GENERAL DATA (AT 230V)  
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)  
POWER V/PH/HZ  
Circuit Ampacity, Min. (A)  
Fuse size, Max.  
230-208/1/60  
30  
30  
COOLING  
Total Capacity  
Sensible Capacity (BTU/H)  
(BTU/H)  
16,500/16,000  
10,390/10,060  
6,110/5,940  
10.0/10.0  
5.3/5.2  
8.0/8.6  
(A)  
Latent Capacity  
SEER  
Dehumidification(Pints/H)  
Amps (A)  
(BTU/H)  
COMPRESSOR  
No. used  
R.L. Amps - L.R. Amps (A)  
Crankcase Heater (W)  
Rotary-Hermetic  
1
7.1 - 52.0  
30  
Power Inputs (W)  
1,810/1,760  
HEATING  
Total Capacity (BTU/H)  
HSPF  
OUTDOOR FAN - TYPE  
Dia. (in.) - No. used  
Type Drive - No. speeds  
No. Poles - RPM (High)  
No. Motors - HP  
Propeller  
15 3/4 - 1  
Direct - 2  
6 - 1,020  
1 - 1/12  
1,190  
18,000/17,600  
6.8/6.8  
8.0/8.6  
1,810/1,760  
1.80/1.47  
7.8  
Amps (A)  
Power Inputs (W)  
Back-up Strip Heater (KW)  
Outdoor Sound Rating (bels)  
CFM (High)  
F.L. Amps. (A)  
0.5  
OUTDOOR COIL – TYPE  
Fin Type - Pipe Type  
Rows - F.P.I.  
Face Area (sq.ft.)  
Tube Size (in.)  
Aluminum Fin & Copper Pipe  
Slit Plate - Inner Riffled  
2 - 15.9  
5.34  
3/8  
FEATURE  
Controls  
Microprocessor  
LCD Wireless type  
IC Thermostat  
ON/OFF, 24 hours  
Built-In  
Manual  
Automatic  
Built-In  
Built-In  
Remote Controller  
Temperature Control  
Timer  
Night Setback  
Air Louve (Horizontal)  
(Vertical)  
Power Failure Automatic Restart  
Self Diagnosis  
Heating/Cooling Automatic Changeover Built-In  
INDOOR FAN - TYPE  
Dia. & Length (in.) - No. used 4 & 30-1  
No. speeds  
No. Poles -RPM (High)  
No. Motors - HP  
CFM (HI/MED/LOW)  
F.L. Amps (A)  
Cross - Flow  
3 & Auto  
4-1,600  
1 - 1/75  
440/380/320  
0.4  
INDOOR COIL – TYPE  
Fin Type - Pipe type  
Rows - F.P.I.  
Face Area (sq. ft.)  
Tube Size (in.)  
Aluminum Fin & Copper Pipe  
Slit Plate - Inner Riffled  
2 - 14.1  
2.08  
3/8  
OPTION  
Refrigerant Line Set  
AP2507BH (20 ft)  
AP2510BH (30 ft)  
AP2515BH (50 ft)  
N/A  
Drain Connection Size (in.)  
1 - 1/4  
Low Ambient Control  
Fresh Air Intake  
Central Remote ON-OFF Control  
Airduct Extension  
Indoor Frame Extension  
Condensate Drain Pump  
Non-Removable Remo-con Bracket  
N/A  
Available  
N/A  
PLB 182  
Available  
Available  
REFRIGERANT  
Lbs. - R22 (O.D. Unit)  
Control  
Connection  
Line Length, Max (ft.)  
Lift difference, Max (ft.)  
R22  
4.25  
Capillary Tube  
Flare  
65  
23  
Line Size - in. O.D. Discharge 1/4  
Line Size - in. O.D. Suction  
5/8  
OPERATING RANGE  
DIMENSIONS (in.)  
H
x
W
x
x
D
Cooling  
Indoor Air  
Intake Temp.  
95 F DB/71 F WB  
67 F DB/57 F WB  
80 F DB/67 F WB  
Outdoor Air  
Intake Temp.  
115 F DB  
Indoor Unit  
-Uncrated 14- 3/16 x 39  
-Crated 18  
Outdoor unit -Uncrated 24-13/16 x 32-11/16 x 12-13/32  
-Crated 28- 3/32 x 39- 5/32 x 16- 9/32  
7-13/16  
x 42-17/32 x 10-23/32  
Maximum  
Minimum  
67 F DB  
75 F DB / 65 F WB  
17 F DB/ 15 F WB  
Heating Maximum  
Minimum  
-
F DB/ - F WB  
WEIGHT  
Net  
INDOOR  
29.8  
37.5  
OUTDOOR  
134.5  
143.3  
(lbs.)  
CERTIFICATION  
Shipping (lbs.)  
Shipping Volume  
(cu.ft.)  
4.8  
10.3  
18KHS22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DIMENSIONAL DATA  
Indoor Unit: KHS1822  
14-3/16  
38-31/32  
7-25/32  
Rear panel  
(Center point of gravity)  
Wireless remote  
control unit  
1-61/64  
2-13/64  
19/32  
Drain hose O.D. 1-1/4  
Narrow tube O.D. 1/4  
5-19/32  
Center of  
tubing hole  
(For right rear)  
Wide tube O.D. 5/8  
Outdoor Unit: CH1822  
21-3/16  
5-3/4  
Air intake  
Air  
intake  
4
15/32 dia. hole  
Check port  
Air discharge  
32-11/16  
1/4 narrow tubing  
service valve  
2-1/4  
1-3/16  
11-7/32  
5/8 wide tubing  
service valve  
2-3/8  
3-3/4  
3/4  
WARRANTY  
Full specific warranty rights, conditions, exclusions and obligations are specified in the  
warranty packed with each products.  
SANYO products are warranted against defects in materials and workmanship for the  
period below;  
LABOR  
30 Days  
N/A  
PARTS  
5 Years  
1 Year  
Compressor  
Other Components  
Because of a policy of continuous product improvements, SANYO reserves the right  
to change specifications and design without notice.  
SANYO FISHER COMPANY  
A Division of SANYO North America Corporation  
21605 Plummer St. Chatsworth, CA 91311  
Phone : (818) 998- 7322  
Fax  
: (818) 701- 4160  
Download from Www.Somanuals.com. All Manuals Search And Download.  

QSC Audio Network Card QE 16 0 User Guide
Radica Games Games 71013 User Guide
Radio Shack Cordless Telephone 43 3549 User Guide
Raymarine Marine GPS System 420 User Guide
RCA CD Player A180 User Guide
RIDGID Metal Detector SR 60 User Guide
Rolls MP3 Player Accessories HR73 User Guide
Samsung DVD Player DVD 1080P9 User Guide
Samsung DVD Player DVD V9700 User Guide
Samsung Projection Television SP 50L3HR User Guide