quit using whole of communication. To become the Main PC, execute the command  
"Start Communication" or "Capture transfer". For further information, see item "How to  
use the Network Communication". ( p.75)  
* The Sub PC is a computer which receives a captured image from the Main PC. On the  
communication mode, the Sub PC can become the Main PC anytime.  
71  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 5 Network Capture  
settings before using the Network Communication  
To use the Network Communication, the capture setting of the network should be set  
either [1] or [2] described below.  
[1] setting the network unit searches all the available target computers in the net-  
work automatically.  
or  
[2] setting the target computers are registered to the network unit.  
Perform capture setting following to the description below.  
[1] When serving the capture data to all the tar-  
get computers in the network.  
By using the web browser, display "Communication set-  
ting" from menu "Network"-"Capture"-"Page 2". Confirm  
that the item Auto search target PC is "ON". If "OFF",  
change mode to "ON".  
* Network unit can find up to 30 computers in the network.  
[2] When serving the capture data to the specific  
target computers in the network.  
Set item Auto search target PC is "OFF" described in  
the above and then display "Connection setting" from  
menu "Network"-"Capture"-"Page 3" with the web  
browser. Enter the IP address of target computer and  
click set button to register.  
* Up to 30 computers can be registered to the network unit.  
To display the served capture data, the computer needs to operate the software Network Capture 3.  
7ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Using the Network Communication  
Description of capture editing window  
Select menu "Start Communication" from the popup menu appearing by clicking the  
Network Capture 3 icon on the task bar. The capture editing window will appear on the  
computer screen as the below. For basic operation of each menu, refer to the item "Menu  
tree" below.  
Menu  
Tool bar  
Capture Image  
Authority status  
indication frame  
(
.p75)  
Menu tree  
Menu  
submenu  
operation  
File  
Save Communication  
Saves a captured editing image as the data(JPEG)  
Save dialog window appears  
Quit the communication mode  
Close the Editing window  
* main pc only  
End Communication  
* sub pc only  
End Editing  
Control  
Capture transfer  
Authority  
Captures a screen image and sends it to the network unit  
Acquire/release the authority to edit the capture image  
Selects a pencil tool  
edit  
Tool  
Pencil  
Eraser  
Selects an eraser tool  
Letter frame  
Free  
Straight line  
Square  
Selects a letter frame tool  
Draws line with freehand  
Draws straight line  
Draws square  
Form  
(Shape)  
Oval  
Draws oval  
Square(Painting out) Draws filled square  
Oval(Painting out) Draws filled oval  
Attribute  
Delete all  
Undo  
Appears a attribute window  
Delete all the drawings on the image  
Cancel the last executed operation  
Display  
Help  
Full screen  
Tool bar  
Switches capture editing window, normal or full screen  
Switches standard tool buttons on or off  
Switches form(Shape) tool buttons on or off  
Switches color tool buttons on r off  
Switches attribute tool buttons on or off  
Keeps capture editing window on foreground always  
Displays software version number  
Standard  
Form(shape)  
Color  
Attribute  
Display on foreground  
Version information  
7ꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 5 Network Capture  
tool bar button names  
The following commands are assigned to the tool bar buttons. For each operation, refer to  
the description of item "Menu tree".  
Command tool  
Bar of Main PC communication  
Save  
End communication  
Capture  
transfer  
Authority  
Attribute  
standard  
tool bar  
Form  
tool bar  
Oval(Painting out)  
Square(Painting out)  
Pencil  
Letter  
frame  
Straight line  
Eraser  
Free  
Oval  
Square  
Command tool  
Bar of sub PC  
End Editing  
Color pallet 16 colors  
Color tool  
bar  
attribute  
tool bar  
Width (Large,  
Medium, Small)  
Translucence  
To switch the tool bars displaying on or off, select each command from menu "Display"-"Tool bar".  
User can realign and join the tool bars (Standard, Shape, Color, Attribute), and change it to the  
floating pallet by taking a drag and drop of the tool bars.  
There are some disable buttons depending on the tools and authority mode. In this case the but-  
ton indicates with gray.  
7ꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
How to use the Network Communication  
How to use the Network Communication  
start the communication  
1 Display an image on the computer screen.  
2 Select start Communication from the popup menu appeared  
by clicking Network Capture 3 icon on the task bar.  
The capture editing window with a captured image appears  
on the computer screen.  
If an error message appears, check item "Parameter set up". ( p.67)  
icon on the task bar  
The icon on the task bar is activated during the network communica-  
tion operates.  
standby Communication  
Join the communication (only for Sub PC)  
1 Network Capture 3 icon is activated to inform users in the net-  
work that the Network Communication is operating. Display  
2 Stheelepcot psutaprmt eedniutibnygcmlicekninug. its icon.  
The capture editing window with  
a captured image appears on the computer screen.  
exit from the communication (only for Sub PC)  
Click "  
:End editing" button on the standard tool bar. The capture editing window will be  
closed.  
This command is available with the Sub PC only.  
When executing "End editing" with the authority provided, the authority will be released.  
end the communication  
Click " :End communication" button on the standard tool bar.  
The capture editing window will be closed.  
This command is available with the Main PC only.  
It cannot be ended the communication while other PC has the authority. To end communica-  
tion forcibly, click the Capture 3 icon on the task bar and select "Shut down" on the popup  
menu.  
acquire and release of editing authority  
To edit the capture image, each computer needs to acquire the authority respectively. To  
acquire the authority, click " : Authority" button on the standard tool bar and then edit  
the capture image. The capture editing window indicates the authority status by changing  
the frame color according to the current authority mode as follows.  
Red  
Blue  
ready to acquire an authority  
Green  
other computer having  
an authority  
having an authority  
7ꢃ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 5 Network Capture  
edit capture image  
Drawing figures  
1 Click " :Pencil" button on the form tool bar.  
2 Select its attribute (shape, width, color and translucence) from the form and attribute  
3 tDoroalgbaarm. ouse pointer on the screen image to draw the figure.  
Erase drawn object  
1 Click " :Eraser" button on the form tool bar.  
2 Select its attribute (shape, width) from the form and attribute tool bar.  
3 Drag a mouse pointer on the screen image to erase the figure.  
Hints of the drawing  
Straight line tool............ To draw the vertical line or horizontal line, drag a mouse pointer with shift  
key pressed.  
Square tool........................ To draw the quadrate rectangle, drag a mouse pointer with shift key  
pressed.  
Oval tool............................. To draw the perfect circle, drag a mouse pointer with shift key pressed.  
To cancel the drawing, select command "Edit"-"Undo" from the menu.  
To erase all the drawing at once, select command "Edit"-"Delete all" from the menu.  
The popup menu appeared by right clicking of the mouse is also available to select the tool and  
change the attribute.  
Setting of the drawing tool attribute  
When clicking " :Attribute" button on the standard tool bar, the following window will  
appear. This window appears only if the pencil or eraser tool is selected.  
Line width  
Large: 8 dots  
Medium: 4 dots  
Small: 2 dots  
Select a color on the  
color pallet appeared  
by clicking here.  
Sets translucent  
color  
7ꢄ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
How to use the Network Communication  
Drawing letter  
1 Click " :Letter frame" button on the form  
2 tSoeolelcbtaar.color of text with color tool bar.  
3 Drag a mouse pointer on the screen image to  
specify the area of the letter frame. The letter  
4 Einnpteurt tdhiaelolegttwerinodnotowthweillwaipnpdeoawr..  
To change the letter attribute, click Letter  
attribute button. See item "letter attribute  
5 sCeltitcinkgo" bkeblouwt.ton to fix the content. The  
entered letter appears on the captured image.  
If the entered letter overflows the area of letter frame, the letter frame is automatically extended  
downward.  
Up to 1000 characters can be used for a letter frame.  
Letter attribute setting  
The font attribute setting window appears when clicking " :Attribute" button on the  
standard tool bar with the letter frame tool selected, or clicking Letter attribute button  
on the letter input dialog window described the above.  
Sets type face, style, size and  
effects of the font  
Predefined 16 col-  
ors are available.  
Sets translucent  
color  
77  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 5 Network Capture  
Network Communication operation and change of state  
Network Communication can be used under the environment which one or more com-  
puters are connected to the monitor via the network.  
Preparation  
Launch the Network Capture 3 software on the target computer ( p.66). Set the monitor  
in the standby or turning on. Check IP address of the target computer is registered in the  
connection list ( p.72).  
Operation on the Main PC  
Operation on the Sub PC  
The icon on the task bar is activated to  
let users know that the captured image is  
now serving.  
1 Executing the command "Start Editing".  
The capture image on the Main PC  
appears on the screen.  
Frame  
Frame  
1
Executing the command "Start Communication".  
The capture editing window appears on the  
screen. The icon on the task bar is activated.  
r
B
2
Editing the capture image using with the tools.  
The editing information on the Main PC is  
The editing information is automatically  
r
G
B
B
G
r
reflected on the Sub PC.  
transferred to the Sub PC.  
The color of authority status frame chang-  
es green.  
3 Releasing the editing authority.  
The color of authority status frame changes green.  
2 Acquiring the authority.  
The color of authority status frame chang-  
es red.  
The color of authority status frame changes blue.  
3 Editing the captured image using with the  
The editing information on the Sub PC is  
reflected on the Main PC.  
tools.  
B
r
The editing information is automatically  
transferred to the target PC.  
4 Releasing the editing authority.  
The color of authority status frame chang-  
es green.  
The color of authority status frame changes green.  
G
G
B
The color of authority status frame chang-  
es blue.  
4 Acquiring the authority.  
r
The color of authority status frame changes red.  
5 Repeat steps 2, 3 if required.  
5 Repeat steps 2 to 4 if required.  
6
Executing the command "Capture transfer".  
A new captured screen image appears on  
Updating the editing window with a new  
r
r
B
the editing window.  
captured screen image.  
7 Repeat steps 2 to 5.  
8 Ending the communication.  
The capture editing window disappears.  
The capture editing window disappears.  
The monitor displays the edited captured image on the screen when the input mode of the moni-  
tor is set "Network".  
The command "Save Communication" can be executed in any of the mode even if not having the  
authority.  
The arrow () shows a response to the command executed.  
The execution of the command "End Communication" or "End Editing" on the Sub PC has no  
effect on the other target computers.  
7ꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Executing the forcing mode  
executing the forcing mode  
The network capture setting of the web page provides a forcing executing command. This  
command executes the release of authority or ending the communication forcibly. This is  
useful when the other target PC keeps an authority all the time, or when the condition of  
the communication is not stable.  
Click page 2 Communication setting from the menu "Network"-"Capture". Execute com-  
mand by clicking the button Free, Quit or update.  
Displays IP address of the Main PC  
Displays IP address of the computer  
has a editing authority  
item  
Free...........................Releases the editing authority forcibly  
Sets condition which all the users can acquire an authority  
Quit...........................Quits the communication forcibly  
The capture editing window on all the computers closes forcibly.  
Update....................Acquires the latest communication status  
Updates the IP address of the Main PC and Update authorized PC.  
Description  
7ꢆ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 5 Network Capture  
Network capture function is for projector originally. So some error  
messages include word "PJ". Here "PJ" means "Monitor".  
error information  
error messages  
Cause and corresponding  
Error when executing the communication. The parameter setting  
(host name, capture port) has not been set.  
Check parameter setting ( p.67)  
Set up the parameter.  
Error when executing Start Communication or Start real time cap-  
ture. The IP address of the computer has not been registered.  
Register the IP address by using the web browser ( p.72)  
It has not been registered to  
monitor as a group.  
Error when executing Start Communication or Start real time cap-  
ture. The other capture, viewer or advanced card imager function  
is now operating.  
Cannot be displayed as moni-  
tor is under display.  
Wait until the communication function is available.  
Cannot establish the connection with the network unit when  
executing the Start communication, End communication, Capture  
transfer, Start real time capture or End real time capture.  
Cannot connect to monitor.  
Check connection of the network cable.  
Cannot transfer the data to the network unit when executing the  
Start Communication, End Communication, Capture transfer, Start  
real time capture or End real time capture. The time out period is  
10 seconds.  
Cannot transfer data to moni-  
tor.  
Check connection of the network cable.  
Cannot receive the data from the network unit when executing  
the Start Communication, End Communication, Capture transfer,  
Start real time capture or End real time capture. The time out  
period is 10 seconds.  
Cannot receive data from mon-  
itor.  
Check connection of the network cable.  
Other PC has authority.  
Cannot complete "Network  
Communication".  
When executing the End communication, you cannot quit the  
communication because other computer has an authority  
Other PC has authority. Cannot  
obtain authority.  
Other computer has an authority.  
When setting the parameter, the computer cannot find the set-  
ting host name or IP address in the network.  
Use available host name or IP address.  
The server name or address  
could nt be resolved.  
When setting the parameter, the reserved port number is speci-  
fied.  
Check parameter setting ( p.67)  
Invalid port number  
Monitor has not started Network  
Communication. Close the window  
and open it again.  
The monitor might have turned off during the communication.  
Check monitor power and restart executing "Start communication".  
ꢅ0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 6  
6
Network Viewer  
Network Viewer is a function to display the image data stored in  
the file servers by the monitor through the network.  
Describes about file converter software File Converter 1, File  
Converter 2 and program creator software Program Editor, and  
how to use Network Viewer.  
81  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 6 Network Viewer  
Creating the available data [Network Viewer 3]  
The image available with this monitor is the JPEG format (.jpg). There are several types of  
JPEG data. Before using the images with the Network Viewer function, it should be con-  
verted to the optimized JPEG data for this monitor.  
[1] How to use the Network Viewer 3 (File Converter 1)  
The File Converter 1 is a software to convert from the JPEG, bitmap or Power Point data to  
the optimized JPEG data for the monitor.  
Launch and quit the File  
Converter 1  
To launch the File Converter 1, click  
"Network Viewer 3 (File Converter 1)"  
menu from "Start" - "All Programs" -  
"Network Viewer & Capture 3" menu.  
To quit the File Converter 1, click  
on the close box on the upper  
right hand of the window.  
File Converter 1 window  
Menu  
Command  
Tool Button  
Preview window  
Explorer window  
to browse image  
files  
ꢅꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Creating the available data [Network Viewer 3]  
Menu tree  
Menu  
sub Menu  
Description  
View  
Update  
Preview size  
Option  
Convert a folder  
Convert each file  
Version information  
Updates contents of the preview window  
Sets size of the preview image, Large, Middle, Small  
Sets default of the output destination and conversion mode  
Converts files in a folder into JPEG files at once.  
Converts a file into a JPEG file individually  
tools  
Conversion  
Help  
Displays the version information  
Command tool Button  
Convert  
each file  
Convert a  
folder  
Update  
Create the available data  
1 Select a folder in which the image files are stored by the explorer window.  
The preview images of the available image data (JPEG file, Bitmap file, power point file)  
in the selected folder are displayed on the preview window.  
On the preview window, the preview displayed with the red frame represents a file not opti-  
mized JPEG file or Bitmap file for the display. The preview without the red frame represents  
the optimized JPEG file for the display. So you do not need to convert them again, but if you  
change the size or image quality, perform to convert them again.  
Preview with red frame  
represents the file not  
optimized for the dis-  
play.  
Preview of the Power  
Point data  
ꢅꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6 Network Viewer  
2 When converting each file, select a preview  
image first and then click Convert each file.  
To select two or more files at once, press and hold  
"Shift" key or "Ctrl" key and then click the preview images.  
When converting all the files in a folder, select a folder and click Convert a folder.  
3 As the confirmation window appears, check the conversion object and conversion  
type and then click ok button. The File converter 1 starts converting and stores the  
optimized files into the output folder. It enables you to select a local hard disk of your  
computer, shared computer in the network, a directory of the FTP server. To change the  
conversion type or output destination, click Change button.  
If the power point file is included in the conversion object, the Microsoft Power Point software  
will be launched and start converting automatically.  
Dialog window when using "Convert  
each file" and "Convert a folder"  
To convert images from the power point file, Microsoft Power Point software is required in your  
computer.  
In the power point file conversion, all the pages are converted into JPEG files separately.  
ꢅꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Creating the available data [Network Viewer 3]  
setting of output destination and conversion mode  
When clicking Change button on the confirma-  
tion window in the step 3 on the previous page,  
following option setting window appears.  
output destination  
Select either Folder or FtP server as the output  
destination of the converted files.  
Folder  
Output folder.....Specify a folder in the local hard disk  
or shared computer in the network  
FTP server  
Host name............Enter host name or IP address of the  
FTP server  
Root Folder..........Specify the root directory of the FTP  
server. Normally use "/".  
User ID ....................Enter your login account of the FTP  
sever.  
Password...............Enter your password of the FTP server.  
Output folder.....Specify a directory of the FTP server.  
Conversion mode  
Resolution............Selects output image resolution (VGA to SXGA+)  
The image resolution higher than the monitor's panel resolution cannot be dis-  
played.  
Image rotation.....Selects image rotation (0, 90, 180, 270).  
Conversion Type  
Fit............................. Converts as either width or height of  
the image sets to be the maximum  
screen width or height.  
Justify  
[both ends]............... Converts as width of the image sets  
to be the maximum screen width.  
Justify  
[top and bottom]..... Converts as height of the image sets  
to be the maximum screen height.  
Cut........................... Cuts image with the screen size not depending on the image size. This type has fol-  
lowing mode.  
Select this mode when you want to have the images with the original size. Select  
each mode by clicking on the button.  
Image Quality....Selects an image conversion quality with "High", "Mid" or "Low".  
ꢅꢃ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6 Network Viewer  
[2] How to use the Network Viewer 3 (File Converter 2)  
The File Converter 2 is a kind of the printer driver software to convert to the optimized  
JPEG data for the display from the any documents created by the other software such as  
text editor, spreadsheet or presentation software. It is possible to convert to the JPEG file  
from the any kinds of documents created by the software which has a "print" menu.  
Create the available data  
1 Open a document with the individual software.  
2 Select a "Print" sub menu and open the printing dialog. On the window, select "Network  
Viewer 3 (File Converter 2)" icon on "Select Printer" item and click Print button.  
Set the option setting for the page layout  
or paper setting by clicking Preferences  
button if required.  
3 Select a folder and click save button.  
The file name is named with "Image001" as  
the default. If the converted image has 2 or  
more pages, the file names are numbered  
from "001" to "999" in a sequential order.  
Image quality and Conversion type can be  
setup on this window. For further informa-  
tion, please see "Setting of the Conversion  
Mode" ( p.85).  
I
t may appear the white space around the  
edges on the converted image depending  
on the type of the image data.  
The above procedure may differ from each computer environment and applications.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ꢅꢄ  
 
Creating a program file [Program Editor]  
Creating a program file [Program editor]  
Network Viewer 3 (Program Editor) is a tool to make a program file which specifies the dis-  
play order of the image and its file path in the file server (FTP server). The Program Editor  
makes a folder "DispParam" at the login root directory in the FTP server and makes files as  
each program name into this folder. These files are called "Program". By specifying the pro-  
gram file with the Network Viewer function, you can have the programmed display with  
the monitor .  
Procedure of making program  
1 To launch the Program Editor, click "Network Viewer 3  
(Program Editor)" menu from "Start" - "All Programs" -  
"Network Viewer & Capture 3" menu.  
2Click Connect button.  
3If the connection setting window appears, enter the each  
item and then click ok button.  
The setting window disappears and then the programs  
are listed on the window if there are program files at  
the login directory in the connected FTP server.  
item  
Description  
Host name............Enter the FTP server name or IP address  
Root Folder .................Specify the root directory of the FTP server. Normally use "/".  
User ID ....................Enter your login account of the FTP sever or use blank when you login as anonymous  
account for the FTP server  
Password...............Enter your password (PIN code) or use blank when you login as anonymous account.  
iMPortaNt  
it is required to set the write permission mode for the login directory of the FtP server.  
if only the read only mode, you will have an error when you register a new program.  
ꢅ7  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 6 Network Viewer  
4 Click New button.  
5 Enter a program name and click add button.  
Change : Changes the contents of  
the program file.  
Remove : Removes the program from  
6 The folder selection window appears and select a  
folder in which the JPEG data are stored and then  
click add button to register into the folder lists.  
the list.  
Add....................Displays the folder selection window.  
Delete..............Deletes the folder path from the folder list.  
UP.......................Moves up the selected folder path.  
DOWN .............Moves down the selected folder path.  
Edit.....................Used to set up the display order or display time of the image individually. For further  
information see item "Setting up the display order and time of the images" on the  
next page.  
The order of the display is listed in the folder list window. To change the order of the display,  
change the list order of the folder list by using uP or DowN button.  
The programs are stored into the "DispParam" folder at the login root directory and this  
"DispParam" folder is made by software automatically.  
7 Click register button to register the folder list into the program.  
8 Click Close button to quit the Program Editor.  
ꢅꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Creating a program file [Program Editor]  
setting up the display order and time of the images  
In the default setting, the display order of the images is ASCII code order of the file name.  
To change the display order or to set up the display time, take the following procedure.  
Display the folder list window in step 6 of the previous page.  
1 Select a folder list contains images to change.  
2 Click edit button. The images in the selected folder are displayed with the file name on  
the index window.  
When selecting "Image" from "View" menu,  
the thumbnail of the image will be displayed  
(default setting). When selecting "Icon", the  
icon image will be displayed.  
It takes a time to display thumbnails.  
The number in front of the file name indicates  
the display order of the image.  
Display order  
number  
File name  
Menu  
sub menu  
Description  
File  
Edit  
Exit................................Closes index window  
UP..................................Steps up the display order of the selected images  
DOWN........................Steps down the display order of the selected images  
Display time...........Sets up the display time of the selected images  
Image.........................Displays thumbnail of the images  
View  
Icon..............................Displays images as the fixed icons  
Update.......................Updates images information on the index window  
ꢅꢆ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 6 Network Viewer  
1
3 To change the display order, select* files and then click uP or DowN button on the  
menu bar to move them onto your desired place, or select files and then drag and drop  
them onto your desired place with mouse.  
2
1
4 To change the display time* , select* files and  
then click Display time button on the menu  
bar to display the Display time setting window.  
Check "Display time" check box and set display  
time. To cancel the display time, un-check the  
"Display time" check box.  
image frame on the index window  
Image frame on the index window has 3 kinds of display modes as follows.  
No frame  
Blue frame  
Red frame  
: Shows that the image in the folder is unchanged  
: Shows that image is added into the folder newly  
: Shows that image is deleted from the folder  
Added  
Moved  
*1 Enable to select multiple files at once by using "Shift" or "Control" key, or with mouse cursor.  
*2 Enable to set up 3 to 240 seconds for display time.  
ꢆ0  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Creating a program file [Program Editor]  
example of the created program selection  
Use the web browser to access to the control page of the monitor. Click Viewer of the  
Network menu on the web page, then connect to the FTP server and select the program  
name which was made at previous section. The monitor starts displaying the images  
along the program. For further information, please see "Using the Network Viewer func-  
tion" ( p.92).  
This function is not available in the light mode.  
The limitation of the Program file  
There are several limitations for the program file as follows;  
* Number of programs in a root folder is less than 1000.  
* Number of folders in a program is less than 100.  
* Total characters of folder name is less than 255.  
* Total characters of program file name is less than 63.  
* Do not make a program name started with ".".  
* Do not make a program name contained with following characters:  
\ / : , ; * ? " < > |  
* The program name started with " "(space) is registered with removing the space.  
ꢆ1  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6 Network Viewer  
using the Network Viewer function  
The Network Viewer is a function to acquire the JPEG image data from the file servers  
placed in the network and display them on the monitor. The displayed image data are  
specified with the folder unit. You can set the display period and repeating times, and also  
you can register those folders as the program. *the network viewer function cannot be  
used when using the network capture function.  
Condition to use the Network Viewer function:  
* Enables to use the FTP service with Windows 2000 Professional or XP Professional.  
* User must have a full-access account to the FTP server or the FTP server allows anyone to  
use with "Anonymous" account which also has a full-access mode.  
* The allowed number of simultaneous access from the same IP address is more than 20.  
To use this function, it is necessary to disable "pop-up block" function of the web  
browser.  
Control by the web browser  
MONITOR 2  
MONITOR 1  
PC1  
PC2  
JPEG  
PC3  
PC4  
PC6  
PC5  
Project JPEG  
images stored in  
PC3 with PC2  
Prog.  
JPEG  
FTP file server  
Select input mode to "Network" previously.  
1 Access to the control page on the monitor by using the web browser.  
From the main menu, click Network - Viewer to display the setting page.  
ꢆꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Using the network viewer function  
2 Setup the setting page [1] of Image display setting.  
item  
Description  
Host name............Enter the host name or IP address of FTP server,  
yourftp.server etc.  
Folder Path ..........Use "/"(root directory) in normal, or enter the  
directory name follow the "/" as shown in the  
below example if you have a specified direc-  
tory in the server.  
/data/  
1
User ID* .................Enter your login account of the FTP server  
Password* ...........Enter your password of the FTP server  
1
1
Option* .................Set "Display ON" when you display the  
acquired preview images on the web browser.  
3 Setup the setting page [2] of Selection display setting.  
Click select after selecting from the pull-down menu "Folder Selection" or "Program  
Selection" for the Display object. The list window appears and select a program or folder  
and then click set on the window.  
Displays the  
path of the file or  
folder selected  
Selects the display type either the listed  
with file name or listed with thumbnail.  
The thumbnail can be selected "4 divi-  
sion", "6 division" or "9 division".  
This function is not available in the light mode.  
See item "Creating a Program file [Program Editor]"( p.87) for about program.  
*1 iMPortaNt NotiCe  
Please note that if you use the FtP server with personal account except anonymous  
account, the user iD and password may be displayed on the browser depending on  
the version of the browser. we recommend that this function should be used with the  
anonymous account usually.  
ꢆꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6 Network Viewer  
When clicking set, the file list or preview list of the selected folder or program is dis-  
played on the window.  
Decides a image to  
start auto display with  
Selects a page  
The original image is displayed on  
another window by clicking on  
the preview image or file name  
Button  
operation  
<<...............................Steps down the startup image in  
the auto display function  
>>...............................Steps up the startup image in the  
auto display function  
List.............................Switches to the List mode  
Thumbnail............Switches to the thumbnail mode  
Close.........................Close the window  
This function is not available in the light mode.  
The preview image will not appear when the option is set "Display OFF".( p.93)  
Up to 1000 images can be displayed.  
When selecting "folder selection", it displays images placed at the first directory in the selected folder.  
The display order of the images is according to the ASCII character order when selecting "folder  
selection", or is specified by the Program Editor when selecting "program selection".  
ꢆꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Using the network viewer function  
4 Auto Display setting and control page [3]  
Repeat times  
(0 to 255 times)  
* 0 means endless play  
1
Display period* of the  
image (3 to 240 sec.)  
Click here to check the  
further information of  
the file error  
The preview image will not  
appear when the option is  
set "Display OFF".( p.93)  
Error info.  
1. Click start button to start the auto-display. The image in the selected folder or pro-  
gram is displayed on the monitor's screen. The web browser opens another window  
and displays the preview images on the Auto Control window sequentially.  
2. Click stop button to stop the auto-display.  
• Restart the auto-display, click restart button.  
* During the auto-display stops, it enables you to display the images manually by using [<<] or  
[>>] button.  
3. Click end button to end the auto-display.  
• When pressing the error button, the further information of the file error is displayed.  
For further error information, refer to the next page.  
*1 When selecting the program file for auto-display, the display time of each image gives preference  
to the setting specified by the program file over the setting specified by the auto-display function  
above. The images not set the display time is according to the display time specified by the auto-  
display function above.  
The display period is greatly affected by the network environment or the operation of multi con-  
trol, so it may not display the image as the specified display period.  
The switching is not the same timing between the images on the screen and on the web browser.  
ꢆꢃ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 6 Network Viewer  
Error information  
Description  
error type  
File Error  
It is displayed when the network unit cannot acquire the correct file imag-  
es from the FTP server, or when the master monitor is turned off during the  
multi-control.  
Click error button to check the details.  
Connection Error  
It may be displayed when the slave monitor is using the Network Viewer  
or Capture function during the multi-control. Check which monitor has an  
error , see item "Multi Control/Check & Change" ( p.61-62).  
When the file error is occurred during the auto-display, you may have the alert e-mail message.  
For further information, please see item "3 Option selection for sending alert mail" ( p.39).  
ꢆꢄ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Chapter ꢀ Appendix  
Connection examples  
Web browser setting  
Technical data  
Q & A  
9ꢀ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 7 Appendix  
examples of connection  
Peer-To-Peer connection  
Connecting the monitor (LCD01) to the control computer (PC05) directly.  
* UTP cross cable  
Computer Name: PC05  
Monitor Name: LCD01  
IP Address  
Subnet Mask  
Default Gateway  
DNS  
: 192.168.0.5  
IP Address  
: 192.168.0.2  
: 255.255.255.0  
: 255.255.255.0  
Subnet Mask  
:
:
Default Gateway : 0.0.0.0  
DNS  
: 0.0.0.0  
Connecting the monitor (LCD01) to the control computer (PC05) via the hub.  
Hub  
To another network  
Computer Name: PC05  
IP Address  
Subnet Mask  
Default Gateway  
DNS  
: 192.168.0.5  
Monitor Name: LCD01  
: 255.255.255.0  
IP Address  
: 192.168.0.2  
: 255.255.255.0  
:
:
Subnet Mask  
Default Gateway : 0.0.0.0  
DNS  
: 0.0.0.0  
Computer Name: PC10  
IP Address  
Subnet Mask  
Default Gateway  
DNS  
: 192.168.0.10  
: 255.255.255.0  
:
:
When the monitor is connected to the computer directly without hub, the UTP cross cable should  
be used.  
ꢆꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Examples of connection  
The gateway (Router) installed in the network  
Connecting the monitor (LCD01) to the control computer (PC05) via the gateway.  
Entrance hall  
Computer Name : PC205  
IP Address  
: 192.168.200.5  
: 255.255.255.0  
Subnet Mask  
Default Gateway : 192.168.200.1  
DNS  
: 192.168.201.1  
Monitor Name: LCD01  
IP Address  
: 192.168.200.15  
: 255.255.255.0  
Subnet Mask  
Default Gateway : 192.168.200.1  
DNS  
: 192.168.201.1  
Hub  
Network Group: 192.168.200.x  
To another network  
IP Address : 192.168.200.1  
Gateway (Router)  
IP Address : 192.168.100.1  
IP Address : 192.168.10.1  
Office  
Hub  
Hub  
Computer Name: PC05  
Computer Name : PC10  
Computer Name : PC51  
Computer Name : PC61  
IP Address  
: 192.168.10.10  
: 255.255.255.0  
IP Address  
: 192.168.10.51  
: 255.255.255.0  
IP Address  
: 192.168.10.61  
: 255.255.255.0  
IP Address  
: 192.168.10.5  
Subnet Mask  
Subnet Mask  
Subnet Mask  
Subnet Mask  
: 255.255.255.0  
Default Gateway : 192.168.10.1  
Default Gateway : 192.168.10.1  
Default Gateway : 192.168.10.1  
Default Gateway : 192.168.10.1  
DNS  
: 192.168.201.1  
DNS  
: 192.168.201.1  
DNS  
: 192.168.201.1  
DNS  
: 192.168.201.1  
Network Group: 192.168.10.x  
ꢆꢆ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 7 Appendix  
web browser setting  
This product is designed to enable the monitor to be set up and controlled from an  
Internet web browser. Depending on the preference settings of the web browser, some  
control functions may not be available. Please make sure that the following functions are  
set up properly in the web browser.  
active script/Javascript enable  
There are some control items used with  
the JavaScript function in the setting  
pages. If the web browser is set not to use  
this JavaScript function, it may not control  
the monitor properly. In this case, the fol-  
lowing warning message will be displayed  
on the top of the page. To enable the  
JavaScript, please see further instructions  
on the next page.  
Flash Player enable  
The setting page of this product contains  
the Flash contents. To display the setting  
page, the Adobe Flash Player version 6  
or later is required to be installed on your  
computer. For further product informa-  
tion, see the Adobe homepage. (http://  
www.adobe.com). Even if your computer  
provides the Adobe Flash Player and the  
setting page does not appear on the web  
browser, check that Flash Player Plug-  
In(Shockwave Flash) is installed and set up correctly. please see further instructions on the  
next page and it is depending on the web browser.  
Proxy setting  
In some cases, your web browser is set up to use the proxy server for the internet or  
intranet connection. In this case, when you install this product into the local network, you  
should set up the proxy setting of web browser preference correctly. Especially when con-  
necting the monitor and computer with a UTP cross cable directly, or when the network  
does not provide the proxy server, make sure that "not use proxy server" is set up in your  
web browser preference. Please see item "Examples: OS/Browsers" in the next page for  
further setting up procedure.  
There are various ways to change your browser preferences depending on the version or applica-  
tions. Please see the setting instructions on next page for example and also refer to on-line help  
of your web browser.  
100  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Web browser setting  
examples: os/Browsers  
windows XP Professional  
Internet Explorer v.6.0  
activescript setting  
Select internet options from tools menu on the web browser and then select security  
tab and click Customize Level… button. On the security setting window, scroll down and  
find the scripting item, make sure that "Enable" is selected in item active scripting.  
Flash Player enable  
activeX controls and plug-ins setting  
Select internet options from tools menu  
on the web browser and then select security  
tab and click Customize Level… button. On  
the security setting window, scroll down and  
find the activeX controls and Plug-ins item,  
make sure that "Enable" is selected in item run  
activeX controls and plug-ins.  
101  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 7 Appendix  
Flash Player add-on setting  
Select Manage add-ons... from tools  
menu on the web browser. Select "Add-ons  
currently located in Internet Explorer" from  
show pull-down menu. Make sure that the  
"Shockwave Flash Object" is listed under the  
item "Enabled".  
Proxy setting  
Select internet options from tools  
menu on the web browser and then select  
Connection tab and click LaN settings  
button. Properly set up your web browser's the proxy server settings according to the  
local area network environment to which the monitor is connected.  
- using proxy server  
To use an external internet connection from the local area network, check the item use a  
proxy server and enter the proxy server address and port correctly in the proxy settings  
window. For further instruction please consult your network administrator.  
- Not using proxy server  
Uncheck the item use a proxy server.  
If you connect the monitor to the computer directly with UTP cross cable, this must be  
unchecked.  
To designate proxy settings that will not use the  
proxy server when accessing the monitor installed  
in the local area network, enter the IP address or  
domain name here.  
10ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Web browser setting  
Netscape Navigator v.ꢀ.0  
Javascript setting  
Select Preference from edit  
menu on the web browser  
an d th en s ele c t th e item  
advanced/scripts & Plugins  
in the Category column. Make  
sure that the enable Javascript  
for Navigator is checked.  
Flash Player enable  
Flash Player Plug-in setting  
Select about:Plug-ins from Help  
menu on the web browser. The  
plug-ins software provided on the  
browser are listed on the page.  
Check that the Flash Player Plug-  
in (shockwave Flash) is installed  
and set up correctly as the below.  
10ꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 7 Appendix  
Proxy setting  
Select Preference from edit menu on the web browser and then select the item advanced/  
Proxies in the Category column. Properly set up your web browser's the proxy server set-  
tings according to the local area network environment to which the monitor is connected.  
- using proxy server  
When you use an external internet connection from the local area network, select the item  
Manual proxy configuration. Enter the proxy server address and port number correctly on  
HttP Proxy item. For further instruction please consult your network administrator.  
- Not using proxy server  
Select the item Direct connection to the internet in the proxy setting window.  
If you connect the monitor to the computer directly with UTP cross cable, this must be  
selected.  
To designate proxy settings that will not use  
the proxy server when accessing the moni-  
tor installed in the local area network, enter  
the IP address or domain name here.  
10ꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Product specification  
Product specification  
Type.......................................................... LD-Net Organizer (network unit)  
LAN interface...................................... Applicant regulation IEEE802.3 (10Base-T)  
IEEE802.3u (100Base-TX)  
Data transfer speed  
Data transfer mode  
10Mbps/100Mbps  
Half duplex/Full Duplex  
8-pin modular (RJ-45)  
TCP/IP  
Terminal  
Network protocol.............................TCP/IP specification  
Power source...................................... Supplied from the monitor  
Power consumption...................... 3.0 watts  
Dimensions (W x H x D)............... 5.20" x 4.13x 1.32(132 x 105 x 33.6 x mm)  
Weight.................................................... 0.57 lbs (258 g)  
Built-in battery................................... Lithium battery, Type CR2032, 3.0V  
Operating temperature ............... 41˚F ~ 95 ˚F (5˚C ~ 35 ˚C)  
Storage temperature..................... 14˚F ~ 140˚F (-10˚C ~ 60˚C)  
* The specifications are subject to change without notice.  
10ꢃ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 7 Appendix  
Port specification  
LAN port specification  
8-pin modular connector (rJ-45)  
1 2 3 4 5 6 7 8  
Pin No.  
Signal  
Function  
1
2
3
4
5
6
7
8
TX+  
TX-  
Transfer data (+)  
Transfer data (-)  
Receive data (+)  
RD+  
(not used)  
(not used)  
RD-  
Receive data (-)  
(not used)  
(not used)  
10ꢄ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Q&A  
Q&a  
installation/access  
Q
A
Why doesn’t the setting page appear in my web browser?  
Following causes are possible. Please check them.  
1. The monitor does not connect to the network.  
Check LED indicators status ( p.17).  
- Check the connection of LAN cable if the LINK indicator does not illuminate  
red.  
- Check the network configuration of the monitor if ACT indicator does not  
illuminate green.  
2. Wrong network configuration of the monitor  
Check the network configuration of the monitor ( p.37).  
3. Wrong network configuration of the computer.  
Check the network configuration of the computer.  
4. The network unit is used with the default setting ( p.21).  
5. The proxy setting of the web browser is not set correctly ( p.100).  
6. The computer does not provide TCP/IP protocol.  
Q
A
No setting page in my web browser? Is the problem in the network or in  
the monitor? I would like to find out the problem whether it is in the net-  
work or in the monitor  
Check it by the following steps  
1. Disconnect the monitor from the network and connect the monitor and com-  
puter with the UTP cross cable directly.  
2. Change network configuration of the computer and monitor as shown in the  
example below.  
(Monitor setting)  
IP Address  
Subnet Mask  
Default gateway  
DNS  
(Computer setting)  
IP Address  
Subnet Mask  
Default gateway  
DNS  
: 192.168.0.2  
: 255.255.255.0  
: 0.0.0.0  
: 192.168.0.5  
: 255.255.255.0  
: (blank)  
: 0.0.0.0  
: (blank)  
107  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
Chapter 7 Appendix  
3. Enter the monitor’s IP address [192.168.0.2] at "Address" column on the Web  
browser. [Note] Make sure that the proxy setting of your web browser is set  
"Not use a proxy server" ( p.100).  
4. If the login page appears, this product is operating properly. The problems  
may be in the network configuration of the computer or in the network. Please  
try to set up the network by following item "Network configuration" ( p.21).  
If the login page does not appear, please check for proper mounting of this  
product onto the monitor by referring to chapter "Installation and Network  
configuration" ( p.18-19).  
Q
A
How can I restrict access from the computer.  
1. Please use the password authentication function on the login page ( p.30).  
2. Please use the IP filtering function provided with the gateway (router) to  
restrict the accessing from the computer. For further information please con-  
sult your network administrator.  
Q
A
Can I access the monitor installed on the company’s local area network  
from a remote location?  
There are some ways to access to the monitor in the LAN, but you must consult  
your network administrator for security reason.  
Use of modem  
(Connect to the company’s network from your home or some other places by  
using modem.)  
Use of private line  
(Connect to the company’s network from the branch office or maintenance  
office by using private line.)  
Use of internet  
(Connect to the company’s network from your home, branch office or some  
other places by using the internet.)  
Q
A
We use the DHCP/BOOTP server to assign the IP address. Is it possible to  
use the network unit in this network environment?  
Possible. As the network unit does not support the DHCP/BOOTP server, the fixed IP  
address must be configured manually. Please consult your network administrator (  
p.25).  
10ꢅ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Q&A  
Q
A
How can I install several monitors equipped with the network unit?  
Install and configure network one by one to avoid the IP address collision each  
other ( p.25).  
To configure the IP address please see item "Network configuration" ( p.21).  
Q
A
How many monitors can I control with multi-control function?  
It has been designed to control up to 100 sets but it depends on the network envi-  
ronment.  
Password/Login  
Q
A
What should I do when I forget the password?  
If you forget the Network PIN code to the monitor, you can initialize PIN code and IP  
Address/Sub net/Gateway/DNS by selecting "Network initial" from "Installation  
mode" menu on the monitor. For further information, please see instruction manual  
of the monitor.  
Q
A
Can I register the setting page as a web browser "Favorites" or  
"Bookmarks"?  
Please add "Login" page to your "Favorites" or "Bookmarks". Do not add the speci-  
fied setting page because it will not be able to perform the password authentica-  
tion correctly.  
10ꢆ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 7 Appendix  
operation  
Q
A
Why can't I change the controls in the setting page with web browser?  
Please make sure the monitor is turned on. If it is in the standby mode, the setting is  
not effective to the monitor. To control the monitor with a web browser, the moni-  
tor must be in the powered-on condition. Also, monitors registered for multi-con-  
trol cannot have any controls changed if they are in standby mode. But timer and  
clock settings are always effective, even for monitors in standby mode.  
Q
A
Why does it sometimes take a lot of time to complete the page display?  
The display speed of the page depends on the network environment in which both  
the monitor and computer are placed. It may take much time to complete the page  
display if network traffic is heavy. Please consult your network administrator. You  
can select the Light mode for displaying pages quickly ( p.30).  
Q
A
I use many of the monitors in the network. How can I use names of the  
monitors to recognize each monitor instead of IP addresses?  
You can manage the monitors with nicknames instead of the IP address. Please see  
item "Multi-control" for further information ( p.59).  
By registering the monitor name and IP address with the DNS server, it can be  
accessed with the nickname from the any computer referred to the DNS server.  
Please consult your network administrator.  
Q
A
How many numbers of the E-mail address can I register in the E-mail set-  
ting page.  
You can register up to 10 addresses.  
110  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Q&A  
Q
A
Why am I not receiving E-mail alert messages?  
Make sure that the registered E-mail address and SMTP server address are correct. If  
the SMTP server is located in your LAN (Local Area network), the address should be  
set to the SMTP server in your LAN. The SMTP server located outside of your LAN  
may not be available for security reason. For further information please contact your  
network administrator ( p.38).  
It may be required for the authentication depending on the SMTP server. This prod-  
uct does not support this kind of SMTP server.  
111  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 7 Appendix  
Q
A
Can I update the firmware of the network unit.  
It is possible to update the firmware through the network. It is required to have a  
special tool for the updating. For further information please consult your local deal-  
er. The version number of the firmware is indicated on the lower part of the "Initial  
setting" page.  
Version of the  
firmware  
11ꢀ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Q&A  
Q
A
What are the rules for IP address assignment?  
If the network is constructed with TCP/IP protocol, a unique IP address is required  
for each piece of network equipment. The following are basic rules of the assign-  
ment.  
Rule1  
Do not configure the same IP address to the network equipment in the  
same network group. Each piece of equipment must be assigned a unique IP  
address.  
If the IP address is set [192.168.x.x], the Subnet Mask should be set  
[255.255.255.0] for example.  
Rule2  
The start address [xxx.xxx.xxx.0] and the last address [xxx.xxx.xxx.255] of  
the IP address must not be assigned to any other equipment. These address  
numbers are reserved.  
Rule3  
The IP address must correlate to a network number. If network numbers are  
different between the equipment, they cannot establish communications  
each other. In this case, the router is placed in the networks to make the rout-  
ing.  
Q
A
What is the MAC address assigned to the network unit?  
The MAC address is indicated on the case back as the below.  
MAC Address  
MAC address  
11ꢁ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Chapter 7 Appendix  
Network capture  
Q
A
Why doesn’t the computer screen appear on the monitor?  
1. Make sure that the input mode of the monitor is "Network".  
2. Make sure that the Network Capture icon on the task bar of the computer is active  
(
p.66).  
3. Check the parameter set up ( p.67).  
Make sure that the numbers of the capture port is the same as the monitor’s port  
number. The default port number is 9000. If the alert message "Invalid Port No."  
appears, your computer may be using this port number already. In this case, use  
another port number.  
4. Check the IP address of the computer is registered to the network unit correctly (  
p. 68).  
5. Make sure that your computer is not using the firewall function. The network unit  
may not be able to use the port due to this firewall function. In this case, please  
turn off this function temporarily. There are also some port limitations on the net-  
work equipment such as router. Please consult your network administrator.  
Network Viewer  
Q
A
Images from the file server don’t appear on the monitor?  
1. Make sure that the input mode of the monitor is "Network".  
2. Check the account setting of the FTP server ( p.93).  
3. The files in the FTP server must be optimized JPEG and converted by using the File  
Converter 1 or 2. Please check data format. ( p.83)  
4. There are several limitations for image file name and program name. Please check  
file names and program names ( p.91).  
5. Make sure that your computer is not using the firewall function. The network unit  
may not be able to use the port due to this firewall function. In this case, please  
turn off this function temporarily. There are also some port limitations on the net-  
work equipment such as router. Please consult your network administrator.  
Q
A
I cannot make a new program file.  
Check your account of the FTP server. You must have a mode "Write enable" for its  
account.( p.87)  
11ꢂ  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Q&A  
File Converter 1  
Q
A
What kind of image formats can I convert?  
The File Converter 1 enables to convert to the JPEG format from the following  
image format.  
Bitmap format (.bmp)  
JPEG format (.jpeg .jpg)  
Microsoft power point format (.ppt)  
File Converter 2  
Q
A
Sometime I have the white frame images converted by the File Converter  
2?  
It may have images with white frame due to the paper margin of the print driver  
depending on the image data.  
11ꢃ  
LD-NET ORGANIZER  
OWNER'S MANUAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
owNer's MaNuaL Poa-LN02  
iFkM  
saNYo electric Co., Ltd.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Radio Shack Video Gaming Accessories 26 247 User Guide
RCA Clock Radio RP3753 User Guide
RCA Telephone Model 29190C User Guide
RCA Universal Remote RCR6373 User Guide
Reebok Fitness Treadmill RBTL099060 User Guide
Renesas Network Card M3062NT3 RPD E User Guide
Rosewill Computer Drive RHUB120 User Guide
Sagem Cell Phone myX 1 User Guide
Saitek Games ST110 User Guide
Sanyo Battery Charger N 500AC User Guide