SUBMITTAL SHEET
SYSTEM
INDOOR/OUTDOOR
AIRCONDITIONING PRODUCTS
09KHS22
09KHS22/CH0922
WALL MOUNTED HEAT PUMP
SS09KHS22-1
PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230/208V)
GENERAL DATA
(At 230V )
COOLING
Total Capacity
Sensible Capacity (BTU/H)
Latent Capacity (BTU/H)
SEER
Dehumidification (Pints/H)
Amps
Power Inputs (W)
HEATING
POWER V/PH/HZ
Circuit Ampacity, Min. (A)
Fuse size, Max.
230 - 208/1/6
15
15
(BTU/H)
9,000/8,800
5,690/5,530
3,310/3,270
10.0/10.0
2.2/2.1
(A)
COMPRESSOR
No. used
R.L. Amps - L.R. Amps (A)
Crankcase Heater
Rotary-Hermetic
1
4.0-30
20W
(A)
4.5/4.6
950/930
Total Capacity
HSPF
(BTU/H)
10,900/10,700
6.8/6.8
4.7/4.8
1,030/980
1.0/0.82
7.0
OUTDOOR FAN - TYPE
Dia. (in.) - No. used
Type Drive - No. speeds
No. Poles - RPM
No. Motors - HP
Propeller
15-3/4 - 1
Direct - 1
6 - 820
1 - 1/38
750
Amps
(A)
Power Inputs (W)
Back-up Strip Heater (KW)
Outdoor Sound Rating(bels)
CFM (High)
F.L. Amps. (A)
0.4
FEATURE
Controls
Remote Controller
Temperature Control
Timer
OUTDOOR COIL - TYPE
Fin Type - Pipe Type
Rows - F.P.I.
Face Area (sq.ft.)
Tube Size (in.)
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffled
2 - 15.9
3.29
3/8
Microprocessor
LCD Wireless type
IC Thermostat
ON/OFF, 24 hours
Built-In
Night Setback
Air Louver (Horizontal)
(Vertical)
Power Failure Automatic Restart
Self Diagnosis
Manual
Manual
Built-In
Built-In
INDOOR FAN - TYPE
Dia. & Length (in.) - No. used
No. speeds
No. Poles -RPM (High)
No. Motors - HP
Cross - Flow
3-17/32 & 24-5/8 - 1
3 & Auto
4-1,450
1 - 1/75
Heating/Cooling Automatic Changeover Built-In
CFM (HI/MED/LOW)
F.L. Amps (A)
220/190/160
0.2
OPTION
Refrigerant Line Set
AP0905BH (15 ft)
AP0907BH (20 ft)
AP0910BH (30 ft)
N/A
N/A
Available
N/A
N/A
Available
Available
INDOOR COIL - TYPE
Fin Type - Pipe type
Rows - F.P.I.
Face Area (sq. ft.)
Tube Size (in.)
Aluminum Fin & Copper Pipe
Slit Plate - Inner Riffled
2 - 14.1
1.63
3/8
Low Ambient Control
Fresh Air Intake
Central Remote ON-OFF Control
Airduct Extension
Indoor Frame Extension
Condensate Drain Pump
Non-Removable Remo-con Bracket
Drain Connection Size (in.)
23/32
REFRIGERANT
Lbs. - R22 (O.D. Unit)
Control
R22
2.91
Capillary Tube
Flare
50
23
1/4
3/8
OPERATING RANGE
Cooling
Connection
Indoor Air
Intake Temp.
Outdoor Air
Intake Temp.
115 F DB
67 F DB
75 F WB/65 F WB
17 F WB/15 F WB
Line Length, Max (ft.)
Lift difference, Max (ft.)
Line Size - in. O.D. Discharge
Line Size - in. O.D. Suction
Maximum 95 F DB/71 F WB
Minimum
Heating Maximum 80 F DB/67 F WB
67 F DB/57 F WB
Minimum
- F DB/ - F WB
DIMENSIONS (in.)
H
x
W
x
D
Indoor Unit - Uncrated 13-19/32 x 31- 1/ 2 x 7- 3/32
- Crated 17- 3/16 x 33- 7/ 8 x 9 -21/32
CERTIFICATION
Outdoor unit -Uncrated 20- 7/8 x 29-17/32 x 11-1/32
-Crated
23- 17/32x 35-13/32 x 13- 7/8
WEIGHT
Net
INDOOR
24.3
OUTDOOR
90.4
(lbs.)
Shipping(lbs.)
28.7
97.0
09KHS22
Shipping Volume (cu.ft.)
3.2
6.7
Download from Www.Somanuals.com. All Manuals Search And Download.
DIMENSIONAL DATA
31-1/2
Indoor Unit: KHS0921, KHS0922
Wireless remote
control unit
2-13/64
19/32
Rear panel
(center point
of gravity)
7-3/32
7-11/64
17-23/32
6-23/32
Center of
tubing hole
5-1/2
Drain hose O.D. 23/32
(for right
1-3/8
O.D. 1/4" narrow tubing
O.D. 3/8" wide tubing
rear)
1-49/64
Check port
Outdoor Unit: CH0921, CH0922
1/4" narrow tubing
service valve
29-17/32
2-1/4
1-3/16 9-27/32
3/8" wide tubing
service valve
4
15/32 dia. hole
Air intake
Air
intake
Air discharge
23-15/16
2-3/8
WARRANTY
Full specific warranty rights, conditions, exclusions and obligations are specified in the
warranty packed with each products.
SANYO products are warranted against defects in materials and workmanship for the
period below;
LABOR
30 Days
N/A
PARTS
5 Years
1 Year
Compressor
Other Components
Because of a policy of continuous product improvements, SANYO reserves the right
to change specifications and design without notice.
SANYO FISHER COMPANY
A Division of SANYO North America Corporation
21605 Plummer St. Chatsworth, CA 91311
Phone : (818) 998- 7322
Fax
: (818) 701- 4160