Cell Type HR-AU
Specifications
Type : Nickel-Metal Hydride Battery
Size : A
Typical
2700mAh
Capacity
1)
Minimum
2450mAh
17.0 mm
Nominal Voltage
1.2V
Charging Current x Time
Fast Charge
Fast Charge
2)
2)
2700 mA x about 1.1h
0°C - 40°C
Charge
Condition
Discharge Condition
0°C - 50°C
50.0 mm
Less than
30days
Ambient Temp.
-20°C - 50°C
-20°C - 40°C
-20°C - 30°C
About 20mΩ(at 1000Hz)
Storage
Condition
Less than
90days
Less than
1year
Internal Impedance
3)
(after discharge to E.V.=1.0V)
Weight
4)
About 40 g
Size
4)
:(Diameter) x (Height)
17.0(D) x 50.0(H) mm
1)Single cell capacity under the following condition.
Charge : 270mA×16h, Discharge : 540mA(E.V.=1.0V) at 20°C
2)Use recommended charging system.
3)After a few charge and discharge cycles under the above 1) condition.
4)With tube.
D
H
17.0 mm
50.0 mm
Dimensions
(with tube)
Typical Characteristics
Charge
Discharge
1.6
1.8
1.7
1.6
1.5
1.4
1.3
Charge : 210mA x 16h
Rest : 1h
1.5
Discharge : 420mA, 2100mA, 4200mA (E.V.=1.0V)
Ambient Temp. : 20°C
0°C
1.4
20°C
420mA
40°C
1.3
1.2
1.1
1.2
2100mA
Charge : 2100mA (-∆V=10mV)
4200mA
1.0
Ambient Temp. : 0°C,20°C,40°C
1.1
1.0
0.9
0
10
20
30
40
50
60
70
80
90
0
500
1000
1500
2000
2500
3000
Charge Time (min)
Discharge Capacity (mAh)
Download from Www.Somanuals.com. All Manuals Search And Download.
|
RadioLAN Network Router WNR834B User Guide
Radio Shack Home Security System Two Zone Burglar Alarm System User Guide
Radio Shack Two Way Radio 21 1901 User Guide
RCA Microcassette Recorder RP5032 User Guide
RCA Stereo Receiver STA 3850 User Guide
Roberts Radio Clock Radio CR9901 User Guide
Samsung Cell Phone T939 User Guide
Samsung Graphics Tablet GT P7500 User Guide
Samsung Switch MCC8 User Guide
Sanus Systems Gas Heater AFDV User Guide